Loading...
11-0057 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 11-00000057 Property Address: 77893 GREY WOLF TR APN: 623-510-014- - - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 140000 Applicant: T-ity 4 4 Q" Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: El Li nse No.: 888454 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/03/11 Owner: BUTZLAFF TROY/GRANDYS ANNA 77893 GREY WOLF TRAIL4_ LA QUINTA, CA 92253 ,. Contractor: ) YOUNGS CONSTRUCTION 41501 BROWNSTOWN DRIVE # L { g.! or, ii'!`i` BERMUDA DUNES, CA 92203 )' (760) 238-2383" Lic. No.: 888454 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should becQwe subject to the workers' compensation provisions of Section p� 700 of the Labor Cod all orthwith comply with those provisions. ate: 7 / Applicant: '�✓ i+ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county ttooenter upon the above-mentioned property for inspection pur s. Date: sj jr — Signature (Applicant or Agent): 'r8 Application Number . . . . . 11-00000057 ------ Structure Information STRUCTURAL FIRE REPAIR/ARCHITECTURAL REM ----- Other struct info . . . . . CODE EDITION 2010 ---------------------------------------------------------------------------- $# BEDROOMS 1.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 779.50 Plan Check Fee 506.68 Issue Date . . . . Valuation . . . . 140000 Expiration Date . . 8/02/11 Qty Unit Charge Per Extension BASE FEE 639.50 40.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 140.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 23.51 Plan Check Fee 5.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/02/11 Qty Unit Charge Per Extension BASE FEE 15.00 243.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 8.51 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 37.00 Plan Check Fee 9.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/02/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH AH <=10K CFM 6.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 43.50 Plan Check Fee 10.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/02/11 Qty Unit Charge Per Extension LQPERMIT Application Number . . . . . 11-00000057 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments STRUCTURAL FIRE REPAIR/ARCHITECTURAL REMODEL TO CASITA AND FRONT HALF OF GARAGE. THIS PERMIT DOES NOT INCLUDE ADDITIONAL SQUARE FOOTAGE. 2010 CALIFORNIA BUILDING CODES. February 3, 2011 2:09:06 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 6.00 ENERGY REVIEW FEE 50.67 Fee summary Charged Permit Fee Total 883.51 Plan Check Total 532.69 Other Fee Total 56.67 Grand Total 1472.87 LQPERMIT Paid Credited Due .00 .00 883.51 .00 .00 532.69 .00 .00 56.67 .00 .00 1472.87 #�slit Fla all IA' BUILDING ENERGY ANALYSIS REPORT PROJECT: Butzlaff Residence 77-893 Grey Wolf Trail La Quinta, CA 92253 Project Designer: Perez Collaborative Drafting & Consulting 82-204 Hwy 111, Suite C Indio, CA 92201 (760) 619-8752 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 11.0051 CITY OP -CA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE ti 3 Imi syjz=/ Job Number: Date: 2/3/2011 B -L I FEB 0 3 I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-02-03T11:36:50 /D: TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 1 2 3 8 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Butzlaff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 2/3/2011 Project Address 77-893 Grey Wolf Trail La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 243 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 242 Existing Wall Wood Framed R-13 377 Existing Slab Unheated Slab -on -Grade None 243 Perim = 42' Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 0.8 0.300 0.30 none none None New Front (SE) 38.6 0.400 0.35 none none Bug Screen New Rear (NM 40.0 0.400 0.35 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.00 HSPF Split Heat Pump 15.0 SEER Setback Altered HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Altered HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Instant Elec 0 0.99 All Pipes Ins New FnamvPm 5 1 by EnerovSoft User Number 6712 RunCode: 2011-02-03T11:36:50 ID: Page 3 of 10 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Butzlaff Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 213/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System 25HBB424/FE4AN8003 includes credit for a 11.7 EER Condenser. A certified HERS rater must held verify the installation of the correct Condenser. The HVAC System Altered HVAC incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Altered HVAC incorporates HERS verified Duct Leakage. HERS held verification and diagnostic testing is required to verify that duct leakage meets the specked criteria. EnergyPro 5.1 by EnemySoft User Number. 