Loading...
04-6770 (SFD) Revision 1� 8'es-► eon" TITLE 24 REPORT Title 24 Report for: Cornel Residence Lot 102 - Eisenhower Drive La Quinta., CA Project Designer: I OF L` ()UINTAING & SAF ED,PPRo CTIONR CON By: Joan D.. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 Job Number: Date: 1/29/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance.report. This,program has approval and°is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. Thisprogram developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. UseroNumber. 2655 49 C' &15amHOWtL IDP. C1*N-c,�' . 2®tip - ed C,- TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 7 Form C -2R Computer Method Summary 9 HVAC System Heating and Cooling Loads Summary 14 Room Load Summary 16 EnergyPro 3.1 By EnergySoft Job Number. User Number. 2655 Certificate of ComDliance: Residential (Part 1 of 2) CF -1 R Cornel Residence 1/29/2004 Project Title Date Lot 102 - Eisenhower Drive La Quinta Project Address Building Permit # Insu-form, Inc. (760) 324.-2046 Pian check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method, (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,993 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 2,993 ft2 Building Type: (check one or more) © Single Family .Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation:(Southwest) 225 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: ® Slab Floor Const: Frame Assembly ❑ Raised Floor , etc. Slab On Grade n/a 0.756 Exposed Stab w/R-0:0 Perimeter Insulation R-21 Wall (W.21.2x6:16) Wood 0.059 Exterior Wall R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0,Pedmeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading. Yes / No Yes/ No Front (SouthwesU. 30.0 0.65 0:36 Bug Screen x❑ ❑ ❑ X❑ Front (Southwest) 76.0 1.19 0.83 Bun Screen X❑ ❑ ❑ X❑ Front (Southwest) 168.3 0.43 0.36 Bug Screen 0 ❑ ❑ Q Front (Southwest) 116.0 0.55 0.40 Bug,Screen X❑ ❑ ❑ X❑ Front (West) 15.0 0.65 0.36 Buq.Screen X❑ ❑ ❑ X❑ Front (West) 4.5 0.43 0.36 Bug Screen X❑ ❑ ❑ X❑ Left (Northwest) 4.5 0.43 0.36 Buq Screen Q ❑ ❑ X❑ Left (Northwest) 15.0 0.65 0.36 Bug Screen X❑ ❑ ❑ Left (North) 15.0 0.65 0.36 Bug Screen x❑ ❑ ❑ 0 Left (North) 4.5 0.43 0.36 Buq Screen Q ❑ ❑ 0 Rear (Northeast) 15.0 0.65 0.36 Bug Screen x❑ ❑ ❑ 0 Rear (Northeast) 21.9 0.43 0:36 Bug Screen X❑ ❑ ❑ 191 Run Initiation T C 3 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Pa e:3 of 17 Certificate of ComMiance: Residential (Part 1 Of 2) CF -1R Cornel Residence 1/29/2004 Project Title Date Lot 102 -Eisenhower Drive La Quinta Project Address Building Permit # Insu-form, Inc. (760) 324-2046 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,993 ft? Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 2,993 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Southwest) 225 deg. Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: Y Slab Floor ❑ Raised Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U- actor SGC Shadin Yes / No Yes / No Right (Southeast) 57.5 1.19 0.83 Bug Screen X❑ ❑ ❑ X❑ Right (Southeast) 24.0 0.55 0.40 Bug Screen X❑ ❑ ❑ X❑ Left (Northwest) 28.5 1.19 0.83 Bug Screen X❑ ❑ ❑ X❑. Left (Northwest) 24.0 0.55 0.40 Bug Screen X❑ ❑ ❑ X❑ Rear (Northeast) 48.0 0.55 0.40 Bug Screen X❑ ❑ ❑ 0 Rear (Northeast) '25:0 0.65 0.36 Bug, Screen ❑ X❑ ❑ X❑ Right (Southeast) 11.1 0.43 0.36 Bug Screen X❑ ❑ ❑ X❑ Right (Southeast) 40.0 0.65 0.36 Bug Screen X❑ ❑ ❑ X❑ Right (Southeast) 10.0 1.28 0.80 Bug Screen 0 ❑ ❑ X❑ Skylight 4.0 0.40 0.50 None ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run'lnitlation T1124211 Run Code: EnergyPro 31 By En Soft UserNumber. 