13523 (SFD) Revision 1 Title 24TITLE 24 REPORT FOR:
Plan 1
Stephen Jones Project
La Quinta, Ca.
PROJECT DESIGNER:
} Stephen Jones, Design & Construction
Post Office Drawer 4656
Palm Desert, Ca. 92261
346-3366
REPORT PREPARED BY:
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST CHARLES PLACE
PALM DESERT, CA, 92260
( 619) 346-0855
Job Number:
Date: 6/2/1994
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the
Residential and Nonresidential. Building Energy Efficiency Standards.
This program developed by Gabel Dodd Associates (510) 428-0803.
Table Of Contents for Title 24 Report
------------------------------------
r
CoverPage........................................................... 1
`fable of Contents ................................................... 2
Form CF -1R Certificate of Compliance: Residential 3
Form MF -1R Mandatory Measures Checklist: Residential ................ b
Form C -2R Computer Method Summary ........... 7
HVAC Zone & Space Loads Summary ..................................... 10
---------------------------------------------------------------------------
Project Name: Plan 1 ;Date: 6/2/1994
Address: Stephen Jones Project
La Quinta, Ca. ;Building Permit No
Designer: Stephen Jones, Design & Construction ;Checked by / Date
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area.-
Building
rea:Building Type:
Building Front Orientation:
Number of Dwelling Units:
Floor Construction Type:
BUILDING SHELL INSULATION
Component
-----------------------
R-21 Wall (W.21.2x6.16)
R-38 Roof( R .38 .2x 14 .16 )
Slab Perimeter w/R-O.O
Slab Perimeter w/R-0.0"
FENESTRATION
Orient. Area
Lel" t
( N )
33.0
Bac k
( E )
108.0
Bac k
( E )
53.0
Right
( S )
4.5
Front
( W )
72.0
Skylight
15.8
U -Val Type
0.87 Double
0.87 Double
0.87 Double
0.72 Double
0.87 Double
0.52 Double
COMPLY 24 version 4.11
15
1631 sqf t
Single Fam Det
270 deg ( W )
1
Slab on Grade
U -Value Location/Comments
------- ------------------------------------
0.059 Plan 1
0.028 Plan 1
0.900 Plan 1
0.720 Plan 1
Shading Devices Frame
Interior Exterior OH SF Type
--------------- --------------- -- -- -----
Light Blind Standard Bug Scr N N Metal
Light Blind Standard Bug Scr N N Metal
Light Blind Standard Bug Scr Y 'N Metai
Light Blind none N- N Metal
Light Blind Standard Bug Scr Y N Metal
none none N N Metal
THERMAL MASS Area Thick
Type Covering (sf) (in) Location/Description
----------------------------- ----- ----- ------------------------------
Concrete, Heavyweight Exposed 655 3.50 Slab on Grade
Concrete, Heavyweight Covered 958 3.50 Slab on Grade
--------_ ---_ -_ -_ --------------------------------7-------------------
PToject Name: Plan 1 ;Date 6/2/1994
Documentation: BREEZE ATR CONDITIONING
;COMPLY 24 User 3665
---------------------------------------------------------------------------
HVAC SYSTEMS Minimum Distrib,Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
------------------------------------- ---- ------ ------------ -----------
PackHtPump 6.850 HSPF Ducts in Attic 8.0 SetBck Plan 1
PackHtPump 11.050 SEER Ducts in Attic 8.0 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insui
System Name Distribution Type Type Sys Factor (gal) R -Val
----------------------- ------------------ ------- --- ------ ----- -----
AO SMITH FSG -50 Standard StorGas 1 0.53 50.0 21.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- ---- ----- ----- ----- -----
AO SMITH FSG -50 DomesticHW 0.780 37000 0.035 0.0 0
SPECIAL FEATURES/REMARKS
N
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title 24, Parts 1 & 6 of the Califor-
nia Code of Regulations, and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
(Per Business & Professions Code)
Stephen Jones, Design & Construction
Post Office Drawer 4656
Palm Desert, Ca. 92261
346-3366 Lic #:-
(signature)
:
(signature)
ENFORCEMENT AGENCY
Name:
Title:
Agency:
Telephone:
( date )
DOCUMENTATION AUTHOR
Tim Scott
BREEZE AIR CONDITIONING
75-145 ST CHARLES PLACE
PALM DESERT, CA 92260
( 619 1 346-0855
(signature) (date)
(signature/stamp) (date)
---------------------------------------------------------------------------
Nroject Name: Plan 1 ;Date: 6/2/1994
Documentation: BREEZE ATR CONDITIONING �
;COMPLY 24 User 3665
------------------------------------------ --------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
o Sec. 150(a): Minimum R-19 ceiling insulation.
