Loading...
11-1274 (RER) Revision 1i P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&t!t 4 4 4" Application Number: 11-00001274 Property Address: 54175 AVENIDA HERRERA APN: 774-213-019-8 -000000- Application description: REMODEL - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 40000 Applicant: „ ) n - y4rchiiect or Engineer: M14 ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves. thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). r I am exempt under Sec. , B.&P.C. for this reason Date: Z2, Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/22/13 Owner: RADI ROBERT/WANT QIMIN 54305 EISENHOWER DRIVEr�76��F LA QUINTA, CA 92253 2 2013Contractor: EHOwner A QUINTA ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that; in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwcomply with those provisions. Date: Z Z Applicant: WARNING: FAILURE TO SECURE WORKERS' COMP E ION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. I . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold Harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced Within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, 59d hereby authorize representatives of this county to enter upon the above-mentioned property f m ection e0toses. Date: Signature (Applicant or Agent): r It LQPEEMIT Application Number . . . . . 11-00001274 ------• Structure Information 176SF ADDITION W/REMODEL/VB/RES-3/CL-A ----- Other struct info . . . . . CODE EDITION 2010 ---------------------------------------------------------------------------- Permit . . . Additional desc . . Permit Fee . . . . Issue Date . . . Expiration Date . . BUILDING PERMIT 349.50 Plan Check Fee . 227.18 2/15/12 Valuation . . . . 40000 4/29/13 Qty Unit Charge Per Extension BASE FEE 252.00 15.00 ---------------------------------------------------------------------------- 6.5000 THOU BLDG 25,001-50,000 97.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 79.87 P1an.Check Fee 19.97 Issue Date . . . . 2/15/12 Valuation . . 0 Expiration Date 4/29/13 Qty Unit Charge Per Extension BASE FEE 15.00 176.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 3.52 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 103.00 ------------- -------------------------------------------------------------- .4500 EA ELEC DEVICE/FIXTURE >20 46.35 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 81.50, Plan Check Fee 20.38 Issue Date . . 2/15/12 Valuation . . . . 0 Expiration Date 4/29/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH APPL REP/ALT/ADD 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 3.00 6.5000 EA MECH VENT FAN 19.50 1.00 -------------------------------------------- 6.5000 EA MECH EXHAUST HOOD -------------------------------- 6.50 Permit. . . PLUMBING Additional.. desc . . Permit Fee . . . . 103.50 Issue Date . . 2/15/12 Plan Check Fee 25.88 Valuation . . 0 i Application Number . . . . . 11-00001274 Permit . . . . . PLUMBING Expiration Date . . 4/29/13 Qty Unit Charge Per Extension BASE FEE 15.00 11.00 6.0000 EA PLB FIXTURE 66.00 2.00 6.0000 EA PLB ROOF DRAIN 12.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA- PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 176SF MECHANICAL ROOM/STORAGE ADDITION WITH DECK AND REMODEL TO GARAGE, WORKSHOP AND RESIDENCE/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE ALTERATION TO THE EXISTING POOL OR REPLACEMENT OF MISSING EQUIPMENT, NOR DOES IT PERMIT THE WORKSHOP TO BE USED FOR SLEEPING PURPOSES, OR THE EXISTING UNPERMITTED FOUNDATION TO BE USED FOR NEW CONSTRUCTION. PUBLIC WORKS APPROVED LOT MERGER NUMBER: 2011-496 - RECORDED 12/16/2011 DOCUMENT NUMBER: 2011-0557074. CODE CASE NUMBER: 10-5433 [JM] 2010 CALIFORNIA BUILDING CODES. . January 31, 2012 3:50:47 PM AORTEGA REVISION 1: STRUCTURAL FOUNDATION ALTERATIONS - SEE NEW S.1 SHEET FOR SCOPE OF WORK. April 5, 2012 3:14:50 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 CHANGE OF CONTRACTOR 4.50 ENERGY REVIEW FEE 22:72 HOURLY PLAN CHECK r 227.50 REPLACEMENT INSP CARD 15.00 STRONG MOTION (SMI) - RES 4.00 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 614.37 614.37 .00 .00 Plan Check Total 293.41 293.41 .00 .00 Other Fee Total 275.72 256.22 .00 19.50 Grand Total 1183.50 1164.00 .00 19.50 LQPERMIT Bin #, �lt of.. La Qu1nta. Building 8f Safety. Division P.O. Box. 150¢,-7.8-495 Calle Tampico raP.Quinta, CA 92253 -:(760) 777-7012 Buildin ermit Applrcaitonand Tracking Sheet Permit # Project Address: ' Owner's Name:. ✓ —se 7 A. P. Number. Address: 5' Acm N/ Legal Description: City, ST, Zip: — 9219 S Contrarto[ r l h` e. ,� � o Telephone: Address: Project Description: �Q ' City. ST, Zip= Cfr tlt `- 0 , Telepho 76'p 5 -' R ' State Lie. #: City Lic. #; 'qcr D Arch., Engr., Designer _ �- Address-. / `, � City., ST, Zip: K -46 r— Telephone: T Construction Type:. Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft : #Stories: # Unity: Telephone # of Contact Person: ' . Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS. UNE # Submittal Pig Req'd Recd I TRACKING PERMIT FEES Plan Check submitted .� Item Amount S"durat Cales. 7- Reviewed, ready for corrections A� Plan Check Deposit. . Truss Cates: Called Contact Person Plan Check Balance. Tide 24 Cates. Plans picked up Constriction Flood plain plan Plans resubmitted.*. Mechanical Grading plan 2'! Review, ready for correcdo a Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up SALL H.O.A. Approval Plans resubmitted Grading M HOUSE:- '"` Review', ready for correedons/issie Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue h ar School Fees op Total Permit Fees i/� P.O. BOX 1504 541-1 S Av-evA, oQGk c&f 4 4aakrw LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760)777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. c A. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. . I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect *self from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 60. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on pernnts and contracts. a- W- I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. (2P16. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. (%'X/ 8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. W9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue ervice, the United States Small Business Administration, the California Department.of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. W10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for . proposed construction activity at the following address: efic4!�le I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all laws and requirements that govern Owner=Builders as well as employers. k(12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I ve provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who -does not tave a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner,and returned to the agency responsible for issuing the permit. Note: A copy of the property'owner's driver's license, form notarization, or other verification acceptable to, the agency isrequired to be presented when the permit is issued to verify the property owner's signature. Signature of property owner Date: 2/2Z Note: The following Authorization Form is required to. be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed.above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or'other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Radi Residence 54-175 Avenue Herrera La Quinta, CA Project Designer: Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: DATE ^ BY Date: 1/25/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-01-25T17:20:26 /D: I I TABLE OF CONTENTS I Cover Page 1. Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 11 HVAC System Heating and Cooling Loads Summary 14 r IEnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Radi Residence Building Type m Single Family O Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 1/25/2012 Project Address 54-175 Avenue Herrera La QuintsCA California Energy Climate Zone Climate Zone 15 Total Cond. Floor Area 2,880 Addition 0 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-11 1,859 Existing Door Opaque Door None 40 Existing Roof Wood Framed Attic R-19 1,440 Existing Slab Unheated Slab -on -Grade None 1,440 Perim = 69' Existing FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (SIM 21.0 0.710 0.73 2.0 none Bug Screen New Front (SIM 21.0 0.710 0.73 2.0 none Bug Screen New Left (NlM 10.5 0.710 0.73 2.0 none Bug Screen New Left (NW) 53.4 0.710 0.73 2.0 none Bug Screen New Rear (NE) 40.0 0.710 0.73 2.0 none Bug Screen New Right (SE) 21.0 0.710 0.73 2.0 none Bug Screen New Right (SE) 40.0 0.710 0.73 2.0 none Bug Screen New Right (SE) 40.0 0.710 0.73 2.0 none Bug Screen New Front (SIM 40.0 0.710 0.73 2.0 none Bug Screen New Front (SIM 40.0 0.710 0.73 2.0 none Bug Screen New Left (NlM 10.5 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Split Heat Pump 7.00 HSPF Split Heat Pump 13.0 SEER Setback Altered HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Existing Ducted Ducted Attic, Ceiling Ins, vented 