Loading...
13-0140 (AR) Revision 1L C Bin# �o City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �— / `�O Project Address: 7 Owner's Name: A. P. Number: Address: ( _10 �� W Legal Descript' City, ST, Zip: pb-p, ' (-INOO Contractor: 0 4 Telephone: Z.O Address: Project Description: City, ST, Zip: /FV/3L0A1 f I-, Telephone: `<f::>:<<:::s»>>::;::<::;s<'.':%<':<r<: G State Lic. # : City Lic. Arc , Engr., Designer: 64-L Address: .f City., ST, Zip: Q Telephone: 77� ;;:.:.,:>:;;,::.;:::;:;.::;::«;::.::•::.;;:;;•;:::•: Construction Type: Occupancy: State Lic. Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: (/�j� L6 f Sq. Ft.: # Stories: # Units: Tele hone # of Contact Person: p 7 � . �6 �) ` '- � '.'Estimated Value of Project: � - APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Ak Flood plain plan Plans resubmitted Mechanical Electrical 4� Plumbing Aj Grading plan 2°" Review, read�c�o�rrecoissue Subcontactor List Called Contact Person Grant Deed Plans picked up Z S.M.1. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correcti sfissue .INN Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr School Fees Date of permit issue V we L Total Permit Fe4u)L S�RJc_ oui Kip. P/G to Pt4s0,j Wlb 60 TNG oRb(,%4-` P/C_ alC 3 Rarer . paxw 0P lC Z56 (crr� of �J UYNTA LA COMMUNE ®EVELOPMENT - Re o t S Gip SAY g BUILDING ENERGY ANALYSIS REP RT 6 FF1 (E= 5&f PROJECT: The Miller Residence - Bedroom Addition 77-182 Calle Flora La Quinta, CA 92253 Project Designer: Ochoa Design Associates 73-626 Highway 111 Palm Desert, Ca 92260 760-773=6605 Report Prepared by: Maria Jeccett Chasco BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 Date: ��L 1 2013 7/17/2013 6----rl � Ru BUILDING & The EnergyPro computer program has been used to perform the calculations summarized in this � mp isQce L authorized by the California Energy Commission for use with both the Residential an6 Nonresi�a t A 09 This program developed by EnergySoft, LLC —�M-eZQ264;PN INT UCTION and is PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Miller Residence - Bedroom Addition Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/17/2013 Project Address 77-182 Calle Flora La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 607 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST EI Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Wall Wood Framed R-19 625 New Roof Wood Framed Attic R-38 607 Radiant Barrier New Slab Unheated Slab -on -Grade None 607 Perim = 142' New Wall Wood Framed R-21 0 Int --R-7.0 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (N) 20.0 0.340 0.25 2.0 2.0/0.0 Bug Screen New Rear (S) 47.0 0.340 0.25 2.0 2.0/0.0 Bug Screen New Front (N) 142.4 0.330 0.29 2.0 2.010.0 Bug Screen New Front (N) 48.0 0.340 0.25 2.0 2.0/0.0 Bug Screen New Rear (S) 142.4 0.330 0.29 2.0 2.0/0.0 Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.2 SEER Setback New 1 Central Furnace 80% AFUE No Cooling 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC #2 Ductless/with Fan Ductless n/a n/a New HVAC #1 Ducted Ducted Conditioned 8.0 New WATER HEATING C;. �" OF LA QUO Ot . Type Gallons Min. Eff Distrib,'006ILDING, A R 1 Large Gas 60 0.94 No Pipe Insulation A ,r,) D C.a — r,_New - -o w Y Ili �`�` .. `~ 1 J V 9 EnergyPp 5.1 by EnergySoft User Number 3665 RunCode: 2013-07-17T10:46:41 ID: f 18 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name The Miller Residence - Bedroom Addition Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 717/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verfication to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bosch Electic Tankless AE125 is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC #2 must serve only Sleeping Areas. The non-closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air How requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Lennox SL280UH070V36A-' does not include a cooling system, field verification is not necessary. The HVAC System HVAC #1 must serve only Living Areas. The non-closable area between zones cannot exceed 40 sf and each zone must have a se crate thermostat. In addition the air now requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The Roof R�8 Roof includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Fujitsu 18RLXFW Wall (19.2 SEER) includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC #2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The Cooling System Lennox SL280UH070V36A-' includes credit for a 10.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC #1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC #1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC #1 has the HVAC unit and no more than 12 feet of Ducts and Plenums located outside conditioned space. A certified HERS rater must visually verify the installation of all Ducts and Plenums. Fr. I Tv n M `r1 I BUILDING & SAFETY APPROVE Ul 5 I HUCTION LE,ePro if 5.1 b Ene Soft User Number. 3665 RunCode: 2013-07-17T10:46:41 ,ID: Page 4 18 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name 7ilding Type m Single Family ❑ Addition Alone Date The Miller Residence - Bedroom Addition ❑ Multi Family ❑ Existing+ Addition/Alteration 1711712013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.16 6.05 -0.89 Space Cooling 76.02 90.92 -14.91 Fans 16.02 20.43 -4.41 Domestic Hot Water 37.88 16.68 21.20 Pumps 0.00 0.00 0.00 Totals 135.08 134.08 0.99 Percent Better Than Standard: 0.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 438 210 Fuel Available at Site: Natural Gas (E) 139 0 Raised Floor Area: 0 (S) 448 189 Slab on Grade Area: 607 (►M 0 0 Average Ceiling Height: 10.0 Roof 607 0 Fenestration Average U -Factor: 0.33 TOTAL: 400 Average SHGC: 0.28 Fenestration/CFA Ratio: 65.9 °i REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING ldU'�„� 7/1712013 Address 75-145 St. Charles Place Name Maria Jeocett Chasco City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing re uire installer testing and certification and field verification by an approved HE S ter, OF LA Q U 0 NTA Designer or Owner (per Business & Professions Code) BUILDING 6 -ETY DEPT. Company Ochoa Design Associates, �� p`� 73 626 Highway 111 Eduardo Escobar � ' Address 9 Y Name r� 7 , , . , F. City/State/Zip Palm Desert, Ca 92260 Phone 760-773-6605 Signed License # Date . DATE BY EnemyPrp 5.1 by EnemySoft User Number. 3665 RunCode: 2013-07-17T10:46:41— —0. ge 5 of 18 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name The Miller Residence - Bedroom Addition Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1711712013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 147 0.074 R-19 0 90 New 4.3.1-A5 Zone #2 Wall 157 0.074 R-19 180 90 New 4.3.1-A5 Zone #2 Roof 200 0.025 R-38 0 0 New 4.2.1-A21 Zone #2 Slab 200 0.730 None 0 180 New 4.4.7-A1 Zone #2 Wall 0 0.049 R-21 7.0 Wood 0 90 New 4.3.1-A6 Zone #2 Wall 81 0.074 R-19 0 90 New 4.3.1-A5 Zone #1 Wall 102 0.074 R-19 180 90 New 4.3.1-A5 Zone #1 Wall 139 0.074 R-19 90 90 New 4.3.1-A5 Zone #1 Roof 407 0.025 R-38 0 0 New 4.2.1-A21 Zone #1 Slab 407 0.730 None 0 180 New 4.4.7-A1 Zone #1 FENESTRATION SURFACE DETAILS ID Type Area LI-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 20.0 0.340 NFRC 0.25 NFRC 0 New Je/d-Wen Clad Zone #2 2 Window 10.0 0.340 NFRC 0.25 NFRC 180 New Jeld-Wen Clad Zone #2 3 Window 10.0 0.340 NFRC 0.25 NFRC 180 New