Loading...
13667 (SFD) Soil Engineering ReportAPR 15 '94 12:35 BUENA-BERMUDA DUNES 00 -t -'k Earth Systems Consultants tY Southern California April 14, 1994 Mark Cummings J.M. Peters Company P.O. Box 7150 Newport Beach, California 92658-7150 Project: Tract 24890 & Estate Lots Citrus Course LaQuinta, California P.2/2 Buena Engineers Division 79-611 B Country Club Drive Bermuda Dunes, CA 92201 (619) 345-1588 (619) 328-9131 FAX (619) 345-7315 ST -4442-P1 94-04-738 Ref: Soil Engineering Report prepared by Buena Engineers, Inc. dated February 25, 1986; Job No. B -16006-P1, Report No. 86-2-271 . Rough Grading Report prepared by Buena E,tgineers,lne. dated July 17, 1986; Job No. B -16006-P1, Report No. 86-7-223. Rough Grading Report prepared by Soil and Testing Engineers, Inc. dated May 21, 1990; STE 8931087, Report No. 8 As requested, we have reviewed the referenced reports for update purposes and to provide supplemental recommendations for site preparation. Based upon our review, it is our opinion that the recommendations included in the referenced Soil Engineering Report remain valir for the design and construction of the proposed residential structures. Because the majority of the lots within the project have been previously rough graded per the recommendations of the referenced Soil Engineering Report, only minimal grading should be necessary. The lots should be cleared of existing vegetation, then the surface should be, watered and recompacted to correct ally surface looseness which may occur during clearing. Additional remedial grading may be necessary if basements are planned, these cases should be evaluated on an individual basis. The structural values as outlined in the referenced Soil Engineering Report remain valid for the design of the foundations for the proposed residential structures. If there are any questions conc�ining this letter or the referenced reports, please contact the undersigned. Respectfully submitted, Earth Systems Consultants Brett L. Anders Copies: 4 - Mark Cummings 1 - Peter _Rodholm 1 - VTA File I SOIL ENGINEERING REPORT LA QUINTA LODGE IN THE CITY OF LA QUINTA RIVERSIDE COUNTY, CALIFORNIA B -16006-P1 February 1986 I BURnti EnninursAni. 1731-A WALTER STREET • VENTURA, CALIFORNIA 93003 0 PHONE (805) 642.6727 February 25, 1986 B -16006-P1 86-2-271 Landmark Land Company P. O. Box 1000 La Quinta, CA 92253 RE: Proposed La Quinta Lodge City of La Quinta, Riverside County, California Presented herewith is our Soil Engineering Report prepared for the proposed La Quinta Lodge development located near Avenue 52 and Jefferson Street in the City of La Quinta, Riverside County, California. Thin report incorporates the tentative' information supplied our office, and in accordance with the request, recommendations for general site development and foundation design are provided. This report completes our scope of services in accordance with our agreement dated January 23, 1986. Other services which may be required, such as plan review and grading observation are additional services and will be billed according to the Fee Schedule in effect at the time the services are provided. Please contact the recommendations i BUENA ENGINE 44L�, 44 Richard M. Bear Soil Engineer are any questions concerning this report or the C. 24552 0 Exp. 12/31/89 RMB/REB/ms X-15 SER t Copies: 6 -;Landmark Land Company 2 - PS file '1 - VTA file VENTURA (805) 642-6727 Re9nd d Approved QRpFESS/ON f E. a 4, Ra Brannen-� ?'2 Soil Engineer rt m C__ CE 28966 Exp. 3,131/67 / �l C J VlL 1-�EOF CA;-" LANCASTER (805) 948.7538 BAKERSFIELD SANTA BARBARA PALM SPRINGS SAN LUIS OBISPO �R(15� �97.51S/1 (8051 966-9912 16101 198.0111 (RO';1544-61R7_. R TABLE OF CONTENTS INTRODUCTION.......................................................... SITESETTING........................................................... FIELD INVESTIGATION .......... ....... ............................. . LABORATORY TESTING ................................................. SOIL CONDITIONS....................................................... LIQUEFACTION .................................. ..................... CONCLUSIONS.......................................................... SITE DEVELOPMENT AND GRADING ...................................... SiteGrading- General ............................................... GolfCourse........................................................ One and Two Story Structures ........................................ Commercial Buildings and Clubhouse .................................. Hotel.............................................................. Swimming Pools and Spas ............................................ Miscellaneous Structures ............................................. STRUCTURE DESIGN .................................................... Foundations........................................................ Slabs -on -Grade ..................................................... Settlement Considerations ........................................... Frictional and Lateral Coefficients .................................... Slope Stability......... ........................................... Paving Sections ..................................................... AdditionalServices .................................................. LIMITATIONS AND UNIFORMITY OF CONDITIONS .......................... APPENDIX A Summary of Test Results Table 29-A APPENDIX B Standard Grading Specifications APPENDIX C Site Plan Log of Borings Trench Logs 1 1 2 3 3 4 4 5 5 6 6 7 7 8 8 8 8 9 10 10 10 11 11 12 February 25, 1986 -1- B- 16006-P 1 86-2-271 INTRODUCTION This report presents results of a Soil Engineering study performed for the proposed La Quinta Lodge development in the City of La Quinta, Riverside County, California. A. It is our understanding that the proposed development will include a variety of structures including single family residences, condominiums, commercial buildings, and a hotel. Construction types will probably include wood frame and stucco, concrete tilt -up and masonry buildings. The exact foundation types or locations of the buildings are not known at this time. B. For single family residences and condominiums structural considerations for building column loads of up to 15 kips and a maximum wall loading of 1.5 kips per lineal foot were used to as a basis for the recommendations. C. For commercial construction structuralconsideration for column loads of up to 50 kips (dead plus live load) and a maximum wall loading of 3.0 kips per linear foot were used as a basis for recommendations. D. For the hotel structures column loads in the range of 100 kips and wall loads of up to 3..0 kips per lineal foot were used as a basis for recommendations. E. If loads are determined to exceed these estimated values the soil engineer should be contacted because such changes may affect our recommendations. SITE SETTING The site consists of 418 acres in Riverside County, California. The site is typical desert with erosional swales and minor duning. The site of the proposed development included in this report is bounded by the extension of Avenida Ultimo on the north, 52th Avenue on the south, Calle Rondo on the west, and Jefferson Street on the east, - in the City of La Quinta, Riverside County, California. A. The site is basically flat with general drainage toward the southeast. The majority of the property is presently used for agricultural, purposes, including growing citrus and dates. February 25, 1986 -2- B- 16006-P 1 86-2-271 B. There are several residences and farm related buildings on the site. Utilities serve these improvements and there is a system of underground irrigation lines. C. There has been previous grading to level the land for agricultural use and to create raised areas for residences. D. There are several sewage holding ponds in the far western part of the property. FIELD INVESTIGATION Exploratory borings were drilled and backhoe trenches excavated for observing the