Loading...
13-0381 (SFD) Title 240 BUILDING ENERGY ANALYSIS REPORT PROJECT: Clearwater/Sparks Residence 53-540 Del Gato Drive, The Traditions La Quinta, Ca 92253 Project Designer: Fedderly and Associates 38-747 Nopales Road . Palm Desert, Ca 92253 (760) 773-0875 Report Prepared by: Tim Scott Scott Design and Title 24, Inc; 77-085 Michigan Drive Palm Desert, Ca 92211 60) 200-4780 I?ECEIVED CI�OF��QUINTA BUILDING & SAFETY DEPT APPROVED MAY 17 2013 FOR CONSTRUCTION qOM��NIN -p QUIIVTA DATE '2 BY IL. 4� EVEL0pMENT ob Number: Date: 5/15/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712: RunCode: 2013-05-15713:32:46. ID: • 0 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads IEnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 1 2 3 11 14 17 20 24 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family 13 Addition Alone ❑ Multi Family O Existing+ Addition/Alteration Date 5/15/2013 Project Address 53-540 Del Gato Drive, The Traditions La California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,226 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,199 Radiant Barrier New Wall Wood Framed R-21 3,394 New Slab Unheated Slab -on -Grade None 5,226 Perim = 414' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 151.8 0.390 0.39 none none Bug Screen New Rear (NE) 182.5 0.390 0.39 none none Bug Screen New Right (SE) 112.1 0.390 0.39 none none Bug Screen New Front (Stat 189.5 0.390 0.39 none none Bug Screen New Skylight 9.0 0.800 0.39 none none None New Skylight 9.0 0.800 0.39 none none None New Skylight 9.0 0.800 0.39 none none None New Rear (NE) 180.0 0.390 0.39 22.0 none Bug Screen New Rear (NE) 30.6 0.390 0.39 18.0 none Bug Screen New Rear (NE) 90.0 0.390 0.39 14.0 none Bug Screen New Right (S) 160.9 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 8 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Large Gas 65 0.96 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Pa e 3 of 30 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1511512013 Date Project Address 53-540 Del Gato Drive, The Traditions La California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,226 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (K9 61.2 0.390 0.39 none none Bug Screen New Left (NM 74.7 0.390 0.39 none none Bug Screen New Left (NKK 36.0 1.040 0.38 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergrPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Pe e 4 of 30 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The DHW System Lochinvar #SNR126-065 is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 970.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS, Design - Verify Thermal Mass: 324.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 566.0 ft2 Covered Slab Floor, 3.500" thick at Guest 1/ Office HIGH MASS Design - Verify Thermal Mass: 203.0 ft2 Exposed Slab Floor, 3.500" thick at Guest 1/ Office The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 266.0 ft2 Covered Slab Floor, 3.500" thick at GreaWitchen/Dining/Gallery HIGH MASS Design - Verify Thermal Mass: 2,511. 0 ft' Exposed Slab Floor, 3.500" thick at Great/Witchen/Dining/Gallery HIGH MASS Design - Verify Thermal Mass: 327.0 ft2 Covered Slab Floor, 3.500" thick at Guest 2 HIGH MASS Design - Verify Thermal Mass: 59.0 112 Exposed Slab Floor, 3.500" thick at Guest 2 The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA760/58PH•l 10 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA736/58PH'090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH'110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Erre Pro 5.1 by Enem ySoft User Number.- 6712 RunCode: 2013-05-15713:32:46 ID: Page 5 of 30 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Clearwater/Sparks Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/15/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.57 3.02 0.56 Space Cooling 51.52 45.79 5.73 Fans 10.24 14.32 -4.08 Domestic Hot Water 6.98 3.91 3.07 Pumps 0.00 0.00 0.00 Totals 72.31 67.04 5.27 Percent Better Than Standard: 7.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (w) 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (K9 970 251 Fuel Available at Site: Natural Gas (N) 1,245 263 Raised Floor Area: 0 (E) 1,178 483 Slab on Grade Area: 5,226 (S) 1,295 273 Average Ceiling Height: 11.9 Roof 5,226 27 Fenestration Average U -Factor: 0.41 TOTAL: 1.296 Average SHGC: 0.39 Fenestration/CFA Ratio: 24.18% REMARKS 7ot180-The Hideaway STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple Documentation Author Company Scott Design and Title 24, Inc, 5/15/7013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and,recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Associates City/State2jp Palm Desert, Ca 92253 Phone (760) 773-0875 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 6 of 30 • 0 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 15/15/2013 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,294 0.026 R-38 270 0 New 4.2.1-A9 Master Bedroom Wall 219 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 184 0.069 R-21 60 90 New 4.3.1-A6 Master Bedroom Wall 403 0.069 R-21 150 90 New 4.3.1-A6 Master Bedroom Wall 187 0.069 R-21 330 90 New 4.3.1-A6 Master Bedroom Slab 970 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 324 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 769 0.026 R-38 270 0 New 4.2.1 A9 Guest 1/0ffice Wall 229 0.069 R-21 0 90 New 4.3.1-A6 Guest 1/0ffice Wall 55 0.069 R-21 60 90 New 4.3.1-A6 Guest 1/0ffice Wall 44 0.069 R-21 90 90 New 4.3.1-A6 Guest 1/Office Wall 132 0.069 R-21 150 90 New 4.3.1-A6 Guest 1/Office Wall 221 0.069 R-21 240 90 New 4.3.1-A6 Guest 1/Office Wall 215 0.069 R-21 330 90 New 4.3.1-A6 Guest 1/Office Slab 566 0.730 None 0 180 New 4.4.7-A1 Guest 1/Office Slab 203 0.730 None 0 180 New 4.4.7-A1 IGuest 1/Office FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 37.8 0.390 NFRC 0.39 NFRC 0 New Dual non Metal Tinted Master Bedroom 2 Window 24.0 0.390 NFRC 0.39 NFRC 0 New Dual non Metal Tinted Master Bedroom 3 Window 4.