13-1682 (SFD) Title 24., .
BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Abel Residence
Lot 65, Traditions
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
17411 Irvine Blvd., Suite O
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
r3 Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
CP- OF �
BUIQUIi�T,q.
WING & SAFETY DEPT.
APPPnw-ate--..
Job Numkler'4TE
CITY OF Ll QUINTA
Date: COMMUNITY DEVELOP
MENT
3/18/2014
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2014.03-18714:22:52 ID:
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Abel Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
3/18/2014
project Address
Lot 65, Traditions La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,874
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form:
D Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 5,874 Radiant Barrier New
Wall Wood Framed
R-21 4,083 New
Slab Unheated Slab -on -Grade
None 5,874 Perim = 514' New
Door Opaque Door
None 24 New
FENESTRATION U- Exterior
Orientation Area f Factor SHGC Overhang Sidefins Shades Status
Rear (NE) 262.0 0.390
0.36 none none Bug Screen New
Right (SE) 221.0 0.390
0.36 none none Bug Screen New
Left (NM 160.0 0.390
0.36 none none Bug Screen
New
Front (SW) 56.0 0.390
0.36 none none Bug Screen
New
Rear (NE) 231.0 0.390
0.36 20.0 none Bug Screen
New
Front (SVIO 115.0 0.950
0.49 5.0 none Bug Screen
New
Left (NVV) 18.0 0.390
0.36 20.0 none Bug Screen
New
Left (NVV) 48.0 0.390
0.36 15.0 none Bug Screen
New
HVAC SYSTEMS
City. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.5 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 16.5 SEER Setback
New
2 Central Furnace 80% AFUE
Split Air Conditioner 16.5 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
HVAC 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
HVAC 3 & 4 Ducted
Ducted Attic, Ceiling4gs;; vented T- a X8.0®. -
New
WATER HEATING �r ° r �a �_t"6 �UII ! /A
Ot . Type Gallons Min. Eff Distribution._& SAFETY DEPT. IStatus
2 Small Gas 75
- t— M U � � LJ
1Jn'S '
0.65 1 All Pipes pIns _
New
r vr-i UUI145I ROC I
I
UAE BY
EnergyPro 5.1 by EnergySoft User Number: 6712
RunCode: 2014-03-1871422:52 /D:
Page 3 of 29
•
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Abel Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
I Date
3/18/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 978.0 ft' Covered Slab Floor, 3.500" thick at Master Suite
HIGH MASS Design - Verify Thermal Mass: 286.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite
HIGH MASS Design - Verify Thermal Mass: 635.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 & 3
HIGH MASS Design - Verify Thermal Mass: 105.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3
HIGH MASS Design - Verify Thermal Mass: 386.0 ft2 Covered Slab Floor, 3.500" thick at Casita
HIGH MASS Design - Verify Thermal Mass: 63.0 ft2 Exposed Slab Floor, 3.500" thick at Casita
The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 274.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4
HIGH MASS Design - Verify Thermal Mass: 46.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4
HIGH MASS Design - Verify Thermal Mass: 316.0 ft2 Covered Slab Floor, 3.500" thick at Great/Dining/Kitchen
HIGH MASS Design - Verify Thermal Mass: 2,785.0 R' Exposed Slab Floor, 3.500" thick at Great/Dining/Kitchen
The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System 24ANS760158CVX090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification-and-diagnostic.testing.is required to verify that duct
leakage meets the specified criteria.�-
DDILDING & SAFETY DEPT. N
APPROVED.
DATEBY I
--._
FnemyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2014-03-1 8 714:22:52 ID: a e 4 of 29
0
L
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Abel Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
3/1812014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2 r
Space Heating 3.68 4.07 -0.38
Space Cooling 50.04 42.11 7.93
Fans 9.99 13.33 -3.35
Domestic Hot Water 6.21 6.68 -0.47
Pumps 0.00 0.00 0.00
Totals 69.92 66.19 3.73
Percent Better Than Standard: 5.3
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (SM 225 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S KO 921 171
Fuel Available at Site: Natural Gas (NM 1,674 226
Raised Floor Area: 0 (NE) 1,075 493
Slab on Grade Area: 5,874 (SE) 1,548 221
Average Ceiling Height: 12.4 Roof 5,874 0
Fenestration Average U -Factor: 0.45 TOTAL: 1,111
Average SHGC: 0.37 Fenestration/CFA Ratio: 18.9%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
All'��
3/18/1014
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that=compliance-using-duct design,
duct insulation installation building erivel'opd's,eealin
sealing, verification of refrigerant charge, qualitytiarid g 1eq
installer testing and certification and field verification by an approved HERSi1raterDING & SAFETY DEPT.