2655 Job Number. Pa e:4 of 17 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Cornel Residence 1/29/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronicor Combined Hydronie data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment, Minimum Type, and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Fumes 80% AFUE Central Fumace 80% AFUE Ducts in Attic Duds in Attic 4.2 42 Sathack Znne 1 Setback 7nne 2 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Split Air Conditioner1 .09�FER Ducts in Attic Duds in Attic 42 4.2 Sethack Znne 1 Sethack 7nne 9 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst. Btulhr (gal) Efficiency Loss (%) R -Value A.O- SMITH FPS_!�0-224 Small Gas Standard Z 43,000 50 0-62 n/a n/a For small gas storage (rated inputs of,less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated input and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title,24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize, that' compliance using duct sealing and TXV's requires installer testing and certification and field 'verification by an approved HERS rater. Designer or Owner (per•business &Professions Code) Documentation Author Name: Title/Firm: Address: 78120 CALLE•-ESTADO, SUITE 20B _L-A QUiNTA, CA 92253 Telephone: GW, . 47n!:2 Lic. #: �. �o• 6� (signature) _ (date) Enforcement Agency Name! Title/Firm: Address: Teleahone: Name: Joan D. Hacker Title/Firm: Insu-form. Inc. Address: 68-255 Corte Road Cathedral City, CA 92234 Telephone: (760) 324-2046 (signaturelstam) (date) Run InitiatlonTfinee 0112910414:42911 Run Codee 1076416131 EnergyPro 3:1 By Ene_rgySoft User Number. 2655 Job Number. Page15 of 17 Certificate of Compliance.: Residential (Addendum) CF -1 R Cornel Residence 1/29/2004 Project Title Date Special. Features and Modeling Assumptions The local enforcement agency. should pay, special attention to' the Items specified in this checklist. These items require special written justification and'documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of`the'justlfication, and may reject's building or design that otherwise complies based on the,adequacy of the special justification and documentation submitted.I Plan I Field HIGH MASS Design(see C=2R) - Verify Thermal Mass: 1494.sgft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH 'MASS :Design(see C -2R) - Verify Thermal Mass: 1499 sqft Covered.Slab Floor, 3.50",thick at Zone,2 HERS Required Verification These.features must be confirmed. and/or tested:by a certified HERS rater under the+supervision of a CECapproved HERS provider. The HERS rater must document the field. verification and'diagnostic testing of these measures on a form CF -6R. I Plan Field The HVAC' System "Zone 1'' includes Refrigerant Char9e and«Airfiow Credit (ora TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 1" is using'reduced duct leakage to complyvand must have diagnostic site testing of duct leakage performs by a certified HERS Rater. The results of the diagnostic testi ng must be reported,on a CF-6R,Form. The HVAC System "Zone 2" includes Refrigerant Charge:and'Airflow CredW(or a TXV). A certified HERS rater must provide verifification of the TXV, or measure Ahe,Refrigerant Charge and Airflow. The.HVAC System 'Zone ZZs using reduced duekleakage to comply and: must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be. reported on a CF -611 Form. R '14:42*11 Run Code: 1076416131 EnergyPro 3:1 l4yEnergySoft User Number. 