BRES2018-0165 Title 24I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Custom Residence
Lot 181 Hideaway
La Quinta, CA 92253
Project Designer:
Stracts, Inc
550 S. Oleander
Palm Springs„ CA 92264
(760) 636-8951
Report Prepared by:
Jon d. Scott
Scott Design and Title 24, Inc,
74818 Velie Way Suite 8
Palm Desert, CA 92260
(760) 200-4780
c5ptCC=
TY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
❑ATE 1kp\U% BYL
RECEIVE--%
Job Number:
JUL 19 2018
CITY OF LA QUINTA
Date: COMMUNITY DEVELOPMENT
6/27/2018
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standard
This program developed by EnergySoft Software —www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
1
Table of Contents
2
Form CF-1 R-PRF-01-E Certificate of Compliance
3
Form RMS-1 Residential Measures Summary
18
Form MF-1 R Mandatory Measures Summary
20
HVAC System Heating and Cooling Loads Summary
24
Zone Load Summary
28
Room Load Summary
32
Room Heating Peak Loads
36
Room Cooling Peak Loads
40
EnergyPro 7.2 by EnergySoft Job Number: ID: User Number: 6712 _ 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CFI R-PRF-01
Page I of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
GENERAL INFORMATION
01
Project Name
Lot 181 Hideaway
02
Calculation Description
Title 24 Analysis
03
Project Location
Lot 181 Hideaway
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.0 (1016 SP2)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
135
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
5503
15
Number of Zones
4
16
Slab Area (ft)
4316
17
Number of Stories
2
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
27.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.22
6.07
-1.85
-43.8%
Space Cooling
92.79
82.65
1014
10.9%
IAQ Ventilation
077
0.77
000
0.0%
Water Heating
259
696
-4.37
-168.7%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
100.37
96.45
3.92
3.9%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
CF1 R-PRF-01
Page 2 of 15
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
48.4 46.8
0.0
46.8
El
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Floor has high level of insulation
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• Pipe Insulation, All Lines
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 - Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 3 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Lot 181 Hideaway
5503
1
4
4
0
1
ZONE INFORMATION
01
02
03
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg, Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
HVAC-Master 4T1
1772
11.8
DHW Sys 1
n/a
great/kitchen
Conditioned
HVAC great 2-5 T2
2064
10.6
DHW Sys 1
n/a
service dining
Conditioned
HVAC-service 3T3
480
11 8
DHW Sys 1
n/a
Second Floor Zone
Conditioned
HVAC-2nd Fir 5T4
1187
9
DHW Sys 1
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CFI R-PRF-01
Page 4 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Master Suite
R-21 Wall
0
specify -
588
52
90
E Wall
Master Suite
R-21 Wall
90
- specify -
426
45
90
S Wall
Master Suite
R-21 Wall
180
specify -
924
211
90
W Wall
Master Suite
R-21 Wall
270
- specify -
426
42
90
Interior Surface
Master Suite»great/kitchen
R-0 Interior Surface
n/a
n/a
500
0
n/a
Roof 2
Master Suite
R-38 Roof Attic R19 High
n/a
n/a
1772
n/a
n/a
N Wall 2
great/kitchen
R-21 Wall
0
- specify -
466
6
90
NE Wall
great/kitchen
R-21 Wall
45
Right
388
81.5
90
E Wall 2
great/kitchen
R-21 Wall
90
- specify -
196
15
90
SE Wall
great/kitchen
R-21 Wall
135
Front
420
59.4
90
S Wall 2
great/kitchen
R-21 Wall
180
- specify -
103
0
90
SW Wall
great/kitchen
R-21 Wall
225
Left
96
0
90
W Wall 2
great/kitchen
R-21 Wall
270
specify -
966
593
90
Interior Surface 2
great/kitchen»service dining
R-0 Interior Surface
n/a
n/a
500
0
n/a
Roof 3
great/kitchen
R-38 Roof Attic R19 High
n/a
n/a
2064
n/a
n/a
NE Wall 2
service dining
R-21 Wall
45
Right
380
22
90
SE Wall 2
service dining
R-21 Wall
135
Front
260
76.5
90
SW Wall 2
service dining
R-21 Wall
225
Left
260
60.3
90
NW Wall
service dining
R-21 Wall
315
Back
96
0
90
Interior Surface 3
service dining»Second Floor Zone
R-0 Interior Surface
n/a
n/a
480
0
n/a
N Wall 3
Second Floor Zone
R-21 Wall
0
- specify -
196
10
90
NE Wall 3
Second Floor Zone
R-21 Wall
45
Right
960
69.5
90
SE Wall 3
Second Floor Zone
R-21 Wall
135
Front
196
6
90
SW Wall 3
Second Floor Zone
R-21 Wall
225
Left
820
40
90
W Wall 3
Second Floor Zone
R-21 Wall
270
- specify -
380
96
90
NW Wall 2
Second Floor Zone
R-21 Wall
315
Back
96
0
90
Interior Surface 4
Second Floor Zone»Master Suite
R-0 Interior Surface
n/a
n/a
255
0
n/a
Roof 4
Second Floor Zone
R-38 Roof Attic R19 High
n/a
n/a
1187
n/a
n/a
Raised Floor
Second Floor Zone
R30 W/O CRAWLSPACE
n/a
n/a
822
n/a
n/a
Registration Number: Registration DateMme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 5 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
Name
Zone
Type
Orientation
Area (ft2)
Skylight Area
(ft2)
Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Cool Roof
Roof
service dining
R30
- specify -
480
0
1
0.1
0.85
No
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Ventilated
3
0.61
0.86
Yes
Yes
Attic great/kitchen
Attic Roofgreat/kitchen
Ventilated
0.61
0.86
Yes
Yes
Attic Second Floor Zone
Attic RoofSecond Floor Zone
Ventilated
3
0.61
0.86
Yes
Yes
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 6 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
15
Window
N Wall (- specify --0)
1
40.0
0.39
0.27
Insect Screen (default)
AM
Window
N Wall (- specify --0)
-
-
1
3.0
0.30
0.20
Insect Screen (default)
AL
Window
N Wall (- specify --0)
--
---
1
3.0
0.30
0.20
Insect Screen (default)
AK
Window
N Wall (- specify --0)
1
3.0
0.30
0.20
Insect Screen (default)
AJ
Window
N Wall (- specify --0)
----
1
3.0
0.30
0.20
Insect Screen (default)
AN
Window
E Wall (- specify --90)
1
3-0
0.30
0.20
Insect Screen (default)
AH
Window
E Wall (- specify --90)
1
3.0
0.30
0.20
Insect Screen (default)
AG
Window
E Wall ( specify --90)
-
1
3.0
0.30
0.20
Insect Screen (default)
RR
Window
E Wall (- specify --90)
--
---
1
3.0
0.30
0.20
Insect Screen (default)
QQ
Window
E Wall (- specify --90)
--
1
3.0
0.30
0.20
Insect Screen (default)
PP
Window
E Wall (- specify --90)
-
---
1
3.0
0.30
0.20
Insect Screen (default)
NN
Window
E Wall ( specify --90)
-
1
3.0
0.30
0.20
Insect Screen (default)
MM
Window
E Wall (- specify -90)
-
1
3.0
0.30
0.20
Insect Screen (default)
LL
Window
E Wall (- specify -90)
-
-
1
3.0
0.30
0.20
Insect Screen (default)
KK
Window
E Wall (- specify --90)
- -
--
1
3.0
0.30
0.20
Insect Screen (default)
AF
Window
E Wall (- specify --90)
-
1
3.0
0.30
0.20
Insect Screen (default)
AE
Window
E Wall (- specify --90)
--
1
3.0
0.30
0.20
Insect Screen (default)
AD
Window
E Wall (- specify --90)
----
1
3.0
0.30
0.20
Insect Screen (default)
AC
Window
E Wall (- specify --90)
1
3.0
0.30
0.20
Insect Screen (default)
AB
Window
E Wall (- specify --90)
----
- -
1
3.0
0.30
0.20
Insect Screen (default)