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 4 Window 88.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 5 Window 3.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 6 Window 3.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 7 Window 3.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 8 Window 30.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 9 Window 15.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Master Bedroom 10 Window 30.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Master Bedroom 11 Window 4.0 0.390 NFRC 0.39 NFRC 0 New Dual non Metal Tinted Guest 1/0ffice 12 Window 64.0 0.390 NFRC 0.39 NFRC 0 New. Dual non Metal Tinted Guest 1/Office 13 Window 31.5 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/0f ice 14 Window 27.0 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 15 Window 31.5 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 16 Window 4.0 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat I Wd Ove hanq Left Fin Len Hat LExt RExt Dist Len Ri ht Fin Hat Dist Len Hat 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 18ug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Pae 7 of 30 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5L__ CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone [3 Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 2,750 0.026 R-38 270 0 New 4.2.1-A9 Living Zone Wall 78 0.069 R-21 0 90 New 4.3.1-A6 Living Zone Wall 346 0.069 R-21 60 90 New 4.3.1-A6 Living Zone Wall 175 0.069 R-21 150 90 New .4.3. I -A6 Living Zone Wall 110 0.069 R-21 180 90 New 4.3.1-A6 Living Zone Door 24 0.500 None 180 90 New 4.5.1-A4 Living Zone Wall 77 0.069 1 R-21 240 90 New 4.3.1-A6 Living Zone Wall 202 0.069 R-21 270 90 New 4.3.1-A6 Living Zone Wall 54 0.069 R-21 330 90 New 4.3.1-A6 Living Zone Slab 266 0.730 None 1 0 180 New 4.4.7-A1 Living Zone Slab 2,511 0.730 None 1 01 180 1 New 4.4.7-A1 Living Zone Roof 386 0.026 R-38 270 0 New 4.2.1-A9 Guest 2 Wall 64 0.069 R-21 90 90 New 4.3.1-A6 Guest 2 Wall 1781 0.069 1 R-21 180 90 New 4.3.1-A6 Guest 2 Wall 220 0.069 R-21 270 90 New 4.3.1-A6 Guest 2 Slab 3271 0.730 None I 1 0 180 1 New 4.4.7-A1 I Guest 2 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 18 Skylight 9.0 0.800 NFRC 0.39 NFRC 270 New Skylight Living Zone 19 Skylight 9.0 0.800 NFRC 0.39 NFRC 270 New Skylight Livin Zone 20 Skylight 9.0 0.800 NFRC 0.39 NFRC 270 New Skylight Living Zone 21 Window 22.0 0.390 NFRC 0.39 NFRC 0 New Dual non Metal Tinted Living Zone 22 Window 180.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Living Zone 23 Window 30.6 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Living Zone 24 Window 90.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Living Zone 25 Window 45.5 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Living Zone 26 Window 3.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Living Zone 27 Window 3.0 0.390 NFRC 0.39 NFRC 60 New Dual non Metal Tinted Living Zone 28 Window 35.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone 29 Window 23.1 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone 30 Window 3.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone 31 Window 3.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone 32 Window 1 3.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len Hot LExt I RExt Dist I Len Ri ht Fin Hot Dist Len Hot 17 Bug Screen 0.76 18 None 1.00 19 None 1.00 20 None 1.00 21 Bug Screen 0.76 22 Bug Screen 0.76 10.0 18.0 22.0 0.1 22.0 22.0 23 Bug Screen 0.76 6.5 4.7 18.0 0.1 18.0 18.0 24 Bug Screen 0.76 10.0 9.0 14.0 0.1 14.0 14.0 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Peg e 8 of 30 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511512013 OPAQUE SURFACE DETAILS Surface Ll- Type Area Factor Insulation Joint Appendix Cavity Exterior I Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Slab 59 0.730 None 0 180 New 4.4.7-A1 Guest 2 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 90.0 0.390 NFRC 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 34 Window 2.3 0.390 NFRC 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 35 Window 2.3 0.390 NFRC 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 36 Window 2.3 0.390 NFRC 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 37 Window 85.5 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Living Zone 38 Window 3.0 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Living Zone 39 Window 3.0 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Living Zone 40 Window 61.2 0.390 NFRC 0.39 NFRC 270 New Dual non Metal Tinted Living Zone 41 Window 31.5 0.390 NFRC 0.39 NFRC 330 New Dual non Metal Tinted Living Zone 42 Window 36.0 1.040 NFRC 0.38 NFRC 330 New Custom Door Living Zone 43 Window 43.2 0.390 NFRC 0.39 NFRC 330 New Dual non Metal Tinted Living Zone 44 Window 64.0 0.390 NFRC 0.39 NFRC 180 New Dual non Metal Tinted Guest 2 (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC -Hat Wd Ove hanq Left Fin Len Hat LExt I RExt Dist Len Ri ht Fin Hat Dist Len Hat 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05.15713:32:46 ID: Page 9 of 30 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511512013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina I Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,294 16,304 HVAC 2 Guest 1/ Office 769 8,151 HVAC 3 & 4 GreatXitchen/Dining/Gallery 2,777 33,602 Guest 2 386 4,246 Totals 5,2261 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Coolina Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE S lit Air Conditioner 16.5 SEER Setback New HVAC 3 & 4 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New WATER HEATING SYSTEMS S stem Name Oty. Ty e