04-3356 (AR) Title 24Al
i
TITLE 24
Energy Conservation
Standards Compliance Report
BAGGS RESIDENCE ADIDITION
78-705 DESCANSO LANE
LA QUINTA
/ December 12, 2003 • Job Number: 24005A
Prepared For. -
MR. AND MRS. RALPH BAGGS
78-705 DESCANSO LANE
LA QUINTA, CA 92253
r.ITY OF LA QUINTA • 760-771-1271
BUILDING & SAFETY DEPT,
APPROVED
FOR CONSZM-
I
DATF_,,,4[!4,,,
dlin's
enterprises
vvvvvvv
Catherine M. Madlin, Certified Energy Analyst
Post Office Box 1443 v Palm Springs, CA 92263
760-322-5004 / 323-3644 (fax)
E-mail: CMadlin@aol.com
V-) Madlin s
enterpfises
Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (lax) .......
Title 24 Energy Conservation Standards
Compliance Report
This proposed project has been reviewed for compliance with the 2001 State of California
Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design
described in this compliance portfolio is in conformance with the standards as outlined in
the attached compliance forms and documentation.
Date: December 12, 2003
Job Number: 24005A
Prepared For: MR. AND MRS. RALPH BAGGS
Owner's Name: RALPH AND SALLY JO BAGGS
Project Name: BAGGS RESIDENCE ADDITION
Project Location: 78-705 DESCANSO LANE - LA QUINTA
Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM
Certified Energy Analyst
Catherine M. Madlin
NR 98-90-544
r r R 98.90-144
rr
rCABEC
CcGfornio Association of Building Energy Consultants
v Post Office Box 1443 v Palm Springs, Ca 92263 v
i�
Madlin's
enteipmes
Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 l 323-3644
vvvvvvv
................ . ............
............. ........ .... ... .........
........... %.
............
............
MIN NGE
IJIREMENT$ . ....
Job Name
BAGGS RESIDENCE ADDITION
Job No. / File No.
24005A
Method of Compliance
Micropas V6.1 Computer Simulation
Existing + Addition Calculation
Total Conditioned Square Footage
113 Sq. Ft. Addition
Roof Radiant Barrier
Not Required
Insulation: Roof / Ceiling
R-38 Batts
Insulation: Walls
R-19 Batts - Addition and Fill-in Exterior Walls
Insulation: Floor - Slab on Grade
Not Required
Insulation: H.V.A.C. Ducts/ Location/Testing
New Ducts Only: R-4.2 / Attic
No Duct Testing
Glazing U Value / Type: Operable, Fixed, French Dr.
0.45, Dual Pane, Low E2
(NFRC Tested Value)
Glazing: Solar Heat Gain Coefficient (Uncoated)
0.45 Operable, Fixed,- French Doors
Glazing: Exterior Shading
Not Required
Thermal Mass Square Footage & %
Not Required
H.V.A.C. System Type
Existing Equipment
Domestic Hot Water Heater
Existing Water Heater
Other Requirements
Applicable Mandatory Measures
• Post Office Box 1443 v Palm Springs, Ca 92263 v
Madlin s
enterpfises
Catherine M. Madlin, Certified Energy Analyst e 760-322-5004 / 323-3644 "az)
Title 24 Compliance Foams
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
-----------------------------------------------
Project Title.......... BAGGS.ESTANCIA.3201
Project Address........ 78-705 DESCANSO LANE
Or RANCHO LA QUINTA
Documentation Author... CATHERINE M. MADLIN
Madlin's Enterprises
P.O. Box 1443
Palm Springs, CA 92262
Page 1 CF -1R
Date..12/12/03 12:35:36
******* ---------------------
*v6.01
******* I Building Permit
Plan C ec Date
760-322-5004 Field C ec Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 2946 sf
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories.. ......
Floor Construction Type....
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Single Family Detached
Existing Plus Addition
Front Facing 0 deg (N)
1
1
Slab On Grade
27.5 % of floor area
0.5 Btu/hr-sf-F
0.63
10 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing
Total
Assembly
Type
------------
Type
-------
R -value
--------
R -value
--------
R -value
U -factor Location/Comments
Wall
Wood
R-17.8
R-0
-------
R-17.8
------- --------------------
0.065
Door
None
R-0
R-0
R-0
0.330
Roof
Wood
R-11
R-27
R-38
0.025
S1abEdge
None
R-0
R-0
None
F2=0.760
Front
(N)
24.0
FENESTRATION
0.700
Over -
Area
U-
Interior
Exterior
hang/
Orientation
-
(sf)
Factor
SHGC
Shading.
