Loading...
13-1682 (SFD) Title 24., . BUILDING ENERGY ANALYSIS REPORT I PROJECT: Abel Residence Lot 65, Traditions La Quinta, CA 92253 Project Designer: Helton, DeFord & Associates 17411 Irvine Blvd., Suite O Tustin, CA 92780 (909) 957-4550 Report Prepared by: r3 Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 CP- OF � BUIQUIi�T,q. WING & SAFETY DEPT. APPPnw-ate--.. Job Numkler'4TE CITY OF Ll QUINTA Date: COMMUNITY DEVELOP MENT 3/18/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2014.03-18714:22:52 ID: PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Abel Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/18/2014 project Address Lot 65, Traditions La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,874 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form: D Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,874 Radiant Barrier New Wall Wood Framed R-21 4,083 New Slab Unheated Slab -on -Grade None 5,874 Perim = 514' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area f Factor SHGC Overhang Sidefins Shades Status Rear (NE) 262.0 0.390 0.36 none none Bug Screen New Right (SE) 221.0 0.390 0.36 none none Bug Screen New Left (NM 160.0 0.390 0.36 none none Bug Screen New Front (SW) 56.0 0.390 0.36 none none Bug Screen New Rear (NE) 231.0 0.390 0.36 20.0 none Bug Screen New Front (SVIO 115.0 0.950 0.49 5.0 none Bug Screen New Left (NVV) 18.0 0.390 0.36 20.0 none Bug Screen New Left (NVV) 48.0 0.390 0.36 15.0 none Bug Screen New HVAC SYSTEMS City. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 & 4 Ducted Ducted Attic, Ceiling4gs;; vented T- a X8.0®. - New WATER HEATING �r ° r �a �_t"6 �UII ! /A Ot . Type Gallons Min. Eff Distribution._& SAFETY DEPT. IStatus 2 Small Gas 75 - t— M U � � LJ 1Jn'S ' 0.65 1 All Pipes pIns _ New r vr-i UUI145I ROC I I UAE BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-1871422:52 /D: Page 3 of 29 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Abel Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 3/18/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 978.0 ft' Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 286.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 635.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 105.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 386.0 ft2 Covered Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 63.0 ft2 Exposed Slab Floor, 3.500" thick at Casita The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 274.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4 HIGH MASS Design - Verify Thermal Mass: 46.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4 HIGH MASS Design - Verify Thermal Mass: 316.0 ft2 Covered Slab Floor, 3.500" thick at Great/Dining/Kitchen HIGH MASS Design - Verify Thermal Mass: 2,785.0 R' Exposed Slab Floor, 3.500" thick at Great/Dining/Kitchen The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 24ANS760158CVX090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification-and-diagnostic.testing.is required to verify that duct leakage meets the specified criteria.�- DDILDING & SAFETY DEPT. N APPROVED. DATEBY I --._ FnemyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2014-03-1 8 714:22:52 ID: a e 4 of 29 0 L PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Abel Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 3/1812014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2 r Space Heating 3.68 4.07 -0.38 Space Cooling 50.04 42.11 7.93 Fans 9.99 13.33 -3.35 Domestic Hot Water 6.21 6.68 -0.47 Pumps 0.00 0.00 0.00 Totals 69.92 66.19 3.73 Percent Better Than Standard: 5.3 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SM 225 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S KO 921 171 Fuel Available at Site: Natural Gas (NM 1,674 226 Raised Floor Area: 0 (NE) 1,075 493 Slab on Grade Area: 5,874 (SE) 1,548 221 Average Ceiling Height: 12.4 Roof 5,874 0 Fenestration Average U -Factor: 0.45 TOTAL: 1,111 Average SHGC: 0.37 Fenestration/CFA Ratio: 18.