Loading...
SA 2014-1034u�itrGv P.O. Sox 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLC TAMPICO (760) 7 7 7 - 7 0 0 0 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7101 October 3, 2014 Mr. Bill Sigurdsen Sign*A*Rama 41945 Boardwalk Palm Desert, CA 92211 SUBJECT: SIGN PERMIT APPLICATION 2014-1034: LA QUINTA CLIFF HOUSE MONUMENT REVISION Dear Mr. Sigurdsen: The Community Development Department has reviewed and approved your request for modification of one (1) freestanding monument sign, to add internally illuminated business identification copy for the La Quinta Cliff House, located at 78250 Highway 111. This sign is approved per the sign exhibits enclosed, subject to the following Conditions: 1. This sign permit grants one (1) freestanding internally illuminated building monument sign for business identification, reading "La Quinta Cliff House Grill & Bar". The sign copy area shall not exceed 28.5 square feet, and shall be designed and placed in conformance with the sign graphics on file with this application. 2. The sign monument shall remain in the same location as previously existing or, if removed to facilitate the sign installation, shall be replaced in generally the same prior location. 3. The applicant is required to obtain a building permit prior to the placement of this sign. The Building Division can be reached at (760) 777-7012. Should you have any questions or need additional information please feel free to contact me at (760) 777-7125. Sincerely, Wallace Nesbit Principal Planner c: Building Division Code Compliance Documentation Author's Declaration Statement • I certify that this Certificate-ofCompliance documentation is accurate and complete. Name // CC ., - Signature §133(a)l. All signs with permanently connected lighting are controlled with an automatic time switch control Company � � n Date �v Addressj r , ` b ��-�� �L I "I `1 J I f applicable: CEA k O CEPE M CityrwattJLip ✓��) 1 Pho 76rj "72 p `%. t 5 0-7 Principal Lighting Designer's Declaration Statement • 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the lighting design. • This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24. Pages I and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance fomts, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. . j e,.-)si8„ature Nsme: 13 116.1� 1�'j '2122� Company: Pho 760 —7- ggo7 Address: / j J License N 017,3- ). I City/Statozip: Date Sign Mandatory Measures Indicate location on building plans of Mandatory Sign Measures Note Block: Mandatory Sign Lighting Controls Yes No I §133(a)l. All signs with permanently connected lighting are controlled with an automatic time switch control that complies with the applicable requirements of § 119. O §133(a)2. All outdoor signs are controlled with a photo control or outdoor astronomical time switch control. O 2 Exception to §133(a)2. Outdoor signs are in tunnels or large covered areas that require illumination during O , daylight hours. §133(&)3. All outdoor signs arc controlled with a dimmer that provides the ability to automatically reduce O y�,r s!2 power by a minimum of 65 percent during nighttime hours. Y� Exception I to §133(x)3. Signs are illuminated for less than one hour per day during daylight hours. )a O 3 Exception 2 to §133(a)3. Outdoor signs are in tunnels or large covered areas that require illumination durizig daylight hours. Exception 3 to §133(a)3. Only metal halide, high pressure sodium, cold cathode, or neon lamps`are used to O illuminated signs or parts of signs. §133(a)4. An Electronic Message Center (EMC) having a new connected lighting power load greater t!10 15 kW has a control installed is capable of reducing the lighting power by a minimum of 30 percent wh N O NIA 10 4 receivinga demand response si al that is sent out b the local utili Exception to §133(a)4. The EMC is required by a health or life safety statue, ordinance, or regulation, N NIA includingbut not limited to exit signsfit and tmc signs. O 2008 Nonresidential Compliance Forms : t ugtw 2009 Certificate of Compliance and Field Inspection Energy Checklist (Sign Lighting). (Page 2 of 2) SLTG-IC Project Name: / ` /' / r Date: IbL-7 G1 Compliance Method Maximum Allowed Lighting Power A B C D E F G H I J K Design Complies? Light. Field Allowed Watts Watts' YIN Source Inspector. b U o ^ OCd U E X33 0w 1.0 a ¢ n 3 v Description or location and plan location ❑ 17:. ..:❑ Total Sign Area: 1. Design Watts = total connected lighting load installed in the 'sign, including power used by lamps, ballasts, transformers, power supplies, etc. 2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary, Use additional sheets i necessary. The sign(s) identified above; use only one or more of the following technologies: list all applicable numbers that apply in column.I above 1 High pressure sodium lamps 1 Pulse start or ceramic metal halide lamps served by a ballast with >_ 88% e)ftciency 3 Pulse start metal halide lamps that are <_ 310 watts, are not 250 wall or 175 watt lamps, and are served by a ballast with >_ 80% efficiency 4 Neon or cold cathode latnps with transformer or power supply efficiency >_ 75% with rated output current < 50 mA 5 Neon or cold cathode lamps with transformer or power suppI efficiency? 68% with rated outout current?! 50 mA 6 Fluorescent lamps with a minimum color rendering index CRI o 80 7 Light emitting diodes LEDs with a power supply with >_ 80% efficiency Single voltage LED external power supplies designed to convert 120 volt AC input into lower voltage DC or AC output, having a nameplate output power less than or equal to 250 watts, and 8 certified to the Energy Commission as complying with the applicable requirements of the Appliance Efficiency Regulations(Title 20 9 Com act uorescent lamps that do not contain a medium screw base sockets (E24IE26 10 Electronic ballasts with a undamental output frequency >_ 10 kHz Field Inspector Notes or Discrepancies 2008 Nonresidential Compliance Forms