o Sec. 150(b): Loose fill insulation manufacturers
labeled R -Value.
o Sec. 150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls). *
o Sec. 150(d): Minimum R-13 raised floor insulation in tramed
floors; Minimum R-8 in concrete raised floors. *
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
Enforcement
o Sec. 118: Insulation specified or installed meets California
Energy Commission quality standards. Indicate Type & form.
o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label w/certitied U -Value
c. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
o Sec. 150(8): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 150(t): Special infiltration barrier installed to
comply with Sec. 151 meets Commission quality standards.
o Sec. 150(e): Installation of Fireplaces, Decorative Gas
Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
-------_ -_ ---------------------------------------------------------------
Project'Name: Plan 1 ;Date: 6/2/1994
Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665
---------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads
and faucets certified by the Commission.
o Sec. 150(i'): Setback thermostat on all applicable
heating systems.
o Sec. 150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (eg unfired storage tanks or
backup solar hot water tanks) have insulation blanket
(R-12 or greater) or combined interior/exterior insulation
(R-16 or greater).
2. First 5 feet of pipes closest to water heater tank,
non -recirculation systems, insulated (R-4 or greater.
3. All buried or exposed piping insulated in recirculation
sections of hot water system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between heating source and indirect hot
water tank.
o Sec. 150 m) Ducts and Fans *
1. Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and 1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers.
o Sec. 114:Pool and Spa Heating,Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is instai'led with:
a. At least 36" pipe between filter and heater for future
solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 115: Gas-fired central furnace, pool heater, spa heater
or household cooking appliance have no continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec. 150�k): Lighting - 40 lumens/watt or greater for
general lighting in kitchens and rooms with water closets;
and recessed ceiling fixtures IC (insulation cover) approved.
---_ -- --- - - - --------------------------------------------------------
PT oject Name: Plan 1
;Date:
6/2/1994
Documentation: BREEZE AIR CONDITIONING
---------------------------------------------------------------------------
;COMPLY
24 User 3665
Standard
Proposed
Compliance
Source Energy Use (KBtu/sf-yr)
------------------------------
Design
--------
Design
--------
Margin
Space Heating
4.59
3.99
----------
0.61
Space Cooling
31.51
31.95
-0.44
Domestic Hot Water
13.43
13.18
0.25
TOTALS
49.53
49.11
0.42
*** BUILDING
COMPLIES ***
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
COMPLY 24 version 4.11
15
1631 sgft
Single Fam Det
270 deg ( W )
1
1
Slab on Grade
14679 cuf t
1613 sqf t
1613 sqf t
BUILDING ZONE INFORMAT'I'ON
Floor # of Vent
Zone Name Area Volume Units Zone Type TStat Type Hgt Area
----------------------- ----- ------ -------------------------- --- ----
Plan 1 1631 14679 1.00 Conditioned Setback 2 n/a
OPAQUE SURFACES Act
Type Area U -Val Azm.
