BRES2018-0165 Title 24I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Custom Residence Lot 181 Hideaway La Quinta, CA 92253 Project Designer: Stracts, Inc 550 S. Oleander Palm Springs„ CA 92264 (760) 636-8951 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc, 74818 Velie Way Suite 8 Palm Desert, CA 92260 (760) 200-4780 c5ptCC= TY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE ❑ATE 1kp\U% BYL RECEIVE--% Job Number: JUL 19 2018 CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 6/27/2018 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standard This program developed by EnergySoft Software —www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 18 Form MF-1 R Mandatory Measures Summary 20 HVAC System Heating and Cooling Loads Summary 24 Zone Load Summary 28 Room Load Summary 32 Room Heating Peak Loads 36 Room Cooling Peak Loads 40 EnergyPro 7.2 by EnergySoft Job Number: ID: User Number: 6712 _ 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CFI R-PRF-01 Page I of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml GENERAL INFORMATION 01 Project Name Lot 181 Hideaway 02 Calculation Description Title 24 Analysis 03 Project Location Lot 181 Hideaway 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 135 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 5503 15 Number of Zones 4 16 Slab Area (ft) 4316 17 Number of Stories 2 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 27.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.22 6.07 -1.85 -43.8% Space Cooling 92.79 82.65 1014 10.9% IAQ Ventilation 077 0.77 000 0.0% Water Heating 259 696 -4.37 -168.7% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 100.37 96.45 3.92 3.9% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml CF1 R-PRF-01 Page 2 of 15 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 48.4 46.8 0.0 46.8 El Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Floor has high level of insulation • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • Pipe Insulation, All Lines Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 - Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 3 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 181 Hideaway 5503 1 4 4 0 1 ZONE INFORMATION 01 02 03 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg, Ceiling Height Water Heating System 1 Water Heating System 2 Master Suite Conditioned HVAC-Master 4T1 1772 11.8 DHW Sys 1 n/a great/kitchen Conditioned HVAC great 2-5 T2 2064 10.6 DHW Sys 1 n/a service dining Conditioned HVAC-service 3T3 480 11 8 DHW Sys 1 n/a Second Floor Zone Conditioned HVAC-2nd Fir 5T4 1187 9 DHW Sys 1 n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CFI R-PRF-01 Page 4 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall Master Suite R-21 Wall 0 specify - 588 52 90 E Wall Master Suite R-21 Wall 90 - specify - 426 45 90 S Wall Master Suite R-21 Wall 180 specify - 924 211 90 W Wall Master Suite R-21 Wall 270 - specify - 426 42 90 Interior Surface Master Suite»great/kitchen R-0 Interior Surface n/a n/a 500 0 n/a Roof 2 Master Suite R-38 Roof Attic R19 High n/a n/a 1772 n/a n/a N Wall 2 great/kitchen R-21 Wall 0 - specify - 466 6 90 NE Wall great/kitchen R-21 Wall 45 Right 388 81.5 90 E Wall 2 great/kitchen R-21 Wall 90 - specify - 196 15 90 SE Wall great/kitchen R-21 Wall 135 Front 420 59.4 90 S Wall 2 great/kitchen R-21 Wall 180 - specify - 103 0 90 SW Wall great/kitchen R-21 Wall 225 Left 96 0 90 W Wall 2 great/kitchen R-21 Wall 270 specify - 966 593 90 Interior Surface 2 great/kitchen»service dining R-0 Interior Surface n/a n/a 500 0 n/a Roof 3 great/kitchen R-38 Roof Attic R19 High n/a n/a 2064 n/a n/a NE Wall 2 service dining R-21 Wall 45 Right 380 22 90 SE Wall 2 service dining R-21 Wall 135 Front 260 76.5 90 SW Wall 2 service dining R-21 Wall 225 Left 260 60.3 90 NW Wall service dining R-21 Wall 315 Back 96 0 90 Interior Surface 3 service dining»Second Floor Zone R-0 Interior Surface n/a n/a 480 0 n/a N Wall 3 Second Floor Zone R-21 Wall 0 - specify - 196 10 90 NE Wall 3 Second Floor Zone R-21 Wall 45 Right 960 69.5 90 SE Wall 3 Second Floor Zone R-21 Wall 135 Front 196 6 90 SW Wall 3 Second Floor Zone R-21 Wall 225 Left 820 40 90 W Wall 3 Second Floor Zone R-21 Wall 270 - specify - 380 96 90 NW Wall 2 Second Floor Zone R-21 Wall 315 Back 96 0 90 Interior Surface 4 Second Floor Zone»Master Suite R-0 Interior Surface n/a n/a 255 0 n/a Roof 4 Second Floor Zone R-38 Roof Attic R19 High n/a n/a 1187 n/a n/a Raised Floor Second Floor Zone R30 W/O CRAWLSPACE n/a n/a 822 n/a n/a Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 5 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof service dining R30 - specify - 480 0 1 0.1 0.85 No ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Suite Attic RoofMaster Suite Ventilated 3 0.61 0.86 Yes Yes Attic great/kitchen Attic Roofgreat/kitchen Ventilated 0.61 0.86 Yes Yes Attic Second Floor Zone Attic RoofSecond Floor Zone Ventilated 3 0.61 0.86 Yes Yes Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 6 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading 15 Window N Wall (- specify --0) 1 40.0 0.39 0.27 Insect Screen (default) AM Window N Wall (- specify --0) - - 1 3.0 0.30 0.20 Insect Screen (default) AL Window N Wall (- specify --0) -- --- 1 3.0 0.30 0.20 Insect Screen (default) AK Window N Wall (- specify --0) 1 3.0 0.30 0.20 Insect Screen (default) AJ Window N Wall (- specify --0) ---- 1 3.0 0.30 0.20 Insect Screen (default) AN Window E Wall (- specify --90) 1 3-0 0.30 0.20 Insect Screen (default) AH Window E Wall (- specify --90) 1 3.0 0.30 0.20 Insect Screen (default) AG Window E Wall ( specify --90) - 1 3.0 0.30 0.20 Insect Screen (default) RR Window E Wall (- specify --90) -- --- 1 3.0 0.30 0.20 Insect Screen (default) QQ Window E Wall (- specify --90) -- 1 3.0 0.30 0.20 Insect Screen (default) PP Window E Wall (- specify --90) - --- 1 3.0 0.30 0.20 Insect Screen (default) NN Window E Wall ( specify --90) - 1 3.0 0.30 0.20 Insect Screen (default) MM Window E Wall (- specify -90) - 1 3.0 0.30 0.20 Insect Screen (default) LL Window E Wall (- specify -90) - - 1 3.0 0.30 0.20 Insect Screen (default) KK Window E Wall (- specify --90) - - -- 1 3.0 0.30 0.20 Insect Screen (default) AF Window E Wall (- specify --90) - 