Loading...
09-0175 (AR) Revision 1f Binx#� Qty of La QWnta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # U(' Project Address: Owner's Name: A. P. Number:3 .— D —01y Address: Legal Description: City, ST, Zip: 2 �3 Contractor: iC — Telephone Address: K-38 o Project Description: City, ST, Zip: O Telephone: L ' f;•;:•r;:;:.;.y: r State Lic. # : City Lic. #; Arch., Engr., Designer:. ✓ Address: T, f'/QM I +" . 4P 69.— . City, ST, Zip: Telephone: —zff State Lic.......;: _2/p :::>;> < .; > s'::z ::`:'. Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Pers n: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Pian Sets Req'd Recd TRACKING PERMIT FEES . Plan Check submitted item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan ue 2'd Review, ready for corrections Iss is Electrical Subcontactor List Called Contact Person $ Plumbing Grant Deed Plans picked up. S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Jrd Review,.ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 2 X130 ��rv� TITLE 24 REPORT Title 24 Report for: BOWER RESIDENCE'S CASITA 78955 DULCE DEL MAR LA QUINTA, CA 92253 Project Designer: SILFER AND ASSOCIATES 45-175 PANORAMA DR., STE. A-1 Palm Desert, Ca 92260 (760) 674-8100 CITY OF LA QUINTA BUILDING $ SAFETY DEPT. APPROVED FOR CONSTRUCTION DATES 0 BY • JeP•t�%Sias-, �/ Report Prepared By: Armando Chavez GLS Architecture Group 74991 Joni Dr. #9 Palm Desert, CA 92211 (760) 340-3528 Job Number: Date: 4/23/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number. User Number: 5553 I/ Or ITf`cA. Ii . " TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 7 9 EnergyPro 4.4 by EnergySoft Job Number: User Number: 5553 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R ROWER_RE.S.I.DER- GES CAS -1 Area: 29 ft2 Avg. U: 0.34 4/23/_2QQ9 _._.. Project Title 0.33 Number of Stories: Date _7_8.95.5_DULGE_DELMAR-LA QULNTA_ # of Thermostat Zone Name Floor Area F Project Address HVAC_SYSTEM- 37.3 --3,Z30 Building Permit # -- _G.LS_Ar_ch.itectur_e G.ro_up__ __-_ .Door None` 7( 60) 340-3528 -- - Documentation Author Telephone Plan Ch/Date Check/Da _Ene.r_�q Pro 45_-90 CA_Climate Zone 1.5 Field Check/Date Compli ce Method _0.074 -2-1.9. _lR=0 0_ Climate Zone ,J TDV Standard Proposed Compliance ^225_-9.0 (!@tu/sf-yr) Design Design Margin Space Heating 1.20 0.52 0.68 ❑❑ Space Cooling 79.94 71.73 8.22 Fans 11.49 11.37 0.12 Domestic Hot Water 67.35 69.75 -2.40 Pumps _ 0.00 0.00 0.00 Totals 159.98 153.37 6.61 Building Type: RX Single Family ❑ Multi Family Building Front Orientation: Fuel Type: ❑ Addition ❑ Existing + Add/Alt (NE) 45 deg Propane Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Fenestration: Insulation Average Ceiling Height: Area: 29 ft2 Avg. U: 0.34 Number of Dwelling Units: Ratio: 7.9% Avg. SHGC: 0.33 Number of Stories: BUILDING ZONE INFORMATION ❑New # of Thermostat Zone Name Floor Area Volume Units Zone Type Type HVAC_SYSTEM- 37.3 --3,Z30 X00_ Conditioned--Setback- OPAQUE SURFACES Insulation Act. X Type Frame Area U -Fac. Cay. Cont. Azm. Tilt .Roof Wood_3.7.3_ ❑New _0.025- _508_ _R_0"_ _0__0 ❑ .Wall-- Wood- 66_ _0..07_4_ -R49_ _RR0..0_ _31.5_90 F-1 .Door None` 24 _0.5.00_ _None_ X0_0_ ^31.5__90 Wall_ Wood_ 1.9.4_ _0.07.4_ _R-1.9_ _ER0_0_ 45_-90 Wall_ -Wood- 207_ _0.074 -2-1.9. _lR=0 0_ 135_-90 ❑❑❑ Wall__- Wood- 1.38_ _0..074_ __R-1.9_ X0_0_ ^225_-9.0 373 ft2 nla ft2 0 ft2 373 ft2 10.0 ft 1.00 1 Vent Hgt. Area -2 -n/.a Gains Condition Y / N Status JA IV Reference Location / Comments - ❑New _01A1.8 akV_C_SYSTEM X ❑New 0.9_A5 RUC -SYSTEM IXC ❑New 28_A4 HAV_C_SYSTEM _ IX ❑New 09 95 HAVC_SYSTEM ❑ Nem 09--A5 HAVC_SYSTEM _ . ❑❑New _0.9495 HAV_C_SYSTEM __ F-1 ❑❑ ❑❑❑ - ❑❑ _. ❑❑ ❑ ❑ -: ❑❑❑❑ - Run Initiation Time: 04/23/09 16:33:47 Run Code: 1240529627 EnergyPro 4.4 by Energysoft User Number: 5553 Job Number: Page:3 of 9 Certificate Of Compliance : Residential (Part 2 of 4) CF-1 R BOWER RESIDENCE'S CASITA Project Title Insulation Location JA IV Reference 4/23/2009 Date FENESTRATION SURFACES # Type Area U-Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 1._. Window F_ront_(NE) 15..0_ _0.3.40-NERC _0 33 -NE 45_ _9.0- New_ Andersen_P_ermashield 2 Window Front (NNE. 3.3 0.340 NFRC 0_33 NFRC 45 90 New Andersen Permashield _ -HA-VC-SYS-TEM_ HAVC SYSTEM 3 Window Left (SE) 3.0 0.340 NFRC 0_33 NFRC 135 90 New Andersen Permashield HAVC SYSTEM 4 Window Left (U. 3.0 0.340 NFRC 0_33 NFRC 135 90 New Andersen Permashield HAVC SYSTEM _. 