't
Designer or Owner (per Business & Professions Code)APPR®V 0
Company Helton, DeFord & Associates F C' NSTR N
Address 17411 Irvine Blvd., Suite O Name Jim Deford
I City/State/Zip Tustin, CA 92780 Phone (909) 957-4550 DATE igned Bir License # Date
EnerqyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2014 03-18 714 22:52 ID: Pa e 5 of 29
•
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Abel Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1311812014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame interiorl Frame Azm I Tilt Status 4 Location/Comments
Roof
1,264
0.026 R-38
270
0 New 4.2.1-A9
Master Suite
Wall
185
0.069 R-21
45
90 New 4.3.1-A6
Master Suite
Wall
58
0.069 R-21
135
90 New 4.3.1-A6
Master Suite
Wall
30
0.069 R-21
225
90 New 4.3.1-A6
Master Suite
Wall
605
0.069 R-21
315
90 New 4.3.1-A6
Master Suite
Slab
978
0.730 None
0
180 New 4.4.7-A1
Master Suite
Slab
286
0.730 None
0
180 New 4.4.7-A1
Master Suite
Roof
740
0.026 R-38
270
0 New 4.2.1-A9
Bedroom 2 & 3
Wall
159
0.069 R-21
135
90 New 4.3.1-A6
Bedroom 2 & 3
Wall
30
0.069 R-21
225
90 New 4.3.1-A6
Bedroom 2 & 3
Wall
321
0.069 R-21
315
90 New 4.3.1-A6
Bedroom 2 & 3
Slab
635
0.730 None
0
180 New 4.4.7-A1
Bedroom 2 & 3
Slab
105
0.730 None
0
180 New 4.4.7-A1
Bedroom 2 & 3
Roof
449
0.026 R-38
270
0 New 4.2.1-A9
Casita
well
50
0.069 1 R-21
45
90 New 14.3.1-A6
Casita
well
1661
0.069 R-21
135 1
90 New 14.3.1-A6
Casita
FENESTRATION SURFACE DETAILS
ID
Type I Area LI -Factor'
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
126.0 0.390 NFRC
0.36 NFRC
45 New
Double non-metal tinted
Master Suite
2
Window
10.0 0.390 NFRC
0.36 NFRC
45 New
Double non-metal tinted
Master Suite
3
Window
36.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Master Suite
4
Window
18.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Master Suite
5
Window
18.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Master Suite
6
Window
36.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Bedroom 2 & 3
7
Window
8.0 0.390 NFRC
0.36 NFRC
315 New
Double non-metal tinted
Bedroom 2 & 3
8
Window
36.0 0.390 NFRC
0.36 NFRC
315 New
Double non-metal tinted
Bedroom 2 & 3
9
Window
24.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Casita
10
Window
14.0 0.390 NFRC
0.36 NFRC
225 New
Double non-metal tinted
Casita
11
Window
18.0 0.390 NFRC
0.36 NFRC
225 New
Double non-metal tinted
Casita
12
Window
18.0 0.390 NFRC
0.36 NFRC
225 New
Double non-metal tinted
Casita
13
Window
8.0 0.390 NFRC
0.36 NFRC
315 New
Double non-metal tinted
Casita
14
Window
8.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Bedroom 4
15
Window
15.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Bedroom 4
16
Window
15.0 0.390 NFRC
0.36 1 NFRC
135 New
Double non-metal tinted
Bedroom 4
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76-
9
Bug Screen
0.76
1 U i I Y iz� I i1 n I I N I - .n
10
Bug Screen
0.76
M I�r, I►t ��, :�.
