10-0355 (AR) Revision 1 Structural Calcsle -owl STRUCTURAL CALCULATIONS FOR THE MILLER RESIDENCE BATHROOM # 4 ADDITION AT THE ENCLAVE, LOT 12 AND 13 CALLE FLORA LA QUINTA, CA. 92253 JOB # 10-025 1,� 14►�l. CMS ' C�rtr+ ��ta+K' DESIGNER: I OCHOA AND ASSOCIATES CLIENT: Mr. A�4D Mrs. BOB AND SHARON MILLER JUAN CARLOSPHOA AIA. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE %IA BY -c- RECEIVED MAY 2 8 2010 BY: OCHOA AND ASSOCIATES 73-221 HIGHWAY 111, PALM DESERT, CA. 92260 PHONE (760).773-6605 1 FAX (760) 773-6603 A Cy'� v � J JUAN C. OCHOA 0 C-28502 02/28/11 Q OF CA�\� dam' DESIGN CRITERIA 2006 .INTERNATIONAL BUILDING CODE .2007 CALIFORNIA BUILDING CODE SOILS BEARING PRESSURE =1500 PSF (ASSUMED) EXTERIOR WALLS = 15.00 PSF INTERIbR WALLS =10.00 PSF ROOF LOAD (4" per & slope) ROOF DEAD LOAD: CLAY TILE ROOFING = 5.00 PSF SHEATHING' = 2.50 PSF FRANbIING = 2.50 PSF DRYWALL = 2.50 PSF INSULATIONS = 1.50 PSF WSCELLANEOUS = 1.00 PSF TOTAL DEAD LOAD' = 25.00 PSF ROOF LIVE LOAD = 20.00 PSF TOTAL ROOF LOAD = 45.00 PSF DESIGN CRITERIA SEISMIC LOADING LOCATION: LA QUINTA, CA (2IPCODE: 92253) Ss =1.515 Sl = 0.600 Sm =1.010 Sfl, = 0.600 SEISI EC DESIGN CATEGORY D (IBC SECTION 1613.5.6) SITE CLASS D.. (ASSUN ED) (IBC SECTION 1613.5.2) OCCUPANCY'CATEGORY 11. (IBC TABLE 1604.5) SEISMIC ZeORTANCE FACTOR i =1.00 (ASCE 7-05, TABLE 11.5-1) RESPONSE MODIFICATION COEFFICIENT R= 6.5 (ASCE 7-05, TABLE 12.2-1) AT HARi . RAME PANEL R = 6.5 (EF CATALOG 6-08) qT GA EYER STEEL COLUMNR =1.5 (ASCE 7-05, TABLE 12.2-1) REMIND CY FACTOR p =1.30 (ASCE 7-05, SECT: 12.3.4.2) BASES AR V = p x [SmU(1.4 x R)] x W (ASCE 7-05, EQU. 12.8-1 & 12.8-2) BASE S n ;' = 1 �0 x [1..^.10 x 1.01(1:4 x 6.5)1= t3.145W DESIGN -MIND LOADING ASSUMED MOST CONSERVATWE ROOF ANG— 0- = 20° psso =17.8 PSF WIND EXPOSURE, CATEGORY C WU\TD M'ORTANCE FAC i OR 1= 1.00 BASIC WIND SPEED 90 MPH TOPOGRAPHIC FACTOR KzT =1.00 WIND FACTOR pS = X x Kz:r x I x psio (ASCE 7-05, FIGURE 6-2) (ASCE 7-05, SECT. 6.5.6.3) (ASCE 7-05, TABLE 6-1) (ASCE 7-05, FIGURE 6-1) (ASCE 7-05, SECT. 6.5.7.2) (ASCE 7-05, EQU. 6-1) MAXMUM HEIGHT 15 ft (I =1.21) WIND FACTOR ps = 21.54 psf MAX avnW HEIGHT 20 ft (A =1.29) WIND FACTOR ps = 22.97 psf HEIGHT 25 ft (X =1.35) WIND FACTOR ps = 24.03 psi P1LAMAUKI IM:GI?T 30 ft (A. =1.40) WIND FACTOR Fs = 24.92 psf 2 COMPANY PROJECT woodWorks� 4) e M AJ Qf 4 4-91 AV.:%. 