Loading...
13-1592 (SFD) Revision 1Bin # Permit #'(��- Project Address: City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico . La Quinta, CA 92253 - (760) 777-7012. Building Permit Application and Tracking Sheet '6O —5:5-1V lA P Owner's Name: 5j5:Ve- 6410 t -r A. P. Number: '1-1-7-160-039 Address: Z?-( Co% 6v&,If tet: Legal Description: ,Lo`% 33,61 � �o $" City, ST, Zip: Gos S CA Contractor: Telephone: Address: Amount Project Description: City, ST, Zip:. V,4— I'D /L,o-) M.4sti4 Telephone: :>:_.::.;;::::,....•: H..,,.......:. State Lic. 4: Truss Cafes. City Lic. if.. Arch_, Engr., Designer: or, l%5JeJ J 50cItA iz;5. l Address: 3-026 41'wy o City, ST, Zip: Telephone: 6o -7-7 66v j :->:::.:.::.>.::== .. >-»::><:: Construction Type: J-15 Occupancy: Poecttype circle one): New ddnAlter Repair Demorj State Lic. #: Mame of Contact Person: Aly:� Al co 5Ce Sq. Ft.:,4 _ # Stories: € Units: I•clephone # of Contact Person: '775-66o7 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE it l l� Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Cheek submitted Item Amount Structural Calcs. "Reviewed, r dy for corrections Plan Cheek Deposit Truss Cafes. Called Contact Person l Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correclionsfissue Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. I-I.O.A. Approval Plans resubmitted Grading IN IIOUSE:- ''" Review, ready for corrcctionsrissue Developer Impact Fe._ Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fccs Total Permit Fees 1 q. Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT : LEVEL TWO AMOUNT: N. ITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: TMTIALS .CERTIFICATE OF.COMPLIANCE (California Education Code 17620) Project Name: -he Hideaway Date: February 8, 2016 Owner's Name: Steven and Gerri Elliot Phone No. Project Address: 80-559 Via Pessaro, LaQuinta , Project Description: Addition while under construction - APN: 777-160-039 Tract #: Lot #'s: Type of Development: Residential XX Commercial Total Square Feet of Building Area: 100 Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: February 8, 2016 Signature: ********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE P OJE T HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCL O ) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 100 $3.36 $336.00 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: a��acrk NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day peri3d to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other appl -cable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on tle date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. A•1V:c/mydoc�`dcvfecs/certiticateofcompliance Form updated 3-2007 11/2010 ' {f BUILDING ENERGY ANALYSIS REPORT PROJECT: Elliott Residence Lots 304 & 305 Via Pessaro La Quinta, CA 92253 Project Designer: Ochoa Design Assocoates 72626 Highway 111 Palm Desert, CA 92260 760-773-6605 Report Prepared by: Butch White BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 Job Number: D-9327 Date: 2/1/2016 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE ql b BY 'OFf►C-C (�5(DN 2 - The EnergyPro computer program has been used to perform the calculations summarized In this compliance report. This program has approval and is authorized by the Cafrfornia Energy Commisslon for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. Ene Pro 5. 1 6Z En orgySoft User Number: 3665 RunCode: 2016-02-011'08:42:43 M. D-9327 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary I.EnergyPro 5.1 by EnergySoft Job Number. ID: D-9327 User Number. 