Loading...
04-3356 (AR) Title 24Al i TITLE 24 Energy Conservation Standards Compliance Report BAGGS RESIDENCE ADIDITION 78-705 DESCANSO LANE LA QUINTA / December 12, 2003 • Job Number: 24005A Prepared For. - MR. AND MRS. RALPH BAGGS 78-705 DESCANSO LANE LA QUINTA, CA 92253 r.ITY OF LA QUINTA • 760-771-1271 BUILDING & SAFETY DEPT, APPROVED FOR CONSZM- I DATF_,,,4[!4,,, dlin's enterprises vvvvvvv Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 v Palm Springs, CA 92263 760-322-5004 / 323-3644 (fax) E-mail: CMadlin@aol.com V-) Madlin s enterpfises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (lax) ....... Title 24 Energy Conservation Standards Compliance Report This proposed project has been reviewed for compliance with the 2001 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with the standards as outlined in the attached compliance forms and documentation. Date: December 12, 2003 Job Number: 24005A Prepared For: MR. AND MRS. RALPH BAGGS Owner's Name: RALPH AND SALLY JO BAGGS Project Name: BAGGS RESIDENCE ADDITION Project Location: 78-705 DESCANSO LANE - LA QUINTA Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM Certified Energy Analyst Catherine M. Madlin NR 98-90-544 r r R 98.90-144 rr rCABEC CcGfornio Association of Building Energy Consultants v Post Office Box 1443 v Palm Springs, Ca 92263 v i� Madlin's enteipmes Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 l 323-3644 vvvvvvv ................ . ............ ............. ........ .... ... ......... ........... %. ............ ............ MIN NGE IJIREMENT$ . .... Job Name BAGGS RESIDENCE ADDITION Job No. / File No. 24005A Method of Compliance Micropas V6.1 Computer Simulation Existing + Addition Calculation Total Conditioned Square Footage 113 Sq. Ft. Addition Roof Radiant Barrier Not Required Insulation: Roof / Ceiling R-38 Batts Insulation: Walls R-19 Batts - Addition and Fill-in Exterior Walls Insulation: Floor - Slab on Grade Not Required Insulation: H.V.A.C. Ducts/ Location/Testing New Ducts Only: R-4.2 / Attic No Duct Testing Glazing U Value / Type: Operable, Fixed, French Dr. 0.45, Dual Pane, Low E2 (NFRC Tested Value) Glazing: Solar Heat Gain Coefficient (Uncoated) 0.45 Operable, Fixed,- French Doors Glazing: Exterior Shading Not Required Thermal Mass Square Footage & % Not Required H.V.A.C. System Type Existing Equipment Domestic Hot Water Heater Existing Water Heater Other Requirements Applicable Mandatory Measures • Post Office Box 1443 v Palm Springs, Ca 92263 v Madlin s enterpfises Catherine M. Madlin, Certified Energy Analyst e 760-322-5004 / 323-3644 "az) Title 24 Compliance Foams CERTIFICATE OF COMPLIANCE: RESIDENTIAL ----------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Project Address........ 78-705 DESCANSO LANE Or RANCHO LA QUINTA Documentation Author... CATHERINE M. MADLIN Madlin's Enterprises P.O. Box 1443 Palm Springs, CA 92262 Page 1 CF -1R Date..12/12/03 12:35:36 ******* --------------------- *v6.01 ******* I Building Permit Plan C ec Date 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 2946 sf Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.. ...... Floor Construction Type.... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Single Family Detached Existing Plus Addition Front Facing 0 deg (N) 1 1 Slab On Grade 27.5 % of floor area 0.5 Btu/hr-sf-F 0.63 10 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type ------------ Type ------- R -value -------- R -value -------- R -value U -factor Location/Comments Wall Wood R-17.8 R-0 ------- R-17.8 ------- -------------------- 0.065 Door None R-0 R-0 R-0 0.330 Roof Wood R-11 R-27 R-38 0.025 S1abEdge None R-0 R-0 None F2=0.760 Front (N) 24.0 FENESTRATION 0.700 Over - Area U- Interior Exterior hang/ Orientation - (sf) Factor SHGC Shading. Shading -------------- Fins -------------------- Window Front (N) ----- 48.0 ------ ------ 0.480 0.650 --------------- Standard Standard ----- None