1 3.0 0.30 0.20 Insect Screen (default) AE Window E Wall (- specify --90) -- 1 3.0 0.30 0.20 Insect Screen (default) AD Window E Wall (- specify --90) ---- 1 3.0 0.30 0.20 Insect Screen (default) AC Window E Wall (- specify --90) 1 3.0 0.30 0.20 Insect Screen (default) AB Window E Wall (- specify --90) ---- - - 1 3.0 0.30 0.20 Insect Screen (default) AU Window S Wall (- specify --180) ---- 1 6.0 0.30 0.20 Insect Screen (default) ZZ Window S Wall (- specify --180) -- - 1 42.0 0.30 0.20 Insect Screen (default) 14 Window S Wall (- specify --180) ---- -- 1 104.0 0.39 0.27 Insect Screen (default) AA Window S Wall (- specify --180) - 1 17.5 0.30 0.20 Insect Screen (default) Z Window' S Wall (- specify --180) ---- 1 17.5 0.30 0.20 Insect Screen (default) JJ Window S Wall (- specify --180) ---- --- 1 3.0 0.30 0.20 Insect Screen (default) HH Window S Wall (- specify --180) - - - 1 30 0.30 0.20 Insect Screen (default) GG Window S Wall (- specify --180) --- --- 1 3.0 0.30 0.20 Insect Screen (default) FFF Window S Wall (- specify --180) --- 1 3.0 0.30 0.20 Insect Screen (default) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml CF1 R-PRF-01 Page 7 of 15 EE Window S Wall (- specify --180) ---- 1 3.0 0.30 1 0.20 Insect Screen (default) DD Window S Wall (- specify --180) --- 1 3.0 0.30 0.20 Insect Screen (default) CC Window S Wall (- specify --180) - 1 3.0 0.30 020 Insect Screen (default) BB Window S Wall (- specify --180) ---- ---- 1 3.0 0.30 0.20 Insect Screen (default) SS Window W Wall (- specify --270) 1 3.0 0.30 0.20 Insect Screen (default) TT Window W Wall (- specify --270) 1 3.0 0.30 0.20 Insect Screen (default) UU Window W Wall (- specify --270) - --- 1 3.0 0.30 0.20 Insect Screen (default) VV Window W Wall (- specify --270) - 1 3.0 0.30 0.20 Insect Screen (default) WW Window W Wall (- specify --270) ---- .--- 1 3.0 0.30 0.20 Insect Screen (default) XX Window W Wall (- specify --270) - 1 3.0 0.30 0.20 Insect Screen (default) YY Window W Wall (- specify --270) ---- 1 3.0 0.30 0.20 Insect Screen (default) S Window W Wall (- specify --270) ---- 1 3.0 0.30 0.20 Insect Screen (default) T Window W Wall (- specify --270) - 1 3.0 0.30 0.20 Insect Screen (default) U Window W Wall (- specify --270) -- 1 3.0 0.30 0.20 Insect Screen (default) V Window W Wall (- specify --270) ---- ---- 1 3.0 0.30 0.20 Insect Screen (default) W Window W Wall (- specify --270) - 1 3.0 0.30 0.20 Insect Screen (default) X Window W Wall (- specify --270) --- - 1 30 0.30 0.20 Insect Screen (default) Y Window W Wall (- specify --270) - --- 1 3.0 0.30 0.20 Insect Screen (default) M Window N Wall 2 (- specify --0) --- -- 1 6.0 0.30 0.20 Insect Screen (default) K Window NE Wall (Right-45) - -- 1 12.0 0.30 0.20 Insect Screen (default) 7 Window NE Wall (Right-45) - 1 20.0 0.39 0.27 Insect Screen (default) J Window NE Wall (Right-45) - --- 1 12.0 0.30 0.20 Insect Screen (default) H Window NE Wall (Right-45) ---- - 1 37.5 0.30 0.20 Insect Screen (default) AT Window E Wall 2 (- specify --90) -- 1 3.0 0.30 0.20 Insect Screen (default) AT 2 Window E Wall 2 (- specify --90) - - 1 3.0 0.30 0.20 Insect Screen (default) AT 3 Window E Wall 2 (- specify --90) - 1 3.0 0.30 020 Insect Screen (default) AT 4 Window E Wall 2 (- specify --90) - -- 1 3.0 0.30 0.20 Insect Screen (default) AT 5 Window E Wall 2 (- specify --90) 1 3.0 0.30 0.20 Insect Screen (default) B Window' SE Wall (Front-135) - 1 11.7 0.30 0.20 Insect Screen (default) 1 Window SE Wall (Front-135) - -- 1 36.0 0.39 0.27 Insect Screen (default) A Window SE Wall (Front-135) ---- ---- 1 11.7 0.30 0.20 Insect Screen (default) 11 Window W Wall 2 (- specify --270) 23.0 10.0 1 230.0 0.39 0.27 Insect Screen (default) R Window W Wall 2 (- specify --270) 30 3.0 1 9 0 0.30 0.20 1 Insect Screen (default) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 8 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml Q Window W Wall 2 (- specify --270) 3.0 3.0 1 9.0 0.30 0.20 Insect Screen (default) P Window W Wall 2 (- specify --270) 3.0 3.0 1 9.0 0.30 0.20 Insect Screen (default) N Window W Wall 2 (- specify --270) 3.0 3.0 1 9.0 0.30 0.20 Insect Screen (default) 10 Window W Wall 2 (- specify --270) 4.5 8.0 1 36.0 0.39 0.27 Insect Screen (default) 9 Window W Wall 2 (- specify --270) 7.5 8.0 1 60.0 0.30 0.20 Insect Screen (default) 8 Window W Wall 2 (- specify --270) 2.5 8.0 1 20.0 0.30 0.20 Insect Screen (default) L Window W Wall 2 (- specify --270) 2.0 3.0 1 6.0 0.30 0.20 Insect Screen (default) 23 Window W Wall 2 (- specify --270) 2.5 8.0 1 20.0 0.39 0.27 Insect Screen (default) 13 Window W Wall 2 (- specify --270) 11.7 10.0 1 117.0 0.39 0.27 Insect Screen (default) 12 Window W Wall 2 (- specify --270) 8.5 8.0 1 68.0 0.39 0.27 Insect Screen (default) G Window NE Wall 2 (Right-45) ---- --- 1 6.0 0.30 0.20 Insect Screen (default) F Window NE Wall 2 (Right-45) 1 16.0 0.30 0.20 Insect Screen (default) 2 Window SE Wall 2 (Front-135) 1 76.5 0.39 0.27 Insect Screen (default) C Window SW Wall 2 (Left-225) 1 60.3 0.30 0.20 Insect Screen (default) BD Window N Wall 3 (- specify --0) ---- ---- 1 10.0 0.30 0.20 Insect Screen (default) BC Window NE Wall 3 (Right-45) ---- -- 1 10.0 0.30 0.20 Insect Screen (default) BA Window NE Wall 3 (Right-45) ---- 1 6.0 0.30 0.20 Insect Screen (default) AZ Window NE Wall 3 (Right-45) - 1 25.0 0.30 0.20 Insect Screen (default) AY Window NE Wall 3.