Loading...
11-0662 (AR) Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: White Casita 79-695 Liga La Quinta, CA Project Designer: Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR C NS/TRUCTION DAT r �4�Y Job .Number: ,j1lEC�i�� Date: AUG U 9 2011 7/19/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPrq5.1 by Ener Soft User Number. 2655 RunCode:2011-07-19711:42:36 ID: 0 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory: Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 �EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name White Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/19/2011 Project Address 79-695 Liga La Quinta California Energy Climate Zantal CA Climate Zone 15e Cond. Floor Area To694 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Wall Wood Framed R-19 732 New Roof Wood Framed Attic R-38 694 Radiant Barrier New Slab Unheated Slab -on -Grade None 694 Perim = 53' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 22.5 0.400 0.36 2.0 none Bug Screen New Front (N) 22.5 0.400 0.36 2.0 none Bug Screen New Left (E) 8.0 0.400 0.36 2.0 none Bug Screen New Left (E) 8.0 0.710 0.73 2.0 none Bug Screen New Rear (S) 48.0 0.400 0.36 2.0 none Bug Screen New Rear (S) 48.0 0.400 0.36 2.0 none Bug Screen New Rear (S) 21.4 0.400 0.36 2.0 none Bug Screen New Right (W) 24.0 0.400 0.36 2.0 none Bug Screen New Right (W) 24.0 0.400 0.36 2.0 none Bug Screen New Right (W) 24.0 0.400 0.36 2.0 none Bug Screen New Right (W) 21.4 0.400 0.36 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.63 All Pipes Ins New Ener Pro 5.1 by Ener Soft User Number.' 2655 RunCode: 2011-0 7-1 9 711:42:36 ID: Page 3 of 11 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name White Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/19/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 694.0 ftz Exposed Slab Floor, 3.500" thick at Casita The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 58MTS80-16 CNP 38HD 3 T includes credit for a 11.8 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Casita includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System Casita incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Casita includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System Casita incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Sok User Number 2655 RunCode: 2011-0 7-1 9 711:42:36 ID: Pa e 4 of 11 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date White Casita ❑ Multi Family ❑ Existing+ Addition/Alteration 7/19/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.08 1.56 1.52 Space Cooling 69.50 72.43 -2.93 Fans 13.96 17.02 -3.06 Domestic Hot Water 33.93 29.29 4.64 Pumps 0.00 0.00 0.00 Totals 120.47 .120.30 0.17 Percent Better Than Standard: 0.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 300 45 Fuel Available at Site: Natural Gas (E) 240 16 Raised Floor Area: 0 (S) 224 117 Slab on Grade Area: 694 (w) 240 93 Average Ceiling Height: 10.0 Roof 694 0 Fenestration Average U -Factor: 0.41 TOTAL: 272 Average SHGC: 0.37 Fenestration/CFA Ratio: 39.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 7/19/1011 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker LA tjbj" City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Si ned I Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rateWV Designer or Owner (per Business & Professions Code) Company L, VMSL&Z-5rW10 4 NA,• �%%% Address T•O• '1b-Dk 44 Nam�'q.,is �t r City/State/Zi , . Phone - r 8•�� ense # Date L �Sm GI► 9 7 • �4 gu-4fi Ener Pro 5.1 bV Ener Soft User Number: 2655 RunCode: 2011.07-19711:42:36 ID: Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name White Casita U -Factor Building Type IZI Single Family 1 ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 7/19/2011 OPAQUE SURFACE DETAILS 2 Window 22.5 Surface Type Area U- Insulation