soil profile and obtaining samples for further analysis. A. Twelve (12) borings were drilled for soil profiling and sampling, to a maximum depth of forty-one (41) feet below the existing ground surface. In addition, eleven backhoe trenches were excavated to a maximum depth of thirteen (13) feet. The field work was conducted between January 31, and February 5, 1986, using a CME 55 drilling rig and a backhoe. B. Samples were secured within the test borings with a two and one-half (2y:) inch diameter ring sampler (ASTM D 3550, shoe similar to ASTM D-1586). The samples were obtained by driving the sampler with a 140 pound hammer, dropping 30 inches, in accordance with ASTM D 1586. C. Moisture and density were measured at selected intervals in the backhoe pits in accordance with ASTM 2922-81 and ASTM 3017-78 Nuclear Density Test Procedure. D. Bulk samples of the soil types encountered were gathered from the auger cuttings for classification purposes. E. The final logs represent our interpretation of the contents of the field logs, and the results of the laboratory tests and observations of the field samples. The final logs are included in an appendix of this report. The stratification lines represent the approximate boundaries between soil types and the transition may be gradual. BUENA ENGINEERS, INC February 25, 1986 -3- B -16006-P1 86-2-271 LABORATORY TESTING After a visual and tactile classification in the field, samples were returned to the laboratory, classifications were checked, and a testing program was established. A. Samples were reviewed along with field logs to determine which would be further analyzed. Those chosen were considered representative of soils which would• be exposed and/or used in grading and those deemed within building influence. B. In-situ moisture content and unit dry weights for the core samples were developed in accordance with ASTM D 2937: C. The relative strength characteristics of the subsurface soils were determined from the results of direct shear tests. Specimens were placed in contact with water at least 24 hours before testing, and were then sheared under normal loads ranging from 0.5 to 2.0 KSF. D. Settlement potential was evaluated from the results of consolidation tests performed in accordance with ASTM D 2435. E. Classification tests consisted of Expansion Index (UBC Standard 29-2), Maximum Density -Optimum Moisture (ASTM D 1557), and hydrometer analysis (California Test Method 203 and ASTM D 422). F. Refer to Appendix A for tabular and graphic representations of the test results. SOIL CONDITIONS As determined by the borings, site soils were found to consist primarily of silty very fine sands with some silts lenses. A. The soils encountered were primarily poorly graded silty very fine to fine sands.. These soils were sometimes interbedded with cleaner sands below a depth of five (5) feet. Only occasional silt lenses were encountered. February 25, 1986 '-4- B- 16006-P 1 86-2-271 B. Expansion tests indicate some soils to be in the "low" expansion category in accordance with UBC Table 29-C. However,' blending during grading should result in "very low" expansion characteristics. Lots should be categorized by soil type and expansions checked at the completion of grading. One soil was found to be highly expansive showing an expansion index of 93. However, this soil is found in comparatively small quantities and should not affect overall expansion results. C. In general soils were loose to only medium compact throughout the depths investigated. In the upper five (5) feet relative compaction averaged about 81 to 82 percent. D. Consolidation 'tests showed isolated moderate hydroconsolidation potential, but considerable settlement potential. E. Free water was not encountered to the maximum drill depth of forty-one (41) feet. LIQUEFACTION For liquefaction to occur soils must be below the water table. Free water was not encountered to a drill depth of forty-one (41) feet during this investigation. Ground has been reported to be found at depths greater than seventy '(70) feet below the ground surface (Leighton and Associates, Present No. 5840700-01, February 8, 1985). In consideration of the deep water table, liquefaction does not seem to be a potential for the site. CONCLUSIONS Test results indicate that site soils are loose with the sands being dry and the silts moist. To improve bearing values and limit settlement soil recompaction will be. required. The depth of recompaction will vary by structure type andestimated loading. It is concluded that the site is suitable for the intended development. February 25, 1986 -5- B- 16006-P 1 86-2-271 SITE DEVELOPMENT AND GRADING Prior to any earth moving operations, areas to be graded should be cleaned of vegetation and other deleterious materials. Appendix B, "Standard Grading Specifications" contains specific suggestions for removal and disposal of deleterious substances and, as such, forms a part of these Site Development and Grading Recommendations. A. Site Grading - General 1. Testing showed that in-place densities are low. Therefore, recompaction of the bearing soils is recommended. 2. The existing ground surface should be initially prepared for grading by removing vegetation, noncomplying fill, existing uncertified fill, or other incompetent material. No compacted fill should be placed unless the underlying soil has been observed by the soil engineer or his technical representative. 3. Removal of trees, structures, existing utilities and irrigation lines may create fairly deep disturbances that should be properly backfilled with compacted soil. Roots larger than one-half inch in diameter should be removed and hauled away. Organics may be burned or hauled away. If burned, the ashes should be removed. 4. Soils and organics at the bottom of the sewage holding ponds should be removed and blended with sandy soils. Concentrations of organics will not be allowed. 5. Previously removed soils, once cleaned of rocks larger than eight (8) inched in greatest dimension, and other deleterious material, may be placed in thin layers and mechanically compacted back to finish grade. 6. Fill and backfill should be compacted to the minimums of ninety (90) percent of maximum dry density obtainable by the ASTM D 1557 test method. Specific requirements are included in Appendix B, "Standard Grading Specifications" and Chapter 70 of the Uniform Building Code. BUENA ENGINEERS February 25, 1986 -6- B -16006-P1 86-2-271 7. It is anticipated that during grading a loss of approximately two tenths of a foot due to. stripping, and a shrinkage factor of about fifteen percent (15%) for the upper five (5) feet of soil may be used for quantity calculations. This is based on compactive effort needed to produce an average degree of compaction of approximately 93 to 94 percent, and may vary depending on contractor methods. Subsidence is estimated at between two-tenths to three -tenths of a foot. 8. Areas around the structures should be graded so that drainage is positive and away from the structures. Gutters and down spouts should be used to convey water out of the foundation area. 9. It is recommended that the soil and foundation engineer be retained to provide soil engineering services during construction of the excavation and foundation phases of the work. This is to observe compliance with the design concepts, specification and recommendations and to allow design changes in the event that subsurface conditions differ from these anticipated prior to start of construction. B. Golf Course 1. In the golf course areas, the areas to receive fill, after being cleared of organics and other foreign materials, should be scarified to near optimum moisture and the surface compacted, using heavy vibrating equipment, to a minimum of eighty-five percent (85%) of maximum density. Fill materials should be placed in thin layers, moistened to near optimum and then compacted to a minimum of ninety percent of maximum density. 