Shading
--------------
Fins
--------------------
Window
Front
(N)
-----
48.0
------ ------
0.480
0.650
---------------
Standard
Standard
-----
None
Window
Front
(N)
18.0
0.720
0.700
Standard
Standard
None
Window
Front
(N)
24.0
0.720
0.700
Standard
Standard
None
Window
Left
(E)
190.9
0.480
0.650
Standard
Standard
None
Window
Left
(E)
19.0
0.720
0.700
Standard
Standard
None
Window
Left
(E)
18.8
0.480
0.650
Standard
Standard
None
Window
Back
(S)
48.0
0.480
0.650
Standard
Standard
None
Window
Back
(S)
141.4
0.480
0.650
Standard
Standard
None
Window
Back
(S)
18.8
0.480
0.650
Standard
Standard
None
Window
Right
(W)
166.9
0.480
0.650
Standard
Standard
None
Window
Right
(W)
1.0
0.720
0.700
Standard
Standard
None
Skylight
Horz
4.5
0.800
0.730
None
None
None
'Window
Left
(E)
25.0
0.450
0.450
Standard
Standard
None
Door
Left
(E)
24.0
0.450
0.450
Standard
Standard
None
Window
Back
(S)
7.5
0.450
0.450
Standard
Standard
None
G Door
Back
(S)
48.0
0.450
0.450
Standard
Standard
None
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
-------------------------------------------------------------------------------
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
•I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM CF -1R
l User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
FENESTRATION
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materials without additional compliance calculations.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
is responsible for determining the HVAC design loads and
equipment selection(s). The HVAC design shall be done in
accordance with industry standards. The load calculation in
this report considers ambient temperature loads, solar gain,
people and a fixed latent heat gain percentage. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The HVAC equipment is existing.
The night setback thermostat.
The water heater is existing.
Over -
Area U- Interior
Exterior
hang/
Orientation
(sf) Factor SHGC Shading
Shading
Fins
--------------------
Window Back
(S)
----- ------ ---------------------
7.5 0.450 0.450 Standard
--------------
Standard
-----
None
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 2833
Standard Slab 113
!
HVAC SYSTEMS
------------
Refrigerant
Tested ACCA
Equipment
Minimum Charge and Duct Duct
Duct Manual
Thermostat
• Type
Efficiency Airflow Location R -value
Leakage D
Type
------------------------
Furnace
0.780
-------------------------
AFUE n/a Attic R-4.2
------- ------
No No
----------
Setback
. ACSplit
12.00
SEER No Attic R-4.2
No No
Setback
Furnace
0.780
AFUE n/a Attic R-4.2
No No
Setback
ACSplit
12.00
SEER No Attic R-4.2
No No
Setback
REMARKS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materials without additional compliance calculations.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
is responsible for determining the HVAC design loads and
equipment selection(s). The HVAC design shall be done in
accordance with industry standards. The load calculation in
this report considers ambient temperature loads, solar gain,
people and a fixed latent heat gain percentage. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The HVAC equipment is existing.
The night setback thermostat.
The water heater is existing.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
Project Title.......... BAGGS.ESTANCIA.3201
--------------------------------------------------
--------------------------------------------------
'I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92
User#-MP0207 User-Madlin's Enterprises
REMARKS
COMPLIANCE STATEMENT
Page 3 CF -1R'
Date..12/12/03 12:35:36
------------------------
------------------------
Program-FORM CF -1R
Run--EXI STING+ADD
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied 116116indicated in the Special Features.
Modeling Assumptions section.s►j
DESIGNER or OWNERrN...
DOCUMENTATION AUTHOR
Name.... RALPH BAGGS CATHERINE M. MADLIN
Company. OWNER ny. Madlin's Enterprises
Address. 78-705 DESCANSO LANE ss. P.O. Box 1443
LA QUINTA, CA 92253 Palm Springs, CA 92262
Phone... 760-7 1271 Phone... 760-322-5004
License.
Signed.. J a3 Signed..
(date) (date)
ENFORCEMENT AGENCY
iZ-!Z•o3
Name.... Certified Energy AnaIyat
Title...
Agency.. Catherine M. Maddfln
NR 98-90.544
r r
Phone... r r R 98-90-144
Signed.. C A 4 E
i
—(date) ) Coiifornio Association of Wkkrg
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
=------------------------------------------------------------------------------
Page 1
MF -1R
-------------------------------------------------------------------------------
Project Title..........
BAGGS.ESTANCIA.3201
Date..12/12/03
12:35:36
Project Address........
78-705 DESCANSO LANE
******* ---------------------
RANCHO LA QUINTA _*v6.01*
Documentation Author...
CATHERINE M. MADLIN
*******
Building Permit
Madlin's Enterprises
P.O. Box 1443
Plan Check
Date
Palm Springs, CA 92262
760-322-5004
Field Check/
Date
Climate Zone...........
15
---------------------
Compliance Method......
-------------------------------------------------------------------------------
MICROPAS6 v6.01 for 2001
Standards by Enercomp,
Inc.
-------------------------------------------------------------------------------
MICROPAS6 v6.01
File-24005EA Wth-CTZ15S92
Program -FORM MF -1R
User#-MP0207
----------------------------------------------------------=--------------------
User-Madlin's Enterprises
Run-EXISTING+ADD
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents,the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE.MEASURES
--------------------------
i
.i
i *150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R -Value.
.j *150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U -factor in metal frame walls (does not apply
i to exterior mass walls).
Design-.Enforce-
er ✓. ment
NA
*150(d): Minimum R-13 raised floor insulation in framed floors.
