Loading...
07-2801 (SFD) Revision 1 Title 2414 I TITLE 24 REPORT I Title 24 Report for: Della Penta Residence 53-840 Del Gato Dr. La Quinta, CA 92253 Project Designer: Kristi Hanson Architect 72-185 Painters Path #A Palm Desert, CA 92260 760-776-4068 Report Prepared By: Gina Rose EQS, Inc. 42335 Washington St. #F330 Palm Desert, CA 92211 (760) 674-2345 CSS •Z01 6Tf'ic , CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT, APPROVED FOR CONSTRUCTION 1 M.M461-1.ft I Date: APR 10 2009 Il� vT. kvisw+ls To R�Ekwlie. Barr 4/10/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 5862 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 13 15 16 23 30 38 L EnergyPro 4.4 by EnergySoft Job Number: User Number: 5862 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R n_eUapenta Residence Project Title 1elsato nr La Qilinta n/a ft2 4/10/2009 Date .93-840 Project Address ft2 Slab on Grade Area: 9,050 Building Permit # FCJS Inr. 11.4 ft (760) 674-2345 1.00 Documentation Author Number of Stories: 2 Telephone Plan Check/Date FneraVPrn Comply' race Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.17 3.86 -1.69 Space Cooling 62.40 47.94 14.46 Fans 8.52 6.90 1.62 Domestic Hot Water 2.67 1.92 0.75 Pumps 0.00 0.00 0.00 Totals 75.76 60.63 15.13 Pe Building Type: [ja Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (S)180 deg Natural Gas Area: 1,737 ft2 Avg. U: 0.35 Ratio: 19.2% Avg. SHGC: 0.36 20.0% Total Conditioned Floor Area: 9,050 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 345 ft2 Slab on Grade Area: 9,050 ft2 Average Ceiling Height: 11.4 ft Number of Dwelling Units: 1.00 Number of Stories: 2 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units r,nrnqe #1 An R �6 080 —0 07 Flertric Rm 135 1,350 n o1 Garage #2 758 7 580 0 OR Master Suite 1,434 15 057 0_16 OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt MA Wnnd 34 n n74 R_19 R -n n n An nnor None 48 0 700 None RR -0.0 —Q 90 Door None 48 0.700 None -n 0 n 90 Wall Wnnd 310 n 074R_1 qR_n o An gn Wall Wnnd 82 0.074R-19 R-0 0 —180 An nonr None 144 0 50.0_ Nnnp R -f) iL 180 90 Wall Wind 310 _0_074 R-19 R n n 270 AQ Wall Wnnd 110 _0.074R-19 R n n _n_ An Wall Wood 100 _ n n74 R-19 R-0 0 go 90 Wall Wood 219 x_074 _ R-19 13_0 0 90 Door None 24 0SQd Nnne R -n 0 _n An Wall Wnnd 90 0074R-19 R=n n gn An Wall Wnnd 250 0.074R-19 R-0_ ign go Wall Wood 1080774 R_19 RR -0.0 770 AQ Dow None 144 0.700 None R 0 0 _270 gn Roof Wood 1,433 n n59 Nnnp -;)n () n Q Wall Wnnd 187 n 074 R_19 R-0 0 n AQ Wall Wnnd 887 0074 R_19 _$-0 PQ _9Q Wall Wnnd 32 —o 074 R -1q R -o n 180 An Wall Wnod 210 x074 R_19 R-0 0 . 270 Ao Roof Wnnd 345 Q 051 R_19 R-0.0 _ n 0 Wall Wood 238 0074 R-19 R-0 0 n 99Q Wall Wood 238 0 074 R_19 R- 0_ qaAQ Wall Wnnd 190 0074 R_1q_R-n0 ign An Door Nnnp 24 n 5nn Nnnp R -n 0 180 _90 Thermostat Vent Zone Type Type Hgt. Area Conditioned Sethack— 8 n/a Cnnditinned Setback— _8 n/a Conditioned Setback 8 n/a SleepingIke ,piugStat 8 n/ Gains Condition Y / N Status JA IV Reference Location / Comments New 09-A5 GaragP #1 New 28-A2 GaragP #1 New 28-A2 GaragP #1 New 09-A5 GaragP 41 New 09-A5 Garage #1 New 28-A4 GaragP #1 New 09-A5 Garane #1 New 09-A5 Flertrir Rm New 09-A5 Ete.ctrir Rm New 09-A5 GaragP #2 New 2R -A4 garage #2 New n9 -A5 GaragP #7 New 09-A5 Garage #7 New 09 -AS Garage #2 New 28-A2 Garage #2 New 02-A1 Macter Suite New 119-A5 MngtPr SrlltP New O9 -A$ MaatPr Suitt - New Dg -A5 Macter SiiitP- New 09-A5 Macter Suit - New 02-A5 nnwn Stairs New 09 -AS Dnwn Stairs New MAS nnwn Stairs New n9 -A5 nnwn ctairs New 2R -A4 nnwn $tairs EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:3 of 47 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R nPlIa yenta Residence 9,050 ft2 Existing Floor Area: 4/10/2009 Date Project Title 53-840 Del Cato nr 1 a Qijinta ft2 Slab on Grade Area: Project Address ft2 Average Ceiling Height: 11.4 Building Permit # FOS, Inc_ 1.00 [X (760) 674-2345 2 Documentation Author ® ® ® ® EX ® ® EK EX pI Imo! ❑New El ❑ ❑New ❑New ❑New ❑New ❑X El ❑ ❑New Telephone Plan Check/Date FneravPrn Compff6ce Method Roof Wood 1 096 0 059 Nnne R90 0 n o Wall Wnnd 150 n o74 R-19 R—n n _o qn Wall Wood— 386 nn74 R-19 R -n n An 90 Wall Wnnd 364 0 o74 R-19 R 0-0 180 —o Wall Wood 337 0 074 R_19 R_n n 270 _go CA Climate 7nne 15 Climate Zone Field Check/Date New09-A5 Guest Casita TDV Standard Proposed - Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.17 3.86 -1.69 Space Cooling 62.40 47.94 14.46 Fans 8.52 6.90 1.62 Domestic Hot Water 2.67 1.92 0.75 Pumps 0.00 0.00 0.00 Totals 75.76 60.63 15.13 Percent better than Standard: 20.0% Building Type: W Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (S)180 deg Natural Gas Area: 1,737 ft2 Avg. U: Ratio: 19.2% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name Floor Area Living/Family/Dying 4�631 Guest'Bedroom 1 39n Guest Casita 1 096 0.35 0.36 Volume Total Conditioned Floor Area: 9,050 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 345 ft2 Slab on Grade Area: 9,050 ft2 Average Ceiling Height: 11.4 ft Number of Dwelling Units: 1.00 [X Number of Stories: 2 Roof Wood 4 3( 13 n n52 None R-90 n n n Wall Wnnd 60 nn74 R-19 R -n 0 gn Wall Wnnd 337 0074 R-19 R_0 Q_ gn gn Wall Wood 293 0 074 —$-9 —Q O_ I$Q gn Wall Wood 163 _0074—R-120_0 9981 9 Wall Wood 445 n n74 R-19 R -O o AZO 90 Wall Wood 404 n n74 R-19 R-0 n 315 90 Roof Wnnd 390 0 059 dope_ R -2n 0 0 n Wall Wnnd 10 0 074 R_19 R-0 0 0 go Wall Wnnd 95 0-074 _$19_ 0 1 flfl go Wall Wnnd 252 0 074 R_19 R-00 270 — 90 # of Units OPAQUE SURFACES Insulation Act. Gains Condition Zone Type I wing Sleeping Sleeping Thermostat Type I ivingStat _SIePp Stat SleeninaStat Vent Hgt. Area —8 n/a n/a 8 n/a Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wall Wnnd 214 _o n74 R -1q R_n n 970 -qp Door Nnne 240 F00 _ None R n 0 970 go ® ® ❑Neu- El 09-A5 nnwn Stairs New 28-A4 Down Stairs 21-A4 I wing/Famil ini g Flonr Wnnd 345 0-048 _ R19 _ R0-0 _0_x$0 ❑ IXNew Wall— Wood 2nn n r74 R_19 R_() 0 45 q ® ❑New o9 -AS I iving/Family/Dining Wall Wood 113 0 074 , R-19 R-0(_135 SO [X ❑New 09-A5 ivin8/Fami y/Dini Roof Wood 4 3( 13 n n52 None R-90 n n n Wall Wnnd 60 nn74 R-19 R -n 0 gn Wall Wnnd 337 0074 R-19 R_0 Q_ gn gn Wall Wood 293 0 074 —$-9 —Q O_ I$Q gn Wall Wood 163 _0074—R-120_0 9981 9 Wall Wood 445 n n74 R-19 R -O o AZO 90 Wall Wood 404 n n74 R-19 R-0 n 315 90 Roof Wnnd 390 0 059 dope_ R -2n 0 0 n Wall Wnnd 10 0 074 R_19 R-0 0 0 go Wall Wnnd 95 0-074 _$19_ 0 1 flfl go Wall Wnnd 252 0 074 R_19 R-00 270 — 90 ® ® ® ® EX ® ® EK EX pI Imo! ❑New El ❑ ❑New ❑New ❑New ❑New ❑X El ❑ ❑New 02-A1 I wing Family/Dining New n9 -A5 living/Family pining New o,Q-A5 I wing/Family/Dining 09-A5 I ivina/Family/Dining 09-A5 I ivingLJ amity/Dining n9 -A5 I wing/Famil___v/Dining n9 -A5 I wing/FamilyfLli�g Mew 02-A1 Guest Bedroom 1 New— n9 -A5 Guest Bedroom 1 New 09-A5 Guest Bedroom 1 09-A5 Guest R rimom 1 Roof Wood 1 096 0 059 Nnne R90 0 n o Wall Wnnd 150 n o74 R-19 R—n n _o qn Wall Wood— 386 nn74 R-19 R -n n An 90 Wall Wnnd 364 0 o74 R-19 R 0-0 180 —o Wall Wood 337 0 074 R_19 R_n n 270 _go ® ® ® ® X ❑New ❑New ❑ El El 02-A1 Guest Casita n9 -A5 wast Casita New 09-A5 west Casita New 09-A5 Guest C]as_ita -- New09-A5 Guest Casita ❑ ❑ -- ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:4 of 47 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Della Penta Residence 4/10/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area LI -Factor" SHGCZ Azm. Tilt Stat. Glazing Type Comments 1 Window Front (S) 240_ 034 NFRC 03 NFRC. 180 _90_ New French Dnors