Jeld-Wen Clad Zone #2 4 Window 142.4 0.330 NFRC 0.29 NFRC 0 New Jeld-Wen Clad Lo/E (SIdGIsDr) Zone #1 5 Window 48.0 0.340 NFRC 0.25 NFRC 0 New Jeld-Wen Clad Zone #1 6 Window 27.0 0.340 NFRC 0.25 NFRC 180 New Jeld-Wen Clad Zone #1 7 Window 142.4 0.330 NFRC 0.29 NFRC 180 New Jeld-Wen Clad Lo/E SIdGIsDr) Zone #1 (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade T H e SHGC t T Wd Ove hang Left Fin Len H t LExt RExt Dist I Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 0.11 2.0 0 0.0 0.0 0 2 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.0 0.0 0 3 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.0 0.0 0 4 Bug Screen 0.76 8.9 4.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.0 0.0 0 5 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.0 0.0 0 6 Bug Screen 0.76 4.6 6.0 2.0 0.1 2.0 2.0 0.1 2.0 01 0.0 0.0 0 7 Bug Screen 0.76 8.9 4.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.0 0.0 0 A 1 ►I n1h,h " [+ �^ rTirihi EnergyPro 5. 1 by EnergySoft User Number. 3665 RunCode: 2013-07-17710:46:41 -- -1D: Pa 6 of 18 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name The Miller Residence - Bedroom Addition Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina Altered Removed Volume Year Built HVAC #2 Bedroom 200 2,000 HVAC #1 Bar 8 Breezeway 407 4,070 Totals 1 607 0 0 0 HVAC SYSTEMS System Name Oty. Heating T e Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC #2 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.2 SEER Setback New HVAC #1 1 Central Furnace 80% AFUE No Cooling 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC #2 Ductless /with Fan Ductless n/a n/a ❑ New HVAC #1 Ducted Ducted Conditioned 8.0 ❑ New ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bosch Electic Tankless AE 1 Large Gas No Pipe Insulation 125,000 60 0.94 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Oty. HP Hot Water Piping Length ft 0 m �op ¢ — ,ste t;(Na�rt 6:Ler" t i Zte Insul. Thick. Plenum Outside Buried ❑ o r, I r ❑ ❑ dh R M ❑ t' 'QR rnim . T EnergyFro 5.1 by EnergySoft User Number. 3665 RunCode: 2013-07-17T 0.0.41- ---1D: BY a e 7 of 18 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date The Miller Residence - Bedroom Addition 7/17/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is s ecified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor or equivalent Ll -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 4150(q): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 4150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 extemal insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture; a ui mentmainte an a §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardan'tZir i e I I i conditioned space. I R, a i l [ING R.. XE 150(a)4: Solar water-heatingsystems and/or collectors are certified b the Solar Ratin and Certitica V l FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-074MO1 6:41 ID: Pa& 8 of 18 I uA ► t By I MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name The Miller Residence - Bedroom Addition Date 7/17/2013 §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and retum-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lishting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than-2®=watts-ef-pewer-peMi illuminated cabinet. ( !