150(1): Slab edge insulation - water absorption rate no greater
f than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets insulation quality
standards. Indicate type and form.
j 116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
I spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified U -factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
i 150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
'a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
j
V/
^4
NA
—4
NA
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R
=----------------------------------------------------------------=-------------
-------------------------------------------------------------------------------
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
Design- Enforce-
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Commission.
EKMII
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA.
✓
150(1): Setback thermostat on all applicable heating and/or
cooling systems.
EXE
150(j): Pipe and Tank insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating
sections of hot water system.
5. Cooling system piping below 55 degrees insulated.
6. Piping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and in-
sulated, to meet the requirements of the 1998 CMC sectons
601, 603, and 604, and standard 6-3; ducts insulated to a
minimum installed level of R-4.2 or enclosed entirely
in conditioned space. Openings.shall be sealed
with mastic, tape, aerosol sealant, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either
mesh
or tape shall be used. Building cavities shall not be used
for
conveying conditioned air. Joints and seams of duct systems
and
their components shall not be sealed with cloth back rubber
addhesive duct tapes unless such tape is used in combination
with
mastic and drawbands.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
✓
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12.35.36
• I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM MF -1R I
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-----------------------=-------------------------------------------------------
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr). AIA
4
LIGHTING MEASURES
-----------------
Design- Enforce-
er ment
150(k)1: Luminaires for general lighting in kitchens shall
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general lighting
shall be controlled bya switch on a readily accessible
lighting control panel at an entrance to the kitchen. /VA
150(k)2: Rooms with a shower or bathtub must have either at
least one luminaire with.lamps with an efficacy of 40
lumens/watt or greater switched at -the entrance to the
room or one of the alternatives to this requirement
allowed in Seca 150(k)2.; and recessed ceiling fixtures
are IC (insulation cover) approved.
Madlin -s
enterprises
Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ... . v
.Remodeled Building
4
ADDITION WORKSHEET Page 1 ADD
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
Project Address........ 78-705 DESCANSO LANE ******* ---------------------
• RANCHO LA QUINTA *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443• Plan C ec Date
f Palm Springs, CA 92262
760-322-5004 Fie C ec Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 x6.01 by Enercomp; Inc.
MICROPAS6 v6.01 File -24005A1 Program -ADDITIONS
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
I-------------------------------------------------------------------------------
ADDITION/ALTERATION WORKSHEET - COMPUTER PERFORMANCE
-------------------------=--------------------------
EXISTING
File Name. ..... ....... 24005A1 - EXISTING HOUSE
Conditioned Floor Area..... 2833 sf
Standard Design Energy Use. 39.96 kBtu/sf-yr
Proposed Design Energy Use. 78.40 kBtu/sf-yr
NEW (EXISTING PLUS ADDITION/ALTERATION)
File Name.. .. ........ 24005EA - EXISTING+ADD
Conditioned Floor Area..... 2946 sf
Standard Design Energy Use. 39.31 kBtu/sf-yr
Proposed Design Energy Use. 75.88 kBtu/sf-yr
FLOOR AREA RATIO Floor
Existing New Area
Floor Area Floor Area Ratio
---------- ------------- --------
2833 / 2946 0.962
DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION/ALTERATION)
Floor Addition/
New Area Existing Existing Alteration
Standard Ratio Proposed Standard Design
-----------------------
39.31. + 0.962 x ( 78.40 - 39.96) = 76.28
Note: If (Existing Proposed - Existing Standard) is
negative, this difference is set to zero.
---------------- -----------------------------------------------------
ADDITION/ALTERATION ENERGY USE SUMMARY =
_-------------------------------------- _
Addition/ _
Energy Use Alteration Proposed Compliance =
_ (kBtu/sf-yr) Design Design Margin =
-
New .................... 76.28 75.88 0.40 =
*** Addition/Alteration complies with Computer Performance
---------------------------------------------------------------------------
---------------------------------------------------------------------------
COMPUTER METHOD SUMMARY Page 1 C -2R
Projec t Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
Project Address........ 78-705 DESCANSO LANE ******* ---------------------
• RANCHO LA QUINTA *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs, CA 92262
760-322-5004 Field Check/ Date
Climate Zone............ 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------
MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance
_ (kBtu/sf=yr)
Design
Design
Margin
= Space Heating..........
3.48
2.24
1.24 =
= Space Cooling..........