Distribution Rated Input (Btu h) Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Lochinvar#SNR126-065 1 Large Gas All Pipes Ins 126,000 65 0.96 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o y a c System Name Pipe Length Pipe Diameter Insul. Thick. QtyTHP Plenum Outside Buried EnerqyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-05-15713:32:46 ID: Pae 10 of 30 • 0 • MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name Clearwater/Sparks Residence Date 5/15/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. ` §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the ' installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. §150(q): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance -rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is `-equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the ,outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. ,1§150(h): _§1500): Heatingsystems are equipped with thermostats that meet the setback requirements of Section 112(c). �,§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped "with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water &`tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. '§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. - 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. �. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 11 of 30 0 • • MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Clearwater/Sparks Residence 1511512013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the -applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air -Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation ,required in Section 4 of that Standard. Pool and S a Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). "§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. -•§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 12 of 30 0 • • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Clearwater/Sparks Residence 5/15/2013 ,§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on .occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more -dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that ..they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion .sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided .'that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 13 of 30 C� • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Clearwater/Sparks Residence Date 5/15/2013 System Name HVAC 1 Floor Area 1,294 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 815 18,261 Return Vented Lighting 0 Return Air Ducts 1,054 Return Fan 0 Ventilation F 0 0 Supply Fan 0 Supply Air Ducts 1,054 TOTAL SYSTEM LOAD 20,369 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 110,000 1,008 280 15,167 Total Output Btuh 110,000 Output Btuh/s ft 85.0 745 Cooling System 0 Output perSystem 59,000 0 0 0 Total Output Btuh 59,000 1,008 0 Total Output ons 4.9 745 Total Output Btuh/s ft 45.6 Total Output s ft/Ton 263.2 16,658 'Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24APA760/58PH'110 46,928 Total Adjusted System Output 46,928 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,133 110,000 4,133 110,000 Aug 3 PM F Jan 1 AM Alrflow cfm/s ft 1.55 Airflow cfm/Ton 406.8 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF �. Outside Air 0 cfm Supply Fan 2,000 cfrn 70 OF 70 OF 121 OF 10 10 Heating Coil 121 OF FROOM r 70 OF -COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78!63°F Outside Air 0 cfm 78/63°F 78/63°F 56/55°F Supply I Fan Cooling Coil57 / 55 OF 2,000 cfm _-..-............ .— 44.2% ROOM 78/63°F r EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-05-15713:32:46 ID: Page 14 of 30 • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Clearwater/Sparks Residence Date 5/15/2013 System Name HVAC 2 Floor Area 769 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 374 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Outout oerS stem 89,000 9,105 680 152 11,150 Total Output Btuh 89,000 0 Output Btuh/ ft 115.7 526 548 `Cooling System 0 0 Output perSystem 36,600 0 0 0 0 Total Output Btuh 36,600 0 526 1 10,157 680 0 Total Output ons 3.1 548 Total Output Btuh/s ft 47.6 Total Output s ft/Ton 252.1 12,246 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ACA736/58PH•090 30,261 941 89,000 Airflow cfm/s ft 1.56 Total Adjusted System Output 30,261 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 941 1 89,000 Aug 3 PM F Jan 1 AM Airflow cfm/Ton 393.4 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 elm Supply Fan 1,200 cfm 70 OF 70 OF 139 OF Heating Coil 138 OF ••••••- .. ROOM 70 OF '.COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 78 162 OF 78 / 62 OF 55 / 53 OF o Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,200 cfm 41.3% ROOM 78 162 OF 78 / 62 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 15 of 30 • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Clearwater/Sparks Residence Date 5/15/2013 System Name HVAC 3 & 4 Floor Area 3,163 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,943 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 110,000 43,094 2,375 746 40,266 Total Output Btuh 220,000 0 Output Btuh/ ft 69.6 2,488 1,979 Coolin System 01 0 Output per System 59,000 0 0 0 0 Total Output Btuh 118,000 0 2.486 1 48,069 2,375 0 Total Output ons 9.8 1,979 Total Output Btuh/s ft 37.3 Total Output s ft/Ton 321.7 44,224 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Alrf low cfm 4,000 Carrier 24APA760/58PH'110 93,679 Total Adjusted System Output 93,679 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 8,654 220,000 8,654 220,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 1.26 Airflow cfmfron 406.8 Outside Air°io 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions -HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 4,000 cfm 70 of 70 OF 121 OF