---- ---- ----- ---
ZONE:NAME = Plan 1
Wall 355 0.059 180
Wail 368 0.059 270
Wall 279 0.059 90
Wall 349 0.059 0
Root 1597 0.028 0,
Solar
Tilt Gains Form 3 Reference Location/Comments
---- ----- ----------------------- --------------------
90 Yes R-21 Wall ( W .21 .2x6.16) Plan 1
90 Yes R-21 Wall ( W .21 .2x6 .16) Plan 1
90 Yes R-21 Wall ( W .21 .2x6 .16) Plan 1
90 Yes R-21 Wall ( W .21 .2x6 .16) Plan 1
22 Yes R-38 Roof(R.38.2xl4.16) Plan 1
---------------------------------------------------------------------------
K oject Mame:
Plan 1
;Date:
6/2/1994
Documentation:
---------------------------------------------------------------------------
BREEZE AIR CONDITIONING
;COMPLY
24 User 3665
PERIMETER LOSSES
Type Length
--------- ------
ZONE NAME = Plan 1
Exposed 99.0
Covered 105.0
FENESTRATION SURFACES
# Type
`LONE NAME = Plan
I Wow Right ( S )
2 Wow Right ( S )
3 Wow Front ( W )
4 Wow Back ( E )
5 Wow back ( E )
6 Wow Back ( E )
7 Wow Back ( E )
8 Wow Left ( N )
9 Wow Left ( N )
10 Wow Lent ( N )
11 Sky Lett ( N )
F2 Insulation
Factor R -Val Depth Location/Comments
------ ----- ----- --------- --------------
0.90 0.0 0 in Plan 1
'0.72 0.0 0 in Plan 1
Area Frame Div U -Val
----- ----- --- -----
1
SC
Act Glass
Azm Tilt Only Location/Comments
--- ---- ----- ---------------------
2.3
Metal
No
0.72
180
90
0.88
Plan 1
2.3
Metal.
No
0.72
180
90
0.88
Plan 1
72.0
Metal
No
0.87
270
90
0.88
Plan 1
72.0
Metal
No
0.87
90
90
0.88
Plan 1
18.0
Metal
No
0.87
90
90
0.88
Plan 1
18.0
Metal
No
0.87
90
90
0.88
Plan 1
53.0
Metal
No
0.87
90
90
0.88
Plan 1
18.0
Metal
No
0.87
0
90
0.88
Plan 1
3.0
Metal
No
0.87
0
90
0.88
Plan 1
12.0
Metal
No
0.87
0
90
0.88
Plan 1
15.8
Metal
No
0.52
0
0
0.55
Plan 1
INTERIOR & EXTERIOR SHADING
# Type Interior Shade Type
-- ---- -----------------------
1 Wow, Light Blind
2 Wow Light Blind
3 Wow Light Blind
4 Wow Light Blind
5 Wow Light Blind
6 Wow Light Blind
7 Wow Light Blind
8 Wow Light Blind
9 Wow Light Blind
10 Wow Light Blind
11 Sky None
SC
Exterior
Shade Type
SC
0.58
None
1.00
0.58
None
1.00
0.58
Standard
Bug
Screen
0.87
0.58
Standard
Bug
Screen
0.87
0.58
Standard
Bug
Screen
0.87
0.58
Standard
Bug
Screen
0.87'
0.58
Standard
Bug
Screen
0.87
0.58
Standard
Bug
Screen
0.87
0.58
Standard
Bug
Screen
0.87
0.58
Standard
Bug
Screen
0.87
1.00
None
1.00
---------- ---------------------------------------------------------------
Project Name=
Plan 1
;Date:
6/2/1994
Documentation:
----------------------------------------------------------------------------
BREEZE AIR CONDITIONING
;COMPLY
24 User 3665
OVERHANGS/SIDE FINS
--Window--
# Type Ht Wd
_- ---_ _--- ___-
3 Wdw 8.0 9.0
7 Wdw 6.7 8.0
----- overhang -----_
Len Ht LExt RExt
---- ---- ---- ----
6.0 0.1 6.0 6.0
4.0 0.1 4.0 4.0
---Left Fin--- ---Right Fin --
Dist Len Ht Dist -Len Ht
--------- ---- ---_ __-- __--
THERMAL MASS Area Thick Heat Inside Location