AU
Window
S Wall (- specify --180)
----
1
6.0
0.30
0.20
Insect Screen (default)
ZZ
Window
S Wall (- specify --180)
--
-
1
42.0
0.30
0.20
Insect Screen (default)
14
Window
S Wall (- specify --180)
----
--
1
104.0
0.39
0.27
Insect Screen (default)
AA
Window
S Wall (- specify --180)
-
1
17.5
0.30
0.20
Insect Screen (default)
Z
Window'
S Wall (- specify --180)
----
1
17.5
0.30
0.20
Insect Screen (default)
JJ
Window
S Wall (- specify --180)
----
---
1
3.0
0.30
0.20
Insect Screen (default)
HH
Window
S Wall (- specify --180)
- -
-
1
30
0.30
0.20
Insect Screen (default)
GG
Window
S Wall (- specify --180)
---
---
1
3.0
0.30
0.20
Insect Screen (default)
FFF
Window
S Wall (- specify --180)
---
1
3.0
0.30
0.20
Insect Screen (default)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
CF1 R-PRF-01
Page 7 of 15
EE
Window
S Wall (- specify --180)
----
1
3.0
0.30
1 0.20
Insect Screen (default)
DD
Window
S Wall (- specify --180)
---
1
3.0
0.30
0.20
Insect Screen (default)
CC
Window
S Wall (- specify --180)
-
1
3.0
0.30
020
Insect Screen (default)
BB
Window
S Wall (- specify --180)
----
----
1
3.0
0.30
0.20
Insect Screen (default)
SS
Window
W Wall (- specify --270)
1
3.0
0.30
0.20
Insect Screen (default)
TT
Window
W Wall (- specify --270)
1
3.0
0.30
0.20
Insect Screen (default)
UU
Window
W Wall (- specify --270)
-
---
1
3.0
0.30
0.20
Insect Screen (default)
VV
Window
W Wall (- specify --270)
-
1
3.0
0.30
0.20
Insect Screen (default)
WW
Window
W Wall (- specify --270)
----
.---
1
3.0
0.30
0.20
Insect Screen (default)
XX
Window
W Wall (- specify --270)
-
1
3.0
0.30
0.20
Insect Screen (default)
YY
Window
W Wall (- specify --270)
----
1
3.0
0.30
0.20
Insect Screen (default)
S
Window
W Wall (- specify --270)
----
1
3.0
0.30
0.20
Insect Screen (default)
T
Window
W Wall (- specify --270)
-
1
3.0
0.30
0.20
Insect Screen (default)
U
Window
W Wall (- specify --270)
--
1
3.0
0.30
0.20
Insect Screen (default)
V
Window
W Wall (- specify --270)
----
----
1
3.0
0.30
0.20
Insect Screen (default)
W
Window
W Wall (- specify --270)
-
1
3.0
0.30
0.20
Insect Screen (default)
X
Window
W Wall (- specify --270)
---
-
1
30
0.30
0.20
Insect Screen (default)
Y
Window
W Wall (- specify --270)
-
---
1
3.0
0.30
0.20
Insect Screen (default)
M
Window
N Wall 2 (- specify --0)
---
--
1
6.0
0.30
0.20
Insect Screen (default)
K
Window
NE Wall (Right-45)
-
--
1
12.0
0.30
0.20
Insect Screen (default)
7
Window
NE Wall (Right-45)
-
1
20.0
0.39
0.27
Insect Screen (default)
J
Window
NE Wall (Right-45)
-
---
1
12.0
0.30
0.20
Insect Screen (default)
H
Window
NE Wall (Right-45)
----
-
1
37.5
0.30
0.20
Insect Screen (default)
AT
Window
E Wall 2 (- specify --90)
--
1
3.0
0.30
0.20
Insect Screen (default)
AT 2
Window
E Wall 2 (- specify --90)
-
-
1
3.0
0.30
0.20
Insect Screen (default)
AT 3
Window
E Wall 2 (- specify --90)
-
1
3.0
0.30
020
Insect Screen (default)
AT 4
Window
E Wall 2 (- specify --90)
-
--
1
3.0
0.30
0.20
Insect Screen (default)
AT 5
Window
E Wall 2 (- specify --90)
1
3.0
0.30
0.20
Insect Screen (default)
B
Window'
SE Wall (Front-135)
-
1
11.7
0.30
0.20
Insect Screen (default)
1
Window
SE Wall (Front-135)
-
--
1
36.0
0.39
0.27
Insect Screen (default)
A
Window
SE Wall (Front-135)
----
----
1
11.7
0.30
0.20
Insect Screen (default)
11
Window
W Wall 2 (- specify --270)
23.0
10.0
1
230.0
0.39
0.27
Insect Screen (default)
R
Window
W Wall 2 (- specify --270)
30
3.0
1
9 0
0.30
0.20 1
Insect Screen (default)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 8 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
Q
Window
W Wall 2 (- specify --270)
3.0
3.0
1
9.0
0.30
0.20
Insect Screen (default)
P
Window
W Wall 2 (- specify --270)
3.0
3.0
1
9.0
0.30
0.20
Insect Screen (default)
N
Window
W Wall 2 (- specify --270)
3.0
3.0
1
9.0
0.30
0.20
Insect Screen (default)
10
Window
W Wall 2 (- specify --270)
4.5
8.0
1
36.0
0.39
0.27
Insect Screen (default)
9
Window
W Wall 2 (- specify --270)
7.5
8.0
1
60.0
0.30
0.20
Insect Screen (default)
8
Window
W Wall 2 (- specify --270)
2.5
8.0
1
20.0
0.30
0.20
Insect Screen (default)
L
Window
W Wall 2 (- specify --270)
2.0
3.0
1
6.0
0.30
0.20
Insect Screen (default)
23
Window
W Wall 2 (- specify --270)
2.5
8.0
1
20.0
0.39
0.27
Insect Screen (default)
13
Window
W Wall 2 (- specify --270)
11.7
10.0
1
117.0
0.39
0.27
Insect Screen (default)
12
Window
W Wall 2 (- specify --270)
8.5
8.0
1
68.0
0.39
0.27
Insect Screen (default)
G
Window
NE Wall 2 (Right-45)
----
---
1
6.0
0.30
0.20
Insect Screen (default)
F
Window
NE Wall 2 (Right-45)
1
16.0
0.30
0.20
Insect Screen (default)
2
Window
SE Wall 2 (Front-135)
1
76.5
0.39
0.27
Insect Screen (default)
C
Window
SW Wall 2 (Left-225)
1
60.3
0.30
0.20
Insect Screen (default)
BD
Window
N Wall 3 (- specify --0)
----
----
1
10.0
0.30
0.20
Insect Screen (default)
BC
Window
NE Wall 3 (Right-45)
----
--
1
10.0
0.30
0.20
Insect Screen (default)
BA
Window
NE Wall 3 (Right-45)
----
1
6.0
0.30
0.20
Insect Screen (default)
AZ
Window
NE Wall 3 (Right-45)
-
1
25.0
0.30
0.20
Insect Screen (default)
AY
Window
NE Wall 3.(Right-45)
1
6.0
0.30
0.20
Insect Screen (default)
AX
Window
NE Wall 3 (Right-45)
-
-
1
7.5
0.30
0.20
Insect Screen (default)
AW
Window
NE Wall 3 (Right-45)
--
--
1
15.0
0.30
0.20
Insect Screen (default)
AV
Window
SE Wall 3 (Front-135)
-
--
1
6.0
0.30
0.20
Insect Screen (default)
BJ
Window
SW Wall 3 (Left-225)
-
1
8.0
0.30
0.20
Insect Screen (default)
BH
Window
SW Wall 3 (Left-225)
--•-
- -
1
8.0
0.30
0.20
Insect Screen (default)
BG
Window
SW Wall 3 (Left-225)
----
-
1
8.0
0.30
0.20
Insect Screen (default)
BF
Window
SW Wall 3 (Left-225)
----
----
1
8.0
0.30
0.20
Insect Screen (default)
BE
Window
SW Wall 3 (Left-225)
1
8.0
0.30
0.20
Insect Screen (default)
30
Window
W Wall 3 (- specify --270)
1
96.0
0.39
0.27
Insect Screen (default)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Lot 181 Hideaway
Calculation Description: Title 24 Analysis
Calculation Date/Time: 08:50, Wed, Jun 27, 2018
Input File Name: tmpDF69.tmp.xml
Page 9 of 15
OVERHANGS AND FINS
01
02
03
04
05
06
07
08 09
10
11
12
13
1 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
11
18
0.1
18
18
0
0
0
0
0
0
0
0
0
R
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Q
8
0.1
8
8
0
0
0
0
0
0
0
0
0
P
8
01
8
8
0
0
0
0
0
0
0
0
0
N
8
0.1
8
8
0
0
0
0
0
0
0
0
0
10
10
01
10
10
0
0
0
0
0
0
0
0
0
9
16
0.1
16
16
0
0
0
0
0
0
0
0
0
8
16
0.1
16
16
0
0
0
0
0
0
0
0
0
L
8
0.1
8
8
0
0
0
0
0
0
0
0
0
23
8
0.1
8
8
0
0
0
0
0
0
0
0
0
13
16
0.1
16
16
0
0
0
0
0
0
0
0
0
12
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation DatefTime: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 10 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Suite
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic R19 High
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C:
R 38
0.025
Over Ceiling Joists: R-28 9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Interior Surface
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