3665 1 2 3 14 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Elliott Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/1/2016 Project Address Lots 304 & 305 Via Pessaro La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,171 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. © Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ftz Features see Part 2 of 5 Status Wall Wood Framed R-21 9,307 New Slab Unheated Slab -on -Grade None 8,171 Perim = 799' New Roof Wood Framed Attic R-38 8,171 Radiant Bawler New Door Opaque Door None 92 New FENESTRATION Orientation Area fiz U- Exterior Factor SHGC Overhang Sidefins Shades Status Front (N) 22.0 0.410 0.28 4.0 none Bug Screen New Front (N) 130.0 0.320 0.25 4.0 none Bug Screen New Front (NE) 6.0 0.320 0.25 none none Bug Screen New Front (NE) 42.0 0.320 0.25 4.0 none Bug Screen New Rear (S) 44.0 0.410 0.28 4.0 none Bug Screen New Rear (S) 4.0 0.410 0.28 none none Bug Screen New Right (Kq 26.0 0.410 0.28 none none Bug Screen New Right (W) 44.0 0.410 0.28 4.0 none Bug Screen New Rear (S) 340.6 0.320 0.25 4.0 none Bug Screen New Left '(E) 8.0 0.410 0.28 none none Bug Screen New Leff (E) 174.0 0.320 0.25 4.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Sp.91 Air Conditioner 16.0 SEER Setbe ck New 1 Central Furnace 80% AFUE Sp'It Air Conditioner 16.0 SEER Setbe ck New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setbeck New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC System 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC System 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC System 3 Ducted Ducted Attic, Ceiling ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 3 Small Gas 50 0.62 Kitchen Plpe Ins New Ener Pro 5,4 by Ener Soft User Number. 3665 RunCode:.2016-02-01T08:42:43 ID: D-9327 Pa e'3 of 16 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Elliott Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Afteration Date V1/2016 Project Address Lots 304 & 305 Via Pessaro La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,171 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST 0 Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ff) Features see Part 2 of 5 Status FENESTRATION Orientation Area(ft) U- Exterior Factor SHGC Overhang Sidefins Shades Status Front (N) 80.0 0.410 0.25 10.0 none Bug Screen New Front (N) 44.0 0.410 0.25 6.0 none Bug Screen New Rear (S) 195.0 0.410 0.25 4.0 none Bug Screen New Left (E) 60.0 0.410 0.25 4.0 none Bug Screen New Right (IM 10.0 0.320 0.25. 4.0 none Bug Screen New Right (IM 140:0 0.410 0.25 6.0 none Bug Screen New Front (N) 19.6 0.320 0.25 none none Bug Screen New Left (E) 33.0 0.410 0.28 6.0 none Bug Screen New Left (E) 4.0 0.320 0.25 none none Bug Screen New Right (1" 54.0 0.410 0.25 none none Bug Screen New Right (W) 12.8 0.320 0.25 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status ` 1 Central Furnace 80% AFUE Split Air Condittoner 16.0 SEER Setback New 1 Central Fumace 80% AFUE. Split Air Condltloner 16.0 SEER Setback. New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC System 4 Ducted Ducted Attic, Celling Ins, vented 8.0 New HVAC System 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number., 3665 RunCode: 2016-02-01T08..42:43 1D: D-9327 Page 4 of 16 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name El otf Residence Building Type Gil Single Family ❑ Addition Alone 1 ❑ Mufti Family ❑ Existing+ Addition/Alteration Date 2/1/2016 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the Items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of then justification, and may reject a building or design that otherwise complies based on the adequacy of the special iustification and documentation submitted. The Roof R-38 RoofAttic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified In Residential Appendix RA4.2.2. The Roof R-38 Roof Attic Concrete Tile 10 /sf) Roofing requires verification. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures. listed below for final to be given. The Cooling System Maytag CSA4BF048K includes credit for a 13.0 EER. Condenser. A certified HERS rater must field verify the Installation -of the correct Condenser. The HVAC System HVAC System 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System 1 Incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing Is required to verify that duct leakage meats the specified criteria. The Cooling System Maytag CSA4BF024K Includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the Installation of the correct Condenser. The HVAC System HVAC System 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The Cooling System Maytag CSA4BF046K includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the Installation of the correct Condenser. The HVAC System HVAC System 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display, The HVAC System HVAC System 3 Incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing Is required to verify that duct leakage meets the specified criteria. The Cooling System Maytag CSA4BF060K includes credit for a 13.0 EER Condenser. A cartified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System 4 Incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System 4 Incorporates HERS verified Duct Leakage. 'HERS field verification and diagnostic testing Is required to verify that duct leakage meets the specified criteria. The Cooling System Maytag CSA4BF060K includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the Installation of the correct Condenser. Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2016-02-01T08:42:43 ID: D-9327 Pae 5 of 16 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name Elliott Residence Building Type m Single Family 0 Addition Alone ❑ Multi Family 0 Existing+ Additlon/Alteration Date 1 211/2016 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require. field testing and/or verification by a certified HERS Rater. The inspector must receive a completed GF-4R form for each of the measures listed below for final to be given. The HVAC System HVAC System 5 Incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System 5 Incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing Is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number.- 3665 RunCode: 2016-02-01T08:42:43 ID: D-9327 Pa e 6 of 16 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date Elliott Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 2/1/2016 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV ki3tu/ft2- r Space Heating 4.66 5.59 -0.93 Space Cooling 52.95 39.74 13.21 Fans 10.59 12.74 -2.14 Domestic Hot Water 4.46 6.22 -1.75 Pu m s 0.00 0.00 0.00 Totals 72.67 64.28 8.39 Percent Better Than Standard: 11.5% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0dog Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 2,616 344 Fuel Available at Site: Natural Gas (E) 2,688 279 Raised Floor Area: 0 (S) 2,304 564 Slab on Grade Area: 8,171 (A9 2,460 287 Average Ceiling Height: 10.0 Roof 8,171 0 Fenestration Average U -Factor: 0.37 TOTAL: 1,493 Average SHGC: 0.26 Fenestration/CFA Ratio: 18.3 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications- needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING Address 75-145 St. Charles Place Name Butch White 2/1/2016 City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760)'346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner.