0211-002 (CONR) Title 24
TITLE 24 REPORT I Title 24 Report for: The Hideaway Gate House 53-000 Jefferson Street La Quinta, CA 92253 Project Designer: BBG Architects 20-371 Irvine Ave. Ste. 120 Santa Ana Heights, CA 92707-5651 (714) 434-2506 1 Report Prepared By: Gina Rose BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATEo�`oZ�J•o3 BY S'r Job Number: Date: 12/23/2002 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is R authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. ' This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number 3665 TABLE OF CONTENTS Cover Page 1 l Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 13 Form LTG -4 Tailored LPD Summary and Worksheet 14 Form LTG -5 Room Cavity Ratio Worksheet 15 Form LTG -MM Lighting Mandatory Measures 16 Form MECH-MM Mechanical Mandatory Measures 17 HVAC System Heating and Cooling Loads Summary 19 Room Load Summary 20 Room Heating Peak Loads 21 Room Cooling Peak Loads 22 Room Cooling Coil Loads .24 EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -T ROJECT NAME The Hideaway Gate House ;DATE 12/23/2002 PROJECT ADDRESS 6, of the State Building Code. This certificate applies only to a Building using t p Ormance compliance approach. 53-000 Jefferson Street La Quinta DATE OF PLANS PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # i BBG Architects (714) 434-2506 PHASE OF CONSTRUCTION DOCUMENTATION AUTHOR BREEZE AIR CONDITIONING TELEPHONE (760) 346-0855 Checked by/Date ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, Enforcement Agency Use GENERAL INFORMATION 6, of the State Building Code. This certificate applies only to a Building using t p Ormance compliance approach. DOCUMENTATION AUTHOR DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 1,01 1Sq.Ft. CLIMATE ZONE i 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION 0 ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using t p Ormance compliance approach. DOCUMENTATION AUTHOR SIGNAT E DAT Gina Rose o2 G 2 - The The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. F] F ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE BBG Architects LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 Required Fo7q PRINCIPAL MECHANICAL DESIGNER - NAME SIGNAT R[4,, — LIC. NO. DAT Breeze Air ConditioningI /(p S Q L EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:3 of 25 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 DATE The Hideaway Gate House 12/23/2002 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r ENERGY COMPONENT Standard Design ' Proposed Design Compliance Margin M sraodird Proposed Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle .Process TOTALS: 2.67 2.37 0.30°"-"9 }, 10 20� 30.40 50,-. 6 60 ke,WsQ"_Y` 67.95 54.01 13.95 � 22.26 24.04 -1.78 1nOoafFo 0.00 0.00 0.00 0.00 0.00 0.00 10.09 10.09 0.00 °^^ 38.28 47.48 -9.20 25.52 25.52 0.00 0 h 0.00 0.00 0.00 166.77 163.50 3.26 BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones West 270 deg Conditioned Floor Area 1,011 sqn. Unconditioned Floor Area o sgft. Conditioned Footprint Area 525 sgft. 1 1 1 Orientation Front Elevation (West) Left Elevation (North) Rear Elevation (East) Right Elevation (south) Total Roof Gross Area sgft. sgft. sgft. sgft. sgft. sgft.sgft. Glazing Area Glazinq sgft. sgft. sqn. sgft. sgft. Ratio 313 46 14.7% 680 84 12.4% 313 22 7.0% 680 69 10.1% 1,986 221 542 OA% Standard Proposed Lighting Power Density 1.300 W/sgft. 1.614 W/sgft. Prescriptive Env. Heat Loss 288 303 Prescriptive Env. Heat Gain 28,545 31,417 Remarks: Run Initiation Time: 12/23/02 12:34:31 Run Code: 1040675671 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: PageA of 25 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustificatior and documentation submitted. cei.a The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. 0, Authorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:5 of 25 1 PROJECT NAME The Hideaway Gate House 7DATE 12/23/2002 ONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (W/sf)t Port. Ctrl. LPD Credits (W/sf)1 (W/sf)2 Tailored Proc. Loads (Wlsf) LPD (W/sf) 3 HVAC -1 Gate House Office 1,011 1.414 0.200 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustificatior and documentation submitted. cei.a The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. 0, Authorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:5 of 25 1 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME The Hideawav Gate House DATE 12/23/2002 PAQUESURFACES Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 24 0.850 0 # Surface Type Framing Type Act. Area U -Fac. Azm. Tilt Solar Gains Y/N Form 3 Reference Location / Comments 1 IRoof lWood 542 0.028 0 0 1X11 I R-38 Roof R.38.2x14.16 Gate House 2 Wall Wood 548 0.059 0 90 X I I R-21 Wall W.21.2x6.16 Gate House 3 Door None 24 0.387 0 90 IX I I Solid Wood Door Gate House 4 Door None 24 0.387 0 90 IX I I Solid Wood Door Gate House 5 Wall Wood 291 0.059 90 90 IX I R-21 Wall W.21.2x6.16 Gate House 6 Wall Wood 611 0.059 180 90 1 X R-21 Wall W.21.2x6.16 Gate House 7 lWall lWood 267 0.059 270 90 IX R-21 Wall W.21.2x6.16 Gate House 8 Floor Wood 56 0.034 0 180 X R-30 Floor F.30.2x10.16 Gate House EXTERIOR SHADING # I Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. Hat. Right Fin Dist. Len. H t. 1 None 0.76 8.0 3.0 6.0 0.1 6.0 6.0 2 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 3 None 0.76 4 None 0.76 5 None 0.76 6 None 0.76 7 1 None 0.76 8 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 9 None 0.76 4.5 5.0. 10.0 0.1 10.0 10.0 10 None 0.76 4.5 5.0 10.0 0.1 10.0 10.0 11 None 0.76 12 None 0.76 FENESTRATION SURFACES Site Assembled Glazing U L,necK oox it buuaing is - Iuu,uuu sqtt of crA ana - 10,000 sqtt vertical glazing then NFRC Certification is required. Follow NFRC 100 -SR Procedures and suhmit NFRC I ahel r:artifirata Fnrm # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 24 0.850 0 0.70 Double Metal Clear Default ate House 2 Window -Window 24 0.850 0 0.70 Double Metal Clear Default ate House F3 24 0.850 0 0.70 Double Metal Clear Default ate House 4 Window 6 0.870 0 0.70 Double Metal Clear Default ate House 5 Window 6 0.720 0 0.73 Double Metal Clear Default ate House 6 Window 6 0.720 90 0.73 Double Metal Clear Default ate House 7 Window 16 0.870 90 0.70 Double Metal Clear Default ate House 8 Window 24 0.850 180 0.70 Double Metal Clear Default ate House 9 Window 22 0.870 180 0.70 Double Metal Clear Default ate House 10 Window 22 0.870 180 0.70 Double Metal Clear Default ate House 11 Window 30 0.720 270 0.73 Double Metal Clear Default Gate House 12 Window 16 0.870 270 0.70 Double Metal Clear Default Gate House EXTERIOR SHADING # I Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. Hat. Right Fin Dist. Len. H t. 1 None 0.76 8.0 3.0 6.0 0.1 6.0 6.0 2 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 3 None 0.76 4 None 0.76 5 None 0.76 6 None 0.76 7 1 None 0.76 8 None 0.76 8.0 3.0 10.0 0.1 10.0 10.0 9 None 0.76 4.5 5.0. 