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, All'�� 3/18/1014 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that=compliance-using-duct design, duct insulation installation building erivel'opd's,eealin sealing, verification of refrigerant charge, qualitytiarid g 1eq installer testing and certification and field verification by an approved HERSi1raterDING & SAFETY DEPT. 't Designer or Owner (per Business & Professions Code)APPR®V 0 Company Helton, DeFord & Associates F C' NSTR N Address 17411 Irvine Blvd., Suite O Name Jim Deford I City/State/Zip Tustin, CA 92780 Phone (909) 957-4550 DATE igned Bir License # Date EnerqyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2014 03-18 714 22:52 ID: Pa e 5 of 29 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Abel Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1311812014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame interiorl Frame Azm I Tilt Status 4 Location/Comments Roof 1,264 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Wall 185 0.069 R-21 45 90 New 4.3.1-A6 Master Suite Wall 58 0.069 R-21 135 90 New 4.3.1-A6 Master Suite Wall 30 0.069 R-21 225 90 New 4.3.1-A6 Master Suite Wall 605 0.069 R-21 315 90 New 4.3.1-A6 Master Suite Slab 978 0.730 None 0 180 New 4.4.7-A1 Master Suite Slab 286 0.730 None 0 180 New 4.4.7-A1 Master Suite Roof 740 0.026 R-38 270 0 New 4.2.1-A9 Bedroom 2 & 3 Wall 159 0.069 R-21 135 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 30 0.069 R-21 225 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 321 0.069 R-21 315 90 New 4.3.1-A6 Bedroom 2 & 3 Slab 635 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 & 3 Slab 105 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 & 3 Roof 449 0.026 R-38 270 0 New 4.2.1-A9 Casita well 50 0.069 1 R-21 45 90 New 14.3.1-A6 Casita well 1661 0.069 R-21 135 1 90 New 14.3.1-A6 Casita FENESTRATION SURFACE DETAILS ID Type I Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 126.0 0.390 NFRC 0.36 NFRC 45 New Double non-metal tinted Master Suite 2 Window 10.0 0.390 NFRC 0.36 NFRC 45 New Double non-metal tinted Master Suite 3 Window 36.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Master Suite 4 Window 18.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Master Suite 5 Window 18.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Master Suite 6 Window 36.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Bedroom 2 & 3 7 Window 8.0 0.390 NFRC 0.36 NFRC 315 New Double non-metal tinted Bedroom 2 & 3 8 Window 36.0 0.390 NFRC 0.36 NFRC 315 New Double non-metal tinted Bedroom 2 & 3 9 Window 24.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Casita 10 Window 14.0 0.390 NFRC 0.36 NFRC 225 New Double non-metal tinted Casita 11 Window 18.0 0.390 NFRC 0.36 NFRC 225 New Double non-metal tinted Casita 12 Window 18.0 0.390 NFRC 0.36 NFRC 225 New Double non-metal tinted Casita 13 Window 8.0 0.390 NFRC 0.36 NFRC 315 New Double non-metal tinted Casita 14 Window 8.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Bedroom 4 15 Window 15.