BRES2017-0192 Revision 2 Title 24i BUILDING ENERGY ANALYSIS REPORT PROJECT: Hicks Residence 80957 Via Pessaro - The Hideaway La Quinta, CA 92253 Project Designer: Brock J. Payton, Inc. 8391 Beverly Blvd., Suite 482 Los Angeles, CA 90048 CITY OF LA QUINTA ((310) 720-6589 1 BUILDING DIVISION Report Prepared by: Tim Scott L Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #8 Palm Desert, CA 92260 (760) 200-4780 Job Number: Date: 8/17/2018 REVIEWED FOR CODE COMPLIANCE O* cE AUG 2 8 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT a— The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software—www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 18 Form MF-1 R Mandatory Measures Summary 21 HVAC System Heating and Cooling Loads Summary 25 Zone Load Summary 29 Room Load Summary 33 Room Heating Peak Loads 37 Room Cooling Peak Loads 42 CER' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCI THOD Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-1 7. ribd 1 6x -PRF-01 Page 1 of 15 GENERAL INFORMATION 01 Project Name I Hicks Residence 02 Calculation Description Title 24 Analysis 03 Project Location 80957 Via Pessaro - The Hideaway 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 8577 15 Number of Zones 5 16 Slab Area (ftZ) 8577 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) n/a 21 Glazing Percentage (%) 35.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.85 8.25 -5.40 -189.5% Space Cooling 83.31 75.07 8.24 9.9% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 1.66 7.14 -5.48 -330.1% Photovoltaic Offset — -14.42 14.42 — Compliance Energy Total 88.48 76.70 11.78 13.3% Registration Number: 217-P010256607F-000-000-0000000-0000 Registration Daterrime: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER7 ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD Project Name: Hicks Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Input File Name: Hicks Res-Payton-1 7. ribd 1 6x C-PRF-01 Page 2 of 15 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 47.7 48.9 10.5 38.4 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules ENERGY DESIGN RATING PV SYSTEM INPUTS - DETAILED DC System Size (kWdc) Module Type CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) 5.6 Standard ❑ 180 deg 0.0 0.0 97 • PV System offsets 22% of the total proposed design kTDV/ft-yr REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • PV System: 5.6 kWdc • Cool roof • Window overhangs and/or fins Registration Number: 217-P010256607F-000-000-0000000-0000 Registration Date/Time: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER1 ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD C PRF-01 Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Page 3 of 15 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Hicks Residence 8577 1 4 5 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Bdrm Zone Conditioned HVAC-Masterl 1467 11.8 DHW Sys 1 n/a Great/Kit/Lou./Off Zone Conditioned HVAC-Living2 4443 11.8 DHW Sys 1 n/a Casita Zone Conditioned HVAC-Casita3 967 11.8 DHW Sys 1 n/a Bdrm 1 Zone Conditioned HVAC-Casita3 385 11.8 DHW Sys 1 n/a Garage Zone Conditioned HVAC-Garage4 1315 1 10 DHW Sys 1 n/a Registration Number: 217-Po10256607F-000-000-0000000-0000 Registration Date/Time: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCF THOD Project Name: Hicks Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Input File Name: Hicks Res-Payton-17.dbdl6x -PRF-01 Page 4 of 15 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) N Wall Master Bdrm Zone R-21 Wall 0 Front 30 0 90 S Wall Master Bdrm Zone R-21 Wall 180 Back 368 186.399 90 W Wall Master Bdrm Zone R-21 Wall 270 Right 616 71.5781 90 Interior Surface Master Bdrm Zone»Great/Kit/Lou./Off Zone R-0 Interior Surface n/a n/a 272 0 n/a Interior Surface 2 Master Bdrm Zone R-0 Interior Surface n/a n/a 286 0 n/a Interior Surface 3 Master Bdrm Zone»Casita Zone R-0 Interior Surface n/a n/a 190 0 n/a Roof Master Bdrm Zone R-38 Roof W/R-13 n/a n/a 1207 n/a n/a N Wall 2 Great/Kit/Lou./Off Zone R-21 Wall 0 Front 1408 456.2 90 E Wall Great/Kit/Lou./Off Zone R-21 Wall 90 Left 1415 339.13 90 S Wall 2 Great/Kit/Lou./Off Zone R-21 Wall 180 Back 1554 846.3 90 W Wall 2 Great/Kit/Lou./Off Zone R-21 Wall 270 Right 943 510.2 90 Interior Surface 4 Great/Kit/Lou./Off Zone —Master Bdrm Zone R-0 Interior Surface n/a n/a 272 0 n/a Interior Surface 5 Great/Kit/LouJOff Zone R-0 Interior Surface nia n/a 286 0 n/a Roof 2 Great/Kit/Lou./Off Zone R-38 Roof W/R-13 n/a n/a 3320 n/a n/a N Wall 3 Casita Zone R-21 Wall 0 Front 550 35 90 E Wall 2 Casita Zone R-21 Wall 90 Left 320 205.2 90 S Wall 3 Casita Zone R-21 Wall 235 - specify - 170 33.3 90 W Wall 3 Casita Zone R-21 Wall 270 Right 350 92.6 90 Interior Surface 6 Casita Zone»Master Bdrm Zone R-0 Interior Surface n/a n/a 190 0 n/a Interior Surface 7 Casita Zone»Bdrm 1 Zone R-0 Interior Surface n/a n/a 90 0 n/a Roof 3 Casita Zone R-38 Roof W/R-13 n/a n/a 862 n/a n/a E Wall 3 Bdrm 1 Zone R-21 Wall 90 Left 253 174.2 90 Interior Surface 8 Bdrm 1 Zone>>Great/Kit/Lou./Off Zone R-0 Interior Surface n/a n/a 286 0 n/a Interior Surface 9 Bdrm 1 Zone»Master Bdrm Zone R-0 Interior Surface n/a n/a 286 0 n/a Interior Surface 10 Bdrm 1 Zone»Casita Zone R-0 Interior Surface n/a n/a 90 0 n/a Roof 4 Bdrm 1 Zone R-38 Roof W/R-13 n/a n/a 385 n/a n/a N Wall 4 Garage Zone R-21 Wall 0 Front 358 84 90 E Wall 4 Garage Zone R-21 Wall 90 Left 593 352 90 Registration Number: 217-Po10256607F-000-000-0000000-0000 Registration DatelTme: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER7 ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCr THOD Project Name: Hicks Residence Calculation Datefrime: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribdl6x -PRF-01 Page 5 of 15 S Wall 4 Garage Zone R-21 Wall 180 Back 158 1 0 90 W Wall 4 Garage Zone R-21 Wall 270 Right 221 24 90 Interior Surface 11 Garage Zone»Great/Kit/Lou./Off Zone R-0 Interior Surface n/a n/a 272 0 n/a Roof 5 Garage Zone R-38 Roof W/R-13 n/a I n/a 1315 Na n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ftz) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Flat Roof Master Bdrm Zone R-38 Flat Roof W/ R-10 Right 260 0 1 0.61 0.92 Yes Flat Roof 2 Great/Kit/Lou./Off Zone R-38 