Loading...
07-3170 (CSCS) Title 24TITLE 24 REPORT Title 24 Report for: Jefferson Square Retail shops Building 3 4+e>25, Jefferson Street La Quinta , CA Project Designer: 1411 Fifth St., Suite 300 Santa Monica, CA 90401 310-394-2623 Report Prepared By: Bradley Severson AMPE, INC 600 W. Broadway #250 Glendale, CA 91204 (818) 265-9720 Job Number: Date: 8/11/2008 ?-'21 - 0 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION MA-rr: �' III 103 13YF," �#7.-1IE) AUG 2 5 2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 5424 t F% -F I CF -1 I f ' TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 15 .Form LTG-7-C.�Room Cavity Ratio Worksheet 16 Form LTG -MM Lighting Mandatory Measures 17 Form MECH-MM Mechanical Mandatory Measures 18 HVAC System Heating and Cooling Loads Summary 20 Lighting Inspection Checklist 25 EnergyPro 4.4 by EnergySoft Job Number: User Number: 5424 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 Of 3 PERF -1 PROJECT NAME Jefferson Square Retail shops Building 3 This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE 8/11/2008 PROJECT ADDRESS Jefferson Street La Quinta DOCUMENTATION AUTHORSIGNATURE F_ PRINCIPAL DESIGNER -ENVELOPE TELEPHONE 310-394-2623 Building Permit # I DOCUMENTATION AUTHOR AMPS, INC TELEPHONE (818) 265-9720 Checked by/Date Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHORSIGNATURE DATE OF PLANS 12/18/07 BUILDING CONDITIONED FLOOR AREATE 6,667 Sq.Ft. 9?/111013 CLIMA ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION 0 ADDITION F—] EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHORSIGNATURE DATE BradleySeverson 7 9?/111013 The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 0 El 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1, LTG -2 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATOR LIC. N . DATE Sothol Roeun /� MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE Bradley Severson EnergyPro 4.4 by EnergySoft - User Number: 5424 Job Number: Pane:3 of 25 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PER NAME DATE Jefferson Square Retail shops Building3 8/11/2008 :1 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard ENERGY COMPONENT Design Space Heating 0.33 Space Cooling 435.17 Indoor Fans 45.41 Heat Rejection 0.00 Pumps & Misc. 0.00 Domestic Hot Water 16.40 Lighting 187.30 Receptacle 87.43 Process TOTALS: 772.03 Percent better than Standard: Proposed Design 0.03 233.50 46.93 o.00 0.00 16.40 187.30 87.43 571.58 26.0% Compliance Margin i StanOaM .Proposed 0.31 GP-H-I:V S SP -C - *V' kd-F- HWRejaction '"°0`a"'°° 0 30 60 00 120150 180.210 240 270 300 330 380 300 420 keiWsq>t-yr 201.67 -1.52 0.00 0.00 0.00 0.00`°°` 200.46 ( 26.0% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (N)Odeg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 6,667 sqft. 1 0 sqft. 6 6,667 sqft. 5 Natural Gas Orientation Front Elevation N Left Elevation (E) Rear Elevation s Right Elevation (W)l Total Roof Gross Area sqft. sqft. sqft. sqft. sqft. sqft. Glazing Area Glazing sqft. sqft. sqft. sgft. sqft. sqft. Ratio 1,610 80 5.0% 420 192 45.7% 1,120 640 57.1% 840 2001 23.8% 3,990 1,112 6,667 E::::� 0.0% Standard Proposed Lighting Power Density 1.700 W/sgft. 1.700 W/sgft. Prescriptive Env. Heat Loss 1,146 Btu/h 779 Btu/h Prescriptive Env. Heat Gain 137,575 Btuth-F 101,302 Btu/h-F Remarks: Run Initiation Time: 08/11/08 14:03:33 Run Code: 1218492213 EnergyPro 4.4 by Energysoft User Number: 5424 Job Number: Page:4 of 25 t ' � PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Jefferson Square Retail shops Building 3 DATE 8/11/2008 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Allowed LPD Proc. Loads I (W/sf) Area Tailored (W/S31 (W/S4 SHOP A SHOP A Retail Sales, Wholesale 1,214 '1.70 Shop B SHOP B Retail Sales, Wholesale 1,199 '1.70 Shop C SHOP C Retail Sales, Wholesale 1,210 '1.70 Shop D SHOP D Retail