5 Window Left (SE) _ 3.0 0.340 NFRC 0_33 NFRC 135 90 New Andersen Permashield HAVC SYSTEM_­ 6 Window Rear (SW) 2.0 0.340 NFRC 0_33 NERC 225 90 New Andersen Permashield HAVC SYSTEM 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin _ Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 _ 4 Bug Screen 0.76 5 Bug Screen 0.76 _ 6 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (sf) (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Type Length R -Val. Insulation Location JA IV Reference Condition Status Location/ Comments EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:4 of 9 1 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R BOWER RESIDENCE'S CASITA Project Title 4/23/2009 Date HVAC SYSTEMS Heating Location _ Type Minimum Eff Cooling Type Minimum Condition Eff Status Thermostat Type HVAC SYSTEM Central Furnace _ 93% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct Condition R -Value Status Ducts Tested? HVAC SYSTEM Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. _ POWERSTAR AE125 Small Elec. No Pipe Insulation 1 0 2 New 0.95 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: SILFER AND ASSOCIAT S Address: 45-175 PANORAMA DK. ISTE. A-1 Telephone: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) Documentation Author Name: Armando Chavez _ Title/Firm: GLS Architecture Group a Address: 74991 _J.oni_Dr. #.9 _J Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R BOWER RESIDENCE'S CASITA 4/23/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justltication ano documentation submitted. I The Roof "R-38 Roof Attic" includes a Radiant Barrier. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC SYSTEM" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC SYSTEM" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 58MTB60-12 CNP 38HD 1.5 T' includes credit for a 11.0 EER Condenser. I EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:6 of 9 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE- MENT _ _ _ Building Envelope Measures ❑ ❑ ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ EK ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ NO ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ N ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ NO ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 permfinch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ IR ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExFltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ a ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ 191 ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ 0 ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - DESCRIPTION N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) I § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. ❑X ❑ a ❑ ® ❑ ❑X ❑ ❑ ❑X ❑ ❑ -1 X, ❑ ❑ ❑ ❑ a ❑ ❑ ❑ ❑ ❑ a ❑ a] ❑ ❑X 0 a a FAI Fol ❑ ❑ ❑ § I50(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:8 of 9 IFiVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE BOWER RESIDENCE'S CASITA 4/23/2009 SYSTEM NAME FLOOR AREA HVAC SYSTEM 373 (Number of Systems 1 11 Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 150.1 Cooling System Output per System 16,900 Total Output (Btuh) 16,900 Total Output (Tons) 1.4 Total Output (Btuh/sgft) 45.3 Total Output (sgtVTon) 264.9 CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above qiven at ARI conditions 26.0 of i OutsideAir 0 cfm 69.5 of 69.5 of --(F Supply Fan 595 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFMISensiblel Latent 11CFMJ Sensible 248 5,715 657 47 4,3991 0 472 _1 3151 o 0 0 0 0F 00 0 0 472 315 6 659 657 5,028 owu — I 595 Carrier 58MTB60-12 CNP 38HD 1.5 T 14,650 10 56,0001 1.60 -- 22.5 0.0 Total Adjusted System Output 14,650 10 56,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am' 157.9 of Heating Coil !% Return Air Ducts `S Supply Air Ducts 157.4 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS (Airstream TemiDeratures at Time of Coolina Peakl 11.0 / 77.6 of Outside Air 0 cfm 78.7/63.2 of 78.7/63.2OF 78.7/63.2OF M 55.6/54.3OF --(P Supply Fan 595 cfm Cooling Coil K Return Air Ducts `{ Supply Air Ducts 56.4/54.6OF 43.3% R.H. ROOMS 78.0 / 62.9 of EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:9 of 9