2.1 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Elec. 50 0.87 No Pipe Insulation Altered EnerqyPro 5.1 by Ener Soft User Number: 2655 RunCode: 20 12-01-2 5 71 7:20:26 ID: Page 3 of 14 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Radi Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1/25/2012 Project Address 54-175 Avenue Herrera La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,880 Addition 0 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (NlAq 3.0 0.710 0.73 2.0 none Bug Screen New Left (NtM 10.5 0.710 0.73 2.0 none Bug Screen New Rear (NE) 10.5 0.710 0.73 2.0 none Bug Screen New Rear (NE) 40.0 0.710 0.73 2.0 none Bug Screen New Rear (NE) 20.0 0.710 0.73 2.0 none Bug Screen New Right (SE) 20.0 0.710 0.73 2.0 none Bug Screen New Right (SE) 20.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-01-25717:20:26 ID: Page 4 of 14 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Radi Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 1/25/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the'justificatibn, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The Existing Heat Pump Exist HVAC has an HSPF less than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must. receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ene Soft User Number: 2655 Run Code: 2012-01-25T17:20:26 /D: Page 5 of 14 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family_ 0 Addition Alone Date Radi Residence 1 0 Multi Family, m Existing+ Addition/Alteration 1112512012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 10.52 6.98 3.54 Space Cooling 118.03 116.69 1.33 Fans 22.56 25.19 -2.63 Domestic Hot Water 23.05 21.02 2.02 Pumps 0.00 0.00 0.00 Totals 174.16 169.89 4.27 Percent Better Than Standard: 2.4% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (Svv) 225 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (Sw) . 640 122 Fuel Available at Site: Natural Gas (Nw) 520 88 Raised Floor Area: 0 (NE) 600 111 Slab on Grade Area: 1,440 (SE):.: 600 141 Average Ceiling Height: 8.0 Roof 1,440 0 Fenestration Average U -Factor: 0.71 TOTAL: 461 Average SHGC: 0.73 Fenestration/CFA Ratio: 16.0 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the' Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 1/152012 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company 60 SfluttuY(A 531QftV-J Address `7g 08D CAtz A)14YOy 54"k102- Name AZA 1"T 4O1'&kY City/State/Zip L a Q Wok, CA • 9 225 3 Phone(7l o_) -77/_ qR q3 Signed License # Date Ener Pro 5.1 by EnerqySoft User Number.' 2655 RunCode: 2012-01-25T17:20:26 /O: Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Radi Residence Building 1 Type m ❑ Single Family O Addition Alone Multi Family m Existing+ Addition/Alteration Date 1112512012 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 238 0.110 R-11 225 90 Exisfing 4.3.1-A2 Existing Living Door 40 1.450 None 225 90 Existing 4.5.1-A1 Existing Living Wall 196 0.110 R-11 315 90 Existing 4.3.1-A2 Existing Living Wall 260 0.110 R-11 45 90 Existin : 4.3.1-A2 Existing Living Roof 68 0.049 R-19 225 0 Existin 4.2.1-A4 Existing Living Slab 1,440 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 199 0.110 R-11 135 90 Existing 4.3.1-A2 Existing Living Door 20 1.450 None 135 90 Remove 4.5.1-A1 Existing Living Wall 240 0.110 R-11 225 90 Existing 4.3.1-A2 Existing Living Wall 2361 0.110 R-11 315 90 Existing 4.3.1-A2 Existing Living Wall 230 0.110 R-11 451 90 Existing 4.3.1-A2 Existing Living Roof 1,372 0.049 R-19 225 0 Existing 4.2.1-A4 Existing Living Wall 260 0.110 R-11 135 90 Existing 4.3.1-A2 Existing Living ------------------ FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 21.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 2 Window 21.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 3 Window 21.0 0.710 Default 0.73 Default 225 New Double Metal Clear Existing Living 4 Window 21.0 0.710 Default 0.73 Default 225 New Double Metal Clear Existing Living 5 Window 17.8 1.190 Default 0.83 Default 315 Removed Single Metal Clear Existing Living 6 Window 10.5 1.190 Default 0.83 Default 315 Removed Single Metal Clear Existing Living 7 Window 10.5 0.710 Default 0.73 Default 315 New Double Metal Clear Existing Living 8 Window 53.4 1.190 Default 0.83 Default 315 Removed Single Metal Clear Existing Living 9 Window 53.4 0.710 Default 0.73 Default 315 New Double Metal Clear Existing Living 10 Window 40.0 1.190 Default 0.83 Default 45 Removed Single Metal Clear Existing Living 11 Window 40.0 0.710 Default 0.73 Default 45 New Double