Window Front (N) 18.0 0.720 0.700 Standard Standard None Window Front (N) 24.0 0.720 0.700 Standard Standard None Window Left (E) 190.9 0.480 0.650 Standard Standard None Window Left (E) 19.0 0.720 0.700 Standard Standard None Window Left (E) 18.8 0.480 0.650 Standard Standard None Window Back (S) 48.0 0.480 0.650 Standard Standard None Window Back (S) 141.4 0.480 0.650 Standard Standard None Window Back (S) 18.8 0.480 0.650 Standard Standard None Window Right (W) 166.9 0.480 0.650 Standard Standard None Window Right (W) 1.0 0.720 0.700 Standard Standard None Skylight Horz 4.5 0.800 0.730 None None None 'Window Left (E) 25.0 0.450 0.450 Standard Standard None Door Left (E) 24.0 0.450 0.450 Standard Standard None Window Back (S) 7.5 0.450 0.450 Standard Standard None G Door Back (S) 48.0 0.450 0.450 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R ------------------------------------------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- •I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM CF -1R l User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- FENESTRATION The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The HVAC equipment is existing. The night setback thermostat. The water heater is existing. Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window Back (S) ----- ------ --------------------- 7.5 0.450 0.450 Standard -------------- Standard ----- None SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 2833 Standard Slab 113 ! HVAC SYSTEMS ------------ Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat • Type Efficiency Airflow Location R -value Leakage D Type ------------------------ Furnace 0.780 ------------------------- AFUE n/a Attic R-4.2 ------- ------ No No ---------- Setback . ACSplit 12.00 SEER No Attic R-4.2 No No Setback Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSplit 12.00 SEER No Attic R-4.2 No No Setback REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The HVAC equipment is existing. The night setback thermostat. The water heater is existing. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... BAGGS.ESTANCIA.3201 -------------------------------------------------- -------------------------------------------------- 'I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 User#-MP0207 User-Madlin's Enterprises REMARKS COMPLIANCE STATEMENT Page 3 CF -1R' Date..12/12/03 12:35:36 ------------------------ ------------------------ Program-FORM CF -1R Run--EXI STING+ADD -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied 116116indicated in the Special Features. Modeling Assumptions section.s►j DESIGNER or OWNERrN... DOCUMENTATION AUTHOR Name.... RALPH BAGGS CATHERINE M. MADLIN Company. OWNER ny. Madlin's Enterprises Address. 78-705 DESCANSO LANE ss. P.O. Box 1443 LA QUINTA, CA 92253 Palm Springs, CA 92262 Phone... 760-7 1271 Phone... 760-322-5004 License. Signed.. J a3 Signed.. (date) (date) ENFORCEMENT AGENCY iZ-!Z•o3 Name.... Certified Energy AnaIyat Title... Agency.. Catherine M. Maddfln NR 98-90.544 r r Phone... r r R 98-90-144 Signed.. C A 4 E i —(date) ) Coiifornio Association of Wkkrg MANDATORY MEASURES CHECKLIST: RESIDENTIAL =------------------------------------------------------------------------------ Page 1 MF -1R ------------------------------------------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 Project Address........ 