10.0 0.1 10.0 10.0 10 None 0.76 4.5 5.0 10.0 0.1 10.0 10.0 11 None 0.76 12 None 0.76 Run Initiation Ti • 12/23/02 12:34:31 Run Code: 1040 7567 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 25 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 PROJECT NAME DATE The Hideaway Gate House 12/23/2002 I AMPS I PAI i ACTc II Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp DESCRIPTION # (Lamp + Ballast Total I Watts # Watts 65w Recessed Incandescent 65W 1 65 No Ballast 22 65.0 1,430 CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTETO FIELD TYPE # OF LUMINAIRES NOTES TO FIELD - For Buildin-g Department Use Only I - Run Initiation Time: 12/23/02 12:34:31 Run Code: 1040675671 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: Page:7 of 25 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 1,430 • Meets Total 1,430 202 ❑ Efficacy and Control Requirement of§130(c) Portable Lighting (From LTG -1) ❑ Control Requirements of§131ff) Less Control Credit Watts (From LTG -3) 1,632 Adjusted Actual Watts MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION NOTE TO FIELD CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTETO FIELD TYPE # OF LUMINAIRES NOTES TO FIELD - For Buildin-g Department Use Only I - Run Initiation Time: 12/23/02 12:34:31 Run Code: 1040675671 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: Page:7 of 25 LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 PROJECT NAME DATE The Hideaway Gate House 12/23/2002 TABLE 1A - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET FB] n n ROOM # DEFAULT AREA OR ZONE ID /s ft SF TOTAL WATTS B X C Gate House 0.2 1,011 202 1,011 202 TOTAL 1,011 202 TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET FA] a 0 0 0 0 0 LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID nasrrintinn FIXT. FIXTl1RF ISFI ARFAR in v m Ir . m 0. ROOM # TOTAL AREA OR ZONE ID (SF) Designer needs to provide detailed documentation that the lightin level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1 +1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 1,011 202 Run Initiation Time: 12/23/02 12:34:31 Run Code: 1040675671 L EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:8 of 25 r- -,I L - -A CERTIFICATE OF COMPLIANCE Performance MECH-11 PROJECT NAME The Hideawav Gate House SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET - COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS DHW Heater I HVAC -1 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Gas Fired 78% Standard Gas 50 gal or Less n/a n/a Yes Yes n/a n/a n/a n/a n/a Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 202 cfm Heat Pum 7.80 HSPF Split DX 12.8 SEER / 11.1 EER LENNOX HP26- 048/CB30M-65 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No DATE 12/23/2002 CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/ COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPERI ECONOMIZER I O.A. CFM W1r;N FFF1rriFurv? I B: Air Balance I A: Auto A: Air lEnter Outdoor Air PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPAT C: Outside Air Cert. G: Gravity M: Out. Air Measure D: Demand Control N: Natural Water CFM. Not Required Note: This shall be n : Economizer less than Col. H on ntrol See Section MECH-3. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:9 of 25 1 ]MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME IAa:NA►Ion [IMP►9:I:IE.y11IT, ld,/ 1:111 DL•1 CENTRAL SYSTEM FAN SUMMARY SUPPLY Efficiency Tons j PUMPS I j Motor Location ' Equipment Name I Equipment Type Qty. Tot. Qty JGPM CFM BHP Motor Eff. I Drive Eff. i Pump Control Constant Volume Draw -Through 1,600 0.50 77.0% 97.0% none QHW / BOILER SUMMARY Energy Factor or Recovery Efficiency Standby Loss or Pilot TANK INSUL. Ext. R -Val. System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Standard Gas 50 gal Or Less Small Gas Standard 1 40,000 50 0.52 n/a 12 CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Q Output Aux. kW I Eff. Output Sensible Efficiency Economizer Type LENNOX HP26- 048/CB30M-65 Split DX 1 45,600 0.0 7.80 HSPF 49,200 37,88412.8 SEER / 11.1 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY U FAN System Name Fan Type Motor Location CFM BHP Motor Eff. I Drive Eff. CFM BHP Motor Eff. Drive Eff. LENNOX HP26- 048/CB30M-65 Constant Volume Draw -Through 1,600 0.50 77.0% 97.0% none