Joint Appendix Factor CavitylExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 255 0.074 R-19 0 90 New 4.3.1-A5 Casita Window Wall 224 0.074 R-19 90 90 New 4.3.1-A5 Casita 48.0 Wall 107 0.074 R-19 180 90 New 4.3.1-A5 Casita 0.400 NFRC Wall 147 0.074 R-19 270 90 New 14.3.1-A5 Casita 8 Roof 6941 0.025 R-38 0 0 =ew 14.2.1-A21 Casita Window Slab 6941 0.730 None I 1 01 180 1 New 4.4.7-A1 Icasita 24.0 FENESTRATION SURFACE DETAI ID Type Area U -Factor 1 Window 22.5 0.400 NFRC 2 Window 22.5 0.400 NFRC 3 Window 8.0 0.400 NFRC 4 Window 8.0 0.710 Default 5 Window 48.0 0.400 NFRC 6 Window 48.0 0.400 NFRC 7 Window 21.4 0.400 NFRC 8 Window 24.0 0.400 NFRC 9 Window 24.0 0.400 NFRC 10 Window 24.0 0.400 NFRC 11 Window 21.4 0.400 NFRC SHGC` 0.36 NFRC 0.36 NFRC 0.36 NFRC 0.73 Defau 0.36 NFRC 0.36 NFRC 0.36 NFRC 0.36 NFRC 0.36 NFRC 0.36 NFRC 0.36 NFRC Azm Ste 0 New 0 New 90 New 90 New 180 New 180 New 180 New 270 New 270 New 270 New 2701 New IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E Double Metal Double Metal Clear IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E IWC 6200 Alum/Low-E Location/Comments Casita Casita Casita Casita Casita Casita Casita Casita Casita Casita Casita I EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 6 of 11 (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Len Ove hang Left Fin Right Fin H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 8.0 2.8 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 10 18ug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 11 Isug Screen 0.76 8.0 2.8 2.0 0.1 2.01 2.0 I EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name White Casita Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/19/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Casita Casita 694 6,940 Totals 694 0 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Casita 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name aty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A. 0. SMITH FPS -50-224 1 Small Gas All Pipes Ins 43,000 50 0.63 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o �o ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ EnergyPro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-07-19T11:42:36 ID: Page 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name White Casita Date 7/19/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5 ' 3 c 5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(VA: 3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date White Casita 7/19/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655. RunCode: 2011-07-19711:42:36 ID: Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date White Casita 7/19/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 4150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number.' 2655 RunCode: 2011-07-19711:42:36 ID: Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name White Casita Date 7/19/2011 System Name Casita Floor Area 694 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 669 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 75,000 13,821 1,008 '241 11,435 Total Output Btuh 75,000 0 Output(Bt uh/s ft 108.1 798 562 Cooling System 0 0 Output per System 33,600 0 0 0 0 Total Output Btuh 33,600 0 1,008 0 Total Output Tons 2.8 798 562 Total Output Btuh/s ft 48.4 Total Output s ft/Ton 247.9 1 15,416 12,559 Air System CFM per System 1,260 HVAC EQUIPMENT SELECTION Airflow cfm 1,260 Carrier 58MTB80-16 CNP 38HD 3 T 26,782 1,615 75,000 Airflow cfm/s ft 1.82 Airflow cfm/Ton 450.0 Outside Air % 0.0% Total Adjusted System Output 26,782 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,615 Aug 3 PM 75,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 1,260 cfm 70 OF 70 OF 115 OF — Heating Coil 115 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 76 / 62 Outside Air 0 cfm 76 / 62 OF OF 