2. In cut areas the finished grade should be scarified, moistened to near optimum and then compacted, using vibrating equipment, to at least eighty-five percent (85%) of maximum density. C. One and Two Story Structures (Wood frame and Stucco) 1. Building areas should be undercut to a depth of two (2) feet below original grade or two (2) feet below the bottom of footings, whichever is deeper. The exposed surface should be icompacted by means of heavy vibrating equipment so that the upper one foot is. at least ninety (90) percent of February 25, 1986 -7- B -16006-P1 86-2-271 maximum density. Fill material should then be placed in thin layers* at near optimum moisture and compacted to a minimum of ninety percent of maximum density. 2. These grading requirements apply to building areas and at least five feet beyond building limits. D. Commercial Buildings and Clubhouse 1. Soils within the building area and at least ten feet beyond the building limits should be removed to a minimum of three (3) feet below present grade or four (4) feet below the bottom of the footings, whichever is lower. The exposed surface should be conditioned to near optimum moisture and compacted by means of heavy vibrating equipment so that the upper one foot is at least ninety (90) percent of maximum density. Fill material may then be placed in thin layers at near optimum moisture and compacted to a minimum of ninety (90) percent of maximum density. E. Hotel 1. The scope of earth work for the hotel is dependent on the magnitude of the column loads. We have assumed that loading will be in the range of 100 kips, which might be the maximum expected for a two story structure. Further, if grading is accomplished prior to developing plans for the hotel the entire building pad area to a distance of ten (10) feet beyond any proposed building limit should be removed and recompacted. 2. Soils should be removed to a depth of four (4) feet below the bottom of footings or three (3) feet below original grade whichever is deeper. The exposed surface should be brought to near optimum moisture and compacted to a minimum of ninety (90) percent of maximum density. Removed soils may then be replaced as compacted fill back up to finish grade. 3. If , the hotel is planned to be a lighter structure, the recommended earthwork can be reviewed and modified. BUENA ENGINEERS, INC WE February 25, 1986 • -8- B -16006 -PI 86-2-271 F. Swimming Pools and Spas I. Where swimming pools and spas are bottomed below the depth of compaction it is recommended that the pool and spa excavation be deepened two additional feet. The exposed surface should be scarified, moisture conditioned and be recompacted. Previously removed soils may then be recompacted up to the bottom of the pool or spa. G. Miscellaneous Structures 1. Preparing the areas for miscellaneous structures such as foot bridges, entrance posts, sign foundations, etc., should be as noted for single story structures. STRUCTURE DESIGN A. Foundations Conventional continuous footings and/or isolated pad footings may be used for support of structures. 1. All pad and continuous footings or load bearing grade beams should be founded on firm compacted soil as recommended elsewhere in this report. 2. A minimum footing depth of twelve inches (1211) below lowest adjacent finish grade should be maintained for one story structures and eighteen (18) inches below lowest adjacent grade should be maintained for two story and commercial structures. 3. Continuous foundations satisfying the above conditions may be designed for the following values assuming a twelve (12) inch deep one (1) foot wide footing: 1100 psf, for dead plus reasonable live load. 4. Pad foundations satisfying the above conditions may be designed for the following values assuming a two by two (2 x 2) feet by eighteen (18) inch deep footing: 1700 psf for dead plus reasonable live load. BUENA ENGINEERS, INC February 25, 1986 ` -9- B -16006-P1 86-2-271 5. The above dead plus live load value may be increased by 300 psf for each additional six (6) inches of depth and by 200 psf for each additional foot of width. Bearing values should not be increased above 2500 psf without approval of the soils engineer. 6. Allowable bearing values for dead plus live loads may be increased by one- third when wind and seismic forces are included. 7. Allowable bearing values are net (weight of footing and soil surcharge may be neglected) and are applicable for dead plus reasonable live loads. 8. Table 29-A gives specific minimum requirements for width, depth and reinforcing. The applicable expansion category should be determined at the completion of rough grading. It is anticipated that the "very low" category will apply. Other requirements may be more stringent and would govern. 9. Lateral loads may be resisted by soil friction on floor slabs and foundations and by passive resistance of the soils acting on foundation stem walls. Lateral capacity is based partially on the assumption that any required backfill adjacent to foundations and grade beams is properly compacted. 10. Foundation excavations should be visually observed by the soil engineer during excavation and prior to placement of reinforcing steel or concrete. Local variations in conditions may warrant deepening of footings. B. Slabs -on -Grade 1. Concrete slabs -on -grade should be supported by firm compacted soil placed in accordance with applicable sections of this report. 2. Slabs on grade should at a minimum be reinforced with 6X6 No.10/No.10 welded wire fabric. Actual reinforcement should be in accordance with Table 29-A based on expansion indicies determined at the end of grading. 3. Commercial slabs should be designed for anticipated loading during use or construction, whichever governs. 4. It is recommended that perimeter slabs (sidewalks, patios, etc.) be designed relatively independent of footing stems (free floating) so that settlement and/or expansion should not cause cracking. 5. Slabs should be underlaid with. two (2) inches of sand and an appropriate vapor barrier in areas where floor wetness would be undesirable. The February 25, 1986 10- B- 16006-P 1 86-2-271 membrane should be covered with the two inches of sand to protect it during construction. The sand should be lightly moistened just prior to placing the concrete. The total thickness of sand will need to be increased to four (4) inches of soils at the end of grading are found to fall above the "very low" expansion range. C. Settlement Considerations 1. Expected maximum settlement of less than one (1) inch is anticipated for foundations and floor slabs designed and placed on recompacted soil as recommended. 2. Differential settlement between adjacent load bearing members is anticipated to be less than one-half (Y2) inch. 3. The majority of anticipated settlements should occur during construction with post construction settlement being minimal. D. Frictional and Lateral Coefficients 1. Resistance to lateral loading may be provided by friction acting on the base of foundations. A coefficient of friction of 0.45 may be applied to dead load forces. 2. Passive resistance acting on the sides of foundation stems (300 pcf, equivalent fluid weight), may be included for resistance to lateral load. 3. A one-third (1/3) increase in the quoted passive value may be used for wind or seismic loads. 4. When passive resistance of soils against grade beams and the frictional resistance between the floor slabs and the supporting soils are combined, the friction factor should be reduced to 0.30 of dead load forces. 