Type ( sf) (in) Cap Cond Form 3 Reference R -Val . Comments
------------- ---- ----- ----- --------------------------- ------ --------
ZONE NAME = Plan 1
Exposed Slab 655 3.50 28 0.98 n/a 0
Covered Slab 958 3.50 28 0.98 n/a 2
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System type Efficiency and Location RVal Type Location/Comments
------------------------------------- ---- ------ -----------------------
PackHtPump 6.850 HSPF Ducts in Attic 8.0 SetBcK Plan 1
PacKHtWump 11.050 SEER Ducts in Attic 8.0 SetBck
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in- Energy Size insui
System Name Distribution Type Type Sys Factor (gal) R -Val
----------------------- ------------------ ------- --- ------ ----- --_--
AO SMITH FSG -50 Standard StorGas 1 0.53 50.0 21.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- _--- ----- ----- ----- -----
AO SMITH FSG -50 DomesticHW 0.780 37000 0.035 0.0 0
SPECIAL FEATURES/REMARKS
-- -------------------------
--------------------------------------------------------------
Aojec
wroject Name:
Plan
- ----------------------------------------
1
;Date:
------------
6/2/1994
.
Documentatio n
--------------------------------------------------------------------------
.BREEZE
AIR CONDITIONING
i
;COMPLY
24 User 3665
HVAC ZONE DESCRIPTION
HVAC Gone Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Fan Schedule:
Peak Load Method:
Relative Humidity:
SPACES 1N THIS ZONE PEAK
----------------------- ----
Plan 1 ( Jan 12am )
TOTAL SPACE LOAD
Duct Gains & Losses:
Ventilation ( 0 CFM)
Return Air Lighting Gain
TOTAL SYSTEM LOAD
SYSTEM OUTPUT AT DESIGN CONDITIONS
Plan 1
Lennox CHP20-b5i
1
Ali On Load Calcs
COINCIDENT
50
COOLING
HEATING PEAK SENSIBLE LATENT
------- ------------- ------
34394 (Aug 2pm) 34758 -3163
34394 34758 -3163
3439 3476
0 0 U
0
37833 38234 -3163
45351 45506 5558
NO0 The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no'safety factor, and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
J
---------------------------------------------------------------------------
Nroject Name: Plan.1 ;Date: 6/2/1994
Documentation: BREEZE ATR CONDITIONING ;COMPLY 24 User 3665
7 --------------------------------------------------------------------
Space Name : Plan 1
Design indoor Dry Bulb Temperature:
Design Outdoor Winter Dry Bulb Temperature:
Design l emperature Difference:
Conduction
R-21 Wail ( W .21 .2x6 .16 )
Double Clear Default(R )
Double Clear Default(R )
Double Clear Default(R )
Double Clear Default(R )
Double Clear Default(R )
Double White Trans
R-38 Root(R .38 :2x14 .16 )
Slab on Grade
Slab on Grade
Infiltration: 1.00 x 0.018 x
Heating AirFlow
u
72 F
31 F
41 F
34394 Btu/hr / L1.07 x 33 F DeltaT)j = 974 cfm
Area
------
U -Value
-------
TD
Btu/hr
1350.5
x
0.0592
x
----
41.0
------
- 3278
33.0
x
0.8700
x
41.0
= 1177
108.0
x
0.8700
x
41.0
- 3852
53.0
x
0.8700
x
41.0
= 1891
4.5
x
0.7200