Heating Coil 121 OF --- ROOM M 70 OF ,COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 79163 Outside Air 0 cfm 79 / 63 OF OF 79 / 64 OF 57 / 55 OF Supply Fan Cooling Coil57156 OF _...... _ _........... _..._.. a,000 cfm 44.5% ROOM 78 / 63 OF EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 16 of 30 • • • ROOM LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 5/15/2013 System Name Floor Area HVAC 1 1,294 ROOM LOAD SUMMARY ROOM COOLINNPEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM SensibleCFM Sensible Latent • CFM Sensible Master8edroom Master Bedroom 1 815 18,261 8151 18,2611 1,008 2601 15,167 .m 6712 PAGE TOTAL TOTAL' 815 18,261 1,008 280 15,167 815 18,261 1,008 280 15,167 • • ROOM LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 5/15/2013 System Name Floor Area HVAC 2 769 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM I Sensible Guest 1/Office Guest 1/ Office I 1 1 3741 9,1051 680 3741 9,1051 6801 1521 11,150 ' Total i Enemy, PAGE TOTAL TOTAL' 374 9,105 680 1,521 11,150 374 9,105 680 152 11,150 0 • ROOM LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 5/15/2013 System Name Floor Area HVAC 3 & 4 3,163 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM Sensible Living Zone GreatXitchen/Dining/Gall 1 1,770 39,243 1,934 1,770 39,243 1,934 647 34,969 Guest Guest 1 1 1741 3,8511 441 174 3,851 4411 98 5,297 PAGE TOTAL 1,943 43,094 2,375 746 40,266 •TOTAL' 1,943 43,094 2,375 746 40,266 ' Total includes ventilation load for zonal systems. N • • • ROOM HEATING PEAK LOADS Project Name75/15/2013 ate Clearwater/Sparks Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Time of Peak Jan 1 AM Floor Area 1,294.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R.38.2x 12.16) 1,294.0 X 0.0260 X 44 = 1,480 R-21 Wall (W.21.2x6.16) 992.7 X 0.0690 X 44 = 3,014 Dual non Metal Tinted 237.8 X 0.3900 X 44 = 4,081 Slab -On -Grade perm = 107.0 X 0.7300 X 44 = 3,437 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X J= Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 12.012 Infiltration:[ 1.00 X 1.064 X 1,294 X 12.60 X 0.248 /60] X 44 0 3,156 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,167 EneTyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-15T13:32:46 ID: Page 20 of 30 1 • • ROOM HEATING PEAK LOADS Project Name Date Clearwater/Sparks Residence 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest I/ Office Time of Peak Jan 1 AM Floor Area 769.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area R-38 Roof(R.38.2x 12.16) 769.0 R-21 Wall (W.21.2x6.16) 896.0 Dual non Metal Tinted 166.0 Slab -On -Grade perim = 88.0 Items shown with an asterisk (`) denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 769 X Schedule Air Sensible Area Fraction U -Value X 0.0260 AT -F Btu/hr X 44 = 880 X 44 = 2,720 X 44 = 2,849 X 44 = 2,827 X = X = X = X = X = X = X = X = X X = X X X X X X = X = X X X = X X = X X _ X = X X Page Total 9.275 /60] X 44 = 1,875 AT X X X X X X 0.0690 0.3900 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X to another room 10.60 X 0.295 Ceiling Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 11.150 L] • • ROOM HEATING PEAK LOADS Project Name75/15/2013 Clearwater/Sparks Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Dining/Gallery Floor Area 2,777.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R.38.2x 12.16) 2,750.0 X Skylight 27.0 X R-21 Wall (W.21.2x6.16) 1,043.5 X Dual non Metal Tinted 765.5 X Wood Door 24.0 X Custom Door 36.0 X Slab -On -Grade Perim = 175.0 X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 2, 777 X Schedule Air Sensible Area Ceiling Fraction U -Value 0.0260 X 0.6000 X 0.0690 X 0.3900 X 0.5000 X 1.0400 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X L X another room 12.10 X 0.258 Height ACH AT OF Btu/hr 44 = 3,146 44 = = 950 44 3,168 44 = 13,136 44 = 528 44 = = = = 1,647 44 5,621 = = = = = = = = = = = = = = = = = = Page Total /60] X 44 AT 28,197 = 6,772 TOTAL HOURLY HEAT LOSS FOR ROOM 34,969 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 22 of 30 • • • ROOM HEATING PEAK LOADS Project Name ClearwaterlSparks Residence Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 2 Floor Area 386.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 386.0 X 0.0260 X 462.0 X 0.0690 X 64.0 X 0.3900 X pan = 44.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 386 X 11.00 X 0.284 Area Ceiling Height ACH AT °F Btu/hr 44 = 442 44 = 1,403 44 = 1,098 44 = 1,413 = = = = = = = = = = = = = = = = = = = = = = Page Total 4,356 / 60 1 X 44 = 941 AT R-38 Roof(R.38.2x 12.16) R-21 Wall (W.21.2x6.16) Dual non Metal Tinted Slab -On -Grade Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 5,297 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 23 of 30 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,294.0 (tz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces Orientation Area U -Factor X X X X X X X X X CLTD' R-38 Roof(R.38.2x 12.16) (lM 1,294.0 X 0.0260 X 77.0 = R-21 Wall (W.21.2x6.16) (N) 219.2 X 0.0690 X 31.0 = R-21 Wall (W.21.2x6.16) (NE) 184.0 X 0.0690 X 37.3 = R-21 Wall (W.21.2x6.16) (SE) 403.0 X 0.0690 X 41.3 = R-21 Wall (W.21.2x6.16) (NM 186.5 X 0.0690 X 45.8 = (NE) (SE) 0.0 X 30.0 X = 27.1 15.0 X X = X X = X J X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF O 11 N M BB BB BB L K Internal Gain (N) (N) (NE) 0.0 X X X X X X X X X 27.1 + + + + + + + + + 37.8 X X X X X X X X X 27.1 = = = = = = = = = 0.0 27.1 24.0 27.1 0.0 27.1 4.0 48.3 (NE) (NE) (NE) (NE) 0.0 27.1 88.0 48.3 0.0 27.1 3.0 48.3 0.0 27.1 3.0 48.3 0.0 27.1 3.0 48.3 (NE) (SE) 0.0 27.1 30.0 48.3 0.0 27.1 15.0 56.4 Page Total 1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,2001 Btu = I Infiltration: 1.064 X 0.87 X 70.81 X 34 = Air Sensible CFM ELA AT ll Latent Gain Occupants 1.0 Occupants X 200 Btuh/occ. _ Infiltration: 4,771 X 0.87 X 70.81 X 0.00276 = Air Sensible