-`ITS/ BUILDING & SAFETY DEPT. APPROVED rOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-07-17710:46:41 i ID: Page 9 18 �t�TE BY I MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date The Miller Residence - Bedroom Addition 7/17/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception'! to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130,132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130,131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION nATF BY EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2013-07-17T10:46.4 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Miller Residence - Bedroom Addition Date 7/17/2013 System Name HVAC #2 Floor Area 200 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 181 3,859 548 121 Return Vented Lighting 0 Return Air Ducts 0 Return Fan 0 Ventilation o 0 0 o Supply Fan 0 Supply Air Ducts 0 TOTAL SYSTEM LOAD 3,859 F 548 PEAK Heating System Sensible Output per system 21,600 4,748 Total Output Btuh 21,600 Output Btuh/ ft 108.0 0 Cooling System 0 Output per System 18,000 0 Total Output Btuh 18,000 0 Total Output ons 1.5 0 Total Output Btuh/s ft 90.0 Total Output s ft/Ton 133.3 4,748 Air S tem CFM per System 541 HVAC EQUIPMENT SELECTION Airflow chn 541 Fujitsu 18RLXFW Wall (19.2 SEER) 14,664 526 13,491 Airflow (cfm/ ft 2.71 13,491 Airflow cfm/Ton) 360.7 Outside Air % 0-0% Total Adjusted System Output 14,664 526 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/ ft 0.00 Note: values above given at ARI conditions I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfrn 68 OF 68 °F 105 OF 105 OF Heating Coil Supply Fan ° 541 Cfrri 105 F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 °F Outside Air 0 cfm 75 / 62 OF 75 / 62 OF 55154 OF 55 ! 54 OF cop c Cooling Coil Supply Fan CITY OF LA QUI o 541 cfm i E l [3l � 47... SAI Wb w T �� CU�iJT.4 4iRYUVT�ON 5 /� 2 ° i DA"M BY Y EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2013-07-17T10:46:�f-'-- 7 a e 1 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Miller Residence - Bedroom Addition Date 7/17/2013 System Name HVAC #1 Floor Area 407 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. CFM Sensible Latent CFM 500 10,271 603 237 0 149 0 0 0 0 0 0 149 1 10,568 603 PEAK Heating System Sensible Output per System 52,000 9,214 Total Output Btuh 52,000 Output Btuh/ 1t 127.8 110 Cooling System 0 Output per System 0 0 Total Output Btuh 0 0 Total Output ons 0.0 110 Total Output Btuh/ 0.0 Total Output s on 0.0 9,434 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow (cfm) 0 Lennox SL280UH070V36A-' 0 0 52,000 Airtlow ctm/s ft 0.00 Airflow cfm/Ton 0.0 Outside Air 0/6 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 1 0 0 1 52,000 Aug 3 PM Jan 1 AM Outside Air cfm/ 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 67 OF 105 OF Heating Coil 104 OF ROOM )" 68 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfinC 76/63°F 76/63°F 55/54°F c Cooling Coil a I °F t B T OFF LA QUI DUILD49Nt %& S AND P APP 5/62°F FOR CONSTRl1C;T nN I DATE EnergyPro 5.1 by EnergySoff User Number. 3665 RunCode: 2013-07-17710:46:411 _.__ Page 12 of 18 ROOM L• SUMMARY Project Miller Residence - Bedroom Addition Date 711712013 System Name HVAC #2 FloorThe 00 ROOM • ZEN PAGE TOTAL • sm�®� ROOM OAD SUMMARY - . Miller Residence - Bedroom Addition Date 711712013 System Name FloorThe ROOM LOAD SUMMARY Totalventilation load for zonal TOTALPAGE TOTAL • m l ROOM HEATING PEAK LOADS Project Name Date The Miller Residence - Bedroom Addition 7/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom Time of Peak Jan 1 AM Floor Area 200.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 68 OF Conduction Area U -Value AT'F Btu/hr R-19 Wall 304.0 X 0.0740 X 42 = 945 Jeld-Wen Clad 40.0 X 0.3400 X 42 = 571 R-38 Roof 200.0 X 0.0250 X 42 = 210 Slab -On -Grade perm = 86.0 X 0.7300 X 42 = 2,637 X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X Items shown with an asterisk (') denote conduction through an interior surface to another room Total 4,363 Infiltration:[ 1.00 X 1.064 X 200 X 10.00 > (b?259 !Page (/Sp F A,�I�J t�' �91 385 Schedule Air Sensible Area Fraction Ceiling Height A E3&LDING �. & SAFETY DEPT. APPBOVED TOTAL HOURLY HEAT LOSS FOR ROOM ! r", , r- L4,48 Ene Pro 5.1 b Ene Soft User Number.