78-705 DESCANSO LANE ******* --------------------- RANCHO LA QUINTA _*v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... ------------------------------------------------------------------------------- MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 ----------------------------------------------------------=-------------------- User-Madlin's Enterprises Run-EXISTING+ADD Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents,the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE.MEASURES -------------------------- i .i i *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R -Value. .j *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply i to exterior mass walls). Design-.Enforce- er ✓. ment NA *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater f than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. j 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned I spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. i 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: 'a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. j V/ ^4 NA —4 NA MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R =----------------------------------------------------------------=------------- ------------------------------------------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. EKMII 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ✓ 150(1): Setback thermostat on all applicable heating and/or cooling systems. EXE 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings.shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually ✓ operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12.35.36 • I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM MF -1R I User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD -----------------------=------------------------------------------------------- pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). AIA 4 LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled bya switch on a readily accessible lighting control panel at an entrance to the kitchen. /VA 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with.lamps with an efficacy of 40 lumens/watt or greater switched at -the entrance to the room or one of the alternatives to this requirement allowed in Seca 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. Madlin -s enterprises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ... . v .Remodeled Building 4 ADDITION WORKSHEET Page 1 ADD Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 Project Address........ 78-705 DESCANSO LANE ******* --------------------- • RANCHO LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443• Plan C ec Date f Palm Springs, CA 92262 760-322-5004 Fie C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 x6.01 by Enercomp; Inc. MICROPAS6 v6.01 File -24005A1 Program -ADDITIONS User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD I------------------------------------------------------------------------------- ADDITION/ALTERATION WORKSHEET - COMPUTER PERFORMANCE -------------------------=-------------------------- EXISTING File Name. ..... ....... 24005A1 - EXISTING HOUSE Conditioned Floor Area..... 2833 sf Standard Design Energy Use. 39.96 kBtu/sf-yr Proposed Design Energy Use. 78.40 kBtu/sf-yr NEW (EXISTING PLUS ADDITION/ALTERATION) File Name.. .. ........ 24005EA - EXISTING+ADD Conditioned Floor Area..... 2946 sf Standard Design Energy Use. 39.31 kBtu/sf-yr Proposed Design Energy Use. 75.88 kBtu/sf-yr FLOOR AREA RATIO Floor Existing New Area Floor Area Floor Area Ratio ---------- ------------- -------- 2833 / 2946 0.962 DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION/ALTERATION) Floor Addition/ New Area Existing Existing Alteration Standard Ratio Proposed Standard Design ----------------------- 39.31. + 0.962 x ( 78.40 - 39.96) = 76.28 Note: If (Existing Proposed - Existing Standard) is negative, this difference is set to zero. ---------------- ----------------------------------------------------- ADDITION/ALTERATION ENERGY USE SUMMARY = _-------------------------------------- _ Addition/ _ Energy Use Alteration Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = - New .................... 76.28 75.88 0.40 = *** Addition/Alteration complies with Computer Performance --------------------------------------------------------------------------- --------------------------------------------------------------------------- COMPUTER METHOD SUMMARY Page 1 C -2R Projec t Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 Project Address........ 