CFM ELA AW Btu/hr 2,591 469 474 1,149 589 2721 Btu/hr 1,024 650 193 4,252 145 145 145 1,450 2,218 18,261 Btu/hr 200 808 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 1 5115/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,294.0 fie Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X X X X X = X X = X X X X X X = X X X X Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10 (SE) 0.0 X 27.1 + 30.0 X 56.4 = 1,691 X + X X + X X + X - X + X - X + X - X + X - X + X - X + I X - Page Total 1,691 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,200 Btu c 0 Infiltration: 1.064 )( 0.87 X 70.81 X 34 = 2,218 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,261 Latent Gain Btu/hr Occupants 1.0 Occupants X F 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 70.81 X 0.00276 = F7778-08 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,008 Ene-myPro, 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Pace 25 of 30 ` f M • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest I/ Office Outdoor Dry Bulb Temperature 112 OF Floor Area 769.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-36 Roof(R.38.2x 12.16) (IM 769.0 X 0.0260 X 56.0 = 1,120 R-21 Wall (W.21.2x6.16) (N) 229.0 X 0.0690 X 23.0 = 363 R-21 Wall (W.21.2x6.16) (NE) 55.0 X 0.0690 X 30.3 = 115 R-21 Wall (W.21.2x6.16) (E) 44.0 X 0.0690 X 33.0 = 100 R-21 Wall (W.21.2x6.16) (SE) 132.0 X 0.0690 X 29.3 = 267 R-21 Wall (W.21.2x6.16) (SIM 221.0 X 0.0690 X 31.7 = 483 R-21 Wall (W.21.2x6.16) (NIM 215.0 X 0.0690 X 29.3 = 435 X X = X J X I= Page Total 2,883 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr P (N) 0.0 X 22.3 + 4.0 X 22.3 = 69 7 (N) 0.0 X 22.3 + 64.0 X 22.3 = 1,425 S (SW) 0.0 X 22.3 + 31.5 X 32.2 = 1,015 12 (SIM 0.0 X 22.3 + 27.0 X 32.2 = 870 S (SW) 0.01 X 22.3 + 31.5 X 32.2 = 1,015 R (SIM 0.0 X 22.3 + 4.0 X 32.2 = 129 Q (SIM 0.0 X 22.3 + 4.0 X 32.2 = 129 X + X - X +1 X - Page Total 4,674 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 42.08 X 34 = 1,318 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,105 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 42.08 X 0.00276 = 480 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 680 EnerovPrp 5.1 by Ene-mySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 26 of 30 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Clearwater/Sparks Residence ROOM INFORMATION DESIGN CONDITIONS Room Name GreaWitchen/Dining/Gallery Outdoor Dry Bulb Temperature Floor Area Z777.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: nnan"P Rnrfar_Ps R-38 Roof(R.38.2x 12.16) R-21 Wall (1..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W. 21.2x6.16) R-21 Wall (W. 21.2x6.16) (N) (NE) Date 5/15/2013 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2, 750.0 0.0260 56.0 78.0 0.0690 23.0 347.9 0.0690 30.3 174.9 0.0690 29.3 110.1 0.0690 26.0 24.0 0.5000 26.0 76.5 0.0690 31.7 201.8 0.0690 33.0 54.3 0.06901 29.3 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnPStrattnn Skylight Skylight Skylight C 9 J 8 G BB (N) (NE) Page Total Shaded Area GLF Unshaded Area + 9.0 GLF X 83.7 X 83.7 X 83.7 X 22.3 X 38.4 X 38.4 X 38.4 X 38.4 X 38.4 Page Total = = = = = = = = = 0.0 X 30.9 0.0 X X 30.9 + + + + + + 9.0 0.0 30.9 9.0 0.0 X X X X 22.3 22.0 103.8 22.3 76.2 22.1 22.3 8.5 32.7 22.3 57.3 0.0 X 22.3 + 45.5 +1 3.0 0.0 X 22.3 112 OF 78 OF 34 OF lu/hr 4,004 124 728 354 198 312 167 459 110 Btu/hr 754 754 754 490 5,234 818 2,926 1,745 115 13.589 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 151.96 X 34 = 4,761 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,243 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 151.96 X 0.00276 = 1,734 Air Sensible CFM ELA AW • TOTAL HOURLY LAT • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name GreabKitchen/Dining/Gallery Outdoor Dry Bulb Temperature 112 OF Floor Area 2,777.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temaerature 78 OF Outdoor Dailv Ranoe: 34 OF Area U -Factor CLTD' X X = X X = X X _ X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FanPstratinn BB H F BB BB BB E AA AA Orientatinn (NE) (SE) (SE) (SE) (SE) (SE) (S) (S) (S) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = Btu/hr 0.0 22.3 3.0 38.4 115 0.0 22.3 35.0 28.3 990 0.0 22.3 23.1 28.3 653 0.0 22.3 3.0 28.3 85 0.0 22.3 3.0 28.3 85 0.01 22.3 3.0 28.3 85 0.0 22.3 90.0 22.4 2,013 0.0 22.3 2.3 22.4 51 0.0 22.3 2.3 22.4 51 Page Total 4,129 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 151.96 X 34 = 4,761 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,2431 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 151.96 X 0.00276 = 1,734 Air Sensible CFM ELA AW J \1 4 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Clearwater/Sparks Residence 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Dining/Gallery Outdoor Dry Bulb Temperature 112 OF Floor Area 2,777.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr AA (S) 0.0 X 22.3 + 2.3 X 22.4 = 51 T (S K9 0.0 X 22.3 + 85.5 X 32.2 = 2,756 88 (SIM 0.0 X 22.3 + 3.0 X 32.2 = 97 BB (S K9 0.0 X 22.3 + 3.0 X 32.2 = 97 B (lM 0.01 X 22.3 + 61.2 X 45.4 = 2,780 A (NM 0.0 X 22.3 + 31.5 X 34.8 = 1,097 1 (NM 0.0 X 34.9 + 36.0 X 47.1 = 1,696 U (NIM 0.0 X 22.3 + 43.2 X 34.8 = 1,504 X +1 1 X1 I = Page Total 10,078 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = �-10 Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 x 0.87 X 151.96 X 34 = 4,761 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,243 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4.771 X 0.87 X 151.96 X 0.00276 = 1,734 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,934 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Pa a 29 of 30 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Clearwater/Sparks Residence 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 386.