Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-4618 (SFD) Title 24
TITLE 24 REPORT Title 24 Report for: Ed & Marlies Artzt Residen Lot 97 -Traditions La Qu i nta, Ca 92253 Project Designer: CITY OF IA QUINTA BUILDING & SAFETY DEPT. AP P RO V E FOR CONS ` ION BY DATE ` BBG Architects 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 (714) 434-2506 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 - .. (760) 340-3088 Job Number: Date: 7/1/04 .-E The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 is r Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Ed & Marlies Artzt Residence 7/1/04 roiec Title -Date Lot 97 -Traditions La Quinta H & H Air Conditioning (760) 340-3088 ocumen a ion Author lelephone Computer Performance 15 Field Check a e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 5,414 f?Average Ceiling Height: 12.4 ft Total Conditioned Slab Area: 5,414 f? Building Type: (check one or more) ® Single Family Detached F]Addition F-1Single Family Attached ❑ Existing Building F-1Multi-Family❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: 0 Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 F -]Raised Floor BUILDING SHELL INSULATION Component Type R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Slab On Grade Slab On Grade R-30 Roof(R.30.2x4.24) Solid Wood Door FENESTRATION Frame Type Wood Wood n/a n/a Wood None Assembly Location/Comments U -Value (attic, garage, typical, etc.) 0.028 Exterior Roof 0.059 Exterior Wall 0.756 Covered Slab w/R-0.0 Perimeter Insulation 0.756 0.031 0.387 Exposed Slab w/R-0.0 Perimeter Insulation Exterior Roof Exterior Door Shading Devices Type Building Permi Plan Check ate Exterior Overhang Side Fins H & H Air Conditioning (760) 340-3088 ocumen a ion Author lelephone Computer Performance 15 Field Check a e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 5,414 f?Average Ceiling Height: 12.4 ft Total Conditioned Slab Area: 5,414 f? Building Type: (check one or more) ® Single Family Detached F]Addition F-1Single Family Attached ❑ Existing Building F-1Multi-Family❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: 0 Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 F -]Raised Floor BUILDING SHELL INSULATION Component Type R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Slab On Grade Slab On Grade R-30 Roof(R.30.2x4.24) Solid Wood Door FENESTRATION Frame Type Wood Wood n/a n/a Wood None Assembly Location/Comments U -Value (attic, garage, typical, etc.) 0.028 Exterior Roof 0.059 Exterior Wall 0.756 Covered Slab w/R-0.0 Perimeter Insulation 0.756 0.031 0.387 Exposed Slab w/R-0.0 Perimeter Insulation Exterior Roof Exterior Door Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Left (North) 12.0 0.54 0.46 Bug Screen ❑ X❑ ❑ Q Left (North) 99.5 0.60 0.46 Bug Screen ❑ Q ❑ XD Rear (East) 45.0 0.60 0.46 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 100.0 0.54 0.46 Bug Screen El XD El XRear (East) 80.0 0.55 0.46 Bug Screen ❑ XD ❑ X❑ Right (South) 12.5 0.54 0.46 Bug Screen ❑ X❑ ❑ x0 Left (North) 60.0 0.55 0.46 Bug Screen ❑ x❑ElXLeft (North) 60.0 0.55 0.46 Bug Screen o ❑ 1:1o Right (South) 30.0 0.60 0.46 Bug Screen © ❑ ❑ ❑x Right (South) 80.0 0.55 0.46 Bug Screen ❑ X❑ ❑ ❑x Front (West) 78.0 0.60 0.46 Bug Screen ❑ X❑ 11 IF] Front (West) 34.0 0.54 0.46 Bug Screen ❑ © ❑ ❑X Run Initiation Time: 07/01/0414:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 42 • • r Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Ed & Marlies Artzt Residence 7/1/04 Project Title Date Lot 97 -Traditions La Quinta rroject Aaaress H & H Air Conditioning (760) 340-3088 ocumen a ion u orTelephone Computer Performance 15 E3uilding ermi Plan Check I Date Field ec Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 5,414 ft2 Average Ceiling Height: 12.4 ft Total Conditioned Slab Area: 5,414 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: 0 Slab Floor Number of Dwelling Units: 1.00 Number of Stories: BUILDING SHELL INSULATION Component Type FENESTRATION ❑ Raised Floor Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Rear (East) 200.0 0.55 0.46 Bug ScreenX❑ ❑ ❑ ❑x Front (west) 106.0 0.54 0.46 Bug Screen X❑ El X❑ Front (West) 49.8 0.55 0.46 Bug Screen ❑X ❑ ❑ X❑ Left (North) 10.0 0.60 0.46 Bug Screen N 11 El xD Right (South) 78.6 0.60 0.46 Bug Screen ❑ K ❑ Q Rear (East) 40.0 0.54 0.46 Bug Screen Q ❑ ❑ Q 1:1 El ❑❑ 1:1 El El F] El 11 F1 1:1 El 11 1:1 El 1:1 El ❑ D ❑ ❑ Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 42 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Ed & Marlies Artzt Residence 7/1/04 -project Title a e HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Ducts in Attic 4.2 Distribution Split Air Conditioner 13.0 SEER Ducts in Attic Heating Equipment Minimum Type and Duct or Ducts in Attic 4.2 Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -4 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -5 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc.) Duct Thermostat Location / R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -4 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -5 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN CG32-100T88- Large Gas Recirc/Time+Temp 1 88,000 96 0.82 0.0239 0.0 SMITH FPS -50-224 Small Gas Recirc/Time+Temp 1 43,000 50 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: BBG Architects Address: 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 Telephone: (714) 434-2506 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: • Address: Telephone: Name: Tim Scott Title/Firm: H & H Air Conditioning Address: 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 Telephone: (60) 340-30EP � d 4- (si (date) signature stamp ate Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 42 Certificate of Compliance: Residential (Addendum) CF -1 R OEd & Marlies Artzt Residence 7/1/04 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field C7 • The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 479 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 417 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 518 sqft Covered Slab Floor, 3.50" thick at Guest Suite & Office HIGH MASS Design(see C-211) - Verify Thermal Mass: 331 sqft Exposed Slab Floor, 3.50" thick at Guest Suite & Office The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1043 sqft Exposed Slab Floor, 3.50" thick at Living/Dining/Entry The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS FJI VYIYCI. an Field The HVAC System includes Refrigerant Charge and Airflow Credit (ora certified HhKb rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. e System includes Refrigerant Charge and Airflow credit (ora certmea HhK5 rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System includes Refrigerant Charge and Airflow Credit (ora TXVF-A—ce-ff ified HERS rater—m—usT-provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run InitiationTime: un Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 42 Certificate of Compliance: Residential (Addendum) CF -1 R *Ed & Marlies Artzt Residence 7/1/04 Project Title Date • • Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )aseo on ine aoequacy or ine speciai jusuncauon ano aocurnemauon suonnueu. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 236 sqft Covered Slab Floor, 3.50" thick at Kitchen/Family/Nook HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1140 sqft Exposed Slab Floor, 3.50" thick at Kitchen/Family/Nook The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -5" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 646 sqft Covered Slab Floor, 3.50" thick at Casita HIGH MASS Design(see C -2R) - Verify Thermal Mass: 604 sqft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an Field Run InitiationTime: un Code: 108871907T- EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:7 of 42 n • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ® '§150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ® to not apply exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §'150(l): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no E] greater than 2.0 perm/inch. ® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. ®§150(i): Setback thermostat on all applicable heating and/or cooling systems. ® § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or -R-1 6 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 42 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk • (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • C J DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) (XI ' § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. [X] § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) © §118 (f): Cool Roof material meet specified criteria Lighting Measures § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. !- §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5533 Job Number: Page:9 of 42 Computer Method Summary (Part 1 of 3) C -2R +Ed & Marlies Artzt Residence 7/1/04 Project Tit a -Da Fe — Lot 97 -Traditions La Quinta -Project Ad- ress H & H Air Conditioning (760) 340-3088 -Documentafion Au oto— eleprione Computer Performance 15 -C —I' nce efhoa 1 —1— . — om u erCli i Ione � omp is g p ma a Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating Space Cooling Domestic Hot Water Totals 4.23 4.24 0.00 37.75 35.46 2.29 5.26 6.82 -1.56 —4-7.2-5— 7.2 46.52 0.73 Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name HVAC -1 •HVAC -2 HVAC -3 HVAC -4 • 5,414 Single Fam Detached (West) 270 deg 1.00 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area. Volume Roof 896 0.028 0 20 Wall 280 0.059 0 90 Wall 244 0.059 90 90 Wall 274 0.059 180 90 Roof 849 0.028 0 20 Wall 538 0.059 0 90 Wall 175 0.059 180 90 Wall 220 0.059 270 90 Roof 1,043 0.028 0 20 Wall 440 0.059 90 90 Wall 370 0.059 270 90 Roof 1,376 0.031 0 0 Wall 305 0.059 0 90 Wall 200 0.059 90 90 Wall 551 0.059 180 90 Wall 279 0.059 270 90 Door 21 0.387 270 90 Roof 1,250 0.028 0 0 Wall 360 0.059 0 90 Wall 280 0.059 90 90 Wall 390 0.059 180 90 Wall 338 0.059 270 90 896 849 1.043 1,376 o ar Gains Y/N BuildingPermit # P an Ceh cate Field Cehcate XO Slab Floor Floor Construction Type: F Raised Floor Total Fenestration Area: 21.7% Total Conditioned Volume: 67,010 Slab Floor Area: 5,414 # of Thermostat Vent Units Zone Type Type Hgt. Area 10,035 0.17 Sleeping SleepingStat 2 n/a 8,490 0.16 Sleeping SleepingStat 2 n/a 19,817 0.19 Living LivingStat 2 n/a 16,168 0.25 Living LivingStat 2 n/a Form 3 Reference R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-30 Roof(R.30.2x4.24) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Solid Wood Door R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (YV.21.2x6.16) Location / Comments Master Suite Master Suite Master Suite Master Suite Guest Suite & Office Guest Suite & Office Guest Suite & Office Guest Suite & Office Living/Dining/Entry Living/Dining/Entry Livin /Dining/Entry Kitchen/Family/Nook _ Kitchen/Family/Nook Kitchen/Family/Nook Kitchen/Family/Nook Kitchen/Family/Nook Kitchen/Family/Nook Casita Casita Casita Casita Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 42 1 r'. Computer Method Summary (Part 1 of 3) C -2R Ed & Marlies Artzt Residence 7/1/04 Project Title a e Lot 97 -Traditions La Quinta -Pro)ecFXd- ress H & H Air Conditt�g (760) 340-3088 -Documentatio"amu or I a ep one Computer Performance 15 Buiraing�Pe�mit # Plan Check/Date Field C1 eck/Da e Comp iance ethu C (Pac age or ompu er ima a one Source Energy Use Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 4.23 4.24 0.00 Space Cooling 37.75 35.46 2.29 Domestic Hot Water 5.26 6.82 -1.56 Totals –47—.T5-- 46.52 0.73 • UtNtKAL INI-UKMA I IUN [XI Slab Floor Conditioned Floor Area: 5,414 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 21.7% Number of Dwelling Units: 1.00 Total Conditioned Volume: 67,010 Number of Stories: 1 Slab Floor Area: 5,414 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC -5 1.250 12,500 0.23 Sleeping Sleeping Stat 2 Na OPAQUE SURFACES Act. Type Area U -Fac. Azm Tilt Solar Gains Y / N Form 3 Reference Location / Comments Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 42 Computer Method Summary (Part 2 of 3) C -2R Ed & Marlies Artzt Residence 7/1/04 Prof-'ect Title Date U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Left North 12.0 0.540 0.46 0 90 Double NonMtl Tinted Master Suite 2 Window Left (North) 12.5 0.600 0.46 0 90 Double NonMtl Tinted Master Suite 3 Window Rear (East) 12.5 0.600 0.46 90 90 Double NonMtl Tinted Master Suite 4 Window Rear (East) 12.5 0.600 0.46 90 90 Double NonMtl Tinted Master Suite 5 Window Rear (East) 16.0 0.540 0.46 90 90 Double NonMtl Tinted Master Suite 5 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Master Suite 7 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Master Suite 8 Window Rear (East) 16.0 0.540 0.46 90 90 Double NonMtl Tinted Master Suite 9 Window Right (South) 12.5 0.540 0.46 180 90 Double NonMtl Tinted Master Suite 10 Window Left (North) 6.0 0.600 0.46 0 90 Double NonMtl Tinted Guest Suite & Office 11 Window Left (North) 10.0 0.600 0.46 0 90 Double NonMtl Tinted Guest Suite & Office 12 Window Left (North) 10.0 0.600 0.46 0 90 Double NonMtl Tinted Guest Suite & Office 13 Window Left North 20.0 0.550 0.46 0 90 Double NonMtl Tinted Guest Suite &Office 14 Window Left (North) 20.0 0.550 