11-0550 (MECH) Revised CF-1R Forms2011-07-19 09:09 ALL SEASONS 7602023067 >> P 2/3 Simplified Prescriptive Certificate of Compliance: 2008 Residential HVAC Alterations CF-iR-ALT-HVAC Climate Zones 10 - 15 Site Address: Enforcement Agency: Date: Permit #: 50600 Spyglass Hill Drive La Quinta, CA 92253 City of La Quinta Jul 18, 2011 Equipment Typel List Minimum Efficiency2 Duct insulation requirement Conditioned Floor Area Thermostat ❑ Package Unit p Furnace * Indoor Coil AFUE 7 % _ R SEER l ❑ COP ❑ HSPF U R 6 (CZ 10-13) Served by system p Setback not already present, must be * Condensing Unit ❑ EER ❑Resistance ❑ R 8 (CZ 14-15) 1200 sf in installed) ❑ Other 1. T- Equipment Type: Choose the equipment being installed; if more than one system, use another CF-1R-ALHVAC for each system. 2. Minimum Equipment Efficiencies: 13 SEER, 78% AFUE, 7.7HSPF for typical residential systems. HERS VERIFICATION SUMMARY Listed below are FOUR HVAC alteration Options. The installer decides what work is being done and picks one of the appropriate Options. Each Option lists the HERS measures that must be conducted. A copy of the forms shall be left on site for final inspection and a copy given to the homeowner. At final, the inspector verifies that the work listed on this form was in fact the work completed by the installer. The inspector also verifies that each appropriate CF-6R and registered CF-4R forms (no hand filled CF-4Rs allowed) are filled out and signed.Beginning October 1, 2010, a registered copy of the CF-iR and CF-6R shall also be on site for final inspection. 211. HVAC Changeout Required Forms: • All HVAC Equipment CF-6R forms: MECH-04, MECH-2I-HERS and (for split systems) MECH-25-HERS replaced CF-4R forms: MECH-21 and (for split systems) MECH-25 • Condenser Coil and /or • Indoor Coil and /or CF-6R forms: MECH-04, MECH-2I-HERS and (for split systems) MECH-25-HERS • Furnace CF-4R forms: MECH-21 and (for split systems) MECH-25 For Split Systems: Duct leakage < 15 percent; RC, CCA <_ 300 CFM/ton (Minimum Air Flow Requirement), TMAH Exempted from duct leakage testing if: 1. Duct system was documented to have been previously sealed and confirmed through HERS verification, or 2. Duct systems with less than 40 linear feet in unconditioned space, or 3. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. The system will not be Ducted (ie. Ductless Mini -Split System) (Also Exempt from Refrigerant Charge) ❑ 2. New HVAC System Required Forms: Cut in or Changeout with new ducts: (all new CF-6R forms: MECH-04, MECH-20-HERS, "and (for split systems) MECH-22-HERS, and MECH-25-HERS ducting and all new CF-411 forms: MECH 20, and (for split systems) MECH-22, and MECH 25 equipment) For Split Systems: Duct leakage < 6 percent; RC, CCA z 350 CFM/ton, FWD, TMAH, STMS, and either HSPP or'PSPP. For Packaged Units: Duct leakage < 6 percent ❑ 3. New Ducts with/or without Required Forms: Replacement . Includes replacing or installing all new ducting and/or outdoor condensing unit and/or indoor CF-6R forms: MECH-04, MECH-20-HERS, and (for split systems) MECH-25-HERS coil and/or furnace. No or some equipment CF-4R forms: MECH-20 and (for split systems) MECH-25 changed. For Split Systems: Duct leakage < 6 percent; RC, CCA >_ 300 CFM/ton, TMAH For Packaged Units: Duct leakage < 6 percent ❑ 4. New Ducting over 40 feet Required Forms: . Includes adding or replacing more than 40 CF-6R forms: MECH-04, MECH-2I-HERS 1CF-4R linear feet of duct in unconditioned space. forms: MECH-21 For split system or packaged units: Duct leakage < 15 percent ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. Contractor (Documentation Author's /Responsible Designer's Declaration Statement) • I certify that this Certificate of Compliance documentation is accurate and complete. • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. • The design features identified on this Certificate of Compliance are consistent with the information documented on other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with the permit application. Name: David Beale Signature: David Beale Company: ALL SEASONS AIR CONDITIONING PLUMBING & HEATING INC Date: May 26, 2011 Address: P 0 BOX 1112 License: 827420 City/State/Zip: PALM DESERT / CA / 92261 Phone: (760) 568-2663 Reg: 211-A0025385B-00000000-o000 Registration Date/Time: 2011/05/26 10:30:59 HERS Provider: CaICERTS, Inc. 2008 Residential Compliance Forms July 2010 2011-07-19 