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 12.16) 386.0 X 0.0260 X 56.0 = 562 R-21 Wall (W. 21.2x6.16) . (E) 64.0 X 0.0690 X 33.0 = 146 R-21 Wall (W.21.2x6.16) (S) 178.0 X 0.0690 X 26.0 = 319 R-21 Wall (W.21.2x6.16) (IM 220.0 X 0.0690 X 33.0 = 501 X X = X X = X X = X X = X J X = Page Total 1,528 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 7 (S) 0.0 X 22.3 + 64.0 X 22.4 = 1,431 X + X - X + X - X + X - X + X - X + X - X + X - X + X - X +1 xi - Page Total 1,431 Internal Gain . Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = f0 Infiltration: 1.064 X 0.87 X 21.12 X 34 = 662 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,851 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 21.12 X 0.00276 = 241 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 441 Ene Pro 5.1 by Enemysoft User Number.* 6712 RunCode: 2013-05-15T13:32:46 ID: Pa a 30 of 30 Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed at CalCERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1511512013 Date Project Address 53-540 Del Gato Drive, The Traditions La California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,226 Addition n1a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features art 2 of 5 Status Roof Wood Framed Attic R-38 5,199 Radiant Barrier New Wall Wood Framed R-21 3,394 New Slab Unheated Slab -on -Grade None 5,226 Perim = 414' New Door Opaque Door None 24 O I (i F< 6(12 Q ..:F FENESTRATION `` U. Exterior til�cN Orientation Area 1 Factor SHGC Overhang Sidefins Shades T Status Left, (N) 151.8 h 0.390 0.39 none none Bug Screen New Rear`(NE) _ 182.5 �p .0:390 0.39- none .:.:_none_ Bug,Screen,; New '� 39�r 0 39 " none ,; � ..none , Right (SE) : ° 112.1 T " (px� 6,:, - ""Bug Screen �� , New Front (&lNJ- ; ,- 189 5 0:390 0 39 : ;none _ none ` Bug Screen; New Skylight ` § 9.0 0.800 0139 =%noneee J none x _„,_; „� . .4NoneyNe`w Skylight\,, `'.'" .1 „ ti 9 04 0 800 0 39 n ' \none,, „ ;; None Skylight `: 9.0 ' r, 0.800 0 39.: -;:none none -" None New Rear (NE) ,, m '� 180.0. ..0.390 0.39 22.0 none Bug Screen New Rear (NE), 30.6 0.390 0.39 18.0 none Bug Screen New Rear (NE) 90.0 0.390 0.39 14.0 none Bug Screen New Right (S) 160.9'.,; . 0.390 0.39 none none Bug Screen New HVAC SYSTEMS City. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New •. 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 65 0.96 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Pae 1 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed'at CalCERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type 0 Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 5/15/2013 Project Address 53-540 Del Gato Drive, The Traditions La California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5, 226 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes. ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FEN ESTRATION:,:r'' 'I1,U- Exterior _.,._._Area ii; Factor SHGC Overhang Sidefins Shades Status .Orientation Font (IAS 61.2 ...,0.390 0.39 none none Bug Screen New LeibVIO 74.70 390 0 39 none -- none Bug,Screen New Left (Nl<1�?� r,.F- _ � 3R : 36.0Bug New i 111A 's Mill x.. HVAC SYSTEMS My. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 2 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/15/2013 Electronically Signed at CalCERTS.com by Nicole Charon (Fedderly &Associates) 5/16/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family 0 Addition Alone Date ClearwaterlSparks Residence O Multi Family 13Existing+ Addition/Alteration 5/15/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. , The DHW System Lochinvar #SNR126-065 is a non-NAECA large storage gas water heater. Verity DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se crate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix RA3.3 must be met. HIGH MASS Design - Verity Thermal Mass: 9 70. 0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 324.0 ft' Exposed Slab Floor, 3.500" thick at Master Bedroom The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se crate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix R43.3 must be met. HIGH MASS Design - Verify Thermal Mass: 566.0 ft' Covered Slab Floor, 3.500" thick at Guest 1/ Office HIGH MASS Design - Verity Thermal Mass: 203.0 ft2 Exposed Slab Floor, 3.500" thick at Guest 1/ Office The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the airflow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thema Wass: 266.0 ft2 Covered Slab Floor, 3.500" thick at Great/Kitchen/Dining/Gallery ,HIGH MASS Design - Verify Thermali!Mass: 2,511.0 ft' Exposed Slab Floor, 3.500" thick at Great/Kitchen/Dining/Gallery ::..... -....r . HIGH MASS Design - Verity Thermal Mass;;. 327.0 ft' Covered Slab Floor, 3.500" thick at Guest 2 i €.. HIGHaMASS7�D✓esTgn Venjly Thermal, Mass 59--y0 - Exposed Sl6b Floor 3'500 lhickiat Guest 2 F�.i.i The Roof R;38,Roof(Ri38 2 42 16) includes credit`for a Radiant Barrer that 1s�f,Continuous meeting eligibildy and�installatlon cntena;as specified in Residential -A endix _ HEFtSREQUIRED�1�/ERIFICATIONi Items m section f a field testing antl/or ver(f(cation bya certified HERS Rater"!The mspeetor th(s regwre rnustreceive coli leted CF;;4R form"for`each '0" 65measures'listed-below for final to be" Ivan: The Cooling System.,.Carrier 24APA760/58PH'110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verity the installation of -.;- the correct Condenser The HVAC`System HVAC 4,incorpoi ieiiHERS Verified Refrigerant Charge or a Charge Indicator Display. is ), The HVAC System HVAC 1 incorppiates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified cntena :: The Cooling System Carrier 24ACA736/58PH•090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH'110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC.3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Erie Pro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 3 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed'at CalCERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Clearwater/Sparks Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/15/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2- Space Heating 3.57 3.02 0.56 Space Cooling 51.52 45.79 5.73 Fans 10.24 14.32 -4.08 Domestic Hot Water 6.98 3.91 3.07 Pumps 0.00 0.00 0.00 Totals 72.31 67.04 5.27, Percent Better Than Standard: 7.3% BUILDING COMPLIES '- HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (w) 970 251 Fuel Available at Site: Natural Gas (N) 1,245 263 Raised Floor Area: 0 (E) 1,178 483 Slab on Grade Area: i 5,226 (S) 1,295 273 Average Ceiling Height:...:....' €,: 11.9 Roof 5,226 27 ii; Fenestration .Average U -Factor: 0.41 TOTAL: 1,296 Avera a SHGC� = . 