0.46 0 90 Double NonMtl Tinted Guest Suite & Office 15 Window Left (North) 6.0 0.600 0.46 0 90 Double NonMtl Tinted Guest Suite & Office 16 Window Right (South) 10.0 0.600 0.46 180 90 Double NonMtl Tinted Guest Suite & Office 17 Window Right (South) 20.0 0.550 0.46 180 90 Double NonMtl Tinted Guest Suite & Office 18 Window Right (South) 20.0 0.550 0.46 180 90 Double NonMtl Tinted Guest Suite & Office 19 Window Front' (West) 18.0 0.600 0.46 270 90 Double NonMtl Tinted Guest Suite & Office 20 Window Front (West) 18.0 0.600 0.46 270 90 Double NonMtl Tinted Guest Suite & Office 21 Window Front (West) 18.0 0.540 0.46 270 90 Double NonMtl Tinted Guest Suite & Office 22 Window Front (West) 6.0 0.600 0.46 270 90 Double NonMtl Tinted Guest Suite & Office 23 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Living/Dining/Entry 24 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Living/Dining/Entry 25 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Living/Dining/Entry 26 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Living/Dining/Entry TiVll'ndow Rear(Las t) -20.0- -9.550- -0.46 9-0- -90 Douuble Nonm I Tin ed -Living/Dining/Entry - 28 Window Rear (ast -20-0- 0-550 0-46 99 90 Double on rTinFed -Living/Dining/Entry - 29 Window Rear (East) 20.0 0.550 0.46 90 90 Double NonMtl Tinted Living/Dining/Entry INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGCg- t-wa- en. Hgt. xt. Ex -t. -Dist. Len. gt. -Dist. Len. Hgi. 1 -Bug Screen 0:76 2 Bug Screen 0.76 5 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8- Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen O.Tfi 12 Bug Screen -0-.T6- Tfi11 1-1 Bug Screen 0-M 1-4 Bug Screen 0-76- 8.0 2.5 0.0 0.0 0.0 0.0 15 Bug Screen -0:76- 1fi Bug Screen 0:76- 4.0 2.5 6.0 0.1 6.0 6.0 17 Bug Screen 0.76 18 Bug Screen 0:76- 19 Bug Screen O:Tfi MuE ugg Screen -"g- 21 Bug Screen 0-M 22 Bug Screen 0.76 23 Bug Screen 0.76 8.0 2.8 10.0 0.1 10.0 10.0 24 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 25 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 26 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 27 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 28 Bug Screen 0.76 -W0 --I5 X0.0 -6-1 ITO -6.0 29 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 Run Initiation Time: 07/01/0414:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 12 of 42 Computer Method Summary (Part 2 of 3) C -2R Ed & Marlies Artzt Residence 7/1/04 Project Tit a Date # Type 30 31 32 33 94- Y5 36 37 38 39 40 41 -4-2- 43 44 45 46 47 48 49 50 Window Rear (East) Window Rear (East) Window Rear (East) Window Rear (East) Window Rear (East) Window Front (West) Window Front (West) Window Front (West) U - Area Factor SHGC 20.0 5.0 5.0 5.0 5.0 48.0 24.9 24.9 48.0 5.0 5.0 5.0 5.0 12.5 12.5 20.0 20.0 10.0 10.0 24.0 20.0 51 Window Rear (East) Left Fin Right Fin 20.0 52 Window Rear (East) U-5. gfTt: L -Ext. 24.0 53 Window_ Right (South) 15.0 54 Window Right (South) 15.0 55 Window Right (South) -2-0.0- 0.0in i dowigfit(SoutFi) Bug Screen 0.76 -20-.0- 57 Win ow ffi-g-(So�Fi) f17.Y 58 Window Right (South) 11.3 INTERIOR AND EXTERIOR SHADING 0.550 0.540 0.540 0.540 0.540 0.540 0.550 0.550 0.540 0.540 0.540 0.540 0.540 0.600 0.600 0.550 0.550 0.600 0.600 0.540 0.550 0.550 0.540 0.600 0.600 0.550 -0350- CF600- 0.600 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 -0:467 o�s 0.46 Act. Azm. 90 90 90 90 90 270 270 270 270 270 270 270 270 0 0 0 0 0 0 90 90 90 90 180 180 180 "0- --T80 180 Glazing Type Tilt 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 Double NonMtl Tinted 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 -9g. �JO 90 Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Location/ Comments Livin /Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Living/Dining/Entry Uouble on tl Tinted -Ki c of n7Family/Nook Double NonMtl TintedKim a /Family/Nook Doub a NonMtl Tinted Kitchen/Family/Nook Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 13 of 42 Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC -R-g-t- U-5. gfTt: L -Ext. RExt. -Dist.-Len. HT -Dist. Len. H§I. -30 Bug Screen 0:78 IF0 2.5 TO -0 0-1-T0-0 t0-0 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 36 Bug Screen 0.76 8.3 3.0 6.0 0.1 6.0 6.0 37 Bug Screen -0:76- -9-3 3-0 ' 6-0 0-1 -60 6-0 38 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 39 Bug Screen 0.76 40 Bug Screen -0-.Ts- -. f41- 4-1- Bug Screen 0-76- 2.0 2.5 0.0 0.0 0.0 0.0 42 Bug Screen -O-T6 2.0 2.5 0.0 0.0 0.0 0.0 43uE-gg Screen --0-M 44 Bug Screen -T76- :7fi45 45 Bug Screen -0-r6 8.0 2.5 10.0 0.1 10.0 10.0 46 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 47 Bug Screen 0:76- --4.-0 23 -60 01 6:0 -60 48 Bug Screen 0-M 49 Bug Screen -M 50 Bug Screen - -0M 5-I Bug Screen 0.76 52 Bug Screen 0.76 _ 53 Bug Screen 0.76 _ 54 Bug Screen 0.76 55 Bug Screen 0.76 Bug Screen 0.76 5.56 57 Bug Screen 0.76 58 Bug Screen 0.76 Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 13 of 42 Computer Method Summary (Part 2 of 3) C -2R •Ed & Marlies Artzt Residence 7/1/04 ro/ect Ttt a Date # Type Area U- Factor SHGC Act. Azm. Tilt 8.0 0.600 0.46 180 90 8.0 0.600 0.46 180 90 10.0 0.600 0.46 0 90 10.0 0.600 0.46 0 90 20.0 0.550 0.46 0 90 20.0 0.550 0.46 0 90 10.0 0.600 0.46 90 90 10.0 0.600 0.46 90 90 20.0 0.540 0.46 90 90 20.0 0.550 0.46 90 90 20.0 0.550 0.46 90 90 20.0 0.540 0.46 90 90 10.0 0.600 0.46 180 90 10.0 0.600 0.46 180 90 10.0 0.600 0.46 180 90 15.0 0.600 0.46 270 90 15.0 0.600 0.46 270 90 6.0 0.540 0.46 270 90 6.0 0.600 0.46 270 90 Glazing Type Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Location/ Comments Kitchen/Family/Nook Kitchen/Family/Nook Casita Casita Casita Casita Casita Casita Casita Casita Casita Casita Double NonMtl Tinted Casita Double NonMtl Tinted Casita Double NonMtl Tinted Casita Double NonMtl Tinted Casita Double NonMtl Tinted Casita Double NonMtl Tinted Casita Double NonMtl Tinted Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC -Hgt.