(Right-45) 1 6.0 0.30 0.20 Insect Screen (default) AX Window NE Wall 3 (Right-45) - - 1 7.5 0.30 0.20 Insect Screen (default) AW Window NE Wall 3 (Right-45) -- -- 1 15.0 0.30 0.20 Insect Screen (default) AV Window SE Wall 3 (Front-135) - -- 1 6.0 0.30 0.20 Insect Screen (default) BJ Window SW Wall 3 (Left-225) - 1 8.0 0.30 0.20 Insect Screen (default) BH Window SW Wall 3 (Left-225) --•- - - 1 8.0 0.30 0.20 Insect Screen (default) BG Window SW Wall 3 (Left-225) ---- - 1 8.0 0.30 0.20 Insect Screen (default) BF Window SW Wall 3 (Left-225) ---- ---- 1 8.0 0.30 0.20 Insect Screen (default) BE Window SW Wall 3 (Left-225) 1 8.0 0.30 0.20 Insect Screen (default) 30 Window W Wall 3 (- specify --270) 1 96.0 0.39 0.27 Insect Screen (default) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Lot 181 Hideaway Calculation Description: Title 24 Analysis Calculation Date/Time: 08:50, Wed, Jun 27, 2018 Input File Name: tmpDF69.tmp.xml Page 9 of 15 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 11 18 0.1 18 18 0 0 0 0 0 0 0 0 0 R 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Q 8 0.1 8 8 0 0 0 0 0 0 0 0 0 P 8 01 8 8 0 0 0 0 0 0 0 0 0 N 8 0.1 8 8 0 0 0 0 0 0 0 0 0 10 10 01 10 10 0 0 0 0 0 0 0 0 0 9 16 0.1 16 16 0 0 0 0 0 0 0 0 0 8 16 0.1 16 16 0 0 0 0 0 0 0 0 0 L 8 0.1 8 8 0 0 0 0 0 0 0 0 0 23 8 0.1 8 8 0 0 0 0 0 0 0 0 0 13 16 0.1 16 16 0 0 0 0 0 0 0 0 0 12 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation DatefTime: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 10 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Suite Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic R19 High attic) Wood Framed Ceiling 2x4 @ 16 in. O.C: R 38 0.025 Over Ceiling Joists: R-28 9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 R-0 Interior Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgreat/kitchen Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-30/2x10 • Roof Deck: Wood Siding/sheathing/decking R30 Cathedral Ceilings Wood Framed Ceiling 2xl0 @ 16 in O.C. R 30 0 037 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofSecond Floor Zone Attic Roofs Wood Framed Ceiling in O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking R30 W/O CRAWLSPACE Exterior Floors Wood Framed Floor 2x6 @ 16 in. 0 C. R 30 0.037 Cavity/Frame: R-30/2x6 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value 8• Depth Carpeted Fraction Heated Slab -on -Grade Master Suite 1772 120 None 0.8 No Slab -on -Grade 2 great/kitchen 2064 190 None 0.8 No Slab -on -Grade 3 service dining 480 120 None 0.8 No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 11 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW (HERS req'd) Pipe Insulation, All Lines DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Large Storage 1 100 0.8 frac 85,000 Btu/hr R-0/R-0 0.03 n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 Pipe Insulation, All Lines n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 62 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC-Master 4T1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC great 2-5 T2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC-service 3T3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC-2nd Flr 5T4 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 12 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 2 80 AFUE Heating Component 3 CntrlFurnace 1 80 AFUE Heating Component 4 CntrlFurnace 1 80 AFUE HVAC -COOLING UNIT TYPES 01 02 03 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 2 12.7 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 4-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Registration Number: Registration DatefTlime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 13 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 2-hers-dist Air Distribution System 3 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 3-hers-dist Air Distribution System 4 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 4-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.56 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.56 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.56 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.56 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.56 HVAC Fan 2-hers-fan Required 0.56 HVAC Fan 3-hers4an Required 0.56 HVAC Fan 4-hers-fan Required 0.56 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Page 14 of 15 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 93 0.25 Default 0 Required Registration Number: Registration DatefTime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: tmpDF69.tmp.xml Page 15 of 15 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon d. Scott Company: Signature Date: Scott Deign and Title 24, Inc, 6/27/2018 Address: 74818 VeIie Way Suite 8 CEA/HERS Certification Identification (If applicable): City/Statei[Zip:r Desert, CA 92260 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application Responsible Desier Name: Anton 1Parinkavich Responsible Designer Signature: Company: StraciS, Inc Date Signed: Address: 550 S. Oleander License: City/StateMp: Palm Springs„ CA 92264 Phone: (760) 636-8951 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 612712018 Project Address Lot 181 Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,503 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 38 5,023 Add=R-19.0 Cool Roof New Wall Wood Framed Slab Unheated Slab -on -Grade R 21 7,158 - no insulation 4,316 Perim = 430' New New Demising Wood Framed - no insulation 1,735 New Roof Wood Framed Rafter R 30 480 New Floor Wood Framed w/o Crawl Space R 30 822 New FENESTRATION Orientation Area fe Total Area: 1,485 Glazing Percentage: 27.0% New/Altered Average U-Factor: U-Fac SHGC Overhang Sidefins Exterior Shades 0.35 Status Rear (N) 40.0 0.390 0.27 none none Bug Screen New Rear (N) 28.0 0.300 0.20 none none Bug Screen New Right (E) 60.0 0.300 0.20 none none Bug Screen New Front (S) 107.0 0.300 0.20 none none Bug Screen New Front (S) 104.0 0.390 0.27 none none Bug Screen New Left (W) 42.0 0.300 0.20 none none Bug Screen New Right (NE) 153.0 0.300 0.20 none none Bug Screen New Right (NE) 20.0 0.390 0.27 none none Bug Screen New Front (SE) 2R4 0.300 0.20 none none Bug Screen New Front (SE) 112.5 0.390 a27 none none Bug Screen New Left (W) 230.0 0.390 0.27 18.0 none Bug Screen New Left (Kq 42.0 0.300 0.20 8.0 none Bug Screen New Left (lM 104.0 0.390 0.27 10.0 none Bug Screen New Left (lM 80.0 0.300 0.20 16.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16, 0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC-Master 4T Ducted Ducted Attic 8.0 New HVAC great 2-5 T Ducted Ducted Attic 8.0 New HVAC-service 3T Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Large Storage Gas 100 0.80 All Pipes Ins (HERS) New EnergyPro 7.2 by EnerovSoft User Number: 6712 ID: Page 18 of 51 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2018 Project Address Lot 181 Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,503 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION I Total Area: 1,485 Glazing Percentage- 27.0% New/Altered Average U-Factor: Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades 0.35 Status Left (140 20.0 0.390 0.27 8.0 none Bug Screen New Left (W 117.0 0.390 0.27 16.0 none Bug Screen New Left (SWJ 100.3 0.300 0.20 none none Bug Screen New Left (lM 96.0 0.390 0.27 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC-2nd Flr 5T Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener vPro 7.2 by Enera Soft User Number: 6712 ID- Pa e 19 of 51 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (0rininA W On16) Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/l.