35.83
73.64
-37.81 =
=
--------
Total 39.31
--------
75.88
-------- _
-36.57
_ ***
Water Heating not calculated
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 2946 sf
Building Type .............. Single Family Detached
Construction Type ......... Existing Plus Addition
Building Front Orientation. Front Facing 0 deg (N)
Number of Dwelling Units... 1
Number of Building Stories. 1
{ Weather Data Type.......... FullYear
Zone Type
----------
1.ZONE
.Residence
2.ZONE
Residence
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
2
29460 cf
2946 sf
27.5 % of floor area
0.5 Btu/hr-sf-F
0.63
10 ft
BUILDING ZONE INFORMATION
-------------------------
Floor # of Vent Vent Air
Area Volume Dwell Cond- Thermostat Height Area Leakage
(sf) (Cf) Units itioned Type (ft) (sf) Credit
------------ ----------------------- ----- -------- ---------
2833 28330 0.96 Yes Setback 2.0 Standard No
113 1130 0.04 Yes Setback 2.0 Standard No
COMPUTER METHOD SUMMARY Page 2 C-2R
-- -- ----------------------------
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
-----------------
----------------------------
MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program-FORM C-2R
User#-MPO207 User-Madlin's Enterprises Run-EXISTING+ADD i
-------------------------------------------------------------------------------
PERIMETER LOSSES
Form 3 Location/
Reference Comments
---------------------------
W.19.2X6.16
W.19.2X6.16
W.19.2X6.16
W.19.2X6.16
None
R.38.2X4.24
W.19.2X6.16
W.19.2X6.16
R.38.2X4.24
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1.ZONE - Existing
10 SlabEdge 247 0.760 R-0 No
2.ZONE - New
11 SlabEdge 22 0.760 R-0 No
FENESTRATION SURFACES
OPAQUE
SURFACES
Act
Area
U-
---------------
Insul
Act
Solar
Surface
(sf)
factor
R-val
Azm
Tilt
Gains
--------------
1.ZONE -
------
Existing
-----
-----
---
----
-----
1
Wall
400
0.065
17.8
0
90
Yes
2
Wall
487
0.065
17.8
90
90
Yes
4
Wall
177
0.065
17.8
180
90
Yes
6
Wall
663
0.065
17.8
270
90
Yes
7
Door
20
0.330
0
0
90
Yes
8
Roof
2829
0.025
38
n/a
0
Yes
2.ZONE -
New
19.0
0.720
0.700
90
90
3
Wall
66
0.065
17.8
90
90
Yes
5
Wall
62
0.065
17.8
180
90
Yes
9
Roof
113
0.025
38
n/a
0
Yes
PERIMETER LOSSES
Form 3 Location/
Reference Comments
---------------------------
W.19.2X6.16
W.19.2X6.16
W.19.2X6.16
W.19.2X6.16
None
R.38.2X4.24
W.19.2X6.16
W.19.2X6.16
R.38.2X4.24
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1.ZONE - Existing
10 SlabEdge 247 0.760 R-0 No
2.ZONE - New
11 SlabEdge 22 0.760 R-0 No
FENESTRATION SURFACES
Area
U-
Act
Exterior Shade
Interior Shade
Orientation
(sf)
factor
SHGC
Azm
Tilt
Type/SHGC
Type/SHGC
----------------------
1.ZONE - Existing
-----
-----
-----
---
----
--------------
--------------
1
Window
Front
(N)
48.0
0.480
0.650
0
90
Standard/0.76
Standard/0.68
2
Window
Front
(N)
18.0
0.720
0.700
0
90
Standard/0.76
Standard/0.68
3
Window
Front
(N)
24.0
0.720
0.700
0
90
Standard/0.76
Standard/0.68
4
Window
Left
(E)
190.9
0.480
0.650
90
90
Standard/0.76
Standard/0.68
5
Window
Left
(E)
19.0
0.720
0.700
90
90
Standard/0.76
Standard/0.68
6
Window
Left
(E)
18.8
0.480
0.650
90
90
Standard/0.76
Standard/0.68
7
Window
Back
(S)
48.0
0.480
0.650
180
90
Standard/0.76
Standard/0.68
8
Window
Back
(S)
141.4
0.480
0.650
180
90
Standard/0.76
Standard/0.68
9
Window
Back
(S)
18.8
0.480
0.650
180
90
Standard/0.76
Standard/0.68
10
Window
Right
(W)
166.9
0.480
0.650
270'
90
Standard/0.76'
Standard/0.68
11
Window
Right
(W)
1.0
0.720
0.700
270
90
Standard/0.76
Standard/0.68
12
Skylight
Horz
4.5
0.800
0.730
0
0
None/1
None/1
1.ZONE - New
13
Window
Left
(E)
25.0
0.450
0.450
90
90
Standard/0.76
Standard/0.68
2.ZONE - New
14
Door
Left
(E)
24.0
0.450
0.450
90
90
Standard/0.76
Standard/0.68
15
Window
Back
(S)
7.5
0.450
0.450
180
90
Standard/0.76
Standard/0.68
16
Door
Back
(S)
48.0
0.450
0.450
180
90
Standard/0.76
Standard/0.68
417
Window
Back
(S)
7.5
0.450
0.450
180
90
Standard/0.76
Standard/0.68
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12.35.36
---------------------------
MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM C -2R
I User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
SLAB SURFACES
Area
Slab Type (sf)
---------------- ------
1.ZONE
Standard Slab 2833
2.ZONE
Standard Slab 113
HVAC SYSTEMS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materials without additional compliance calculations.
The HVAC load calculations included in this compliance report
are for permit purposes only—The installing HVAC contractor
is responsible for determining the HVAC design loads and
equipment selection(s). The HVAC design shall be done in
accordance with industry standards. The load calculation in
this report considers ambient temperature loads, solar gain,
people and a fixed latent heat gain percentage. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The HVAC equipment is existing.