I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:10 of 25 I ]MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME The Hideaway Gate House DATE 2/23/2002 ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL FAN BASEBOARD Zone Name System Type Oty. Min. CFM Ratio Reheat Coil CFM BHP Motor Eff. Drive Eff. Type Output Type DeET— EXHAUST FAN SUMMARY Room Name Q . CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM BHP Motor Eff. Drive Eff. Run Initiation Time: 12/23/02 12:34:31 Run Code: 1040675671 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 11 of 25 MECHANICAL VENTILATION MECH-3 PROJECT NAME The H a Gate House a a a AREA BASIS COND. MIN. AREA CFM CFM (SF) PER SF (B x C) 1,011 0.15 152 DATE 12/23/2002 o a© o o a a OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPL PERSON (EXF) REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS FER AIR 152 202 152 202 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:12 of 25 1 ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE The Hideaway Gate House 12/23/2002 DESCRIPTION ,Designer 'Enforcement § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. F§ 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. XJ §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). X❑ § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. U §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. r I I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 25 �AILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 PROJECT NAME ---tDATE The Hideaway Gate House 12/23/2002 ILORED 1. Watts for Illuminance Categories A -D (from column G) > p watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) > Q watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) 01+ 1 01+ 1 0 = 1 01 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) > 0 watts ruwr«u cru - muminance t�aie ories A is c ana u ana cross sales Area o a © a o a a ROOM NAME Gate House TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) A 0.00 0 0.20 0 BUILDING PAGE TOTAL TOTAL I 0 011011 QO - >1 SF WATTS EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:14 of 25 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -5 Room Name Task/Activity Description Room Length (L) RoomRoom Width (W) Cavity Height (H) Room Cay. Ratio 5xHx(L+W) /(LxW) Room Name Task/Activity Description Room Area (A) Room Perimeter (P) Room Cavity Height (H) Room Cay. Ratio 2.5 x H x P /A LIGHTING MANDATORY MEASURES LTG -MM NAME The Hideawav Gate House DATE 12/23/2002 j DESCRIPTION Designer 'Enforcement l� 131(d)1 For every floor, all interioi lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. FV I IAI § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X] § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. u §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. o§ 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow.for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. 0 §131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. 17 § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Wafts served from the.electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 25 1 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE The Hideaway Gate House 12/23/2002 --1 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 0 §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. 0 § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X❑ § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the, device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. 