Flat Roof W/ R-10 Front 360 16 1 0.61 0.92 Yes Flat Roof 3 Casita Zone R-38 Flat Roof W/ R-10 Front 105 0 1 0.61 0.92 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Bdrm Zone Attic RoofMaster Bdrm Zone Ventilated 3 0.22 0.92 Yes Yes Attic Great/Kit/Lou./Off Zone Attic RoofGreat/Kit/Lou`/Off Zone Ventilated 1 0.22 0.92 Yes Yes Attic Casita Zone Attic RoofCasita Zone Ventilated 3 0.22 0.92 Yes Yes Attic Bdrm 1 Zone Attic RoofBdrm 1 Zone Ventilated 1 0.22 0.92 Yes Yes Attic Garage Zone Attic RoofGarage Zone Ventilated 3 0.22 0.92 Yes Yes Registration Number: 217-P010256607F-000-000-0000000-0000 Registration DatefTime: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER- 'ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCr THOD Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribd16x -PRF-01 Page 6 of 15 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading D11 Window S Wall (Back-180) 14.0 10.0 1 140.0 0.49 0.23 Insect Screen (default) W15 Window S Wall (Back-180) -- - 1 35.6 0.60 0.16 Insect Screen (default) W14 Window S Wall (Back-180) 4.7 2.3 0.999 10.8 0.35 0.24 Insect Screen (default) W16 Window W Wall (Right-270) 3.4 10.0 1.029 35.0 0.35 0.24 Insect Screen (default) W13 Window W Wall (Right-270) 5.5 2.3 1.004 12.7 0.35 0.24 Insect Screen (default) W12 Window W Wall (Right-270) 3.3 2.3 1.001 7.6 0.35 0.24 Insect Screen (default) W11 Window W Wall (Right-270) 3.3 2.3 1.001 7.6 0.35 0.24 Insect Screen (default) W10 Window W Wall (Right-270) 3.8 2.3 0.995 8.7 0.35 0.24 Insect Screen (default) D09 Window N Wall 2 (Front-0) 5.5 10.0 1 55.0 0.49 0.23 Insect Screen (default) W27 Window N Wall 2 (Front-0) 9.0 11.0 1 99.0 0.35 0.24 Insect Screen (default) D02 Window N Wall 2 (Front-0) 8.0 11.0 1 88.0 0.49 0.23 Insect Screen (default) W25 Window N Wall 2 (Front-0) 6.8 11.0 1 74.8 0.35 0.24 Insect Screen (default) W24 Window N Wall 2 (Front=0) - - 1 19.0 0.35 0.24 Insect Screen (default) W23 Window N Wall 2 (Front-0) -- 1 1 19.0 0.35 0.24 Insect Screen (default) W26 Window N Wall 2 (Front 0) - - 1 20.4 0.35 0.24 Insect Screen (default) W28 Window N Wall 2 (Front-0) - - 1 27.0 0.35 0.24 Insect Screen (default) D05 Wndow N Wall 2 (Front-0) 1 45.0 0.49 0.23 Insect Screen (default) W33 Window N Wall 2 (Front-0) - 1 9.0 0.35 0.24 Insect Screen (default) W29 Window E Wall (Left-90) -- 1 19.8 0.35 0.24 Insect Screen (default) W29 2 Window E Wall (Left-90) - - 1 19.8 0.35 0.24 Insect Screen (default) W29 3 Window E Wall (Left-90) - 1 19.8 0.35 0.24 Insect Screen (default) D18 Window E Wall (Left-90) -- - 1 27.0 0.74 0.14 Insect Screen (default) W18 Window E Wall (Left-90) 6.1 9.5 0.497 28.8 0.35 0.20 Insect Screen (default) D17 Window E Wall (Left-90) -- - 1 24.0 0.74 0.14 Insect Screen (default) W17 Window E Wall (Left-90) - -- 1 20.3 0.60 0.16 Insect Screen (default) D13 Window E Wall (Left-90) 6.3 12.0 1 75.6 0.49 0.23 Insect Screen (default) W20 Window E Wall (Left-90) 6.1 9.5 1 1.381 1 80.0 0.35 0.24 Insect Screen (default) D16 Window S Wall 2 (Back-180) 15.8 12.0 1 189.6 0.38 1 0.18 Insect Screen (default) D14 Window S Wall 2 (Back-180) 33.5 12.0 1 402.0 0.49 1 0.23 Insect Screen (default) Registration Number: 217-P010256607F-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Dateffime: 2018-08-17 13:36:40 Report Version - CF1 R-06282018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-08-17 13:31:14 CER? ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribd16x C •PRF-01 Page 7 of 15 D12 Window S Wall 2 (Back-180) 15.3 12.0 1 183.6 0.57 0.16 Insect Screen (default) W21 Window S Wall 2 (Back-180) - -- 1 26.1 0.60 0.16 Insect Screen (default) D04 Window S Wall 2 (Back-180) - 1 45.0 0.49 0.23 Insect Screen (default) W22 Window W Wall 2 (Right-270) - ---- 1 19.0 0.35 0.24 Insect Screen (default) D03 Window W Wall 2 (Right-270) 15.0 10.0 1 1 150.0 0.57 1 0.20 Insect Screen (default) D15 Window W Wall 2 (Right-270) 13.3 12.0 1 159.6 0.38 0.18 Insect Screen (default) W31 Window W Wall 2 (Right-270) ---- --- 1 11.0 0.35 0.24 Insect Screen (default) W32 Window W Wall 2 (Right-270) ---- -- 1 11.0 0.35 0.24 Insect Screen (default) D16 2 Window W Wall 2 (Right-270) 13.3 12.0 1 159.6 0.38 0.18 Insect Screen (default) Skylight Skylight Flat Roof 2 (Front-0) 1 16.0 0.39 0.29 W06 Window N Wall 3 (Front-0) 1 17.5 0.35 0.20 Insect Screen (default) W05 Window N Wall 3 (Front-0) - -- 1 17.5 0.35 0.20 Insect Screen (default) D06 Window E Wall 2 (Left-90) - 1 90.0 0.50 0.23 Insect Screen (default) D07 Window E Wall 2 (Left-90) -- 1 115.2 0.50 0.23 Insect Screen (default) W30 Window S Wall 3 (- specify --235) - - 1 33.3 0.35 0.24 Insect Screen (default) D10 Window W Wall 3 (Right-270) - - 1 77.6 0.50 0.23 Insect Screen (default) W08 Window W Wall 3,(Right-270) - - 1 7.5 0.48 0.19 Insect Screen (default) W09 Window W Wall 3 (Right-270) - - 1 7.5 0.48 0.19 Insect Screen (default) W29 4 Window E Wall 3 (Left-90) -- 1 19.8 0.35 0.24 Insect Screen (default) W29 5 Window E Wall 3 (Left-90) - 1 19.8 0.35 0.24 Insect Screen (default) W29 6 Window E Wall 3 (Left-90) - 1 19.8 0.35 0.24 Insect Screen (default) W29 7 Window E Wall 3 (Left-90) - 1 19.8 0.35 0.24 Insect Screen (default) D08 Window E Wall 3 (Left-90) - -- 1 95.0 0.50 0.23 Insect Screen (default) W01 Window N Wall 4 (Front-0) - 1 21.0 0.35 0.24 Insect Screen (default) W02 Window N Wall 4 (Front-0) - - - 1 21.0 0.35 0.24 Insect Screen (default) W03 Window N Wall 4 (Front-0) - -- 1 21.0 0.35 0.24 Insect Screen (default) W004 Window N Wall 4 (Front-0) - -- 1 21.0 0.35 0.24 Insect Screen (defaul-] t) Registration Number: 217-P010256607F-000-000-0000000-0000 Registration DateRme: 2018-03-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CERT ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD Project Name: Hicks Residence Calculation Daterrime: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribd16x C PRF-01 Page 8 of 15 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor D31 E Wall 24.0 0.50 d19 E Wall 4 64.0 0.08 d20 E Wall 4 144.0 0.08 d21 E Wall 4 144.0 0.08 d21 a W Wall 4 24.0 1.00 � CaICERTS, Inc. HERS PROVIDER Registration Number: 217-Po10256607F-000-000-0000000-0000 Registration Date/Time: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CERI ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribdl6x -PRF-01 Page 9 of 15 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up D11 12 0.1 12 12 0 0 0 0 0 0 0 0 0 W14 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W16 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W13 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W12 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W11 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W10 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D09 12 0.1 12 12 0 0 0 0 0 0 0 0 0 W27 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D02 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W25 4 0.1 O N 0 0 0 0 0 0 W18 8 0.1 8 8 0 0 "Ik:4 0 0 0 0 0 0 D13 23 0.1 '3 0 0 4.4 0 0 0 0 W20 8 0.1 sP--A8 8 of j fl 0 0 0 0 0 D16 12 0.1 12 12 0 0 0 0 0 0 0 0 0 D14 23 0.1 23 23 0 0 0 0 0 0 0 0 0 D12 8 0.1 8 8 0 0 0 0 0 0 0 0 0 D03 12 0.1 12 12 0 0 0 0 0 0 0 0 0 D15 8 0.1 8 8 0 0 0 0 0 0 0 0 0 D162 12 0.1 12 12 0 0 0 0 0 0 0 0 0 Registration Number: 217-P010256607F-000-000-0000000-0000 Registration DateRme: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER" ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribdl6x -PRF-01 Page 10 of 15 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Bdrm Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof W/R-13 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-38/2x12 Roof Deck: Wood Siding/sheathing/decking R-38 Flat Roof W/ R-10 Cathedral Ceilings Wood Framed Ceiling 2x12 @ 16 in. O.C. R 38 0.030 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Interior Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd Attic RoofGreat/Kit/Lou./Off 2x4 Top -Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCasita Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofBdrm 1 Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing., Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGarage Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Registration Number: 217-Po10256607F-000-000-0000000-0000 Registration Date/Time: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCr THOD Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-1 7.ribdl 6x -PRF-01 Page 11 of 15 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value 8: Depth Carpeted Fraction Heated Slab -on -Grade Master Bdrm Zone 1467 93 None 0.8 No Slab -on -Grade 2 Great/Kit/Lou./Off Zone 4443 74 None 0.8 No Slab -on -Grade 3 Casita Zone 967 136 None 0.8 No Slab -on -Grade 4 Bdrm 1 Zone 385 24 None 0.8 No Slab -on -Grade 5 Garage Zone 1315 132 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss I First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Large Storage 2 100 0.99 TE 85,000 Btu/hr R-0/R-0 0.03 n/a n/a n/a Registration Number: 217-Po10256607F-000-000-0000000-0000 Registration DateMme: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER- 'ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCr Project Name: Hicks Residence Calculation Description: Title 24 Analysis THOD Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Input File Name: Hicks Res-Payton-17.ribd16x -PRF-01 Page 12 of 15 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC-Masterl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC-Living2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC-Casita3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC-Garage4 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 None - none - HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntHFurnace 1 80 AFUE Heating Component 2 CntHFurnace 3 80 AFUE Heating Component 3 CntHFurnace 1 80 AFUE HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 4 Ductless MiniSplitHeatPump 1 9.5 40000 24000 18.3 9.3 Not Zonal Single Speed Heat Pump System 4-hers-cool HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13.2 16.5 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 3 13.2 16.5 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 13.2 16.5 Not Zonal Single Speed Cooling Component 3-hers-cool Registration Number: 217-P010256607F-000-000-0000000-0000 Registration Date[Time: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER" ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD C-PRF-01 Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Page 13 of 15 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-1 7. ribd 1 6x HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Verified Refrigerant Name Verified Airflow Airflow Target Verified EER Verified SEER Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Heat Pump System 4-hers-cool Not Required n/a Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Specified Lower Leakage 8 Attic None Air Distribution System Air Distribution System 1 y DuctsAttic Target 1-hers-dist Specified Lower Leakage 8 Attic None Air Distribution System Air Distribution System 2 y DuctsAttic Target 2-hers-dist Specified Lower Leakage 8 Attic None Air Distribution System Air Distribution S stem 3 y DuctsAttic Target 3-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 -03 ' 04 05 06 07 08 Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low -leakage Name Verification Target (%) Location Design Ducts Ducts Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Registration Number: 217-P010256607F-000-000-0000000-0000 Registration Date/Time: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCC Project Name: Hicks Residence Calculation Description: Title 24 Analysis THOD Calculation Daterrime: 13:29, Fri, Aug 17, 2018 Input File Name: Hicks Res-Payton-17.ribd16x C-PRF-01 Page 14 of 15 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.52 HVAC Fan 2-hers-fan Required 0.52 HVAC Fan 3-hers-fan Required 0.52 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 123 0.25 Default 0 Required � CaICERTS,i Inca Registration Number: 217-P010256607F-000-000-0000000-0000 Registration Dateffime: 2018-08-17 13:36:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-08-17 13:31:14 CER' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE THOD C-PRF-01 Project Name: Hicks Residence Calculation Date/Time: 13:29, Fri, Aug 17, 2018 Page 15 of 15 Calculation Description: Title 24 Analysis Input File Name: Hicks Res-Payton-17.