The night setback thermostat.
The eater heater is existing.
Refrigerant
Tested
ACCA
System
Minimum
Charge and Duct
Duct
Duct
Manual
Duct
Type
Efficiency
Airflow Location
R -value
Leakage
D
Eff
1'. ZONE
Furnace
0.780 AFUE
n/a Attic
R-4.2
No
No
0.743
ACSplit
12.00 SEER
No Attic
R-4.2
No
No
0.596
2.ZONE
Furnace
0.780 AFUE
n/a Attic
R=4.2
No
No
0.743
ACSplit
12.00 SEER
No Attic
R-4.2
No
No
0.596
REMARKS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materials without additional compliance calculations.
The HVAC load calculations included in this compliance report
are for permit purposes only—The installing HVAC contractor
is responsible for determining the HVAC design loads and
equipment selection(s). The HVAC design shall be done in
accordance with industry standards. The load calculation in
this report considers ambient temperature loads, solar gain,
people and a fixed latent heat gain percentage. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The HVAC equipment is existing.
The night setback thermostat.
The eater heater is existing.
CONSTRUCTION ASSEMBLY Page 1 3R
-----------------------------------------------=-----------=-------------------
-------------------------------------------------------------------------------
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
------------------=--=---------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM 3R
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
Parallel Path Method
Reference Name . W.19.2X6.16
Description .... Wall R-19 2x6 16oc
Type Wall
R -Value ........ 17.8 Hr-sf-F/Btu
Framing '
Material ..... FIR.2X6
Type .... Wood
Description .. 2x6 fir
Spacing ...... 16 inches on center
Framing Frac.. 0.15
---------------------------------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Total R -Value:
';r
1 / 0.065 = 15.28 hr-sf-F/Btu
Material
Cavity
Frame
Name
Description
R -Value
R-Value
0.
-------------
FILM.EX
----------------------------------------
Exterior air film: winter value
---------
0.17
---------
0.17
1.
STUCCO.0.88
0.875 in stucco
0.17
0.17
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3c.
BATT.R19
R-19 batt insul (cavity = 5.5 in)
17.80
--
3f.
FIR.2X6
2x6 fir
--
5.45
4.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R -Values
---------
19.34
---------
6.98
FRAMING ADJUSTMENT
CALCULATION
Cavity, Framing Total
U -Factor: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065
Btu/hr-sf-F
Total R -Value:
';r
1 / 0.065 = 15.28 hr-sf-F/Btu
CONSTRUCTION ASSEMBLY Page 2 3R
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:35:36
---------------------------------------------------------
• I MICROPAS6 v6.01 File-24005EA Wth-CTZ15S92 Program -FORM 3R
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
--------------------------------- Parallel Path Method
Reference Name . R.38.2X4.24
Description .... Roof R-38 2x4 24oc
Type ........... Roof
R -Value ........ 38 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type .... Wood
Description .. 2x4 fir
Spacing .... 24 inches on center
Framing Frac.. 0.07
---------------------------------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
------------------- ------------------- ----------------
U-Factor: (1 1 41.15 x 0.93) + (1 1 33.62 x 0.07) 0:025 Btu/hr-sf-F
Total R -Value: 1 / 0.025 = 40.51 hr-sf-F/Btu
Material.
Cavity
Frame
Name
Description
R -Value
R-Value
0.
-------------
FILM.EX
----------------------------------------
Exterior air film: winter value
---------
0.17
---------
0.17
1.
SHNGL.ASPHLT
Asphalt shingle roofing
0.44
0.44
2.
BLDG.PAPER
Building paper.(felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0.62
4.
AIR.RF.3.50
3.5 in & greater air space: heat flow up
0.80
0.80
5.
BATT.R27.0
R-27 batt insulation
27.00
27.00
6c.
BATT.RII.0
R-11 batt insul (cavity > 3.5 in)
11.00
--
6f.
FIR.2X4
2x4 fir
--
3.46
7.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.61
0.61
Total Unadjusted R -Values
---------
41.15
---------
33.62
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
------------------- ------------------- ----------------
U-Factor: (1 1 41.15 x 0.93) + (1 1 33.62 x 0.07) 0:025 Btu/hr-sf-F
Total R -Value: 1 / 0.025 = 40.51 hr-sf-F/Btu
Madlin's
enterprises
Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) .......
Existing Building
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:36:42
Project Address........ 78-705 DESCANSO LANE ******* ---------------------
• RANCHO LA QUINTA *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs, CA 92262
760-322-5004 Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File -24005A1 Wth-CTZ15S92 Program -FORM C -2R
i
User#-MP0207. User-Madlin's Enterprises Run -EXISTING HOUSE
-----------------------------------------=-------------------------------------
-- -----------------------------
= MICROPAS6 ENERGY USE SUMMARY =
----------------------------
Energy Use Standard Proposed Compliance =
(kBtu/sf-yr) Design Design Margin =
_----------------------------------------------------- _
= Space Heating.......... 3.58 2.19 1.39 =
= Space Cooling.......... 36.38 76.21 -39.83 =
Total 39.96 78.40 -38.44 =
Water Heating not calculated
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 2833 sf
Building Type .............. Single Family Detached
Construction Type ....... Existing
Building Front Orientation. Front Facing 0 deg (N)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
i
i
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.......:.