Sales, Wholesale 1,691 "1.70 Shop E SHOP E Retail Sales, Wholesale 1,353 '1.70 Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C (items marked with asterisk, see LTG -2 -C by others) (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST ;nu tocai emorcement agency snowa pay special attention to the items specified in this checklist. These items require special written justification nd documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System 'Trane YHC048AY includes an Economizer. This system has a cooling output < 75,000 Btuh or a supply cfm < 2500. The HVAC S stem 'Trane YHC048AY is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System 'Trane YHC048AY includes Demand Control Ventilation per Standards Section 121. The HVAC System 'Trane YHC060AY includes an Economizer. This system has a cooling output < 75,000 Btuh or a supply cfm < 2500. The HVAC System 'Trane YHC060AY is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System 'Trane YHC060A3" includes Demand Control Ventilation Der Standards Section 121. i no exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized S UAVC EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Paae:5 of 25 1 CERTIFICATE OF COMPLIANCE ENV -1-C (PROJECT NAME DATE L Jefferson Square Retail shops Building 3 8/11/2008 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Azm. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Roof 1.21 0.032 R-30 R-0.0 0 0 New 01-A17 SHOP A 2 Wall 256 0.074 R-19 R-0.0 0 90 New 09-A5 SHOP A 3 Door 24 0.700 None R-0.0 0 90 New 28-A2 SHOP A 4 Wall 12C 0.074 R-19 R-0.0 180 90 New 09-A5 SHOP A 5 Wall 640 0.074 R-19 R-0.0 270 1 90 New 09-A5 SHOP A 6 Roof 1,19 0.032 R-30 R-0.0 0 1 0 New 01-A17 SHOP B 7 Wall 250 0.074 R-19 R-0.0 0 90 New 09-A5 SHOP B 8 Door 24 0.700 None R-0.0 0 90 New 28-A2 SHOP B 9 Wall 120 0.074 R-19 R40 180 90 New 09-A5 SHOP B 10 IRoof 1,210 0.032 R-30 R-0.0 0 0 New 01-A17 SHOP C 11 Wall 250 0.074 R-19 R-0.0 0 90 New 09-A5 SHOP C 12 Door 24 0.700 None R-0.0 0 1 90 New 28-A2 SHOP C 13 Wall 120 0.074 R-19 R-0.0 180 90 New 09-A5 SHOP C 14 Roof 1,691 0.048 R-19 R-0.0 0 0 New 01-A14 SHOP D 15 Wall 250 0.074 R-19 R-0.0 0 90 New 09-A5 SHOP D 16 Door 24 0.700 None R-0.0 0 90 New 28-A2 SHOP D ll 12 0.074 R-19 R-0.0 180 90 New 09-A5 SHOP D of 1,35 0.048 R-19 R-0.0 0 0 New 01-A14 SHOP E ll f 41 0.074 R-19 R-0.0 0 90SHOP E ll 22 0.074 R-19 R-0.0 90 90 New 09-A5 SHOP E N, E, A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's protect office during construction and in the building rnaneners ntsr , after r,0nStnfit,,,, # lTvpe Area U -Fac' SHGC' Act. Azm. Cond. Stat. Glazing Type Location/ Comments 1 lWindow Rear S 160 0.280 NI -1 0.38 COG 180 New PPG SOLARBAN 60 2 CLEAR SHOP A 2 Window Right W) 200 0.280 NI -1 0.38 COG 270 New PPG SOLARBAN 60 2) CLEAR SHOP A 3 Window Rear S 160 0.280 NI -1 0.38 COG 180 New PPG SOLARBAN 60 2 CLEAR SHOP B 4 Window Rear S 160 0.280 NI -1 0.38 COG 180 New PPG SOLARBAN 60 2 CLEAR SHOP C 5 Window Rear S 160 0.280 NI -1 0.38 COG 180 New PPG SOLARBAN 60 2 CLEAR SHOP D 6 Window Front N 80 0.280 NI -1 0.38 COG 0 New PPG SOLARBAN 60 2 CLEAR SHOP E 7 Window Left E) 192 0.280 NI -1 0.38 COG 90 New PPG SOLARBAN 60 2 CLEAR SHOP E MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES (1) U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Riaht Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 8.0 16.5 10.0 0.1 10.0 10.0 2 None 0.76 8.0 16.5 10.0 0.1 10.0 10.0 3 None 0.76 8.0 15.0 10.0 0.1 10.0 10.0 4 None 0.76 8.0 15.0 10.0 0.1 10.0 10.0 5 None 0.76 8.0 15.0 10.0 0.1 10.0 10.0 6 Woven Sunscreen 0.30 8.0 10.0 4.0 0.1 4.0 4.0 7 Woven Sunscreen 0.30 8.0 29.0 2.0 0.1 2.0 2.