0.39 Fenestration/CFA Ratio: 24.8 REM ARKS"`-= ;'' r Lot 80 -The Hideaway I �g'" 1p(C y 7 tl f y�1 tt y .- 4 .....r. .....n: ... .' ......... . ...._ .:nn ... :: ....:.: :.....__ .. ......::......... 1. f.: .. .. STATEMENT�OF COMPLIANCE Th slcert to of compliance;i ists the building features and specifications needed to comply with Title 24 .P�arts'1 the Administrative Regulations and Part 6 the Efficiency Standards of'tl'e�.Cal.fornia Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 5/15/7013 Address 77-085 Michigan Drive Name Tim Scott Ci /State/Zi ' Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Associates City/State2ip Palm Desert Ca 92253 Phone (760) 773-0875 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 4 of 8 Reg: 213-N0016858C-000000000-0000 Registration'Date/Time: 2013/03/20 12:36:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/15/2013 Electronically Signed at Ca10ERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 CERTWICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511512013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Roof -gAwX 1,294 0.026 R-38 270 0 New 4.2.1-A9 Master Bedroom Wall 219 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 184 0.069 R-21 60 90 New 4.3.1-A6 Master Bedroom Wall 403 0.069 R-21 150 90 New 4.3.1-A6 Master Bedroom Wall 187 0.0691R-21 330 90 New 4.3.1-A6 Master Bedroom Slab 970 0.730 None 0 180 New 4.4.7-A 1 Master Bedroom Slab 324 0.730 None 0 180 New 4.4.7-A1 Master Bedroom' Roof 769 0.026 R-38 270 0 New 4.2.1-A9 Guest 1/0foe Wall 229 0.069 R-21 0 90 New 4.3.1-A6 Guest 1/Office Wall 55 0.069 R-21 60 90 New 4.3.1-A6 Guest i/Office Wall 44 0.069 R-21 90 90 New 4.3.1-A6 Guest 1/Office Wall 132 0.069 R-21 150 90 New 4.3.1-A6 Guest 1/Office Wa11 221 0.069 R-21 240 90 New 4.3.1-A6 Guest 1/Office Wall 215 0.069 R-21 330 90 New 4.3.1-A6 Guest 1/01fice Slab 566 0.730 None 0 180 New 4.4.7-A1 Guest 1/0ffice Slab 203 0.730 None 0 180 New 4.4.7-A1 Guest 1/Office FENESTRATION SURFACE,DETAILS ID Type Area .' U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 37.8. " 0.390 NFRC 0.39 NFRC 0 New Dual non Metal Tinted Master Bedroom 2-_ Window 24.0 0.390 .NFRC 0.39 NFRC 0 New Dual non Metal Tinted Master Bedroom 3 Window " +' 4.0 0.390 NFRC, 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 4;. window 88.0 0.390 NFRC. 0.39 NFRC 60 New Dual non Metal Tinted Master Bedroom 5 N Window, . 3.0 0.390 NFRC: ": 0.39_.NFRC New�.� ,DuaLnon,MetalTinted_ _ -- .. ,Master Bedroom 6' ..' Mf7dow':. 30 .0.390 NFRC;.; 0.39';NFRC "<` ^` f60 New ,: Dual;non A9etal:Tmted,., Master Bedroom 7 ' lNindow 1"3.0 0:390 ,NFRC `,"A.39'NFRC :-- 60 `New, Dua1non:Metal Tmtedi;- ' . _ ' Master Bedroom 8 window, 30 0; 0.390, NFRC ;- ", " .' 0.39 NFRC ';' r " 60 New, " Dual non,iMetal:Tinted A,; Master Bedioom - - 9 Window 1,5?0 ,10:390 NFRC 0.39 NFRC ,; x';150 ,New `; Dual non MetafTinted : ; . L- Master�aedrooMr, ,p . 10 Window#30:0, x".0.390'- NFRC 7 ;; 0.39! NFRC `r ' X150 Newer. '): Duals=non Metal Tinted ', Master Bedroom 11 :: VlQndaw 1' X4.0 X0:390"NFRC - *-x-0.39 'NFRCLL ,':0 New k DuaA n MetaljTinted; "" ;,<'Gudst'110 6-"q b, 12'" Window,.-IWndow,.-I 64 0 ':; )0"39.0, NFRC 0.39' NFRC_': ; . 0 ,New ` =.- "Dual non MetafTinted Guest 1/Office 13 Window _ 31.5 0.390 NFRC :: 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 74.- Window " '27:0 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 15'.. Window n:: = 31'5 0.390 NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 16 Window 4Q. 1,_0.390; NFRC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office (1) U -Factor Type: ;,1.16-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: P1'6-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Ove hanq Left Fin at Wd Len Hat LExt RExt Dist I Len Exterior Shade Type SHGC Hc Ri ht Fin Hot I Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bu Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 IBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15713:32:46 ID: Page 5 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed at C'a10ERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type O Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 2,750 0.026 R-38 270 0 New 4.2.1-A9 Living Zone Wall 78 0.069 R-21 0 90 New 4.3.1-A6 Living Zone Wall 348 0.069 R-21 60 90 New 4.3.1-A6 Living Zone Wall 175 0.069 R-21 150 90 New 4.3.1-A6 Living Zone Wall 110 0.069 R-21 180 90 1 New 4.3.1-A6 Living Zone Door 24 0.500 None 180 90 New 4.5.1-A4 Living Zone Wall 77 0.069 R-21 240 90 New 4.3.1-A6 Living Zone Wall 202 0.069 R-21 270 90 New 4.3.1-A6 Living Zone Wall 54 0.069 R-21 330 90 New 4.3.1-A6 Living Zone Slab 266 0.730 1 None 0 180 New 4.4.7-A1 Living Zone Slab 2,511 0.730 None 0 180 New 4.4.7-A1 Living Zone Roof 386 0.026 R-38 270 0 New 4.2.1-A9 Guest 2 Wall 64 0.069 R-21 90 90 New 4.3.1-A6 Guest 2 Wall 178 0.069 R-21 160 90 New 4.3.1-A6 Guest 2 Wall 220 0.069 R-21 270 90 New 4.3.1-A6 Guest 2 Slabl 327 0.730 None 0 180 New 4.4.7-A 1 Guest 2 FENESTRATION SURFACE: DETAILS ID Type Area :0-17actor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0: 0.390 NERC 0.39 NFRC 240 New Dual non Metal Tinted Guest 1/Office 18_,� Skylight 9.0 0.800 NFRC 0.39 NFRC 270 New Skylight Living Zone 19 S li ht'* '' 9.0 0.800 ',NFRC 0.39 NFRC 270 New Skylight Livin Zone 20. Skylight 9.0 0.800 NFRC, 0.39 NFRC 270 New Skylight Living Zone 2T: Window_----. 