--Wd-. Len. Hgt. LEA REA -Dist: eC n. HT. -Dist: Len. Hg[. -59 Bug Screen 0:76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 66 Bug Screen OTfi 67 Bug Screen 0.76 8.0 2.5 8.0 0.1 8.0 8.0 68 Bug Screen 0.76 8.0 2.5 8.0 0.1 8.0 8.0 69 Bug Screen 0�6- 8:0 --Y5 --Y0 0.9 8:0 --8-0 .7.0 Bug Screen -0:76- 8.0 2.5 8.0 0.1 8.0 8.0 '71 BugScreen -O-T6 4.0 2.5 6.0 0.1 6.0 6.0 -72 8 -ug -O-T6- "73 BugScreen -0:76 4.0 2.5 --2F0 0-1 --T0 4-0 -74 Bug Screen 076- 75 Bug Screen 0.76 76 Bug Screen 076 y7 Bug Screen 0:76 Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 42 Computer Method Summary (Part 3 of 3) C -2R Ed & Marlies Artzt Residence 7/1/04 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments concrete, neavyweignt 411 s.ou ZU u.au nia u master rune i Sian on uraae Concrete, Heavyweight 518320 Duct Thermostat 28 0.98 n/a pump, etc.) (AFUE/HSPF)(ducts/attic, 2 Guest Suite & Office / Slab on Grade Concrete, Heavyweight 331 3.50 28 0.98 n/a Ducts in Attic 0 Guest Suite &Office /Slab on Grade Concrete, Heayywei h� 1,043 3.50 28 0.98 n/a Ducts in Attic 0 Living/Dining/Entry / Slab on Grade HVAC -2 Central Furnace PERIMETER LOSSES Ducts in Attic 4.2 Setback HVAC -3 Central Furnace 80%AFUE Ducts in Attic 4.2 F2 Insulation _ • Hydronic Piping Type Length Factor R -Val. Depth Location / Comments Pipe S ab Perimeter 46 0.76 0.0 0 Master Suite System Name Length Diameter Thick. Slab Perimeter 33 0.76 0.0 0 Master Suite Minimum Duct Slab Perimeter 65 0.76 0.0 0 Guest Suite &Office Location Duct Thermostat Slab Perimeter 34 0.76 0.0 0 Guest Suite & Office Comments Slab Perimeter 54 0.76 0.0 0 Living/DininglEntry HVAC -1 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -3 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -4 _ • Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -4 WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. AMERICAN CG32-100T88-4N** Large Gas Recirc/Time+Temp 1 88,000 96 0.82 0.0239 0.0 A.O. SMITH FPS -50-224 Small Gas Recirc/Time+Temp 1 43,000 50 0.60 n/a n/a • 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 07/01/04 14:57:56 Run Code: 1088719076 EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page:15 of 42 l A Computer Method Summary (Part 3 of 3) C -2R Ed & Marlies Artzt Residence 0.0 0 7/1/04 Project Tib a 0.76 Da e THERMAL MASS FOR HIGH MASS DESIGN 74 0.76 Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 236 3.50 28 0.98 n/a 2 Kitchen/Family/Nook / Slab on Grade Concrete, Heavyweight 1,140 3.50 28 0.98 n/a 0 Kitchen/Family/Nook /Slab on Grade Concrete, Heavyweight 646 3.50 28 0.98 n/a 2 Casita / Slab on Grade Concrete, Heavyweight 604 3.50 28 0.98 n/a 0 Casita / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 119 0.76 0.0 0 Slab Perimeter 91 0.76 0.0 0 Slab Perimeter 74 0.76 0.0 0 HVAC SYSTEMS Heating Equipment Type (furnace, heat pump, etc.) Central Furnace • H dronic Pi in • Casita Minimum Distribution Type Efficiency and Location (AFUE/HSPF)(ducts/attic, etc.) 80%AFUE Ducts in Attic y p g Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc,) Split Air Conditioner WATER HEATING SYSTEMS Water Heater System Name 13.0 SEER Ducts in Attic Duct Thermostat Location / R -Value Type Comments 4.2 Setback HVAC -5 Duct Thermostat Location / R -Value Type Comments 4.2 Setback HVAC -5 Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Distribution # in Input Cap. or Recovery Standby R -Value Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 07/01/0414:57:56 Run Code: 1088719076 EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Pam: 16 of 42 • Computer Method Summary (Addendum) C -2R & Marlies Artzt Residence 7/1104 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 479 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C-211) - Verify Thermal Mass: 417 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 518 sqft Covered Slab Floor, 3.50" thick at Guest Suite & Office HIGH MASS Design(see C -2R) - Verify Thermal Mass: 331 sqft Exposed Slab Floor, 3.50" thick at Guest Suite & Office The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1043 sqft Exposed Slab Floor, 3.50" thick at Living/Dining/Entry The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the Held venfication and diagnostic testing of these measures on a form CF -6R. an I,.ield The HVAC System - includes Retrigerant Charge and Airflow Credit (ora certitied HEKS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit or a TXV). A certified HERS rater must provid verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAG System includes Refrigerant Charge and Airtlow Credit (ora certnieCl HERS-r-al-er--mu-sTprovide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System includes Retrigerant Charge and Airflow, Credit (ora certified HERS rater—m—u-sT-provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run InitiationTime: un Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:17 of 42 Computer Method Summary (Addendum) C -2R •Ed & Marlies Artzt Residence 7/1/04 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies YGJCu VII I IC aucyual Y VI u1C *F= 0 JU*L lW01. u11 allu uWVUJOIC111OUV11 Duu111111Cu. Plan I Field HIGH MASS Design(see C-211) - Verify Thermal Mass: 236 sqft Covered Slab Floor, 3.50" thick at Kitchen/Family/Nook HIGH MASS Design(see C-211) - Verify Thermal Mass: 1140 sqft Exposed Slab Floor, 3.50" thick at Kitchen/Family/Nook The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -5" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 646 sqft Covered Slab Floor, 3.50" thick at Casita HIGH MASS Design(see C -2R) - Verify Thermal Mass: 604 sqft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Run Initiation Time: un Code: 1088719076 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 18 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Ed & Marlies Artzt Residence 7/1/04 OSYSTEM NAME FLOOR AREA HVAC -1 896 Number of Systems Heating System Output per System Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfmrron) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 26.0 of 69.6 of 69.6 of Outside Air Q 0 cfm 69.6 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 37.9 TOTAL SYSTEM LOAD 316.2 HVAC EQUIPMENT SELE 1,200 1,200 CARRIER 38HDC036 1.34 Supply Fan Heating Coil 1200 cfm COIL COOLING PEAK I I COIL HTG. PEAK CFM ISensiblel Latent11 CFM I Sensible 515 9,884 0 226 9,999 0 494 500 0 0 0 0 0 0 0 0 0 494 500 Total Adjusted System Output 24,024 4,688 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm �% Return Air Ducts 4 res 11.0/77.6 OF 74.4/61.5 OF 74.4/61.5 OF = 55.6/54.5 OF Outside 0 cfm 74.4/61.5 of Supply Fan Cooling Coil 1200 cfm 10,999 54,000 54,000 Jan 12 am Supply Air Ducts 111.5 of ROOMS 70.0 of Supply Air Ducts 56.0 154.7 of 49.0% R.H. ROOMS 74.0/61.4 of Return Air Ducts I EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page 19 of 42 � 0 IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Ed & Marlies Artzt Residence 7/1_/0.4 SYSTEM NAME FLOOR AREA HVAC -2 849 Number of Systems 1 Heating System Output per System 54,000 Total Output (Btuh) 54,000 Output(Btuh/sgft) 63.6 Cooling System Output per System 29,400 Total Output (Btuh) 29,400 Total Output (Tons) 2.5 Total Output (Btuh/sqft) 34.6 Total Output (sgftrron) 346.5 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.18 Airflow (cfmrron) 408.2 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF 69.4 of Outside Air Q 0 cfm Supply Fan 1000 cfm 69.4 OF 111.0 / 77.6 OF Outside Air 0 cfm 74.5/60.1 °F E 1 E 69.4 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK1 CFM I Sensible Latent I I CFM I Sensible 490 10,704 0 0 236 12,464 623 0i 535 0 0 0 0 0 tl 0 0 623 535 11,7740 13,7101 CARRIER 38HDC030 22,925 1,367 54,000 Total Adjusted System Output 22,925 1,367 54,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am, 120.2 OF Heating Coil S, Return Air Ducts 4 74.5/60.1 OF 74.5/60.1 OF 53.0/51.8 OF --1112/ Supply Fan 1000 cfm Cooling Coil S, Return Air Ducts q EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Supply Air Ducts 119.6 OF ROOMS 70.0 OF Supply Air Ducts I i 53.5 / 52.0 of 44.0.1. R.H. ROOMS 74.0 / 59.9 of Page: 20 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY •PROJECT NAME DATE Ed & Marlies Artzt Residence 7/1/04 SYSTEM NAME FLOOR AREA HVAC -3 1,043 Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sqft) 85.3 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 55.6 Total Output (sgWron) 215.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.92 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of Outside Ai 0 cfm 69.7 OF 11.0 / 77.6 of Outside Air 0 cfm •174.4 / 61.0 of E!� 69.7 of 69.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 80 16,163 0 322 14,107 0 808 705 0 0 0 0 0 0 0 0 0 808 705 17,779 0 15,518 HVAC EQUIPMENT SELECTION CARRIER 38HDC060 41,957 6,633 89,000 Total Adjusted System Output 41,957 6,633 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 2 pm an 12 am earn Temperatures at Time of Heating ea 111.5 of - - S I M Duct Supply Fan Heating Coil 2000 cfm KUML I KILN (Airstream I em 74.4/61.0OF 74.4/61.OoF m Supply Fan 2000 cfm AReturn Air Ducts 4F ra ures a Time o Cooling 54.7/53.6OF Cooling Coil � Return Air Ducts q upp y it s 111.2 of ROOMS 70.0 of Supply Air Ducts 55.0 / 53.7 of 47.2% R.H. ROOMS 74.0 / 60.9 of EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:21 of 42 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE is Ed & Marlies Artzt Residence 7/1/04 SYSTEM NAME FLOOR AREA HVAC -4 1,376 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sqft) 64.7 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 42.2 Total Output (sgft/Ton) 284.7 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.45 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD -IVAC EQUIPMENT SELE COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 852 17,139 0 458 19,945 0 857 997 0 0 0 0 0 0 0 0 0 857 997 I 18,853 0 1 21,939 CARRIER 38HDC060 41,969 6,633 89,000 Note: values above given at ARI conditions I L F-ATING SYSTEM PSYCH ROM ETRIGS ICS rea Total Adjusted System Output 41,969 6,633 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm an 12 am empera ures at Time—Mre—af—ing ea 26.0 OF 69.5 OF 69.5 OF 111.30F Outside Air Q 0 cfm Supply Fan Heating Coil 2000 cfm 69.5 OF 11.0 / 77.6 OF Outside A 0 cfm • 74.4/61.0 °F �, Return Air Ducts V KUMC I KlUb (Airstream I emperatures at I Ime 74.4/61.0 OF 74.4/61.0 OF 54.7/53.6 OF Supply Fan Cooling Coil 2000 cfm EnergyPro 3.1 By EnergySoft User Number: 5533 Return Air Ducts Job Number: Supply Air Ducts 110.9 OF ROOMS 70.0 OF I Supply Air Ducts 55.1 /53.8 OF 47.2% R.H. ROOMS 74.0 / 60.9 OF Page:22 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE 0 Ed & Marlies Artzt Residence 7/1/04 SYSTEM NAME FLOOR AREA HVAC -5 1,250 • Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sgft) 56.8 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 37.6 Total Output (sgft/Ton) 319.1 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.28 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 69.5 OF 11.0 / 77.6 of OutsideA 0 cfm •I 74.4/60.9 of 69.5 of 69.5 OF -(T)-" Supply Fan 1600 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent 1, CFM I Sensible 688 13,976 0 423 18,274 0 699 914 0 0 0 0 0 0 0 0 0 699 914 15,374 20,101 CARRIER 38HDC048 33,881 5,446 71,000 Total Adjusted System Output 33,881 5,446 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm an 12 am Heating Coil k Return Air Ducts V 74.4 / 60.9 of 74.4 / 60.9 OF ■ 54.5 / 53.4 OF O , /1 Supply Fan 1600 cfm Cooling Coil �, Return Air Ducts %4 Supply Air Ducts 110.6 of ROOMS] 70.0 OF Supply Air Ducts 54.9 / 53.6 of 46.9% R.H. ROOMS 74.0 160.8 of EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 23 of 42 1 41 ROOM LOAD SUMMARY PROJECT NAME Ed & Marlies Artzt Residence DATE 7/1/04 SYSTEM NAME HVAC -1 FLOOR AREA 896 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite as er Suite 1 515 9,884 0 515 9,884 0 226 9,999 PAGE TOTAL 1 515 9,884 0 226 9,999 ' TOTAL 515 9,884 0 226 9,999 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:24 of 42 C 0 ROOM LOAD SUMMARY PROJECT NAME Ed & Marlies Artzt Residence DATE 7/1/04 SYSTEM NAME HVAC -2 FLOOR AREA 849 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult..CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Suite & Office ues ui a ice 1 490 10,704 0 490 10,704 0 236 12,464 PAGE TOTAL 490 10,704 0 236 12,464 TOTAL 1 490 10,704 0 236 12,464 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:25 of 42 Is • ROOM LOAD SUMMARY PROJECT NAME 'Ed & Marlies Artzt Residence DATE 7/1/04 SYSTEM NAME HVAC -3 FLOOR AREA 1,043 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living/Dining/Entry wing ening n ry 1 801 16,163 0 801 16,163 0 322 14,107 PAGE TOTAL 801 16,163 0 322 14,107 TOTAL 801 16,163 0 322 14,107 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:26 o 42 • • ROOM LOAD SUMMARY PROJECT NAME Ed & Marlies Artzt Residence DATE 7/1/04 SYSTEM NAME HVAC -4 FLOOR AREA 1,376 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Kitchen/Family/Nook i c en ami y o0 1 852 17,139 0 852 17,139 0 458 19,945 PAGE TOTAL 852 17,139 458 19,945 TOTAL 1 852 17,139 0 458 19,945 I'I EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:27 of 42 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:28 of 42 PROJECT NAME Ed & Marlies Artzt Residence DATE 7/1/04 STEM NAME HVAC -5 FLOOR AREA 1,250 [ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita asi a 1 688 13,976 0 688 13,976 0 423 18,274 • I� f • PAGE TOTAL 688 13,976 0 423 18,274 TOTAL 688 13,976 0 423 18,274 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:28 of 42 ROOM HEATING PEAK LOADS Project Title Date iEd & Marlies Artzt Residence 7/1/04 Room Information Design Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 8% Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction R-38 Roof (11.