78-705 DESCANSO LANE ******* --------------------- • RANCHO LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone............ 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance _ (kBtu/sf=yr) Design Design Margin = Space Heating.......... 3.48 2.24 1.24 = = Space Cooling.......... 35.83 73.64 -37.81 = = -------- Total 39.31 -------- 75.88 -------- _ -36.57 _ *** Water Heating not calculated GENERAL INFORMATION ------------------- Conditioned Floor Area..... 2946 sf Building Type .............. Single Family Detached Construction Type ......... Existing Plus Addition Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Building Stories. 1 { Weather Data Type.......... FullYear Zone Type ---------- 1.ZONE .Residence 2.ZONE Residence Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 2 29460 cf 2946 sf 27.5 % of floor area 0.5 Btu/hr-sf-F 0.63 10 ft BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage (sf) (Cf) Units itioned Type (ft) (sf) Credit ------------ ----------------------- ----- -------- --------- 2833 28330 0.96 Yes Setback 2.0 Standard No 113 1130 0.04 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C-2R -- -- ---------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 ----------------- ---------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program-FORM C-2R User#-MPO207 User-Madlin's Enterprises Run-EXISTING+ADD i ------------------------------------------------------------------------------- PERIMETER LOSSES Form 3 Location/ Reference Comments --------------------------- W.19.2X6.16 W.19.2X6.16 W.19.2X6.16 W.19.2X6.16 None R.38.2X4.24 W.19.2X6.16 W.19.2X6.16 R.38.2X4.24 Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1.ZONE - Existing 10 SlabEdge 247 0.760 R-0 No 2.ZONE - New 11 SlabEdge 22 0.760 R-0 No FENESTRATION SURFACES OPAQUE SURFACES Act Area U- --------------- Insul Act Solar Surface (sf) factor R-val Azm Tilt Gains -------------- 1.ZONE - ------ Existing ----- ----- --- ---- ----- 1 Wall 400 0.065 17.8 0 90 Yes 2 Wall 487 0.065 17.8 90 90 Yes 4 Wall 177 0.065 17.8 180 90 Yes 6 Wall 663 0.065 17.8 270 90 Yes 7 Door 20 0.330 0 0 90 Yes 8 Roof 2829 0.025 38 n/a 0 Yes 2.ZONE - New 19.0 0.720 0.700 90 90 3 Wall 66 0.065 17.8 90 90 Yes 5 Wall 62 0.065 17.8 180 90 Yes 9 Roof 113 0.025 38 n/a 0 Yes PERIMETER LOSSES Form 3 Location/ Reference Comments --------------------------- W.19.2X6.16 W.19.2X6.16 W.19.2X6.16 W.19.2X6.16 None R.38.2X4.24 W.19.2X6.16 W.19.2X6.16 R.38.2X4.24 Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1.ZONE - Existing 10 SlabEdge 247 0.760 R-0 No 2.ZONE - New 11 SlabEdge 22 0.760 R-0 No FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- 1.ZONE - Existing ----- ----- ----- --- ---- -------------- -------------- 1 Window Front (N) 48.0 0.480 0.650 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 18.0 0.720 0.700 0 90 Standard/0.76 Standard/0.68 3 Window Front (N) 24.0 0.720 0.700 0 90 Standard/0.76 Standard/0.68 4 Window Left (E) 190.9 0.480 0.650 90 90 Standard/0.76 Standard/0.68 5 Window Left (E) 19.0 0.720 0.700 90 90 Standard/0.76 Standard/0.68 6 Window Left (E) 18.8 0.480 0.650 90 90 Standard/0.76 Standard/0.68 7 Window Back (S) 48.0 0.480 0.650 180 90 Standard/0.76 Standard/0.68 8 Window Back (S) 141.4 0.480 0.650 180 90 Standard/0.76 Standard/0.68 9 Window Back (S) 18.8 0.480 0.650 180 90 Standard/0.76 Standard/0.68 10 Window Right (W) 166.9 0.480 0.650 270' 90 Standard/0.76' Standard/0.68 11 Window Right (W) 1.0 0.720 0.700 270 90 Standard/0.76 Standard/0.68 12 Skylight Horz 4.5 0.800 0.730 0 0 None/1 None/1 1.ZONE - New 13 Window Left (E) 25.0 0.450 0.450 90 90 Standard/0.76 Standard/0.68 2.ZONE - New 14 Door Left (E) 24.0 0.450 0.450 90 90 Standard/0.76 Standard/0.68 15 Window Back (S) 7.5 0.450 0.450 180 90 Standard/0.76 Standard/0.68 16 Door Back (S) 