Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1251 (SOL)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00001251 Property Address: 49407 GUIJARRO PL APN: 646-270-032- - Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 36000 Applicant: �i'�,NKivl1- T4tyl aF 4 Q" Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: �C�.4�6 License No.: 940550 el %C Date: Contractor: Contractor: k4or RJR -PL G BJE -6Y\.X �� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•: (_ 1 I, as owner of the property, or my employees with wages as their sale compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: BOB SCHOWE 49407 GUIJARRO DR LA QUINTA, CA 92253 ( Contractor: HOT PURPLE INC 870 E. RESEARCH DRIVE, #6 PALM SPRINGS, CA 92262 (760)322-4432 Lic. No.: 940550 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/28/13 e OCT Y�13 CIrvr r L4 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided R for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE COMP. Policy Number 9053981-13 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section - ` 3700 of the Labor Code, I shall forthwith comply with those provisions. Dater Applicant: HOT 19 ��LF2(_Y��� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (9100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quints, its officers, agents and employees for any as or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for i pection purposes. Date: J�ignature (Applicant or Agent): Application Number Permit . . . Additional desc . Permit Fee Issue Date . . . Expiration Date . . . . . . 13-00001251 ELECTRICAL 2013 23.83 Plan Check Fee . . .00 Valuation . . . . 0 4/26/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 23.83 -------------------------------------------------------------_-------_------ Special Notes and Comments 11.7kW SOLAR ARRAY - (36) 327W SUNPOWER PANELS W/(1) 3800W AND (1) 7500W SUNPOWER INVERTER [612SF] 2010 CALIFORNIA ELECTRICAL CODE. October 28, 2013 9:07:40 AM AORTEGA ~ -- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 PLAN CHECK, ELECTRICAL 23.83 PERMIT ISSUANCE M/P/E 90.57 Fee summary Charged Paid Credited Due Permit Fee Total 23.83 .00 .00 23.83 Plan Check Total .00 .00 .00 .00 Other Fee Total 116.40 .00 .00 116.40 Grand Total 140.23 .00 .00 140.23 LQPERMIT T4.ht 4 ,('W ucuGifa COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) DATE: OCTOBER 14, 2013 STATUS: FIRST REVIEW PLAN CHECKED BY: AJ ORTEGA TELEPHONE NUMBER: ( ADDRESS: 49-407 GUIJARRO PL DESCRIPTION: PV SOLAR SYSTEM APPLICANT: SCHOWE/HP ENERGY PLAN CHECK #: 13-1251 This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1- SOLAR (REDLINED) PLAN 2- UNMARKED PLAN SET 1- CORRECTION LIST RTrWVVwrlvt BUILDING DEPARTMENT STAFF: , DO NOT accept any resubmittal unless ALL of the following items are included: 1- SOLAR (REDLINED) PLAN I- CORRECTION LIST w/responses 2- REVISED PLAN SETS 1- ASSESSORS SITE/FLOOR PLAN INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 1 of 2 SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code'5536. Resubmittals will not be accepted with signatures missing. SECTION B — SOLAR jI. Ge 'Reconcile I Wk,�3A at�i concile noted information shown on single line diagram.'See 1s` review redlined plan. Please provide a response for each item, either on returned redlined plan or in letter. VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts 1) The output of a utility -interactive inverter shall be permitted to be connected to the load side of the service disconnecting means of the other source at any distribution equipment on premises. Where such a connection is made, the interconnection provisions of CEC Section 690.64(B)(1) through (B)(7) shall apply. Xhe load calculation provided on plan is incorrect; the actual dwelling square footage on file is 2,587SF, and the calculation already exceeds the proposed 175A derating. Please provide load calculation for the entire dwelling complying with the provisions of Article 220, or revise scope of work (and plan) to show electrical service upgrade. The proposed load center