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.E-A and 110,6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R. § 110.8(j): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average 1-1-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceilin .' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(0: Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 permlinch; be protected from physical damage and UV light deterioration; and, when installed as art of a heated slab floor, meet the requirements of § 110.8 . Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to 150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation, 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is hi her than the cut-off temperature for supplementary heatin .' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment L150. (h)I Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using desi ri conditions specified in 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any d er vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve." § 150.0(j)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A• Distribution piping for steam and hydronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5• § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corooration (SRCC) or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11; occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)l 1 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)l 2. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return § 150.0(m)13: grilles, and an air -handling unit fan efficacy 5 0,58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic § 150.0(o)1A: testin , in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater § 110.4(a): without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated § 110.4(b)1: suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2; Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that § 110.4(b)3: will allow all pum2s to be set or programmed to run only during off- eak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow 150.0 § (p)' rate. piping, fillers, and valves.' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements § 110.9: of & 110.9.' JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must § 110.9(e): be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan sp2ed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 Ct labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than § 150.0(k)1 D: 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled b vacancy sensors. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) § 150.0(k)1 F: must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with'JA8-2016' or "JA8-2016-E' as specified in Reference Joint Appendix JA8' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with'JA8-2016-E.' § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually § 150.0(k)2C: switched ON and OFF, § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions, Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k)2E: § 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other re uirements in § 150.0k Z Interior Switches and Controls, An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0k 2. Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it § 150.0(k)21: provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. A nft, JL 2016 Low -Rise Residential Mandato Measures Summary § 150.0(1k)2S Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallwa ' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3AN (photo control and automatic time switch control, astronomical time clock, or Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 150.0 k 3A or with the applicable requirements in 110.9.130.0,130.2,130.4 1401 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or§ 150.0(k)30 mustcomply with the applicable r uirements in 110.9, 130.0,130.2. 130,4,140,7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must com I with the a licable requirements in 110.9, 130.0.130.2,13044 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garNes in iq 110.9, 130A 130.1, 130.4, 140.6. and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be hl h efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0, 130.1, 140.E and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percenil. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the r29 uirements of § 110.10 b throu h' 110.10 e § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110,10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area: § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zm measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly Indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel): and a Whway for roufin2 of plumbing from the solar zone to the water -heating s stem. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 1 10.10c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit locabon; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence System Name HVAC-Master 4T ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK Heating System CFM Sensible Latent Output per System 61,000 Total Room Loads Total Output Btuh) 61,000 Return Vented Lighting Output (Btuh/sgft) 34.4 Return Air Ducts Cooling System Return Fan Output perSystem 49,000 Ventilation 9881 20,4321 2,707 0 Total Output (Btuh) 49,000 Supply Fan 4 Total Output (Tons) 4•1 Supply Air Ducts C Total Output (Btuh/sqft) 27.7 Total Output (sgft/Ton) 434.0 TOTAL SYSTEM LOAD Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow(cfm) 1,600 Carrier 24ANB748-58CVX080 Airflow (cfmis ft) 0.90 Airflow (cfm/Ton) 391.8 Outside Air (%) 0.0% Total Adjusted System Output 0.00 (Adjusted for Peak Design conditions) Outside Air (cfm/s ft) Note: values above given at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Pea 