48.0 0.450 0.450 180 90 Standard/0.76 Standard/0.68 417 Window Back (S) 7.5 0.450 0.450 180 90 Standard/0.76 Standard/0.68 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12.35.36 --------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM C -2R I User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- SLAB SURFACES Area Slab Type (sf) ---------------- ------ 1.ZONE Standard Slab 2833 2.ZONE Standard Slab 113 HVAC SYSTEMS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only—The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The HVAC equipment is existing. The night setback thermostat. The eater heater is existing. Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R -value Leakage D Eff 1'. ZONE Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.596 2.ZONE Furnace 0.780 AFUE n/a Attic R=4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.596 REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only—The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The HVAC equipment is existing. The night setback thermostat. The eater heater is existing. CONSTRUCTION ASSEMBLY Page 1 3R -----------------------------------------------=-----------=------------------- ------------------------------------------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 ------------------=--=--------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM 3R User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- Parallel Path Method Reference Name . W.19.2X6.16 Description .... Wall R-19 2x6 16oc Type Wall R -Value ........ 17.8 Hr-sf-F/Btu Framing ' Material ..... FIR.2X6 Type .... Wood Description .. 2x6 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Total R -Value: ';r 1 / 0.065 = 15.28 hr-sf-F/Btu Material Cavity Frame Name Description R -Value R-Value 0. ------------- FILM.EX ---------------------------------------- Exterior air film: winter value --------- 0.17 --------- 0.17 1. STUCCO.0.88 0.875 in stucco 0.17 0.17 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R19 R-19 batt insul (cavity = 5.5 in) 17.80 -- 3f. FIR.2X6 2x6 fir -- 5.45 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values --------- 19.34 --------- 6.98 FRAMING ADJUSTMENT CALCULATION Cavity, Framing Total U -Factor: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-F Total R -Value: ';r 1 / 0.065 = 15.28 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 2 3R Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36 --------------------------------------------------------- • I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM 3R User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- --------------------------------- Parallel Path Method Reference Name . R.38.2X4.24 Description .... Roof R-38 2x4 24oc Type ........... Roof R -Value ........ 38 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type .... Wood Description .. 2x4 fir Spacing .... 24 inches on center Framing Frac.. 0.07 --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ---------------- U-Factor: (1 1 41.15 x 0.93) + (1 1 33.62 x 0.07) 0:025 Btu/hr-sf-F Total R -Value: 1 / 0.025 = 40.51 hr-sf-F/Btu Material. Cavity Frame Name Description R -Value R-Value 0. ------------- FILM.EX ---------------------------------------- Exterior air film: winter value --------- 0.17 --------- 0.17 1. SHNGL.ASPHLT Asphalt shingle roofing 0.44 0.44 2. BLDG.PAPER Building paper.(felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5. BATT.R27.0 R-27 batt insulation 27.00 27.00 6c. BATT.RII.0 R-11 batt insul (cavity > 3.5 in) 11.00 -- 6f. FIR.2X4 2x4 fir -- 3.46 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R -Values --------- 41.15 --------- 33.62 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ---------------- U-Factor: (1 1 41.15 x 0.93) + (1 1 33.62 x 0.07) 0:025 Btu/hr-sf-F Total R -Value: 1 / 0.025 = 40.51 hr-sf-F/Btu Madlin's enterprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) ....... Existing Building COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:36:42 Project Address........ 