used to combine inverter outputs is required to comply with the Bus or Conductor Rating requirementt f�0.63(B)(2). SECTION C - STRUCTURAL 1) No Corrections Apply. �' �►� SECTION D - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, in items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List (SOLAR) Page 2 of 2 The Management Trust MONARCH GROUP DIVISION September 26, 2013 BOB & KATHY SCHOWE 49-407 GUIJARRO LA QUINTA, CA 92253 RE: Architectural Submittal for 49-407 GUIJARRO Account# Dear Homeowner: The Architectural Review Committee for VILLA LA QUINTA HOA***** has reviewed and APPROVED your architectural submittal for the installation of solar panels per the plans submitted. ARC approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations or restrictions. The ARC shall not be responsible for reviewing, nor shall its approval of any plans or design, be deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving such plans and specifications, neither the ARC, the Members thereof, the Association, any Member thereof, their Board of Directors, any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in the construction or improvement from such plans or specifications. As provided in the CC&R's neither the ARC, the Association, the Board of Directors or the Association or any Members thereof, not the Declarant or Developer shall be liable to any Member, Owner, Occupant, or other person or entity for any damage, loss or prejudice suffered or claimed on account of (1) the approval or disapproval of any plans, drawings, or specifications, whether or not defective, or (2) the construction or performance of any work whether or not pursuant to the approved plans, drawings, or specifications. Your patience and cooperation with the architectural review process is appreciated. If you have any questions, please contact the association at (760) 776-5100, Extension 314. Sincerely, On behalf of the VILLA LA QUINTA HOA***** Architectural Review Committee Rochelle Saenz The Management Trust - Monarch Group Division pff'heft' "�� r1 2�— Enclosures (1) cc: Board of Directors Unit File 39755 Berkey Drive, Suite A, Palm Desert, CA 92211 CONNECTINGPEOPLETOTHEPROMISE PH: 760.776.5100 FAX: 760.776.5111 www.managementtrust.com A Solar PV Installation for: SCHOWE RESIDENCE 49407 GUIJARRO DR, LA QUINTA, CA 9/z5 * BE INSTALLED IN SUCH A MANNER THAT THEY ARE DISCREET AND DO NOT DETRACT FROM THE HOME'S ARCHITECTURE. * ALL EXPOSED CONDUIT & BOXES SHALL BE PAINTED TO MATCH ADJACENT SURFACES. ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKING SHOULD BE PLACED ON ALL AND ABOVE AND/OR BELOW PENETRATIONS AND ALL DC COMBINER AND JUNCTION BOXES. * ADDITIONAL GROUNDING ELECTRODE IS REQUIRED IF RESISTANCE TO GROUND IS 25 OHMS OR LESS PER CEC 250.56 * ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTED LAB. * NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. * WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ "LINE AND LOAD" a Q ~I Z U SYSTEM SIZE: 10.05 kW MODULES: (36) Module Mfr.: Model No.: SUNPOWER SPR-327NE-WHT-D INVERTERS: ( 1 ) Inverter Mfr.: SUNPOWER Model No.: SPR-7501f-240 ( 1 ) Inverter Mfr.: SUNPOWER Model No.: SPR-3801f-240 VJ LU 0 O U Z 0 _J 5 C0 T-1.0 PV-1.0 PV-2.0 PV-3.0 PV-3.1 PV-3.2 RD-4.0 RD-4.1 PV-5.0 PV-5.1 qpw Up111 CITY OF LA QUINTA BUILDING & SAFETY DEPT. AFF-PROVED FOR CONSTRUCTION IDATE BY—&— I TITL SITE PLAN ROOF PLAN ONE LINE DIAGRAM ARRAY NOTES & CALCS NEC-CEC CODE SHEET ENGINEER'S CALCS ROOF DETAILS MODULE CUT SHEETS INVERTER CUT SHEETS * ALL CONSTRUCTION SHALL COMPLY WITH THE: 2010 CALIFORNIA BUILDING CODE 2010 CALIFORNIA MECHANICAL CODE 2010 CALIFORNIA ELECTRICAL CODE 2010 CALIFORNIA PLUMBING CODE 2010 CALIFORNIA ENERGY CODE TAJA SIMS � f� Systems Designer `��/ 760.322.4433 Lic. No. 940550 E E N 0U U � U � 0, o 2) O M = Q C) o C W W �9 z CL Q- LL C N N ZM 2 O O o E o C N U w � O CV rn � U W LLI CU O U _j ~ o CY ch I-- d- M J Drawn by: TS Checked by: BD Date: 09.12.13 Scale: 1 NTS Job Number: 13101 I Sheet Number Total Sheet Count: 1 of 1 PV ARRAY #1: (24) SUNPOWER