• Around Roof Joists: R-6.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofgreat/kitchen
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-30/2x10
• Roof Deck: Wood Siding/sheathing/decking
R30
Cathedral Ceilings
Wood Framed Ceiling
2xl0 @ 16 in O.C.
R 30
0 037
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofSecond Floor Zone
Attic Roofs
Wood Framed Ceiling
in O.C.
R 19
0.059
Roofing: Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
R30 W/O CRAWLSPACE
Exterior Floors
Wood Framed Floor
2x6 @ 16 in. 0 C.
R 30
0.037
Cavity/Frame: R-30/2x6
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value 8• Depth
Carpeted Fraction
Heated
Slab -on -Grade
Master Suite
1772
120
None
0.8
No
Slab -on -Grade 2
great/kitchen
2064
190
None
0.8
No
Slab -on -Grade 3
service dining
480
120
None
0.8
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 11 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
(HERS req'd) Pipe Insulation, All
Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Large Storage
1
100
0.8 frac
85,000 Btu/hr
R-0/R-0
0.03
n/a
n/a
n/a
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
Pipe Insulation, All Lines
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
62
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC-Master 4T1
Other Heating and Cooling System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC great 2-5 T2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC-service 3T3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC-2nd Flr 5T4
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 12 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Heating Component 2
CntrlFurnace
2
80 AFUE
Heating Component 3
CntrlFurnace
1
80 AFUE
Heating Component 4
CntrlFurnace
1
80 AFUE
HVAC -COOLING UNIT TYPES
01
02
03
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
2
12.7
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
12.7
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
1
12.7
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Registration Number: Registration DatefTlime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 13 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
2-hers-dist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
3-hers-dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
4-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.56
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.56
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.56
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.56
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.56
HVAC Fan 2-hers-fan
Required
0.56
HVAC Fan 3-hers4an
Required
0.56
HVAC Fan 4-hers-fan
Required
0.56
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Page 14 of 15
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
93
0.25
Default
0
Required
Registration Number: Registration DatefTime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Lot 181 Hideaway Calculation Date/Time: 08:50, Wed, Jun 27, 2018
CF1 R-PRF-01
Calculation Description: Title 24 Analysis
Input File Name: tmpDF69.tmp.xml
Page 15 of 15
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jon d. Scott
Company:
Signature Date:
Scott Deign and Title 24, Inc,
6/27/2018
Address:
74818 VeIie Way Suite 8
CEA/HERS Certification Identification (If applicable):
City/Statei[Zip:r Desert, CA 92260
Phone: (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application
Responsible Desier Name:
Anton 1Parinkavich
Responsible Designer Signature:
Company:
StraciS, Inc
Date Signed:
Address:
550 S. Oleander
License:
City/StateMp:
Palm Springs„ CA 92264
Phone:
(760) 636-8951
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06212018-1016 SP2 Report Generated at: 2018-06-27 08:51:48
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Custom Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
612712018
Project Address
Lot 181 Hideaway La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,503
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft)
Special Features
Status
Roof Wood Framed Attic
R 38 5,023
Add=R-19.0 Cool Roof
New
Wall Wood Framed
Slab Unheated Slab -on -Grade
R 21 7,158
- no insulation 4,316
Perim = 430'
New
New
Demising Wood Framed
- no insulation 1,735
New
Roof Wood Framed Rafter
R 30 480
New
Floor Wood Framed w/o Crawl Space R 30 822
New
FENESTRATION
Orientation Area fe
Total Area: 1,485 Glazing Percentage: 27.0% New/Altered Average U-Factor:
U-Fac SHGC Overhang Sidefins Exterior Shades
0.35
Status
Rear (N) 40.0
0.390
0.27 none
none Bug Screen
New
Rear (N) 28.0
0.300
0.20 none
none Bug Screen
New
Right (E) 60.0
0.300
0.20 none
none Bug Screen
New
Front (S) 107.0
0.300
0.20 none
none Bug Screen
New
Front (S) 104.0
0.390
0.27 none
none Bug Screen
New
Left (W) 42.0
0.300
0.20 none
none Bug Screen
New
Right (NE) 153.0
0.300
0.20 none
none Bug Screen
New
Right (NE) 20.0
0.390
0.27 none
none Bug Screen
New
Front (SE) 2R4
0.300
0.20 none
none Bug Screen
New
Front (SE) 112.5
0.390
a27 none
none Bug Screen
New
Left (W) 230.0
0.390
0.27 18.0
none Bug Screen
New
Left (Kq 42.0
0.300
0.20 8.0
none Bug Screen
New
Left (lM 104.0
0.390
0.27 10.0
none Bug Screen
New
Left (lM 80.0
0.300
0.20 16.0
none Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff Thermostat
Status
1 Central Furnace
80% AFUE
Split Air Conditioner
16.0 SEER Setback
New
2 Central Furnace
80% AFUE
Split Air Conditioner
16, 0 SEER Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner
16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value
Status
HVAC-Master 4T Ducted
Ducted Attic
8.0
New
HVAC great 2-5 T Ducted
Ducted Attic
8.0
New
HVAC-service 3T Ducted
Ducted Attic
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff
Distribution
Status
1 Large Storage Gas
100
0.80
All Pipes Ins (HERS)
New
EnergyPro 7.2 by EnerovSoft User Number: 6712
ID:
Page 18 of 51
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Custom Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/27/2018
Project Address
Lot 181 Hideaway La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,503
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
FENESTRATION I Total Area: 1,485 Glazing Percentage- 27.0% New/Altered Average U-Factor:
Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades
0.35
Status
Left (140 20.0 0.390
0.27 8.0 none Bug Screen
New
Left (W 117.0 0.390
0.27 16.0 none Bug Screen
New
Left (SWJ 100.3 0.300
0.20 none none Bug Screen
New
Left (lM 96.0 0.390
0.27 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC-2nd Flr 5T Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener vPro 7.2 by Enera Soft User Number: 6712
ID-
Pa e 19 of 51
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(0rininA W On16)
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/l.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.E-A and 110,6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R.