(per Business & Professions Code) Company Ochoa Design Assocoates Address 72626 Highway 111 Name Juan Carlos Ochoa City/State/Zip Palm Desert, CA 92260 Phone 760-773-6605 Signed License # Date . Ener Pro &J by Ener Soft User Number., 3665 RunCods: 201E 02-O1T08:42.43 ID: D-9327 Pae 7 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Elliott Residence Building Type m Single Family ❑ Addition Alore 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 21112016 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interlor Frame Azm Joint Appe-idix Tilt Status 4 Location/Comments .Wal/ 354 0.069 R-21 0 90 New 4.3..1-A6 Zone 1 Wall 312 0.069 R-21 45 90 New 4.3.1 A6 Zone 1 Wall 420 0.069 R-21 135 90 New 4.3.1 A6 Zone 1 Wall 3481 0.069 R-21 901 90 1 New 4.3.1-A6 Zone 1 Wall 204 0.069 R-21 180 90 New 4.3.1-A6 Zone 1 Wall 408 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 Slab 1,363 0.730 None 0 180 New 4.4.7-A1 Zone 1 Roof 1,363 0.025 R-38 0 0 New 4.2.1-A21 Zone 1 Demising 70 0.069 R-21 0 90 New 4.3.1-A6 Zone 1 faces Master Sulh Wall 3121 0.069 R-21 0 90 New 4.3.1-A6 Zone 2 Wall 1461 0.069 R-21 180 90 New 4.3.1-A6 Zone 2 Dem/sing 1321 0.069 R-21 0 90 New 4.3.1-A6 Zone 2 faces Theater, W Wall 200 0.069 R-21 90 90 New 4.3.1-A6 Zone 2 Wall 300 0.069 R-21 270 90 1 New 4.3.1-A6 Zone 2 Slab 1,246 0.730 None 01 180 New 4.4.7-A1 Zone 2 Roof 1, 2461- 0:025 R-38 0 0 New 4.2:1-A21 Zone 2- " FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC4 Azm Status Glazing Type Location/Comments 1 Window 22.0 0.410 NFRC 0.28 1 NFRC 0 New Loewen Mdclad D272 Opereole Zone 1 2 Window 6.0 0.320 NFRC 0.25 NFRC 0 New Loewen Mdclad D272 Fixed Zone 1 3 Window 6.0 0.320 NFRC 0.25 NFRC 45 New Loewen Mdclad D272 Fixed Zone 1 4 Window 12.0 0,320 NFRC 0.25 NFRC 45 New Loewen Mdclad D272 Fixed Zone 1 5 Window 12.0 0.320 NFRC 0.25 NFRC 45 New Loewen Mdclad 0272 Fixed Zone 1 6 Window 12.0 0.320 NFRC 0.25 NFRC 45 New Loewen Mticlad D272 Fixed Zone 1 7 Window 6.0 0.320 NFRC .0.25 NFRC 45 New Loewen Mticlad D272 Fixed Zone 1 8 Window 22.0 0.410 NFRC 0.28 NFRC 180 New Loewen Mticlad D272 Operable Zone 1 . 9 Widow 22.0 0.410 NFRC 0.28 NFRC 180 New Loewen Mt/clad D272 Operable Zone 1 10 Window 2.0 0.410 NFRC 0.28 NFRC 180 Now Loewen Mt/clad D272 Operable Zone 1 11 Window 2.0 0.410 NFRC 0.28 NFRC 180 New Loewen Mdclad D272 Operable Zone 1 12 Window 2.0 0.410 NFRC 0.28 NFRC 270 New Loewen Mt/clad D272 Operable Zone 1 13 Window 2.0 0.410 NFRC 0.28 NFRC 270 New Loewen Mtic/ad D272 O eradle Zone 1 14 Window 22.0 0:410 NFRC 0.28 NFRC 270 New Loewen Mt/clad D272 Operaale Zone 1 15 Window 22.0 0.410 NFRC 0.28 NFRC 270 New Loewen Mtic/ad D272 Operaofe Zone 1 16 Window 12.0 0.320 NFRC 0.25 NFRC 0 New _o LM!xed D2F_. . Z_on_e 2 . . (1) 1.1 -Factor Type: 116-A = Default Table from Standards, NFRC - Labeled Value 2 SHGC T. e: 116-B - Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window. H t I Wd Ove hang Left -Fin Right Fin Len Hq t LExt REA Dist Len H t Dist Len H t 1 Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 2 Bug Screen 0.76 4.0 2.0 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 4 Bug Screen 0.76 0.5 2.0 4.0 0.1 4.0 4.0 5 Bug Screen 0.76 5.5 2.0 4.01 0.1 4.01 4.0 6 Bug Screen 0.76 5.51 2.0 4.01 0.1 4.01 4.0 7 Bug Screen 0.76 3.01 2.0 4.0 0.1 4.0 4.0 8 Bug Screen 0.76 5.5 4.0 4.0 0.1 4:0 4.0 9 Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 10 Bug Screen 0.75 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14' Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 15 uq Screen 0.76 16 Bu Screen 0.76 4.0 3.0 4.0 0.1 4.0 4.0 EnergyPro 5.1 by Ener Soft User Number: 3665 RunCode: 2016.02-01 T08:42:43 ID: D-9327 Page 8 of 1 B CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Elliott Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Acdition/Alteration Date 211/2016 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 300 0.069 R-21 0 90 New 4.3.1A6 Zone 3 Demising 144 0.069 R-21 0 90 New 4.3.1A6 Zone 3 faces Bedroom 3 Wall 336 0.069 R-21 180 90 New 4.3.1-A6 Zone 3 well 468 0.069 R-21 901 90 1 New 4.3.1-A6 Zone 3 Wall 530 0.069 R-21 2701 90 1 New 4.3. i A6 Zone 3 Door 24 0.500 