SPR-327NE-WHT-D 7.848 KW (DC RATING) 6.908 KW (AC RATING) INSTALL NOTES PV ARRAY #2: (12) SUNPOWER SPR-327NE-WHT-D 3.924 KW (DC RATING) 3.454 KW (AC RATING) 1 i i L-- ----- I ------ �1� ------------- I I I � � � i >'� w 1111 � 1• 11f INVERTER #1: (1) SUNPOWER - SPR-7501f-240 (7500W / 240V) INVERTER #2: (1) SUNPOWER - SPR-3801f-240 (3800W / 240V) 75A LOAD CENTER ----- A" AC DISCONNECT: 60A NON -FUSED 3 ARRAY TO BE MOUNTED ON 15° TILT, NOT TO EXCEED 18" IN OVERALL HEIGHT " ALL B-VENTS AND PLUMBING VENTS SHALL EXTEND AT LEAST 6" ABOVE THE ARRAY(S). B-VENTS SHALL EXTEND AT LEAST 2' FT. ABOVE THE ARRAY(S) AT HIGHEST PART OF ARRAY WITHIN 10' FT - UMC 305 AND NEC 110.26 • ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. - CBC 1503 ARRAY DESIGN ANALYSIS HAS BEEN PERFORMED AND ALL OBSTACLES EAST, WEST & SOUTH ARE A MIN. 1 1/2: 1 IN HEIGHT TO AVOID SHADING EFFECTS. . 7 I ti wYL q� V _ EXISTING METER #: X164-780 PROPOSED BIDIRECTIONAL 'METER # -J MAIN SERVICE: 200A GE SYSTEM SIZE DC: 11.772 kW SYSTEM SIZE AC: 10.362 kW s 00 KVA B PHASE IGH: 7.2 KV ' 0W_ 1-20/240V SITE PLAN SCALE: 1 /16" = V-0" CITY OF LA QUINTA BUILDING & SAFE I Y DEPT ` "^' fin aW �r FOR CONSTRUCT[ DATE _ BY. TAJA S;�, / j Systemss D Designer �f��f 760.322.4433 Lie. No. 940550 E E C+1 [[C9yV a)U O U 67 O L Lo a� �, 8 Co M z Q- n. iy S a) - Z � O O 0 I= Z:� _ Co N f` U 0) M Qy o O W O CD C� CI) CI] � J Drawn by: TS Checked by: BD Date: 09.12.13 Scale: AS NOTED Job Number: 13101 Sheet Number: Pv_ 1 . Q" Total Sheet Count: 2 of 10 8 AWG COPPER GROUND (8) 10 AWG THWN-2 STRANDED COPPER WIRE WIRES WILL RUN THROUGH - ATTIC TO INVERTER LOCATED IN GARAGE. ROOF PLAN SCALE: 1 /8" = V-0" 75A LOAD CENTER AC DISCONNECT: 60A NON -FUSED EXISTING METER #: X1 B4-780 PROPOSED BIDIRECTIONAL METER # - - MAIN SERVICE: 200A GE U C W m� 3 00 r-0 U] IK Drawn by: TS Checked by: BD Date: 09.12.13 Scale: AS NOTED Job Number: 13101 Sheet Number: PV-2.0 Total Sheet Count: 3 of 10 PV ARRAY #1: BRAND & MODEL No.: SPR-327NE-WHT-D PTC = 301.4 WATTS STRINGS: MODULEISTRING: NUMBER OF MODULES: PV ARRAY #2: PV ARRAY #2: BRAND & MODEL No.: SPR-327NE-WHT-D PTC = 301.4 WATTS (4) STRINGS: . (2 ) (6 } MODULE/STRING: (6 ) (24) NUMBER OF MODULES: (12) ( � 1 EXISTING METER#: X1 B4-780 PROPOSED BIDIRECTIONAL METER # U.G. SERVICE: UQ-96 100 KVA B PHASE HIGH: 7.2 KV LOW: 120/240V 8 AWG-BARE GROUND 4"X4"X4" NEMA 3R JUNCT. BOX (8) 10 AWG/USE-2 IN 1" EMT 8 AWG-BARE GROUND 4"X4"X4" NEMA 3R JUNCT. BOX -- ------ �dQ� et,P'D MAIN SERVICE: 200A GE ' 22K Al @ 120/240V AC SINGLE-PHASE, THREE WIRE 175A MAIN BREAKER GROUNDING ELECTRODE:f 4 AWG G.E.C. SYSTEM SUMMARY SYSTEM SIZE DC: 11.772 kW SYSTEM SIZE AC: 10.362 kW CITY OF LA QUINTA BUILDING & SAFETY DEPT. FOR CONSTRUCTION 1 DATE lg SY__S&_ A� W1 tA/lv�014-Cs I I 1rw W,44$ Ve SWL&i YEA A'V * I a, i 5A LOAD CENTER SQUARE-D AC DISCONNECT: 20A 60A NON FUSED DISCONNECT F_ -1 OCPD MODEL NO.: DU222RB SERIES E1 1 I I � 1 1 1 OC D I I I �— (3) 6 AWG THWN-2 IN 1" EMT-_J II L cg— (1) 6 AWG THWN-2 GROUND EQUIP, I INVERTER #2: SUNPOWER SPR-3801F-1 UNI (3800W / 240V) AC j I — (3) 10 AWG THWN-2 0 IN 1" EMT --J �— (1) 8 AWG THWN-2 GROUND EQUIP. (3) 8 AWG THWN-2 IN 1" EMT I I I I I I f I �J DC DC INVERTER#1: SUNPOWER SPR-7501F-1 UNI * (7500W / 240V) (1) 6 AWG THWN-2 GROUND EQUIP. I I I I I I — T:17GROUNDING ELECTRODE CONDUCTOR T — TAJA SIMS Systems Designer 760.322.4433 Lic. No. 940550 E E u U U 0]Uj 7 -am O nv WW t� 1 Q- a- N C) C) UJ� '� O O _ E 4 1_ \@ (� Ty v LL C � L o W v a � � W a � 0 C ma Lry [!] iD [j nNl a)Q 0) Q Z [CS O [ Z � C� 0 u3 0 Drawn by: TS Checked by: BD Date: 09.12.13 Scale: N.T.S. Job Number: j 13101 Sheet Number PV-3.0 Total Sheet Count: 4 of 10 1 PV MODULE RATINGS STC (NEC 690. MODULE MAKE SUNPOWER MODULE MODEL SPR-327NE-WHT-D MAX POWER -POINT CURRENT (IMP) 5.98 A MAX POWER -POINT VOLTAGE (VMP) 54.7 V OPEN -CIRCUIT VOLTAGE (Voc) 64.9 V SHORT-CIRCUIT CURRENT (Isc) 6.46 A MAX SERIES FUSE (OCPD) 20 A MAXIMUM POWER (PMAx) 327 W MAX VOLTAGE (TYP 600V.) 600 V VOC TEMP COEFF (mV/K X❑ or %/"C❑) -176.6 IF COEFF SUPPLIED, CIRCLE UNITS NOTES FOR ARRAY CIRCUIT WIRING 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECT AMBIENT TEMPERATURE 0 °C 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE 50 °C 3.