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 16 and contains an enclosed space with floor area greater than 25,000 U, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.6 WK. See Section 143(c). If this box Is checked, ENV -4-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Paae:6 of 25 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C PROJECT NAME M Jefferson Square Retail shops Building3 8/11/2008 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C). ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 11,334 ALTERNATE COMPLIANCE Q PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROLTYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if NOTE TO FIELD NOTES TO FIELD - For Buildinq Department Use Only Run Initiation Time: 08/11/08 14:03:33 Run Code: 1218492213 EnergyPro 4.4 by EnergySok User Number: 5424 Job Number: Pagel of 25 INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 11,334 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 11.334 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C). ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 11,334 ALTERNATE COMPLIANCE Q PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROLTYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if NOTE TO FIELD NOTES TO FIELD - For Buildinq Department Use Only Run Initiation Time: 08/11/08 14:03:33 Run Code: 1218492213 EnergyPro 4.4 by EnergySok User Number: 5424 Job Number: Pagel of 25 CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1-C PROJECT NAME Jefferson Square Retail shops Building 3 DATE 8/11/2008 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting . system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Descri tion Test Performed B ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page:8 of 25 1 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and Weratino and maintenance information meet the requirements of Section 10-103th1 and Title 24 Part R STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 R2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant Now chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable Now chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page:9 of 25 N O r tf co CL I N oo W a 0 W Q z M m CI) Q O N M N cu c O CO) tE N It v oc1r) ao ti IT o L c1r) J co O Q' H Z U CI) a. M M M w M LO Cfl O rl- Installed O O O M CUO Watts N N N N N (G x 1) t� T Number of M Luminaires d CEC N = Default? C Wafts per Luminaire Number of li Ballast per Luminaire Wafts W per N Lamp M R m Number of 0 Lamps per 1 CLE Luminaire M J U Lamp Type C. CD C> C, 0 ca to M M M O N N N N N O MO T M V (=j N r .N- N r I (D •C •E ~ O O O O .O J Q Q Q Q Q v v v v v M v m v m v (`o v m v . in3i�;cn3v�3tn3 _ m E M z ' It v oc1r) o J O Z _m JO O v G W H � c1r) J co O Q' H Z U CI) a. M M M w a d W a CL E J ` u. C7 v J o H m ►_- U Q J O Z _m JO O v G W H � C7 Z Dw m J co O Q' H Z U 0 Q a. L: a E z' 0 ;'T Do N D A M E E z' a v AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 SYSTEM' FEATURES ITEM OR SYSTEM TAG(S) Number of Systems AIR SYSTEMS, Central or Single Zone SHOP A Shop B Shop C 1 1 1 T-24 MANDATORY MEASURES Section Reference on Plans or Specification Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 82% AFUE 82% AFUE 82% AFUE 112(a) 15.0 SEER / 12.0 EER 15.0 SEER / 12.0 EER 15.0 SEER / 12.0 EER 112(b) n/a n/a n/a 112(c), 115 a n/a n/a n/a 121(b) No No No 121 b 427 cfm 402 cfm 402 cfm 121 c No No No 121 c Yes Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122ffi Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-8.0 R-8.0 R-8.0 144 a & b n/a n/a n/a 144 a & b 64,000 btuh 64,000 btuh 64,000 btuh 144 a & b n/a n/a n/a 144 a & b 46,928 btuh 46,695 btuh 46,696 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c) 144 c No No No 144 d No No No. 144 a Fixed Tem (Integrated) Fixed Tem (integrated) Fixed Tem (Integrated) 144 Constant Temp Constant Temp Constant Tem 144(f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page: 11 of 25 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C (PROJECT NAME I DATE