C'a=e #1 2 Skylight Rear (N) 0.5 0.550 NFRC 0_67 NFRC 0 0 New Skylight Master Suite 3 Skylight Rear (N) 0.5 0.550 NFRC 0_67 NFRC 0 0 New Slight Master Suite 4 Window Rear (N) 60.0 0.340 NFRC 0.36 NFRC 0 90 New French Doors Master Suite 5 Window Rear (N) 28.3 0.340 NFRC 0.29 NFRC 0 90 New Casement Master Suite 6 Window Rear (N) 28.3 0.340 NFRC0 29 NFRC 0 90 New Casement Master Suite .L Window Right (E) 10.0 0.340 NFRC 0.29 NFRC 90 90 New Casement Master Suite 8 Window Right (E) 67.5 0.380 NFRC 0.35 NFRC 90 90 New Sliding Pocket Doors Master Suite 3 Window Right (Fa 65.9 0.340 NFRC 0.43 NFRC 90 90 New Fixed Master Suite 1Q Window Right (Fa 10.0 0.340 NFRC 0.29 NFRC 90_ 90 New _Casement Master Suite Al Window Front (S) 24.0 0.340 NFRC0 26 NFRC 180 90 New French Doors Down Stairs 12 Window Rear (NE) 100.0 0.380 NFRC .0_35 NFRC 45 90 New Sliding Pocket Doors Living/Family/Dining -ta 14 Window Window Rear Right (N) (E) 240.0 0.380 NFRC 0.35 NFRC 0 _90_ New Sliding Pocket Doors 45.0 0.340 NFRC 0_29 NFRC 90 90 New Casement Living/Family/Dini g Living/Family/Dining 15 Window Right (E) 7.0 0.340 NFRC 0_43 NFRC 90 90 New Fixed Living/Family/Dining 16 Window Right (E) 32.8 0.340 NFRC 0_43 NFRC 90 90 New Fixed Living/Family/Dining 17 Window Right (E) 28.0 0.340 NFRC 0_43 NFRC 90 90 New Fixed Living/Family/Dining 18 Window Front (S) 7.0 0.340 NFRC 0_43 NFRC 180 90 New Fixed Living/Family/Dining -12 Window Front (S) 32.8 0-340 NFRC _,43 NFRC 180 90 New Rxed Living/Family/Dining 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING 100 Area Thick. Heat 26-A1 Inside Garage #1 Condition Location/ Type 26-A1 (sf) (in.) Cap. Cond. R -Val. JA IV Reference Window Overhang Concrete, Heavyweight Left Fin 4.00 Right Fin 0 # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.00 28 0.98 0 26-A1 New Garage #2 / Slab on Grade Concrete, Heavyweight 570 2 None 1.00 0 26-A1 New Master Suite / Slab on Grade Concrete, Heavyweight 864 4.00 28 0.98 3 None 1.00 Master Suite / Slab on Grade 4 Bug Screen 0.76 10.0 6.0 2.0 01 9-0 2.0 5 Bug Screen 0.76 10.0 2.8 2.0 01 2.0 2.0 0.1 2.0 0 0.0 0.0 0 6 Bug Screen 0.76 10.0 2.8 2.0 0 9.0 2.0 0.0 0. 0- --2.0 0 7 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.1 2.0 0 8 Bug Screen 0.76 60.0 6.8 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.4 7.8 2.0 0.1 2.0 2.0 0.1 4.0 0 0.0 0.0 0 10 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 12 Bug Screen 0.76 10.0 10.0 6.0 0.1 6.0 6.0 0.1 4.0 0 0.0 0.0 0 13 Bug Screen 0.76 12.0 20.0 10.0 0.1 10.0 10.0 0.1 4.0 0 0.1 4.0 0 14 Bug Screen 0.76 6.5 6.0 0.1 2.0 0 0.0 0.0 0 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 7.0 4.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 3.5 2.0 4.0 0.1 4.0 4.0 19 Bug Screen 0.76 6.5 4.4 0.0 0.0 0 0.1 4.0 0 THERMAL MASS FOR HIGH MASS DESIGN PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 100 Area Thick. Heat 26-A1 Inside Garage #1 Condition Location/ Type 26-A1 (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight Garage #2 606 4.00 28 0.98 0 26-A1 New Garage #1 / Slab on Grade Concrete, Heavyweight 135 4.00 28 0.98 0 26-A1 New Electric Rm / Slab on Grade Concrete, Heavyweight 758 4.00 28 0.98 0 26-A1 New Garage #2 / Slab on Grade Concrete, Heavyweight 570 4.00 28 0.98 0 26-A1 New Master Suite / Slab on Grade Concrete, Heavyweight 864 4.00 28 0.98 2 26-A1 New Master Suite / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 100 None No Insulation 26-A1 New Garage #1 Slab Perimeter 100 None No Insulation 26-A1 New Electric Rm Slab Perimeter 83 None No Insulation 26-A1 New Garage #2 Slab Perimeter 22 None No Insulation 26-A1 New Master Suite Slab Perimeter 88 None No Insulation 26-A1 New Master Suite Run Initiation Time: 04/10109 11.10:30 Run Code: 1239387 30 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:5 of 47 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Della Penta Residence Project Title 4/10/2009 Date FENESTRATION SURFACES True Cond. # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments 20. Window Front (S) 2n 1ao NFRC DA3 KIFRC Igo _9p_ New Fixed I iving/Fa ily/Dining 21 Window Front (S) 60.0 0.340 NFRC 0_36 NFRC 180 90 New French Doors Living/Family/Dining 22 Window Front (S) 39.2 0.340 NFRC 0_43 NFRC 180 90 New Fixed Living/Family/Dining 23 Window Front (S) 32.8 0.340 NFRC 0_43 NFRC 180 90 New Fixed Living/Family/Dining 24 Window Front (S) 24.0 0.340 NFRC 0_36 NFRC 180 90 New French Doors Living/Family/Dining 25 Window Front U 7.0 0_340 NFRC0 43 NFRC 180 90New Fixed Living/Family/Dining .2E Window Front (,S) _ 40.0 0-340 NERC JOLN NERC 180 _9.0 New French Doors Living/Family/Dining 27 Window Left (W) 45.0 0.340 NFRC 0_29 NFRC 270 90 New Casement Living/Family/Dining 2$ Window Left (OL) 7.0 0_340 NFRC 0_43 NFRC 270 90 New Fixed UvengLEamiWDinanq 29. Window Left (VV) 32.8 _ 0_340NERCQ43 NFRC 270 90 New Fixed Living/Family/Dining ,Q Window Left M) 7.0 0_340 NFRC 0_43 NFRC 270 90 New Fixed Living/Family/Dining 31 Window Left (W) 13.5 0.340 NFRC 0_29 NFRC 270 90 New Casement Living/Family/Dining Screen Window Left (NW) 24.0 0_340 NFRC 0_36 NFRC 315 --9j0_ New French Doors - iving Family/Dini g 33 Window Left (NW) 35.0 0.340 NFRC 0_29 NFRC 315 90 New Casement Living/Family/Dining 34 Window Left (NW) 200.0 0.380 NFRC 0_35 NFRC 315 90 New Sliding Pocket Doors Living/Family/Dining 35 Window Front (S) 48.0 0.340 NFRC 0_36 NFRC 180 90 New French Doors Guest Bedroom 1 36 Window Left (W) 8.0 0.340 NFRC 0_29 NFRC 270 90 New Casement Guest Bedroom 1 3 Window Left (W) 8.0 0.340 NFRC 0_29 NFRC 270 90 New Casement Guest Bedroom 1 -a$ Window Left (p() 8.0 0_340 NFRC 0_29NFRC270 90 New Casement Guest Bedroom 1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 328 4.00 28 0.98 2 26-A1 New Down Stairs / Slab on Grade Concrete, Heavyweight Window 4.00 28 0.98 0 Overhang New Left Fin Right Fin 345 # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 10.0 3.9 8.0 0.1 8.0 8.0 0.0 0.0 0 0.1 4.0 0 21 Bug Screen 0.76 10.0 6.0 6.0 0.1 6.0 6.0 New Down Stairs Slab Perimeter 22 Bug Screen 0.76 10.0 3.9 6.0 0.1 6.0 6.0 0.1 4.0 0 0.0 0.0 0 23 Bug Screen 0.76 6.5 4.4 0.1 4.0 24 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 3.5 2.0 4.0 0. 4.0 4-0 26 Bug Screen 0.76 8.0 5.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 6.5 6.0 0.0 0.0 0 0.1 4.0 0 28 Bug Screen 0.76 3.5 2.0 4.0 0.1 4.0 4.0 29 Bug Screen 0.76 30 Bug Screen 0.76 3.5 2.0 2.0 0.1 2.0 2.0 31 Bug Screen 0.76 32 Bug Screen 0.76 _ 33 Bug Screen 0.76 7.0 5.0 8.0 0.1 8.0 8.0 34 Bug Screen 0.76 10.0 20.0 8.0 0.1 8.0 8.0 35 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 _ _ 36 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 _ 37 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 _ 38 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 328 4.00 28 0.98 2 26-A1 New Down Stairs / Slab on Grade Concrete, Heavyweight 3.958 4.00 28 0.98 0 26-A1 New Living/Family/Dining / Slab on Grade Concrete, Heavyweight 345 4.00 28 0_98 2 26-A1 New Living/Family/Dining / Slab on Grade Concrete, Heavyweight 276 4.00 28 0_98 2 26-A1 New Guest Bedroom 1 / Slab on Grade Concrete, Heavyweight 114 4.00 28 0.98 0 26-A1 New Guest Bedroom 1 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 76 None No Insulation 26-A1 New Down Stairs Slab Perimeter 237 None No Insulation 26-A1 New Living/Family/Dining Slab Perimeter 26 None No Insulation 26-A1 New Living/Family/Dining Slab Perimeter 30 None No Insulation 26-A1 New Guest Bedroom 1 Slab Perimeter 15 None No Insulation 26-A1 New Guest