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 °C). FOR LESS THAN 9 CURRENT -CARRYING CONDUCTORS IN ROOF -MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. 4.) 690.64(B)(2)(a): TOTAL SOLAR + GRID LOAD NOT TO EXCEED 120% OF BUSS RATING. SYSTEM NOTE PV BREAKER SHALL BE LOCATED OPPOSITE END OF BUSS FROM UTILITY POWER. (ARRAY #1 & #2 RATINGS) TABLE 310.15 AMPACITY: 10 AWG THWN-2: 40A TEMP. CORRECTION FACTOR:.87 [TABLE 310.15] NEW AMPACITY = 40A x .82 = 32.8A 6.46A (Ise) x 1.56 = 10.08A (NEC 690.8) CONDUCTOR: [ 10.08A (Ise) < 32.8A (10 AWG/THWN-2 ALLOWABLE) ] CONDUIT: (ARY #1) [(8) 10 AWG/THWN-2 (MAX) 1" EMT ALLOWABLE] (ARY #2) [(4) 10 AWG/THWN-2 (MAX) 1" EMT ALLOWABLE] 120% RULE [690.64(13)(2)(a)] A. BUSS RATING: 200 A x 120% = 240 A B. MAIN OCPD 175 A + SOLAR OCPD 60 A = 235 A NOTE: B < A (LOAD SIDE CONNECTION) Li NOTES FOR INVERTER CIRCUITS 1.) TOTAL OF 2 INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES X❑ NO ❑ CONDUIT SIZING SCHEDULE ARRAY #1 (DC No. of Conductor Fill Conductors Derating Factor Conduit Fill SIZE (8) #10 AWG 0.82 23.83% 1" EMT (1) #8 G R. ARRAY #2 (DC ) No. of Conductor Fill Conductors Derating Factor Conduit Fill SIZE (4) #10 0.82 14.04% 1" EMT (1) #8 G R. J OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE® REFERENCES SHOWN AS (NEC 240) SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) SOLAR PV SYSTEM AC POINT OF CONNECTION AC OUTPUT CURRENT 1 53.625 A NOMINAL AC VOLTAGE I 240 V THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) INVERTER #1 RATINGS [ NEC - 690.8 INVERTER MAKE SUNPOWER INVERTER MODEL SPR-6501f-1 UNI - 240V MAX DC VOLT RATING 600V MAX POWER @ 40-C 650OW NOMINAL AC VOLTAGE 240V MAX AC CURRENT 27.1 A MAX OCPD RATING 35A _ _ 27.1 A x 125% = 33.875 = 35A (INVERTER #1 RATING) TABLE 310.15 AMPACITY: 8 AWG THWN-2: 55A NEW AMPACITY = 55A x .82 = 45.1A INVERTER #1 RATINGS [ NEC - 690.8 (B)(1) ] SIGN FOR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE RATED MPP CURRENT 23.92 A RATED MPP VOLTAGE 328.2 V MAX SYSTEM VOLTAGE 436.13 V MAX CIRCUIT CURRENT 32.3 A WARNING: ELECTRICAL SHOCK HAZARD - LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION TEMP. CORRECTION FACTOR:.82 [TABLE 310.16]� 33.875A (Isc) < 45.1A (8 AWG/THWN-2 ALLOWABLE) INVERTER MAKE SUNPOWER INVERTER MODEL I SPR-3801f-1 UNI - 240V MAX DC VOLT RATING 600V MAX POWER @ 40"C 380OW NOMINAL AC VOLTAGE'- 240V MAX AC CURRENT 15.8A MAX OCP11 RATING 20A 15.8 A x 125% = 19.75 = 20A SIGN FOR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE RATED MPP CURRENT 11.96 A RATED MPP VOLTAGE 328.2 V MAX SYSTEM V LT GE MAX CIRCUIT Cl.RROV Y QF5 WARNING: E EqMj�gjC& S HAZARD - LINE AND LO Q ENERGIZED I OPE� rNjd (INVERTER #2 RATINGj i TABLE 310.15 AMPACITY: 10 AWG THWN-2: 40A TEMP. CORRECTION I NEW AMPACITY = 40A x .82 = 32.8A 19.75A (Isc) < 32.8A (10 ELECTRICAL LOAD CALCU .82 [TABLE 310.161 J-2 ALLOWABLEI GENERAL LIGHTINf - 2,587 SO. FT. 4,200 W SMALL -APPLIANCE ITS FIRST 10kw at 100% LAUNDRY CIRCUITS - GAS 15 W REMAINDER at 40% WASHER 1,176 W CALCULATED GENERAL LOAD KITCHEN MICRO 708 W DISHWASHER 324 W GENERAL LOAD DISPOSAL 1,650 W A/C #1 CONDENSER KITCHEN REF 715 W A/C #2 CONDENSER HALL WINE CHILLER 538 W POOL -PUMP #1 GAME ROOM WINE CHILLER 288 W POOL -PUMP #2 WATER HEATER - GAS 1,500 W 8kw FUTURE at 240V OVEN/RANGE-GAS 1,500 W GARAGE REF 715 W -�1,849 W 11,849 W 11;8 W 7,200 W 3,840 W 2,304 W FAU #1 04 W WATTS TO AMPS at 240V 173.27 AMPS FAU #2 1 2,00 CONNECTED LOAD 14,622 W NOTE: EXISTING 200A MAIN SERVICE DISCONNECT DE -RATED TO 175A MAIN SERVICE DISCONNECT TO ALLOW FOR 75A BACK FED PV SYSTEM BREAKERS ReAsions: Da e: ® PLAN CHECK #1 10/17/13 TAJASIMS Systems Designer 760.322.4433 Lic. No. 940550 E E N L) U U N > N F_ CD O o 021 �Qch o C C U W W `m a� m tm z a a Z CL M �_ 0_ C:) O O00 M� ll v c .. >+ a W Q)a� LU a ■ 0 -?I 2 EPT. En N U U i N� U � > - otS .En N C/) 0 CN W p Q p U Z 0 ~o .