70 OF 105 °[ 105 OF M • Outside Air llllll -4 0 cfm V- Heating Coil Supply Fan 1,600 cfm 0 0 0 963 22,358 2,707 36,5601 5,056 36.5601 5, Aug 3 Date 6/27/2018 Floor Area 1,772 COIL HTG. PEAK CFM Sensible 5931 21,787 23,451 61,000 1 61,0001 Jan 1 105 OF ROOD 70 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112 l 78 OF 76 l 62 OF 55 / 54 OF 55 l 54 °F Outside Air _ 0 Supply Fan 56154 °F cfm Cooling Coil 1,600 cfm 48.1% ROOM 76,162 °F 751 62 °F 7.2 by EnergySoft User Number 6712 ID: Page 24 of 51 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence System Name HVAC great 2-5 T ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 1.1 Output per System 89,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Total Output Btuh) 178,000 Out ut Bft tuh1s 86.2 CoolingSystem Output per System 57,500 Total Output Btuh 115,000 Total Output (Tons) 9.6 Total Output Stuh/s ft 55.7 at Total Outn,ISrifflronl 215.4 Air Svstem Date 6/27/2018 Floor Area 2,064 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,397 29,247 3,153 855 31,583 0 1,378 1.206 0 0 0 0 0 0 179 1,378 32,182 3,153 -179 1,206 33,815 CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm 4,000 Carrier 24ANB760/58PH"'110 85,508 11,576 178,000 Airflow (cfmis ft) 1.94 Airflow (cfm/Ton 41T4 Outside Air p•0% Total Adjusted System Output 85,5081 11,576 178,000 (Adjusted for Peak Design conditions) 0.00 Outside Air (cfmisgft) Note: values above given at ARI conditions TIME OF SYSTEM PEAK 1 Aug 3 PM Jan 1 HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 70 OF 105 IF 105 OF I- I. Outside Air t 0 cfm Heating Coil Supply Fan 105 °F 4,000 cfm ROOM COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112 / 78 OF 75 162 OF 55 / 54 OF 55154 °F Outside Air Supply Fan 0 cfm Cooling Coil 4,000 cfm 47.0% 70 OF 55 / 54 OF ROOM 5/6l 7.2 by EnergySoR User Number 6712 ID: Page 25 of 51 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Custom Residence 6/27/2018 Floor Area System Name HVAC-service 3T 480 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Total Room Loads 399 Return Vented Lighting Return Air Ducts Return Fan Ventilation i 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Sensible Latent CFM 8,357 733 298 0 394 0 0 0 0 0 394 F 9,145 733 Sensible Output per System 51,000 10,983 Total Output Btuh 51,000 Output (Btuh/sgft) 106.3 419 Cooling System 0 Output per System 36,000 0 Total Output (Btuh) 36,000 0 Total Output Tons 3.0 419 Total Output (Btuh/s ft) 75.0 Total Output (s ft/Ton 160.0 11,822 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 Carrier 24ANB736/58PH**070 26,373 3,980 51,000 Airflow (cfm/sqft) 2.50 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 26,373 3,980 51,000 0.00 Outside Air (cfm/sgft) TIME OF SYSTEM PEAK Aug 3 PUIJan 1 AM Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 105 OF 105 IF Outside Air 0 cfm Heating Coil Supply Fan ° 105 F 1,200 cfm ROOM 70 °F COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 1112/78OF 75 162 OF 55 / 54 OF 55154 OF 10 Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF AL 1,200 cfm 46.8% ROOM 75 162 OF 75 ! 62 OF n I tl f EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 26 of 51 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence Date 6/27/2018 System Name HVAC-2nd Fir 5T Floor Area 1,187 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 860 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 17,945 1,813 442 16,340 Total Output (Btuh) 89,000 0 Output Btuh/s ft 75.0 846 624 Cooling System 0 0 Output per System 57,500 0 0 0 0 Total Output (Btuh) 57,500 89 1,813 -89 Total Output Tons 4•8 846 624 Total Output (Btuh/sgft) 48.4 Total Output (s ft[Ton 247-7 19,726 17,499 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Carrier 24ANB760/58PH""110 42,769 5,822 89,000 Airflow (cfm/s ft) 1.68 Airflow (cfm/Ton) 417.4 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 42,769 5,822 89,000 Aug 3 PM Jan 1 AM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) —0-0- 1p Outside Air 0 cfm 70 IF 105 OF 105 OF S Heating Coil Supply Fan 2,000 cfm ROOM �^ 70 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112 /78OF Outside Air 0 cfm AL 14 Cooling Coil Supply Fan; 2,000 cfm 54 47.2% ROOM EnergyPro 7.2 by EnergySoff User Number: 6712 /D: Page 27 of 5l ZONE LOAD SUMMARY Project Name Custom Residence Date 6/27/2018 System Name HVAC-Master 4T Floor Area 1,772 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Master Suite 1.0 0 Aug 3 PM 988 20,432 2,707 593 21,787 TOTALS 0 0 0 0 Aug 3 PM 20,432 2,707 21,787 (BLOCK LOAD) EnergyPro 7.2 by EnergySvR User Number: 6712 10. Page 28 of 51 ZONE LOAD SUMMARY Project Name Custom Residence Date 6/27/2018 System Name HVAC great 2-5 T Floor Area 2,064 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible I Latent CFM Sensible great/kitchen 1.0 0 Aug 3 PM 1,397 29,2471 3,153 855 31,583 TOTALS 0 0 0 0 Aug 3 PM 29,247 3,153 31,583 BLOCK LOAD) EnergyPro 7.2 by EnergySa t User Number 6712 ID: Page 29 of 51 ZONE LOAD SUMMARY Project Name Custom Residence System Name HVAC-service 3T Date 6/27/2018 Floor Area 480 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible service dining 1.0 0 Aug 3 PM 399 8,357 733 298 10,983 TOTALS 0 0 0 0 Aug 3 PM 8,357 733 10,983 BLOCK LOAD) EnergyPro 7.2 by FnergySoR User Number.' 6712 ID: Page 30 of 51 ZONE LOAD SUMMARY Project Name Custom Residence Date 6/27/2018 System Name HVAC-2nd Fir 5T Floor Area 1,187 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Second Floor Zone 1.0 0 Aug 3 PM 660 17,945 1,813 442 16,340 TOTALS 0 0 01 01 Aug 3 PM 1 17,945 1,813 16,340 (BLOCK LOAD Er�ergyPro 7.2 by EnergyScR User Number: 6712 la: Page 37 of 51 ROOM LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 System Name Floor Area HVAC-Master 4T 1,772 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite I Master 1 1 9881 20, 432 2,7079 9881 20,4321 2, 707 593 21, 787 PAGE TOTAL TOTAL* 988 20,4321 2,7071 593 21,787 988 20,432 2,707 593 21,787 Total includes ventilation load for zonal systems. EnergyPro 7.2 by EneravSoft User Number., 6712 ID: Page 32 of 51 ROOM LOAD SUMMARY Project Name Custom Residence System Name HVAC great 2-5 T ROOM LOAD SUMMARY ROOM COOLING PEAK Zone Name Room Name Mult. CFM I Sensible I Latent great/kitchen Great living Area 1 1.397 29,247 3,153 PAGE TOTAL TOTAL " Date 612712018 Floor Area 2,064 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,3971 29,2471 3,153 855 31, 583 1,3971 29,247 3,153 855 31,583 1.397 29,247 3,153 855 31,583 Total includes ventilation load for zonal s ster EneravPro 7.2 kv Energv5oft User Number. 