_ _
11
Bug Screen
0.76
- `'�` �; `�% �t 1 Y LCL FT N
12
Bug Screen
0.76
N IQ r i
13
Bug Screen
0.76
gr r*ir--
14
Bug Screen
0.76
I9Uu
I UN
15
Bug Screen
0.761
1
16
lBug Screen
0.761
1Q
r�
EnergyPro
5.1 Fy'EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 ID:
Page 6 of 29
1�
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Abel Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
3/18/2014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
210
0.069 R-21
225
90 New 4.3.1-A6
Casita
Wall
177
0.069 R-21
315
90 New 4.3.1-A6
Casita
Slab
386
0.730 None
0
180 New 4.4.7-A1
Casita
Slab
63
0.730 None
0
180 New 4.4.7-A1
Casita
Roof
320
0.026 R-38
270
0 New 4.2.1-A9
Bedroom 4
Wall
40
0.069 R-21
45
90 New 4.3.1-A6
Bedroom 4
Wall
222
0.069 R-21
135
90 New 4.3.1-A6
Bedroom 4
Wall
150
0.069 R-21
225
90 New 4.3.1-A6
Bedroom 4
Slab
274
0.730 None
0
180 New 4.4.7-A1
Bedroom 4
Slab
46
0.730 None
0
180 New 4.4.7-A1
Bedroom 4
Roof
3,101
0.026 R-38
270
0 New 4.2.1-A9
Great/Dining/Kitchen
Wall
307
0.069 R-21
45
90 New 4.3.1-A6
Great/Dining/Kitchen
Wall
722
0.069 R-21
135
90 New 4.3.1-A6
Great/Dining/Kitchen
Wall
306
0.069 R-21
225
90 New 4.3.1-A6
Great/Dining/Kitchen
Door
24
0.500 None
225
90 New 4.5.1-A4
Great/Dining/Kitchen
Wall
345
0.069 R-21
315
90 New 14.3.1-A6
Great/Dining/Kitchen
FENESTRATION SURFACE DETAILS
ID
Tvpe Area U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
17
Window
231.0 0.390 NFRC
0.36 1 NFRC
45 New
Double non-metal tinted
Great/Dining/Kitchen
18
Window
126.0 0.390 NFRC
0.36 NFRC
45 New
Double non-metal tinted
Great/Dining/Kitchen
19
Wndow
5.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Great/Dining/Kitchen
20
Window
5.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Great/Dining/Kitchen
21
Window
5.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Great/DiningAitchen
22
Window
18.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
Great/Dining/Kitchen
23
Window
18.0 0.390 NFRC
0.36 NFRC
135 New
Double non-metal tinted
GreatlDining/Kitchen
24
Window
115.0 0.950 NFRC
0.49 NFRC
225 New
Entry Door
Great/Dining/Kitchen
25
Window
6.0 0.390 NFRC
0.36 NFRC
225 New
Double non-metal tinted
GreatlDining/Kitchen
26
Window
18.0 0.390 NFRC
0.36 NFRC
315 New
Double non-metal tinted
Great/Dining/Kitchen
27
Window
108.0 0.390 NFRC
0.36 NFRC
315 New
Double non-metal tinted
Great/Dining/Kitchen
28
Window
48.0 0.390 NFRC
0.36 NFRC
315 New
Double non-metal tinted
Great/Dining/Kitchen
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len I H t Dist Len H t
17
Bug Screen
0.76
11.0 21.0
20.0 0.1
20.0 20.0
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
10.0 11.5
5.0 0.1
5.'O= -&0- -- -
_
25
Bug Screen
0.76
(:I I% p F l a n r�
26
Bug Screen
0.76
11.0 10.0
20.0 0.1
2d 0 20.-0,"
27
Bug screen
0.76
1 L.10`1"y"%Ju. T tl Y
28
Bug Screen
0.76
8.0 6.0
15.0 0.1
15.0 15:0; ? ! ; A r K--- r
1 3FY61;'UGTl DN
y1
I
�,.------_ BY
i5neflgyPro
5.1 by EnergySoft User Number: 6712 Run Code: 201403-18T14:22:52 ID:
Page 7 of 29
0
CE-RTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
Abel Residence
Building Type 0 Single Family
0 Multi Family
0 Addition Alone
0 Existing+ Addition/Alteration
OPAQUE
Joint Appendix
4 Location/Comments
FENESTRATION
.Standards,
...Standards,
.-
-.