76 / 62 OF 55 / 54 OF Supply Fan Cooling Coil 56 / 54 OF 1,260 cfm 47.0% ROOM 75 / 62 OF EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-07-19T11:42:36 /D: Page 11 of 11 Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 7/19/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name White Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/19/2011 Project Address 79-695 Liga La Quinta California Energy Climate ZonTotal CA Climate Zone 151 Cond. Floor Area 694 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF=4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Wall Wood Framed i1 R-19 732 �IVew Roof Wood Framec 694 Radiant Barrier Ne* j Slab Unheated Sla - -on G ff N We I N 694 Perim = 53'kz-f ew iii niNG & SAFETY DEPT. - Q I0 Y • CT R Y_- Y_—ILA— ILA—FENESTRATION IFENESTRATION1 Exterl r Orientation Area(ft`) Factor SHGC Overhang S,idefins Shades Status Front (N) 22.5 0.400 0.36 2.0 no'2e �4ug Screen New _ Front (N)_ 22.5 _ 0.400_,-�- � 0.36-2.0--, ���-none `--�_Bug,Screen7 ;.-; New Left (E) fir 8.0 r 0100 t 0.36 2.0 'V// none Bug Screen L New Left (E);8 00 ,i 10.710 0.73 Bug Screen ' fe New Rear (S) , 48.0) f 0.400 0!362 0 V f Ione �l Bug Screen t `' ' jNew ! , Rear (S) "48.6-' r 0.400 .r �r � Ot36� 2.0' ; none Bug; Screen l 1 f ; i _ ; New Rear (S) 21.4 0.400 h0,36 0 none Bug Screen New Right (W). 24.0 0.400 .,0.36 2.0 none Bug Screen New Right (W) 24.0 0.40P\\0.,�6 2.0 none Bug Screen New Right (W) 24.0 _,0,40.2 0.36 2.0 none Bug Screen New Right (W) 21.4 0.400 ).,36 2.0 none Bug Screen New HVAC SYSTEMS City. Heating ,� � Min. Ejf Cooling Min. Eff Thermostat Status 1 Central Fumace. 80% FUE Split Air Conditioner 13.0 SEER Setback New /� le HVAC DISTRIBUTION*' Duct Location Heatin Cooling Duct Location R -Value Status Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.63 All Pipes Ins ~ ---/Vw AUG 0 (? ^e Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-07-19711:42:36 Pae 1 of 5 4-0A Reg: 211-N0035813A-000000000-0000 Registration Date/Time: 2011/07/19 14:56:15 I�S-'-Provider: CalCERTS, Inc V Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 7/19/2011 PERFORMANCE CERTIFICATE: Residential Part 2 of 5CF-1 R Project Name White Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7 12011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 694.0 ftz Exposed Slab Floor, 3.500" thick at Casita The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. h —5 HERS REQUIREDyVERIFICATION`� `� Items in this section require field te'stin'g and/oar verlf�c�a� na y a certified HERS Rater:-The'inspector�must receive a completed CF -4R form for each of the meas�r.�s Ilsted`below for final to be given. The Cooling,System Carrier 58MTB80-16 CNP 38 3 T includescre'dlt'for a 11.8 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. ^ : The HVAC System Casita includes credit for Verifie YQafi Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System Casita incorporate (ERS Verified Ref r19prant Charge or a Charge Indicator Display. The HVAC System Casita inclupde credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. 40 K The HVAC System Casita incorporatbs HERS -verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct ,Qteda. leakage meets the spe fi-p v NIJ, Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 2 of 5 Reg: 211-N0035813A-000000000-0000 Registration Date/Time: 2011/07/19 14:56:15 HERS Provider: CalCERTS, Inc a Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 7/19/2011 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date White Casita 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 7/19/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.08 1.56 1.52 Space Cooling 69.50 72.43 -2.93 Fans 13.96 17.02 -3.06 Domestic Hot Water 33.93 29.29 4.64 Pumps 0.00 0.00 0.00 Totals 120.47 120.30 0.17 Percent Better Than Standard: 