§ 110.8(j):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average 1-1-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceilin .'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(0:
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 permlinch; be protected from physical damage and UV light
deterioration; and, when installed as art of a heated slab floor, meet the requirements of § 110.8 .
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation,
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is hi her than the cut-off temperature for supplementary heatin .'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
L150. (h)I
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using desi ri conditions specified in 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
d er vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve."
§ 150.0(j)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A• Distribution
piping for steam and hydronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)l:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5•
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corooration (SRCC) or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)l:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11;
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)l 1 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)l 2.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
§ 150.0(m)13:
grilles, and an air -handling unit fan efficacy 5 0,58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
§ 150.0(o)1A:
testin , in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
§ 110.4(a):
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
§ 110.4(b)1:
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2;
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
§ 110.4(b)3:
will allow all pum2s to be set or programmed to run only during off- eak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
150.0
§ (p)'
rate. piping, fillers, and valves.'
Lighting Measures:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
§ 110.9:
of & 110.9.'
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
§ 110.9(e):
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan sp2ed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 Ct
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
§ 150.0(k)1 D:
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
b vacancy sensors.
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
§ 150.0(k)1 F:
must meet the applicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G:
with Reference Joint Appendix JA8. Installed lamps must be marked with'JA8-2016' or "JA8-2016-E' as specified in Reference Joint Appendix
JA8'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with'JA8-2016-E.'
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
§ 150.0(k)2C:
switched ON and OFF,
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions,
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
§ 150.0(k)2E:
§ 150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other re uirements in § 150.0k Z
Interior Switches and Controls, An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0k 2.
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
§ 150.0(k)21:
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
A nft, JL 2016 Low -Rise Residential Mandato Measures Summary
§ 150.0(1k)2S Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallwa '
§ 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3AN (photo control and automatic time switch control, astronomical time clock, or
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0 k 3A or with the applicable requirements in 110.9.130.0,130.2,130.4 1401 and 141.0.
§ 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or§ 150.0(k)30 mustcomply with the applicable r uirements in 110.9, 130.0,130.2. 130,4,140,7 and 141.0.
§ 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must com I with the a licable requirements in 110.9, 130.0.130.2,13044 140.7, and 141.0.
§ 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garNes in iq 110.9, 130A 130.1, 130.4, 140.6. and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be hl h efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0, 130.1, 140.E and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percenil. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
r29 uirements of § 110.10 b throu h' 110.10 e
§ 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110,10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1: greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area:
§ 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zm measured in the vertical lane.'
§ 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly Indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel): and a Whway for roufin2 of plumbing from the solar zone to the water -heating s stem.
§ 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
1 10.10c must be provided to the occupant.
§ 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit locabon; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence
System Name
HVAC-Master 4T
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1 COIL COOLING PEAK
Heating System CFM Sensible Latent
Output per System 61,000 Total Room Loads
Total Output Btuh) 61,000 Return Vented Lighting
Output (Btuh/sgft) 34.4 Return Air Ducts
Cooling System Return Fan
Output perSystem 49,000 Ventilation
9881 20,4321 2,707
0
Total Output (Btuh)
49,000
Supply Fan
4
Total Output (Tons)
4•1
Supply Air Ducts
C
Total Output (Btuh/sqft)
27.7
Total Output (sgft/Ton)
434.0
TOTAL SYSTEM LOAD
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow(cfm)
1,600
Carrier 24ANB748-58CVX080
Airflow (cfmis ft)
0.90
Airflow (cfm/Ton)
391.8
Outside Air (%)
0.0%
Total Adjusted System Output
0.00
(Adjusted for Peak Design conditions)
Outside Air (cfm/s ft)
Note: values above given at ARI
conditions
TIME OF SYSTEM PEAK
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Pea
70 OF
105 °[
105 OF
M
•
Outside Air
llllll
-4
0 cfm
V-
Heating Coil Supply Fan
1,600 cfm
0 0
0
963
22,358 2,707
36,5601 5,056
36.5601 5,
Aug 3
Date
6/27/2018
Floor Area
1,772
COIL HTG. PEAK
CFM Sensible
5931 21,787
23,451
61,000
1 61,0001
Jan 1
105 OF
ROOD
70 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 l 78 OF 76 l 62 OF 55 / 54 OF 55 l 54 °F
Outside Air _
0
Supply Fan 56154 °F
cfm Cooling Coil
1,600 cfm
48.1% ROOM
76,162 °F 751 62 °F
7.2 by EnergySoft User Number 6712 ID: Page 24 of 51
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence
System Name
HVAC great 2-5 T
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1 1.1
Output per System
89,000
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
Total Output Btuh)
178,000
Out ut Bft tuh1s
86.2
CoolingSystem
Output per System
57,500
Total Output Btuh
115,000
Total Output (Tons)
9.6
Total Output Stuh/s ft
55.7
at
Total Outn,ISrifflronl
215.4
Air Svstem
Date
6/27/2018
Floor Area
2,064
COIL COOLING PEAK
COIL HTG.
PEAK
CFM
Sensible
Latent
CFM
Sensible
1,397
29,247
3,153
855
31,583
0
1,378
1.206
0
0
0
0 0
0
179
1,378
32,182 3,153
-179
1,206
33,815
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm
4,000
Carrier 24ANB760/58PH"'110
85,508
11,576
178,000
Airflow (cfmis ft)
1.94
Airflow (cfm/Ton
41T4
Outside Air
p•0%
Total Adjusted System Output 85,5081 11,576 178,000
(Adjusted for Peak Design conditions)
0.00
Outside Air (cfmisgft)
Note: values above given at ARI conditions TIME OF SYSTEM PEAK 1 Aug 3 PM Jan 1
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 OF 70 OF 105 IF 105 OF
I- I.