0 § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other Isolation areas; and shall be controlled by a time control device as described above. X❑ § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling Is shut off or reduced to a minimum. U § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance ' supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 17 of 25 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE The Hideaway Gate House 12/23/2002 Description IDesigner lEnforcementli Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at + the ventilation rates as specified on these plans. I § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. i JX]u § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. FX]§ 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or E § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or LJ § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or FX] § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). I I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 18 of 25 J • 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME The Hideaway Gate House DATE -7 12/23/2002 'SYSTEM NAME i HVAC -1 FLOOR AREA 1,011 ENGINEERING CHECKS SYSTEM LOAD Number of Systems j 1 COIL COOLING PEAK COIL CFM ISensiblel Latent 1FCFM - Total Room Loads 2,117 36,580 4,233 1,938 Return Vented Lighting 0 Return Air Ducts 1,829 Return Fan 0 Ventilation 202 7,726 3,129 202 Supply Fan 0 Supply Air Ducts 1,8291 TOTAL SYSTEM LOAD I 47,964 7,363 HTG. PEAK (Heating System I Sensible LENNOX HP26-048/CB30M-65 i Output per System 45,600 22,329 Total Output (Btuh) 45,600 i Output (Btuhlsgft) 45.1 1,116 Cooling System 0 Output per System 49,200 9,327 Total Output (Btuh) 49,200 0 Total Output (Tons) 4.1 1,116 Total Output (Btuh/sgft) 48.7 33,888 Total Output (sgft/Ton) 246.6 0.20 Jan 12 am Hir system HVAC EQUIPMENT SELECTION CFM per System 1,600 LENNOX HP26-048/CB30M-65 39,029 5,033 29,990 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.58 Airflow (cfm/Ton) 390.2 Outside Air (%) 12.6 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 39,029 5,033 Jul 4 pm 29,990 Outside Air (cfmisqft) 0.20 Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 63.9 of 81.5 of 81.5 of Supply Air Ducts Outside Air " • O 202 cfm 80.8 of Heating Coil Supply Fan 1600 cfm ROOMS 69.3 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 79.6 / 65.2 of 56.7 / 55.6 of 56.7 / 55.6 of .01 0: Supply Air Ducts Outside Air 202 cfm Cooling Coil Supply Fan o 57.8 / 56.0 F 1600 cfm ROOMS 53.8% R.H. 75.1/63.1 of 74.0 / 62.7 of Return Air Ducts I L— EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 25 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:20 of 25 PROJECT NAME The Hideaway Gate House DATE 12/23/2002 SYSTEM NAME HVAC -1 FLOOR AREA 1,011 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Gate House Gate House 1 2,117 36,580 4,233 2,117 36,580 4,233 1,938 22,329 PAGE TOTAL 1 2,117 36,580 4,233 TOTAL 1 2,117 36,580 4,233 1,938 227329 1,938 22,329 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:20 of 25 ROOM HEATING PEAK LOADS Project Title Date The Hideaway Gate House 112/23/2002 oom Information Design Conditions Room Name Gate House Time of Peak .tan 12 am Floor Area 1,011 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction 4raa I LVahia A -r Or Ct+„IH. R-38 Roof R.38.2xl4.16 surface Area 542.0 x x x x x x x x X X x X X x x X X X X X x X X x x X X X x X x X X x X x X x X 9.70 x 0.0280 x x x x x x x X X X x X X x x X X X X X x X X x x X X X X X X X X X X x X x X x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = 668 4,4731 818 R-21 Wall W.21.2x6.16 1,717.0 0.0592 44.01 01id_a0_0_cL 48.0 0.3872 44.0 Double Metal Clear Default 96.0 0.8500 44.0 3,590 D uble-MetaLCleaLlDefaul 83.0 0.8700 44.0 3,177 Double Metal Clear Default 42.0 0.7200 44.0 1,331 Slab -0 -Grade erimeter = 98.0 44.5 4,361 R-30 Floor F.30.2x10.16 56.0 0.0340 44.0 841 � I I Items shown with an asterisk ('r) denote conduction through an