2655 Job Number. Page.6 of 17 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowdse residential buildings:subject to the Standards must contain these measures regardless of the complianceapproach used. Items marked with an asterisk (•) may be.superseded by more stringent compliance requirements listed on the:Certificate of Compliance. When this checklist is incorporated into thwpennit documents, the features noted shall'be considered by all parties as minimum component.perfomrance specifications for the mandatory measures whether they are shown elsewhere In the documents or on this checklist only. DESCRIPTION Instructions: Check'or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures -§ 15Q(a): Minimum R-19 ceiling insulation. E] § 150(b): Loose fill insulation manufacturer's labeled R -Value. 1150(c): Minimum R-13 ❑ wall, insulation in wood framed walls or equivalent U -value in metal frame walls (does i( notapply to exteriormass walls). E ' § 150(d): Minimum R-13 raised floor Insulation in.framed floors or equivalent. §1500j: Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 pem Cinch. ❑X § 118: Insulation specified or installed meats Insulation quality standards. Indicate type and form. 5fl§116-17: Fenestration Products, Exterior Doors and Inflltration/Exfiltration Controls ANJ 1. Doors and windowwbetweeh conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabdcated).have label with certified 1.1 -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration cartification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(9): Vapor barriers mandatory in Climate Zones 14 and Monly. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §:150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces,have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated In accordance withASHRAE, SMACNA or RCCA, a§150(1): Setback,thermostat on all applicabie.heating and/or cooiing systems. §150(1): Pipe and Tank Insulation 1. Storage gas water heaters rated with an. Energy Factor less than 0.58 must be externally wrapped with insuiation'having an installed thermal, resistance of R-12 or greater. 2. First 5 feet of.pipas closest to water heater tank, non -recirculating systems, Insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other Indirect hot water tanks have. R-12 external insulation or R-16.combined intemal/extemal insulation. 4.:AII buried:orexposed piping insulated'in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F.; insulated. S. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft UsenNumber. 2655 Job Number. Page:7 of 17 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1R NOTE: :Lowrise residential buildings subject to the Standards must contaln, hese measures regardless of the compliance approach used. Items marked with an asterisk (') may, besuperseded by more stringent compliance requirements listed on the Certificate of Compliance., When this checklist is incorporated Into the permit documents;;the features noted shall be considered byall parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere inthe documents or on this checklist only. DESCRIPTION Instructions: -Check or initial applicable boxes.or enter NIA if. not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) I150(m): Ducts and Fans 1. All ducts and plenums Installed, sealed and insulated to meet.the requirements of the 1998 CMC Sections 601, 603,604 and Standard 6-3; ducts.insulated4o a minimum Instailed'Ievel of R-4.2 or enclosed entirely In conditionedspsoe. Openings.shall be sealed with mastic, tape, aerosol sealant; or other ductclosure system that meets the applicable requirements of UL' 181, UL181A, or UL181M If mastic or tape Is used to seal openings greater than 1/41Inch, the combination of.mastk: and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seems of duct systems and their, components shall not be sealed with doth back rubber adhesive duct tapes unless such tape Is used In combination with mastic and drawbands. 