Outside Air t
0 cfm Heating Coil Supply Fan
105 °F
4,000 cfm
ROOM
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak)
112 / 78 OF 75 162 OF 55 / 54 OF 55154 °F
Outside Air
Supply Fan
0 cfm Cooling Coil
4,000 cfm
47.0%
70 OF
55 / 54 OF
ROOM
5/6l
7.2 by EnergySoR User Number 6712 ID: Page 25 of 51
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Custom Residence
6/27/2018
Floor Area
System Name
HVAC-service 3T
480
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
COOLING PEAK COIL HTG.
PEAK
Heating System
CFM
Total Room Loads 399
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation i 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
Sensible Latent CFM
8,357 733 298
0
394
0
0 0 0
0
394
F 9,145 733
Sensible
Output per System
51,000
10,983
Total Output Btuh
51,000
Output (Btuh/sgft)
106.3
419
Cooling System
0
Output per System
36,000
0
Total Output (Btuh)
36,000
0
Total Output Tons
3.0
419
Total Output (Btuh/s ft)
75.0
Total Output (s ft/Ton
160.0
11,822
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,200
Carrier 24ANB736/58PH**070
26,373
3,980
51,000
Airflow (cfm/sqft)
2.50
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
26,373 3,980 51,000
0.00
Outside Air (cfm/sgft)
TIME OF SYSTEM PEAK
Aug 3 PUIJan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating
Peak
26 OF
70 OF 105 OF 105 IF
Outside Air
0 cfm
Heating Coil Supply Fan
°
105 F
1,200 cfm
ROOM
70 °F
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak)
1112/78OF
75 162 OF 55 / 54 OF 55154 OF
10
Outside Air
0 cfm
Supply Fan
Cooling Coil
55 / 54 OF
AL
1,200 cfm
46.8% ROOM
75 162 OF
75 ! 62 OF
n I
tl f
EnergyPro 7.2 by EnergySoft
User Number: 6712
ID: Page 26 of 51
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence
Date
6/27/2018
System Name
HVAC-2nd Fir 5T
Floor Area
1,187
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 860
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
17,945
1,813
442
16,340
Total Output (Btuh)
89,000
0
Output Btuh/s ft
75.0
846
624
Cooling System
0
0
Output per System
57,500
0
0
0
0
Total Output (Btuh)
57,500
89
1,813
-89
Total Output Tons
4•8
846
624
Total Output (Btuh/sgft)
48.4
Total Output (s ft[Ton
247-7
19,726
17,499
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
2,000
Carrier 24ANB760/58PH""110
42,769
5,822
89,000
Airflow (cfm/s ft)
1.68
Airflow (cfm/Ton)
417.4
Outside Air (%)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
42,769 5,822 89,000
Aug 3 PM Jan 1 AM
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating
Peak)
—0-0- 1p
Outside Air
0 cfm
70 IF 105 OF 105 OF
S
Heating Coil Supply Fan
2,000 cfm
ROOM �^
70 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 /78OF
Outside Air
0 cfm
AL
14
Cooling Coil Supply Fan;
2,000 cfm
54
47.2% ROOM
EnergyPro 7.2 by EnergySoff User Number: 6712
/D: Page 27 of 5l
ZONE LOAD SUMMARY
Project Name
Custom Residence
Date
6/27/2018
System Name
HVAC-Master 4T
Floor Area
1,772
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING
PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Master Suite
1.0
0
Aug 3 PM
988
20,432
2,707
593
21,787
TOTALS
0
0
0
0
Aug 3 PM
20,432
2,707
21,787
(BLOCK LOAD)
EnergyPro 7.2 by EnergySvR User Number: 6712 10. Page 28 of 51
ZONE LOAD SUMMARY
Project Name
Custom Residence
Date
6/27/2018
System Name
HVAC great 2-5 T
Floor Area
2,064
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING
PEAK
HEATING
PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
I Latent
CFM
Sensible
great/kitchen
1.0
0
Aug 3 PM
1,397
29,2471
3,153
855
31,583
TOTALS
0
0
0
0
Aug 3 PM
29,247
3,153
31,583
BLOCK LOAD)
EnergyPro 7.2 by EnergySa t User Number 6712 ID: Page 29 of 51
ZONE LOAD SUMMARY
Project Name
Custom Residence
System Name
HVAC-service 3T
Date
6/27/2018
Floor Area
480
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING
PEAK
HEATING
PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
service dining
1.0
0
Aug 3 PM
399
8,357
733
298
10,983
TOTALS
0
0
0
0
Aug 3 PM
8,357
733
10,983
BLOCK LOAD)
EnergyPro 7.2 by FnergySoR User Number.' 6712 ID: Page 30 of 51
ZONE LOAD SUMMARY
Project Name
Custom Residence
Date
6/27/2018
System Name
HVAC-2nd Fir 5T
Floor Area
1,187
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Second Floor Zone
1.0
0
Aug 3 PM
660
17,945
1,813
442
16,340
TOTALS
0
0
01
01
Aug 3 PM
1 17,945
1,813
16,340
(BLOCK LOAD
Er�ergyPro 7.2 by EnergyScR User Number: 6712 la: Page 37 of 51
ROOM LOAD SUMMARY
Project Name Date
Custom Residence 6/27/2018
System Name Floor Area
HVAC-Master 4T 1,772
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFM Sensible
Master Suite I Master 1 1 9881 20, 432 2,7079 9881 20,4321 2, 707 593 21, 787
PAGE TOTAL
TOTAL*
988
20,4321
2,7071 593
21,787
988
20,432
2,707 593
21,787
Total includes ventilation load for zonal systems.
EnergyPro 7.2 by EneravSoft User Number., 6712 ID: Page 32 of 51
ROOM LOAD SUMMARY
Project Name
Custom Residence
System Name
HVAC great 2-5 T
ROOM LOAD SUMMARY
ROOM COOLING PEAK
Zone Name Room Name Mult. CFM I Sensible I Latent
great/kitchen Great living Area 1 1.397 29,247 3,153
PAGE TOTAL
TOTAL "
Date
612712018
Floor Area
2,064
COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible Latent CFM Sensible
1,3971 29,2471 3,153 855 31, 583
1,3971
29,247
3,153
855 31,583
1.397
29,247
3,153
855 31,583
Total includes ventilation load for zonal s ster
EneravPro 7.2 kv Energv5oft User Number.
33 of 51
ROOM LOAD SUMMARY
Project Name Date
Custom Residence 6/27/2018
System Name Floor Area
HVAC-service 3T 480
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name I Room Name Mult. I CFM Sensible I Latent CFM Sensible Latent CFM Sensible
service dining dining 1 399 8,3571 733 399 8,3571 733 298 10, 983
PAGE TOTAL
TOTAL'`
399
8.357
7331
2981
10,983
3991
8,357
7331
2981
10,983
" Total includes ventilation load for zonal systems.
EneryvPro 7.2 by EneravSoft User Number: 6712 ID: Page 34 of 51
ROOM LOAD SUMMARY
Project Name
Date
Custom Residence
6/27/2018
System Name
Floor Area
HVAC-2nd Flr 5T
1.187
ROOM LOAD SUMMARY
ROOM
COOLING
PEAK COIL
COOLING
PEAK COIL HTG.