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: �G+vl��G'6Gri Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-08-17 13:36:40 Address: CEAMERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2018-08-17 13:36:40 Address: License: 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-Po10256607F-000-000-0000000-0000 Registration Dateffime: 2018-08-17 13:36:40 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2018-08-17 13:31:14 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type m Single Family ❑ Addition Alone Date Hicks Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 811712018 Addition # of Units Project Address California Energy Climate Zone Total Cond. Floor Area 80957 Via Pessaro - The Hideaway La Q CA Climate Zone 15 8,577 n/a 1 INSULATION Area Construction Type Cavity ft Special Features Status Roof Wood Framed Attic R 38 7,089 Add=R-13.0 Cool Roof New Roof Wood Framed Rafter R 38 709 Cool Roof New Wall Wood Framed R 21 5,897 New Slab Unheated Slab -on -Grade no insulation 8,577 Perim = 459' New Demising Wood Framed - no insulation 1,768 New Demising Wood Framed no insulation 286 Existing Door Opaque Door - no insulation 24 New Demising Wood Framed - no insulation 90 Existing FENESTRATION Orientation Area(ft) Total Area: 3,026 Glazing percentage: U-Fac SHGC Overhang 35.3 % New/Altered Average U»Factor. Sidefins Exterior Shades 0.45 Status Rear (S) 140.0 0.490 0.23 12.0 none Bug Screen New Rear (S) 61.7 0.600 0.16 none none Bug Screen New Rear (S) 10.8 0,350 0.24 4.0 none Bug Screen New Right (W) 71.6 0.350 0.24 4.0 none Bug Screen New Skylight 16.0 0.390 0.29 none none None New Front (N) 55.0 0.490 0.23 12.0 none Bug Screen New Front (N) 173.8 0.350 0.24 4.0 none Bug Screen New Front (N) 88.0 0.490 0.23 4.0 none Bug Screen New Front (N) 178.4 0.350 0.24 none none Bug Screen New Front (N) 45.0 0.490 0.23 none none Bug Screen New Left (E) 138.6 0.350 0.24 none none Bug Screen New Left (E) Left (E) Left (E) HVAC SYSTEMS Qt . Heating 1 Central Furnace 51.0 28.8 20.3 0.740 0.350 0.600 Min. Eff 80% AFUE 0.14 none 0.20 8.0 0.16 none Cooling Split Air Conditioner none none none Min. Eff 16.5 SEER Bug Screen Bug Screen Bug Screen Thermostat Setback New New New Status New 3 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 16.5 SEER Cooling Duct Location Setback Duct R-Value New Status HVAC-Master Ducted Ducted Attic 8.0 New HVAC-Living HVAC-Casita Ducted Ducted Ducted Ducted Attic Attic 8.0 8.0 New New WATER HEATING 2 Larae Storage Gas Gallons Min. Eff Distribution 100 0.99 Standard Status New Number: 6712 ID page 16 of RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Hicks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 811712018 Project Address 80957 Via Pessaro - The Hideaway La Q. California Energy Climate Zone ' Total Cond. Floor Area CA Climate Zone 15 8,577 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area ft Special Features Status Demising Wood Framed no insulation 286 Existing Demising Wood Framed no insulation 90 Existing Door Opaque Door no insulation 352 Add=R-12.0 New Door Opaque Door no insulation 24 New FENESTRATION Orientation Area f 2 I Total Area: 3.026 Glazing Percentage: 35.3 % U-Fac SHGC Overhang Sidefins NewfAltered Avers a U-Factor: 0-45 Exterior Shades Status Left (E) 75.6 0.490 0.23 23.0 none Bug Screen New Left (E) 80.0 0.350 0.24 8.0 none Bug Screen New Rear (S) 189.6 0.380 0.18 12.0 none Bug Screen New Rear (S) 402.0 0.490 0.23 23.0 none Bug Screen New Rear (S) 183.6 0.570 0.16 8.0 none Bug Screen New Rear (S) 45.0 0.490 0.23 none none Bug Screen New Right (W) 41.0 0.350 0.24 none none Bug Screen New Right (W) 150.0 0.570 0.20 12.0 none Bug Screen New Right (W) 159.6 0.380 0.18 8.0 none Bug Screen New Right (W) 159.6 0.380 0.18 12.0 none Bug Screen New Front (N) 35.0 0.350 0.20 none none Bug Screen New Left (E) 300.2 0.500 0.23 none none Bug Screen New Right (SW) 33.3 0.350 0.24 none none Bug Screen New Right (W) 77.6 0.500 0.23 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 18.3 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC-Garage Ductless / with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerovPro 7.2 by EneravSoft User Number: 6712 ID: Paw 19 of 49 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Hicks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 811712018 Project Address 80957 Via Pessaro - The Hideaway La Q California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,577 Addition n/a # of Units 1 INSULATION Area Construction Type Cavity ft Special Features Status FENESTRATION Total Area: 3,026 Glazing Percentage: 35.3 % New/Altered Average U-Factor: 0.45 Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status Right (W) 15.0 0.480 0.19 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Coofin2 Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ene Pro 7.2 by EnergySoft User Number.- 6712 ID: Page 20 of 49 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Revised 04/20171 Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011: § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for com liance and must be caulked and/or weatherstrip ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 it when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling .' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as art of a heated slab floor, meet the requirements of § 110.8 . Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: requirement also applies to controlled ventilation crawls ace for buildings complying with the exoe Lion to § 1150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of Q.58; or the weighted average U-factor of all fenestration must not exceed 0.58: Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is eaui ped with a readily accessible, operable, and fi ht-fittin damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building. are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heathis higher than the cut-off temperature for supplements heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 11Q.3 c 5. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs § 110.3(c)7: or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exempt); and pool and spa heaters: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design eondiiions specified in § 150.0 h 2. el 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances, Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier, Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and coaling system line Insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casin2 or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution i in for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover, The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class 11 vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacit of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150 0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems, Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openin s to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, ressure drop, and labeling requirements of § 150.0 m 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing, Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space oonditioning sys Ism must also demonstrate airflow �- 350 CFM per ton of nominal cooling capadly through the return grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole-buildingventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing,in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built -tip connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run oni during off - _peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping,filters, and valves.' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements § 110.9: of 110.9., JAB High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must § 110.9(e): be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fans eed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than § 150.0(k)1 D: 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) § 150.0(k)1 F: must meet the applicable requirements of § 150.0(k).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually § 150.0(k)2C: switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k)2E: 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if [l meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(01 and all other requirements in § 150.0 k 2. Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it § 150.0(k)21: provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0 k 2. 2016 Low -Rise Residential Mandatory Measures Summary § 150,0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in 110.9,130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0(k)30 must comply with the applicable requirements in §5 110.9,130.0,130.2,130.4,140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in 110.9, 130A 130.2,130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined accordin2 to 5 130.0 c . § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential gwages in §§ 110:9.130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: !. Comply with the applicable requirements in §§ 110.9, 130.0,130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the reg urem ents of § 110.10 b 1hroug h § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof § 110.10(b)3A: mounted eauioment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured In the vertical plane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main servicepanel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.1 0c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Hicks Residence System Name HVAC-Master ENGINEERING CHECKS Number of Satems Heatinq Svstem Total Cooli SYSTEM LOAD 1 89,000 Total Room Loads 89,000 Return Vented Lighting 60.7 Return Air Ducts Return Fan 58,000 Ventilation Total Output Btuh 58,000 Supply Fan Total Output Tons 4.8 Supply Air Ducts Total Output (Btuh/sgft) 39.5 Total Output s ftrron 303.5 TOTAL SYSTEM LOAD Air Svstem Date 8/17/2018 Floor Area 1,467 COOLING PEAK COIL HTG. PEAK bCCOIL FM Sensible Latent I CFM Sensible 780 16.234 1.923 414 15,251 0 937 750 0 0 0 0 Q 0 0 0 937 18,108 1.923 0 750 16,751 CFM per System Airflow (cftnl 2,000 2,000 HVAC EQUIPMENT SELECTION Carrier 24ANB760-58PH**l 10-20 Airflow cfmfs ft 1.36 Airflow cfm/Ton 413.8 Outside Air %) Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air cfmis ft 0.00 I Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heat 26 OF 70 OF 105 IF 105 OF 43,180 5,8491 89,000 43,180 5.849 89,000 Aug 3 PMi I Jan 1 AM i Outside Air NTI ` ! -_.0 0 cfm Heating Coil Supply Fan 2,000 cfm 105 °F 70 OF ROOM 0 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62°F 55/54°F 55/54°F Outside Air 0 cfm Cooling Coil Supply Fan 55 / 54 OF 2,000 cfm 47.2 % ROOM 75 / 62 IF 75 162 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Hicks Residence Date 8/17/2018 System Name HVAC-Living Floor Area 4,443 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 3,406 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 70,193 5.825 1,877 68,866 Total Output Btuh 267,000 0 Output Btuh/s ft 60.1 4.052 3,384 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 174,000 0 , 225 0 Total Output Tons 14.5 4,052 3,384 Total Output Btuh/s ft 39.2 Total Output s ft/Ton 306.4 78,27977E775 75.635 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 6,000 Carrier 24ANB760-58PH**110-20 130,309 16,912 267,000 Airflow cfm/s ft 1.35 Airflow cfm/Ton 413.8 Outside Air % 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 130.309 16,912 267,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF op Outside Air 0 cfm 69 OF 69 OF 105 OF 105 IF 9 ��C1lll� Heating Coil Supply Fan 6,000 cfm 104 IF ROOM 0 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 0 cfm 76 / 62 OF 76/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 6,000 cfm �lll 56 / 54 OF 47 2 % ROOM 75 / 62 IF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Hicks Residence 8/17/2018 System Name Floor Area HVAC-Casita 1,352 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1.248 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK Sensible 25,642 0 1,480 0 0 0 1,480 28,602 COIL HTG. Latent CFM 1,772 647 0 0 1,772 PEAK Heating System Sensible Output per System 89,000 23,739 Total Output Btuh 89,000 Output Btuhls ft 65.8 1.167 Cooling System 0 Output per System 58,000 0 Total Output Btuh 58,000 0 Total Output Tons 