2. Bufiding cavities, support platforms for air handlers, and plenums defined or,construcfed with materials other than sealed sheet metal, duct board or flexible duct shall.not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in.the cross-sectional area of the ducts. 3.,Joints and seamsof duct systems and their components shall not be seated with cloth back rubber adhesive duct.tapes unless such a tape is used In oombination with mastic and drawbands. 4. Exhaustfan systems have back draft or automatic:dampers. 5. Gravity ventilation systems'serving•conditioned:space have e6erautomatic or readily accessible, manually operated dampers: 6. Protection of Insulation. Insulation shall be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and wind but not,ffmited'to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas; or plastic cover. Cellular foam Insulation shall be protected as above or painted with a coating that Is water retardant and provides'shielding from solar radiation that can cause degradation of the material. ❑ 114: Pool and Spa, Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating Instructions, no electric resistance heating, and no pilot. 2. System 1s installed with at least 36' of pipe between filter and heater for futuresolar, cover for outdoor pools, or spas., a. At:least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional Inlets and;a circulation pump timeswftch. JA I §115:. Gas fired centrel.fumaces, pool heaters, spa heaters or household cooking epplianoes have no continuously burning pilot 11ght (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet.specifled criteria Lighting .Measures ® §150(k)1:iLuminaires forgeneral lighting in kitchens shell have lampswith an efficacy 40 lumensAwatt or greater for general. lighting In kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting_ control panel at an.entrance to the kitchen. §150(k)2: Rooms with a shower.,'bathtub must have either at feast one luminaire with lamps with an efficacy of 40 Iumens1watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed In Section 150(k)2.; and recessed ceiling fixtures are IG(insulatlon cover) approved. Page:8 of 17 Computer Method Summary (Part 1 of 3) C -2R Cornet Residence 1/29/2004 Project Title Date Lot 102 - Eisenhower Drive —I a Qllinta Project Address Building Permit 0 Insu-form Inc. (760 324-2046 Documentatioh Author Telephone Plan CheckfDate omn 9t _r PerformancA 15 Field Check/Data Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 4.41 5.75 -1.34 Space Cooling 42.39 40.49 1.90 Domestic Hot water 9.52 10.08 -0.56 Totals 56:33 56.32 0.01 BUILDING C PL S GENERAL,INFORMATION X Slab Floor Conditioned Floor Area: 2,993 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: (Southwest) 225 deg Total Fenestration Area: 25.3% Number of Dwelling Units: 1.00 Total. ConditionedVolume: 29,930 Number of Stories: 1 Slab Floor Area: 2,993 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area 7nne 1 1% 14,940 0.50 Conditinned sethack 1 _n 7on . 2 1,499 14,990 0.50 Conditioned sethack Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Wall 223 0.059 225— 0 ❑ II 30 0.059 270 90 El El Wall 860_ 0.059 315 �90 wall 20 0.059 0 90 Wall�i 0 0.059 45_ _9Q ❑ Wall_ 638 0.059 135 _9D_ ❑ Roof 1.494 0.028 45 _ a Wall 237 0.059 225 .90 Wall 8a 0.059 315 n ❑ WAIT _ 460 0.059 4 �90 ❑ Wall S$9 0.059 135 _90 ❑ Roof 1.495 0.028 45 — a ^ ❑ 3 Reference Location / Comments 7nne 1 7nne 1 Done 1 7nna 1 7nne 1 ZonA I Zone 1 7nne 2 Zone 2 Zone 2 7nne 2 7nne 2 EnergyPro 3:1 By EnergySoft User Number. 2855 Job Number. Pane:9 of 17 1 Computer Method Summary (Part 2 of 3) C -2R Cornel, Residence 1/29/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Front (South -st) 30-0 0.650. n-36 225 2 Window Front (Southwest) 27.5 1.190 0.83 225 3 Window Front (Southwest) 37.5 1.190 0:83 225 4 Window Front (Southwest) 12.0 0:430 0.36 225 5 Window Front (Southwest) 16.0 0.430 0.36 225 6 Window. Front (Southwest) 64.0 0.430 0.36 2225 Z Window Front (Southwest) 48.0 0,550 0.40 225_ 8 Window Front (Southwest) 12:0 0.430 0.36 225 -9-- Window Front (Southwest) 9.0 0.430 0.36. 