6712 RunCode: 2011-02-03T11:36:50 /D: Page 4 of 10 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Butzlaff Residence 1 ❑ Multi Family m Existing+ Addition/Alteration 2/3/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.90 5.40 0.49 Space Cooling 152.50 133.83 18.67 Fans 32.46 38.97 -6.51 Domestic Hot Water 85.84 92.11 -6.27 Pumps 0.00 0.00 0.00 Totals 276.70 270.31 6.39 Percent Better Than Standard: 2.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 136 39 Fuel Available at Site: Natural Gas (SM 120 0 Raised Floor Area: 0 (N►M 120 40 Slab on Grade Area: 243 (NE) 80 0 Average Ceiling Height: 8.0 Roof 243 1 Fenestration Average U-Factor: 0.40 TOTAL: 79 Average SHGC: 0.35 Fenestration/CFA Ratio: 32.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 2!3/2011 Address 77-085 Michigan Drive Name Jon Scott Cit State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Perez Collaborative Drafting & Consulting Address 82-204 Hwy 111, Suite C Name Juan Perez City/State/Zip Indio, CA 92201 Phone (760) 619-8752 Signed License # Date EnemvPro 5.1 by EnemySoft User Number., 6712 RunCode: 2011-02-03711:36:50 ID: Page 5 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Butzlaff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 213/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 242 0.026 R-38 0 22 Existing 4.2.1-A9 Altered Residence Wall 80 0.102 R-13 45 90 Existin 4.3.1-A3 Altered Residence Wall 97 0.102 R-13 135 90 Existing 4.3.1-A3 Altered Residence Wall 1201 0.102 R-13 225 90 Existing 4.3.1-A3 Altered Residence Wall 801 0.102 R-13 315 90 Existing 4.3.1-A3 Altered Residence Slab 243 0.730 None 0 180 Existing 4.4.7-A1 Altered Residence FENESTRATION SURFACE DETAILS ID Type I Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Skylight 0.8 0.300 NFRC 0.30 1 NFRC 0 New Solar Tube Altered Residence 2 Window 7.5 0.550 Default 0.55 Default 135 Removed Dual Non Metal Tinted Altered Residence 3 Window 7.5 0.550 Default 0.55 Default 135 Removed Dual Non Metal Tinted Altered Residence 4 Window 7.5 0.550 Default 0.55 Default 135 Removed Dual Non Metal Tinted Altered Residence 5 Window 19.3 0.400 NFRC 0.35 NFRC 135 New Double Non -Metal Tinted Altered Residence 6 Window 19.3 0.400 NFRC 0.35 NFRC 135 New Double Non -Metal Tinted Altered Residence 7 Window 40.0 0.550 Default 0.55 1 Default 315 Removed Dual Non Metal Tinted Altered Residence 8 Window 40.0 0.400 NFRC 0.35 NFRC 315 New Double Non -Metal Tinted Altered Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt REM Dist Len H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 Energypro, 5.1 by EnergySoft User Number. 6712 RunCode: 2011-02-03711:36:50 ID: Page 6 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Butzlaff Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date y3/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Altered HVAC Altered Residence 243 1,944 1985 Totals 0 243 01 0 HVAC SYSTEMS System Name Ot . I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Altered HVAC 1 Split Heat Pump 8.00 HSPF Split Heat Pump 15.0 SEER Setback Altered pre -altered for above Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Altered HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New pre -altered for above Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ WATER HEATING SYSTEMS S stem Name of . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Eemax EX023240TC 1 Instant Elec All Pipes Ins 8,1911 0 0.99 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E w L Hot Water Piping Length ft o i U) Q .9 System Name Pipe Length Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried ❑ 01 1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2011-02-03711:36:50 ID: Page 7 of 10 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Butzlaff Residence Date 2/3/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fire laces Decorative Gas Appliances and Gas Log Measures: 150 e 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150Q)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 (j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2011-02-03T11:36:50 /D: Page 8 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date 9utz1aff Residence 2/3/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause de radation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-02-03T11:36:50 /D: Page 9 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date 3utz1aff Residence 2/3/2011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-02-03711:36:50 /D: Page 10 of 10