:.
0
1�
17,
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Abel Residence
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
131181,2014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existinq Altered Removed Volume Year Built
HVAC 1 Master Suite
1,264
15,926
HVAC 2 Bedroom 2 & 3
740
7,400
Casita
449
4,490
HVAC 3 & 4 Bedroom 4
320
3,200
Great/Dining/Kitchen
3,101
41,864
Totals 5,874 0 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 1 Central Furnace
80% AFUE Split Air Conditioner 16.5 SEER Setback
New
HVAC 2 1 Central Furnace
80% AFUE Split Air Conditioner 16.5 SEER Setback
New
HVAC 3 & 4 2 Central Furnace
80% AFUE Split Air Conditioner 16.5 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
m New
HVAC 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
® New
HVAC 3 & 4 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
D New
WATER HEATING SYSTEMS
S stem Name
Qty-
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White 75 Gal
2
Small Gas
All Pipes Ins
65,000
75
0.65
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
I HYDRONIC-HEATIN_
G SYSTEM PIPING
Control
Hot Water Piping Length
ft
.
N
a
I Y OFLA - —
ETY� A
BUILDIIi4C &QuipSAf
i P-ipe®Pip
4EWO�11e Vit) Diam ter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
❑
4- Iwo IN1 JCTIOA
❑'UHE
Ene Pro 5.1 by EnergySoft User Number: 6712
RunCode: 2014-03-18714:22:52 ID:
Page 9 of 29
r
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
Abel Residence
3/18/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
i R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
1§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
e ui ed with a with a readilyaccessible operable, and ti ht-fittin damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinq sections of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15,psi, meets the requirements of Standards Table
123-A. I r-% c r , „_ —
150 ' 3A: Insulation is protected from damage, including that due to sunlight! mo"iAura a ui menlN° a ntenancei�and,w)nd!
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a-vap"or�refa�dan4=o.P�isen�cfgsedZetirely in
conditioned space. n +-+ rte. r-+ ,.—
§150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Ratin ,andlCertif cation Q6r oration.
r
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-18,T14:22:52 1D:— By Page 10 of 29
4
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
bel Residence
1311812014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
4150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
4150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor. T__'�_ —
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no' more than.20 watts of power per linear foot
6f
illuminated cabinet.
�._ �•..w ca .�ryr Lz
Full CCINSTnUCTiON
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2014-03-18T14.,22:52:.- _ _^ ID: age 11 of 29
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name Date
Abel Residence 1311812014
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)l 1: Permanently. installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146.
§150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APF ROWED
FOR CONSTRUCTION
DATE BY
1:En,:,T:g:y:P::m 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18T14:22:52 - ID: Page 12 of 29
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
0.0 %
Project Name
bel Residence
1,059
Aug 3 PM
89,000
Outside Air cfm/s K 0.00
Vote: values above given at ARI conditions
Date
3/18/2014
System Name
HVAC 1
(Airstream Temperatures at Time of Heating Peak)
26 OF
72 OF
Floor Area
1,264
ENGINEERING CHECKS
110
SYSTEM LOAD
Outside Air
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
596
0
COOLING PEAK
°
123 F
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem 89,000
13,354
1,815
261
14,263