Bedroom 1 Run Initiation Time: 04/10/09 11.10.30 Run Code: 1239387030 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:6 of 47 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Della Penta Residence 4/10/2009 Project Title Date FENESTRATION SURFACES Window Hgt. Wd. Len. Overhang Hgt. LExt. Left Fin Right Fin RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 True Cond. Location/ # Type 6.0 2.0 Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments 3.9. Window Right (E) 300 034 NERC 0-29 NERC 90_ -90_ New Casement Guest Casita 40 Window Right (E) 42.0 0.340 NFRC 0_29 NFRC 90 90 New Casement Guest Casita 4 Window Right (E) 25.0 0.340 NFRC 0_29 NFRC 90 90 New Casement Guest Casita 42 Window Front (S) 7.0 0.340 NFRC 0_43 NFRC 180 90 New Fixed Guest Casita 43 Window Front (S) 7.0 0.340 NFRC 0_43 NFRC 180 90 New Fixed Guest Casita 44 Window Left (W) 5.3 0.340 NFRC 0_29 NFRC 270 90 New Casement Guest Casita A5 Window Left (W) 5.3 0-34 NFRC-.22 NFRC 270 _90 New Casement Guest Casita 46 Window Left (W) 32.5 0.340 NFRC 0.43 NFRC 270 90 New Fixed Guest Casita A7 Window Left (W) 32.5 0.34Q NFRC-4.3 NFRC 270 90 New Eixed Guest Casita -.8. Window Left (W) 60.0 0.340 NFRC 0.36 NFRC -970 -90 New French Doors Guest Casita 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Len. Overhang Hgt. LExt. Left Fin Right Fin RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen . 0.76 5.0 6.0 2.0 0.1 2.0 2.0 40 Bug Screen 0.76 7.0 6.0 4.0 0.1 4.0 4.0 0.1 2.0 0 0.1 2.0 0 41 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 42 Bug Screen 0.76 3.5 2.0 2.0 .1 .o 9.0 43 Bug Screen 0.76 3.5 2.0 2.0 0.1 2.0 2.0 44 Bug Screen 0.76 3.5 1.5 2.0 0. 9.0 7.0 45 Bug Screen 0.76 3.5 1.5 2.0 0.1 2.0 2.0 46 Bug Screen 0.76 10.0 3.2 8.0 0.1 8.0 8.0 47 Bug Screen 0.76 10.0 3.2 8.0 0.1 8.0 8.0 48 Bug Screen 0.76 10.0 6.0 8.0 0.1 8.0 8.0 THERMAL MASS FOR HIGH MASS DESIGN Run Initiation Time: 04/10/09 11:10:30 Run Code: 1239387030 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:7 of 47 J Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 655 4.00 28 0_98 0 26-A1 New Guest Casita / Slab on Grade Concrete, Heavyweight 441 4.00 28 0_98 2 26-A1 New Guest Casita / Slab on Grade Insulation Location/ Condition PERIMETER LOSSES Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 70 None No Insulation 26-A1 New Guest Casita Slab Perimeter 51 None No Insulation 26-A1 New Guest Casita Run Initiation Time: 04/10/09 11:10:30 Run Code: 1239387030 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:7 of 47 J Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Della Penta Residence Tank Energy Tank Insul. 4/10/2009 Project Title Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) Date Status or RE HVAC SYSTEMS A.O. SMITH FPS -75-230 Small Gas All Pipes Ins 2 75,000 75 New 0.88 n/a n/a Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Garage #1 None n/a Room PTAC without Side 11.6 EER New Setback Electric Rm None n/a PRRrP C without Side 11.8 EER New Setback Garage #2 None n/a % gYffrPTAC without Side 11.8 EER New Setback Louvers HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Coolinq Location R -Value Status Tested? Garage #1 Ductless/ with Electric Rm tless / with Garage #2 BRiless / with Fan Ductless n/a Ductless n/a Ductless n/a Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. n/a New Yes n/a New Yes n/a New Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A.O. SMITH FPS -75-230 Small Gas All Pipes Ins 2 75,000 75 New 0.88 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Name: Title/Firm: Address: Telephone: (signature) (date) User Number: 5862 Documentation Author Name: Gina Rose Title/Firm: EQS Inc. Address: 42335 Washington St. #F330 Palm Desert, CA 92211 Telephone: 7600 674-234 42 4 (si'gnature) (date) Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Della Penta Residence Duct Duct Condition 4/10/2009 Project Title Heating Cooling Location Date Tested? Master Suite HVAC SYSTEMS Ducted Conditioned 4.2 New Yes Living/Family/Dining Ducted Ducted Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Master Suite Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Living/Family/Dining Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Guest Bedroom 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Kristi Hanson Architect Address: 72-1 5 Painters Path #A I DesertCA 92260 Telephon 0 76-4068 Lic. #: (signaturU)V '^ I (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Gina Rose Title/Firm: EQS Inc. Address: 42335 Washington St. #F330 Palm Desert, CA 92211 Teleph 760 674-23 ` v r signature) (date) Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Master Suite Ducted Ducted Conditioned 4.2 New Yes Living/Family/Dining Ducted Ducted Conditioned 4.2 New Yes Guest Bedroom 1 Ducted Ducted Conditioned 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Kristi Hanson Architect Address: 72-1 5 Painters Path #A I DesertCA 92260 Telephon 0 76-4068 Lic. #: (signaturU)V '^ I (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Gina Rose Title/Firm: EQS Inc. Address: 42335 Washington St. #F330 Palm Desert, CA 92211 Teleph 760 674-23 ` v r signature) (date) Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Della Penta Residence 4/10/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Guest Casita Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Guest Casita Ducted Ducted Conditioned 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement lhem.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Kristi Hanson Architect Address: 72-185 Painters Path #A Im Desert 0 rnTeleph 0-776-4A�CA Lic. #: (sign ) (date) UV Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Gina Rose Title/Firm: EQS.Inc. Address: 42335 Washington St. #F330 Palm Desert, CA 92211 Telephone: 175QY07472345 n /0A) (signature) dat) I EneravPro 4.4 by EneravSoft User Number: 5862 Job Number: Page: 10 of 47 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Della Penta Residence 4/10/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field HIGH MASS Design - Thermal Mass: 606 sqft Exposed Slab Floor, 4.00" thick at Garage #1 HIGH MASS Design - Thermal Mass: 135 sqft Exposed Slab Floor, 4.00" thick at Electric Rm HIGH MASS Design - Thermal Mass: 758 sqft Exposed Slab Floor, 4.00" thick at Garage #2 The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. This house has reduced infiltration and/or mechanical ventilation. The homeowner's manual provided by the builder must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HIGH MASS Design - Thermal Mass: 570 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design - Thermal Mass: 864 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "Living/Family/Dining" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. This house has reduced infiltration and/or mechanical ventilation. The homeowner's manual provided by the builder must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HIGH MASS Design - Thermal Mass: 328 sqft Covered Slab Floor, 4.00" thick at Down Stairs HIGH MASS Design - Thermal Mass: 3958 sqft Exposed Slab Floor, 4.00" thick at Living/Family/Dining HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "Garage #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "Electric Rm" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "Garage #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "Master Suite" has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System "Master Suite" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "Master