interior Infiltration: 1.00 x 1.064 x —Schedule Air Sensible Fraction to another room. 1 011 x Ceiling Height 0.50 160] ACH Page Total: 44 ILT 18 502 3,827 TOTAL HOURLY HEAT LOSS FOR ROOM 79 z�4 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 21 of 25 I ROOM COOLING PEAK LOADS Project Title I Date The Hideaway Gate House 12/23/2002 OOM INFORMATION DESIGN CONDITIONS Room Name Gate House Time of Peak Jul 4 pm Floor Area 1,011 Outdoor Dry Bulb Temperature 111 C� Indoor Dry Bulb Temperature 74`l= Outdoor Wet Bulb Temperature 78 9F Conduction -38 Roof (R.38.2x14.16) R-21 Wall W.21.2x6.16 Solid Wood Door Double Metal Clear Default Double Metal Clear Default Double Metal Clear Default R-21 Wall W.21.2x6.16 R-21 Wall W.21.2x6.16 ouble Metal Clear Default Area 542.0 548.0 48.0 96.0 38.0 12.0 291.0 611.0 45.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value X 0.0280 X 0.0592 X 0.3872 X 0.8500 X 0.8700 X 0.7200 X 0.0592 x 0.0592 X 0.8700 X X X X X X x x X DETD 1 I 59.6 = = = = = = = = = 37.0 37.3 26.0 26.0 26.9 39.1 38.0 26.0 Page Total Orientation Area x x x X x x X x x x SGF X x x x X x x X X x SC Weighting X x x x x x x X X x Factor = = = = = = = = = = (North) 24.0 36 0.779 0.905 (North) 24.0 36 0.779 0.899 (North) 24.0 36 0.779 0.933 (North) 6.0 36 0.779 0.933 _(North) 6.0 36 0.813 0.933 (East) 6.0 35 0.813 2.086 _(East) 16.0 35 0.779 2.086 (South) 24.0 35 0.779 0.935 (South) 22.5 35 0.779 0.935 South 22.5 35 0.779 0.935 Page Total Btu/hr 905 1 201 693 2.1211 859 232 673 1 374 1 017 9 075 Btu/hr 610 605 628 157 164 356 910 612 574 574 5 189 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor Eaight 1.0 x 1,011 x 1.414 Watts/sgft x 3.41 BtuhIVllatt x 0.999 = 4,875 nts 1.0c x 1,011 X 250 Btuh/occ. / 7 sgt't/OCc. x 1.00 = 3,370 eceptacle 1.0 x 1,011 x 1.500 Watts/sgft x 3.413 Btuh/Watt x 1.00 = 5,176 Process 1.0 x 1,011 x 0.000 Watts/sqft x 3.41 BtuhlWatt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 1 011 x 9.70 x 0.50 /6 ] x 38 = 3 305 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,580 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occu ants1.00 x 1.011 X 200 Btuhlocc. I 75 sgft/occ. = 2 696 Rece tacle QQ x X1 Watts/sqft x BtuhlWatt = 0 Process l 1.00 x 1,011 x 0.000 Waftslsgft x 3.413 BtuhfWatt = 0 Infiltration: �� xx 1 o x 9.70 x E:]7 / 60] x O�Qp3gg� = 1,53 Schedule Air Latent Area Ceiling Height ACH &W EnergyPro 3.1 By EnergySoft User Number: 3665 Page 22 of 25 ROOM COOLING PEAK LOADS Project Title The Hideaway Gate House Date 12/23/2002 Room Name Gate House Time of Peak Jul 4 pm Floor Area 1,011 Outdoor Dry Bulb Temperature 111 O Indoor Dry Bulb Temperature 740F Outdoor Wet Bulb Temperature 78 cl� Conduction R-21 Wall (W.21.2x6.16) Double Metal Clear Default R-30 Floor(F.30.2x10.16) Area 267.01 X 30.0 X 56.0 X X X X X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.05921 DETD 1 X 58.5 = X 26.9 = X 32.0 = X = X = X = X = X = X = Page Total Orientation Area x x x x x x x x x x SGF x x x x x x x x x x Sc Weighting x x x X x x x x x x Factor = = = c c = = (West) 30.0 262 0.813 0.417 _(West) 16.0 262 0.779 0.417 Page Total Btu/hr 925 581 61 1 567 Btu/hr 2,662 1,361 4 023 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor fights 1.0c x 1,0111 x 1.414 Waftslsgft x 3.413 BtuhlWatt x 0.999 = 4,875 Dccu ants 1.00 x 1,011 x 250 Btuh/occ. / 7 sqft/occ. x 1.00 = 3,370 Receptacle 1.0 x 1,011 x 1.500 Watts/sgft x 3.413 Btuh/Watt x 1.00 = 5,176 Process 1.0 x 1,011 x 0.000 Wattslsgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: 1 1.00 x 1.064 x 1 011 x 9.70 x 0.50 /601 x 38 = 3 305 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,580 Sched. Btu/hr Latent Gain Frac. Area Heat Gain OCCUpants 1.00 1 x 1.0111 x 2ool Btuh/occ. / 75 sqft/occ. = 2 696 