Jefferson Square Retail shops Building 3 8/11/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone Shop D Shop E 2 1 Reference on Plans or Specification 1 112(a) 82% AFUE 82% AFUE 112(a) 15.0 SEER / 11.0 EER 15.0 SEER / 12.0 EER 112(b) n/a n/a 112(c), 115(a) n/a n/a 121(b) No No 121 b 564 cfm 509 cfm 121 c No No 121 c Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required 122 Auto Auto 122( n/a n/a 123 124 R-8.0 R-8.0 144 a & b n/a n/a 144 a & b 128,000 btuh 64,000 btuh 144 a & b n/a n/a 144 a & b 113,977 btuh 47,538 btuh 144 c Constant Volume Constant Volume 144 c 144 c No No 144 d No No 144 a Fixed Tem Non-Inte Fixed Tem (Integrated) 144 Constant Ternp Constant Tem 144(l) Constant Temp Constant Temp 144 k No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. L _ EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Paoe:12 of 25 1 MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 PRESCRIPTIVE REHEAT LIMITATION Section 144(d)) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L I M N ZONE/SYSTEM 0 o D� TAa v° NQ a c din ��T ° 3 o 3 W X Dn -nOQ m 3 Z �c is '°eD 0 c 0-'0 Rm-n ' 3 `c 03 m�� Xn3 "' 3 vim A 0X C °, < D p n m T.'.N 3 D 0 NCD O o' n00 TNS' 3 ii r0o 3 yX . A 7C0 °° c w3o3i 07X n=° L y N� � 3 m ' -yw D 1 SHOP A 1,214 0.25 304 28.5 15.0 427 427 427 SHOP A Total 427 427 SHOP B 1,199 0.25 300 26.8 15.0 402 402 402 Shop B Total 402 402 SHOP C 1,21C 0.25 302 26.8 15.0 402 402 402 Shop C Total 1 402 402 SHOP D 1,691 0.25 423 37.6 15.0 564 564 564 Shop D Total 564 564 SHOP E 1,353 0.25 338 33.9 15.0 509 509 509 Shop E Total 509 509 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REQ'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply cfm Fan CFM x 30%; or K Condition area ft. sq.) x 04 cfm/ft. sq.; or L Maximum of Columns H, J. K, or 300 cm M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page: 13 of 25 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Jefferson Square Retail shops Building3 DATE 8/11/2008 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 1QHW / BOILER SUMMARY Energy Standby TANK INSUL.I Rated Vol. Condition Factor Loss or Ext. System Name System Type Distribution Type Qty Input (Gals.) Status or RE Pilot R -Val. MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Add 1/2" Control # HP . Type In Plenum Outside Buried Insulation CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name S stem T e Qty Output kW Eff. Outout Efficiencv Status Economizer Type Trane YHC048A3 Packaged DX 4 64,000 0.0 82%AFUE 49,800 15.0 SEER / 12.0 EER New Fixed Temp (Integrate( ) Trane YHC060A3 Packaged DX 2 64,000 0.0 82% AFUE 62,400 15.0 SEER / 11.0 EER New Fixed Temp (Non-Inte ) ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE Jefferson Square Retail shops Buildinq 3 8/11%2008 DESCRIPTION Designer Enforcement ❑X §118(a) Installed Insulating Material shall have been certified by the manufacturer to .comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X] § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. R§ 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. X] § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). X] § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. 0 §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page: 15 of 25 A B C D E F Room Name Task/Activity Description Room Length (L) ft) Room Width (W) (ft Room Cavity Height (H) (ft) Room Cay. Ratio 5xHx(L+W) /(LxW) A B C D E F Room Name Task/Activity Description Room Area (A) (so Room Perimeter (P) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A LIGHTING MANDATORY MEASURES LTG - PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 DESCRIPTION Designer Enforcement ❑X § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. FX]§ 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X❑ § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. X] § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniformreduction of lighting within the room. R§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. X] § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page: 17 of 25 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies §11 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. 