5. For cantilever retaining " walls backfilled with compacted native soil, a pressure of an equivalent fluid weighing 35 pcf may be used for well drained, level backfill conditions, plus the effect of any surcharge loads. E. Slope Stability Slope stability analyses have not been performed because of the anticipated low height (less than three (3) feet) of any slopes. In general, it may be assumed that fill slopes should be stable at 2 horizontal to 1 vertical. BUENA ENGINEERS, INC February 25, 1986 _11- B -16006-P1 86-2-271 F. Paving Sections The following paving sections are based on an estimated "R" value of 50 for the soil on the project. Final paving sections should be based on "R" values measured on actual subgrade soils sampled at the end of rough grading and actual paving section may be less or more than those listed below. In some cases the City's minimum section may exceed provided designs and would govern. 1. Arterial Streets T1=7 "R"=50 3 inches AC on 6.5 inches Class II Base 2. Collector Streets TI=6 "R"=50 Use 3 inches AC on 4.5 inches of Class II Base 3. Residential Streets TI=S "R"=50 Use 2.5 inches AC on 3.5 inches of Class II Base or the City minimum, whichever is larger. G. Additional Services This report is based on the assumption that an adequate program of monitoring and testing will be performed during construction to check construction compliance with these recommendations. These tests would be additional services provided by our firm. The costs of these services are not included in our present fee arrangements. The recommended tests and observations include, but are not necessarily limited to the following: 1. Review of the final design to verify compliance with the recommendations of this report. 2. Observation and testing during site preparation, grading and placement of engineered fill. 3. Consultation as required during construction. BUENA ENGINEERS, INC February 25, 1986 .-12- B- 16006-P 1 86-2-271 LIMITATIONS AND UNIFORMITY OF CONDITIONS The analysis and recommendations submitted in this report are based in part upon the data obtained from the twelve (12) borings drilled and eleven (11) trenches excavated on this site and on experience and judgement. The nature and extent of variations between the borings may not become evident until construction. If variations then appear evident, it will be necessary to reevaluate the recommendations of this report. Findings of this report are valid as of this date; however, changes in conditions of a property can occur with passage of time whether they be due to natural processes or works of man on this or adjacent properties. In addition, changes in applicable or appropriate standards occur whether they result from legislation or broadening of knowledge. Accordingly, findings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and should not a relied upon after a period of one year. In the event that any changes in the nature, design or location of the development or buildings are planned, the conclusions and recommendations contained in this report shall not be considered valid unless the changes are reviewed and conclusions of this report modified or verified in writing. This report is issued with the understanding that it is the responsibility of the owner, or of his representative to insure that the information and recommendations contained herein are called to the attention of the architect and engineers for the project and incorporated into the plan and that the necessary steps are taken to see that the contractor and subcontractors carry out such recommendations in the field. The soil engineer has prepared this report for the exclusive use of the client and authorized agents. This report has been prepared in accordance with generally accepted soil and foundation engineering practices. No other warranties either expressed or implied are made as to the professional advice provided under the terms of this agreement, and included in the report. .BUENA ENGINEERS, INC February 25, 1986 .-13- B -16006-P 1 86-2-271 It is recommended that the soil engineer be provided the opportunity for a general review of final design and specifications in order that earthwork and foundation recommendations may be properly interpreted and implemented in ' the design and specifications. (If the soil engineer is not accorded the privilege of making this recommended review, he can assume no responsibility for misinterpretation of his recommendations.) END OF TEXT Appendices BUENA ENGINEERS, INC. APPENDIX A Summary of Test Results Table 29-A February 25, 1986 �A I B -16006 -PI 86-2-271 TEST RESULTS BORING/DEPTH 1@0'-2' 1@6'-9' 2@5'-10' 3@9'-12' 6@20' 6@30' 5@ 12'-14' USCS SM MH SP ML SOIL DESIGNATION Al B2 A3 B1 MAX. DEN. (pcf) 113.6 120.8 112.3 116.6 OPT. MOIS. W 13.1 12.2 11.5 12.1 ANG. OF INT. FRIC. 25.20 32.40 24.1 0 23.40 38.50 COHESION (psf) 268 94 304 33 17 EXPANSION INDEX 22 0 93 GRAIN SI'_F DISTRIBUTION Gravel 0.0 0.0 0.0 Sand 52.7 33.7 80.7 Silt 40.6 46.6 13.1 Clay 6.7 19.7 6.2 SOIL DESCRIPTION: A 1: Light brown to light grey very silty very fine sand A2: Grey to brown slightly clayey very fine sandy silt A3: Tan to light grey slightly silty very fine to fine sand B1: Light brown very fine sandy silt B2: Light brown slightly clayey very fine sandy silt B3:. Light brown to brown silt BUENA ENGINEERS, INC. February 25, 1986 -19- B -16006 -PI 86-2-271 BACKHOE TRENCHES BUENA ENGINEERS, INC. RELATIVE BORING & DEPTH DRY DENSITY % MOISTURE COMPACTION 1 @ 1.0 98.8 12.1 87 3.0 87.2 24.2 77 5.0 97.7 8.8 87 2 @ 1.0 97.3 1.0 86 3.0 97.6 2.8 86' 5.0 98.2 3.2 86 3 @ 1.0 95.1 2.8 84 3.0 89.8 6.7 79 5.0 91.1 7.9 80 4 @ 1.0 93.5 4.7 82 3.0 85.9 3.7 76 5.0 89.3 4.2 79 5 @ 1.0 93.1 8.2 82 3.0 88.2 10.2 79 5.0 96.0 7.0 -- 6 @ 1.0 86.5 9.5 76 3.0 92.9 4.7 82 5.0 88.5 7.3 -- 7 @ 1.0 93.8 0.5 83 3.0 90.6 0.8 80 5.0 -- -- -- 8 @ 1.0 97.8 2.2 86 3.0 89.5 7.3 -- 5.0 83.2 2.6 -- 9 @ 1.0 99.6 3.7 88 3.0 87.8 10.5 -- 5.0 88.6 12.1 -- 10 @ 1.0 90.6 21.7 80 3.0 93.2 25.9 -- 5.0 88.6 12.1 -- 11 @ 1.0 96.8 9.0 85 3.0 87.2 13.0 -- 5.0 75.2 18.0 -- BUENA ENGINEERS, INC. February 25, 1986 -A 2- B -16006 -PI 86-2-271 IN-PLACE DENSITIES RELATIVE BORING & DEPTH DRY DENSITY % MOISTURE COMPACTION 1 @ 1.0 86.5 9.3 76 3.0 88.6 7.8 78 5.0 88.9 29.5 74 10.0 82.6 39.6 68' 15.0 107.7 5.2 -- 2 @ 1.0 93.2 3.8 82 3.0 102.1 4.0 91 5.0 96.3 4.1 86 10.0 94.3 4.6 84 15'.0 81.4 25.8 72 3 @ 1.0 96.5 3.6 86 3.0 92.7 3.8 82 5.0 92.6 3.2 82 10.0 83.2 38.7 71 15.0 76.1 8.6 67 20.0 86.2 36.4 74 30.0 93.8 10.3 83 40.0 86.0 36.8 -- 4 @ 1.0 85.9 34.0 -- 3.0 84.4 12.0 75 5.0 97.1 6.2 -- 10.0 85.3 19.5 -- 15.0 85.5 11.5 -- 20.0 93.3 29.7 -- 30.0 96.7 23.2 40.0 106.5 9.9 95 5 @ 1.0 80.1 9.4 69 3.0 94.1 4.2 84 5.0 115.6 4.2 99 10.0 91.4 27.4 81 15.0 94.0 27.4 81 20.0 91.5 7.1 81 6 @ 1.0 78.8 8.9 70 3.0 92.6 13.9 82 5.0 89.1 4.4 79 10.0 102.4 12.2 91 15.0 88.4 12.2 79 20.0 96.8 17.5 -- 30.0 95.9 6,7 __ TABLE NO. 29-A MINIMUM FOUNDATION REQUIREMENTS 10 Footings for Slab do Raised Floor Systems (2) (5) (10) Concrete Slabs 3Y:" Minimum Thickness v All Peri- Interior -foot- Reinforce - cv meter ings for slab ment for Premoistening Weighted Footings and raised continuous control for soils Piers under Expansion ° s (6) floors (6) footings Reinforce- Total under footings, raised floors Index I" t-- to c W c (3) (8) ment (4) thickness piers and slabs O Eo o Depth below natural of sand (5) (6) °1Z vi U. li surface of ground and finish grade INCHES 0-20 1 6 12 6 12 12 None 6x6- Moistening of Piers allowed Very Low 7(Non-Ex- 2 8 15 7 18 18 Required 10/10 ground prior to for single ;pansive) 3 10 18 8 24 24 WWF 2" placing concrete floor loads recommended only 1 6 12 6 15 12 120% of optimum 21-50 2 3 8 10 15 18 7 8 18 24 18 24 144 top 6x6- moisture content to a depth of Piers allowed for single Low and bottom 10/10 4" 21" below lowest floor loads WWF adjacent grade. only Testing Required l 6 12 6 21 12 144 top 6x6- 130% of optimum 2 8 12 8 21 '18 and bottom 6/6 WWF moisture content 51-90 3 10 15 8 24 24 or #3 to a depth of 27" Piers not Medium i @ 24" e.w. 4" below lowest allowed ars @ 24" in ext, footing adjacent grade. and bent 3' into slab (9) Testing Required 1 6 12 6 27 12 145 top 6x6- 140%. of optimum 2 8 12 8 27 18 and bottom 6/6 WWF moisture content 91-130 3 10 15 8 27 24 or #3 to a depth of 33" Piers not High @ 24" e.w. 4" below lowest allowed adjacent grade. ars 4" in ext. footing and bent 3' into slab (9) Testing Required Above 130 Very High Special Design by Licensed Engineer/Architect February 25, 1986 •A 2- B- 16006-P 1 86-2-271 BORING & DEPTH 7 @ 1.0 3.0 5.0 10.0 15.0 8 @ 1.0 3.0 5.0 10.0 15.0 9 @ 1.0 3.0 5.0 10.0 15.0 10 @ 1.0 3.0 5.0 10.0 15.0 11 @ 1.0 3.0 5.0 10.0 15.0 20.0 30.0 12 @ 1.0 3.0 5.0 10.0 15.0 IN-PLACE DENSITIES DRY DENSITY 93.9 100.4 98.8 102.1 86.0 90.5 81.7 94.6 94.0 85.7 91.7 81.5 85.6 96.0 91.0 89.7 99.3 83.7 90.4 88.4 88.4 87.2 89.5 94.7 92.0 99.1 % MOISTURE .BUENA ENGINEERS, INC 3.1 3.1 4.3 4.1 11.2 28.4 11.1 22.5 14.0 31.2 5.7 7°: 1 7.3 23.2 16.0 4.9 2.6 12.4 4.7 2.7 2.7 6.4 5.6 2.8 28.9 1.2 1.4 1.2 3.3 RELATIVE COMPACTION 84 89 88 91- 76 83 84 73 82 73 76 81 80 88 80 80 84 88 FOOTNOTES TO TABLE 29-A 1. Premoistening is required where specified in Table 29-A in order to achieve maximum and uniform expansion of soils prior to construction and thus limit structural distress caused by uneven expansion and shrinkage. Other systems which do not include premoistening may be approved by the Building Official when such alternatives are shown to provide equivalent- safeguards against adverse effects of expansive soils. 