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
28330 cf
2833 sf
27.5 % of floor area
0.5 Btu/hr-sf-F
0.65
10 ft
BUILDING ZONE INFORMATION
Floor
# of
Vent Vent
Air
Area Volume
Dwell Cond- Thermostat
Height Area
Leakage
Zone Type (sf) (cf)
-------------- -------- ----
Units itioned Type
-----
(ft) (sf)
Credit
1.ZONE
------------------
-------------
---------
Residence 2833 28330
1.00 Yes Setback
2.0 Standard
No
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12.36.42
-------------------------------------------------------------------------------
• I MICROPAS6 v6.01 File -24005A1 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -EXISTING HOUSE `
-------------------------------------------------------------------------------
OPAQUE SURFACES
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
-.ZONE - Existing
7 S1abEdge 268 0.760 R-0 No
FENESTRATION SURFACES
!
Area
U-
Insul
Act
U-
Solar
Form 3 Location/
Surface
(sf)
factor
R-val
Azm
Tilt
Gains
Reference Comments
--------------
1.ZONE -
------
Existing
-----
-----
---
----
-----
------------ ----------------
1 Wall
400
0.065
17.8
0
90
Yes
W.19.2X6.16
2 Wall
577
0.065
17.8
90
90
Yes
W.19.2X6.16
3 Wall
248
0.065
17.8
180
90
Yes
W.19.2X6.16
4 Wall
663
0.065
17.8
270
90
Yes
W.19.2X6.16
5 Door
20
0.330
0
0
90
Yes
None
6 Roof
2829
0.025
38
n/a
0
Yes
R.38.2X4.24
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
-.ZONE - Existing
7 S1abEdge 268 0.760 R-0 No
FENESTRATION SURFACES
!
Area
U-
Act
Exterior Shade
Interior Shade
Orientation
(sf)
factor SHGC
Azm
Tilt
Type/SHGC
Type/SHGC
----------------------
1.ZONE - Existing
-----
-----
-----
---
----
--------------
--------------
1
Window
Front
(N)
48.0
0.480
0.650
0
90
Standard/0.76
Standard/0.68
2
Window
Front
(N)
18.0
0.720
0.700
0
90
Standard/0.76
Standard/0.68
3
Window
Front
(N)
24.0
0.720
0.700
0
90
Standard/0.76
Standard/0.68
4
Window
Left
(E)
215.9
0.480
0.650
90
90
Standard/0.76
Standard/0.68
5
Window
Left
(E)
19.0
0.720
0.700
90
90
Standard/0.76
Standard/0.68
6
Window
Left
(E)
18.8
0.480
0.650
90
90
Standard/0.76
Standard/0.68
7
Window
Back
(S)
48.0
0.480
0.650
180
90
Standard/0.76
Standard/0.68
8
Window
Back
(S)
195.40.480
0.650
180
90
Standard/0.76
Standard/0.68
9
Window
Back
(S)
18.8
0.480
0.650
180
90
Standard/0.76
Standard/0.68
10
Window
Right
(W)
166.9
0.480
0.650
270
90
Standard/0.76
Standard/0.68
11
Window
Right
(W)
1.0
0.720
0.700
270
90
Standard/0.76
Standard/0.68
12
Skylight
Horz
4.5
0.800
0.730
0
0
None/1
None/1
I
SLAB SURFACES
-------------
Area
Slab Type
----------------
(sf)
1.ZONE
------
Standard
Slab
2833
COMPUTER
METHOD SUMMARY
Page 3
C -2R
Project Title.......... BAGGS.ESTANCIA.3201
Date..12/12/03 12:36:42
----------------------------------------
MICROPAS6 v6.01 -File-24005A1 Wth-CTZ15S92
Program -FORM C -2R
--------7----------------------------------------------------------------------
User#-MP0207 User-Madlin's Enterprises
Run -EXISTING HOUSE
HVAC SYSTEMS
------------
Refrigerant
Tested ACCA
System
Minimum Charge and Duct
Duct Duct Manual
Duct
Type
Efficiency Airflow Location R
-value Leakage D
Eff
-------------
1.ZONE
--------------------------------------
-----------------
----
Furnace
0.780 AFUE n/a Attic
R-4.2 No No
0.743
ACSplit
12.00 SEER No Attic
R-4.2 No No
0.596
REMARKS
The values and materials used in this existing house Micropas
run was obtained from the original house CF -1R issued on
9/10/93. A copy of this document is included in the addendums
and notes section of this report.
Madlin -s
enterprises
Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ®®®®v
vv
H. V.A. C. Load Calculation
HVAC SIZING Page 1 HVAC
-------------------------------------------------------------------------------
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:42:56
Project Address........ 78-705 DESCANSO LANE ******* ---------------------
RANCHO LA QUINTA *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date.