0.1% BUILDING COMPLIES - HERS VERIFICATION REQ~'TIRED ef►estration Building Front Orientation: (N) o deg iI Ext. Walls/Roof Wa" -tea Area Number of Dwelling Units: 1.00 (N) I" 0 45 Fuel Available at Site: Natural Gas (E) 40 16 Raised Floor Area: 0 (S) 224 117 Slab on Grade Area: 694 (w) 240 93 Average Ceiling Height: 10.0 Ro f 694 0 Fenestration Average U -Factor: 0.41 TOTAL: 272 Average SHGC: 0.37 Fenestrati/CFA Ratio: 3s.2 on REMARKS !A r STATEMENT OF COMPLIANC This certificate of compliance'lists the buildi features and specifications needed to comply with Title 24, Parts 1,e�A kinistralqeegulations and Part 6 the Efficiency Standards of the C fifornia Cade of a6gulations. The documentation aut or ere y certifies that the documentation is accurate and complete. Documentation Autho Company Insu-fo , c. Address 7710 Las Mo tanass Road, Suite 201 Name Joan D. Hacker 7719/1011 alm Desert Ca 271 760-345-1352 Cit /State/ i Phone Signed Date The indi id with overall design responsibility hereby certifies that the proposed building design represented in this set of construction ocut ants is consistent with the other compliance forms and worksheets, with the specifications, and with any other ca culations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Name City/State/Zip Phone Signed License If Date Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 3 of 5 Reg: 211-N0035813A-000000000-0000 Registration Date/Time: 2011/07/19 14:56:15 HERS Provider: CalCERTS, Inc .t Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 7/19/2011 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name White Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/19/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 255 0.074 R-19 0 90 New 4.3.1-A5 Casita Wall 224 0.074 R-19 90 90 New 4.3.1-A5 Casita Wall 107 0.074 R-19 180 90 New 4.3.1-A5 Casita Wall 147 0.074 R-19 1 270 90 New 4.3.1-A5 Casita Roof 694 0.025 R-38 0 0 New 4.2.1-A21 Casita Slab 694 0.730 None 0 180 New 4.4.7-A1 Casita a ------------------- FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status GlazingT e Location/Comments 1 Window 22.5 0.400 NFRC 0.36 NFRC 0 New Alumkow-�W Casita 2 Window 22.5 0.400 NFRC 0.36 NFRC 0 New Fl. C 6200 Alum/LowE Casita 3 Window 8.0 0.400 NFRC 0.36 NFRC 90 New ;Double Metal A Casita 4 Window 8.0 0.710 Default 0.73 Default 90 Ne Qouble Metal Tear Casita 5 Window y 48.0 0.400 NFRC -0.36 NFRC 180 Ne` _W IC�62Q0,,k) m1Low:E - Casita 6 Window' �. 48.0 0.400 NFRC ,r J 0.36 NFRC 180 dew IWC 62'00 Alum/Low-Er t 1, Casita 7 Window 121.4 0.400 NFRC 0.36 'NFRC 186 Ne IWC 6200 Alum/Low-E Casita 8 Window 24.0 %0.400 NFRC 0.36 NFRC 270 New IM 6200 Alum/Low-E Casita 9 Window 24.0 , 0.400 NFRC 0.36 NFRC 4 t `270 New 11WC 6200 Alum/Low-E Casita - - 10 Window d J24.0 r 0.400 NFRC 0.36 NFR,6 4,270 New `' IWC 6200 Alum/Low-E Casita , 1 11 Window of 11 '_21.4. 0.400 NFRC -6.36 NFRC 27,0 New IWC 6200 Alum/Low-E ! Casita Ar AK (1) U -Factor Type: 116-A = Default able fro �Stafhdards, NFRC = Labeled Value 2 SHGC Type: 116-B ,�pefault able from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS A ID Window Exterior Shade T e SH -HOM I Wd Overhang Left Fin Len I H t LExt I RExt Dist Len Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 2 Bug Screen `'t 76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen76 4.0 2.0 2.0 0.1 2.0 2.0 4 Bug ScreeIr A4 0.76 4.0 2.0 2.0 0.1 2.0 2.0 5 Bug Seen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 6 Bu dPleQn 0.76 8.0 6.0 2.0 0.1 2.0 2.0 7 Bug Scree 0.76 8.0 2.8 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 2.8 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnerqySoft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 4 of 5 Reg: 211-N0035813A-000000000-0000 Registration Date/Time: 2011/07/19 14:56:15 HERS Provider: CalCERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 7/19/2011 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name White Casita Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/19/2011 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existing Altered Removed Volume Year Built Casita Casita 694 6,940 WA Totals 6941 14,�S0 HVAC SYSTEMS 11� System Name Qty. Heating Type Min. Eff. Cooling'Irype Thermostat T e Status Casita1 Central Furnace 80% AFUE Split Air Con' ttioner Setback New n 1517r. HVAC DISTRIBUTION r i _�► - r !