Suite" incorporates a HERS verified Refrigerant Charge test or"a HERS verified Thermostatic Expansion Valve. This building has tight construction with reduced infiltration and a target blower door test range between 563 and 451 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 563 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. WARNING - Buildings with reduced infiltration are prohibited from having vented combustion appliances other than cooking appliances, refrigerators and domestic clothes dryers that use indoor air for combustion inside conditioned space. The HVAC System "Living/Family/Dining" has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System "Living/Family/Dining" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Living/Family/Dining" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has tight construction with reduced infiltration and a target blower door test range between 1819 and 1455 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 1819 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. EnergyPro 4.4 by EnergvSoft User Number: 5862 Job Number: Page:11 of 47 I Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Della Penta Residence 4/10/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted.Pll an I Field HIGH MASS Design - Thermal Mass: 345 sqft Covered Slab Floor, 4.00" thick at Living/Family/Dining The HVAC System "Guest Bedroom 1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. This house has reduced infiltration and/or mechanical ventilation. The homeowner's manual provided by the builder must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HIGH MASS Design - Thermal Mass: 276 sqft Covered Slab Floor, 4.00" thick at Guest Bedroom 1 HIGH MASS Design - Thermal Mass: 114 sqft Exposed Slab Floor, 4.00" thick at Guest Bedroom 1 The HVAC System "Guest Casita" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. This house has reduced infiltration and/or mechanical ventilation. The homeowner's manual provided by the builder must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HIGH MASS Design - Thermal Mass: 655 sqft Exposed Slab Floor, 4.00" thick at Guest Casita HIGH MASS Design - Thermal Mass: 441 sqft Covered Slab Floor, 4.00" thick at Guest Casita HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan I Field WARNING - Buildings with reduced infiltration are prohibited from having vented combustion appliances other than cooking appliances, refrigerators and domestic clothes dryers that use indoor air for combustion inside conditioned space. The HVAC System "Guest Bedroom 1" has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System "Guest Bedroom 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on th CF -4R. The HVAC System "Guest Bedroom 1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has tight construction with reduced infiltration and a target blower door test range between 153 and 123 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 153 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SIA=1.5) OR mechanical supply ventilation must be provided. WARNING - Buildings with reduced infiltration are prohibited from having vented combustion appliances other than cooking appliances, refrigerators and domestic clothes dryers that use indoor air for combustion inside conditioned space. The HVAC System "Guest Casita" has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System "Guest Casita" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF 4R. The HVAC System "Guest Casita" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has tight construction with reduced infiltration and a target blower door test range between 430 and 344 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining -Air Leakage Rate. WARNING - If this building tests below 430 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. WARNING - Buildings with reduced infiltration are prohibited from having vented combustion appliances other than cooking appliances, refrigerators and domestic clothes dryers that use indoor air for combustion inside conditioned space. I EnergyPro 4.4 by EnergvSoft User Number: 5862 Job Number: Page:12 of 47 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ f§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ .§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ E ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 permfinch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ - ❑ ❑ $ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. ❑ ❑X ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 13 of 47 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk(') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or Initial applicable boxes when completed or check N/A if not ENFORCE- DESCRIPTIONaDDlicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulation's, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanentlinstalled luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ IZ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. El El 1:1Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 14 of 47 Residential Kitchen Lighting Worksheet WS -5R Della Penta Residence 4/10/2009 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined In Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following Information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts High Efficacy Quantity Watts Other Watts (1) 5" Recessed Fluor. Yes X No 18.0 x 8 = 144 or 50w MR16 Yes I No I X 50.0 x 4 = or 200 Fluorescent 6w per ft. Yes X1 No 1 6.0 x 17 = 102 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 246 B: 200 COMPLIES IF A;-). B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 15 of 47 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Garage #1 606 Number of Systems 1 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sgft) 0.0 Cooling System Output per System 12,300 Total Output (Btuh) 12,300 Total Output (Tons) 1.0 Total Output (Btuh/sgft) 20.3 Total Output (sgft/Ton) 591.2 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.65 Airflow (cfm/Ton) 975.6 Outside Air (%) 11.5 Outside Air (cfm/sqft) 0.19 Note: values above given at ARI conditions 26.0 OF Outside Air 115 cfm 70.0 of 111.0 / 72.5 of Outside �� 115 cfm 72.0/60.5 of 4.4 by 64.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM Sensible Latent 1CFM1 Sensible 547 9,904 819 378 14,095 0 0 0 0 0 115 4,771 -125 115 5,385 0 0 0 0 14,6751 694 19 480 Fujitsu-ASU12RMLQ/AOU12RMLQ(2) 6,846 3,640 0 Total Adjusted System Output 6,846 3,640 (Adjusted for Peak Design Conditions) 01 TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am -earn Temperatures at Time of Heatina Peak) 105.0 of Heating Coil 105.0 of (��' -_� Supply Air Ducts Supply Fan 105.0 of 1000 cfm ROOMS 70.0 of Return Air Ducts I ,irstream Temperatures at 76.5 / 62.1 of. 55.0 / 53.8 of User Number: 5862 Cooling Coil of Cool Supply Fan 1000 cfm 55.0 / 53.8 of Supply Air Ducts 55.0/53.8OF 51.9% R.H. ROOMS 72.0 / 60.5 of Return Air Ducts Job Number: 16 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Electric Rm 135 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sgft) 0.0 Cooling System Output per System 9,700 Total Output (Btuh) 9,700 Total Output (Tons) 0.8 Total Output (Btuh/sgft) 71.9 Total Output (sgft/Ton) 167.0 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 7.41 Airflow (cfm/Ton) 1,237.1 Outside Air (%) 11.5 Outside Air (cfm/sgft) 0.85 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 26.0 OF 64.9 