None 270 90 New 4.5.1-A4 Zone 3 Slab 1,614 0.730 None 0 180 New 4.4.7A1 Zone Roof 1,614 0.025 R-38 0 0 New 4.2.1 A21 Zone 3 Wall 360 0.069 R-21 0 90 New 4.3.1-A6 Zone 4 Demising 336 0.069 R-21 0 90 New 4.3.1-A6 Zone 4 faces Theater, W Wall 564 0.069 R-21 180 90 1 New 4.3.1-A6 Zone 4 Wall 450 0.069 R-21 901 90 1 New 4.3.1-A6 Zone 4 Wall 414 0.069 R-21 270 90 New 4.3.1-A6 Zone 4 Slab 1,546 0.730 None 1 0 180 1 New 4.4.7-A1 Zone 4 Roof 1,546 0,025 R-38 0 0 New 4.2.1-A21 Zone 4 Wall 586 0.069 R-21 0 90 1 New 143.17A6 lZone 5 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 22.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 2 18 Window 2.0 0.410 NFRC 0.26 NFRC 90 New Loewen Mt/clad D272 Operable Zone 2 19 Window 2.0 0.410 NFRC 0.28 NFRC 90 New Loewen Mt/clad D272 Operable Zone 2 20 Window 32.0 0.320 NFRC 0.25 !NFRC 90 New Loewen Mt/clad D272 Fixed Zone 3 21 Window 32.0 0.320 NFRC 0.25 NFRC 90 New I Loewen Mt/clad D272 Fixed Zone 3 22 Window 22.0 0.3201 NFRC 0.25 NFRC 90 New Loewen Mt/clad D272 Fixed Zone 3 23 Window 22.0 0.320 NFRC 0.25 NFRC 90 New Loewen Mticlad D272 Fixed Zone 3 24 Window 22.0 0.410 NFRC 0.28 NFRC 270 New Loewen Mflcled D272 Operable Zone 3 25 Window 40.0 0.320 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Fixed Zone 4 26 Window 40.0 0.320 NFRC .0.25 NFRC 0 New Loewen Mticlad D272 Flxed Zone 4 27 Window 80.0 0,410 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Slider Zone 4 28 Window 22.0 0.410-,NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Slider Zone 4 29 Window 22.0 0.410 NFRC 0.25 NFRC 0 New Loewen Mt/clad D272 Slider Zone 4 30 Window 40.0 0.320 NFRC 0.25 NFRC 180 New Loewen M1/clad D272 Fixed Zone 4 31 Window 40.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 4 32 Window 33.0 0.320 NFRC 0.25 1 NFRC 180 New Loewen Mticlad D272 Fixed Zone 4 (i) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-6, - Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window. Hot Wd Ove hang; Left Fin Ri ht Fin Len HILExt RExt Dist Len Hot Dist Len Hot 17 Bug Screen 0.16 5.5 4.0 4.0 0.1 4.0 4.0 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 6.5 5.0 4.0 0.1 4.0 4.0 21 Bug Screen 0.76 6.51 5.0 4.0 0.1 4.0 4.0 22 Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 23 Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 24 Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 25 Bug Screen 0.76 8.8 4.5 4.0 0.1 4.0 4.0 26 Bug Screen 0.76 8.8 4.5 4.0 0.1 4.0 4.0 27 Bug Screen 0.76 8.0 10..0 10.0 0.1 10.0 10.0 28 Bug Screen 0.76 5.5 4.0 6.0 0,1 6:0 6.0 29 _Bug Screen 0.76 5.5 4.0 6.0 0.1 6.0 6.0 30 Bug Screen 0.76 8.8 4:5 4.0 0.1 4.0 4.0 31 Bug Screen 0.76 8.8 4.5 4.0 0.1 4.0 4.0 32 Bu Screen 0.76 6.5 5.0 4.0 0.1 4.0 4.0 Ener Pro 5.1 by EnergySoft User Number., 3665 RunCode: 2016-02-01T08:42.43 ID: D-9327 Pae 9 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Elliott Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteratlon Date 2/1/2016 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavlt Exterior Frame Interior Frame Azm I Joint Appendix Tilt Status 4 LocationlComments Door 48 0.500. None 0 90 New 4.5.1-A4 Zone 5 Well 450 0.069 R-21 180 90 New 4.3.1 A6 Zone 5 Door 20 0.500 None 180 90 New 4.5.1 A4 Zone 5 Wall 5231 0.069 R-21 90 90 New 4.3.1 A6 Zone 5 Wall 497 0.069 R-21 270 90 New 4.3.1-A6 Zone 5 Demising 72 0.069 R-21 0 90 New 4.3.1A6 Zone 5 faces Theater, W Slab 2,.402 0.730 None 01 180 New 4.4.7-A 1 Zone 5 Roof 2,402 0.025 R-38 01 0 New 4.2.1-A21 Zone 5 Demising 70 0.069 R-21 0 90 New 4.3.1 A8 Zone 5 faces Guest Caslt FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm :Status Glazing Type Location/Comments 33 Window 33.0 0. 3201 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 4 34 Window 33.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 4 35 Window 22.