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Bedroom 4 16 Window 15.0 0.390 NFRC 0.36 1 NFRC 135 New Double non-metal tinted Bedroom 4 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76- 9 Bug Screen 0.76 1 U i I Y iz� I i1 n I I N I - .n 10 Bug Screen 0.76 M I�r, I►t ��, :�. _ _ 11 Bug Screen 0.76 - `'�` �; `�% �t 1 Y LCL FT N 12 Bug Screen 0.76 N IQ r i 13 Bug Screen 0.76 gr r*ir-- 14 Bug Screen 0.76 I9Uu I UN 15 Bug Screen 0.761 1 16 lBug Screen 0.761 1Q r� EnergyPro 5.1 Fy'EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 ID: Page 6 of 29 1� CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Abel Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/18/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 210 0.069 R-21 225 90 New 4.3.1-A6 Casita Wall 177 0.069 R-21 315 90 New 4.3.1-A6 Casita Slab 386 0.730 None 0 180 New 4.4.7-A1 Casita Slab 63 0.730 None 0 180 New 4.4.7-A1 Casita Roof 320 0.026 R-38 270 0 New 4.2.1-A9 Bedroom 4 Wall 40 0.069 R-21 45 90 New 4.3.1-A6 Bedroom 4 Wall 222 0.069 R-21 135 90 New 4.3.1-A6 Bedroom 4 Wall 150 0.069 R-21 225 90 New 4.3.1-A6 Bedroom 4 Slab 274 0.730 None 0 180 New 4.4.7-A1 Bedroom 4 Slab 46 0.730 None 0 180 New 4.4.7-A1 Bedroom 4 Roof 3,101 0.026 R-38 270 0 New 4.2.1-A9 Great/Dining/Kitchen Wall 307 0.069 R-21 45 90 New 4.3.1-A6 Great/Dining/Kitchen Wall 722 0.069 R-21 135 90 New 4.3.1-A6 Great/Dining/Kitchen Wall 306 0.069 R-21 225 90 New 4.3.1-A6 Great/Dining/Kitchen Door 24 0.500 None 225 90 New 4.5.1-A4 Great/Dining/Kitchen Wall 345 0.069 R-21 315 90 New 14.3.1-A6 Great/Dining/Kitchen FENESTRATION SURFACE DETAILS ID Tvpe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 231.0 0.390 NFRC 0.36 1 NFRC 45 New Double non-metal tinted Great/Dining/Kitchen 18 Window 126.0 0.390 NFRC 0.36 NFRC 45 New Double non-metal tinted Great/Dining/Kitchen 19 Wndow 5.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Great/Dining/Kitchen 20 Window 5.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Great/Dining/Kitchen 21 Window 5.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Great/DiningAitchen 22 Window 18.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted Great/Dining/Kitchen 23 Window 18.0 0.390 NFRC 0.36 NFRC 135 New Double non-metal tinted GreatlDining/Kitchen 24 Window 115.0 0.950 NFRC 0.49 NFRC 225 New Entry Door Great/Dining/Kitchen 25 Window 6.0 0.390 NFRC 0.36 NFRC 225 New Double non-metal tinted GreatlDining/Kitchen 26 Window 18.0 0.390 NFRC 0.36 NFRC 315 New Double non-metal tinted Great/Dining/Kitchen 27 Window 108.0 0.390 NFRC 0.36 NFRC 315 New Double non-metal tinted Great/Dining/Kitchen 28 Window 48.0 0.390 NFRC 0.36 NFRC 315 New Double non-metal tinted Great/Dining/Kitchen (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len I H t Dist Len H t 17 Bug Screen 0.76 11.0 21.0 20.0 0.1 20.0 20.0 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 10.0 11.5 5.0 0.1 5.'O= -&0- -- - _ 25 Bug Screen 0.76 (:I I% p F l a n r� 26 Bug Screen 0.76 11.0 10.0 20.0 0.1 2d 0 20.-0," 27 Bug screen 0.76 1 L.10`1"y"%Ju. T tl Y 28 Bug Screen 0.76 8.0 6.0 15.0 0.1 15.0 15:0; ? ! ; A r K--- r 1 3FY61;'UGTl DN y1 I �,.------_ BY i5neflgyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201403-18T14:22:52 ID: Page 7 of 29 0 CE-RTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Abel Residence Building Type 0 Single Family 0 Multi Family 0 Addition Alone 0 Existing+ Addition/Alteration OPAQUE Joint Appendix 4 Location/Comments FENESTRATION .Standards, ...Standards, .- -. :. 0 1� 17, CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Abel Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 131181,2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC 1 Master Suite 1,264 15,926 HVAC 2 Bedroom 2 & 3 740 7,400 Casita 449 4,490 HVAC 3 & 4 Bedroom 4 320 3,200 Great/Dining/Kitchen 3,101 41,864 Totals 5,874 0 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 3 & 4 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 ® New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 D New WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White 75 Gal 2 Small Gas All Pipes Ins 65,000 75 0.65 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC-HEATIN_ G SYSTEM PIPING Control Hot Water Piping Length ft . N a I Y OFLA - — ETY� A BUILDIIi4C &QuipSAf i P-ipe®Pip 4EWO�11e Vit) Diam ter Insul. Thick. Qt . HP Plenum Outside Buried ❑ 4- Iwo IN1 JCTIOA ❑'UHE Ene Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 ID: Page 9 of 29 r 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Abel Residence 3/18/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - i R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 1§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ed with a with a readilyaccessible operable, and ti ht-fittin damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15,psi, meets the requirements of Standards Table 123-A. I r-% c r , „_ — 150 ' 3A: Insulation is protected from damage, including that due to sunlight! mo"iAura a ui menlN° a ntenancei�and,w)nd! §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a-vap"or�refa�dan4=o.P�isen�cfgsedZetirely in conditioned space. n +-+ rte. r-+ ,.— §150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Ratin ,andlCertif cation Q6r oration. r EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-18,T14:22:52 1D:— By Page 10 of 29 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date bel Residence 1311812014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 4150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. T__'�_ — §150(k)9: Permanently installed lighting that is internal to cabinets shall use no' more than.20 watts of power per linear foot 6f illuminated cabinet. �._ �•..w ca .�ryr Lz Full CCINSTnUCTiON EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2014-03-18T14.,22:52:.- _ _^ ID: age 11 of 29 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Abel Residence 1311812014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)l 1: Permanently. installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APF ROWED FOR CONSTRUCTION DATE BY 1:En,:,T:g:y:P::m 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18T14:22:52 - ID: Page 12 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 0.0 % Project Name bel Residence 1,059 Aug 3 PM 89,000 Outside Air cfm/s K 0.00 Vote: values above given at ARI conditions Date 3/18/2014 System Name HVAC 1 (Airstream Temperatures at Time of Heating Peak) 26 OF 72 OF Floor Area 1,264 ENGINEERING CHECKS 110 SYSTEM LOAD Outside Air Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 596 0 COOLING PEAK ° 123 F COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 13,354 1,815 261 14,263 Total Output Stuh 89,000 0 Output Btuhls ft 70.4 771 701 Cooling System 0 0 Output perSystem 49,000 0 0 0 0 Total Output Btuh 49,000 0 1,815 0 Total Output Tons 4.1 1 771 701 Total Output Btuh/s ft 38.8 Total Output s ft/Ton 309.6 1 14,896 1 15,665 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 24ANB748/58CVX090 37,405 1,059 89,000 Airflow cfm/s ft 1.27 Airflow cfm/Ton 391.8 Outside Air % 0.0 % Total Adjusted System Output 37,405 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 1,059 Aug 3 PM 89,000 Outside Air cfm/s K 0.00 Vote: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 72 OF 124 OF 124 OF 110 -- f Outside Air 0 cfm Heating Coil Supply Fan ° 123 F 1,600 cfm ROOM 72 OF .4 -dieo- 72 OF 1 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 70/57°F 48/47°F 48/47°F UG _ gyp_Outside AirAr Su I Fan r OF LA QUIN] `���° 0 cfm Cooling Coil Supply 49 4 F 1,600 cfm BUILDING & S!