0 §115(a) Fan type central furnaces shall not have a pilot light. 0 §123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124 Air handling duct systems shall be installed and -insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls §122(e) Each space conditioning system shall be installed with one of the following: a§122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or a§122(e)1 B An occupancy sensor to control the operating period of the system; or ❑X §l22(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. XJ §122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. X❑ §122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ZNJ §122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees.F within which the supply of heating and cooling is shut off or reduced to a minimum. X❑ §122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. 0 §112(b) Heat pumps shall be installed with controls to prevent electric resistance - supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page: 18 of 25 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM (PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 Description Designer Enforcement Ventilation FX §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. , §122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. §121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑ §I21(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or §121(f)4 Another method approved by the Commission. Service Water Heating Systems FX]. §113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page:19 of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 SYSTEM NAME FLOOR AREA SHOP A 1,214 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 52.7 Cooling System Output per System 49,800 Total Output (Btuh) 49,800 Total Output (Tons) 4.2 Total Output (Btuh/sqft) 41.0 Total Output (sgft/Ton) 292.5 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.32 Airflow (cfm/Ton) 385.5 Outside Air (%) 26.7 Outside Air (cfm/sgft) 0.35 Note: values above gi HEATING SYSTEM 26.0 of Outside Air 427 cfm 69.6 of at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM Sensible 2,056 35,009 5,694 360 13,404 0 1,750 670 0 0 427 16,349 4,767 427 19,819 1,353 -1,353 1,7501 670 56,21:2E::;;1 Trane YHC048A3 46,928 0 Total Adjusted System Output 46,928 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Jul 5 pm 58.0 of i 105.0 of Heating Coil Tem at Supply Fan 1600 cfm 64,000 64,000 Jan 12 am 105.8 of -� Supply Air Ducts 105.4 of ROOMS 70.0 of �% Return Air Ducts 4 112.0 / 77.9 of 85.6 / 68.6 of . 59.0 / 57.6 of 59.8 / 57.9 of � J � Outside Air 427 cfm 76.0/64.7 of Cooling Coil O Supply Air Ducts Supply Fan 60.8 / 58.3 of 1600 cfm 56.7% R.H. ROOMS 75.0 / 64.4 of Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Paae:20 of 25 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 SYSTEM NAME FLOOR AREA Shop B 1,199 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 53.4 Cooling System Output per System 49,800 Total Output (Btuh) 49,800 Total Output (Tons) 4.2 Total Output (Btuh/sgft) 41.5 Total Output (sgft/Ton) 288.9 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.33 Airflow (cfm/Ton) 385.5 Outside Air (%) 25.1 Outside Air (cfm/sgft) 0.33 Note: values above given at ARI conditions 26.0 OF Outside Air 402 cfm 69.