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted • Area x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x U -Value x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x AT of = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 896.0 0.0280 44.0 1,104 798.0 0.0592 44.0 2,079 56.5 0.5400 44.0 1,342 37.5 0.6000 44.0 990 40.0 0.5500 44.0 968 perimeter = 79.0 44.5 3,516 E -- Items shown with an asterisk l -I aenote conauction through an interior surface to another room. Page Total: 9,999 y Infiltration:I 1.00 x 1.064 x 896 x 11.20 x 0.00 / 6G1 x L c e u e it Sensible Area Celling Height —i pT Fraction 01 TOTAL HOURLY HEAT LOSS FOR ROOM 9,999 EnergyPro 3.1 By EnergySoft User Number: 5533' Job Number: Page: 29 of 42 ROOM HEATING PEAK LOADS Project Title Date BEd & Marlies Artzt Residence 7/1/04 Room Information Design Conditions Room Name Guest Suite&Office Time of Peak Jan 12 am Floor Area 849 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr IR -38 Roof (R.38.2x14.16) IR -21 Wall (1.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Slab -On -Grade Cj 849.0 X X X x X x x x X x x X X x X X x x x x X X X X X X X x X X X X X x x x X x x 0.0280 x X X x X x x x X X X X x x X X X X X X X X x x X X X x x x x X X X X X X X X 44.0 = = = = = = = = = = = = = = = = = = = = c = = = = = = = = = = 1,046 933.0 0.0592 44.0 2,431 84.0 0.6000 44.0 2,218 80.0 0.5500 44.0 1,936 18.0 0.5400 44.0 428 perimeter = 99.0 44.5 4,406 I—% I..' ,. 1-1- Page Total: I 12,464] Infiltration: I 1.00 x 1.064 x 849 x 10.00 x 0.00 / 60� x c e u e Air ensi a Area Ceiling Height A pT Fraction • TOTAL HOURLY HEAT LOSS FOR ROOM 12,464 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 30 of 42 ROOM HEATING PEAK LOADS Project Title Date Ed & Marlies Artzt Residence 7/1/04 Room Information Design Conditions Room Name Living/DininglEntry Time of Peak Jan 12 am Floor Area 1,043 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction C] R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Area X X X X X x X x X X x x X X X X X X x x x X x x X X x X X X X X x X x x x X X U -Value x X X X X X x x X x x X x X x X X X X X X X X x x X X X X x X X X X X X X x x AT of = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 1,043.0 0.0280 44.0 1,285 810.2 0.0592 44.0 2,111 209.8 0.5500 44.0 5,077 136.0 0.5400 44.0 3,231 perimeter = 54.0 44.5 2,403 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 1 14,107 Infiltration: I 1.00 x 1.064 x 1,043 x 19.00 x 0.00 /6 x L the u e Air bensible Area teii—ng eight pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,107 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 31 of 42 ROOM HEATING PEAK LOADS Project Title Date BEd & Marlies Artzt Residence 17/1/04 Room Information Design Conditions Room Name Kitchen/Family/Nook Time of Peak Jan 12 am Floor Area 1,376 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr R-30 Roof(R.30.2x4.24) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Solid Wood Door Slab -On -Grade 1,376.0 X x x x X X x x X X x X x X x x X x x X x x x x x X X X x X x x X x x x X x X 0.0306 X x x x X x X x X X X X X X x X X X X x x x x x X x x X X x X X x X X X X x x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,851 1,335.1 0.0592 44.0 3,478 113.6 0.6000 44.0 2,999 120.0 0.5500 44.0 2,904 48.0 0.5400 44.0 1,140 21.3 0.3872 44.0 363 perimeter 162.0 44.5 7,209 Items shown with an asterisk (-r) denote conduction through an interior sunace to another room. Page Total: 19,945 Infiltration: I 1.00 x 1.064 x 1,376 x g11.75 x 0.00 /6 x _ Sc e u e Air Sensible Area ei in ei t Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,945 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 32 of 42 ROOM HEATING PEAK LOADS Project Title Date BEd & Marlies Artzt Residence 7/1104 Room Information Design Conditions. Room Name Casital Time of Peak Jan 12 am Floor Area 1,250 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Slab -On -Grade • Area x x X x X X X x x X x x X x x x X x x x X X X x X X X X X X x X X x x x x x X U -Value X X X X X X x x X x X x X X x X x X X X X X X X X X x X X x x x X X X X x X X AT of = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 1,250.0 0.0280 44.0 1,540 1,368.0 0.0592 44.0 3,564 106.0 0.6000 44.0 2,798 80.0 0.5500 44.0 1,936 46.0 0.5400 44.0 1,093 perimeter= 165.0 44.5 7,342 Mems shown with an astensK (-r) genote conduction tnrougn an interior surtace to another room. Page Total: 18,274 Infiltration: I 1.00 x 1.064 x 1,250 x 10.00 x 0.00 160 x Sc e u e it ensi a Area Celling Height Ac pT Fraction • TOTAL HOURLY HEAT LOSS FOR ROOM 18,274 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 33 of 42 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Ed & Marlies Artzt Residence 7/1/04 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 740F 112°F 380F Conduction Area U -Value DETD 1 Btulhr R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted 37 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. X X X X X X X X 0.0280 0.0592 0.5400 0.6000 0.5500 X X X X X 55.0 = = = = = 1,380 34.6 1,635 38.0 1,159 38.0 855 38.0 836 Page Total 5,865 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (North) Window (North) Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) Window (South) ( 0.0X A ( 0.0 X X X X X X x x 1 + + + + + + + + + + 12.0 X X X X X X x x ( 0.0 1 12.5 ( 0.0 1 12.5 ( 0.0 1 12.5 (-0.0 1 16.0 ( 0.0X A 20.6X ( 0.0X 1 20.0X (-0.0 1 16.0 (-0.0 1 12.5 ( 15)X X X X X X ) X )X 0.512 = = = = = = = = _ = 92 15)X 0.512 96 73) 0.512 467 73) 0.512 467 73)X 0.512 598 73) 0.512 748 73) 0.512 748 73) 0.512 598 3 0.512 205 Sched. Page Total 4,019 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 896 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 x 896 x 255 Btuhlocc. / 0 sgftlocc. = 0 Receptacle 1.00 X 896 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0 Process 1.00 x 896 x 0.000 Watts/sqft X 3.41 Btuh[Watt = 0 Infiltration:Ccl��e-d. X 1.064 X 896 x g 11920 X 0.00 60] 38 = it Sense a Area eilm e� Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,884 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 896 X 225 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 x 896 x 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Process 1.00 x 896 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: [ 1.00 x 4,77 X 89 x 11.20 X 0.00 / 60] Sc rf-edu a Aii Lam rea ceding eig AC pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page: 34 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY .Ed & Marlies Artzt Residence 7/1/04 Project Title Date Room Name Guest Suite & Office C. • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 740F 112°F 38OF Conduction Area U -Value DETD' Btu/hr X X X X X X X x X X (North) 55.0 = 1,308 X Window 34.6 = 1,911 X (North) 38.0 = 1,915 X Window 