• 3665 RunCode: 2013-07-17710:46:41 -,-JD: a e-. ROOM HEATING PEAK LOADS Project Name The Miller Residence - Bedroom Addition Date 7/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bar & Breezeway Floor Area 407.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT OF 321.2 X 0.0740 X 42 = 284.8 X 0.3300 X 42 = 48.0 X 0.3400 X 42 = 27.0 X 0.3400 X 42 = 407.0 X 0:0250 X 42 = perim = 56.0 X 0.7300 X 42 = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X - X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = through an interior surface to another room Pa a Total OX ®F X 407 X 10.00 0 347 L/[qfK Area Ceiling Height i ACH A 9 APPROVED Btu/hr R-19 Wall 998 Jeld-Wen Clad Lo/E (SIdGIsDr) 3,947 Jeld-Wen Clad 685 Jeld-Wen Clad 386 R-38 Roof 427 Slab -On -Grade 1,717 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 [DDD Schedule Air Sensible Fraction 8,1ITY61 0 ' TOTAL HOURLY HEAT LOSS FOR ROOM ; 9,211 QATF RY EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2013-07-17710:46:41 I ID: Pae 16 of 19 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Miller Residence - Bedroom Addition 7/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 200.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-19 Wall (N) 147.0 • X 0.0740 X 23.0 = 250 R-19 Wall (S) 157.0 X 0.0740 X 26.0 = 302 R-38 Roof (N) 200.0 X 0.0250 X 56.0 = 280 X X = X X = X X = X X = X X = X X = Page Total 832 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Operable Temp. Square Window ( (N) 0.0 X 16.1 + 20.0 X 16.1 = 322 Fixed Square Window (A) (S) 10.0 X 16.1 + 0.0 X 16.1 = 161 Fixed Square Window (A) (S) 10.0 X 16.1 + 0.0 X 16.1 = 161 X + X - X + X - X + X - X + X - X + X - X + X = Page Total sa3 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.89 X 9.22 X 37 a 324 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,859 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.89 X 9.22 X 0.00376 c C 1TY O F LA Q v 148 Air Sensible CFM ELA AW BUILDING & SAFETY DEP I. +Q)A TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ter; y , , r, , 548 u� 7n'emvPro a.1 by EnemySoft User Number: 3665 RunCode: 2013-07-17710:46:41 ID: Pae 17 f 18 CATE BY - RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Miller Residence - Bedroom Addition 1 7/17/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bar & Breezeway Outdoor Dry Bulb Temperature 112 OF Floor Area 407.0 flz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-19 Wall (N) 80.6 X 0.0740 X 31.0 = 185 R-19 Wall (S) 101.6 X 0.0740 X 38.0 = 286 R-19 Wall (E) 139.0 X 0.0740 X 44.0 = 453 R-38 Roof (N) 407.0 X 0.0250 X 77.0 = 783 X X = X X = X X = X X = X X = Page Total 1,707 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Bi -Fold Doors w/Temp Glass (3) (N) 0.0 X 20.9 + 142.4 X 20.9 = E19.2 2,983 Pocket Temp Glass Door (1) (N) 0.0 X 19.2 + 48.0 X = 920 Fixed Square Window (C) (S) 27.0 X 19.2 + 0.0 X 24.7 = 518 Bi -Fold Doors w/ Temp Glass (3) (S) 135.4 X 20.9 + 7.0 X 27.3 = 3,028 X + X - X + X - X + X - X + X - X +1 X - Page Total 7,449 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.89 X 25.20 X 37 = 886 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,271 Latent Gain Occupants 1.0 Occupants X 2�tuQt LA t+[ 00 BUILDING &SAFETY D Infiltration: X 0.89 X 25.20 X 0.00376 = P R 1,� 0 E 03 Sensible Air Sensible CFM ELA OW PAP lJ V FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM � 03 n TC Ene Pro 5.1 b Ene Soft User Number: 3665 RunCode: 2013-07-17710:46:41 ID: 18