� CY 0) (n J Q Drawn by: TS Checked by: BD Date: 09.12.13 Scale: N.T.S. Job Number: 13101 Sheet Number: PV-3.1 Total Sheet Count: 5 of 10 Date- 1 If 3y2" 690.17/690.53 - DC DISCONNECT - INV. #1 LLI U ry W U) o_ u7 a m CD 3y2" - i ti 690.17/690.54 - AC DISCONNECT - INV. #1 & #2 r M Is co 3y2" 690.17/690.53 - DC DISCONNECT - INV. #2 690.5(C) - INVERTER M N CITY OF LA QUINTA BUILDING & SAFETY DEPT. /` PPROVE FOR CONSTRUCTION DATE 8Y aL - 690.64(B)(7) - PANELBOARD CV TAJA SIMS f Systems Designer } 760.322.4433 Lic. No. 940550 Cq U CO U a) N �, a Q o ©_ Q M n 2' R' C C U N U M Cn z a Q C LL N 7 3 Cq rrJ U) O O > - O -4 00 v C6 � U C ■ ■ L C LLI W �. ' w on a � q) `= � w w U > co LO cN U � U U U) W Z 0 CD Drawn by: TS � Checked by: Date: 09.12.13 Scale: N.T.S. Job Number: 13101 Sheet Number: PV-3.2 Total Sheet Count: 6 of 10 Subject: `/9NC1 & ASSOCIATES Structural Engineers Static load test results for the following: Maximum Frame Maximum Frame Load EquivalentWlndSpeed MountingSystem Length* (In.) Width* an.) (Ibs/ftz) (mph)** Roofrrac ® 65 40 55 135 TEST SETUP (as shown in attached drawing detail): Three modules, as specified above, were bolted to 136"x1.5°x1.5" Professional Solar Products (PSP) patented Rooffrace support rails using an assembly of 5/16" Stainless Steel (SS) bolts, SS lock washers and proprietary aluminum clamps and inserts. The RoofTrac0 support rail was attached to the PSP RoofTrace structural attachment device with a 3/8" SS nut and SS washer at six attachment points. The setup was attached to 2"x6" wooden rafters using 5/16" x 3-1/2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural attachments spaced 48' on center. TEST PROCEDURE (as shown in attached drawing detail): The test set up was top loaded to 55 Ib/ftz. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 55 lb/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.469", with no permanent deformation. The maximum uplift deflection was recorded at 0.313", with no permanent deformation. This document certifies the Roofrracs mounting system used with modules, as specified above, withstands a 55 Ib/ftz static pressure load, equivalent to a wind speed of approximately 135 mph**. The mounting system performed as expected. Sincerely, James R. Vinci, S.E. This engineering report verifies that V'mci & Associates has provided independent observation for load testing as described in this report The results of this load test reflect actual deflection values and are generally accepted as the industry standard for testing module mounting systems. Vinci & Associates does not field check installations or verify that the mounting system is installed as described in this engineering report. To assist the building inspector In verifying the authenticity of this proprietary mounting system, a permanent adhesion, silver reflective "RoofTracm" label, as shown to the right, is placed on at least one of the main support ralIs or permanently stamped with 'Professlonal Solar Prod. Pat #6,360,491' on the underside of rail. Structural attachment: Lag bolt attachment should be installed using the proper pilot hole for optimum strength. A 5/16" lag bolt requires a 3/16" pilot hole. It Is the responsibility of the installer to Insure a proper attachment Is made to the structural member of the roof. Failure to securely attach to the roof structure may result in damage to equipment, personal injury or property damage. This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being installed on. ICC accredited laboratory tested structural attachments manufactured by Professional Solar Products (IncludingFast.lacks, TileTracO, and FoamJaclN) can be Interchanged with this system. Check with local building department or AHJ for site specific requirements. *Modules measuring within stated specifications and tested to UI.1703, or equivalent, are included in this engineering. **Wind Ioadingvalues relative to defined load values usingwind load exposure (135 mph for 5/12 roof pitch or less;115 mph for greaterthan 5/12 roof pitch) and gust factor