33 of 51 ROOM LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 System Name Floor Area HVAC-service 3T 480 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. I CFM Sensible I Latent CFM Sensible Latent CFM Sensible service dining dining 1 399 8,3571 733 399 8,3571 733 298 10, 983 PAGE TOTAL TOTAL'` 399 8.357 7331 2981 10,983 3991 8,357 7331 2981 10,983 " Total includes ventilation load for zonal systems. EneryvPro 7.2 by EneravSoft User Number: 6712 ID: Page 34 of 51 ROOM LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 System Name Floor Area HVAC-2nd Flr 5T 1.187 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible Second Floor Zone Second Floor 1 860 17,945 1,813 860 17,945 1,813 442 16,340 PAGE TOTAL 860 17,945 1,1113 4421 16,340 17,9451 1,813 442 16,340 TOTAL 860 Total includes ventilation load for zonal systems. Ener ro7.2 h l=ner 5of1 User Number. 6712 ID: Page 35 of 51 ROOM HEATING PEAK LOADS Project Name Custom Residence ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-38 Roof Attic R19 High Performance R-21 Wall DOOR.39.27 Window .30.20 Window Slab -On -Grade *R-0 Interior Surface DESIGN CONDITIONS Master Time of Peak 1,772.00 ft2 Outdoor Dry Bulb Temperature 70 OF Area U-Value AT OF Date 612712018 Jan 1 AM 26 OF X 44 = 1,357 X 44 = 6,115 X 44 = 2,471 X 44 = 2,719 X 44 = 3,854 X 0 = 0 X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X Items shown with an asterisk (*) denote conduction through an interior surface to another room Page Total 16,516 Infiltration:[ 1.00 X 1.064 X 1, 772 X 11.80 X 0.323 / 60 X 44 = 5,271 Schedule Air Sensible Area Ceiling Height ACH i Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21.787 User Numbev 6712 ROOM HEATING PEAK LOADS Project Name Date Custom Residence 612712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great living Area Floor Area 2,064.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4T OF _ = = = = = = = = = = = = = = = = = = = = = = = = = = _ _ 44 Btu/hr R-36 Roof Atlrc R19 Nigh Performance 2,064.0 0.0174 44 1.580 R-21 Wall 1,880.1 0.0690 44 5,708 30.20 Window 227.9 0.3000 44 3.008 DOOR.39.27 Window 527.0 0.3900 44 9,043 Slab -On -Grade perim = 190.0 0.7300 44 6,103 'R-0 Interior Surface 500.0 0.3560 0 0 F Items shown with an asterisk (') denote conduction Infiltration:[ 1.00] X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,064 X Area another room 10.60 X 0.360 Height ACH Page Total / 60 X AT 25,443 _ 6,140 TOTAL HOURLY HEAT LOSS FOR ROOM 31,583 EnergyPro 7.2 by EnergySofd User Number: 6712 l0: Page 37 of 51 ROOM HEATING PEAK LOADS Project Name Custom Residence Date 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name dining Floor Area 480.00 ft2 Indoor Dry Bulb Tem erature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R30 480.0 0.0360 44 760 R-21 Wall 837.2 0.0690 44 2,542 .30.20 Window 82.3 0.3000 44 1.086 DOOR.39.27 Window 76.5 0.3900 44 1,313 Slab -On -Grade perim = 120.0 0.7300 44 3,854 "R-0 Interior Surface 480.0 0.3560 0 0 Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064i Schedule Air Sensible Fraction through an interior surface X 480 X Area another room 11.80 X 0.323 Height ACH Page Total / 60 J X AT 9,556 = 1,428 TOTAL HOURLY HEAT LOSS FOR ROOM 10,983 EnergyPro 7.2 by EnergySoit User Number: 6712 1D: Page 38 of 57 ROOM HEATING PEAK LOADS Project Name Custom Residence Date 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Second Floor Floor Area 1,187.00 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = c = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Attic R19 High Performance 1,187.0 0.0174 44 909 R-21 Watl 2,426.5 0.0690 44 7,367 .30.20 Window 125.5 0.3000 44 1,657 DCCR.39.27 Window 96.0 0.3900 44 1,647 R30 WIC CRAWLSPACE 822.0 0.0340 44 1,230 "R-0 Interior Surface 255.0 0.3560 0 0 through an interior surface X 1,187 X Area another room 9.00 X 0.424 Height ACH Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total / 60 ] X AT 12,809 3,531 TOTAL HOURLY HEAT LOSS FOR ROOM 16,340 EnergyPro 7.2 by EnergySofi User Number: 6712 ID: Page 39 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Ooaaue Surfaces R-38 Roof Attic R19 High Performa R-21 Wall R-21 Wall R-21 Wall R-21 Wall *R-0 Interior Surface Orientation (N) Master Outdoor Dry Bulb Temperature 1,772.00 ftZ Outdoor Wet Bulb Temperature 75 OF Outdoor Dailv Ranae: Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = 1,772.0 0.0174 56.0 536.0 0.0690 23.0 381.0 0.0690 33.0 713.0 0.0690 26.0 384.0 0.0690 33.0 500.0 0.3560 0.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestratinn 15 AM AL AK Al AN AH AG RR Orientation (N) (N) (N) (N) (N) (E) (E) (E) (E) Shaded Unshaded 112 OF 78 OF 34 OF Btu/hr 1.727 851 868 1,279 874 1 5,5991 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.8 40.0 17.8 0.0 13.4 3.0 13.4 0.0 13.4 3.0 13.4 0.0 13.4 3.0 13A 0.0 13.4 3.0 13.4 0.0 13.4 3.0 25.3 0.0 13.4 3.0 25.3 0.0 13.4 3.0 25.3 0.01 13.4 3.0 25.3 Page Total Btufhr 713 40 40 40 40 76 76 7s 1.1 Internal Gain Btufhr Occupants 5 3 Occupants X 245 Btuh/occ. = 1.304 Equipment 1,772 Floor Area X 0.50 w/sgft = 3,024 Infiltration: 1.064 X 1.20 X 87.27 X 37 T 4,131 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,432 Latent Gain Btu/hr Occupants 5•3 Occupants X 155 Btuh/occ. - 825 Infiltration: 4,771 X 1.20 X 87.27 X 0.00376 = 1,882 Air Sensible CFM ELA LAW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 8251 Ener Pro 7.2 by EnetvySoft User Number: 6712 ID: Pa e 40 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,772.