PEAK
Zone Name
Room Name
Mult. CFM
Sensible
Latent CFM I
Sensible
Latent CFM
Sensible
Second Floor Zone
Second Floor
1 860
17,945
1,813 860
17,945
1,813 442
16,340
PAGE TOTAL
860
17,945
1,1113
4421
16,340
17,9451
1,813
442
16,340
TOTAL
860
Total includes ventilation
load for zonal systems.
Ener ro7.2 h l=ner 5of1
User Number. 6712
ID:
Page
35 of 51
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temperature
Conduction
R-38 Roof Attic R19 High Performance
R-21 Wall
DOOR.39.27 Window
.30.20 Window
Slab -On -Grade
*R-0 Interior Surface
DESIGN CONDITIONS
Master Time of Peak
1,772.00 ft2 Outdoor Dry Bulb Temperature
70 OF
Area
U-Value
AT OF
Date
612712018
Jan 1 AM
26 OF
X 44 = 1,357
X 44 = 6,115
X 44 = 2,471
X 44 = 2,719
X 44 = 3,854
X 0 = 0
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X =
X
Items shown with an asterisk (*) denote conduction through an interior surface to another room Page Total 16,516
Infiltration:[ 1.00 X 1.064 X 1, 772 X 11.80 X 0.323 / 60 X 44 = 5,271
Schedule Air Sensible Area Ceiling Height ACH i
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
21.787
User Numbev 6712
ROOM HEATING PEAK LOADS
Project Name Date
Custom Residence 612712018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Great living Area
Floor Area 2,064.00 ft2
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4T OF
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_
_
44
Btu/hr
R-36 Roof Atlrc R19 Nigh Performance
2,064.0
0.0174
44
1.580
R-21 Wall
1,880.1
0.0690
44
5,708
30.20 Window
227.9
0.3000
44
3.008
DOOR.39.27 Window
527.0
0.3900
44
9,043
Slab -On -Grade
perim = 190.0
0.7300
44
6,103
'R-0 Interior Surface
500.0
0.3560
0
0
F
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00] X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 2,064 X
Area
another room
10.60 X 0.360
Height ACH
Page Total
/ 60 X
AT
25,443
_ 6,140
TOTAL HOURLY HEAT LOSS FOR ROOM 31,583
EnergyPro 7.2 by EnergySofd User Number: 6712 l0: Page 37 of 51
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
Date
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name dining
Floor Area 480.00 ft2
Indoor Dry Bulb Tem erature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
R30
480.0
0.0360
44
760
R-21 Wall
837.2
0.0690
44
2,542
.30.20 Window
82.3
0.3000
44
1.086
DOOR.39.27 Window
76.5
0.3900
44
1,313
Slab -On -Grade
perim = 120.0
0.7300
44
3,854
"R-0 Interior Surface
480.0
0.3560
0
0
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064i
Schedule Air Sensible
Fraction
through an interior surface
X 480 X
Area
another room
11.80 X 0.323
Height ACH
Page Total
/ 60 J X
AT
9,556
= 1,428
TOTAL HOURLY HEAT LOSS FOR ROOM 10,983
EnergyPro 7.2 by EnergySoit User Number: 6712 1D: Page 38 of 57
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
Date
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Second Floor
Floor Area 1,187.00 ftz
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
R-38 Roof Attic R19 High Performance
1,187.0
0.0174
44
909
R-21 Watl
2,426.5
0.0690
44
7,367
.30.20 Window
125.5
0.3000
44
1,657
DCCR.39.27 Window
96.0
0.3900
44
1,647
R30 WIC CRAWLSPACE
822.0
0.0340
44
1,230
"R-0 Interior Surface
255.0
0.3560
0
0
through an interior surface
X 1,187 X
Area
another room
9.00 X 0.424
Height ACH
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
Page Total
/ 60 ] X
AT
12,809
3,531
TOTAL HOURLY HEAT LOSS FOR ROOM 16,340
EnergyPro 7.2 by EnergySofi User Number: 6712 ID: Page 39 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Custom Residence 6/27/2018
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
Indoor Dry Bulb
Ooaaue Surfaces
R-38 Roof Attic R19 High Performa
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
*R-0 Interior Surface
Orientation
(N)
Master Outdoor Dry Bulb Temperature
1,772.00 ftZ Outdoor Wet Bulb Temperature
75 OF Outdoor Dailv Ranae:
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
1,772.0
0.0174
56.0
536.0
0.0690
23.0
381.0
0.0690
33.0
713.0
0.0690
26.0
384.0
0.0690
33.0
500.0
0.3560
0.0
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestratinn
15
AM
AL
AK
Al
AN
AH
AG
RR
Orientation
(N)
(N)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
Shaded Unshaded
112 OF
78 OF
34 OF
Btu/hr
1.727
851
868
1,279
874
1 5,5991
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
17.8
40.0
17.8
0.0
13.4
3.0
13.4
0.0
13.4
3.0
13.4
0.0
13.4
3.0
13A
0.0
13.4
3.0
13.4
0.0
13.4
3.0
25.3
0.0
13.4
3.0
25.3
0.0
13.4
3.0
25.3
0.01
13.4
3.0
25.3
Page Total
Btufhr
713
40
40
40
40
76
76
7s
1.1
Internal Gain Btufhr
Occupants 5 3 Occupants X 245 Btuh/occ. = 1.304
Equipment 1,772 Floor Area X 0.50 w/sgft = 3,024
Infiltration: 1.064 X 1.20 X 87.27 X 37 T 4,131
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,432
Latent Gain Btu/hr
Occupants 5•3 Occupants X 155 Btuh/occ. - 825
Infiltration: 4,771 X 1.20 X 87.27 X 0.00376 = 1,882
Air Sensible CFM ELA LAW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 8251
Ener Pro 7.2 by EnetvySoft User Number: 6712 ID: Pa e 40 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Custom Residence 6/27/2018
ROOM INFORMATION DESIGN CONDITIONS
Room Name Master Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,772.00 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF
e Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD�
=
=
=
=
=
=
=
=
=
Btu/hr
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
QQ
PP
NN
MM
LL
KK
AF
IAE
IAD
Orientation
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
Btu/hr
0.0
13.4
30
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
25.3
76
0.0
13.4
3.0
Page Total
683
Internal Gain Btu/hr
Occupants 5 3 Occupants X 245 Btuh/occ. = 1,304
Equipment 1, 772 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 1.20I X 87.27 X 37 = 4,131
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,4
Latent Gain _ _ Btu/hr
Occupants F 5 3 Occupants X _ _ 155 gtuh/occ. =
Infiltration: 4,771 X 1.20 X F87.27, X 0.00376 = C
Air Sensible CFM ELA. AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 825
Ener Pro 7.2 by Ener-qySoft User Number: 6712 ID: Paw 41 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Custom Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
Indoor Dry Bulb
Surfaces
Orientation
Master Outdoor Dry Bulb Temperature
1,772.00 ft2 Outdoor Wet Bulb Temperature
75 °F Outdoor Dailv Range:
Date
6/27/2018
Area U-Factor CLTD�
_ X X =
X X =
X X =
X X =
X X 1 =
X X�
X X -
X X -
X X -
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation
Area
GLF
Area
GLF
AC (E)
0.0 X
13.4
+
3.0
X
25.3 =
AB (E)
0.0 X
13.4
+
3.0
X
25.3 =
AU (S)
0.0 X
13.4
+
6.0
X
13.5 =
ZZ (S)
0.0 X
13.4
+
42.0
X
13.5 =
14 (S)
0.0 X
17.8
+
104.0
X
17.9 =
AA (S)
0.0 X
13.4
+
17.5
X
13.5 =
Z (S)
0.0 X
13.4
+
17.5
X
13.5 =
JJ (S)
0.0 X
13.4
+
3.0
X
13.5 =
HH (S)
0.0 X
13.4
+
3.0
X
13.5 =
Page Total
Internal Gain
Occupants 5•3 _ Occupants X 245 Btuh/occ.