OF Outside Air 115 cfm 70.0 of 111.0 / 72.5 of Outside —�—� 115 cfm 72.0 / 60.5 °F 4.4 PSYCHROM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFMTSensiblel Latent I CFM Sensible 17 3,088 804 117 4,342 0 0 0 0 0 115 4,771 -123 115 5,385 0 0 0 1 0 7,8591 68 9 727 Fujitsu-ASU9RMLQ 5,494 2,775 0 Total Adjusted System Output 5,494 2,775 (Adjusted for Peak Design Conditions) 01 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of Heating Coil Supply Fan 1000 cfm 105.0 of -� Supply Air Ducts 105.0 of ROOMS 70.0 OF h Return Air Ducts 76.5/62.10F M 55.0/53.80F User Number: 5862 Cooling Coil Supply Fa 1000 cfm 55.0 / 53.8 of -� Supply Air Ducts Fan 55.0 / 53.8 of 51.9% R.H. ROOMS 72.0 / 60.5 OF Return Air Ducts Job Number: 17 of 47 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Garage #2 758 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sqft) 0.0 Cooling System Output per System 9,700 Total Output (Btuh) 9,700 Total Output (Tons) 0.8 Total Output (Btuh/sqft) 12.8 Total Output (sgftrron) 937.7 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.06 Airflow (cfm/Ton) 989.7 Outside Air (%) 14.4 Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions 26.0 OF Outside Air 115 cfm 70.0 of 111.0 172.5 OF Outside Air 115 cfm 72.0 / 60.5 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 533 9,640 824 330 12,290 0 0 0 0 0 115 4,771 -130 115 5,385 0 0 0 0 14,41 693 17 675 Fujitsu-ASU9CQ/AOU9CQ 6,102 2,217 0 Total Adjusted System Output 6,102 2,217 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 63.7 OF bl 105.0 °F Heating Coil 105.0 OF Supply Air Ducts Supply Fan 105.0 OF 800 cfm ROOMS 70.0 of Return Air Ducts I 77.6 / 62.5 OF . 55.0 / 53.8 OF Cooling Coil Supply Fa 800 cfm 55.0 / 53.8 of -> Supply Air Ducts Fan 55.0 / 53.8 of 51.9% R.H. ROOMS 72.0 / 60.5 of �% Return Air Ducts `i I EneravPro 4.4 by EnerovSoft User Number: 5862 Job Number: Page: 18 of 47 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Master Suite 1,434 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 79,000 Total Output (Btuh) 79,000 Output (Btuh/sgft) 55.1 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 40.4 Total Output (sqf rron) 296.7 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.39 Airflow (cfm/Ton) 413.8 Outside Air (%) 5.8 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 1,057 19,124 814 431 16,072 0 1,208 642 0 0 115 4,701 -106 115 5,348 0 0 1,208 642 26,240 708 TRANE 4TTX4060/TUD100R960 (5) 44,229 4,746 Total Adjusted System Output44,229 4,746 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 79,000 79,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.2 OF 67.2 °F 105.0 OF Supply Air Ducts Outside AirQp; 115 cfm 104.7 OF Supply Fan Heating Coil 2000 cfm ROOMS 69.7 OF 70.0 OF 46 Return Air Ducts OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/72.5°F 74.8/61.4°F 74.8/61.5°F 55.0/53.9°F u e ,r :; Supply Air Ducts Outside Air xQ;_ r_ 115 cfm Supply Fan Cooling Coil 55.6/54.2 °F 2000 cfm 51.7% R.H. ROOMS 72.6/60.7 °F 72.0 / 60.5 OF 4.4 User Number: 5862 Return Air Ducts Job Number: 19 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Living/Family/Dining 4,631 Number of Systems 3 Heating System Output per System 79,000 Total Output (Btuh) 237,000 Output (Btuh/sqft) 51.2 Cooling System Output per System 58,000 Total Output (Btuh) 174,000 Total Output (Tons) 14.5 Total Output (Btuh/sgft) 37.6 Total Output (sgft/Ton) 319.4 Air System CFM per System 2,000 Airflow (cfm) 6,000 Airflow (cfm/sqft) 1.30 Airflow (cfm/Ton) 413.8 Outside Air (%) 3.8 Outside Air (cfm/sgft) 0.05 Note: values above given at ARI conditions EATING SYSTEM PSYCH 26.0 OF 68.0 OF Outside Air 230 cfm 69.7 of 111.0 / 72.5 of Outside 230 cfm 72.6/60.7 of Supply Fan 6000 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1COILHTG.PEAK CFMISensiblel 1,486 Latent 11CFM1Sensible 0 3,415 61,791 1,646 1,486 55,337 0 3,902 2,210 0 0 230 9,392 -186 230 10,685 0 0 3,9021 2,210 78,9871 147591 70 442 TRANE 4TTX4060lrUD100R960 (5) 130,352 15,957 237,000 Total Adjusted System Output 130,352 15,957 237,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 68.0 of 105.0 of Ml Heating Coil Supply Air Ducts 104.7 of ROOMS 70.0 of Return Air Ducts I 74.1 /61.2OF 74.1 /61.2OF. 55.0/53.9OF —1 Supply Fan Cooling Coil 6000 cfm h Return Air Ducts `S Supply Air Ducts 55.6 / 54.2 of 51.5% R.H. ROOMS 72.0 / 60.4 of EnerovPro 4.4 by EneravSoft User Number: 5862 Job Number: Page:20 of 47 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Guest Bedroom 1 390 Number of Svstems 1 1 Heating System Output per System 47,000 Total Output (Btuh) 47,000 Output (Btuh/sgft) 120.5 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 61.5 Total Output (sgft/Ton) 195.0 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 425 7,693 804 134 4,987 0 486 199 0 0 115 4,701 -118 115 5,356 0 0 486 199 13,3651 686 10 742 Air System HVAC EQUIPMENT SELECTION CFM per System 800 TRANE 4TTX4024/TUD60R936 (2) 20,032 595 47,000 Airflow (cfm) 800 Airflow (cfm/sgft) 2.05 Airflow (cfm/Ton) 400.0 (%) Total Adjusted System Output Outside Air 14.4 (Adjusted for Peak Design Conditions) 20,032 595 47,000 Outside Air (cfm/sgft) 0.29 TIME OF SYSTEM PEAK Aug 2 pm I F Jan 12 am Note: values above given at ARI conditions 26.0 OF Outside Air 115 cfm 69.8 OF 111.0 / 72.5 of 4 Outside � 115 cfm 72.6/60.7 of 63.5 OF 63.5 of 105.0 of 1 � Supply Fan Heating Coil 800 cfm �% Return Air Ducts `i 78.1 / 62.6 of 78.1/62.60F 0 55.0/53.70F Supply Fan Cooling Coil 800 cfm )% Return Air Ducts '� Supply Air Ducts 104.8 of ROOMS 70.0 OF Supply Air Ducts 55.6 / 54.0 of 51.8% R.H. ROOMS 72.0 / 60.5 of EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 21 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Guest Casita 1,096 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 79,000 Total Output (Btuh) 79,000 Output (Btuh/sgft) 72.1 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 52.9 Total Output (sgft/Ton) 226.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.82 Airflow (cfm/Ton) 413.8 Outside Air (%) 5.8 Outside Air (cfm/sgft) 0.10 Note: values above given at ARI conditions 26.0 OF Outside Air 115 cfm 69.7 of 111.0 / 72.5 of 311� Outside Air 115 cfm 72.5/60.7 of 67.2 of 67.2 OF --6—i)-1J--4- 26.0 gin1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFMISensbiel Latent 1CFM1 Sensible 918 16,600 81 410 15,265 0 1,048 610 0 0 115 4,710 -108i 115 5,350 0 0 1,048 610 23,4071 703 21 834 TRANE 4TTX4060lrUD100R960 (5) 44,137 4,822 79,000 Total Adjusted System Output aa,137 4,822 79,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of Supply Fan Heating Coil 2000 cfm Supply Fan Cooling Coil 2000 cfm K Return Air Ducts `i Return Air Ducts Supply Air Ducts 104.7 of ROOMS 70.0 of vuNNiy �n vU�LQ 55.5/54.1OF 51.7% R.H. ROOMS 72.0 / 60.5 of EnergyPro 4.4 by EnergvSoft User Number: 5862 Job Number: Pane: 22 of 47 1 FROOM LOAD SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Garage #1 606 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Garage #1 Garage #1 1 547 9,904 819 547 9,904 819 378 14.095 PAGE TOTAL 1 547 9,9041 819 378 14,095 TOTAL 1 547 9,904 819 378 14,095 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: p4; of 47 ROOM LOAD SUMMARY PROJECT NAME Della Penta Residence DATE 4/10/2009 SYSTEM NAME Electric Rm FLOOR AREA 135 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Electric Rm Electric Rm 1 171 3,088 804 171 3,088 804 117 4.342 PAGE TOTAL 1 171 3,088 804 F 117 TOTAL 1 171 3,088 804 117 4,342 4,342 