4•8 1.167 Total Output Btuhls ft 42.9 Total Output s ft/Ton 279.7 26,072 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760-58PH**l10-20 43,580 5,484 89,000 Airflow cfm/s ft 1.48 Airflow(cfm/Ton) 413.8 Outside Air °I° 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) 43,580 5,48a 89,000 0.00 Outside Air cfm/s ft I TIME OF SYSTEM PEAK Jan 1 AM Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 IF 105 IF 105 OF Outside Air ° H= 1 -1 1 U 0 cfm Heating Coil Supply Fan 0 104 F 2,000 cfm ROOM 69 OF 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62°F 55/54°F 55/54°F Outside Air 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm 47.1 -� % ` ROOM 76/62°F 75/62°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Hicks Residence Date 8/17/2018 System Name HVAC-Garage Floor Area 1,315 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 573� 12,199 1,724 407 Return Vented Lighting 0 Return Air Ducts 0 Return Fan 0 Ventilation 0 0 0 0 Supply Fan 0 Supply Air Ducts 0 TOTAL SYSTEM LOAD 12,199 1,724 PEAK Heating System Sensible Output per System 40,000 15,146 Total Output Btuh 40,000 Output Btuh/s ft 30.4 0 Cooling System 0 Output per System 36,000 0 Total Output Btuh 36,000 0 Total Output Tons 3.0 0 Total Output Btuh/s ft 27.4 Total Output s ft/Ton 438.3 15,146 Air System CFM per System 1,100 HVAC EQUIPMENT SELECTION Airflow cfm 1,100 Samsung AC036NMTDFCA 26,837 3,640 24,983 Airflow cfmis ft 0.84 Airflow cfmrron 366.7 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 26,837 3,640 24,983 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above siven at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4 1­ 0 cfm 70 OF 70 OF 105 OF 105 IF �--� H. f I M Heating Coil Supply Fan 1.100 cfm 0 I l �_ I -- t 105 OF 'ROOM in 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 0 cfm 75 / 62 IF 75/62OF 55/54OF 55/54OF � Cooling Coil Supply Fan 1,100 cfm 1 55 / 54 OF — 48.1 % ROOM 75 / 62 IF ZONE LOAD SUMMARY Project Name Hicks Residence Date 811712018 System Name HVAC-Master Floor Area 1,467 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM I Sensible Latent CFM Sensible Master Bdrm Zone 1.0 0 Aug 3 PM 780 16,234 1.923 414 15,251 TOTALS 0 0 0 0 Aug 3 PM 16,234 1,923 15,251 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Hicks Residence Date 811712018 System Name HVAC-Living Floor Area 4,443 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible GreaUKiftou./Off Zone 1.0 0 Aug 3 PM 3,406 70,193 5,825 1,877 68,866 TOTALS1 0 0 0 01 Aug 3 PM 70,193 5, 825 66,866 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name ©ate 8/17/2018 Hicks Residence System Name Floor Area HVAC-Casita 1,352 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent He-ating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Casita Zone 1.0 0 Aug 3 PM 873 17,942 1,268 496 18,184 Bdrm 1 Zone 1.0 0 Aug 3 PM 375 7,700 505 152 5,555 TOTALS 0 0 0 0 Aug 3 PM 25,642 1,772 23,739 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Hicks Residence Date 811712018 System Name HVAC-Garage Floor Area 1,315 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Garage Zone 1.0 0 Aug 3 PM 573 12,199 1,724 407 15,146 TOTALS 01 01 0 01 Aug 3 PM IZ 199 1,724 15,146 (BLOCK LOAD) ROOM LOAD SUMMARY Project Name Date Hicks Residence 811712018 System Name Floor Area HVAC-Master 1,467 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFM I Sensible Master Bdrm Zone I Master Bedroom 1 1 7801 16,2341 1,923 780 16,2341 1,9231 4141 15,251 PAGE TOTAL TOTAL* 760 16.234 1,923 414 15,251 7,901 16,234 1,923 414 15,251 * Total includes ventilation load for xonaf ROOM LOAD SUMMARY Project Name Date Hicks Residence 811712018 System Name Floor Area HVAC-Living4,443 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult.P3,4061 FM Sensible Latent CFM Sensible Latent CFM Sensible Great/Kiftou./Off Zone GreaUKitchen/Lounge 170,193 5,825 3,4061 70,1931 5,825 1,8771 68,866 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal 3.4061 70,193 5,825 1,877 68,866 3.406 70,193 5,825 1,877 68,866 ROOM LOAD SUMMARY Project Name Date Hicks Residence 8/17/2018 System Name Floor Area HVAC-Casita 1,352 ROOM LOAD SUMMARY ROOM COOLING PEAK I COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Casita Zone Casita 1 873 17,942 1,268 873 17,942 1,268 496 18,184 Bdrm 1 Zone Bedroom 1 1 375 7,700 505 3751 7,700 5051 1521 5,555 PAGE TOTAL TOTAL' 1,2481 25,6421 1,772 647 23.739 1,248 25,642 1,772 647 23,739 " Total includes ventilation load for zonal ROOM LOAD SUMMARY Project Name Date Hicks Residence 811712018 System Namfl Floor Area AC -Gary e 1,315 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. I CFM Sensible Latent CFM I Sensible Latent CFM I Sensible Garage Zone I Garage 1 1 573 12,199 1,724 573 12,199 1,724 407 15,146 PAGE TOTAL TOTAL* 573 12.199 1,724 407 15,146 5731 12,199 1,724 407 15,f46 * Total includes ventilation load for zonal ROOM HEATING PEAK LOADS Project Name Date Hicks Residence 1 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Time of Peak Jan 1 AM 1,467.00 ft2 Outdoor DrY P Bulb Tem erature 26 °F Floor Area Indoor Dry Bulb Temperature 70 °F Conduction R-38 Roof WIR-13 R-38 Flat Roof W/ R-10 R-21 Wall Western .49/.23 Western .6/.16 Western .35/.24 Slab -On -Grade "R-0 Interior Surface Area U-Value X 0.0194 X X 0.0225 X X 0.0690 X X 0.4900 X X 0.6000 X X 0.3500 X X 0.7300 X X 0.3560 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an astersk (') denote conduction through an interior surface to another room 4T OF Page Total Btu/hr 1,032 257 2,295 3,018 940 1,269 2,987 0 1 11,7991 Infiltration:[ 1.00 X 1.064 X 1,467 X 11.80 X 0.256 / 60 ] X d4 = Schedule Air Sensible Area Coiling Height ACM AT Fraction 1 3,4531 TOTAL HOURLY HEAT LOSS FOR ROOM 15,251 ROOM HEATING PEAK LOADS Project Name Hicks Residence Date 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Lounge Floor Area 4,443.