225 _M WiW nod yr Front .(Southwest) _20.0 0,550 0.40 225_ 11 Window Front (Southwest) 1:0 0,43 �0 6 225 12 Window Front (West) 15.0 0.650 0.36 270 Aa Window Front WAS4 4.5 0.430 0-36 270 14 Window Left (Northwest), 4.5 0.430 0.36 315 15 Window Left (Northwest) 15.0 0.650 0.36 315 16 Window Left (North) 15.0 0.650 0.36 0 17 Window Left (North) 4.5 0.430 0.36 0 18 Window Rear (Northeast) 15.0 0.650 0.36 45 18 Window Rear (Northeast) _ 4.5 0.430 0.36 45 20 Window Riaht (Southeast) 37.5 1.190 0.83 135 21' Window Right (Southeast) 20.0 1.190 0.83 135 22 Window Right (Southeast) 24.0 0:550 0.40 135 23 Window Front (Southwest) 11.0 1:190 0!83 225 24 Window Front (Southwest) 48.0 0.550 0.40 225 25 Window Front (Southwest) 12.0 0.430 0.36 225 26 Window Front (Southwest) 1.0 0.430 0:36 225' 27 Window Front (Southwest) 41.3 0.430 0.36 225 28 Window Left (Northwest) 22.5 1.190 0.83 315 29 Window Left (Northwest) 6.0 1.190_ 0.83 315 INTERIOR AND EXTERIOR SHADING ,,,r;,,,,,,,,., r QQ 90 90 90 90 90 - 90 90 90 - 90 90 90 on 90 90 90 90 90 so 90 90 0 90 90 90 90 90 90 90 Milgard Glazing Single Mtl Uncoated Default Single MtlUncoated'Default Milgard Glazing Milgard Glazing Milgard Glazing Milgard Glazing_ Milgard Glazing Milgard Glaiing Milgard Glazing_ Milgard Giaiing Milgard Glazing Miloard GlaAnGlaAng Milgard Glazing Milgard Glazing Milgard Glazing Milgard Glazina Milgard Glazing Milgard Glazing Sinale Mtl Uncoated Default Single Md Uncoated'Default Milgard:Glazing Single PAU Uncoated Default Milgard Glazing- M ilgard Glazing Milgard Glazing Milgard Glazing Single MU Uncoated Default Single Md Uncoated Default Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone1 Zone 1 Zone 1 Zone Zone' 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 1 Bug Screen 0.76 5.0 6:0 2.0 0.1 2:0 2.0 2 Bug Screen 0.76 5.0 5.5 2:0 0.1 2.0 2.0' 3 Bug Screen 0:76 7:5 5.0 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 1.5 4.0 12.0 0.1 12.0 12.0 5 Bug Screen 0.76 2.0 6:0 12.0 0.1 12.0 120 6 Bug Screen. 0.76 8:0 4.0 12.0 _Q 1 X2.0 �Z Il 7 Bug Screen 0.76 8:0 6.0 12.0 01 12.0 12.0 8 Bug Screen 0.76 2.0 6.0 12.0 0:1 12.0 12.0 9 Bug Screen 0.76 1.5 6:0 12.0 0:1 12.0 12.0 10 Bug Screen 0.76 8.0 2.5 12.0 0.1 12.0 12.0 11 Bug Screen 0.76 1.0 1.0 12.0 0.1 12.0 12.0 12 Bug Screen 0.76 5.0 3:0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 1.5 3:0 20 0.1 2.0 2.0 14 Bug Screen 0.76 1:5 3.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 5:0 3.0 2.0 0.1 2.0 2.0 16' Bug Screen 0.76 5.0 3.0 2.0 0:1 2.0 2.0 17 Bug Screen 0.76 1.5 3.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 5.0 3.0 4.0 0.1 4.0 4.0 19 Bug Screen 0.76 1.5 3.0 4.0 0.1 4.0 4.0 20 Bug Screen 0.76 7.5 5.0 28A 0.1 28.0 28.0 21 Bug Screen 0.76 5.0 4.0 2.00:1 2.0 2.0 22 'Bug Screen 0.76 8.0 3.0 28.0 0.1 28.0 28.0 23 Bug Screen 0.76 2.0 5.5 8.0 0.1 80 8.0 24 Bug Screen 0.76 8.0 6A 8.0 0.1 8:0 8.0 25 Bug Screen 0.76 2.0 6.0 8.0 0.1 8:0 8.0 26 Bug Screen 0.76. 1,0 1.0 2.0 0.1 2.0 2:0 27 Bug Screen 0.76 7.5 5.5 8.0 0.1 8.0 8.0 28 Bug Screen 0.76 7.5 3.0 28.0 0.1 28.0 28:0 29 Bug Screen 0.76 2.0 3:0 28A 0:1 28.0 28.0 3.1 By EnergySoft UsenNumber. 2655 Job Number. Page: 10 of 17 Computer Method Summary Window Hgt. Wd. Len. Overhang Hot. LEzt. (Part 2 of 3) C -2R 30 Bug:Screen 0.76 8:0 3.0 Cornel Residence 01 28.0 28:0 Ti Bug Screen 076 1/29/2004 Project Title 6.0 0:1 6.0' 6:0 , 32 Bug'Screen Date FENESTRATION SURFACES 2.0 6.0 0.1 6.0 6:0 33 Bug Screen 0.76 4:0 U= 6:0 Act. Glazing Type Location/ # Type Area. Factor SHGC Azm. Tilt Comments 30 Window Left Northwest) 24:0 0.550. 