38.0 = 1,672 X 0.512 38.0 = 369 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 7,176 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (North) Window (North) Window (North) Window (North) Window (North) Window (North) Window (South) Window (South) Window (South) Window (West) 0.0 x1 X x X+ XrA,+ xX X x x x + + + + + + + 6.0 X X X X X X x X x 15)X X 0.512 = = = = = = = = __ = 46 0.0 1 10.0 15)x 0.512 77 0.0 1 10.0 15)x 0.512 77 0.0 20.0 15)x 0.512 154 0.0 20.0 -15)x 0.512 154 0.0 15)X 0.512 46 10.0 1 Al 0.0 32) 0.512 77 0.0 20.0 -32)X 0.512 328 0.0 1 20.0 32)X 0.512 328 0.0 1 18.0 73)x 0.512 673 Sched. Page Total 1,958 Internal Gain Frac. Area Heat Gain Btulhr Lights 1.00 X 849 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 X 849 x 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 849 X 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 Process 1.00 x 849 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: 1.00 x 1.064 X 849 X _ g 1 90o x 0.00 / 60] 0 38 = 01 cfieau a Air 5ensi a Area eih'n Rei -h C Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,704 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 849 x 225 Btuhlocc. lA341 sgft/occ. = 0 Receptacle 1.00 X 849 x 0.000 Watts/sqft XBtuh/Waft = o Process 1.00 x 84s x 0.000 Watts/sgft xBtuh/Watt = 0 Infiltration: [ _ 1.00 x 4,771 x 849 X 10.00 x 0.00 / 60] 0.00000 = 0 Sc e u e lZatenf ' AreaImg egg c pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 35 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY is Ed & Marlies Artzt Residence 7/1/04 Project Title Date • 11 11 u Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suite & Office 740F 112°F K:�l Conduction Area U -Value DETD 1 Btu/hr X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window Window Window Page Total SC Btu/hr (West) ( 0.0 x x x x x x x x x x 1 + + + + + + + + + + 18.0 x x x x x x x x x x 73) x x )x )x )x )x )x )x )x 0.512 = = = = = = = = = = 673 (Vilest) ( 0.0 1 18.0 -73)x 0.512 673 (West) ( 0.0 1 6.0 73) 0.512 224 ( ( ( ( ( ( ( Scheid. Page Total 1 1,570 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 849 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Occupants 1.00 x 849 x 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 x 849 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 849 x 0.000 Wafts/sqft x 3.412 Btuh[Watt = 0 Infiltration:1.00 x 1.064 x 849 x 10.00 x 0.o0 / 60 ] 38 = Ce u e AirSense a Area eimg HeightICC p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,704 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 849 x 225 Btuh/OCC. / 0 sgft/occ. = 0 Receptacle 1.00 x 849 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 849 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: [ _ 1.00 x 4,77 x �84�g x 10.00 x 0.00 / 60] 0.00000 = 0 Schedu a Air La eE—n rea Ceilm" g =.,,oi Ac pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page: 36 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Ed & Marlies Artzt Residence 7/1/04 Project Title Date Room Name Living/Dining/Entry Design Indoor Dry Bulb Temperature: 74°F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 38OF Conduction Area U -Value DETDBtu/hr • X X X X X X X X X 55.0 = = = = = = = = = 1,606 34.6 1,660 38.0 4,385 38.0 2,791 Window (East) Window (East) Window (East) Window (East) Window (East) 1. Design Equivalent Temperature Difference (DETD) Page Total 10,442 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) 19.8 X X X X x x Al + + +0.2X + + + + + + + 0.2 X X x x X x 73)x X 0.512 = = = = = 161 19.8x 0.2x 73)x 0.512= 161 19.8X 1 73)X 0.512= 161 19.8X 1 0.2x 73)x 0.512= 161 19.8x 1 0.2x 73)x 0.512= 161 19.8 1 0.2 73)X 0.512 161 19.8 1 0.2 73)X 0.512 161 19.8 1 0.2 73)X 0.512 161 0.0 1 5.0 73) 0.512- 187 0.0 1 5.0 73)X, 0.512 187 Sched. Page Total 1,ssz Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,043 x 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 Occupants 1.00 x 1,043 x 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 1,043 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,043 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: [ _ 1.00 x _ 1.064 x 1,043 x , ^ 19.00 x 0.00 / 60] 38 = l� Sc r15e a Air Sensible Area e� Ing eig ACH pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,163 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,043 x 225 Btuh/OCC. / 0 sqft/occ. = 0 Receptacle 1.00 x 1,043 X 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 1,043 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: [ _ 1.00 x 4,77 x 1,043 x 19.00 x 0.00 / 60] Schede a i� t_aten Area Ceiling eig AC pw Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By Energysott User Number: 5533 Job Number: Page: 37 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Ed & Marlies Artzt Residence 7/1/04 Project Title Date Room Name Living/Dining/Entry • • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 740F 112°F 380E Conduction Area U -Value DETD 1 Btu/hr X = X = X = X = X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total L Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr Window (East) Window (East) Window (West) Window (West) Window (West) Window (West) Window (West) Window (West) Window (West) Window (West) 0.0x)X x x x X x x+ x + + + + + + + + x X x x x x X x X 0.512= = = = = = _ = 187 0.0 1 Al 5.0 73) 0.512 187 28.2 1 19.8 73) 0.512 957 14.1 10.8 73)x 0.512 512 14.1 1 10.8 73)x 0.512 512 28.2 1 19.8 -73)X 0.512 957 0.0x 1 5.0x 73)x 0.512= 187 0.0xA111 5.0X 73)x 0.512= 187 0.0 5.0 -73)x 0.512 187 o.O 1 5.0 -73)x 0.512 187 Sched. Page Total a,o59 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,043 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 x 1,043 X 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 1,043 x 0.000 Watts/sgft X 3.413 Btuh/Watt - 0 Process r 1.00 x 1,043 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: I 1.00 x 1.064 x 1,043 x g 1 900 x 0.00 /60 -sche�Jr u e Air 5ensi a Area edm ei C Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,163 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1,043 x 225 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 1,043 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 1,043 X 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Infiltration:[ 1.00 X 4,771 x 1,043 x _ 19.00 x 0.00 / 60] 0.00000 = E:=0 Schede a Air Latent Area Ceiling eig Al pw Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 38 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Ed & Marlies Artzt Residence 7/1/04 Project Title Date Room Name Kitchen/Family/Nook Design Indoor Dry Bulb Temperature: 74°F Design Outdoor Dry Bulb Temperature: 112°F Design Temperature Difference: 38°F • • Conduction Area U -Value DETD 1 R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Solid Wood Door 1,335. 