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 24 of 47 ROOM LOAD SUMMARY PROJECT NAME DATE Della Penta Residence 4/10/2009 SYSTEM NAME FLOOR AREA Garage #2 758 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Garage #2 Garage #2 1 533 9,640 824 533 9,640 824 330 12,290 PAGE TOTAL 533 9,640 824 330 12 290 TOTAL 1 533 9,640 824 330 12,290 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 25 of 47 ROOM LOAD SUMMARY -:1 PROJECT NAME Della Penta Residence DATE 4/10/2009 SYSTEM NAME Master Suite FLOOR AREA 1.,434 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite Master Suite 1 1,057 19,124 814 1,057 19,124 814 431 16,072 PAGE TOTAL 1 1,0571 19,124 81411 431 16,072 TOTAL 1 1,057 19,124 814 431 16,072 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 26 of 47 ROOM LOAD SUMMARY PROJECT NAME Della Penta Residence DATE 4/10/2009 SYSTEM NAME Living/Family/Dining FLOOR AREA 4,631 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Down Stairs Down Stairs 1 380 6,873 803 380 6.873 803 210 7,838 Living/Family/Dining1 Living/Family/Dining 3,036 54,918 842 3,036 54,918 842 1,275 47,499 PAGE TOTAL 1 3,415 61,791 1 646 1,4861 55,337 TOTAL 1 3,415 61,791 1 1,486 55,337 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 27 of 47 ROOM LOAD SUMMARY PROJECT NAME Della Penta Residence DATE 4/10/2009 SYSTEM NAME Guest Bedroom 1 FLOOR AREA 390 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZON NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Bedroom 1 Guest Bedroom 1 1 425 7,693 804 425 7,693 804 134 4,987 PAGE TOTAL 1 425 7,693 804 134 F 4 987 TOTAL 1 425 7,693 804 134 4,987 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page:28 of 47 ROOM LOAD SUMMARY PROJECT NAME Della Penta Residence DATE 4/10/2009 SYSTEM NAME Guest Casita FLOOR AREA 1 096 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NA E ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Casita Guest Casita 1 918 16,600 811 918 16.600 811 410 15,265 PAGE TOTAL 1 9181 16,600 8711F --410T 15,265 TOTAL 1 918 16,600 811 410 15,265 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 29 of 47 ROOM HEATING PEAK LOADS 71 Project Title Date Della Penta Residence 4/10/2009 �71 Room Information Des! - n Conditions Room Name Garage#1 Time of Peak Jan 12 am Floor Area 606 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 34.0 x X X x X X X X X x x X x X X X X X X X X x X x x X X X x X x X X x x X X x X 0.0740 X X X x x x x x x x x X X x x X X x X X X X X X X x X x x x X X x X x X X x X 44 = = = = = = = = = = = = = = = = = = = = = = 111 48.0 0.7000 44 1,478 48.0 0.7000 44 1,478 310.0 0.0740 44 1,009 82.0 0.0740 44 267 24.0 0.3400 44 359 144.0 0.5000 44 3,168 310.0 0.0740 44 1,009 perometer=100.0 0,7300 44= 3,212 norma --i wnrt an datenart k ucnutc wnuuctwn unuugn an interior aundoe to dnotrtcr morn. Page Total: 12.092 Infiltration: r 1.. 01 x 1.064 x sos x 10.00 x o.42a 16] x &T = z o03 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,095 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 30 of 47 ROOM HEATING PEAK LOADS Project Title Date Della Penta Residence 4/10/2009 Room Information Desi - n Conditions Room Name Electric Rm Time of Peak Jan 12 am Floor Area 135 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value QT of Btu/hr 110.0 x X X x X X X x x x x X x X x X X X x X X X x x X X X X X X X x X X X X X X x 0.0740 X X X x X X X x X x x X X X x X X X X X X X x X X X x X X X X x X X x x x X X 44 = = = = = = = = = = = = = = = = 358 100.0 0.0740 44 326 perimeter= 100.0 0.7300 44 3,212 items snown with an asterisk () genote conauction through an interior surface to another room. Page Total: I 3.896 Infiltration: r 1.00 X 1.064 x 135 X 10.00 X0.424 / 60 X 44 = 446 `schedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,342 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 31 of 47 ,> , ROOM HEATING PEAK LOADS Project Title Date Della Penta Residence 14/10/2009 Room Information Desi n Conditions Room Name Garage#2 Time of Peak Jan 12 am Floor Area 758 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value Z�T of Btu/hr 216.0 X x X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0740 X X x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 703 24.0 0.5000 44 528 90.0 0.0740 44 293 250.0 0.0740 44 814 106.0 0.0740 44 345 144.0 0.7000 44 4,435 perimeter = 83.0 0.7300 44 2,666 items snown wnn an asterisk () aenote conauction tnrougn an interior surface to anotner room. Page Total: I 9.785 Infiltration: r 1.00 X 1.064 X 758 X 10.00 x 0.424 / 6] x � = 2 505 schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,290. EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 32 of 47 ,. , ROOM HEATING PEAK LOADS Project Title Date Della Penta Residence 14/10/2009 Room Information Desi n Conditions Room Name Master suite Time of Peak Jan 12 am Floor Area 1,434 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr R-20 1,432.9 X X X x X x x X x X X X X X x X x x X X X X x X X X x X X x x X x X x X X X X 0.0522 X x x X x X X x x X X X X X X X x X X X x X X x x X x X X X X X X x x x X X X 44 = = = = = = = = = = = = = = = = = = = = 3,289 0.5 0.5500 44 13 0.5 0.5500 44 13 167.4 0.0740 44 545 60.0 0.3400 44 898 28.3 0.3400 44 423 28.3 0.3400 44 423 686.6 0.0740 44 2,236 10.0 03400. 44 150 67.5 0.3800 44 1,129 65.9 0.3400 44=qRS 10.0 0.3400 44 150 32.0 0.0 40 44 104 210.0 0.0740 44= 684 perimeter = 22.0 0.7300 44 707 erimeter = 88.0 0.7300 44 2,827 Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 14,5751 Infiltration: I1 1.001 x 1.064 x 1 434 x 10.50 x 0.127 / 60] x 0 = 1 497 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,072 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 33 of 47 ROOM HEATING PEAK LOADS :1 Project Title Date Della Penta Residence 4/10/2009 Room Information Desi n Conditions Room Name Down Stairs Time of Peak Jan 12 am Floor Area 328 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T of Btu/hr Wall 345.0 X X X x X X X x X X X X. X x X X X x X X X X X X X x X X X X X X X X X X X XX X 0.0510 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 774 238.0 0.0740 44 775 238.0 0.0740 44 775 190.0 0.0740 44 619 24.0 0.3400 44 359 24.0 0.5000 44 528 214.0 0.0740 44 697 24.0 0.5000 44 528 perimeter= 0,7300 44 2,441 items snown wnn an asterisk (-) denote conduction tnrougn an interior surtace to anotner room. Page Total: i 7,4961 Infiltration: r 1.001 X 1.064 X 328 X 12.50 X 0.107 / 6] X � = 342 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,838 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 34 of 47 ROOM HEATING PEAK LOADS Project Title Date Della Penta Residence 4/10/2009 7 Room Information Desi n Conditions Room Name Living/Family/Dining Time of Peak Jan 12 am Floor Area 4,303 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x x x 44 = = = = = = = = = = = = = = 44 44 44 44 44 44 44 44 44= 44= 44 4 44= 44 44 44 44= 44 4 44= 44 44= 44= 44= 44 44 44= 44= 44= 44= 44 44 44 44 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 43 008 Infiltration: `-S 1.001 x 1.064 x 4 303 x 12.50 x 0.107 / 6 ] x 44 = 4 491 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 47,499 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 35 of 47 1: . / 1 . ROOM HEATING PEAK LOADS Project Title Date Della Penta Residence 4/10/2009 Room Information Desi n Conditions Room Name Guest Bedroom 1 Time of Peak Jan 12 am Floor Area 390 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr perimeter = 30.0 X X X X X X X X X X x- X X X X X x x X X X X x x