2. Underfloor access crawl holes shall be provided with curbs extending not less than six (6) inches above adjacent grade to prevent surface water from entering the foundation area. 3. Reinforcement for continuous foundations shall be placed not less than 3" above the bottom of the footing and not less than 3" below the top of the stem. 4. Reinforcement shall be placed at mid -depth of slab. 5. After premoistening, the specified moisture content . of soils shall be maintained until concrete is placed. Required moisture content shall be verified by an approved testing laboratory not more than 24 hours prior to placement of concrete. 6. Crawl spaces under raised floors need not be premoistened except under interior footings. Interior footings which are not enclosed by a continuous perimeter foundation system or equivalent concrete or masonry moisture barrier complying with Section UBC 2907 (b) in this ordinance shall be designed and constructed as specified for perimeter footings in Table 29-A. 7. A grade beam not less than 12" x 12" in cross section, reinforced as specified for continuous foundations in Table 29-A, shall be provided at garage -door openings. 8. Foundation stem walls which exceed a height of 3 times the stem thickness above lowest adjacent grade shall be reinforced in accordance with Sections 2418 and 2614 in the UBC or as required by engineering design, whichever is. more restrictive. 9. Bent reinforcing bars between exterior footing and slab shall be omitted when floor is designed as an independent, "floating" slab. 10. Fireplace footings shall be reinforced with a horizonal grid located 3" above the bottom of the footing and consisting of not less than No. 4 bars at 12" on center each way. Vertical chimney reinforcing bars shall be hooked under the grid. MOISTURE CONTSNT IN PS%CfrNT OF DRY WSIGWT F - g 12 14 16 ' LL j V m OPTIMUM MOISTURE 13.1 CURVES BUENA ENGINEERS INC. Plate MOISTUR* CONTIRNT IN PSRCfrNT OF DRY WSIGIIT p 121 LL u m 3 ti IV 119 4 ' z = 117 } H h 2 M&TNOD OF - COMPACTION. ASTM D-1557-78, Method A or C SO11- TYPG MAXIMUM DONSITY OPTIMUM MOISTURE B2 (YIH) 120.8 pcf 12.2 (1 @ 6-9') MAXIMUM Drak&ITY—OPTIMUM MOISTURE CURVES BUENA ENGINEERS INC. Plate MOISTUR* COMTSNT IN PSRCLNT OF DRY WSIGIIT 8 10 12 14 LL V m 3 OI 112 z 7 S = 110 } I- >. } 108 g M&TNOD Or-COMPACTION. ASTM D-1557-78, Method A or C •OIL. TYPir MAXIMUM DENSITY OPTIMUM MOISTURE A3 (SP) 112.3 pcf 11.5 (2 @ 5-10') MAXIMUM DGNSITY — OPTIMUM MOISTURE CURVIES BUENA ENGINEERS INC MOISTURE CONTONT IN PIIC6MT OF DRY W*IGNT 8 0 12 416 LL U m 3 IL 118 d = 116 Fr - h Z 114 g MSTWO0 OF COMPACTION. ASTM D-1557-78, Method A or C 1011. TYPGr MAXIMUM DIMITY QPTIMUM MOISTURE B1 (ML) 116.6 pcf 12.1 (3 @ 9-12') (5 @ 12-14') MAXIMUM CIGNSITY - OPTIMUM MOISTURE CURVES BUENA ENGINEERS INC. LOAD IM KIPS PSR SQUAQir FOOT ' u Rebound Z 0:00 1 @ 3' Ef ect of Addng Waterer oC W IL W 2 U 0.02 Z Z 0 F- 0.04 O_ J O n Z OU 0.06 CONSOLIDATION DATA BUENA ENGINEERS INC. ' i Rebound 1 @ 3' LOAO IN KIPS PiR SQUARE FOOT a-2 0.4 0-6 e e 1_o cc W a a W 2 U Z 0.02 :. Z 0 H 0.04 J h Z O v 0.06 1.0 2z 4A &Z 04 KX0 CONSOLIDATION DATA BUENA ENGINEERS INC. Eff ct of Addi g Water e , Rebound I 1 @ 5' CONSOLIDATION DATA BUENA ENGINEERS INC. LOAD 111 KIPS PSR SQUAQF FOOT 0.3 0.4 0.4 0A 1.0 U z 0.00 a W 2 Z 0.02 z z 0 F - Q 0.04 O J O A z O v 0.06 M: 2.0 2.0 LD &Z 8.0 lao CONSOLIDATION DATA BUENA ENGINEERS INC. �:.:.I:.'� .�..._.�..�._...,...^v.:aL':\.. .2"�.'.�. t:.�. ::'.4-: :l"-�-�....�.n :SL'_..........:LT:.'.:Lti:.�l...:.C:ir_...5__.�SL"i=:.�..�d�Z: "" -..�::_L�=...:�.:..:...•"LL.^_......� Ef ect of Add'ng Water i Rebound 4 @ 3' CONSOLIDATION DATA BUENA ENGINEERS INC. �:.:.I:.'� .�..._.�..�._...,...^v.:aL':\.. .2"�.'.�. t:.�. ::'.4-: :l"-�-�....�.n :SL'_..........:LT:.'.:Lti:.�l...:.C:ir_...5__.�SL"i=:.�..�d�Z: "" -..�::_L�=...:�.:..:...•"LL.^_......� LAAO 0.3 0.4 0.4 IN KIPS PiR XQUA & 0.6 1.0 2.0 FOOT 2.0 lD 6.0 eD K10 o U Z 0.0 Rebound oC W 6 @ 3' CL A W Effe t of Addin Water Z 0.0 Z Z 0 I�- Q 0.0 O_ J 0 A Z O 0.0 0.0 CONSOLI DATION DATA BUENA ENGINEERS INC. • o 0 Rebound 6 @ 3' LOAD IM KIPS PiR SQUARir FOOT 0.2 0.4 0.4 O.0 !.O 2.0 2D 4D iD 0.0 KLO U Z 0.00 of a a W 2 U Z 0.02 ►, Z 0 N Q 0.04 O lm CONSOLIDATION DATA BUENA ENGINEERS INC. Effec of Adding Water o 0 Rebound 6 @ 10' CONSOLIDATION DATA BUENA ENGINEERS INC. LOAD IN KIPS PiQ SQUAQir FOOT 0.2 0.4 0.4 0.6 1.0 1.0 2z sd iD e.o no 0 Z 0.00 6 @ 10' W a Effect of Adding Water a W 2 U 0.02 Z Z 0 F- Q 0.04 O J 0 0 Z O V 0.06 0.08 CONSOLI DATION DgTA BUENA ENGINEERS INC. 0 6 @ 10' LOAD IM KIPS PfiR 94UARgr FOOT 0.2 0.4 0.6 O -s 1-0 2 f% A P% Ad% 0.0( 0.0� Of 0 0. U 0.0< 2 z z 0 0 4 0.0E 3 0 or) z 8 0.08 0.1c 6.0 8.0 NX0 CONSOLIDATION DATA BUENA ENGINEERS INC. Effect of Adding Water Rebound 8 @ 3' I tj CONSOLIDATION DATA BUENA ENGINEERS INC. LOAD IM KIPS PGR SQUARfr FOOT 0.3 0.4 0.4 OJs 1.0 LO 3.0 AD 4.0 e.0 9X0 u Effect of Adding Water = 0.00 oC a a W Z Z 0.02 Z Z 0 H Q 0 0.04 Rebound J 8 5' 0 D Z 0.06 CONSOLIDATION DATA BUENA ENGINEERS INC. @ 17� L.OAO IM KIPS PSR SQUARir FOOT 0.2 0.4 0.6 0.6 1.0 LO 2.0 i D e.0 lao u z 0.00 o[ Effect of. dding Water a A U 0.02 Z ' z Z O Q 0.04 O J O h z 0.06 CONSOLIDATION DATA BUENA ENGINEERS INC. W W Rebound 9 3' @ 6 LAAO IN KIPS PSR &QUARiF FOOT *.s o.4 0.4 0A 1.0 to so 8.0 KXO 9 @ ' U Z 0.00 c[ W a w Effe t of Adding Water 2 Z 0.02 Z Z 0 1- Q 0.04 O J O. n Z UO 0.0 CONSOLIDATION DATA BUENA ENGINEERS INC. 6 Rebound 9 @ ' LOAO IN KIP: PER SQUARre FOOT 0.3 0.4 0.0 0.6-11.0 i0 3.0 < O 6D 0.O no 2 U Z 0.00 oC dl CL 113 W S U 0.0 Effe t of Add in Nater. Z Z O 0 0.0 J O A Z V 0.0 0.0 Rebound 11-@ 3' GONSOLI DATION DATA BUENA ENGINEERS INC. 4.0 3.5 3.0 2.5 SHEAR114G ST RESS IN KIPS 2.0 PER SQUARE FOOT U I .0 0.`, 0 ivI Semple Remolded at 90XV of Maximum Density ❑ Sample Run at In -Place Density DIRECT SHEAR DATA Semple Angle of Internal Friction Cohesion B2(1 @ 6-9') 25.2° 268 psf A3(2 @ 5-10') 32.4° 94 psf NORML LOAD IN KIP; PER SQUARE FOOT A 1n t5 1)n 11c 2A i Ii I I 1 2 @ 5-10' 1 @ 6-9' i i 4.0 3.5 w 2.5 SHEARING STRESS IN KIPS 2.0 PER SQUARE FOOT 1.; 1.0 0.; 0 n2 Sample Remolded st 90.,., of tlzzimum Density ❑ Sample Run at In -Place Density DIRECT SHEAR DATA Sample /angle of Internal Friction Cohesion (3 @ 9-12") 24.1° 304 psf .(5 @ 12-14') NORMAL LOAD IN KIPS PER SDI -',RE FOOT 4.0 3.5 3.0 2.5 SHEARM STRE. S IH KIPS 2.0 PER SQUARE FOOT 1.( 0.`. 