113. 21 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF Window (North) Window (North) Window (North) Window (North) Window (North) Window (North) Window (East) Window (East) Window (East) Window (East) X 55.0 X 34.6 X 38.0 X 38.0 X 38.0 X 34.6 X X X Page Total Btu/hr 2,314 2,735 2,590 2,508 985 285 11,417 Unshaded Area SGF SC Btu/hr . 0.0 x x x x X X X A11- + + + + + + + + + + 12.5 X X X X X x X 15)X x X X x 0.512 = = = = = _ = 96 0.0 12.5 15)x 0.512 96 0.0 1 20.0 15)x 0.512 154 0.0X 1 20.0x 15)x 0.512= 154 0.0x 1 10.0x 15)x 0.512= 77 0.0x 1 10.0X 15)x 0.512= 77 0.0 1 24.0 73) 0.512 897 0.0 1 20.0 73) 0.512 748 0.0 1 20.0 73) 0.512 748 0.0 1 24.0 73) 0.512 897 Sched. Page Total 3,943 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,376 x 0.000 Wafts/sqft X 3.41 Btuh/Watt = 0 Occupants 1.00 X 1,376 x 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 1,376 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 X 1,376 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: 1.00 x 1.064 x 1,376 X 9 11975 x 0.00 / 66] Q 38 = �� Leffied-. a Sensi a rea ei if n �iJ ACA Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,139 Sched. Latent Gain Frac. Area Heat Gain Btulhr Occupants 1.00 X 1,376 x 0 Btuh/occ. / 20,000 sqft/occ. = 0 Receptacle 1.00 X 1,376 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 1,376 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 x 4,77 x 1,37 x 11.75 x 0.00 / 60] 0.00000 = 0 Sc e 'u e it a en rea CeiUng erg AC pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 39 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Ed & Marlies Artzt Residence 7/1/04 Project Title Date • l 1I I Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Kitchen/Family/Nook 740F 112°F 380E Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window (South) Window (South) Window (South) Window (South) Window (South) Window (South) Window (South) Window (South) 246 0.0 1 20.0 Page Total 0 SC Btu/hr 0.0 x X x X X x x+ X 1 + + + + + + + + + 15.0 X X X X X x X X 32)X x X x X X )x )X 0.512 = = = = = = = = 246 0.0 1 15.0 32) 0.512 246 0.0 1 20.0 32) 0.512 328 0.0 1 20.0 32) 0.512 328 0.0 1 11.3 32) 0.512 185 0.0 1 11.3 32) 0.512 185 0.0X 1 8.0X 32)x 0.512= 131 0.0x 1 8.0X 32)X 0.512= 131 Sched. Page Total 1,780 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,376 X 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 Occupants 1.00 X 1,376 X 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 1,376 x 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Process 1.00 X 1,376 X 0.000 Watts/sgft x 3.41 Btuh[Watt = o Infiltration:1.00 x 1.064 x 1,376 x g 11975 x 0.00 /60 e u eSensible L6 Air Area ei m ei Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,139 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,376 x 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 1,376 x 0.000 Watts/sgft x 3.41 BtuhlWatt = 0 Process 1.00 x 1,376 x 0.000 Watts/sgft x 3.413 BtuhfWatt = 0 Infiltration: [ _ 1.00 x 4,771 x 1,37 x 11.75 x 0.00 / 60] 0.00000 = 0 Sche u e Air Latent Area Cei mg eig AC pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page: 40 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Ed & Marlies Artzt Residence 7/1/04 Project Title Date Room Name Casita Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 112°F Design Temperature Difference: 38OF • • Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Area U -Value 1 0.0280 0.0592 0.6000 0.5500 0.5400 DETD 1 Btu/hr X 55.0 = 1,925 X 34.6 = 2,803 X 38.0 = 2,417 X 38.0 = 1,672 X 38.0 = 944 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 9,761 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (North) Window (North) Window (North) Window (North) Window (East) Window (East) Window (East) Window (East) Window (East) Window (East) ( 0.0 x X X x x x X X X 1 + + + + + + + + + 10.0 x x X X x X X X X 15)X X x x x x 0.512 = = = = = = = __ = 77 ( 0.0 1 10.0 15)x 0.512 77 ( 0.0 1 20.0 15) 0.512 154 ( O.Ox 15+ 20.0X 15)x 0.512= 154 ( 0.0 1 10.0 73) 0.512 374 ( 0.0 1 10.0 73)X 0.512 374 ( 15.8 1 4.2 -73)x 0.512 280 ( 15.8 1 4.2 73) 0.512 280 ( 15.8 1 4.2 73) 0.512 280 ( 15.8 1 4.2 73) 0.512 280 Sched. Page Total 2,32a Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,250 x 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 Occupants 1.00 x 1,250 X 0 Btuh/occ. / 20,000 sqft/occ. = 0 Receptacle 1.00 X 1,250 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process Cct��e-ho.o 1.00 x 1,250 X 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: x 1.064 x 1250 x _ g 1900 x 0.00 /6038 Aii 5ensib a rea edin fiei F C Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,976 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,250 x 0 Btuh/occ. / 20,000 sqft/occ. = 0 Receptacle 1.00 x 1,250 x 0.000 Wattslsgft x1 3.413 Btuh/Watt = 0 Process 1.00 x 1,250 x 0.000 Watts/sgft x 1 3.41 Btuh/Watt = 0 Infiltration:[ _ 1.00 x 4,77 x 1,250 x 10.00 x 0.00 / 60] 0.00000 = 0 sc�dule Aii Latent Area Ceil ng e g AC pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 41 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Ed & Marlies Artzt Residence 7/1/04 Project Title Date C] is Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window (South) Window Window (South) (South) Window Window (West) (West) Window (West) Window (West) 77 ( 0.0 1 10.0 32) 0.512 DETD 1 Casita 740F 112°F 38OF Btu/hr Page Total �o SC Btu/hr ( 10.0 X X x+ xEll x X X x x x+ [:715+ + + + + + + + 0.0 X X X x x X x x x x 32)X x X X X )x )X )x 0.512= = = = = = = = = 77 ( 0.0 1 10.0 32) 0.512 164 ( 10.0 0.0 32)x 0.512 77 ( 0.0 15.0 73)X 0.512 561 (-0.0 15.0 73) 0.512 561 ( 0.0 1 6.0 73) 0.512 224 ( 0.0 1 6.0 73) 0.512 224 ( ( ( Sched. Page Total 1,666 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,250 x 0.000 Watts/sgft x 3.41 Btuh[Watt = 0 Occupants 1.00 X 1,250 X 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 1,250 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,250 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 x 1.064 X 1,250 X 10.00 x 0.00 /60 38 = o Schedu a Av SensibleArea eilmg eig ICC p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,976 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,250 x 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 1,250 x 0.000 Watts/sqft x 3.41 BtuhfWatt = 0 Process f 1.00 x 1,250 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: 1.00 x4,77 x 1,250 x g 10.90 x _ o.00 / 60]QoW0000 = 0 the u e it a en Area Ceihn Fri h C Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 42 of 42