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 4 36 Window 99.0 0.410 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Slider Zone 4 37 Window 33.0 0.320 NFRC 0.25 NFRC 90 New I Loewen Mticlad D272 Fixed Zone 4 38 Window 33.0 0.320 NFRC 0.25 NFRC 90 New I Loewen Mt/clad D272 Fixed Zone 4 39 Window 60.0 0.4101 NFRC 0.25 NFRC 90 New Loewen Mt/clad D272 Slider Zone 4 40 , tMndow 10.0 0.320 NFRC 0.25 NFRC 270 New Loewen Mticlad D272 Fixed Zone 4 41 W/ndow 100.0 .0.410 NFRC 0.25 NFRC 270 New Loewen Mticlad D272 Slider Zone 4 42 Window 40.0 0.410 NFRC 0.25 NFRC 270 New Loewen Mticlad D272 Slider Zone 4 43 Window 12.0 0,320 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Fixed Zone 5 44 Window 4.0 0.320 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Fixed Zone 5 45: tMndow 4.0 0,320 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Fixed Zone 5 46 W/ndow 4.0 0.320 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Fixed Zone 5 47 Window 3.8 0.3201 NFRC 0.25 NFRC 0 New Loewen Mticlad D272 Fixed Zone 5 48 Window 3.8 0; 3201 NFRC 0.25 NFRC 0 New lLoewenM11c1adD272F1.xed Zone 5 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC 'Window H t I Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 6.5 5.0 4.0 0.1 4:0 4.0 34 Bug Screen 0.76 6.5 5.0 4.0 0.1 4.0 4.0 35 Bug Screen 0.76 5.5 4.0 4.0 0.1 4.0 4.0 36 Bug Screen 0.76 11.0 9.0 4.0 0.1 4.0 4.0 37 Bug Screen 0.76 6.5 5.0 4.01 0.1 4.01 4.0 36 Bug Screen 0.76 6.5 5.0 4.0 0.1 4.0 4.0 39 Bug Screen 0.76 10.01 6.0 4.0 0.1 4.0 4.0 40 Bug Screen 0.76 2.0 5.0 4.0 0.1 4.0 4.0 41 Bug Screen 0.76 10.0 10.0 6.0 0.1 6.0 6.0 42 Bu2 Screen 0.76 8.0 5.0 6.0 0.1 6.0 6.0 43 Bug Screen 0.76 2.0 6.0 4.0 0.1 4.0 4.0 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Buq Screen 0.76 EnergyPro 5.1 by Ener Soft User Number: 3665 RunCode: 2016-02-01708:42:43 1D: D-9327 Pae 10o CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Elliott Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/1/2016 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 9.0 0.320 NFRC 0. 251 NFRC 0 New Loewen Mticlad D272 Fixed Zone 5 50 Window 9.0 0.320 NFRC 0.25 NFRC 0 New Loewen MUclad D272 Fixed Zone 5 51 Window 3.8 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 5 52 Window 24.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 5 53 Window 46.0 0.410 NFRC 0.25• NFRC 180 New Loewen Mticlad D272 Slider Zone 5 54 Window 11.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 5 55 Window 24.0 0.320 NFRC 0.25 NFRC 180 New Loewen MUclad D272 Rxed Zone 5 56 Window . 22.0 0.320, NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 5 57 Window 11.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 5 58 Window 48.0 0.410 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Slider Zone 5 59 Window 22.0 0.320 NFRC 0.25 NFRC 180 New Loewen Mticlad D272 Fixed Zone 5 60 Window 33.0 0.410 NFRC 0.28 NFRC 90 New Loewen Mticlad D272 Operable Zone 5 61 Window 2.0 0.320 NFRC 0.25 NFRC 90 New Loewen Mticlad D272 Fixed Zone 5 62 IMndow 2.0 0.320 NFRC 0.25 NFRC 90 New Loewen Mticlad D272 Fixed Zone 5 63 Window 2.0 0.410 NFRC 0.28 NFRC 90 New Loewen Mticlad D272 Operable Zone 5 64 Window 2.0 0.490 NFRC 0.28 NFRC 90 New Loewen Mticlad D272 Operable Zone 5 (1) U -Factor Type: 2 SHGC Type: 116-A - Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS. ID Exterior Shade T SHGC Window Hat Wd Ove hang Left Fin Right Fin Len H LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 4.5 2.0 4.0 0.1 4.0 4.0 50 Bug Screen 0.76 4.5 2.0 4.0 0.1 4.0 4.0 51 Bug Screen 0.76 2.5 1.5 4.0 0.1 4.0 4.0 52 Bug Screen 0.76 8.0 3.0 4.0 0.1 4.0 4.0 53 Bug Screen 0.76 8.0 6.0 4.01 0.1 4.01 4.0 54 Bug Screen 0.76 2.01 6.0 4.0 0.1 4.0 4.0 55 Bug Screen 0.76 8.0 3.0 4.0 0.1 4.0 4.0 56 Bug Screen 0.76 8.0 2.7 4.0 