Palm Springs, CA 92262
760-322-5004 Field Check/ Date
Climate Zone. ..... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
--------- --------------------------------------------------------------
f MICROPAS6 v6.01 File-24005EA Program -HVAC SIZING
I User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area ................. 2946 sf
Volume.. ............ 29460 cf
Front Orientation.......... Front Facing 0 deg (N)
Sizing Location............ PALM DESERT
Latitude... .... ... .. 33.7 degrees
Winter Outside Design ....... 32 F
Winter Inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range.. ...... 34 F
Interior Shading Used No
Exterior Shading Used...... No
Overhang Shading Used...... No
Latent Load Fraction....... 0.20
HEATING AND COOLING
LOAD SUMMARY
--------------------------------
Heating
Cooling
Description
---------------------------------
(Btuh)
(Btuh)
Opaque Conduction and Solar......
-----------
15393
-----------
8022
Glazing Conduction ...............
15291
13681
Glazing Solar ....................
n/a
32374
Infiltration .....................
15556
10295
Internal Gain ....................
n/a
2532
Ducts. ....................
4624
6690
Sensible Load ....................
50863
73594
Latent Load ......................
n/a
14719
Minimum Total Load
50863
88313
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements,. outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
HVAC SIZING Page 2 HVAC
-------------------------------------------------------------------------------
Project Title.......... BAGGS.ESTANCIA.3201 Date..12/12/03 12:42:56
--------------------------------------------------------
MICROPAS6 v6.01 File-24005EA Program -HVAC SIZING
User#-MP0207 User-Madlin's Enterprises Run-EXISTING+ADD
-------------------------------------------------------------------------------
HEATING AND COOLING LOAD SUMMARY BY ZONE
----------------------- =----------------
ZONE '1.ZONE'
Floor Area ....................... 2833 sf
Volume ........................... 28330 cf
Heating
Cooling
Description
---------------------------------
(Btuh)
(Btuh)
Opaque Conduction and Solar......
-----------
14333
-----------
7601
Glazing Conduction ...............
. 13803
12350
Glazing Solar....... ...........
n/a
30352
Infiltration .....................
14960
9900
Internal Gain...... ............
n/a
2448
Ducts ............................
4310
6265
Sensible Load ....................
47405
68916
Latent Load......................
n/a
13783
Minimum Zone Load
-----------
47405
-----------
82699
ZONE 12.ZONE'
Floor Area .......................
113 sf
Volume ...........................
1130 cf
Heating
Cooling
Description
---------------------------------
(Btuh)
(Btuh)
Opaque Conduction.and Solar......
-----------
1060
-----------
421
Glazing Conduction ...............
1488
1331
Glazing Solar ....................
n/a
2022
Infiltration .....................
597
395
InternalGain ....................
n/a
84
Ducts ............................
314
425
Sensible Load ....................
3459
4678
Latent Load ......................
n/a
936
Minimum Zone Load
-----------
3459
-----------
5614
Madlin's
enterprises
Catherine M. Madlin, Certified EnergyAnalyst • 760-322-5004 / 323-3644 (fax) ®®®®®v
Addendums and Notes
I + 64" -5
` ,
Ad i
NE -i505?
XATCH !L'.'4.cT G.
A46 JR -
I' A
ryp.!
rci.11 Tez
r7
HALLO TG LC
+ �I A -,
DEN
All� OF 3080
�zvi r
I_F4I1N6H BOORS AITH
r ri- NkElPi F4AL 5 �c
(113 50. FT.) F '15TNC,
!EOUAL LXAL
.... -- --- —• - i __; ._ .. — __ ....._ _._.... ��-...._ .'•--' - -F3n:V`1�7i - j +
F.r
-0
PARTIAL FLOOR PLAN (113SOFrs I
-A
In
C'
E,
ryINDnWFILL 1: 'XlST1NG
AREA OF ADDITION
NU'iM r4AI11 5 TO
MATCH Ei<!5TINr,
I + 64" -5
` ,
Ad i
NE -i505?
XATCH !L'.'4.cT G.
A46 JR -
I' A
ryp.!
rci.11 Tez
r7
HALLO TG LC
+ �I A -,
DEN
All� OF 3080
�zvi r
I_F4I1N6H BOORS AITH
r ri- NkElPi F4AL 5 �c
(113 50. FT.) F '15TNC,
!EOUAL LXAL
.... -- --- —• - i __; ._ .. — __ ....._ _._.... ��-...._ .'•--' - -F3n:V`1�7i - j +
F.r
-0
PARTIAL FLOOR PLAN (113SOFrs I
-A
In
C'
i2 • �•rh,
PAGE 02
12- 11-o3
t
CBRTIFICAS9 OF Ci>64?LIANCE: Residential (pert 1 of 2) CF -1R paga, 3 or 13
Project Nam e: The Orchard (Entancia 3201) pat®: 9/10/&993
Address: =
Lai Quinta, CaliforniaBuIlding Ti—rTail-R-a-
Designer: Robert taab Haxt ry J,'a -
Documentation: ,aber3 Dodd Associates 1COMPLY 24 User 1000
CFNERAL INp"RKATION
Ccmplianca Method:
COMPLY 24 version 4, 11
-�
y
Climate Zone:
is
Conditioned Floor Area:
2831 @aft.