0 L-1 SEmple Remolded at 90� of Maximum Density Sample Run at In—Place Density DIRECT SHEAR DATA Sample /angle of Internal Friction Cohesion • (6 @ 20') 23.4° 33 psf (6 @ 30') 38.5° 17 psf NORMtiL LOAD IN KIPS PER WARE FOOT 0 0.5 1.0 1.5 2.0 2.5 3.0 APPENDIX B Standard Grading Specificaitons B-1 STANDARD GRADING SPECIFICATIONS PROJECT: LA QUINTA LODGE CLIENT: LANDMARK LAND COMPANY 1. These Standard Grading Specifications have been prepared for the exclusive use of our client for specific application to referenced project in accordance with generally accepted soil and foundation engineering practices. No other warranty, expressed or implied, is made. 2. Buena Engineers, Inc., referred to as the soil engineer, should be retained to provide continuous soil engineering services during construction of the grading, excavation and foundation phases of the work. This is to observe compliance with the design concepts, specifications or recommendations and to allow design changes in the event that subsurface conditions differ from that anticipated prior to start of construction. 3. The presence of our field representative will be for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work of the contractor, his employees or agents. The contractor for this project should be so advised. The contractor should also be informed that neither the presence of our field representative nor the observation and testing by our firm shall excuse him in any way from defects discovered in his work. It is understood that our firm will not be responsible for job or site safety on this project. Job and site safety will be the sole responsibility of the contractor. 4. If the contractor encounters subsurface conditions at the site that (a) are materially different from those indicated in the contract plans or in specifications, or (b) could not have been reasonably anticipated as inherent in the work of the character provided in the contract, the contractor shall immediately notify the owner verbally and in writing within 24 hours. This notification shall be a condition precedent before any negotiations for "changed or differing site conditions" can proceed. If the owner determines that B-2 conditions do materially so differ and cause an increase or decrease in. the contractor's cost of, or the time required for, performance of any part of the work under this contract, then negotiations shall commence between owner and contractor to provide equitable adjustment to owner or contractor resulting therefrom. 5. Whenever the words "supervision", "inspection", or "control' appear they shall mean periodic observation of the workand the taking of soil tests as deemed necessary by the soil engineer for substantial ' compliance with plans, specifications and design concepts. 6. These: specifications shall be integrated with the Soil Engineering Report of which they are a part. Should conflicting statements be found between these standard specifications and the itemized recommendations contained in the main body of the soil report, the latter shall govern. 7. These specifications shall consist of clearing and grubbing, preparation of land to be filled, filling of the land, spreading, compaction and control of the fill, and subsidiary work necessary to complete the grading of the filled areas to conform with the lines, grades and slopes as shown on the accepted plans. 8. The standard test used to define minimum densities of compaction work shall be the ASTM Test Procedure D 1557. Densities shall be expressed as a relative compaction in terms of the maximum density obtained in the laboratory by the foregoing standard procedure. 9. Field density tests will be performed by the soil engineer during grading operations. At least one (1) test shall be made for each five hundred (500) cubic yards or fraction thereof placed with a minimum of two (2) tests per layer in isolated areas. Where sheepsfoot rollers are used, the soil may be disturbed to a depth of several inches. Density tests shall be taken in compacted material below the disturbed surface. When these tests indicate that the density of any layer of fill or portion thereof is below the required density, the particular layer or portion shall be reworked until the required density has been obtained. r. �i ,-i� � r�i (' iii .-.- r. •' B-3 10. Earth -moving and working operations shall be controlled to prevent water from running into excavated areas. Excess water shall be promptly removed and the site kept dry. Fill material shall not be placed, spread or rolled during unfavorable weather conditions. When the work is interrupted by heavy rain, fill operations shall not be resumed until field tests by the soil engineer indicate that the moisture content and density of the fill are as previously specified. 11. Compaction shall be by sheepsfoot rollers, vibrating sheepsfoot rollers, multiple - wheel pneumatic -tired rollers or other types of acceptable compacting rollers. Rollers shall be of such design that they will be able to compact the fill to the specified density. Rolling shall be accomplished while the fill material is within the specified. moisture content range. Rolling of each layer shall be continuous over its entire area and the roller shall make sufficient trips to insure that the required density has been obtained. 12. Existing structures, foundations, trash, debris, loose fill, trees (not included in landscaping), roots, tree remains and other rubbish shall be removed, piled or burned or otherwise disposed of so as .to leave the areas that have been disturbed with a neat and finished appearance free from debris. No burning shall be permitted in the area to be filled. 13. When fill material includes rock, large rocks will not be allowed to nest and voids must be carefully filled with small stones or earth and properly compacted. Rock larger than six (6) inches in diameter will not be permitted in the compacted fill without review as to location by the soil engineer. 14. Organic matter shall be removed from the surface upon which the fill, foundations or pavement sections are to be placed. The surface shall then be plowed or scarified to a depth of at least eight (8) inches and until the surface is free from ruts, hummocks or other uneven features which would tend to prevent uniform compaction by the equipment to be used. Specific recommendations pertaining to stripping and minimum depth of recompaction of native soils are presented in the main body of the soil report. B-4 15. Native soil free from organic material and other deleterious material may be used as compacted fill; however, during grading operations the soil engineer will re-examine the native soils for organic content. 16. Imported material should be tested and reviewed by the soil engineer before being brought to the site. The materials used shall be free from organic matter and other deleterious material. 17. Where fills are made on hillsides or exposed slope areas, greater than 10%, horizontal benches shall be cut into firm undisturbed natural ground to provide a horizontal base so that each layer is placed and compacted on a horizontal plane. The initial bench at the toe of the fill shall be at least 10 feet in width on firm, undistubed natural ground at the elevation of the toe stake placed at the natural angle of repose or design slope. The width and frequency of succeeding benches will vary with the soil conditions and the steepness of slope. 18. The selected fill material shall be placed in layers which, when compacted, shall not exceed six (6) inches in thickness. Layers shall be spread evenly and shall be thoroughly blade -mixed during spreading. After each layer has been placed, mixed and spread evenly, it shall be thoroughly compacted to a relative compaction of not less than ninety percent (90%). The fill operation shall be continued in six (6) inch compacted layers, as specified above, until the fill has been brought to the finished slopes and graded as shown on the accepted plans. 19. When the moisture content of the fill material is not sufficient to achieve required compaction, water shall be added until the soils attain a moisture content so that thorough bonding is achieved during the compacting process. When the moisture content of the fill material is excessive, the fill material shall be aerated by blading or other satisfactory methods until the moisture content is reduced to an acceptable content to achieve proper compaction. 