x
41.0
- 133
72.0
x
0.8700
x
41.0
- 2568
15.8
x
0.5200
x
41.0
- 336
1597.2
x
0.0283
x
41.0
= 1856
Perim =
99.0
x
42
= 4158
Perim =
105.0
x
42
= 4410
1631 sf
x 9.0
ft
x 1.00 AC
x
41.0
= 10734
TOTAL
HOURLY
HEAT
LOSS FOR
SPACE
34394
34394 Btu/hr / L1.07 x 33 F DeltaT)j = 974 cfm
---------------------------------------------------------------------------
.Project Name:
Plan 1
Area
Heat Gain
;Date: 6/2/1994
Btu/hr
Documentation:
------------------------
BREEZE AIR CONDITIONING
--------------------------------------------------
;COMPLY
24 User
3665
Space Name:
Occupants
1.00 x
1631.0 x
225 /
Plan 1
- 1102
Design Indoor
Dry Bulb
Temperature:
x 1.00 AC
x-14.9
76 F
Design Outdoor
Summer Dry Bulb Temperature:
113 F
Design Temperature
Difference:
37 F
Conduction
-----------------------
Area
------
U -Value
DETD Btu/hr
R-21 Wall ( W .21
.2x6 .16 )
1350.5
-------
x 0.0592 x
---- ------
32.6 -
2607
Double Clean
Default(R)
33.0
x 0.8700 x
37.0 =
1062
Double Clear
Default(R)
108.0
x 0.8700 x
37.0 =
3477
trouble Clear
Default(R)
53.0
x 0.8700 x
37.0 =
1706
Double Clear
Default(R)
4.5
x 0.7200 x
37.0 =
120
Double Clear
Default(R)
72.0
x 0.8700 x
37.0 -
2318
Double White
Trans
15:8
x 0.5200 x
37.0 =
303
R-38 Roof(R.38.2x14.16)
1597.2
x 0.0283 x
53.0 =
2400
Intiltration:
1.00 x 0.018 x 1631
sf x 9.0 ft
x 1.00 AC x
37.0 =
9687
Shaded
Unshaded
Solar Gain
-----------------------
Orient.
---------
Area SGF
Area SGF
Sc
Double Clear
Default(R)
South
---- ---
L 0.0 x 15
---- ---
+ 2.3 x 32J
----
x 0.51 =
36
Double Clear
Default(R)
South
L 0.0 x 15
+ 2.3 x 32j
x 0.51 =
36
Double Clear
Default(R)
West
L 42.3 x 15
+ 29.7 x 73J
x 0.49 =
1373
Double Clear
Default(R)
East
0.0 x 15
+ .72 .0 x 73i
x 0.49 =
2575
Double Clear
Default(R)
East
L 0.0 x 15
+ 18.0 x 73,J
x 0.49 =
644
Double Clear
Default(R)
East
L 0.0 x 15
+ 18.0 x 73J
x 0.49 =
644
Double Clear
Default(R)
East
24.6 x'15
+ 28.4 x 731
x 0.49 =
1195
Double Clear
Default(R)
North
[ 0.0 x 15
+ 18.0 x 15.J
x 0.49 =
132
Double Clear
Default(R)
North
0.0 x 15
+ 3.0 x 15J
x 0.49.=
22
Double Clear
Default(R)
North
0.0 x 15.+
12.0 x 15J
x 0.49 =
88
Double White
Trans
Skylight
0.0 x 15
+ 15.8 x152)
x 0.50 =
1186
Internal Gain
--------------------
Op Frac.
-------- --------
Area
Heat Gain
Conv.
Lighting
1.00
------
x 1631.0
---------
x 0.200 x
-----
3.413 -
1113
Equipment
1.00
x 1631.0
x 0.100 x
3.413 =
557
Occupants
1.00
x 1631.0
x 225 /
333 -
1102
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 34758
Latent Gain
--------------------=--
Op Frac.
--------
Area
Heat Gain
Conv.
Btu/hr
Equipment-
1.00 x
------
1631.0 x
---------
0.000 x
-----
3.413
------
= 0
Occupants
1.00 x
1631.0 x
225 /
333
- 1102
Infiltration:
1.00 x 0.018 x 1631 sf
x 9.0 ft
x 1.00 AC
x-14.9
- -3912
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE -3163
Cooling AirFlow: 34758 Btu/hr / [1.07 x 21 F DeltaT)J = 1547 cfm