0.40- 315 ._9Q. Milaard Glazing Znne 2 31 Window Rear (Northeast) 48.0 0.550 0.40 45 90 Milgard Glazing Zone:2 32 Window Rear (Northeast) 6.7 0.430 0.36 , 45 90 Milgard Glazing Zone 2 33 Window Rear (Northeast) 10.7 0.430 0.36 46 90 Milgard Glazing Zone:2 34 Window Rear (Northeast) 25.0 0.650 0.36 45 90 Milgard'Glazing Zone 2 35 Window Right (Southeast) 11.1 0.430 0.36, 135 0 Milgard Glazing Zone 2 36 Window Right (Southeast) 30.0; 0:650 0.36 135 90 Milgard-Glazing Zone 2 37 Window Right (Southeast) 10.0 1:280 0.80 135 90 SingleNtl Uncoated Defauft Zone 2 _$ Window Right (outheast) _10.0 0.650 0.36 135 90I{dj(gani Glazrng Zone 2 .39 eight Rear(Northeast) 4.0 -0,440 OM 45 -0 Milgard Glazing Zone 2 INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Len. Overhang Hot. LEzt. Left Fin Right:Fin REA Dist. Len: Hgt. Dist. Len. Hgt: 30 Bug:Screen 0.76 8:0 3.0 28.0' 01 28.0 28:0 Ti Bug Screen 076 8.0 3:0 6.0 0:1 6.0' 6:0 , 32 Bug'Screen 0.76 3:4 2.0 6.0 0.1 6.0 6:0 33 Bug Screen 0.76 4:0 2.8 6:0 0.1 6.0 6:0 34 Bug Screen 0:76 35 Bug Screen 0.76 3.4 3':4 2.0 0. 7.0 __2:0 36 Bug Screen 0:76 6:0 5.0 2:0 0.1 2.0 2:0 37 Bug Screen 0.76 2.0 5.0 201 0.1 2:0 2.0 38 Bug Screen 0.76 2.0 5.0 -2'0 0:1 2.0 2.0 .39 None 1:00 Run Initiation Time: 01/2910414:42:11 _ Run Code: 1076416131 EnergyPro 3.1 By EnergySoft User Number. 2855, Job Number.: Page:11 of; 17 Computer Method Summary (Part 3 of 3) C -2R Corner Residence 1/29/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3' Reference' R -Val. Comments Concrete,He�yweig_ht !Ap _98 3"50 28 An/a. a Zone 1 /Slab on Grade Concrete Heavyweight 1,499 3.50 28 0.988 n1a 2 Zone 2 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter _ Q 0.76 0.0 0 Zone 1 Slab Perimeter 0. Zone 2 HVAC SYSTEMS Heating Equipment Type (furnace,. heat DUmD, etc.) Distribution Type. and Location Duct Thermostat Location ►(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Zone 1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Zone 2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling' Equipment Minimum Duct Type (air conditioner, Efficiency .Location Duct Thermostat Location./ heat pump, evap. cooling) (SEER) (attic, etc,), R -Value Type Comments Split Air Conditioner 12.0 SEE. Ducts inAttic .2. 4Setback Zone 'T Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone2 WATER HEATING -SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Neater 'Distribution # in: Input Cap. or Recovery Standby R -Value System Name Type Type 'Syst.. (Btu/hr) (gal) Efficiency Loss ('/o) Ext. A.O. SMITH FPS -50-224 Small Gas Standard 2_ 43,000 50 0.62 n/a n/a For small gas storage (rated input - 75000 Btuthr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (ratedAnput:> 75000 Btu/hr),.list Ratedinput,!Recovery Efficiency and Standby Loss. For instantaneous gas water..heaters,.list: Rated.lnput, and. Recovery Efficiency. Run Initiation Time: 01129/0414:42:11 Run Code: 1075416131 EneipyPio 3.1 B" Ene Sof User Number. 2655 Job,Number. Pa e:12of 17 Computer Method Summary (Addendum) C -2R Cornel Residence 1/29/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay specia[attention to the Items specified In this checklist. These Items requirespecial written` justification and documentation, and special verification to be used with the,perfonnance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of Owspecial justification and, documentation submitted: Plan Field HIGH MASS Design(see C-211) = Verify Thermal Mass: 1494 sgft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see.0-2R) - Verify Thermal Mass: 1499 sgft Covered Slab Floor, 3.50"'thick at