20. Existing septic tanks and other underground storage tanks must be removed from the site prior to commencement of building, grading or fill operations. Underground tanks, including connecting drain fields and other lines, must be totally removed and the resulting depressions properly reconstructed and filled. Depressions left from tree removal shall also be properly filled and compacted. . , . i 1 • , , ` B -S 21. The methods for removal of subsurface irrigation and utility lines will depend on the depth and location of the line. One of the following methods may be used: 1) Remove the pipe and compact the soil in the trench according to the applicable portions of these grading recommendations, 2) The pipe shall be crushed in the trench. The trench shall then be filled, compacted according to The applicable portions of these grading specifications, 3) Cap the ends of the line with concrete to mitigate entrance of water. The length of the cap shall not be less than five (S) feet. The concrete mix shall have a minimum shrinkage. 22. Abandoned water wells on the site shall be capped according to the requirements of the appropriate regulatory agency. The strength of the cap shall be at least equal'. to the adjacent soils. The final elevation of the top of the well casing must be a minimum of thirty-six (36) inches below adjacent grade prior to grading or fill operations. Structure foundations should not be placed over the capped well. APPENDIX C Site Plan Log of Borings Trench Logs TNC f R04ARD 41B f�CP,E DEVELOP;-,-,'- NT L,4Ni.,N-1 P,KK LAN I-�-= LA OUi►JTA , Ch I BUENA ENGINEERS, INC. DATE 1-31-86 LOG OF BORING for La Quinta_.Lodge BORING NO. 1 Job No.B-16006-P1 Report No. 86-2-271 LOCATIONPer Plan Qi io 0 o hU a� o 3 o m DESCRIPTION " _ 3 -- �+ w C L U aC, u V1 L o v a. >. �-' V) C o (U ? DATE 1-31-86 LOG OF BORING for La Quinta Lodge BORING NO.2 Job No B -16006-P1 Report No.8672-271 LOCATION Per Plan s n a 6 o 0 >,o V 0 Um �- y 3 O DESCRIPTION •• �,� "c�U 5 6 °- v v H U o0 GL F- o v) C o v *' ? M v ro E U 00 0� U CL REMARKS AND ANALYSIS 0 42 Al: Tan very silty very fine sand 93.2. 3.8 SM 82 Terminated Drilling @ 16. ' 24 27 16 A3: Tan slightly silty very fine to fine sand A3: Light grey to tan slightly silty very fine to fine sand A3: Light grey to tan slightly silty very fine to fine sand 102.1 96.3 94.3 4.0 4.1 4.6 SP SP SP 91 86 84 5 10 15- 23 Al: Light grey brown very silty very fine 'sand 81.4 25.8 SM 72 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual No Free Water Encountered s r-i,'r(' n DATE 1-31-86 LOG OF BORING for La Quinta Lodge BORING NO.3 Job No.B-16006-P1 . Report No.86-2-271 LOCATION Per Plan c 0 «' X o H 3 v v 4: a v REMARKS AND ANALYSIS a E 3 DESCRIPTION ._r ro E` V >, p N o m �,;, � Q n c u CU a. � .. �n � 0 (U a 0 ... 17 A3: Greyish tan very silt 96.5 3.6 SP 86 "• very fine to fine sanc. 18 A3: Greyish tan very silt 92.7 3.8 SP 82 Trace roots 5 very fine to fine san 12 A3: Greyish tan very silt 92.6 3.2 SP 82 very f ine to fine san ' 10 14 B1: Light brown slightly clayey very fine sand silt 83.2 38.7 MH 71 Interbedded silts and 15 (SM ML S L 28 20 16 B1: Light brown slightly 86.2 36.4 MH 74 clayey very fine sandy silt Interbedded silts and 25 60 Al: Greyish tan very 9,3.8 10.3 SM 83 30 silty very fine sand Interbedded brown slight- ML/ 35 ly clayey very fine sand silt and silty very fine SM' sand 40 21 B3: Grey to rust brown 86.0 36.8 ML -- gilt TerminatedDrilling @ 41. NOTE: The stratification No Free Nater Encountered lines indicate the approx imate boundaries between 45 soil types and the trans- ition may be gradual Al: Light grey very silty very fine sand DATE 2-3-86 LOG.OF BORING for La Quinta Lodge BORING NO. 4 Job No.B-16006-P1 Report No.86-2-271 LOCATION Per Plan C 0 r o y v REMARKS AND ANALYSIS v E o o DESCRIPTION ..3,w �" ro E io Ln m ��a °� �a ° � a)ov �Ua 0 10 A2: Grey very silty very 85.9 34.0 SM -- Trace roots fine sand 18 A3: Grey very fine to 84.4 12.0 SP 75 fine sand 5 17 A2: Grey very silty very 97.1 6.2 SM fine sand Interbeddded sands and SM/ silty sands SP 19 A2: Light grey brown silty 85.3 19.5 SM -- Trace roots very fine sand 15 20 Al/A2: Light grey brown 85.5 -11.5 SM -- }h, s ty re me GsnAg�itgy Trace roots 20 24 A2/ Light grey brown 93.3 29.7 SM/ -- very silty very fine sand SM6 over brown silty very fin ML sand and silt 25 30 30 A2: Light grey brown 96.7 23.2 SM -- silty very fine sand 35 A2/A3: Light greyish green slightly silty very 40 30106.5 fine to fine sand over br 9.9 SMS SP 95 Disturbed sample own veru Terminated Drilling @ 41. NOTE: No Free Water Encountered The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual DATE 2-3-86 LOG OF BORING for La Quinta Lodge BORING NO, 5 Job NO -B -16006 -PI Report No. 86-2-271 LOCATION Per Plan C O ..� o ►- C 0 > ? ( v REMARKS AND ANALYSIS c. E ` 3 DESCRIPTION .. �,;; L. �' b CL E ` 0 �, V) O O m c C U D° o OJ °. 0 �n v o GJ C U a 0 L�Hl t Tan silty very fine sand SM 28 B1/A2: Tan very fine sand 80.1. 9.4 MH/ 69 silt over silty very fine SM sand 18 A3: Tan very fine to fine 94.1 4.2 SP 84 sand 5 16 Bl: Light greenish brown 115.6 4.2 MH 99 very fine sandy silt .. A3/133; Light grey brown 10 14 very fine to fine sand 91.4 27.4 SP/ 81 over light brown silt ML B1: Light green brown MH very fine sandy silt 15 21 B1/A2: Light green brown 94.0 27.4 MH/ 81 Decomposed roots very fine sandy silt over SSI silty very fine sand 20 - • 32 A3: Tan very fine to fine sand 91.5 7.1 SP 81 Terminated Drilling @ 21. NOTE: The stratification lines No Free Water Encountered indicate the approximate boundaries between soil types and the transition may be gradual DATE 2-3-86 LOG OF BORING for La Quinta Lodge BORING NO. 6 Job No.B-16006-P1 Report No.86-2-271 LOCATION Per Plan L a v 0 o >10 V) m y 3 0 DESCRIPTION -fine " 3 w c�U �O a L ov �4 o V c 0 a b i vov �Ua REMARKS AND ANALYSIS 19 A2/A3: Grey tan very silt very fine sand over very to_ftup 78_qnnd.8 8.9 SM/ SP 70 Terminated Drilling @ 21. 17 A2/A1: see below 92.6 13.9 SM 82 5 20 A3: Light brown very fine to fine sand 89.1 4.4 SP 79 10 AM 17 A3/.A2; (see below) 102.4 12.2 SEA 91 11111 B1: Light brown silty very fine sand ML .15-:'o 25 A3/A2: (see below) 88.4 12-2 SP/ SM 7Q 18 30 A2: Light grey brown silty very fine sand A2: Light brown silty very fine sand 96.8 95.9 17.5 17 SM SM I -- 20 25- 30 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual A2/A1; Blue grey silty ve fine sand over light browi very silty very fine sand A3/A2: Light brown very f to fine sand over very silty very fine sand y ne No Free Water Encountered DATE 2-3-86 LOG OF BORING for Lp Quinta Lodge BORING NO, 7 Job No.B-16006-P1 Report No, 86-2-271 LOCATION Per Plan s a V in o .0` >'0 v: y 3 0 m DESCRIPTION - .. 3 „� c�U �D a v L oar �C �' 0 C 0 ? a v b a` aov a:Ua REMARKS AND ANALYSIS 0 , ;; 28 20 20 33 A3: Tan very fine to fine sand A3: Tan very fine to fine sand A3:'Tan very fine to fine sand A3: Tan very fine to med- ium sand over very fine to fine sand 93.9 100.4 98.8 102.1 3.1 3.1 4.3 4,1 SP SP SP SP 84 89 88 91 , Terminated Drilling @ 16. 5 10 25ypry Al: Light brown very silt fine sand 86.0 11.2 SM 76 L5 - L I NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual No Free Water Encountered —•- DATE 2-4-86 LOG OF BORING for La Quinta Lodge BORING NO, 8 Job NO.B-16006-P1 Report No.86-2-271 LOCATION Per Plan s n o 0 o E � vi O y o sn DESCRIPTION .. �w C L U 5 a a. v �_ O O :E a 0 C 0 _' b y _ro y 0 0 C2 U n REMARKS AND ANALYSIS 24 A2/A3: Light brown very silty very fine sand over grey brown silt' 90.5 28.4 SM/ -- rooting Terminated Drilling @ 16' 18 A2: Grey brown silty very fine sand 81.7 11.1 SM -- •.• 17 20 A2/Al: Grey brown very silty very fine sand over fine sand Interbedded silty sands and sands A3: Light brown very fine to fine sand 94.6 94.0 22.5 -14.0 SM SP 83 84 ,.. 10 25 B1/A2: Light brown very fine sandy silt with int- erbeds of very silty very fine sand 85.7. 