'Receptacle 1.00 x 0 x 0 09.0Watts/sqft x Btuh/Watt = 0 Process 1.00 x 1,011 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 00 Infiltration:[Schedule 1 00 x x 1.0 x � x / 60] x 1039 = E—t a3 ] Air Latent Area Ceiling Height ACH pyy EnergyPro 3.1 By EnergySoft User Number: 3665 Page: 23 of 25 ROOM COOLING COIL LOADS Project Title The HideawE OOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double Metal Clear Default Gate House Date 12/23/2002 DESIGN CONDITIONS Gate House 1,011 74ck Time of Peak Outdoor Dry Bulb Temperature Outdoor Wet Bulb Temperature Area X X X X X X X X X U -Value X X X X X X X X X DETD 1 = = = = = = = = = 542.0 0.0280 59.6 548.0 0.0592 37.0 48.0 0.3872 37.3 96.0 0.8500 26.0 38.0 0.8700 26.0 12.0 0.7200 26.9 291.0 0.0592 39.1 611.0 0.0592 38.0 45.0 0.8700 26.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Page Total Orientation Area X X x X x x X X X x SGF x x x x x x x X X x SC Weighting X X X x x x x X X x Factor = = = = = = = = = = (North) 24.0 36 0.779 0.905 (North) 24.0 36 0.779 0.899 (North) 24.0 36 0.779 0.933 (North) 6.0 36 0.779 0.933 (North) 6.0 36 0.813 0.933 (East) 6.0 35 0.813 2.086 (East) 16.0 35 0.779 2.086 (South) 24.0 35 0.779 0.935 (South) 22.5 35 0.779 0.935 South 22.5 35 0.779 0.935 Page Total Jul 4 pm MOF 78 Btu/hr 9051 1 2011 6931 _ZA21 859 232 673 1,374 1,017 9 075 Btu/hr 610 605 628 157 164 356 910 612 574 574 5 189 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor �i,huts 1.0 x 1,011 x 1.414 Watts/sqft x 3.41 BtuhlWatt x 0.999 4,875 ccants 11.0c x 1,011 x 250 Btuh/occ. I 7 sgft/occ. x 1.00 = 3,370 Receptacle 1.0 x 1,011 x 1.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 5,176 process 1.0c x 1,011 x 0.000 Wafts/sgft x 3.41 BtuhlWatt x 1.00 = 0 Infiltration: 1.00 x 1.064 x 1 011 x 9.70 x 0.50 /601 x 38 = 3 305 � chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,580 Sched. Btu/hr Latent Gain Frac. Area Heat Gain O, ccuDants 1.00 x 1 1,0111 x 2001 Btuh/OCC. I 75 sgft/occ. = 2 696 Rece tacle 1.00 x 1,011 x MO Watts/sgft x BtuhlWatt = 0 Process 1.00 x 1,011 x 0.000 Wattslsgft x 3.413 Btuh/Watt = 0 Infiltration: O0J x 4 7 x =11i1 x� x Opp / 60] x 0 00394 = 5�3Z chedule Air Latent Area Ceiling Height ACH pyy EnergyPro 3.1 By EnergySoft User Number: 3665 Page: 24 of 25 ROOM COOLING COIL LOADS Title The Hideawav Gate House Zoom Name -loor Area ndoor Dry Bulb Temperature Conduction R-21 Wall (W.21.2x6.16) Date 12/23/2002 DESIGN CONDITIONS Gate House Time of Peak Jul 4 pm I 1,011 Outdoor Dry Bulb Temperature 111 9 74c� Outdoor Wet Bulb Temperature 78 9 Area 267 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.05921 DETD 1 X 58.5 X 26.9 X 32.0 X X X X X X Page Total Orientation Area x X x x x x x x x x SGF x x x X x x x x x x SC Weighting X x x x x x x x x x Factor = = = = = = = = = = (West) 30.0 262 0.813 0.417 (West) 16.0 262 0.779 0.417 Page Total Btu/hr 925 5811 611 1 567 Btu/hr 2,662 1.361 4 023 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor Lights 1.0c x 1,011 X 1.414 Watts/sqft x 3.41 BtuhNVatt x 0.999 = 4,875 Occu ants 1.0 x 1,011 x 250 Btuh/occ. / 75 sgft/occ. X 1.00 = 3,370 eceptacle 1.0 x 1,011 X 1.500 Watts/sqft x 3.41 Btuh/Waft x 1.00 = 5,176 Process (1.0 x 1,011 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: I 1.00 x 1.064 x 1 011 x 9.70 x 0.50 /601 x 38 = 3 305 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,580 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 011 x 2001 Btuhlocc. I 75 sgft/OCc. = 2 696 iRece tacle 104 x x0� Watts/sqft x BtuhlWatt = Process 1.00 x 1,011 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [� x 4 771 x I 1 0,111 x x 160] x 0 00394 = �t�53� Schedule Air Latent Area Ceiling Height ACH pyy I EnergyPro 3.1 By EnergySoft User Number: 3665 Page:25 of 25