78-705 DESCANSO LANE ******* --------------------- • RANCHO LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File -24005A1 Wth-CTZ15S92 Program -FORM C -2R i User#-MP0207. User-Madlin's Enterprises Run -EXISTING HOUSE -----------------------------------------=------------------------------------- -- ----------------------------- = MICROPAS6 ENERGY USE SUMMARY = ---------------------------- Energy Use Standard Proposed Compliance = (kBtu/sf-yr) Design Design Margin = _----------------------------------------------------- _ = Space Heating.......... 3.58 2.19 1.39 = = Space Cooling.......... 36.38 76.21 -39.83 = Total 39.96 78.40 -38.44 = Water Heating not calculated GENERAL INFORMATION ------------------- Conditioned Floor Area..... 2833 sf Building Type .............. Single Family Detached Construction Type ....... Existing Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear i i Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area.......:. Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 28330 cf 2833 sf 27.5 % of floor area 0.5 Btu/hr-sf-F 0.65 10 ft BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) -------------- -------- ---- Units itioned Type ----- (ft) (sf) Credit 1.ZONE ------------------ ------------- --------- Residence 2833 28330 1.00 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12.36.42 ------------------------------------------------------------------------------- • I MICROPAS6 v6.01 File -24005A1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -EXISTING HOUSE ` ------------------------------------------------------------------------------- OPAQUE SURFACES PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- -.ZONE - Existing 7 S1abEdge 268 0.760 R-0 No FENESTRATION SURFACES ! Area U- Insul Act U- Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- 1.ZONE - ------ Existing ----- ----- --- ---- ----- ------------ ---------------- 1 Wall 400 0.065 17.8 0 90 Yes W.19.2X6.16 2 Wall 577 0.065 17.8 90 90 Yes W.19.2X6.16 3 Wall 248 0.065 17.8 180 90 Yes W.19.2X6.16 4 Wall 663 0.065 17.8 270 90 Yes W.19.2X6.16 5 Door 20 0.330 0 0 90 Yes None 6 Roof 2829 0.025 38 n/a 0 Yes R.38.2X4.24 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- -.ZONE - Existing 7 S1abEdge 268 0.760 R-0 No FENESTRATION SURFACES ! Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- 1.ZONE - Existing ----- ----- ----- --- ---- -------------- -------------- 1 Window Front (N) 48.0 0.480 0.650 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 18.0 0.720 0.700 0 90 Standard/0.76 Standard/0.68 3 Window Front (N) 24.0 0.720 0.700 0 90 Standard/0.76 Standard/0.68 4 Window Left (E) 215.9 0.480 0.650 90 90 Standard/0.76 Standard/0.68 5 Window Left (E) 19.0 0.720 0.700 90 90 Standard/0.76 Standard/0.68 6 Window Left (E) 18.8 0.480 0.650 90 90 Standard/0.76 Standard/0.68 7 Window Back (S) 48.0 0.480 0.650 180 90 Standard/0.76 Standard/0.68 8 Window Back (S) 195.40.480 0.650 180 90 Standard/0.76 Standard/0.68 9 Window Back (S) 18.8 0.480 0.650 180 90 Standard/0.76 Standard/0.68 10 Window Right (W) 166.9 0.480 0.650 270 90 Standard/0.76 Standard/0.68 11 Window Right (W) 1.0 0.720 0.700 270 90 Standard/0.76 Standard/0.68 12 Skylight Horz 4.5 0.800 0.730 0 0 None/1 None/1 I SLAB SURFACES ------------- Area Slab Type ---------------- (sf) 1.ZONE ------ Standard Slab 2833 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:36:42 ---------------------------------------- MICROPAS6 v6.01 -File-24005A1 Wth-CTZ15S92 Program -FORM C -2R --------7---------------------------------------------------------------------- User#-MP0207 User-Madlin's Enterprises Run -EXISTING HOUSE HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R -value Leakage D Eff ------------- 1.ZONE -------------------------------------- ----------------- ---- Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.596 REMARKS The values and materials used in this existing house Micropas run was obtained from the original house CF -1R issued on 9/10/93. A copy of this document is included in the addendums and notes section of this report. Madlin -s enterprises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ®®®®v vv H. V.A. C. Load Calculation HVAC SIZING Page 1 HVAC ------------------------------------------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:42:56 Project Address........ 