2010 1*16 Beamt Design Check Calculation Sheet Suer 2004a LOADS (lbs, Psl. or pff ) Load Type Distribution Magnitude Location [ft] Pat - fv = 47 525 Total 1273 Start End Start End tern 2 Loadl Dead Full Area 25.00(15.00)+ 1.00 Total Defi'n No Load2 Live Full Area Load3 Dead Full Area 15.00((3.00)* No *Tributary WAdth (ft) I MAXIMUM REACTIONS (Ibs) and BEARING LENG,T (in) : "�� Js"a �'2d ..it's.- - C . �: ..a"•"�„�g' �' �,c'••_ .'G- 5a �r":�-_ 'fr� � """",4+^v�-�.� s4 �s ''N+ "? �`2.k'✓<'k�`�''g�� 'E', yi'' + �:C� t r t. :''' � 9"kL 7� ��".h i .r.� YTS -'': �'�€�I.� �7 . - "iF`✓`, �:= 0• ` 3'-6" Dead 748 j 748 Live 525 fv = 47 525 Total 1273 I 1273 Bearing: 2 Live Defl'n 2 LC number Length 1.00 Total Defi'n 1.00 Timber -soft, D.Fir-L, Vo.1, 6W. .Self Weigfd of 7.19pffautomatiew fincludedinloads: Lateral support top= at supports, boftorrf= at '[.pad combmahorrs: ICC4BC; Analysis vs. Allowable Stress (psi) and Deflection (in) using Ds 2001: Criterion Anal sisValue Design Value Anal si /Desi n Shear fv = 47 Frr' = 170 fv/Fv' = 0.27. Bending(+) fb = 482 Ei>' = 1200 fb/Fb' = 0.40 Live Defl'n 0.01 = <L/9 99 0.12 = L/360 0.07 Total Defi'n 0.02 = Q,/999 0.18 = L/240. 0.11 ADDITIONAL DATA: FACTORS: F CD CM Ct CL CF Cfu Cr ;Cfrt Ci Cn LCH Fb'+ 1200 1.00 1.00 1.00 1.000 1.000 1.00 1.00 X1.00 1.00 - 2 Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fcp625 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 i Bending(+): LC$ 2 = D+L, M = 1114 lbs -ft Shear : LCO 2 = D+L, V = 1273, V design = 939 lbsi Deflection: LCO 2 = D+L EI= 122eO6 lb -int Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. (D=dead L --live S --snow W- rind I=impact C=constructio' CLd=concentrated) (All LC's are listed in the Analysis output) DESIGN NOTES: i 1. Please verify that the default deflection tonus are aWmpdde for your application. 2. Sawn lumber bending members shall be laterally supported according to the prov sians of NDS Clause 4.4.1. 3 j I I I Ct I I L z D CA) LATERALANALYSIS SECTION 1 LONGITUDINAL ROOF AVERAGE HEIGHT =11.00 FT. TOP PLATE AVERAGE HEIGHT = 9.00 FT. 20 FT.: MAX.ROOF HEIGHT, WIND FORCE = 2.1154 PSF WINDLO,AD.AT FLOOR = 21.54 x (11.00 - 9.00/2) =140.01 PLF SEISMIC ROOF = 0.145,x ( 25.00x14.00 + 15.00x2x5.0 10.00xlx5) = 79.75 Plf WINIS GOVERNS = 140.01. PLF MAX:SHEAR =140.01 x 14 / 2 x 10 = 98.00 PLF CHORD FORCE =140.01 x 14 x 14 / 8 x 10 = 343.00 LBS USE 1/2" CDX UNBLOCKED 24/0 WITH 8D'S