22.0 0.390 NFRC :" „0=39, NFRC..._.v 0 New...Dual:ngn Metale.Tinted,...,,_,., Living Zone 22 _L. Window , 7' 1.80:0 0.390 'NFRC,;;; 0.39' NFRC 160 New �,, � Dual,{non Metal "Tinted,' (. $,. Living Zone 23 lhrindow, X30:6 0 390 ,NFRC 'NFRC ; . "6Q :Naw ;4 '� Dual non; Metal `T hied'. _ � Living Zone 24 Window.' 90.0< ;0 390J NFRC 0.39 NFR_`C 60 New "� Duahnon YMetal Tinted ) Living one "-- - 25 Krindow 4,515 f0.390 ,NFRC . ;;;: 0.39 NFRC; lk,,'60 ,New ';; `. Dual norr"MetahTinted Living;Zone, 26 Window 3.0, ;0 3901 NFRC , ": 0.39" NFRC `°" r 60' ?New: A Dual'non Metal Tinted: LivingrZone!. f `. 27 Windows l':.. 3.0 x;0'390; NFRC ,, .. 0 39;'NFRC x`60 New . , Duahnon Metal Tmtedw:.., '+' L;iymg,Zone ' ., O 28'1 Window.,.. , :.35:0 ;039.0 NFRC' ':" 0.39 NFRC;, 15.o New .:' ' 'Duahnon MetahTinted:; living Zone 29 Window " 23.1 0.390 NFRC 0:39 NFRC 150 New Dual non Metal Tinted Livin Zone x'30.- Window x.3.0 0.390 NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone 31 :: Window 3:0 0.390 'NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone 32 Window `3:0; 'x. 0.390, NFRC 0.39 NFRC 150 New Dual non Metal Tinted Living Zone (1) LI -Factor Type: `Q----` ] 16-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: ".f:16,B =: D'efauft Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin H t Wd Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 None 1.00 19 None 1.00 20 None 1.00 21 Bug Screen 0.76 22 Bug Screen 0.76 10.0 18.0 22.01 0.1 22.0 22.0 23 Bug Screen 0.76 6.5 4.7 18.0 0.1 18.0 18.0 24 Bug Screen 0.76 10.0 9.0 14.0 0.1 14.0 14.0 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 EnargyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-15T13:32:46 ID: Page 6 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/15/2013 Electronically Signed at CalCERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Clearwater/Sparks Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511512013 OPAQUE SURFACE DETAILS Surface U- Insulation -Joint Appendix Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Slab 59 0.730 None 0 180 New 4.4.7-A1 Guest 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 90.0.: 0.390 NFRC 0.39 1 NFRC 180 New Dual non Metal Tinted Living Zone 34::; Window 2.3 0.390 NFRC 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 35 Wiridd1ty + 2.3 0.390 ',NFRC 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 36 Window 2.3 0.390 NFRC. 0.39 NFRC 180 New Dual non Metal Tinted Living Zone 37:N lMndow, 85.5.0.390 NFRC' : _0:39. NFRC._._... _ .__2_4,0 New. ,,-,--.Dual RQn Metal_Tinted,-._Living Zone _. 38... Window' ,' /3:0 0.390 'NFRC':',, "0.39';NFRG . 240 New : a Duafnon MetarTinted S ,'Living Zone 39 = Vtrindow :: 3.0 0:390 NFRC . _ 0:39 'NFRC :..:. 240 'New; f "� Living Zone A Dual rion.Metal Tinted;, 46 endow: 61.2; ;;0.390 NFRC.-' " r`.' 0.39 NFRC . .276 New 'Dual nonYMetal,Tinted X. Living Zone 41 Window 3.1:x5 0.390 .NFRC 0.39 NFRC=".. . 330 ,New Dual non Metat7inted ;,tib Livirig,Zone, 42 ,Window ; 36:0, a "1.040 ,NFRC -;1 0.30;' NFRC.-;,, .. ;430: eNaw. 'J Custom Door f t ) Living Zone ` pl; e1,`", 43 ;' Window f° 43.2' ; 0.390 NF_RCa' ' X0.39 NFRC_ X330 New; ` Dual°non Metal Tinted ; Lwing_ZoniC3 44r? Window, ,...:.,; ..64:0 0:390 NFRC' ' `'` 0.39' NFRC.:; ".:1:80, New .: 'Dual-non"Metaf Tinted.: ,, : Guest 2 _. `3 (1) U -Factor Type: =: -:11.6 A = Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: `:146-B=,Defauh Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Ri ht Fin ID Exterior Shade Type SHGC Hat I Wd Len Hat LExt I RExt Dist Len Hat Dist Len I Hat 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 jBug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 EnemyPfo 5.1 by EnefgySoft User Number., 6712 RunCode: 2013-05-15T13:32:46 /D: Pae 7 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott andAuthenticated at CalCERTS.com - 5/15/2013 'Bl�_ctronically Signed at CalCERTS.com by Nicole Charon (Fedderly & Associates) 5/16/2013 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project NameType ClearwaterlSparks Residence Building ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existinq Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,294 16,304 HVAC 2 Guest 1/ Office 769 8,151 HVAC 3 & 4 GreaWitchen/Dining/Gallery 2,777 33,602 Guest 2 386 4,246 Totals 5,226o 0 0 HVAC SYSTEMS - ` Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 "- 1 lk Central Furnace 80%AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 2 1 `! ,Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New v HVAC 3 8 4 -, ,; 2 Central;Fumace ; r80.%AFUE SplitAit Conditioner 16°5 SEER„ Sefback_,,:. New � R S t �. f.' �;�f �@v,,;, ?'3"i 1 )I d3."'y .,yif. s'�..;}f{�'� , _ r�s R;" ,I,�'..:. '.' �'�✓..:�t� ..:.'.*4 -.�, ; :.: .�ib'Y' ... '. ""1171 . ' a ae..d�(€:i�'?"'l:t ,' HVACDI$TRIBUTI O.N<�� An,::ARW t - '> 1Duct '/ DiictsC; S'stem::Name , Heating Coolin ._: .. Duct.L - Aon.... R..Value Tested? Status .:: HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2,',-': Ducted ti _' Ducted Attic, Ceiling Ins, vented 8.0 m New HVA: ¢ Ducted (` Ducted Attic, Ceiling Ins, vented 8.0 d New i..�_ ❑ WATER HEATING SYSTEM5t S stem Name at . TvDe Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Lochinvar #SNR126-065 1 Large Gas All Pipes Ins 126,000 65 0.96 0.00 % 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length' ft C 0 76 v a c System Name Pipe Length Pipe Diameter Insul. Thick. Qty.THP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-05-15713:32:46 ID: Page 8 of 8 Reg: 213-N0016858C-000000000-0000 Registration Date/Time: 2013/03/20 12:36:20 HERS Provider: Ca10ERTS', Inc