Zone 2 HERS Required Verification These features mustbe confirmed and/or tested bya certified HERS rater under the -supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic. testing of these measures on.a form CF -6R. I Plan I Field The HVAC System "Zone 1" Includes Refrigerant Charge. and Airflow Credit (ora TXV). A certified HERS rater must:provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage perform by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 2" includes Refrigerant Charge. and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run n`ti ti 04 14@4 2:11 Run Code: 107641613 Energypro 3.1 By EnergySoft User Number. 2855 Job Number. Page:13 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Cornet Residence 1/29/2004 SYSTEM NAME FLOOR AREA .Zone 1 1.494 Total Output (sgftrron) 1, 309.11 AWS stem CFM per System 2,055 Airflow (cfm) 2,055 Airflow (cfrn/sgft) 1.38 Airflow (cf ffon) 425.2 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of Outside Air 0 ctm 69M of 1'.0/77AOF Outs 0 cirri 78.8/67.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK. I COIL HTG. PEAK CFM I Sensiblel -Latent I CFM I Sensible 2,210 35,464 3,562 1,229 45,131 0 1,773 2,257 0 0 0 0 0 0 0 0 0 1,773 2,257 39,01 1 49 644 BDP CO.563AN060-A 36,516 17,098 86,000 Total Adjusted System Output 36,516 17;098 80;000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 2 pm 1 Jan 12 am 69.0 of 69A of . 105.3 OF 0 Supply Fan Heating Coil 2055 cfm h Retum Air Ducts M 78.8167.1 OF . 78.8 / 67.1oF M62.2/'61.20F Supply Fan Cooling Coil 2055 cfm >% Retum Air Ducts `i Supply Air Ducts 104.3 of ROOMS 70._0 of Supply Air Ducts 63,0 / 61.4 of 56.4% R.H. ROOMS 78.0 f666.9 of I Energy 3.1 By EnergySoft User Number. 2655 Job Number. Page:14 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Cornel Residence 1/29/2004 SYSTEM NAME FLOOR AREA Zone 2 1 499 NGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Stuh/sgft) 53.4 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 38.7 Total Output (sqftrron) 310.1 Air System CFM per System 2,055 Airflow (cfm) 2,055 Airflow (cfm/sgft) 1.37 Airflow (cimITon) 425.2 Outside Air (%) 0.0 Outside Air (cfm/sgfi) 0.00 Note: values (EATING S' 26.0 of Outside Air 0 Cfm 69.3 OF 11.0 /77.4 of 0 Outside 0 cfm 78.7/67.1OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,99 32,197 3;574 774 29,039 0 1,610 1,452 0, 0 0 0 0 0 0 0 0 1,610 1,452 35,41 3574 31,942 BDP CO.563AN0%A 36,450 17,126 80,000 Total,Adjusted System Output 36,450 17,128 80,000 (Adjusted for Peak Design Conditlons) TIME OF SYSTEM PEAKF77 Aug 2 pm I Jan 12.am 69.3 OF 69.3 OF 105.7 OF Supply Fan Heating Coil 2055 cfm h Return Air Ducts M 78.7 / 67.1 of 78.7/67.10F M 62.2/61.10P Supply Fan Cooling Coil 2055 cfm h Return Air Ducts `S Suppiy Air Ducts 105.0 of ROOMS 70.0 of Supply Air Ducts 62.9161.4 of 56:3% R.H.. ROOMS 78.0/66.8 OF EnergyPro 3.1 BylEnergySoft User Number. 2655 Job Number. Page: 15 of 17 ROOM LOAD SUMMARY PROJECT NAME Cornel Residence DATE 1/29[2004 SYSTEM NAME Zone 1 FLOOR AREA 1,494 FRO -OM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME MuR. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 2,210 35,464 3,562 2,210 35;464, 3,562 1,229 45,131 PAGE TOTAL - 2,210 35,464 3,562 1,229 45,131 TOTAL 1 2,210 35,464 3,562 1,229 45,131 Job Number: Page: 16 of 17 ROOM LOAD SUMMARY PROJECT NAME Cornel Residence DATE. 1/29/2004 SYSTEM NAME Zone 2 FLOOR AREA 1: 499 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Muft. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 1,991 32,197 3,574 1,991 32197 3,574 774' 29,039 PAGE TOTAL 1 1,991 32,197 3,574 774 29;039 TOTAL 1 1,991 32,197 3;574 774 297039 EnergyPro 3.1 By. EnergySoft User Number. 2655 Job Number. Page: 17 of 1,7