coefficlent'exposure C' as defined in the 2009(IBC) /2010 (CBC) *** Module tested: 64.6" x 39A* x J-S" (sh rp) ****Est snow load rating of 30 Ib/ft2 based on 1.6 safety factor Thousand Oaks, CA 91362 Page 1 of 3 48' Module Area = 18 ft2 each &W= 2W,� �ft,g Total module (45lbs ea.) and rail (10 lbs ea.) weight: 155 lbs Number of attachments: 6 ea Weight / attachment point: 26 lbs Area: 54 ft2 Distributed weight: 2.9 Ib/ ft2 5/16" Stainless Steel Hex bolt 5/16" Stainless Steel Lock Washer Aluminum ProSolar Inter -Module Clamp Aluminum ProSolar Rail nut 2-1/2" Aluminum ProSolar RoofTrac® Support Rail 3/8" Stainless Steel Hex Bolt and Flat Washer Aluminum ProSolar patented FastJack® Roof Attachment* 5/16" Stainless Steel Lag Bolt and Flat Washer w/ 3-1/2" Embedment 2,984 lbs /i 55 psf I Top Load Deflection: 0.469" 2,984 lbs / 55 psf tab tested structural attachments manufactured by Professional Solar Products (Including Fastlackm , UeTraco, and FoamJack°) can be interchanged with this system. Professional Solar Products Roof7rai a Patent# 6,360,491 Photovoltaic mounting system Page 2 of 3 Up lift Deflection: RoofTrae6 '---1 Solar Modules Static load test RT 4 Revisions: Date: TAJA SIMS Systems Designer 760.322.4433 Lic. No. 940550 E E a)U U iB N > N 0a)a)M 2)21 ❑ < v — LJ cq v U ,.Zr C r= W UJ1 N d) R3 r7S Q CL L4 C RI N 7 7 oCL O Ulm O r EQ J �_ a0 @ c R � C o �► ._ W UJ O U v IC J N CO > I r] U) CJ (3) D W (0 U W o z L7 Ca � a L) Z Ill 0) Ca Drawn by: TS Checked by: BD Date: 09.12.13 Scale: N.T.S. Job Number: 13101 Sheet Number: RD-4.0 Total Sheet Count: 7 of 10 0.6" INTERMODULE CLAMP SPACING — RACK DIAGRAM SCALE: 3/8" = TO" X.—Cr STANDOFFS, SEE ROOF PENETRATION DETAIL --- ------ EXIST. ROOF W/ EXIST. RAFTERS 5/16" X 4" SS LAG SCREW POSTS W/ 3 Y2 STRUCT. EMBED, TYP. RACK DETAIL SCALE: 1" = 1'0" 2" END CLAD SPACING ao IP to - SOLAR MODULES CONDUIT PER PLAN 11Z'-1" COPPER — PIPE GROUND CLAMP COPPER GROUND PER PLAN CONDUIT PER PLAN COPPER GROUND PER PLAN 114" x 20 COPPER SCREW 1& - 1" COPPER PIPE GROUND CLAMP UL DIRECT BURIAL GROUND CONNECTION (UL 467) SCALE: N.T.S. f BONDING SCALE: N.T.S. PV MODULES, — UNIRAC L-FOOT _ — — — — MOUNTING POST, QUICKMOUNT PV RAIL: UNIRAC PRODUCTS (MFR.) COMP SOLAR MOUNT 1S SHINGLE MOUNTS METAL FLASHING TUCK BELOW UP -SLOPE PAPER STAND OVER PAPER >~ WITH MASTIC RAFTER ROOF PENETRATION DETAIL SCALE: 3" = TO" (1) 5/6" x 4" SS LAG SCREW POSTS W/ 3 Y2' STRUCT. EMBED, TYP. - Revisions: Dafe: TAJA SIMS Systems Designer 760.322.4433 Lic. No. 940550 E E CD C.)U 7 CC4 Q cr7 — U cr1 v 2 ❑i: o C C (D a) z as Z U) $ tl 11 0 0 C7 E co A V L � W � v 0 •■• Q) (D E; U C z N ro a)od t� ` N N (D Qz o M L U � W� � L Z LL ea L) 00 � �� Drawn by: TS Checked by: BD Date: 09.12.13 Scale: N.T.S. Job Number: 13101 Sheet Number: RD-4. 1 Total Sheet Count: 8 of 10 20% EFFICIENCY SunPower E20 panels are the highest efficiency panels on the market today, providing more power in the same amount of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest - efficiency panels with the highest -efficiency inverters, maximizing system output REDUCED INSTALLATION COST More power per panel means fewer panels per install. This saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique MaxeonTMcell technology and advanced module design ensure industry -leading reliability MAXEONTM CELL TECHNOLOGY Paienled all-backcontoci solar cell, providing the industry's highest efficiency and reliability E SERIES THE WORLD'S STANDARD FOR SOLAR' SunPowerTM E20 Solar Panels provide today's highest efficiency and performance. Powered by SunPower MaxeonT" cell technology, the E20 series provides panel conversion efficiencies of up to 20.1 %. The E20's low voltage temperature coefficient, anti -reflective glass and exceptional low -light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% 15% 10% 5% SERIES SERIES SERIES sunpowercorp.com CE FE-1] •L dr' C us MODEL: SPR-327NE-WHT-D ELECTRICAL DATA ' I Mea,wed as Standard 7.1 Caedrwru ISTC]- irradiance of I000W/m'. AM 1 5, and .11 Iempe .25' C Peak Power (+5/-3%) Pmax - 