78-705 DESCANSO LANE ******* --------------------- RANCHO LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date. Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone. ..... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. --------- -------------------------------------------------------------- f MICROPAS6 v6.01 File-24005EA Program -HVAC SIZING I User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 2946 sf Volume.. ............ 29460 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ PALM DESERT Latitude... .... ... .. 33.7 degrees Winter Outside Design ....... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ...... 34 F Interior Shading Used No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 15393 ----------- 8022 Glazing Conduction ............... 15291 13681 Glazing Solar .................... n/a 32374 Infiltration ..................... 15556 10295 Internal Gain .................... n/a 2532 Ducts. .................... 4624 6690 Sensible Load .................... 50863 73594 Latent Load ...................... n/a 14719 Minimum Total Load 50863 88313 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements,. outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC ------------------------------------------------------------------------------- Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:42:56 -------------------------------------------------------- MICROPAS6 v6.01 File-24005EA Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD ------------------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ----------------------- =---------------- ZONE '1.ZONE' Floor Area ....................... 2833 sf Volume ........................... 28330 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 14333 ----------- 7601 Glazing Conduction ............... . 13803 12350 Glazing Solar....... ........... n/a 30352 Infiltration ..................... 14960 9900 Internal Gain...... ............ n/a 2448 Ducts ............................ 4310 6265 Sensible Load .................... 47405 68916 Latent Load...................... n/a 13783 Minimum Zone Load ----------- 47405 ----------- 82699 ZONE 12.ZONE' Floor Area ....................... 113 sf Volume ........................... 1130 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction.and Solar...... ----------- 1060 ----------- 421 Glazing Conduction ............... 1488 1331 Glazing Solar .................... n/a 2022 Infiltration ..................... 597 395 InternalGain .................... n/a 84 Ducts ............................ 314 425 Sensible Load .................... 3459 4678 Latent Load ...................... n/a 936 Minimum Zone Load ----------- 3459 ----------- 5614 Madlin's enterprises Catherine M. Madlin, Certified EnergyAnalyst • 760-322-5004 / 323-3644 (fax) ®®®®®v Addendums and Notes I + 64" -5 ` , Ad i NE -i505? XATCH !L'.'4.cT G. A46 JR - I' A ryp.! rci.11 Tez r7 HALLO TG LC + �I A -, DEN All� OF 3080 �zvi r I_F4I1N6H BOORS AITH r ri- NkElPi F4AL 5 �c (113 50. FT.) F '15TNC, !EOUAL LXAL .... -- --- —• - i __; ._ .. — __ ....._ _._.... ��-...._ .'•--' - -F3n:V`1�7i - j + F.r -0 PARTIAL FLOOR PLAN (113SOFrs I -A In C' E, ryINDnWFILL 1: 'XlST1NG AREA OF ADDITION NU'iM r4AI11 5 TO MATCH Ei<!5TINr, I + 64" -5 ` , Ad i NE -i505? XATCH !L'.'4.cT G. A46 JR - I' A ryp.! rci.11 Tez r7 HALLO TG LC + �I A -, DEN All� OF 3080 �zvi r I_F4I1N6H BOORS AITH r ri- NkElPi F4AL 5 �c (113 50. FT.) F '15TNC, !EOUAL LXAL .... -- --- —• - i __; ._ .. — __ ....._ _._.... ��-...._ .'