1, 772 r Area X 0.501 w/sgft =
Equipment Floor -
Infiltration: 1.064 X 1.20 X 87 27 X 37 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
Occupants 5 3 Occupants X 155] Btuh/occ. _
Infiltration: _ 4,771 X 0 X 87.27 X 0.00376 =
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
7.2 bN Ener'gwSoft User Number: 6712 ID:
112 OF
78 OF
34 OF
Btu/hr
Btu/hr
76
76
81
566
1,8601
40
40
3,210
Btu/hr
1.304
3,024
4,131
20,432
Btu/hr
82!
1,882
82.9
7Q42of51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master
Outdoor Dry Bulb Temperature
112 OF
Floor Area '
1,772.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X F
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
_
Page Total
0
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
GG
(S) 0.0 X 13.4 +
3.0
X 13.5
= 40
FFF
(S) 0.0 X 13.4 +
3.0
X 13.5
= 40
EE
(S) 0.0 X 13.4 +
3.0
X 13.5
= 40
❑D
(S) 0.0 X 13.4 +
3.0
X 13.5
= 40
cc
(S) 0.0 X 13.4 +
3.0
X 13.5
= 40
BB
(S) 0.0 X 13.4 +
3.0
X 13.5
= 40
SS
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
TT
(IM 0.0 X 13.4 +
3.0
X 25.3
= 76
UU
(vo 0.0 X 13.4 +
3.0
X 25.3
= 76
Page Total
470
Internal Gain
Btu/hr
Occupants
5 3 Occupants X 245
Btuh/occ.
=
1.304
Equipment
1,772 Floor Area X 0.50
w/sgft
=
3,024
Infiltration: 1.064
X 1.20 X [ 87.27 X 37 =
4,131
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
20,432
Latent Gain
Btu/hr
Occupants
5.3 Occupants X 155
Btuh/occ.
=
625
Infiltration: 4,771
X 7.20 X 87.27 X 0.00376 =
1.882
Air Sensible
CFM ELA ❑VV
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
825
Ener.QyEro 7.2 by Enera Soft
User Number: 6712 ID:
Page 43 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,772.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (*) denote conduction through an interior surface to another room
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
vv
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
A/W
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
xx
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
YY
0.0 X 13A +
3.0
X 25.3
= 76
S
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
T
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
U
(IM 0.0 X 13.4 +
3.0
X 25.3
= 76
V
(lM 0.0 X 13.4 +
3.0
X 25.3
= 76
W
0.0 X 13.4 +
3.0
X 25.3
= 76
Page Total
683
Internal Gain
Btu/hr
Occupants
5 3 Occupants X 245
Btuh/occ.
=
1,304
Equipment
1.772 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 1.20 X 87.27 X 37 =
4.131
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
20,432
Latent Gain
Btu/hr
Occupants
53 Occupants X 155
Btuh/occ.
=
825
Infiltration: 4,771
X 1.20 X 87.27 X 0.00376 =
1,882
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT
HEAT GAIN FOR ROOM
825
EnerqyPro 7.2 by EnerqySoft
User Number: 6712 ID:
Page 44 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,772.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation _ Area U-Factor
CLTID
Btu/hr
X
X
-
X
X
-
X
X
-
X
X
-
X
X
=
X
X
-
X
X
-
_ X
X
=
X
X
-
Page Total
0
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
X (� 0.0 X X. 13.4 +
3.0
X 25.3
= 76
y (►� 0.0 X , 13.4 +
3.0
X 25.3
= 76
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
152
Internal Gain
Btu/hr
Occupants 5.3 Occupants X
245 Btuh/occ.
-
1,304
Equipment { 1,772 Floor Area X
0.50 w/ggft
_
3,024
Infiltration: 1.064 X 1.20 X �? X 37 =
4.131
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
20,432
Latent Gain
Btu/hr
Occupants 5 3 Occupants X j
155, Btuh/occ.
1.20
Infiltration: 4,771 X X 87.271 X 0.00376 =
1,882
Air Sensible CFM i [.A AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
825
EnenqyPro 7.2 by Ener Soft User Number: 6712
1D:
Page 45 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Custom Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Great living Area Outdoor Dry Bulb Temperature
Floor Area 2,064.00 ft2 Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range:
opaque Surfaces
R-38 Roof Attic R19 High Performa
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
'R-0 Interior Surface
Orientation
(N)
(N)
(E)
(SE)
(S)
(SI9
(VIO
Date
6/27/2018
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD1
=
=
=
=
=
=
=
=
=
2,064.0
0.0174
56.0
460.0
0.0690
23.0
306.5
0.0690
29.0
181.0
0.0690
33.0
360.6
0.0690
31.0
103.0
0.0690
26.0
96.0
0.0690
31.0
373.01
0.0690
33.0
500.0
0.3560
0.0
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1 Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation
Area
GLF
Area
GLF
M (N)
0.0 X
13.4
+
6.0
X
13.4 =
K (NE)
0.0 X
13A
+
12.0
X
19.9 =
7 (NE)
0.0 X
17.8
+
20.0
X
26.5 =
J (NE)
0.0 X
13.4
+
12.0
X
19.9 =
H (NE)
0.0 X
13.4
+
37.5
X
19.9 =
AT (E)
0.0 X
13A
+
3.0
X
25.3 =
AT (E)
0.0 X
13.4
+
3.0
X
25.3 =
AT (E)
0.0 X
13.4
+
3.0
X
25.3 =
AT (E)
0.0 X
13.4
+
3.0
X
25.3 =
Page Total
Internal Gain
Occupants fi•2 Occupants X 245 Btuh/occ. _
Equipment 2,064 Floor Area X E-L0.50 w/sgft
Infiltration: 1.064 X 120 X 101.65 X
Air Sensible CFM EILA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
Occupants 6.2 Occupants X F 155 Btuh/occ.