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 45 037 9,8811 Trane YHC048A3 46,695 0 Total Adjusted System Output a6,695 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Jul 2 pm PSYCHROMETRICS (Airstream Tel 58.8 OF 105.0 of Heating Coil TOOLING SYSTEM PSYCH 12.0 / 77.9 of Outside Air 402 cfm 75.8/64.6 of at Time of 64,000 64,000 Jan 12 am 105.8 of O Supply Air Ducts Supply Fan 105.6 of 1600 cfm ROOMS 70.0 of Return Air Ducts I res at 84.9 / 68.3 of. 59.0 / 57.7 OF Cooling Coil Q Supply Fan 1600 cfm 59.8 / 58.0 of Supply Air Ducts 60.5 / 58.2 of 56.6% R.H. ROOMS 75.0 / 64.3 of �..�. ....� A:_ r%.._.. EnergyPro 4.4 by Energysoft User Number: 5424 Job Number:. Page: 21 of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 SYSTEM NAME FLOOR AREA Shop C 1,210 EATING SYSTEM PSYCHROMETRICS J&ELt 26.0 OF 58.8 OF Outside Air 402 cfm 69.8 OF 12.0 / 77.9 OF Outside Air 402 cfm 75.8/64.6 °F . Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,512 25,754 5,355 188 6,987 0 1,288 349 0 0 402 15,492 4,526 402 18,719 1,353 -1,353 1,288 1 349 45 174 9 881 25 052 Trane YHC048A3 46,696 0 64,000 Total Adjusted System Output46,696 0 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 2 pm Jan 12 am 105.0 OF Heating Coil PSYCHROMETRICS Supply Fan 1600 cfm 105.8 OF Supply Air Ducts 105.6 OF ROOMS 70.0 OF h Return Air Ducts i 84.9 / 68.3 OF . 59.0 / 57.7 OF, Cooling Coil Supply Fa 1600 cfm 59.8 / 58.0 of Supply Air Ducts Fan h Return Air Ducts 11 60.6/58 . 2 of 56.6% R.H. ROOMS 75.0 / 64.3 OF EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Paae:22 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jefferson Square Retail shops Building 3 8/11/2008 SYSTEM NAME FLOOR AREA Shop D 1,691 :ATING S 26.0 OF Outside �� 564 cfm 69.9 OF 112.0 / 77.9 of >—:11 Outside Air 564 cfm 75.5/64.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 2,103 35,803 7,522 224 8,341 0 1,790 417 0 0 564 21,934 6,815 564 26,352 2,707 -2,707 1,790 417 64.0 14 338 32 821 Trane YHC060A3 113,977 0 128,000 Total Adjusted System Output 113,977 0 128,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 2 pm Jan 12 am RIGS (Airstream Temperatures 63.0 of ® 105.0 of Heating Coil Supply Fan 3600 cfm 105.7 of -� Supply Air Ducts 105.6 of ROOMS 70.0 of �% Return Air Ducts 4 ratures 81.2/66.7OF M 59.0/57.8OF Cooling Coil Supply Fan 3600 cfm 59.7 / 58.1 of Supply Air Ducts 60.2 / 58.3 of 55.7% R.H. ROOMS 75.0 / 64.1 of h Return Air Ducts 'I EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Paae:23 of 25 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jefferson Square Retail shops Buildin 3 8/11/2008 SYSTEM NAME FLOOR AREA Shop E 1,353 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sqft) 47.3 Cooling System Output per System 49,800 Total Output (Btuh) 49,800 Total Output (Tons) 4.2 Total Output (Btuh/sqft) 36.8 Total Output (sgft/Ton) 326.0 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.18 Airflow (cfm/Ton) 385.5 Outside Air (%) 31.8 Outside Air (cfm/sgft) 0.38 Note: values above given at ARI conditions 26.0 of )� Outside Air 509 cfm 69.6 of 112.0 / 77.9 of Outside Air 509 cfm 76.0/64.8 of ETRICS 55.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM TSensible Latent CFM I Sensible 58.2 12 233 35 998 Trane YHC048A3 47,538 0 64,000 Total Adjusted System Output 47,538 0 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 2 pm Jan 12 am 'earn Temperatures at Time of Heatina Peak) 105.0 of Heating Coil Supply Fan 1600 cfm 105.8 of —� Supply Air Ducts 105.4 of ROOMS 70.0 of h Return Air Ducts 4 res at Ti 87.5 / 69.3 of M 59.0/57.60F Cooling Coil Supply Fan 1600 cfm 59.8 / 57.9 of Supply Air Ducts 60.8 / 58.2 of 57.2% R.H. ROOMS 75.0 / 64.5 of h Return Air Ducts 4 EnergyPro 4.4 by Energysoft User Number: 5424 Job Number: Paoe:24 of 25 ft*, LIGHTING INSPECTION CHECKLIST LTG -11 (PROJECT NAME INSPECTION DATE f Jefferson Square Retail shops Building3 8/11/2008 FIXTURE CODE TYPE DESCRIPTION LAMP TYPE LAMP QUANT. NUMBER OF FIXTURES WATTS PER FIXTURE FIELD NOTES EnergyPro 4.4 by EnergySoft User Number: 5424 Job Number: Page:25 of 25