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr 44 = 2,839 44 c 340 44 c 275 44 = 9,619 44 = 13,380 44 = 6,906 44 c 1,940 44 = 1,661 44 = 444 44 = 1,225 44 c 528 44 = 8,507 44 = 4,605 44 = 3,762 44 c 2,377 0 = 0 = = = = = = Page Total 58,409 / 60 ] X 44 i0,457 AT R-38 Roof W/R-13 3,320.0 0.0194 R-38 Flat Roof WI R-10 344.0 0.0225 Skylight 16.0 0.3900 R-21 Wall 3,168.2 0.0690 Westem .491.23 620.6 0.4900 Westem .351.24 448.6 0.3500 Monument .491.23 90.0 0.4900 French Door .741..14 51.0 0.7400 Western .351..2 28.8 0.3500 Western .61..16 46.4 0.6000 Woad Door 24.0 0.5000 Western .381,18 508.8 0.3800 Western.571.16 183.6 0.5700 Westem .571.2 150.0 0.5700 Slab -On -Grade perim = 74.0 0.7300 'R•0 Interior Surface 272.0 0.3560 Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 4,443 X Area another room 11.80 X 0.256 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 68,866 ROOM HEATING PEAK LOADS Project Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 967.00 ft2 Indoor Dry Bulb Temperature 70 OF11 Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area U-Value AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof WIR-13 862.0 X 0.0194 X 44 737 R-38 Flat Roof WI R-10 105.0 X 0.0225 X 44 104 R-21 Wall 1,023.9 X 0.0690 X 44 3,109 Western .35/.2 35.0 X 0.3500 X 44 539 Western .5/.23 282.8 X 0.5000 X 44 6,222 Western .35/.24 33.3 X 0.3500 X 44 513 Western .48/.19 15.0 X 0.4800 X 44 317 Slab -On -Grade perim = 136.0 X 0.7300 X 44 4,368 *R-0 Interior Surface 280.0 X 0.3560 X 0 0 X X X X X X X X X x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X Schedule Air 5ensibfe Fraction through an :nterior surface X 967 X Area to another room 11.80 X 0.256 Ceiling Heigh[ ACH Page Total / 60 ] X AT 15,908 = 2,276 TOTAL HOURLY HEAT LOSS FOR ROOM 18,184 ROOM HEATING PEAK LOADS Project Name Hicks Residence ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction DESIGN CONDITIONS Bedroom 1 Time of Peak 385.00 ft2 Outdoor Dry Bulb Temperature 70 OF Area R-38 Roof WIR-13 385.0 X R-21 Wall 78.8 X Western .35/.24 79.2 X Western .5/.23 95•0 X Slab -On -Grade perim = 24.0 X 'R-0 Interior Surface 662.0 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room U-Value AT OF Page Total Date 811712018 Jan 1 AM 26 OF Btu/hr 329 239 1,220 2,090 771 0 1 4,6491 Infiltration:[ 1.00 X 1.064 X 385 X 11.80 X 0.256 / gp J X 44 Schedule Air Sensible Area Ceiling Height ACH AT Fraction 1 9061 TOTAL HOURLY HEAT LOSS FOR ROOM 5,555 ROOM HEATING PEAK LOADS Project Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Floor Area 1,315.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x to Ceiling U-Value X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof WIR-13 1,315.0 0.0194 44 1,124 R-21 Wall 870.0 0.0690 44 2,641 Western .351..24 84.0 0.3500 44 1,294 Insulafed Garage Door 352.0 0.0788 44 1,221 SaHd Wood Door 24.0 1.45001 44 1,531 Slab -On -Grade perim = 132.0 0.7300 44 4,240 R-0 Interior Surface 272.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,315 X Area another room 10.00 X 0.302 Height ACH Page Total / 60 ] X ❑T 12,051 = 3,095 TOTAL HOURLY HEAT LOSS FOR ROOM 15,146 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name I Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,467.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 °F Outdoor Daily Ran e. 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof W/R-13 (W) 1,207.0 X 0.0194 X = 657 R-38 Flat Roof WIR-10 (W) 260.0 X 0.0225 f928.0 X = 450 R-21 Wall (N) 30.0 X 0.0690 X = 64 R-21 Wall (S) 181.6 X 0.0690 X = 476 R-21 Wall (W) 544.4 X 0.0690 X 55.0 = 2,066 "R-0 Interior Surface 462.0 X 0.3560 X 0.0 = C, X X = X X = X X = Page Total 3,713 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr D11 (S) 140.0 X 21.2 + 0.0 X 26.2 = 2,965 W15 (S) 0.0 X 19.9 + 35.6 X 23.4 = 835 W14 (S) 10.8 X 18.9 + 0.0 X 24.2 = 204 W16 (W) 10.8 X 18.9 + 24.2 X 54.5 = 1,521 W13 (W) 12.7 X 18.9 + 0.0 X 54.5 = 240 W12 (W) 7.6 X 16.9 + 0.0 X 54.5 = 143 W11 (W) 7.6 X 18.9 + 0.0 X 54.5 = 143 W10 (W) 8.7 X 18.9 + 0.0 X 54.5 = 164 X + X = Page Total 6,215 Internal Gain Btu/hr Occupants 4 4 Occupants X 245 Btuh/occ. = 1,079 Equipment 1,467 Floor Area X 0.50 w/sgft = 2,503 Infiltration: 1.064 X 0.$9 X 77.48 X 37 = 2,723 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,234 Latent Gain Btu/hr Occupants 4 4 Occupants X 155 Btuh/occ. = 683 Infiltration: 4,771 X 0.89 X 77.48 X 0.00376 = 1,240 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 683 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Hicks Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Lounge Outdoor Dry Bulb Temperature Floor Area 4,443.00 ftZ Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: Onanue Surfaces R-38 Roof WAR-13 R-38 Flat Roof WI R-10 R-21 Wall R-21 Wall Wood Door R-21 Wall R-21 Wall "R-0 Interior Surface Orientation (N) (N) (N) (E) Date 811712018 Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' a = = = s c = = - 3,320.0 0.0194 56.0 344.0 0.0225 56.0 951.8 0.0690 23.0 1,075.9 0.0690 33.0 24.0 0,5000 33.0 707.7 0.0690 26.0 432.8 0.0690 33.0 272.0 0.3560 0.0 Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room- 1 . Cooling Load Temperature Difference (CLTD) Fenestration Skylight 009 W27 ❑02 W25 W24 W23 W26 W28 Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.9 16.0 58.2 0.0 18.3 55.0 18.3 0.0 15.9 99.0 15.9 0.0 18.3 88.0 18.3 0.0 15.9 74.8 15.9 0.0 15.9 19.0 15.9 0.0 15.9 19.0 15.9 0.0 15.9 20.4 15.9 0.0 15.9 1 27.0 1 15.9 Page Total 112 OF 78 OF 34 OF Btu/hr 3,613 433 1,511 2,450 396 1,270 985 0 10,657 Btu/hr 931 1,008 1,575 1,613 1,190 302 302 324 429 7.676 Internal Gain Btu/hr Occupants 13.3 Occupants X 245 Btuh/occ. 3,. Equipment 4,443 Floor Area X 0.50 W/sgft = 7,; Infiltration: 1.064 X 0.89 X 234.65 X F 37 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,1931 Latent Gain Btu/hr Occupants 13.3 Occupants X 155 Btuh/occ. = 2,068 Infiltration: 4,771 X 0.89 X 234.65 X 0.00376 = 3,757 Air Latent CFM E[. A OW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,0681 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Lounge Outdoor Dry Bulb Temperature 112 OF Floor Area 4,443.