Total Output Stuh 89,000
0
Output Btuhls ft 70.4
771
701
Cooling System
0
0
Output perSystem 49,000
0
0
0
0
Total Output Btuh 49,000
0
1,815
0
Total Output Tons 4.1
1 771
701
Total Output Btuh/s ft 38.8
Total Output s ft/Ton 309.6
1 14,896
1 15,665
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
24ANB748/58CVX090
37,405 1,059
89,000
Airflow cfm/s ft
1.27
Airflow cfm/Ton 391.8
Outside Air %
0.0 %
Total Adjusted System Output 37,405
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK
1,059
Aug 3 PM
89,000
Outside Air cfm/s K 0.00
Vote: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
72 OF
124 OF 124 OF
110
--
f
Outside Air
0 cfm
Heating Coil Supply Fan
°
123 F
1,600 cfm
ROOM
72 OF
.4 -dieo-
72 OF
1
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 70/57°F 48/47°F 48/47°F
UG
_ gyp_Outside AirAr
Su I Fan r OF LA QUIN] `���°
0 cfm Cooling Coil Supply 49 4 F
1,600 cfm BUILDING & S!-\ �TV f1��e�j
A P PI -°70 � 9 A OI�OIYI
70 157 OF
FOR CONSTRUCTION 70/5 OF
D.aTE BY
EneravPro 5.1 by EnerovSoff User Number: 6712 RunCode: 2014-03-18T14:22:52 /D: age 13 of 29
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
bel Residence
Date
3/18/2014
System Name
HVAC 2
Floor Area
1,189
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 1
COIL
CFM
Total Room Loads 544
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 89,000
12,199
1,920 277
15,175
Total Output Btuh 89,000
0
Output Btuh/s ft 74.9
704
746
Cooling System
0
0
Output per System 49,0001
0
0 0
0
Total Output Btuh 49,000
0
1,920
0
Total Output Tons 4.1
1 04
746
Total Output Btuh/s ft 41.2
Total Output s ft/Ton 291.2
13,608
16,667
Air System
CFM per System 1,600
HVAC EQUIPMENT SELECTION
Alrflow cfm 1,600
24ANB748/58CVX090 37,307 1,169
89,000
Airflow cfm/s ft 1.35
89,000
Jan 1 AM
Airflow cfm[Ton 391.8
Outside Air % 0.0%
Total Adjusted System Output 37,307 1,169
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF 124 OF 124 OF
0
Outside Air
0 cfm Heating Coil Supply Fan
123 OF
1,600 cfm
ROOM
72 OF 72 OF
1
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
J:E:,�ergy�P::ro5.1
112/78°F 70/57°F 49/47°F 49/47°F
Outside Air /� ^i �
Supply Fan �"'� y V F LA Q J l 49, 48 F
0 cfm CoolingCoil 1,600 cfm BUILDING � C Y
4"4'4% p RO
��FTY,[,P
APF-r!U��
70 / 57 OF FOR CONSTRUCTION 70/5 OF
D.aTE �_ gY
by EnergySoff User Number: 6712 RunCode: 2014-03-18714:22:52 /D: a 14 of 29
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
Abel Residence 3/18/2014
System Name Floor Area
HVAC 3 & 4 3,421
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 2 COIL COOLING PEAK COIL HTG. PEAK
Heating System CFM Sensible Latent CFM Sensible
Output per System 89,000 Total Room Loads 2,278 42,833 4,772 1,072 46,484
Total Output Btuh 178,000 Return Vented Lighting 0
Output Btuh/s ft 52.0 Return Air Ducts 2,473 2,285
Cooling System Return Fan 0 0
Output per System 58,000 Ventilation 0 0 0 0 0
Total Output Btuh 116,000 Supply Fan 0 0
Total Output Tons 9.7 Supply Air Ducts 2,473 1 2,285
Total Output Btuh/s ft 33.9
Total Output s f rron 353.9 TOTAL SYSTEM LOAD 1 47,779 4,772 51,053
Air System
CFM per System 2,000 HVAC EQUIPMENT SELECTION
Airflow cfm 4,000 24ANB760/58CVX090 80,151 13,302 178,000
Airflow cfm/s ft 1.17
Airflow cfm/Ton 413.8
Outside Air % -0.0% Total Adjusted System Output 80,151 13,302 178,000
Outside Air cfm/s ft 0.00 (Adjusted for Peak Design conditions)
Note: values above given at ARI conditions 1 TIME OF SYSTEM PEAK Aug 3P MJan 1 AM
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 OF 71 OF 113 OF 113 OF
Outside Air
0 cfm Heating Coil Supply Fan °
113 F
4,000 cfm
ROOM In
71 OF 72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 71/59°F 52/51°F 52!51°F
0
Outside Air c
O cfm Cooling Coil Supply Fan C I I T G F 1 /t U NT q;5�21 51 °F
4,000 cfm gl�®1NG �—�1 /`1
50.°��iFE__OOM.
