Loading...
12877 (SFD) Title 24r_1 L-A rl L -A 0 *12,100 to 73,000 Btuh (3.5 to 21.4 M) Cooling Capacity May 1993 -ARI Standard 210/240 Certified Ratings with Matching Outdoor Unit Supersedes December 1992 Typical Applications Closet installation With Pulse2lQD Furnace and Electronic Air Cleaner Utility Room Installation With G20E Whisperheat - Furnace and Humidifier Applications —Lennox designed and built up-flo evaporator coils can easily be installed with most Lennox up-flo fur- naces. Coils match most plenum openings of Lennox fur- naces. See Coil to Furnace Selector in this bulletin for more information. See condensing units bulletins (section Cooling Units — Condensing Units) for evaporator unit applications and cooling capacities. See heat pump outdoor unit bulletins (section Heat Pumps — Matched Remote Systems) for indoor coil applications and cooling and heating capacities. See FM21 bulletin in Heat Pumps— Matched Remote Systems for more information. Construction — Lennox designed and fabricated coils are constructed of precisely spaced ripple -edged enhanced alu- minum fins machine fitted to rifled Cooper tubes. Lanced fins allow'for maximum exposure of fin surface to air stream. Copper rifled -tubing construction provides long coil life and ease of service. Rifled tubing provides superior refrigerant flow resulting in maximum heat transfer. Twin coils as- sembled in an "A" configuration provides extra large surface and contact area for maximum efficiency. Fins have collars that grip tubing for maximuT contact area resulting in excel- lent heat transfer. Flared shoulder tubing joints and s ' ilver sol- dering provide tight leakproof joints. Coils are thoroughly tested under pressure to insure leakproof construction. Drainpan is cons * tructed of a non -corrosive polymer and has dual 3/4 inch .(19 mm) f pt drain connections. Two-piece end panel allows easy access for coil servicing and cleaning. Re- frigerant lines are equipped with sweat connections on both suction (vapor) and liquid line. Fully Tested— Evaporator units have bee n thoroughly tested with matching condensing and heat pump units in the Len- nox Research Laboratory environmental test room. Air resis- tance data is from tests conducted in the Lennox air test chamber. Coil assemblies are shipped factory assembled and ready for installation. Check and Expansion Valve Kit Furnished— Check and expani- Sion valve is factory installed on all models. Adjustable CoflAdaptorBase Furnished— Adjustable adaptor base is furnished with coils to provide quick and easy installa- tion in a wide variety of applications. See Coil to Furnace Selec- tor, dimension drawings and application drawings, CF30-00 Non -Adjustable Adaptor Base (Optional) — Fixed width base (46J43) is available for C22 installations with G20E-Q5/6-150 model furnaces. See Specifications table, Coil to Furnace Selector, dimension drawings and application drawings. Full Height Empty Coil Cabinet Cabinet (Optional) — Cabi- nets are fully insulated with thick fiberglass insulation and are constructed of heavy gauge steel with a deluxe baked -on enamel paint finish, Bend -up flanges are provided in outlet opening of cabinet for ease of plenum connection in conven- tional. See Specifications tables, Empty Coil Cabinet to Fur- nace Selector and dimension drawing. Up -Flo tod. Twinning Kit (Optional) -7 Twinning kit LB-65597A.(3OJ76) is available to operate two C22-41, C22-46 or C22-65 coils simultaneously with one HS17 condensing unit and two furnaces. Kit contains necessary plumbing fit- tings to interconnect coils. Must be ordered extra. 0 The maple leaf symbol in this bulletin denotes Canadian only usage where applicable NOTE — Specifications, Ratings and Dimensions subject to change without notice. @1993 Lennox Industries Inc.