Infiltration: 4,771 X 1.20 X 101.65 X 0.00376 W
Air Sensible CFM ELA OW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
7.2 by EneravSoft User Number: 6712 ID
112 OF
78 OF
34 OF
Btu/hr
2,0121
613
412
771
185
5,
n238
76
76
76
2,135
Btu/hr
1,519
3.522
4,811
29,247
Btu/hr
961
2,192
961
7e 46 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Custom Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
Indoor ❑ry Bulb
Lie Surfaces
Great living Area Outdoor Dry Bulb Temperature
2,064.00 ft2 Outdoor Wet Bulb Temperature
75 OF Outdoor Daily Ranqe:
Orientation
Date
6/27/2018
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD�
=
=
=
=
=
=
=
_
=
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1 Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
AT
A
11
R
Q
P
N
Internal Gain
Orientation
(E)
(SE)
(SE)
(SE)
(VL9
W
(�M
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
13.4
3.0
25.3
0.0
13.4
11.7
18.0
0.0
17.8
36.0
24.0
0.0
13.4
11.7
18.0
230.0
17.8
0.0
33.8
9.0
13.4
0.0
25.3
9.0
13.4
0.0
25.3
9.0
13.4
0.0
25.3
9.0
13.4
0.0I
25.3
Page Total
Occupants 6.2 Occupants X 245 Btuh/occ. _
Equipment 2,064Floor Area X 0.50 w/sgft =
Infiltration: 1.064 X 1.20� X L 101.65 X 37 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
Occupants 6 2 Occupants X 155] Btuh/occ. _
Infiltration: Fi�4,771 X 1.20 X 101.65 X 0.00376 =
Air Sensible CFM ELA ❑W
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
112 OF
78 OF
34 OF
Btu/hr
0
Btu/hr
76
211
211
4,098
121
121
121
121
5, 944
Btu/hr
1.519
3,522
4, 811
29.247
Btu/hr
961
2,192
961
7.2 by EnemySoft User Number. 6712 ID.
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project name
Custom Residence
ROOM INFORMATION TDESIGN CONDITIONS
Room Name
Floor Area
Indoor Dry Bulb T
Surfaces
Great living Area Outdoor Dry Bulb Temperature
2,064.00 ft2 Outdoor Wet Bulb Temperature
75 OF Outdoor Daily Range:
Orientation
Date
6/27/2018
Area
X
X
X
X
X
X
X
X
U-Factor
f CLTD'
X _
X =
X =
X =
X =
X _
X =
X =
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
10
9
8
L
23
13
12
Internal Gain
Orientation
(IM
(tM
(KO
(tM
(IM
(tM
(IM
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
0.5
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
35.5
17.8
33 8
60.0
13.4
0.0
25.3
20.0
13.4
0.0
25.3
6.0
13.4
0.0
25.3
15.7
17.8
4.3
33.8
117.0
17.8
0.0
33.8
67.1
17.8
0.9
33.8
Page Total
Occupants 6.2 Occupants X �245 Btuh/occ.Epuipment 2,064 Floor Area X w/sgft =
Infiltration: F 1.064 X 1.20 X L 101.E X 37 =
Air Sensible CFtN E L A AT
112 OF
78 OF
34 OF
Btu/hr
Btu/hr
649
805
268
8111
H12, 085
,225
5,
Btu/hr
1,519
1 4,8111
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,247
Latent Gain Btu/hr
Occupants 6.2 Occupants X F 1551 gtuh/occ. = 961
Infiltration: 4,771 X 1.20 X 101.65 X 0.00376 2,192
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 961
FA4
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name dining
Outdoor Dry Bulb Temperature
112 OF
Floor Area 480.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor CLTD'
Btu/hr
R30 (N) 480.0 X 0.0360 X
56.0 =
968
R-21 Wall (NE) 358.0 X 0.0690 X
29.0 =
716
R-21 Wall (SE) 183.5 X 0.0690 X
31.0 =
393
R-21 Wall (SVl7 199.7 X 0.0690 X
31.0 =
427
R-21 Wall (NVIO 96.0 X 0.0690 X
30.2 =
200
'R-0 Interior Surface 480.0 X 0.3560 X
0.0 =
0
X X
=
X X
=
X X
=
Page Total
2,704
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
G (NE) 0.0 X 13.4 + 6.0
X 19.9
= 119
F (NE) 0.0 X 13.4 + 16.0
X 19.9
= 318
2 (SE) 0.0 X 17.8 + 76.5
X 24.0
= 1,839
C (SW) 0.0 X 13.4 + 60.3
X 18.0
= 1,087
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
3,36
Internal Gain
Btu/hr
Occupants 14 Occupants X 245 Btuh/occ.
=L
353
Equipment 480 Floor Area X 0.50 w/sgft
=
819
Infiltration: 1.064 X 1.20 X �23.64 X 37 =
1,119
Air Sensible CFM CLp. AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
8,357
Latent Gain
Btu/hr
Occupants 14 Occupants X 155 Btuh/occ.
=
223
1.20
Infiltration: 4,771 X X 23.64 X 0.00376 =
510
AirSensibte CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
223
EnerqyPro 7.2 b Ene Soff User Number: 6712 JD_
Pa a 49 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Custom Residence 612712018
ROOM INFORMATION DESIGN CONDITIONS
Room Name Second Floor Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,187.00 ftZ Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 °F Outdoor Daily Range: 34 OF
I Onaoue Surfaces
R-38 Roof Aitic R19 High Performa
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R30 W/o CRAWLSPACE
"R-0 hiterior Surface
Orientation
(N)
(N)
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
1.187.0
0.0174
56.0
186.0
0.0690
23.0
890.5
0.0690
29.0
190.0
0.0690
31.0
780.0
0.0690
31.0
284.0
0.0690
33.0
96.0
0.0690
30.2
822.0
0.0340
19.0
255.0
0.3560
0.0!
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
BD
BC
BA
AZ
AY
AX
A
AV
BJ
Internal
Orientation
(N)
(NE)
(NE)
(NE)
(NE)
(NE)
(NE)
(SE)
(SIM
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
13A
10.0
13.4
0.0
13.4
10.0
19.9
0.0
13.4
6.0
19.9
0.0
13.4
25.0
19.9
0.0
13.4
6.0
19.9
0.0
13.4
7.5
19.9
0.0
13.4
15.0
19.9
0.0
13.4
6.0
18.0
0.0
13.4
8.0
Page Total
3.6 Occupants X 2451 Btuh/occ. _
1,187 Floor Area X 0.50i W/sgft
Infiltration: 1.064 X 1.20 X 58.46 X 37
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
3 s ] Occupants X 1 155I Btuh/occ. W
Infiltration: 4,771 X 1.20 X 58.46 X 0.00376 =
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
7
User Number. 6712
Btu/hr
1,157
1
Btu/hr
134
199
119
496
119
149
29a
108
1,766
Btu/hr
873
2,026
2,767
17,945
Btu/hr
553
1,261
553
e 50 of 51
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
6/27/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Second Floor
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,187.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
X
X
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
SH
(SIM 0.0 X 13.4 +
8.0
X 18.0
= 144
BG
(SIM 0.0 X 13.4 +
8.0
X 18.0
= 144
BF
(SIM 0.0 X 13.4 +
8.0
X 18.0
= 144
BE
(SIM 0.0 X 13.4 +
8.0
X 18.0
= 144
30
(IM 0.0 X 17.8 +
96.0
X 33.8
= 3,250
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
3,625
Internal Gain
Btu/hr
Occupants
3 6 Occupants X 245,
Btuh/occ.
=
873
Equipment
1,187 Floor Area X 0.50
w/sgft
=
2,026
Infiltration: 1.064
X 1.20 X 58.45 X 3i =
2,767
Air Sensible
CFM ELA 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
17,945
Latent Gain
Btu/hr
Occupants
3 6 Occupants X 155
Btuh/occ.
=
553
Infiltration: 4,771
X 1.20 X 58.46 X 0.00376 =
1,261
Air Sensible
CFM ELA ❑w
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
553
Enerq Pro 7.2 by Ener ySoft
User Number: 6712 ID:
Page 51 of 51