0.1 4.0 4.0 57 Bug Screen 0.76 2.0 6.0 4.0 0.1 4.0 4.0 58 Bug Screen 0.76 8.0 6.0 4.0 0.1 4.0 4.0 59 Bug Screen 0.76 8.0 2.7 4.0 0.1 4.01 4.0 60 Bug Screen 0.76 5.51 6.0 6.0 0.1 6.0 6.0 61 _Bug Screen 0.76 62 Bug Screen 0.76 63 JBug Screen 0.76 64 Bu Screen 0.76 EnergyPro 5.1 by Ener Soft User Number: 3665 RunCode: 2016-02-01708:42:43 ID: D-9327 Pae 11 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Elliott Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/1/2016 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Locatlon/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 65 Window 54.0 0,410 NFRC 0.25 NFRC 270 New Loewen Mt/clad D272 Slider Zone 5 66 VVndow 3.8 0.320 NFRC 0.25 NFRC 270 New Loewen Mt/clad D272 Fixed Zone 5 67 tMndow 3.0 0.320 NFRC 0.25 NFRC 270 New Loewen Mticlad D272 Fixed Zone 5 68 W/ndow 3.0 0.320 NFRC 0.25 NFRC 270 New 1 Loewen Mt/clad D272 Fixed Zone 5 69 Window 3.0 0.320 NFRC 0.25 NFRC 270 New Loewen Mt/clad D272 Fixed Zone 5 (1) U -Factor Type: 2) SHGC Type: 116-A =Default Table from Standards, NFRC = Labeled Value 116-B -Default Table from Standards NFRC =Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window Ove ang Left Fin Right Fin SHGC H FTWVd Len H t LExt REA Dist Len H t Dist Len H t 65 Bug Screen 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 EnergyPro 5.1 by EnergySoff User Number, 3665 RunCode: 2016-02.01T08:42:43 ID: D-9327 Pae 12 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF-1 R Project Name Elliott Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/1/2016 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built HVAC System 1 Guest Caslta 1,363 13,630 HVAC System 2 Bedroom 3 Suite 1,246 12,460 HVAC System 3 Theater, W Gallery, Pantry 1,614 16,140 HVAC System 4 GrtRm, Kitchen, Gallery, Foyer 1,546 15,460 HVAC System 5 Master Suite, BRZ Office 2402 24,020 Totals 6,171 0 01 0 HVAC SYSTEMS System Name Qt . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 1 Central Furnace 80% AFUE Split Air Con ditloner 16.0 SEER Setback New HVAC System 2 1 Central Furnace 80'1 AFUE Split Air Conditioner 16.0 SEER Setback New HVAC System 3 1 Central Furnace 80.116 AFUE Split Air Conditioner 16.0 SEER Setback New HVAC System 4 1 Central Furnace 80.116 AFUE Split Air Conditioner 16.0 SEER Setback New HVAC System 5 1 Central Furnace80•- AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R-Value Ducts Tested? Status HVAC System 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC System 2 Ducted Ducted Attic, Gelling Ins, vented 8.0 ❑ New HVAC System 3 Ducted Ducted Attic, Ceiling lns, vented 8.0 fin New .HVAC System 4 " - Ducted Dueled Attic, Ceiling Ins, vented 0.01, - N®w HVAC System 5 Ducted Ducted Attic, Ceiling Ins, vented 8.01 ® JNew WATER HEATING SYSTEMS S stem Name City. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank. Insul. R- Value Status A 0 Smith Water Products 3 Small Gas Kitchen Pipe Ins 37,000 50 0.62 n/a n/a New MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E zt� 2 w a Hot Water Piping Length (ft)o v c Q — -System Name Pipe Len th Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Burled ❑ ❑ ❑ ❑ Ene rgyPro 5.1 by EnerqySoft User Number., 3665 RunCode: 2016.02.01708:42:43 1D: D-9327 Pae 13 of 16 MANDATORY MEASURES SUMMARY: Residential Pae 1 of3 MF -1 R Project NameDate Elliott Residence 2/9/2016 NOTE:. Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: §11 &(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products. (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient (SHOC), and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent L1 factor. §150(b); Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall ore c uivalent U -factor. 