31.2 ML/ SM 73 15 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual No Free Water Encountered DATE 2-4-86 LOG OF BORING for La Quinta Lodge BORING NO. 9 Job No.B-16006-P1 . Report No. 86-2-271 LOCATION Per Plan r o o E o v, U y o co DESCRIPTION �_ � c L V :DD a _ � H L O O in' _ v) c o _ ? n °c' ro E Gl O O orUCv ' REMARKS AND ANALYSIS 0 ,,,. ,,. 25 18 14 A3: Tan very fine to fine sand A3: Tan very fine to fine sand A3: Tan very fine to fine sand 91.7 81.5 85.6 5.7 7.1 7.3 SP SP SP 82 73 76 Terminated Drillin @ 16. 5 20 B3/A2: Light brown silt with interbeds of silty very fine sand 96.0 23.2 _ ML/ SM 10 15A2/A3: k::34silty Grey brown very vr fine sand over tan very,ne to fine san 91.0 16.0 SM/ SP 81 NOTE:- The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual No Free Water Encountered r' 1-.,, F' rl DATE 2-3-86 LOG OF BORING for La Quinta Lodge BORING NO. 10 Job No.B-16006-P1 Report No.86-2-271 LOCATION Per Plan n v C] 0 o 0` Vn o 3 o m DESCRIPTION 3 ,-. �,w c�U -j D a• v L. ov � n' � F- - vii o '_ . c. b E a�0V GY. U n REMARKS AND ANALYSIS „• . ••" 28 27 30 A3: Tan very fine to fine sand A3: Tan very fine to fine sand A3: Tan very fine to fine sand 89.7 ---- 99.3 4.9 --- 2.6 SP SP SP 80 88 Terminated Drilling @ 16.: 26 A2: Light brown slightly silty very fine sand 83.7 12.4 SM -- 10 ' ' ' 29 A3: Tan very fine to fine sand 90.4 4.7 SP 80 15 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual No Free Water Encountered DATE 2-4-86 LOG OF BORING f or La Quinte Lodge BORING NO. 11 Job No. B -16006-P1 Report N086-2-271 LOCATION Per Plan «. v 0 o E vii v O 3 O m DESCRIPTION " �_ T^ r- �. U 5a a v �_ C O v i°• v F" �' V) C 0 �. Mv ,v E v 0 0 ORU°..- REMARKS AND ANALYSIS 0 67 30 26 40 A2: Tan very silty very fine sand A2: Tan very silty very fine sand A2: Tan very silty very fine sand A2: Tan very silty very fine sand -- 88.4 -- 87.2 -- 2.7 -- 6.4 SM SM SM SM -- -- ' Trace roots erminated Drillin @ 31.0 5 10- 15 30 A3: Tan very fine to fine 89.5 5.6 SP 80 B1/B3:Light brown very fi silt and silt a MH/ M1, 2 _sandy A2 (see below) cm 41 A2/A3-L' ht b own sil ver fins to fine sandy over whitish tan very fin to ine san 94.7 2.8 SM/ SP 84 35 A2: Light brou-n very silt very fine sand 92.0 28.9 ISM-- 25 30 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual lo Free Water Encountered DATE 2-4-86 LOG OF BORING for Lg Quinta Lodge BORING NO. 12 Job No.B-16006-P Report No.86-2-271 LOCATION Per Plan r i 0 o E V) oo` c ca DESCRIPTION 3 41 �,�, �� n � 0 0 ` �a F � •o c 0 ? a v b E ` —000 REMARKS AND ANALYSIS 20 21 33 A2: Tan silty very fine sand A2: Tan silty very fine Sand A2: Tan silty very fine. sand -- -- -- 1.2 1.4 -- SM SM SM -- -- -- , Terminated Drilling @ 16.E 5 40 A3/B'1: Tan very fine to fine sand inter- bedded with tan very fine sandy silt 99.1 1.2 SP/ MH 88 34 A2: Tan silty very fine sand -- 3.3 SM -- 5 NOTE: The stratification lines indicate the approximate boundaries between soil types and'the transition may be gradual No Free Water Encountered! [—ic+ic 0 DATE 2-5-86 Trench Log For La Quinta Lodge Trench # 1 Job No.B-16006-P1 Report No. 86-2-271 LOCATION Per Plan .. s a-0 0 o Eo V) 0 y 3 o m DESCRIPTION � �w c..0 s p a M y � oar : a �' V) C o ? M C b E a,ov Cy.U CL REMARKS AND ANALYSIS N N Al: Medium brown silty fine sand 98.8 87,2 12.1 24.2 SM 87. 77 Terminated Trenching @ 13 A3: Light brown fine sand 97.7 8.8 SP 87 5 10 A3/B2: Light brown fine sand SP/ Mg NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered 15 DATE 2-5-86 Trench Log For La` Quinta Lodge Trench lit Job No.B-16006-P1 Report No.86-2-271 LOCATION Per Plan `r 0. v 10 0 o E �n �? o Ucfl 3 o DESCRIPTION 3 w c U :D 0 a. v i o v .2 CL F' V) C o c ro E V 0 V W U CL REMARKS AND ANALYSIS N N N Al: Light brown silty fine sand Al: Light brown silty fine sand Al 97.3 97.6 98.2 1.0 2.8 3.2 SM SM SM 86 86 86 Terminated Trenching @ 13. 5 Light.brown slightly clayey very fine to medium fine sandy silt 10 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered A 15 DATE 2-5-86 Trench Log For La Quinta Lodge Trench 413 Job No.B-16006-P1 Report No. 86-2-271 LOCATION Per Plan .-. .. n. V io 0 o E E V)U a? o 3 o co DESCRIPTION .. 3 'c ` U 4) N L o v a v � C. �' vo) c o �,.. ' roa ac, ro v o v ce U It REMARKS AND ANALYSIS N N N Al: Light brown very silty very fine sand Al; .Light brown very silt very fine sand Al: i -p t brown silty fin 95.1 89.8 91.1 2.8 6.7 7.9 SM SM SM 84 79 80 , Terminated Trenching @ 10' 5 A2: Brown slightly silty very fine to fine sand SM 10 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered M�--- [-laic 13 DATE 2-5-86 Trench Log For La Quinta Lodge Trench #4 Job No.B-16006-P1 Report No. 86-2-271 LOCATION Per Plan ,-. X v 0 o E o y o DESCRIPTION 3.w v ~ V)° c o ? n ac, b E L �Ua REMARKS AND ANALYSIS N N N Al: Light brown very. silty very fine sand Al: Tan silty very fine to fine sand A1:.Light tan slightly silty'very fine to 93.5 85.9 89.3 4.7 3.7 4.2 SM SM SM 82 76 79 Roots to 4.0' Terminated Trenching @ 10 5 A2: Brown slightly silty very fine to fine sand SM 10 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered Plate R DATE 2-5-86 Trench Log For La Quinta Lodge Trench X15 Job No.B-16006-P1 Report No. 86-2-271 LOCATION Per Plan a a, im ° Eo , V) a? U 3 o m DESCRIPTION .� 3 w C`U J0 ° o v 20- o V) c o ? c vo w C 4 U • REMARKS AND ANALYSIS 0 N Al: Light brown silty very fine sand 93.1 8.2 SM 82 Terminated Trenching @ 11 N N A3: Light brown slightly silty very fine to medium fine sand A3::Light.brown slightly silty very fine to medium fine sand 88.2 96.0 10.2 7.0 SP SP 79 85 5 10 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered 1- la f (- n DATE 2-5-86 Trench Log For La Quinta Lodge Trench V6 Job No.B-16006-P1 Report No. 86-2-271 LOCATION Per Plan a OO D 0 o vii 3 O c3 DESCRIPTION , 3 w c&_ U Z) 13 O N ac,n �_ � O O fin' O 0. �" vci c O y a+ Z v ro O v aUa REMARKS AND ANALYSIS N N Al: Dark brown very silty very fine sand A1, fanevery msilt err 86.5 92.9 9.5 4.7 SM SM 76 82 , Terminated Trenchin 0 ' NJ A2: Tan slightly silty v 88.5 7.3 SM -- 5 NOTE• The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered DATE 2-5-86 Trench Log For La Quinta Lodge Trench #7 Job NO.B-16006-P1 Report No. 86-2-271 LOCATION Per Plan s a d! 0 o E V) v O o c0 DESCRIPTION 3 .. �W c L U �� a _ M � �_ O O �M v°) c O _ ? c. ( (o E y 0 0 aUn. REMARKS AND ANALYSIS N N Al: Light brown silty very fine sand Al: Light brown silty very fine sand 93.8 90.6 0.5 0.8 SM SM 83 80 ' erminated Trenching @ 6. 5 — NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test o Free Water Encountered ni n DATE 2-5-86 Trench Log' For La Quinta Lodge Trench X18 Job No.B-16006-P1 Report No.86-2-271 LOCATION Per Plan s a v D o �o V) �? 3 O m DESCRIPTION " 4, 3, cru :DD .° v ov i s f- o V) C 0 ' ro a vov oC U a REMARKS AND ANALYSIS 0 N Al: Light brown very silt fine sand 97.8 2.2 SM 86 ' Terminated Trenching @ 5. N N A2: Light brown silty fine sand A2; Light brown silty fine sand 89.5 83.2 7.3 2.6 SM SM -- 5 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered r1r1W n DATE 2-5-86 Trench Log For La Quinta Lodge Trench 019' Job No.B-16006-P1 Report No.86-2-271 LOCATION Per Plan Qo 0 E vii c o co DESCRIPTION .. �„� Ut] Y ` 2a c, �' V) C o ? r Trench Log Job No.B-16006-P1 For Report No.86-2- 271 La Quinta Lodge DATE 2-5-86 Trench 1110 LOCATION Per Plan r 1 V o 0 >0 V). :.' 0 o DESCRIPTION �� "c u v L 0 a) F• o C 0 ? b b L a� 0 0 REMARKS AND ANALYSIS 0 Al: Light brown very silty fine sand 90.6 21.7 SM 80 erminated Trenching @ 5. N A2: Light brown silty fine sand A2; Light brown silty :fine sand 93.2 88.6 25.9 12.1 SM SM -- -- 5 NOTE: The stratification lines indicate the approximate boundaries between soil types and the transition may be gradual N = Nuclear Density Test No Free Water Encountered Trench Log Job N o.B-16006-P1 For Report No.86-2-271 La Quinta Lodge DATE 2-5-86 Trench 1111 LOCATION Per Plan v r a 0 o E vi o W y o m DESCRIPTION • ..3,w c` U Z)6 n Q� H v ` o v 2 Q, F' o C o u N ?