Metal Clear Existing Living 12 Window 21.0 1.190 Default 0.83 Default 135 Removed Single Metal Clear Existing Living 13 Window 21.01 0.710 Default 0.73 Default 135 New Double Metal Clear Existing Living 14 Window 53.41 1.190 1 Default 0.83 Default 135 Removed Single Metal Clear Existing Living 15 Window 53.41 1.190 1 Default 0.83 Default 135 Removed Single Metal Clear Existing Living 16 Window 40.01 0.710 1 Default 0.73 Default 135 New Double Metal Clear Existing Living (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt• Dist Len Right Fin Hat Dist Len H t 1 Bug Screen 0.76 3.51 6.0 2.0 0.1 2.0 2:U 2 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 i3O 3 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 2-.0- 4 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 2,0 5 Bug Screen 0.76 6.8 2.8 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 3.0 3.5 2.0 0.1 2.0 '2.0 8 Bug Screen 0.76 6.8 8.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 6.8 8.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.761 6.81 8.0 2.0 0.1 2.0 2.0 16 JBug Screen 1 0.761 6.81 6.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-01-25T17:20:26 ID: Page 7 of14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Radi Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family 10 Existing+ Addition/Alteration Date 1112512012 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID T e Area U -Factor SHGC Azm Status GlazingType Location/Comments 17 Window 40.0 0.710 Default 0.73 Default 135 New Double Metal Clear Existing Living 18 Window 40.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 19 Window 40.0 0.710 Default 0.73 Default 225 New Double Metal Clear Existing Living 20 Window 20.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 21 Window 40.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 22 Window 40.0 0.710 Default 0.73 Default 225 New Double Metal Clear Existing Living 23 Window 10.5 1.190 Default 0.83 Default 315 Removed Single Metal Clear Existing Living 24 Window 10.5 0.710 Default 0.73 Default 315 New Double Metal Clear Existing living 25 Window 3.0 1.190 Default 0.83 Default 315 Removed Single Metal Clear Existing Living 26 Window 3.0 0.710 1 Default 0.73 Default 315 New Double Metal Clear Existing Living 27 Window 10.5 1.190 Default 0.83 Default 315 Removed Single Metal Clear Existing Living 28 Window 10.5 0.710 Default 0.73 Default 315 New DoubleMeta/ Clear Existing Living 29 Window 10.5 1.190 Default 0.83 Default 45 Removed Single Metal Clear Existing Living 30 Window 10.5 0.710 Default 0.73 Default 45 New Double Metal Clear Existing Living 31 Window 20.0 1.190 Default 0.83 Default 45 Removed Single Metal Clear Existing Living 32 Window 18.0 1.190 Default 0.83 Default 45 Removed Single Metal Clear Existing Living (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt REM Dist Len H t Dist Len H t 17 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2,0 25 Bug Screen 0.76 1.0 3.0 2.0 0.1 2.0 2:a 26 Buiq Screen 0.76 1.0 3.0 2.0 0.1 2.0 2:b 27 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.b 28 Bug Screen 0.76 3.51 3.0 2.0 0.1 2.0 2.`6. 29 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 30 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 31 IBug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.01 1 32 JBug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.01 1 Ener Pro 5.1 by EnergySoft User Number.- 2655 RunCode: 2012-01-25717:20:26 ID: Page 8 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Radi Residence Building Type m Single Family; ❑ Addition Alone ❑ Multi Family. m Existing+ Addition/Alteration Date 1112512012 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 40.0 0.710 Default 0.73 Default 45 New Double Metal Clear Existing Living 34 I/l/indow 20.0 1.190 Default 0.83 Default 45 Removed Single Metal Clear Existing Living 35 Window 20.0 0.710 Default 0.73 Default 45 New Double Metal Clear Existing Living 36 Window 20.0 1.190 Default 0.83 Default 135 Removed Single Metal Clear Existing Living 37 Window 20.0 0.710 Default 0.73 Default 135 New Double Metal Clear Existing Living 38 Window 20.0 1.190 Default 0.83 Default 135 Removed Single Metal Clear Existing Living 39 Window 20.0 0.710 Default 0.73 Default 135 New Double Metal Clear Existing Living 40 Window 24.0 1.190 Default 0.83 Default 135 Removed Single Metal Clear Existing Living (1) Ll-Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window -Hqt TWd Ove hanq Left Fin Right Fin Len H t I LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 34 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 35 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 36 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 37 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 38 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 39 Bug Screen 0.76 3.0 8.0 2.0 0.1 2.0 2.0 40 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by Ener Soft User Number. 