11 Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e l A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches In area and is equipped with a with a readily accessible., operable, and t1ght-fitting damper and or a combustion -air cont,ol device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and.Plumbllng System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow, prevention, pump.isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household. cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. I 50(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. _ 150(i): Heatin6 systems are equipped with thermostats that meet the setback requirements of Section 1 12 c . §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. .§1500)1 B: Unflred storage tanks, such as storage tanks or backup tanks for solar water -heating system., or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -.recirculating systems, and entire length of recirculating sections of hot water pipes are Insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. .§1500)3A: Insulation for chilled. water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in cbnditloned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating. and Certification Corporation. EnergyPro5.1 by EnergySoft User -Number. • 3665 RunCode: 2016-02-01T08:42:43 ID, D-9327 Page 14 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Elliott Residence 2/1/2016 §150(m)1: All air-distribution system ducts and plenums Installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R.- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. It mastic or tape Is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions In the cross-sectional area of. the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150.(m)7: Exhaust fans stems have back draft or automatic .dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that Is water retardant and provides shielding from solar radiation that cari cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASH RAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a .heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters and valve requirements of §150 Resldentlal Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminalre asspecified by §150(k)2. 150 k 3: The wattage of permaryently installed luminaires shall' be determined as specified by §130(d), §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently. installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall, contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-0 and -shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150.(k)6: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable. control system; and all permanently installed luminaries in-garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.9 by EnergySoft User Number. • 3665 RunCode: 2096.02-09708:42:43 ID: D-9327 Page 15 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Elliott Residence 2/1/2016 §150(k)10: Permanently Installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119, EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently Installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site Is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance Insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminalre housing and ceiling, §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios In low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently.mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that--. they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of ower as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements In Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of law -rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §111'9. Energy.Pro 5.9 by EhergySoft User Number: 3665 RunCode: 2046-02-04T08:42:43 !D: D-9327 Page 16 of 16