-\ �TV f1��e�j A P PI -°70 � 9 A OI�OIYI 70 157 OF FOR CONSTRUCTION 70/5 OF D.aTE BY EneravPro 5.1 by EnerovSoff User Number: 6712 RunCode: 2014-03-18T14:22:52 /D: age 13 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name bel Residence Date 3/18/2014 System Name HVAC 2 Floor Area 1,189 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 544 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 12,199 1,920 277 15,175 Total Output Btuh 89,000 0 Output Btuh/s ft 74.9 704 746 Cooling System 0 0 Output per System 49,0001 0 0 0 0 Total Output Btuh 49,000 0 1,920 0 Total Output Tons 4.1 1 04 746 Total Output Btuh/s ft 41.2 Total Output s ft/Ton 291.2 13,608 16,667 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Alrflow cfm 1,600 24ANB748/58CVX090 37,307 1,169 89,000 Airflow cfm/s ft 1.35 89,000 Jan 1 AM Airflow cfm[Ton 391.8 Outside Air % 0.0% Total Adjusted System Output 37,307 1,169 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 124 OF 124 OF 0 Outside Air 0 cfm Heating Coil Supply Fan 123 OF 1,600 cfm ROOM 72 OF 72 OF 1 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak J:E:,�ergy�P::ro5.1 112/78°F 70/57°F 49/47°F 49/47°F Outside Air /� ^i � Supply Fan �"'� y V F LA Q J l 49, 48 F 0 cfm CoolingCoil 1,600 cfm BUILDING � C Y 4"4'4% p RO ��FTY,[,P APF-r!U�� 70 / 57 OF FOR CONSTRUCTION 70/5 OF D.aTE �_ gY by EnergySoff User Number: 6712 RunCode: 2014-03-18714:22:52 /D: a 14 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Abel Residence 3/18/2014 System Name Floor Area HVAC 3 & 4 3,421 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 89,000 Total Room Loads 2,278 42,833 4,772 1,072 46,484 Total Output Btuh 178,000 Return Vented Lighting 0 Output Btuh/s ft 52.0 Return Air Ducts 2,473 2,285 Cooling System Return Fan 0 0 Output per System 58,000 Ventilation 0 0 0 0 0 Total Output Btuh 116,000 Supply Fan 0 0 Total Output Tons 9.7 Supply Air Ducts 2,473 1 2,285 Total Output Btuh/s ft 33.9 Total Output s f rron 353.9 TOTAL SYSTEM LOAD 1 47,779 4,772 51,053 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 24ANB760/58CVX090 80,151 13,302 178,000 Airflow cfm/s ft 1.17 Airflow cfm/Ton 413.8 Outside Air % -0.0% Total Adjusted System Output 80,151 13,302 178,000 Outside Air cfm/s ft 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions 1 TIME OF SYSTEM PEAK Aug 3P MJan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 71 OF 113 OF 113 OF Outside Air 0 cfm Heating Coil Supply Fan ° 113 F 4,000 cfm ROOM In 71 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71/59°F 52/51°F 52!51°F 0 Outside Air c O cfm Cooling Coil Supply Fan C I I T G F 1 /t U NT q;5�21 51 °F 4,000 cfm gl�®1NG �—�1 /`1 50.°��iFE__OOM. P��V�� 70/59°F 71 ! 59 °F +-[ FOR CONSTRUCTION DATE.__ BY EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201403-18T14:22:52: ID: ,Page 15 of 29 • r� L J ROOM LOAD SUMMARY Project Name Abel Residence Date 3/18/2014 System Name HVAC 1 Floor Area 1,264 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Master Suite 1 596 13,354 1,815 596 13,354 1,815 261 14,263 A Q IIN, rr A.1 I RI 11 nlNi(� P. QA 7r: rer- r IA r", r,�e-v1 B�rw ' Total includes ventilation load for zonal systems. m Y "..,d VC-- LJ PAGE TOTAL rv596� '��1F3 354 jL%�1%815 �N 261 14,263 TOTAL' 596 13,354 1,815 261 14,263 DATE gY EneMyPro 5.1 by EneMySoft User Number: 6712 RunCode: 2014-03-1 8 714:22:52 1'D: P e 16 of 29 • ROOM LOAD SUMMARY Project Name Date Abel Residence 3/1812014 System Name Floor Area HVAC 2 1,189 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible Bedroom 2 & 3 Bedroom 2 & 3 1 293 6,574 1,146 293 6,574 1,146 143 7,805 Casita Casita 1 1 2511 5,625 774 251 5,6251 774 135 7,370 I'T Frr i art' '/'T'0N277 15,175 PAGE TOTAL 544' C�12�199 R�1�,920 i TOTAL' 1 5441 12,199 1,920 277 1 15,175 DATE BY • 17, ROOM HEATING PEAK LOADS Project Name73/18/2014 Abel Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,264.0 ft2 Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F 46 = 46 = 46 = 46 = = = = = = = = = _ = = = = = = = = = = = = = = = = = = Rage Total L �k GAFF i46, ��A-T_vFraction �6L=oS ijr-TIONI Btu/hr R-38 Roof(R.38.2x14.16) 1,264.0 0.0260 1,512 R-21 Wall (W 19.2x6.16) 878.0 0.0690 2,787 Double non-metal tinted 208.0 0.3900 3,732 Slab -On -Grade perim = 88.0 . 