X X X x X X X X x X X x X X X 0.7300 X X X X X x x X X x x X X X X X X X X X X X X X X X X X X X X X X X X x X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = 964 390.0 0.0522 44 895 10.0 0.0740 44 33 95.0 0.0740 44 309 48.0 0.3400 44 718 252.0 0.0740 44 821 8.0 0.3400 44 120 8.0 0.3400 44 120 8-0 0,3400 44 120 perimeter= 15.0 0.7300 44 482 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 4 580 Infiltration: 1.00 X 1.064 X 390 X 9.50 X 0.141 / 6] X 44 = 407 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,987. EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 36 of 47 I 1 I ROOM HEATING PEAK LOADS Project Title Date Della Penta Residence 4/10/2009 Room Information Desi n Conditions Room Name Guest Casita Time of Peak Jan 12 am Floor Area 1,096 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value 1096.0 X x X X X X X X X x x X X x x X x x x x x x x x x x x x x x x x x x x x x x x 0.0522 x x X X X X X X X x X X X X x X x x x x x x x x x x x x x x x x x x x x x x x 150.0 0.0740 386.0 0.0740 30.0 0.3400 42.0 0.3400 25.0 0.3400 364.0 0.0740 7.0 0.3400 7.0 0,3400 337.4 0.0740 5.3 0.3400 5.3 0.3400 325 0,3 400. 32.5 0,3400 60-0 0.3400 perimeter = 70.0 0.7300 perimeter - OT OF Btu/hr 2.5161 488 1,257 449 628 374 1,185 105 105 1,099 79 79 6 486 AM 2.248 1638 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 121 Infiltration: r 1.00 X 1.064 X 1 096 X 10.50 X 0.127 / 6] X 44 = 1 144 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,265 EnergyPro 4.4 by Energysoft User Number: 5862 Job Number: Page: 37 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 4/10/2009 Room Information Desicin Conditions Room Name: Garage #1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 606 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F opaque aurraces R-20 Wall Hollow Metal Door R-20 Wall R-20 Wall Wood Door R-20 Wall Orientation Area X X X X X X x x x x x x U -Factor X X X X X X x x x x x x CLTD 1 = = = = = = = = = = = = N 34.0 0.0740 23.0 N 96.0 0.7000 23.0 E 310.0 0.0740 33.0 S 82.0 0.0740 26.0 S 144.0 0.5000 26.0 310.0 0.0740 33.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration rage I otal Btulhr Shaded Unshaded Orientation Area GLF Area GLF Btu/hr S 0.0 x 20.2 + 24.0 x 20.2 = 486 x + x = x + x = x + x = x + x = x + x x + x = x + x = x + x = x + x = x + x = Page Total ass Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/occ. = 920 E ui ment FDwelling Units X 1 600 Btuh = 1,60'0 Infiltration: 06 X 24 X 33 6 X 1,751 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,904 Latent Gain Btulhr Occu ants �4 Occupants X 1 2001 Btuh/occ. = 800 Infiltration: 4771 X 1.24 X 33.16 X 0.00010 = 19 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 819 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 38 of 47 .. 4 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 14/10/2009 Room Information Desi n Conditions Room Name: Electric Rm Outdoor Dry Bulb Temperature: 1120F Floor Area: 135 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F ue burraces Orientation Area U -Factor CLTD 1 N 110.0 X 0.0740 X 31.0 = E 100.0 X 0.0740 X 44.0 = x X X X x x X X X X X X = x X x X X X = x X = Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain rage i oval Btulhr 252 326 578 Orientation 4 Shaded Area X x x x x x x x x x x GLF + + + + + + + + + + + Unshaded Area x x x x x x x x x x x Page GLF = = = = = = = = = = = Btu/hr TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,0881 Latent Gain Btulhr Occu ants Occupants x 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.24 x 7.39 x 0.00010 = aJ Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 804 0 Total Btulhr Occupants 4 Occupants X 230 Btuh/oCC. =92:0] E ui ment Dwelling Units X 1 200 Btuh 1 1 200 Infiltration: 064 X x 7 39 X = 3 D Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,0881 Latent Gain Btulhr Occu ants Occupants x 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.24 x 7.39 x 0.00010 = aJ Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 804 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 39 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 4/10/2009 Room Information Desi n Conditions Room Name: Garage #2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 758 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72'FOutdoor Daily Range: 340F Lie Surraces Wall (Hollow Metal Door I Orientation Area X X X X X X x X x x x x U -Factor X X X X X X x X X x X X CLTD 1 = = = = = = = = = N 216.0 0.0740 23.0 N 24.0 0.5000 23.0 E 90.0 0.0740 33.0 S 250.0 0.0740 26.0 W 106.0 0.0740 33.0 W 144.0 0.7000 33.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occu ants 4 E ui ment 1 Nage I otal Btu/hr Shaded Unshaded Orientation Area GLF Area GLF Btu/hr x + x = x + x = x + x = x + x = x + x = X- + x = x + x = x + x = x + x = x + x = x + x = Page Total 0 Btu/hr Occupants x 230 Btuh/occ. = 920 Dwelling Units x 1,600 Btuh = 1,6001 Infiltration: 064 x 124 x 48 x = 11901 Air Sensible CFM ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,640 Latent Gain Btu/hr Occu ants 0 Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 X 1.24 x 41.48 X 0.00010 = 24 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 824 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 40 of 47 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 14/10/2009 Room Information Desi n Conditions Room Name: Master Suite Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,434 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72'FOutdoor Daily Range: 340F opaque surraces R-20 Roof R-20 Wall Orientation Area x X X X X x x x x x X X U -Factor X X X X X x x X X X X X CLTD 1 = = = = = = = = = Btu/hr N 1,432.9 0.0522 56.0 4,187 N 167.4 0.0740 23.0 285 E 686.6 0.0740 33.0 1,677 S 32.0 0.0740 26.0 62 W 210.0 0.0740 33.0 513 28.3X 17.6= E 3.0 17.6 7.0 34.8 E 1.7X 20.6+ 65.8X 41.4= E 11.8X 22.8+ 54.1X 48.3= E 3.0X 17.6+ 7.0X 34. Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 26 Page Total I 6.7231 Orientation Shaded Area X X:::::] X GLF + + + Unshaded Area X X X Page GLF _ = _ = (Sky) 0.0X 36.7+ 0.5x 127.4= (Sky) 0.0X 36.7+ 0.5X 127.4 N 0.0x 20.2+ 60.0X 20.2= N 0.0x 17.6+ 28.3X 17.6= N 0.0X 17.6+ 28.3X 17.6= E 3.0 17.6 7.0 34.8 E 1.7X 20.6+ 65.8X 41.4= E 11.8X 22.8+ 54.1X 48.3= E 3.0X 17.6+ 7.0X 34. Total Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants x 230 Btuh/occ. = 920 E ui ment Dwelling Units X 1 600 Btuh = 1,6001 Infiltration: 06 X 124 x 24.78 X 1309 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,124 Latent Gain Occu ants ® Occupants X 1 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4 771 x 1.24 X 24.78 X 0.00010 = 14 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 814 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 41 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 4/10/2009 Room Information Desi n Conditions Room Name: Down Stairs Outdoor Dry Bulb Temperature: 1120F Floor Area: 328 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Surfaces Wall Wall J Door Orientation Area N N 345.0 238.0 E 238.0 S 190.0 S 24.0 x 214.0 W) 24.0 0.5000 X x 0.0740 X x 0.5000 x x Infiltration: 4771 X 1.24 X 5.67 X Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration U -Factor x 0.0510 X x 0.0740 X x 0.0740 X x 0.0740 X x 0.5000 X x 0.0740 X x 0.5000 x x Infiltration: 4771 X 1.24 X 5.67 X x X X X X X X X X CLTD 1 56.0 23.0 33.0 26.0 26.0 33.0 33.0 Page Total Btu/hr Shaded Unshaded Orientation Area GLF Area GLF Btu/hr S 0.0 X 20.2 + 24.0 x 20.2 = 486 X + X