09:13 ALL SEASONS 7602023067 >> P 3/3 Simplified Prescriptive Certificate of Compliance: 2008 Residential HVAC Alterations CF-iR-ALT-HVAC Climate Zones 10 - 15 Site Address: Enforcement Agency: Date: Permit #: 50600 Spyglass Hill Drive La Quinta, CA 92253 City of La Quinta Jul 18, 2011 Equipment Typel List Minimum Efficience2 Duct insulation requirement Conditioned Floor Area Thermostat ❑ Package Unit W Furnace Indoor Coil © AFUE 7 % [�j SEER 15.0 ❑ COP ❑ HSPF J R 6 (CZ 10-13) Served by system 0 Setback If not already present, must be (� Condensing Unit ❑ EER ❑ Resistance ❑ R 8 (CZ 14-15) 1200 sf installed) ❑ Other 1, Equipment Type: Choose the equipment being installed; if more than one system, use another CF-IR-ALT-HVAC for each system. 2. Minimum Equipment Efficiencies: 13 SEER, 78% AFUE, 7.7H5PF for typical residential systems. HERS VERIFICATION SUMMARY Listed below are FOUR HVAC alteration Options. The installer decides what work is being done and picks one of the appropriate Options. Each Option lists the HERS measures that must be conducted. A copy of the forms shall be left on site for final inspection and a copy given to the homeowner. At final, the inspector verifies that the work listed on this form was in fact the work completed by the installer. The inspector also verifies that each appropriate CF-6R and registered CF-4R forms (no hand filled CF-4Rs allowed) are filled out and signed.Beginning October 1, 2010, a registered copy of the CF-iR and CF-611 shall also be on site for final inspection. 1. HVAC Changeout Required Forms: . All HVAC Equipment CF-6R forms: MECH-04, MECH-2I-HERS and (for split systems) MECH-25-HERS replaced CF-4R forms: MECH-21 and (for split systems) MECH-25 . Condenser Coil and /or . Indoor Coil and /or CF-6R forms: MECH-04, MECH-2I-HERS and (for split systems) MECH-25-HERS . Furnace CF-4R forms: MECH-21 and (for split systems) MECH-25 For Split Systems: Duct leakage < 15 percent; RC, CCA <_ 300 CFM/ton (Minimum Air Flow Requirement), TMAH leakage , 5 peFEef* Exempted from duct leakage testing if: ❑ 1. Duct system was documented to have been previously sealed and confirmed through HERS verification, or ❑ 2. Duct systems with less than 40 linear feet in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. The system will not be Ducted (ie. Ductless Mini -Split System) (Also Exempt from Refrigerant Charge) ❑ 2. New HVAC System Required Forms. . Cut in or Changeout with: new ducts: (all new CF-6R farms: MECH-04, MECH-20-HERS, and (for split systems) MECH-22-HERS, and MECH-25-HERS ducting,and all new CF-4R forms: MECH 20, and (for split systems) MECH-22, and MECH 25 equipment) For Split Systems: Duct leakage < 6 percent; RC, CCA Z 350 CFM/ton, FWD, TMAH, STMS, and either HSPP or PSPP. For Packaged Units: Duct leakage < 6 percent G 3. New Ducts with/or without Required Forms: Replacement . Includes replacing or installing all new ducting and/or outdoor condensing unit and/or indoor CF-6R forms: MECH-04, MECH-20-HERS, and (for split systems) MECH-25-HERS coil and/or furnace. No or some equipment CF-4R forms: MECH-20 and (for split systems) MECH-25 changed. For Split Systems: Duct leakage < 6 percent; RC, CCA >_ 300 CFM/ton, TMAH For Packaged Units: Duct leakage < 6 percent ❑ 4. New Ducting over 40 feet Required Forms: . Includes adding or replacing more than 40 CF-6R forms: MECH-04, MECH-2I-HERS linear feet of duct in unconditioned space. CF-4R forms: MECH-21 For split system or packaged units: Duct leakage < 15 percent ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. Contractor (Documentation Author's /Responsible Designer's Declaration Statement) • I certify that this Certificate of Compliance documentation is accurate and complete. • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts i and 6 of the California Code of Regulations. • The design features identified on this Certificate of Compliance are consistent with the information documented on other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with the permit application. Name: David Beale Signature: David Beale Company: ALL SEASONS AIR CONDITIONING PLUMBING & HEATING INC Date: May 26, 2011 Address: P O BOX 1112 License: 827420 City/State/Zip: PALM DESERT / CA / 92261 Phone: (760) 568-2663 Reg: 211-A0025384B-00000000-0000 Registration Date/Time: 2011/05/26 10:29:54 HERS Provider: Ca10ERTS, Inc. 2008 Residential Compliance Forms July 2010