0.7300 2,955 another roomF,& 12.60 X; Height Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible through an interior surface 1.064 X 1,264 X Area 10,985 u`ra . 3,w 78 TOTAL HOURLY HEAT LOSS FOR ROOM 14 P-631 DATE BY Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-1 8 714:22:52 -iD: eage 19 f 29 • L_ I ROOM HEATING PEAK LOADS Project Name Abel Residence Date 3/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 & 3 Floor Area 740.0 ft2 Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = - = = = Btu/hr R-38 Roof(R.38.2x14.16) 740.0 0.0260 46 885 R-21 Wall (W.19.2x6.16) 510.0 0.0690 46 1,619 Double non-metal tinted 80.0 0.3900 46 1,435 Slab -On -Grade penim = 58.0 0.7300 46 1,948 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X F____1 Schedule Air Sensible Fraction through an interior surface 064 X 740 X Area another room 10. �0 X-n3i Page Total 1 5,887 - 1,919 oWD J_J( QU1M� & SAFETY OV DEPT. Ceiling Heigh BUIAMING ^^ APP i TOTAL HOURLY HEAT LOSS FOR ROOM i FOR CoNsTRucTinN7 805 EnefgyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18T14:22: 2A I E —!Q: BY Pa 20 of 29 • • ROOM HEATING PEAK LOADS Project Name73/18/2014 Abel Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 449.0 ft' Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X QTY AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = -_6 QUtNTP. e� Btu/hr R-38 Roof(R.38.2x14.16) 449.0 0.0260 46 537 R-21 Wall (W.19.2x6.16) 603.0 0.0690 46 1,914 Double non-metal tinted 82.0 0.3900 46 1,471 Slab -On -Grade penim = 68.0 0.7300 46 2,283 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 449 X Area another roomF 10.00 X Height 0?3.118 Total OA LA _f0i]a XkSAFE96EPT.1,s4 iY AT CONSTRUCTION 205 ACH I FOR TOTAL HOURLY HEAT LOSS FOR ROOM 7 3;70 DATE BY Energ Pro 5.1 6 Ene Soft User Number. 6712 RunCode: 2014-03-18714:22:52 ID: Page 29 -of 29 • ROOM HEATING PEAK LOADS Project Name Abel Residence Date 3/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Floor Area 320.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X -V81 AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = �46] TY Btu/hr R-38 Roof(R.38.2x14.16) 320.0 0.0260 46 383 R-21 Wall (W. 19.2x6.16) 412.0 0.0690 46 1,308 Double non-metal tinted 38.0 0.3900 46 682 Slab -On -Grade perim = 41.0 0.7300 46 1,377 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 320 X Area another room �y -- 10.00 X O Height ACH I Page Total � Ir ®60.; X I --k NU & 6NY APPROVED' 1 3,749 i �e t=�� 1A 830 DEPT. I TOTAL HOURLY HEAT LOSS FOR ROOM I rUh UUIN6 1 HUCTION 4 679 1 nnrr - L — 6nergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 1 /D.- -Ra e_2 129 C7 174 ROOM HEATING PEAK LOADS Project Name7311812014 Abel Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name GreabDining/Kitchen Floor.Area 3,101.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FOR AT OF Btu/hr R-38 Roof(R.38.2x14.16) 3,101.0 0.0260 46 = 3,709 R-21 Wall (W. 19.2x6.16) 1,680.0 0.0690 46 = 5,332 Double non-metal tinted 588.0 0.3900 46 = 10,549 Entry Door 115.0 0.9500 46 = 5,026 Wood Door 24.0 0.5000 46 = 552 Slab -On -Grade perim = 259.0 0.7300 46 = 8,697 = = = = = = = = = = = = = = = = = = = = = • = = = = Items shown with an asterisk (') denote conduction Infiltration: 1.00 X Schedule Air Sensible Fraction through an interior surface X 3,101 X Area another room CITY 13.50 X t0�2F35 Height Page -Total= OF LA Qx /I60�� 4-X JAFET4,6I=[:p ®rQT, ED CONSTRUCTION --®3.3, 865 Ifel 8041 TOTAL HOURLY HEAT LOSS FOR ROOM 1 41 905 LI DATE —� BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 /D: age -2 f 29 :7 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7311812014 ate Abel Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,264.