P��V�� 70/59°F
71 ! 59 °F +-[ FOR CONSTRUCTION
DATE.__ BY
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201403-18T14:22:52: ID: ,Page 15 of 29
•
r�
L J
ROOM LOAD SUMMARY
Project Name
Abel Residence
Date
3/18/2014
System Name
HVAC 1
Floor Area
1,264
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Master Suite Master Suite
1 596 13,354 1,815 596 13,354 1,815 261 14,263
A Q IIN, rr A.1
I RI 11 nlNi(� P. QA 7r: rer- r
IA r", r,�e-v1 B�rw
' Total includes ventilation load for zonal systems.
m Y "..,d VC-- LJ
PAGE TOTAL rv596� '��1F3 354 jL%�1%815 �N 261 14,263
TOTAL' 596 13,354 1,815 261 14,263
DATE gY
EneMyPro 5.1 by EneMySoft User Number: 6712
RunCode: 2014-03-1 8 714:22:52 1'D: P e 16 of 29
•
ROOM LOAD SUMMARY
Project Name Date
Abel Residence 3/1812014
System Name Floor Area
HVAC 2 1,189
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible
Bedroom 2 & 3 Bedroom 2 & 3 1 293 6,574 1,146 293 6,574 1,146 143 7,805
Casita Casita 1 1 2511 5,625 774 251 5,6251 774 135 7,370
I'T
Frr i art' '/'T'0N277 15,175
PAGE TOTAL 544' C�12�199 R�1�,920 i
TOTAL' 1 5441 12,199 1,920 277 1 15,175
DATE BY
•
17,
ROOM HEATING PEAK LOADS
Project Name73/18/2014
Abel Residence
ate
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Floor Area 1,264.0 ft2
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
46 =
46 =
46 =
46 =
=
=
=
=
=
=
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Rage Total
L �k
GAFF i46,
��A-T_vFraction �6L=oS ijr-TIONI
Btu/hr
R-38 Roof(R.38.2x14.16)
1,264.0
0.0260
1,512
R-21 Wall (W 19.2x6.16)
878.0
0.0690
2,787
Double non-metal tinted
208.0
0.3900
3,732
Slab -On -Grade
perim = 88.0
. 0.7300
2,955
another roomF,&
12.60 X;
Height
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
through an interior surface
1.064 X 1,264 X
Area
10,985
u`ra . 3,w 78
TOTAL HOURLY HEAT LOSS FOR ROOM 14 P-631
DATE BY
Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-1 8 714:22:52 -iD: eage 19 f 29
•
L_ I
ROOM HEATING PEAK LOADS
Project Name
Abel Residence
Date
3/18/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2 & 3
Floor Area 740.0 ft2
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
-
=
=
=
Btu/hr
R-38 Roof(R.38.2x14.16)
740.0
0.0260
46
885
R-21 Wall (W.19.2x6.16)
510.0
0.0690
46
1,619
Double non-metal tinted
80.0
0.3900
46
1,435
Slab -On -Grade
penim = 58.0
0.7300
46
1,948
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X F____1
Schedule Air Sensible
Fraction
through an interior surface
064 X 740 X
Area
another room
10. �0 X-n3i
Page Total
1 5,887
- 1,919
oWD J_J( QU1M�
& SAFETY
OV
DEPT.
Ceiling
Heigh BUIAMING
^^
APP
i TOTAL HOURLY HEAT LOSS FOR ROOM i FOR CoNsTRucTinN7 805
EnefgyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18T14:22: 2A I E —!Q: BY Pa 20 of 29
•
•
ROOM HEATING PEAK LOADS
Project Name73/18/2014
Abel Residence
ate
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 449.0 ft'
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
QTY
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
-_6
QUtNTP.