327 W Cell Efficiency 0 22.5 % fIf Panel Efficiency ri 20.1 % Rated Voltage Vmr,p 54.7 V Rated Current Impp 5.98 A Open -Circuit Voltage Voc 64.9 V Short -Circuit Current Isc 6.46 A Maximum System Voltage UL 600 V IEC 1000 V Temperature Coefficients Power (P) - 0.38 %/K Voltage (Voc) -176.6 mV/K Current (Isc) 3.5 mA/K NOCT T 45° C +/- 2- C Series Fuse Rating 20 A Grounding - - _ Positive grounding not required MECHANICAL DATA Solar Cells 96 SunPower MaxeonTM cells Front Glass High -transmission tempered glass with anli-reflective (AR) coating Junction Box IP-65 rated with 3 bypass diodes Dimensions: 32 x 155 x 128 mm Output Cables 1000 mm cables / MC4 compatible connectors Frame Anodized aluminum alloy type 6063 (silver); stacking pins Weight 41.0 Ibs (18.6 kg) IN CURVE 7 1 200 W/ms� 0 0 10 20 30 40 50 60 70 Voltage M Current/voltage characteristics with dependence on irradiance and module temperature. TESTED OPERATING CONDITIONS Temperature - 400 F to +185o F (- 400 C to + 85a C) Max load 113 psF 550 kg/m2 (5400 Pa), Front (e.g. snow) w/specified mounting configurations 50 psf 245 kg/m2 (2400 Pa) Front and back (e.g. wind) Impact Resistance Hail: (25 mm) at 51 mph (23 m/s) WARRANTIES AND CERTIFICATIONS Warranties 25 year linear power warranty 25 year limited product warranty Tested to UL 1703. Class C Fire Rating Certifications IEC 61215 Ed. 2, IEC 61730 (SCII) — DIMENSIONS 17 'ice MM 4%3�9[15101 (IN) IC) -i 31I116] C71 %57i :21 193I1 C7] �f�-' I I 322[ 1269] I•'^._ 4k7?0°[9 C7] •� IL+, l- 8 END /_ " I 1559[61.391 ----•� 4e[1 S ] — — i 915136021 EII 4%3131 ICc I 12 <]] 1530[4]211 — 1535[60<51 (A) - MOUNTING HOLES (S) - GROUNDING HOLES IC) -STACKING PINS 12X 06.6 [.26] 1 OX 042 [.171 0 06.1 X 3.2 [0.24 X .131 Please read safety and installation instructions before using'this product, visit sunpowercorp.com for more details. 1 C 2012 5unPower Corporation. 5UNPOWER, IF, SunPower logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON are Irode-6 or rogislered node-6 sunpowercorp.com or SunPower corporation in the US and other countries as wall All Rights Reserved Specifications included in this dolmheel are subject to change wilhoW notice, Doaenem NODI-65350 Rav D / DR_EN CS 12_e32 TAJA SI, S f Systems Designer 760.322.4433 He. No. 940550 E E 04 U U flu (0V >N l.. 00 0 Q CO2 Yam! L L 0) a) W W ,6 C] N (�] 1 Q Q- LL C �y m :3 C Ri IL a- p lnm 00 E 71 a_ co a Cl-r- o CD on TM N W U W C Lq D' U ° Q W U J 5 (D 0 ❑CD 1�1. a U � J Drawn by: TS Checked by: BD Date: 09.12.13 Scale: N.T.S. Job Number: 13101 Sheet Number: PV-5-0 Total Sheet Count: 9 of 10 Electrical Data 100 SPR-6501f-1 UNI SPR-7501f-1 UNI 95 Nominal � 90 AC power P Ac,n m 6500 W- 7500 W_ Nominal 31.3 A @ 208 V 36,.1 A @ 209 V P5 2 AC output IAc.-tr 27,1 A @ 240 V 31.3 A @ 240 V `w 80 current 23.5 A @ 277 V 27.1 A @ 277 V - -- ^- •-- - • --- 75 Voltage range at 183 - 229 V (-12/+10%) @ 208 V V.c 211 - 264 V (-12/+1036) @ 240 V 70 CEC EFFICIENCY AT 95.5% I �230 Vdc r300 Vdc �480 Vdc nominal AC voltage 244 - 305 V (-12/+10%) 9 277 V-- 0110 10 % 20 % 3046 40 % 500". eo% 70 % Solo 901% 100°; AC frequency/ % of Rated Output Power 60 Hz / 59.3 - 60.5 Hz range l - -- - - -- Mechanical Data Power factor cos p 1 I - - -- --- --- - - - SPR-6501E-1 UNI SPR-7501E-1 UNI I Pea inverter efficiency nmax 96.2°5 - Shipping Dimensions ---- - 7 WxHxD 20.3" x 42.7" z 14.4" 95.03'. @ 208 V 95.0%'' 203 V - - -- -- - - t CEC efficiency nCEC 95.5% @ 240 V 95.5,. @ 240 V Unit Dimensions 17,1 38.1 "x"x9,9" 96.0%@277V 96.0769277V WxHxD I Max. DC input PDC,mcc 7500 W 8600 W Unit Weight 81 Ibs power _.. Shipping weight 90 Ibs MPP voltage range Vi>c rdpp 230 V - 500 V I Number of MPP �Y Topology High frequency transformer trackers- �. ' Max. DC input •" '" - Cooling Controlled forced venlllaYion, variable Fan speed voltage VDc,T,�, 600 V Enclosure NEMA 3R Max. DC input 1 DC,raa 30.4 A 35.1 A -- - - currcnF - _ _ _ _ -. _ -. -. Mounting Vertical wall mounting DC harmonic distortion <3% Ambient temperature range •13'F to +131'F Number of string inputs Warranty Warranty and Conformity to Standards Number of phases T on AC side SPR-6501f-1 UNI SPR-7501f-1 UNI DC disconnect Integrated DC disconnect switch - � - Warranty 10 year limited warranty Pre -configured for positive DC grounding and use with SunPower PV modules Grounding Reconfigurable in The field for negative DC grounding and use with Serengeti PV modules Ground fault Included detection , Nightime power -- - ----------------- --- -<1.5 W consumption - - - - - - - - Conformity to standards UL 1741-2010 IEEE 1547-2003 IEEE 1547.1 ANSI/IEEE C62.41 FCC Part 15 A & B NEC Article 690 C22. 