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF e Surfaces Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD� = = = = = = = = = Btu/hr Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration QQ PP NN MM LL KK AF IAE IAD Orientation (E) (E) (E) (E) (E) (E) (E) (E) (E) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = Btu/hr 0.0 13.4 30 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 25.3 76 0.0 13.4 3.0 Page Total 683 Internal Gain Btu/hr Occupants 5 3 Occupants X 245 Btuh/occ. = 1,304 Equipment 1, 772 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.20I X 87.27 X 37 = 4,131 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,4 Latent Gain _ _ Btu/hr Occupants F 5 3 Occupants X _ _ 155 gtuh/occ. = Infiltration: 4,771 X 1.20 X F87.27, X 0.00376 = C Air Sensible CFM ELA. AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 825 Ener Pro 7.2 by Ener-qySoft User Number: 6712 ID: Paw 41 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Custom Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Surfaces Orientation Master Outdoor Dry Bulb Temperature 1,772.00 ft2 Outdoor Wet Bulb Temperature 75 °F Outdoor Dailv Range: Date 6/27/2018 Area U-Factor CLTD� _ X X = X X = X X = X X = X X 1 = X X� X X - X X - X X - Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF AC (E) 0.0 X 13.4 + 3.0 X 25.3 = AB (E) 0.0 X 13.4 + 3.0 X 25.3 = AU (S) 0.0 X 13.4 + 6.0 X 13.5 = ZZ (S) 0.0 X 13.4 + 42.0 X 13.5 = 14 (S) 0.0 X 17.8 + 104.0 X 17.9 = AA (S) 0.0 X 13.4 + 17.5 X 13.5 = Z (S) 0.0 X 13.4 + 17.5 X 13.5 = JJ (S) 0.0 X 13.4 + 3.0 X 13.5 = HH (S) 0.0 X 13.4 + 3.0 X 13.5 = Page Total Internal Gain Occupants 5•3 _ Occupants X 245 Btuh/occ. 1, 772 r Area X 0.501 w/sgft = Equipment Floor - Infiltration: 1.064 X 1.20 X 87 27 X 37 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 5 3 Occupants X 155] Btuh/occ. _ Infiltration: _ 4,771 X 0 X 87.27 X 0.00376 = Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7.2 bN Ener'gwSoft User Number: 6712 ID: 112 OF 78 OF 34 OF Btu/hr Btu/hr 76 76 81 566 1,8601 40 40 3,210 Btu/hr 1.304 3,024 4,131 20,432 Btu/hr 82! 1,882 82.9 7Q42of51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area ' 1,772.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor D Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X F X = X X = X X = X X = X X = X X = X X = X X = X X _ Page Total 0 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr GG (S) 0.0 X 13.4 + 3.0 X 13.5 = 40 FFF (S) 0.0 X 13.4 + 3.0 X 13.5 = 40 EE (S) 0.0 X 13.4 + 3.0 X 13.5 = 40 ❑D (S) 0.0 X 13.4 + 3.0 X 13.5 = 40 cc (S) 0.0 X 13.4 + 3.0 X 13.5 = 40 BB (S) 0.0 X 13.4 + 3.0 X 13.5 = 40 SS (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 TT (IM 0.0 X 13.4 + 3.0 X 25.3 = 76 UU (vo 0.0 X 13.4 + 3.0 X 25.3 = 76 Page Total 470 Internal Gain Btu/hr Occupants 5 3 Occupants X 245 Btuh/occ. = 1.304 Equipment 1,772 Floor Area X 0.50 w/sgft = 3,024 Infiltration: 1.064 X 1.20 X [ 87.27 X 37 = 4,131 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,432 Latent Gain Btu/hr Occupants 5.3 Occupants X 155 Btuh/occ. = 625 Infiltration: 4,771 X 7.20 X 87.27 X 0.00376 = 1.882 Air Sensible CFM ELA ❑VV TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 825 Ener.QyEro 7.2 by Enera Soft User Number: 6712 ID: Page 43 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,772.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr vv (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 A/W (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 xx (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 YY 0.0 X 13A + 3.0 X 25.3 = 76 S (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 T (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 U (IM 0.0 X 13.4 + 3.0 X 25.3 = 76 V (lM 0.0 X 13.4 + 3.0 X 25.3 = 76 W 0.0 X 13.4 + 3.0 X 25.3 = 76 Page Total 683 Internal Gain Btu/hr Occupants 5 3 Occupants X 245 Btuh/occ. = 1,304 Equipment 1.772 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.20 X 87.27 X 37 = 4.131 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,432 Latent Gain Btu/hr Occupants 53 Occupants X 155 Btuh/occ. = 825 Infiltration: 4,771 X 1.20 X 87.27 X 0.00376 = 1,882 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 825 EnerqyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 44 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,772.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation _ Area U-Factor CLTID Btu/hr X X - X X - X X - X X - X X = X X - X X - _ X X = X X - Page Total 0 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr X (� 0.0 X X. 13.4 + 3.0 X 25.3 = 76 y (►� 0.0 X , 13.4 + 3.0 X 25.3 = 76 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 152 Internal Gain Btu/hr Occupants 5.3 Occupants X 245 Btuh/occ. - 1,304 Equipment { 1,772 Floor Area X 0.50 w/ggft _ 3,024 Infiltration: 1.064 X 1.20 X �? X 37 = 4.131 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,432 Latent Gain Btu/hr Occupants 5 3 Occupants X j 155, Btuh/occ. 1.20 Infiltration: 4,771 X X 87.271 X 0.00376 = 1,882 Air Sensible CFM i [.A AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 825 EnenqyPro 7.2 by Ener Soft User Number: 6712 1D: Page 45 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Custom Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Great living Area Outdoor Dry Bulb Temperature Floor Area 2,064.00 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: opaque Surfaces R-38 Roof Attic R19 High Performa R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall 'R-0 Interior Surface Orientation (N) (N) (E) (SE) (S) (SI9 (VIO Date 6/27/2018 Area X X X X X X X X X U-Factor X X X X X X X X X CLTD1 = = = = = = = = = 2,064.0 0.0174 56.0 460.0 0.0690 23.0 306.5 0.0690 29.0 181.0 0.0690 33.0 360.6 0.0690 31.0 103.0 0.0690 26.0 96.0 0.0690 31.0 373.01 0.0690 33.0 500.0 0.3560 0.