~ `1 +y�. Duct .:= Ducts`z System Name Heating- ' ^ CooJ� - Duct Location R -Value Tested? Status Casita _ Ducted Ducted "Attic, Ceiling Ins, vented 8.0 m New ❑ WATER HEATING SYSTEMS /- Sstem Name l�`Q t .. T e Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A. 0. SMITH FPS -50- 4 SmalPGas All Pipes Ins 43,000 50 0.63 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 m �0 � Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-07-19711:42:36 ID: Page 5 of 5 Reg: 211-N0035813A-000000000-0000 Registration Date/Time: 2011/07/19 14:56:15 HERS Provider: CalCERTS, Inc W -eights Weight Of Materials - Roof and Rigid Insulation Approximate Weights of Floor Requirements Temlock 0" thick) 1.2 psf Trus Jolst'Products Refer.to local' building -code for live load Cork 0.7 psf design requirements. 45" plywood Gold bond • 1.5.psf 2.3P sf 1%" plywood Styrofoam 0.2 psf 2.3 psf 2" decking Foamglass 0.8 psf 7.0 psf 4" decking Rigid fibergias . 1.5 psf Composition Roofing IbsJL.F. TJ160 Truss' 4.75 to 5.75 2-15 Ib. and 1-90 Ib. 1.7 psf / 8 to 9 IbsJL.F. 3:15 and 190 Ib. 3 -ply and gravel . 2.2 psf 5.6 psfRock,wool Roll or Batt Insulation X109: 4 -ply and gravel 6.0 psf (1" thick) 0.2 psf 5 -ply and -gravel 6.5 psf p Glass wool 1 Wick)0.3 psf IRMA (Insulated Roof : 28.6 ' ALPOL (1"thick) 0.1 psf Membrane Assembly) -2" 13.0 psf : • - Single -ply roofs (Insulation not -included) Ballasted t syo em 13.0 psf Floors Mechanically fastened -2.0 psf Hardwood (Norrinal 1") 4.0 psf Fully adhered 2.0 psf Concrete (1" thick): Fir Sheathing (Based on 36 pcf) %"' plywood 1.1 psf mod 15osf 45" plywood 1.8 psf plywood 2.3P sf 1%" plywood 3.4-psf 1" sheathing " 2.3 psf 2" decking 4.3 psf 3" decking 7.0 psf 4" decking 9.3 psf Miscellaneous Decking.Materlals Poured gypsum '(1" thick) 6.5'psf Vermiculite concrete (1"thick) 2.6 psf Corrugated galvanized steel 16 ga. 2.9 psf 20 ga. 1.8 psf 22 ga. 1.5 psf 24 ga. 1.3 psf Asphalt shingles 2:5 psf Wood shingles 2.0 psf Clay tile 9.0 to 14.0 psf TILE Regular Lightweight Linoleum or soft•tile N" ceramic or quarry tile GYP -CRETE (Vi") Ceilings Acoustical fiber tile %;, gypsum board gy a d Plaster (1" thick) Metal suspension system (including tile) Wood suspension system (including tile) • 12.0 psf. 6.0 to 10.0 psf 1.5 psf 10.0 psf 6.5 psf 1.0 psf 2.2 psf psf 8.0 psf 1.8 psf 2.5 psf _TZ.. �o�F1Ti.6 My l�br mac. .le;r 12.4 . N SOL. ST, TWE -11 -TILE DIMENSIONS, INSTALLED WEIGHTS • Lis-rtt;c� :. 1G0 M60i2c q `n tz 4S,TALLED DRY WEIGHT' (psf) /D•7 PSN TJI 25 Joist • TJI 25S Joist. 1.9 to 2.0 22 to 2.4 IbsJLF. IbsJLF. TJI35 Joist TJI35SJoist 24 to 3.3 '3.1 to 4.0 IbsJLE lbsJL.F. TJI 35k Joist 2.8 to 4.0 IbsJL.F. TJI 55 Joist 4.5 to 63 IbsJL.F. TJ145S.Jolst •.:. 4.0 to 7.0 IbslLF. TJL, TJLX Truss .; 3.75 to 4.25 IbsJLF- TJ/50 Truss : • 4 to 5 IbsJL.F. TJ160 Truss' 4.75 to 5.75 IbsJL.F. TJM Truss ' / 8 to 9 IbsJL.F. TJH Truss 10 to 12 lbs./LF. Fir Framing Members Weight of Sprinkler Systems Six e of Pipe Schedule 40, Std. Pipe I Dry(PIQ We1019 Schedule 10, Thin Wap Dry (P11) Wel(pin 1<'•: 1.7. 21- 3.0 2.7 . 3.6 • 3.7 52 2.7 3.8 2)4'".; , •%': 5.8 ; ' 7.9 3,5 ' 5.9 . 7.6 10.8 1 4.3 .',. 8 0 9Ye' v`'; 92: •' 13.5 : 5.0 a 112' 4:;i X109: 16.4, 5.6,', 14.5• i 14.8 23.5:. 7.8 ::.' 20.0 ''31.7...;'• 9.3'': 262`. : 28.6 ' 's 50.8• 16.9: 10„ - ',•' 40.5 s• ' . 74.6•. : •