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 1,264.0 X 0.0260 X 56.0 = 1,840 R-21 Wall (W 19.2x6.16) (NE) 185.0 X 0.0690 X 29.0 = 370 R-21 Wall (W. 19.2x6.16) (SE) 58.0 X 0.0690 X 31.0 = 124 R-21 Wall (W. 19.2x6.16) (SW) 30.0 X 0.0690 X 31.0 = 64 R-21 Wall (W.19.2x6.16) (NW) 605.0 X 0.0690 X 30.2 = 1,262 X X = X X = X X = X I X I= Page Total 3,661 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1D (NE) 0.0 X 21.2 + 126.0 X 32.7 = 4,125 113 (NE) 0.0 X 21.2 + 10.0 X 32.7 = 327 110 (SE) 0.0 X 21.2 + 36.0 X 29.4 = 1,060 111 (SE) 0.0 X 21.2 + 18.0 x 29.4 = 530 112 (SE) 0.01 X 21.2 + 18.0 X 29.4 = 530 X + X = X + X - X + X - X +1 1 X = Page Total 6,572 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = EA Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 x 0.94 X 69.17 X 42 = 2,891 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,354 Latent Gain CITY OF LA QUIN ,Btu hr Occupants 1.0 Occupants X i t' 41061 Bt�u`h 6A.SAFETy p 200 A'�POVED Infiltration: 4,771 x 0.94 x 69.17 x 0.00523 = FOR CONSTRUCTION 1,615 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM "~' ---- BY 1,815 EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2014-03-18714:22:52 /D: Page 24 of 29 C C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Abel Residence 1 3118/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 & 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 740.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (M 740.0 X 0.0260 X 56.0 = 1,077 R-21 Wall (W.19.2x6.16) (SE) 159.0 X 0.0690 X 31.0 = 340 R-21 Wall (W.19.2x6.16) (SVt9 30.0 X 0.0690 X 31.0 = 64 R-21 Wall (W..19.2x6.16) (NVt9 321.0 X 0.0690 X 30.2 = 670 X X = X X = X X = X X = X X I= Page Total 2,151 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 103 (SE) 0.01 X 21.2 + 36.0 X 29.4 = 1,060 108 (NVV) 0.0 X 21.2 + 8.0 X 32.7 = 262 109 (NVt9 0.0 X 21.2 + 36.0 X 32.7 = 1,178 X + X - X + X - X + X - X + X - X + X - X +1 X - Page Total 2,500 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 40.49 X 42 = 1,693 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,574 Latent Gain 1 V,� F L QJ 1 tll/hr00 Occupants 1.0 Occupants X OO�Btuh/o "` ---Ullqu & SAFETY DEPT Infiltration: 4,771 X 0.94 X 40.49 X 0.00523 = APPROVE 946 Air Sensible CFM ELA AW FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM T� 1 146 Ener Pro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2014-03-18T14:22:52 ID: a e,2 f 29 • C 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Abel Residence 1 3/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 449.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (tM 449.0 X 0.0260 X 56.0 = 654 R-21 Wall (W 19.2x6.16) (NE) 50.0 X 0.0690 X 29.0 = 100 R-21 Wall (W. 19.2x6.16) (SE) 166.0 X 0.0690 X 31.0 = 355 R-21 Wall (W. 19.2x6.16) (Stns 210.0 X 0.0690 X 31.0 = 449 R-21 Wall (W.19.2x6.16) (NW) 177.0 X 0.0690 X 30.2 = 369 X X = X X = X X = X I X = Page Total 1 1,927 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1B (SE) 0.0 X 21.2 + 24.0 X 29.4 = 707 104 (SW) 0.0 X 21.2 + 14.0 X 29.4 = 412 105 (SW) 0.0 X 21.2 + 18.0 X 29.4 = 530 106 (SW) 0.0 X 21.2 + 18.0 X 29.4 = 530 107 (NW) 0.01 X 21.2 + 8.0 X 32.7 = 262 X + X - X + X - X + X - X +1 X - Page Total 2,441 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 24.57 X 42 = 1,027 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,625 Latent Gain Btu/hr j Occupants 1.0 Occupants X . '200 lBtuh/o cc F LLIAJ Q UU INT, '00 `RUILtDIIvC &SAFETY Infiltration: 4,771 X 0.94 X 24.57 X 0.00523 = APPROVE 74 Air Sensible CFM ELA ow FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 74 DATE EnerqvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2014-03-18T14:22:52L ----ID 29 • 4 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Abel Residence 1 3/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 320.0 ft-' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 320.0 X 0.0260 X 56.0 = 466 R-21 Wall (W.19.2x6.16) (NE) 40.0 X 0.0690 X 29.0 = 80 R-21 Wall (W.19.2x6.16) (SE) 222.0 X 0.0690 X 31.0 = 475 R-21 Wall (W.19.2x6.16) (SW) 150.0 X 0.0690 X 31.0 = 321 X X = X X = X X = X X = X J X I_ Page Total 1,342 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 117 (SE) 0.0 X 21.2 + 8.0 X 29.4 = 236 118 (SE) 0.0 X 21.2 + 15.0 X 29.4 = 442 119 (SE) 0.0 X 21.2 + 15.0 X 29.4 = 442 X + X - X + X - X + X = X + X = X + X - X +1 X = Page Total 1,119 Internal Gain Btu/hr Occu ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 17.51 X 42 = 732 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,423 Latent Gain Btu/hr Occupants 1.0 Occupants X r-200 -Btuh/occ: CITY OF L QUINITA Infiltration: 4,771 X 0.94 X 17.51 X 0.00523 = BUILDING & SAFETY 4 9 Air Sensible CFM ELA AW APPROVED I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM t -UH (.. IV5 I HUG I IO g g M EnB Pro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2014-03-18714:22:52 I . ID: Page 27 of g.9 • • I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name73/18/2014 ate Abel Residence ROOM INFORMATION DESIGN CONDITIONS Room Name GreatlDining/Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 3,101.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Or)aaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. -19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W19.2x6.16) Wood Door R-21 Wall (W. 19.2x6.16) Orientation (SE) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 3,101.0 0.0260 56.0 307.0 0.0690 29.0 722.0 0.0690 31.0 306.0 0.0690 31.0 24.01 0.5000 31.0 345.0 0.0690 30.2 21.2 18.0 29.4 0.0 85.7 21.2 18.0 29.4 37.2 29.3 48.5 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF 1E 1G 114 115 116 101 102 1A 100 I Internal Gain (NE) (NE) (SE) (SE) (SE) (SE) (SE) (SM (SM 0.0 X X X X X X X X X 21.2 + + + + + + + + + 231.0 X X X X X X X X X 32.7 = = = = = = = = = 0.0 21.2 126.0 32.7 0.0 0.0 21.2 5.0 29.4 21.2 5.0 29.4 0.0 21.2 5.0 29.4 0.01 21.2 18.0 29.4 0.0 85.7 21.2 18.0 29.4 37.2 29.3 48.5 0.0 21.2 6.0 29.4 Page Total Btu/hr 4, 515 614 1, 544 Btu/hr 7,562 4,125 147 147 147 530 530 4,607 177 17,972 Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 169.69 X 42 = 7,093 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39.411 Latent Gain Occupants 1.0 Occupants X Infiltration: 4,771 X 0.94 X 169.69 X 0.00523 = Air Sensible CFM ELA AW AL HOURLY LATENT HEAT GAIN FOR ROOM ITY OF LA Q 31UOoccG & SAFE r-1 FOR CONSTRUC 3, r � RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Abel Residence 7 3/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name GreabDining/Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 3,101.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 1 0 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 121 (NM 0.0 X 21.2 + 18.0 X 32.7 = 589 1 M (NV10 0.0 X 21.2 + 108.0 X 32.7 = 3,535 1F (NIM 0.0 X 21.2 + 48.0 X 32.7 = 1,571 X + X – X + X – X + X = X + X = X + X – X + X – Page Total 5,696 Internal Gain Btu/hr— tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 .X 169.69 X 42 = 7,093 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,411 Latent Gain Btu/hr Occupants 1.0 Occupants X 2 �0 pp UhT I®F LAI BUILDIiVGTA AFES Infiltration: 4,771 X 0.94 X 169.69 X 0.00523 = es Q 3 Air Sensible CFM ELA OW PP FOR OVED V4 C� TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 163 DAT EnemvPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2014-03-18T14:22:52 L–I - Y Page 29 of 29