2 No, 107.1-01 (September 200 1) About SunPower SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high -efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles, and trackers deliver significantly more energy than competing systems. SUNPOWER and the SUNPOWER bgo ore bademorks or registered nodemarhs of SunPower Corporation, sunpowercorp.com • ) November 2010 SurPo- Corporation, All rights reserved. Specificoli n incuded in this daloshcai ore subject to thongs withom notice Document 4 00IL4795 P.ev-A / UP. EN - CEC EFFICIENCY AT 95.5% Electrical Data - 100 I SPR-3301f-1 UNI SPR 3801f 1 UNI 95 90 Nominal AC power PAC,roa 3300 W 380O W as Nominal 15.9A@203V 18.3A@208V AC output IAc.� 13.8A@240V 15.8Aa-240V `w 80 -- current 11.9 A @ 277 V �z3o vdc Voltage range nF -1 23() Vdc 183 - 229 V (-12/+10 0( @ 208 V _c 450 We nominal AC voltage VAC 211 - ^.x.4 V ; i 2/+10?^1 @ 240 V I ro I -�- -- 244 - 305 V (-12/+10°SI @ 277 V- - - - 0% 10% 20 30% 40% as.._ .- 80% 905; 100S1. AC frequency/ % of Rated Output Power range 60 Hz / 59.3 - 60,5 Hz Power factor aa, p 1 J Mechanical Data - - - SPR-3301f-1 UNI SPR-3801f-1 UNI Peak inverter " efficiency 06 21 nm°% Shipping Dimensions 20.3" x 31.1" x 14.4" 95.5%@ zoo v 95.o�a @ zoo v WxHxD _ .. CEC efficiency 9CEC 95.5% @ 240 V 95.5% @ 240 V Unit Dimensions 7 1 ^ x 26.5" x 9.9" -- 96,095 @ 277 V 96.0% @ 277 V --- - WxHxD Max. DC input PDC. = 3800 W 4400 W Unit Weight 55 Ibs power - - ------ --- ---� -. -- MPP voltage range VDCMPP---- -----_ 230V=500VShipping weight 5916s � --------- -- Number of MPP Topology High frequency transformer trackers Max. DC input Cooling Controlled For_ed ventilation, variable fan speed voltage V---. 600 V _ _ -• _ - • _ - • _ Max. DC input I Enclosure NEMA 3R a•m=• 15.4 A 17.8 A current --- Mounting Vertical wall mounting DC harmonic <3% distortan Ambient temperature range 13`F to +131 `F Num6ar of string - inputs 6 Warranty and Conformity to Standards Number of phases on AC side 1 SPR-330lf-1 UNI SPR-3801f-1 UNI DC disconnect Integrated DC disconnect switch - -- ,----_------- -_--- - - -- -- Warranty 10 yew limited warrant' Pre -configured for positive DC grounding and use with SunPower PV modules Grounding UL 1741-2010 Reconfigurable in the field for negative IEEE 1547-2003 DC grounding and use with Serengeti PV modules IEEE 1547.1 _ Conformity to standards ANSI/IEEE C62.41 Ground fault FCC Part 15 A & 8 detection Included NEC Article 690 C22. 2 No. 107.1-01 (September 2001) Nightime power consumption `1-5 W About SunPower SunPower designs, manufactures, and delivers high-performance solar electric technology worldwide. Our high -efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles, and trackers deliver significantly more energy than competing systems. SUNPOWER and the SUNPOWER logo are tmdcmarl3 or mgi,lered trademodcs of SmPawer Cwpamliv,. s u n pO W e rco rp. CO m 96 November 2010 Sued ,er Corpomtion All rights reserved Speeificmmns included In thi_ dmashmi are subject to change v.5thaui nonce Dxomenl p 001d4794 Rov'A/ IT EN Revisions: Date: TAJA SIMS Systems Designer 760.322.4433 Lic. No. 940550 N N a) O O a) > N a7 O CD m ❑ Q co '0 a) a) a) U� rn W W ` T ci a) a) M p) I Z LL C N a> Q Q CD 3 CDU) 12 O O E� J _ 00 M O C _ Vl Q) o ICJ 0 73 3C fthill w (1) 0 r rW VJ a) C') > N U rn U W N N Ut L I_ O \> C:) CY U) Z J Drawn by: TS Checked by: BD Date: 09.12.13 Scale: N.T.S. Job Number: 13101 Sheet Number: PV-5. 1 Total Sheet Count: 10 of 10