X + X = X + X X + X X + X X + X X + X = X + X = X + X X + X = Page Total ass Internal Gain Btu/hr Occu ants 4 EA Occupants X 230 Btuh/occ. = 920 E ui ment Dwelling Units x 1 600 Btuh = 1,6001 Infiltration: os X X 56 X = 299 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,873 Latent Gain Btu/hr Occupants F4 Occupants X 200 Btuh/oCC. = 800 Infiltration: 4771 X 1.24 X 5.67 X Air Latent CFM ELA &W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 803 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 42 of 47 G a ). RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 14/10/2009 Room Information Desicin Conditions Room Name: Living/Family/Dining Outdoor Dry Bulb Temperature: 1120F Floor Area: 4,303 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr Wall Wall Wall Wall Wall Wall Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration M N 3 18 12 10 19 5 2 A Nage I otal Orientation 345.0 X X X X X X X X X X x X 0.0480 X X X X X X X X X X X X 19.0 = = = = = = = = = = = NE 200.0 0.0740 29.0 SE 113.0 0.0740 31.0 N 4,303.0 0.0522 56.0 N 60.0 0.0740 23.0 E 337.2 0.0740 33.0 (S) 293.0 0.0740 26.0 (SW) 163.0 0.0740 31.0 W 444.7 0.0740 33.0 48.3= S 7.0X 22.8+ 0.0x 22.9= S 0.0 22.8 32.8 22.9 S Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration M N 3 18 12 10 19 5 2 A Nage I otal Orientation Shaded Area x X x x GLF + + + + Unshaded Area X X X X Page GLF = = = _ = NE 0.0x 20.6+ 100.0x 31.8= N 0.0 20.6 240.0 20.6 E 0.0x 17.6+ 45.0X 34.8= E 0.0x 22.8+ 7.0X 48.3= E 0.0 22.8 32.8 48.3 E 6.0X 22.8+ 22.0X 48.3= S 7.0X 22.8+ 0.0x 22.9= S 0.0 22.8 32.8 22.9 S 39.2X 22.8+ 0.0x 22. S 60.Ox 20.2+O.Ox Total 315 429 259 12,572 102 823 564 374 1,086 16,5241 Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/occ. = 920 E ui ment FDwelling Units X 1 600 Btuh F 1,600 Infiltration: 06 X 24 X 4 3 X 1 3,9271 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,9181 Latent Gain Btu/hr Occu ants 0 Occupants x I Btuh/OCC. = 800 Infiltration: 4 771 x 1.24 x 74.36 x 0.00010 = 42 Air Latent CFM ELA &W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 842 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 43 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY :1 Project Title Date Della Penta Residence 14/10/2009 Room Information Desicin Conditions Room Name: Living/Family/Dining Outdoor Dry Bulb Temperature: 1120F Floor Area: 4,303 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F ue burtaces Orientation Area U -Factor CLTD 1 NW 404.0 X 0.0740 X 30.2 x x X x X x x X x x X X X x X X x x X x x x Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 1 11 F 16 G 13 17 4 20 24 Internal Gain Occu ants B4 E ui ment 1 Nage I otal Orientation Shaded Area X X X X x x x GLF + + + + + + + Unshaded Area X X x X X x 1 X GLF S 39.2 22.8 0.0 22.9 S 0.0 22.8 32.8 22.9 S 24.0 20.2 0.0 20.2 S 7.0X 22.8+ 0.0x 22.9 S 40.0 20.2 0.0 20.2 0.0x 17.6+ 45.0X 34.8 6.2X 22.8+ 0.8X 48.3 W 0.0 22.8 32.8 48.3 3.0x 22.8+ 4.0X 48. W 0.0 17.6 13.51 34.8 Page Total Btu/hr 904 904 Btu/hr Btu/hr Occupants x 230 Btuh/oCC. = 920 Dwelling Units X 1,600l Btuh 1 1,6001 Infiltration: os x 2a x 7a.3 x 1 3.92A Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,9181 Latent Gain Btu/hr Occu ants 0 Occupants x 200 Btuh/oCC. = 800 Infiltration: a 771 x 1.24 X 74.36 X 0.00010 = 42 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 842 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 44 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 14/10/2009 Room Information Desi n Conditions Room Name: Living/Family/Dining Outdoor Dry Bulb Temperature: 1120F Floor Area: 4,303 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F opaque jurraces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occu ants E ui ment 1 Page Total Orientation x x x x x x x x x x x x X X X X X X X x x x x x x x x x x x x x x + + + + + + + + + Unshaded Area X x X x x X X X X Page GLF = = = = NW 0.0x 20.2+ 24.0x 31.7= NW 0.0 17.6 35.0 26.9 NW 0.0X 20.6+ 200.0X 31.8= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occu ants E ui ment 1 Page Total Orientation Shaded Area X X X X X X X x x GLF + + + + + + + + + Unshaded Area X x X x x X X X X Page GLF = = = = NW 0.0x 20.2+ 24.0x 31.7= NW 0.0 17.6 35.0 26.9 NW 0.0X 20.6+ 200.0X 31.8= Total Occupants X 230 Btuh/occ. _ Dwelling Units x 1,60011 Btuh = Btu/hr Btu/hr 762 941 6,369 8 071 Btu/hr 920 1,6001 Infiltration: os x x 7 3s x = 27 Air Sensible CFM ELA 4ST TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,9181 Latent Gain Occu ants 0 Occupants X 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4 771 X 1.24 x 74.36 X 0.00010 = 42 Air Latent CFM ELA p W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 842 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 45 of 47 r a 1 ? RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 4/10/2009 Room Information Desi n Conditions Room Name: Guest Bedroom 1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 390 sf Outdoor Web Bulb Temperature: 73oF Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F ue Surraces Orientation Area X X X X X x x X X x x x U -Factor X X X X X x x x x x X X CLTD 1 c c = = = = = = = = = N 390.0 0.0522 77.0 N 10.0 0.0740 31.0 S 95.0 0.0740 38.0 64.2= 252.0 0.0740 55.0 5.0X 64.2 3.0 21.1 5.0 64.2 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants E ui ment FJ Nage I otal Orientation Shaded Area x x X X x x X x GLF + + + + + + + + Unshaded Area x x x x x x x X Page GLF = = = = = = = = S 48.0x 24.6+ 0.0x 32.5= W 3.0X 21.1+ 5.0X 64.2= 3.0X 21.1+ 5.0X 64.2 3.0 21.1 5.0 64.2 Total Occupants x 230 Btuh/occ. _ Dwelling Units x 1,200l Btuh = Btu/hr 1,567 23 267 1,026 2 882 Btu/hr 1.181 384 384 384 2 335 Btu/hr 920 1 200 Infiltration: 0 4 x 1.2 x 6 74 x 40 = 356 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,693 Latent Gain Occupants Occupants x 200 Btuh/occ. _ Btu/hr 800 Infiltration: a 771 x 1.2a x s.7a x 0.00010 = Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 804 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 46 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Della Penta Residence 14/10/2009 Room Information Desi n Conditions Room Name: Guest Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,096 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-20 Wall N 1,096.0 x X X X X X X X X x XF--1 X 0.0522 X X X X X X X X X x X X 56.0 = = = = = = = = = N 150.0 0.0740 23.0 E 386.0 0.0740 33.0 S 364.0 0.0740 26.0 34.8= 337.4 0.0740 33.0 17.5 34.8 S 7.0X 22.8+ 0.0x 22.9= S 7.0 22.8 0.0 22.9 2.3X 17.6+ 3.0X 34.8= W 2.3 17.6 3.0 34.8 20.5X 22.8+ 12.0X 48.3= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 31 32 33 34 35 6 7 8 9 B Nage I otai Orientation Btu/hr Shaded Area X X X X x GLF + + + + + Unshaded Area X x X X X Page GLF = = = _ = E 9.0x 17.6+ 21.0x 34.8= E 18.6X 17.6+ 23.4x 34.8= E 7.5 17.6 17.5 34.8 S 7.0X 22.8+ 0.0x 22.9= S 7.0 22.8 0.0 22.9 2.3X 17.6+ 3.0X 34.8= W 2.3 17.6 3.0 34.8 20.5X 22.8+ 12.0X 48.3= 20.5 22.8 12.0 48. 37.8X 20.2+ 22.2X 41.5= Total 3,202 255 943 700 824 5 924 Btu/hr Internal Gain Btu/hr Occu ants FJ Occupants _ X 230 Btuh/occ. 920 E ui ment Dwelling Units X 1 600 Btuh _ 1 600 Infiltration: x 1 24 x 8 9 x 1,0nn Air Sensible CFM ELA Z�ST TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,6001 Latent Gain 7771­7Btu/hr Occu ants Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 X 1.24 X 18.94 x 0.00010 = 11 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 811 EnergyPro 4.4 by EnergySoft User Number: 5862 Job Number: Page: 47 0f 47