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr D05 (N) 0.0 X 18.3 + 45.0 X 18.3 = 625 W33 (N) 0.0 X 15.9 + 9.0 X 15.9 = 143 W29 (E) 0.0 X 15.9 + 19.8 X 30.2 = 597 W29 (E) 0.0 X 15.9 + 19.8 X 30.2 = 597 W29 (E) 0.0 X 15.9 + 19.8 X 30.2 = 597 D 18 (E) 0.0 X 20.0 + 27.0 X 28.3 = 764 W18 (E) 19.1 X 14.4 + 9.7 X 26.3 = 531 D17 (E) 0.0 X 20.0 + 24.0 X 28.3 = fi79 W17 (E) 0.0 X 17.9 + 20.3 X 27.4 = 557 Page Total 5.291 Internal Gain Btulhr Occupants 13.3 Occupants X 245 Btuh/occ. = 3,269 Equipment 4,443 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.89 X 234.65 X 371 = 8,246 Air Sensible CFM ELA .NT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,193 Latent Gain Btulhr Occupants 13.3 Occupants X 155 Btuh/occ. = 2,068 Infiltration: 4,771 X 0.89 X 234.65 X 0,00376 = 3,757 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,068 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Hicks Residence 1 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Lounge Outdoor Dry Bulb Temperature 112 OF Floor Area 4,443.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 of Outdoor Daily Range: 34 OF Surfaces Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration D13 W20 016 D14 D12 W21 004 W22 D03 Orientation Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 75.6 18.3 0.0 32.0 53.1 15.9 26.9 30.2 189.6 14.3 0.0 14.3 402.0 18.3 0.0 18.4 183.6 17.3 0.0 17.4 0.0 17.9 26.1 18.0 0.0 18.3 45.0 18.4 0.0 15.9 19.0 30.2 142.5 18.8 7.5 30.7 Page Total Btu/hr Btulhr 1,386 1,656 2,707 7,371 3,183 469 827 l�7L�1 21 Internal Gain Btu/hr Occupants 13.3 Occupants X 245 Btuh/occ. 3, Equipment 4,443 Floor Area X 0.50w/sgft - 7• Infiltration: 1.064 X 0.89 X 234.65 X 37 = C Air Sensible GRA ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,193 Latent Gain 1 Btu/hr Occupants .13.3 Occupants X 155 Btuh/occ. = 2,068 Infiltration: 4,771 X 0.89 X 234.65 X 0.00376 = 3.757 Air Latent CRO ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Z,068J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Lounge Outdoor Dry Bulb Temperature 112 OF Floor Area 4,443.00 ft2 Outdoor Wet Bulb Temperature 78 of Indoor Dry Bulb Temperature 75 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 015 (W) 83.8 X 14.3 + 75.8 X 25.0 = 3,089 W31 (W) 0.0 X 15.9 + 11.0 X 30.2 = 332 W32 (W) 0.0 X 15.9 + 11.0 X 30.2 = 332 ❑16 (W) 126.3 X 14.3 + 33.3 X 25.0 = 2.634 X + X = X + X = X + X = X + X = X + I X = Page Total 5,38 Internal Gain Btu/hr Occupants 13.3 Occupants X 245 Btuh/occ. = 3,269 Equipment 4,443 Floor Area X 0.50 w/sgft = 7,582 Infiltration: 1.064 i. X 0.89 X 234.65 X 37 = 8,246 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,193 Latent Gain Btu/hr Occupants 13.3 Occupants X 1 1551 Btuh/occ. Infiltration: 4,771 X 0.89 X 234.65 X 0.00376 = 3.757 Air Latent CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,068 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 967.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 °F Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btulhr R-38 Roof WIR-13 (N) 862.0 X 0.0194 X 56.0 = 938 R-38 Flat Roof WI R-10 (N) 105.0 X 0.0225 X 56.0 = 132 R-21 Wall (N) 515.0 X 0.0690 X 23.0 = 817 R-21 Wall (E) 114.8 X 0.0690 X 33.0 = 261 R-21 Well (SW) 136.7 X 0.0690 X 31.4 = 297 R-21 Wall (W) 257.4 X 0.0690 X 33.0 = 586 'R-0 Interior Surface 280.0 X 0.3560 X 0.0 = 0 X X = X X = Page Total 3.032 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr W06 (N) 0.0 X 14.4 + 17.5 X 14.4 = 252 W05 (N) 0.0 X 14.4 + 17.5 X 14.4 = 252 006 (E) 0.0 X 18.5 + 90.0 X 32.2 = Z897 D07 (E) 0.0 X 18.5 + 115.2 X 32.2 = 3,708 W30 (SW) 0.01 X 15.9 + 33.3 X 21.8 = 727 ❑10 (W) 0.0 X 18.5 + 77.6 X 32.2 = 2,496 W08 (W) 0.0 X 16.7 + 7.5 X 27.9 = 209 W09 (W) 0.0 X 16.7 + 7.5 X 27.9 = 209 X + X Page Total 10,754 Internal Gain Btulhr Jccu an:s 2.9 Occupants X 245 Btuh/occ. = 711 E ulpment 967 Floor Area X 0.50 W/sgft = 1,650 Infiltration: 1.064 X 0,89 X 51.07 X 37 = 1,795 Air Sensible CEM EI_A AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,942 Latent Gain Btuihr Occu ants 2 9 Occupants X 155 Btuh/occ. = 45D Infiltration: 4,771 X 0.89 X 51,07 X 0.00376 = 618 Air Latent CFM ELA A1N TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 450 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 385.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 RoorWIR-13 (N) 385.0 X 0.0194 X 56.0 = 419 R-21 Warr (E) 78.8 X 0.0690 X 33.0 = 179 'R-0 Interior Surface 662.0 X 0.3560 X 0.0 = 0 X X _ X X = X X = X X = X X = X X = Page Total 598 Items shown with an asterisk () denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr W29 (E) 0.01 X 15.9 + 1. 19.8 X 30.2 = 597 W29 (E) 0.0 X 15.9 +1 19.8 X 30.2 = 597 W29 (E) 0.0 X 15.9 + 19.8 X 30.2 = 597 W29 (E) 0.0 X 15.9 + 19.8 X 30.2 = 597 ❑08 (E) 0.0 X 16.5 + 95.0 X 32.2 = 3,058 X + X = X + X = X + X = X + X = Page Total 5,44 Internal Gain Btu/hr Occupants 1•2 Occupants X 245 Btuh/occ. - 263 Equipment 385 Floor Area X 0.50 w/sgft 657 Infiltration: 1.064 X 0.89 X 20.33 X 37 = 715 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,700 Latent Gain Btu/hr Occupants 12 Occupants X 155 Btuh/occ. - 179 Infiltration: 4,771 X 0.89 X 20.33 X 0.00376 326 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 175 RESIDENTIAL ROOM COOLING LOAD SUMMARY Pre;ect !Name Date Hicks Residence 811712018 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Outdoor Dry Bulb Temperature 112 OF Floor Area 1,315.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Tempera ure 75 OF Outdoor Dailv Ranae: 34 OF Ooaoue Surfaces R-38 Roof WIR-13 R-21 Well R-21 Wall Insulated Garage Door R-21 Wall R-21 Wad Solid Wood Door 'R-0 Intefior Surface Orientation (W) (N) (E) (E) (S) Items shown with an asterisk (") denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Fenestration W01 W02 W03 W004 Orientation (N) (N) (N) (N) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 1,315.0 0.0194 56.0 274.0 0.0690 23.0 241.0 0.0690 33.0 352.0 0,0788 33.0 158.0 0.0690 26.0 197.0 0,0690 33.0 24.0 1.4500 33.0 272.0 0.3560 0.0 L Page Total Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X� GLF = = z = _ _ - - 0.0 15.9 21.0 15.9 0.0 15.9 21.0 15.9 0.0 15.9 21.0 15.9 0.0 15.9 21.0 15.9 Page Total Btu/h r 1,431 i,1 5,2 Btu/h r 334 334 334 334 1 Internal Gain Btu/hr Occupants 3 9 Occupants X 245 Btuh/occ. = 967 F_, ui ment 1,315 Floor Area X 0.50 E= w/sq ft = 2,244 Infiltration: 1.064 X 0.89 X 69.45 X 37 2,441 Air Sensible CRM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,199 Latent Gain Btu/hr Occupants 3.9 Occupants X 155 Btuh/occ. = 612 Infiltration: 4,771 X 0.89 X 69.45 X 0.00376 = 1,112 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 612