•--' - -F3n:V`1�7i - j + F.r -0 PARTIAL FLOOR PLAN (113SOFrs I -A In C' i2 • �•rh, PAGE 02 12- 11-o3 t CBRTIFICAS9 OF Ci>64?LIANCE: Residential (pert 1 of 2) CF -1R paga, 3 or 13 Project Nam e: The Orchard (Entancia 3201) pat®: 9/10/&993 Address: = Lai Quinta, CaliforniaBuIlding Ti—rTail-R-a- Designer: Robert taab Haxt ry J,'a - Documentation: ,aber3 Dodd Associates 1COMPLY 24 User 1000 CFNERAL INp"RKATION Ccmplianca Method: COMPLY 24 version 4, 11 -� y Climate Zone: is Conditioned Floor Area: 2831 @aft. Buildinq Types Single !aa Cast r. Buildinq Front orientation: Four Cardinal Orientations Number of Dwalling Units: 1 Floor Construction Type: Slab on Grade �. AUILDING SHPI.L INSULATION Ccsnporaeent 0-Ytloagi Location/Coaments R-19 Wall (90.19.2x5.16) -0.065 esstarci.a 3201 --P_._____-_______..__ R-'38 Roof(R.a8.2x14..16) 0.026 Estancia 3201 Slab Perimeter v/R-0.0 0.720 Estancia 3201 FENFST ATION Shads-nq Devices Frame! Orient, Area U -9a1 Type -- --48.9 Interior F.xkarior OH 5P Type Front- 0,48 Doubles Std DrapeStandard' Bitq-Ser 1Y N Vinyl Front 1.8.0 0.77 Douhlo Std Drape Standard Bug Scr Y N Done 3roeit 24.0 0.73 Doublm Std Drape 5tandaird Dug Scr Y N Voila Lsrt 215.4 0.48 Double Std Drape Standards Bug Scr x N Vinyl Lea rt 19.0 0.72 Double Std Drape Standard Bug Sar Y N Atone �^ 14 ft 18.8 0.46 Double Std Drape Standard Bug Scr X X Vinyl Beck 48.0 0.44 Daubi® S�.d Drape Standard Bug Scr y R V.lnyl Back 195.4 0.46 Doubler 9 Drape Standard Bug Scr. Y N Vinyl Back 18.6 0.48 Double Drape Standard Bug Scr Y N Vinyl Right 166.9 0.49 Double S Drape Standard Bug Scr Y N Vinyl Right 1.0 0.72 Double Std Drapa Standard Bug Scr Y 9 None Skylight 4.3 0.80 wuhlo none node N N Metal - THE1t!l.4.i. MASS Area Thirk Type .._...--------------Crna-ri.r4q (a!)- (in)- Lavation/De4aCripCiotl Concrete, Heavyweight Cw4*rsd _-----. 3939 3.50 Slab an Gmde _ Frame Wall, Gyp. Board_ Exposed 4949 0.63 Lstancis 3201/Int Raps Masonry, Solidi Crout Expoffied 48 6.00 Estancia 3101/Int Naga CEWITICATE OF CMLIANCE: Residential (part 2 of 2) CF -1R page 4 of 13 Project ~Name: The Orchard w(SatAncia 31201)-----------�-Date- -9/10/1993-'- 1COMPLY Documentation: Gabel Dodd Associates 24 User 1000 G __------_.-_.-__�....__._.. J HVAC SYSTERS Kiniaum D10tri.b Type Duct TStat System Type Efficiency am Location Real Type Location/Comments t (Z•v��3 SpltAirCond12.100 SEAR Ducts in Actio 9.4 o+a..a.vw Nater No. 'tank Ext - WATER HEATING SY5TM3 Hestor In Margy Size Insul Syst4ata°+Name __ _---_-__-- Distribution Typm Type--- Bye Factor (gal) R_Val AIUMChN AP? GX2F9Q-754 Reaire-TA%e4T%asp Sto r0ax 1 0.53 66.4 12.0 MM WATER MUTZ. ZQUIPKZn DETAIL %Aeo Rated Stdby TarA pilot System mama System Type Eff Input Yves R -Val Light AMMUCAN APP Mr'40-754 Daa4etiCIM 0.760 5098 0.000 0.0 0 SPECIAL FFA`1YDM!VEKAM COKPLrAtZCx STATENUM This Certificat.s of Compliance lists the building features and performance s�ecitications neaded to comply with Title 24, Parts 1 6 4 of the Califor- n:.aa Code of A&;aiatiens, and the adnirti+istrative raguulationaa to iuplezcnt them. This certifir_ato has ben signed by the individual with overall design responsibility. when thin certificate of compliance is submitted Per a single, building plan to be built in multiple orlsntations, any shading. feature that is varied is indicated in the Spacial FeaYtures/Ramar" section DP.MMER or QidNM DOCUM"ATION AUTHOR (Per Business 4 Professions Cods) Kisti Rruc:ari Robert Lamb Hart Cabal Dodd Associates 243 Californias Street 761 Sir Francis Drake Blvd Smn Francisco, California San iAnselmo, CA 44960 �.— — Lir ---- - (415) 436-75as (signature)— Hate atusa ante ENFORCMt rs AGCY man*: Title •'-'"""-" Agency: Telephone: �a're� aF ash+ atej yes !: ��p•�a� at :. •oomt �t:..+a.�t • ... 2 -n C