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1 Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF M (N) 0.0 X 13.4 + 6.0 X 13.4 = K (NE) 0.0 X 13A + 12.0 X 19.9 = 7 (NE) 0.0 X 17.8 + 20.0 X 26.5 = J (NE) 0.0 X 13.4 + 12.0 X 19.9 = H (NE) 0.0 X 13.4 + 37.5 X 19.9 = AT (E) 0.0 X 13A + 3.0 X 25.3 = AT (E) 0.0 X 13.4 + 3.0 X 25.3 = AT (E) 0.0 X 13.4 + 3.0 X 25.3 = AT (E) 0.0 X 13.4 + 3.0 X 25.3 = Page Total Internal Gain Occupants fi•2 Occupants X 245 Btuh/occ. _ Equipment 2,064 Floor Area X E-L0.50 w/sgft Infiltration: 1.064 X 120 X 101.65 X Air Sensible CFM EILA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 6.2 Occupants X F 155 Btuh/occ. Infiltration: 4,771 X 1.20 X 101.65 X 0.00376 W Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7.2 by EneravSoft User Number: 6712 ID 112 OF 78 OF 34 OF Btu/hr 2,0121 613 412 771 185 5, n238 76 76 76 2,135 Btu/hr 1,519 3.522 4,811 29,247 Btu/hr 961 2,192 961 7e 46 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Custom Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor ❑ry Bulb Lie Surfaces Great living Area Outdoor Dry Bulb Temperature 2,064.00 ft2 Outdoor Wet Bulb Temperature 75 OF Outdoor Daily Ranqe: Orientation Date 6/27/2018 Area X X X X X X X X X U-Factor X X X X X X X X X CLTD� = = = = = = = _ = Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1 Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration AT A 11 R Q P N Internal Gain Orientation (E) (SE) (SE) (SE) (VL9 W (�M Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 13.4 3.0 25.3 0.0 13.4 11.7 18.0 0.0 17.8 36.0 24.0 0.0 13.4 11.7 18.0 230.0 17.8 0.0 33.8 9.0 13.4 0.0 25.3 9.0 13.4 0.0 25.3 9.0 13.4 0.0 25.3 9.0 13.4 0.0I 25.3 Page Total Occupants 6.2 Occupants X 245 Btuh/occ. _ Equipment 2,064Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 1.20� X L 101.65 X 37 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 6 2 Occupants X 155] Btuh/occ. _ Infiltration: Fi�4,771 X 1.20 X 101.65 X 0.00376 = Air Sensible CFM ELA ❑W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 112 OF 78 OF 34 OF Btu/hr 0 Btu/hr 76 211 211 4,098 121 121 121 121 5, 944 Btu/hr 1.519 3,522 4, 811 29.247 Btu/hr 961 2,192 961 7.2 by EnemySoft User Number. 6712 ID. RESIDENTIAL ROOM COOLING LOAD SUMMARY Project name Custom Residence ROOM INFORMATION TDESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb T Surfaces Great living Area Outdoor Dry Bulb Temperature 2,064.00 ft2 Outdoor Wet Bulb Temperature 75 OF Outdoor Daily Range: Orientation Date 6/27/2018 Area X X X X X X X X U-Factor f CLTD' X _ X = X = X = X = X _ X = X = Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration 10 9 8 L 23 13 12 Internal Gain Orientation (IM (tM (KO (tM (IM (tM (IM Area X X X X X X X X X GLF + + + + + + + + + Area 0.5 X X X X X X X X X GLF = = = = = = = 35.5 17.8 33 8 60.0 13.4 0.0 25.3 20.0 13.4 0.0 25.3 6.0 13.4 0.0 25.3 15.7 17.8 4.3 33.8 117.0 17.8 0.0 33.8 67.1 17.8 0.9 33.8 Page Total Occupants 6.2 Occupants X �245 Btuh/occ.Epuipment 2,064 Floor Area X w/sgft = Infiltration: F 1.064 X 1.20 X L 101.E X 37 = Air Sensible CFtN E L A AT 112 OF 78 OF 34 OF Btu/hr Btu/hr 649 805 268 8111 H12, 085 ,225 5, Btu/hr 1,519 1 4,8111 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,247 Latent Gain Btu/hr Occupants 6.2 Occupants X F 1551 gtuh/occ. = 961 Infiltration: 4,771 X 1.20 X 101.65 X 0.00376 2,192 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 961 FA4 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name dining Outdoor Dry Bulb Temperature 112 OF Floor Area 480.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor D Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R30 (N) 480.0 X 0.0360 X 56.0 = 968 R-21 Wall (NE) 358.0 X 0.0690 X 29.0 = 716 R-21 Wall (SE) 183.5 X 0.0690 X 31.0 = 393 R-21 Wall (SVl7 199.7 X 0.0690 X 31.0 = 427 R-21 Wall (NVIO 96.0 X 0.0690 X 30.2 = 200 'R-0 Interior Surface 480.0 X 0.3560 X 0.0 = 0 X X = X X = X X = Page Total 2,704 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr G (NE) 0.0 X 13.4 + 6.0 X 19.9 = 119 F (NE) 0.0 X 13.4 + 16.0 X 19.9 = 318 2 (SE) 0.0 X 17.8 + 76.5 X 24.0 = 1,839 C (SW) 0.0 X 13.4 + 60.3 X 18.0 = 1,087 X + X = X + X = X + X = X + X = X + X = Page Total 3,36 Internal Gain Btu/hr Occupants 14 Occupants X 245 Btuh/occ. =L 353 Equipment 480 Floor Area X 0.50 w/sgft = 819 Infiltration: 1.064 X 1.20 X �23.64 X 37 = 1,119 Air Sensible CFM CLp. AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,357 Latent Gain Btu/hr Occupants 14 Occupants X 155 Btuh/occ. = 223 1.20 Infiltration: 4,771 X X 23.64 X 0.00376 = 510 AirSensibte CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 223 EnerqyPro 7.2 b Ene Soff User Number: 6712 JD_ Pa a 49 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 612712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Second Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,187.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 °F Outdoor Daily Range: 34 OF I Onaoue Surfaces R-38 Roof Aitic R19 High Performa R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R30 W/o CRAWLSPACE "R-0 hiterior Surface Orientation (N) (N) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = 1.187.0 0.0174 56.0 186.0 0.0690 23.0 890.5 0.0690 29.0 190.0 0.0690 31.0 780.0 0.0690 31.0 284.0 0.0690 33.0 96.0 0.0690 30.2 822.0 0.0340 19.0 255.0 0.3560 0.0! Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration BD BC BA AZ AY AX A AV BJ Internal Orientation (N) (NE) (NE) (NE) (NE) (NE) (NE) (SE) (SIM Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 13A 10.0 13.4 0.0 13.4 10.0 19.9 0.0 13.4 6.0 19.9 0.0 13.4 25.0 19.9 0.0 13.4 6.0 19.9 0.0 13.4 7.5 19.9 0.0 13.4 15.0 19.9 0.0 13.4 6.0 18.0 0.0 13.4 8.0 Page Total 3.6 Occupants X 2451 Btuh/occ. _ 1,187 Floor Area X 0.50i W/sgft Infiltration: 1.064 X 1.20 X 58.46 X 37 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 3 s ] Occupants X 1 155I Btuh/occ. W Infiltration: 4,771 X 1.20 X 58.46 X 0.00376 = Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7 User Number. 6712 Btu/hr 1,157 1 Btu/hr 134 199 119 496 119 149 29a 108 1,766 Btu/hr 873 2,026 2,767 17,945 Btu/hr 553 1,261 553 e 50 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 6/27/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Second Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,187.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X X X Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr SH (SIM 0.0 X 13.4 + 8.0 X 18.0 = 144 BG (SIM 0.0 X 13.4 + 8.0 X 18.0 = 144 BF (SIM 0.0 X 13.4 + 8.0 X 18.0 = 144 BE (SIM 0.0 X 13.4 + 8.0 X 18.0 = 144 30 (IM 0.0 X 17.8 + 96.0 X 33.8 = 3,250 X + X = X + X = X + X = X + X = Page Total 3,625 Internal Gain Btu/hr Occupants 3 6 Occupants X 245, Btuh/occ. = 873 Equipment 1,187 Floor Area X 0.50 w/sgft = 2,026 Infiltration: 1.064 X 1.20 X 58.45 X 3i = 2,767 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,945 Latent Gain Btu/hr Occupants 3 6 Occupants X 155 Btuh/occ. = 553 Infiltration: 4,771 X 1.20 X 58.46 X 0.00376 = 1,261 Air Sensible CFM ELA ❑w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 553 Enerq Pro 7.2 by Ener ySoft User Number: 6712 ID: Page 51 of 51