AT 6' , 12" O/C. USE (6) 16D' S PER TOP PLATE SPLICE . SECTION 1 TRANSVERSE ROOF.AVERAGE HEIGHT =12.00 FT. TOP PLATE AVERAGE HEIGHT = 9.00 FT. 25 FT MAX. HEIGHT, VAND LOAD = 21.54 PSF WM LOAD AT FLOOR = 21.54 x (12.00 - 9.00/2) =161.55 PLF SEISMIC ROOF = 0.145 x ( 25.00x16.00 + 15.00x2x10.0+ 10.00xlx5) = 87.00 PLF WIND GOVERNS =161.55 PLF MAX SHEAR =161.55 x 10 / 2 x14 = 57.70 PLF CHORD FORCE = 161.55 x 10 x 10 / 8 x 14 =144.42 LBS USE 1/2" CDX UNBLOCKED 24/0 WITH 8D'S AT 6", 12" -01C. USE (6) 16D' S PER TOP PLATE SPLICE 5 I SHEAR WALL DESIGN SW #1 RIGHT OF BATHROOM4 TOTAL; LOAD =140.01 x14.00/ 2 = 980.00 LBS SHEAR WALE, LENGTH = 9.50 FT AROUND WINDOW SHEAR, WALL = 980.00 / 7.50 =130.67 PLF USE SHEAR WALL, TYPE 10 WITH 5/8" x 12" A. B. AT 48" O/C. MAX DRAG = 138.00 LBS USE (6) 161D'S PER TOP PLATE SPLICE. MAXIMUM UPLIFT =103.91 LBS. HOLDOWNS NOT REQUIRED SW #2 RIGHT OF BDRM #4 TOTAL LOAD =140.01. x'.00/ 2 =®0 LBS � � (o0;14 SHEAR WALL LENGTH = 7.00 FT SHEAR WALL A9,g0.00 / 7.00 =+4&%-PLF 100- d tl USE SIHEARWALL TYPE 11 WITH 5/8" x 12"A- B. AT 32" O/C TO MATCH EXISTING SHEARWAIL, ALONG THIS LINE MAX DRAG = 523.60 LBS USE (6)16D'S PER TOP PLATE SPLICE. W -- MAXIMUM UPLIFT =1 98 LBS USE SIMPSON HDU5 HOLDOWNS EACH END OK, . SW #3. REAR OF BATHROOM4 TOTAL LOAD =161.55 x 10.00/ 2 = 907.75 LBS SHEAR WALL LENGTH =10.00 FT. SHEAR WALL = 907.75 / 10.00 = 90.78 PLF USE SHEAR WALL TYPE 10 WITH 5/8"x 12"A- B. AT 48" O/C MAX DRAG = 464.00 LBS USE (6)16D'S PER TOP PLATE SPLICE. MAXIMUM UPLIFT = 387.15 LBS HOLDOWNS NOT REQUIRED SW #4 FRONT OF BATHROOM 4 TOTAL LOAD = -161.55 x 10.00/2 = 907.75 LBS SHEAR WALL LENGTH = 5.00 + 5.00 =10.00 FT SHEAR WALL = 907.75 / 10.00 = 90.78 PLF USE SHEAR WALL TYPE 10 WITH 5/8 x 12" A B. AT 48" O/C MAX DRAG =19.28 LBS USE (6) 16D'S PER TOP PLATE SPLICE. MAXIMUM UPLIFT = 340.47LBS. HOLDOWNS NOT REQUIRED _ �R1�2A� {�11,YSiS t4�F ,�ec,.�lr� �•o� , ��o =229 w�p .mss 229}e�i�-s� � Zs2.49-P�f 0,00 ��C�zsK.bo)F(��xa�5).�(roa���� as3,�s P�f Om Do 15 �v6Lfj4� pm,c�o— t�c� FOUNDATION DESIGN SOILS BEARING PRESSURE =1500 PSF PER SOILS REPORT MAX LOAD = (45.00x28.0/2) + (15.00x12.00) + (150.00x12x12/144) = 975.00 PLF AT ONE STORY FOUNDATIONS WIDTH REQUIRED = 975.00 / 1500 = 8" 12" WIDE x 12" DEEP CONTINUOUS FOOTINGS WITH (1) # 4 BARS TOP AND BOTTOM. FOOTINCr, CAPACITY = (1500 x 40 x 12) / (12x12) = 5000.00 LBS PADS DESIGN PADS NOT REQUIRED L