2655 RunCode: 2012-01-25717:20:26 ID: Pae 9 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Radi Residence Building Type 10 Single Family' ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 1112512012 BUILDING ZONE INFORMATION System Name Floor Area . Zone Name New Existing . Altered Removed Volume Year Built Existing Existing Living 1,440 11,520 1979 Existing Living 1,440 11,520 1979 Totals 0 2,8801 0 0 HVAC SYSTEMS System Name C!y. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing 2 Split Heat Pump 7.00 HSPF Split Heat Pump 13.0 SEER Setback Altered pre-altered for above Packaged Heat Pum 5.00 HSPF Packaged Heat Pump ' 10.0 SEER Setback HVAC DISTRIBUTION System Name Duct Heating Cooling Duct Location R-Value Ducts Tested? Status Existing Ducted Ducted Attic, Ceiling Ins, vented 2.1 ❑ Existing pre-altered for above Ducted Ducted Attic, Ceiling Ins, vented 2.1 ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh) Tank Cap. Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status AO SMITH PEC-050 1 Small Elec. No Pipe Insulation 15,359 _WaIL *,50 0.87 n/a n/a Altered Existing 1 Small Elec. pre-altered for Above 15,3591 28 0.80 n/a n/a MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) 0 i� 0 (h Q — System Name Pipe Len th Pipe Diameter Insul. Thick. Qty.THP Plenum Outside Buried El ❑ EnergyPro 5.1 by Ener Soft User Number.' 2655 RunCode: 2012-01-25T17:20:26,. ID: Pae 10 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Radi Residence Date 1 1/25/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is too greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. , §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insuldtion R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(')3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-01-25T17:20:26 ID: Page 11 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Radi Residence 1 1/25/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.272007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cove. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, i i.' ,'filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an`efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.`1: 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-01-25717:20:26 ID: Page 12 of 14 MANDATORY MEASURES SUMMARY: Residential :• (Page 3 of 3 MF -1 R Project Name Date Radi Residence 1/25/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided.that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a'residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or;bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch'that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. •i EnergyPro 5.1 by EnergySofr User Number: 2655 Run Code: 2012-01-25T17:20:26','. ID: Page 13 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Radi Residence Date 1/25/2012 System Name Existing Floor Area 2,880 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 3,048 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 47,500 50,001 4,331 1,099 42,055 Total Output Btuh 95,000 0 Output Btuh/s ft 33.0 5,180 2,578 Cooling System 0 0 Output per System 47,000 0 0 0 0 Total Output Btuh 94,000 0 4,331 0 Total Output Tons 7.8 1 5,180 2,578 Total Output Btuh/s ft 32.6 Total Output s ft/Ton 367.7 1 60,360 47,211 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 CARRIER 50HS-048 --- 301- 62,860 22,894 59,334 Airflow cfm/s ft 1.11 10.0 kW Supplemental Electric 68,260 Airflow cfm/Ton 408.5 Outside Air % 0.0 % Total Adjusted System Output 1 62,860 22,894 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P M 127,594 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS jAirstream Temperatures at Time of Heating Peak 26 OF No Outside Air 0 cfm 69 OF 69 OF 87 OF 107 OF 107 OF Heating Coil Aux. Heat Coil Supply Fan 3,200 cfm 106 F ROOM o 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooli ng Peak 112/78°F Outside Air 0 cfm 80/67°F 80/67°F 61/60°F 61/60°F , Cooling Coil Supply Fan 63 / 61 OF 3,200 cfm , 53.8% ROOM 78/66°F EnergyPro5.1 by EnergySoff User Number: 2655 RunCode: 2012-01-25717:20:26 /D: Page 14 of 14 I