Buildinq Types
Single !aa Cast
r.
Buildinq Front orientation:
Four Cardinal Orientations
Number of Dwalling Units:
1
Floor Construction Type:
Slab on Grade
�.
AUILDING SHPI.L INSULATION
Ccsnporaeent 0-Ytloagi Location/Coaments
R-19 Wall (90.19.2x5.16) -0.065
esstarci.a 3201 --P_._____-_______..__
R-'38 Roof(R.a8.2x14..16)
0.026 Estancia 3201
Slab Perimeter v/R-0.0
0.720 Estancia 3201
FENFST ATION
Shads-nq Devices
Frame!
Orient, Area U -9a1 Type
-- --48.9
Interior F.xkarior OH 5P Type
Front- 0,48 Doubles
Std DrapeStandard' Bitq-Ser 1Y
N Vinyl
Front 1.8.0 0.77 Douhlo
Std Drape Standard Bug Scr Y
N Done
3roeit 24.0 0.73 Doublm
Std Drape 5tandaird Dug Scr Y
N Voila
Lsrt 215.4 0.48 Double
Std Drape Standards Bug Scr x
N Vinyl
Lea rt 19.0 0.72 Double
Std Drape Standard Bug Sar Y
N Atone
�^
14 ft 18.8 0.46 Double
Std Drape Standard Bug Scr X
X Vinyl
Beck 48.0 0.44 Daubi®
S�.d Drape Standard Bug Scr y
R V.lnyl
Back 195.4 0.46 Doubler
9 Drape Standard Bug Scr. Y
N Vinyl
Back 18.6 0.48 Double
Drape Standard Bug Scr Y
N Vinyl
Right 166.9 0.49 Double
S Drape Standard Bug Scr Y
N Vinyl
Right 1.0 0.72 Double
Std Drapa Standard Bug Scr Y
9 None
Skylight 4.3 0.80 wuhlo
none node N
N Metal
-
THE1t!l.4.i. MASS
Area Thirk
Type
.._...--------------Crna-ri.r4q
(a!)- (in)- Lavation/De4aCripCiotl
Concrete, Heavyweight Cw4*rsd
_-----.
3939 3.50 Slab an Gmde
_
Frame Wall, Gyp. Board_ Exposed
4949 0.63 Lstancis 3201/Int Raps
Masonry, Solidi Crout Expoffied
48 6.00 Estancia 3101/Int Naga
CEWITICATE OF CMLIANCE: Residential (part 2 of 2) CF -1R page
4 of 13
Project ~Name: The Orchard w(SatAncia 31201)-----------�-Date- -9/10/1993-'-
1COMPLY
Documentation: Gabel Dodd Associates
24 User 1000
G
__------_.-_.-__�....__._..
J
HVAC SYSTERS Kiniaum D10tri.b Type Duct TStat
System Type Efficiency am Location
Real Type Location/Comments
t
(Z•v��3
SpltAirCond12.100 SEAR Ducts in Actio 9.4 o+a..a.vw
Nater No. 'tank Ext -
WATER HEATING SY5TM3 Hestor In Margy Size Insul
Syst4ata°+Name
__ _---_-__-- Distribution Typm Type--- Bye Factor (gal) R_Val
AIUMChN AP? GX2F9Q-754 Reaire-TA%e4T%asp Sto r0ax 1 0.53 66.4 12.0
MM
WATER MUTZ. ZQUIPKZn DETAIL %Aeo Rated Stdby TarA pilot
System mama System Type Eff Input Yves R -Val Light
AMMUCAN APP Mr'40-754 Daa4etiCIM 0.760 5098 0.000 0.0 0
SPECIAL FFA`1YDM!VEKAM
COKPLrAtZCx STATENUM
This Certificat.s of Compliance lists the building features and performance
s�ecitications neaded to comply with Title 24, Parts 1 6 4 of the Califor-
n:.aa Code of A&;aiatiens, and the adnirti+istrative raguulationaa to iuplezcnt
them. This certifir_ato has ben signed by the individual with overall
design responsibility. when thin certificate of compliance is submitted Per
a single, building plan to be built in multiple orlsntations, any shading.
feature that is varied is indicated in the Spacial FeaYtures/Ramar" section
DP.MMER or QidNM DOCUM"ATION AUTHOR
(Per Business 4 Professions Cods) Kisti Rruc:ari
Robert Lamb Hart Cabal Dodd Associates
243 Californias Street 761 Sir Francis Drake Blvd
Smn Francisco, California San iAnselmo, CA 44960
�.— — Lir ---- - (415) 436-75as
(signature)— Hate atusa ante
ENFORCMt rs AGCY
man*:
Title •'-'"""-"
Agency:
Telephone:
�a're� aF ash+ atej
yes !: ��p•�a� at :. •oomt �t:..+a.�t • ...
2
-n
C