e�
Btu/hr
R-38 Roof(R.38.2x14.16)
449.0
0.0260
46
537
R-21 Wall (W.19.2x6.16)
603.0
0.0690
46
1,914
Double non-metal tinted
82.0
0.3900
46
1,471
Slab -On -Grade
penim = 68.0
0.7300
46
2,283
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
1.064 X 449 X
Area
another roomF
10.00 X
Height
0?3.118
Total
OA
LA
_f0i]a XkSAFE96EPT.1,s4
iY AT
CONSTRUCTION
205
ACH
I
FOR
TOTAL HOURLY HEAT LOSS FOR ROOM
7 3;70
DATE BY
Energ Pro 5.1 6 Ene Soft User Number. 6712 RunCode: 2014-03-18714:22:52 ID: Page 29 -of 29
•
ROOM HEATING PEAK LOADS
Project Name
Abel Residence
Date
3/18/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 4
Floor Area 320.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
-V81
AT *F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
�46]
TY
Btu/hr
R-38 Roof(R.38.2x14.16)
320.0
0.0260
46
383
R-21 Wall (W. 19.2x6.16)
412.0
0.0690
46
1,308
Double non-metal tinted
38.0
0.3900
46
682
Slab -On -Grade
perim = 41.0
0.7300
46
1,377
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
1.064 X 320 X
Area
another room �y --
10.00 X O
Height ACH
I
Page Total
� Ir
®60.; X I --k
NU & 6NY
APPROVED'
1 3,749
i �e
t=�� 1A 830
DEPT.
I
TOTAL HOURLY HEAT LOSS FOR ROOM I rUh UUIN6 1 HUCTION 4 679
1 nnrr - L
—
6nergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 1 /D.- -Ra e_2 129
C7
174
ROOM HEATING PEAK LOADS
Project Name7311812014
Abel Residence
ate
ROOM INFORMATION
DESIGN CONDITIONS
Room Name GreabDining/Kitchen
Floor.Area 3,101.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FOR
AT OF
Btu/hr
R-38 Roof(R.38.2x14.16)
3,101.0
0.0260
46
=
3,709
R-21 Wall (W. 19.2x6.16)
1,680.0
0.0690
46
=
5,332
Double non-metal tinted
588.0
0.3900
46
=
10,549
Entry Door
115.0
0.9500
46
=
5,026
Wood Door
24.0
0.5000
46
=
552
Slab -On -Grade
perim = 259.0
0.7300
46
=
8,697
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
•
=
=
=
=
Items shown with an asterisk (') denote conduction
Infiltration: 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
X 3,101 X
Area
another room
CITY
13.50 X t0�2F35
Height
Page -Total=
OF LA Qx
/I60�� 4-X JAFET4,6I=[:p
®rQT,
ED
CONSTRUCTION
--®3.3, 865
Ifel
8041
TOTAL HOURLY HEAT LOSS FOR ROOM 1 41 905
LI DATE —� BY
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-18714:22:52 /D: age -2 f 29
:7
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7311812014
ate
Abel Residence
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,264.0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OFI
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) (W) 1,264.0 X
0.0260 X 56.0 =
1,840
R-21 Wall (W 19.2x6.16) (NE) 185.0 X
0.0690 X 29.0 =
370
R-21 Wall (W. 19.2x6.16) (SE) 58.0 X
0.0690 X 31.0 =
124
R-21 Wall (W. 19.2x6.16) (SW) 30.0 X
0.0690 X 31.0 =
64
R-21 Wall (W.19.2x6.16) (NW) 605.0 X
0.0690 X 30.2 =
1,262
X
X =
X
X =
X
X =
X I
X I=
Page Total
3,661
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btu/hr
1D (NE) 0.0 X 21.2
+ 126.0 X 32.7 =
4,125
113 (NE) 0.0 X 21.2
+ 10.0 X 32.7 =
327
110 (SE) 0.0 X 21.2
+ 36.0 X 29.4 =
1,060
111 (SE) 0.0 X 21.2
+ 18.0 x 29.4 =
530
112 (SE) 0.01 X 21.2
+ 18.0 X 29.4 =
530
X
+ X =
X
+ X -
X
+ X -
X
+1 1 X =
Page Total
6,572
Internal Gain
Btu/hr
Occupants 1.0 Occupants X
230 Btuh/occ. =
EA
Equipment 0.0 Dwelling Unit X
1,600 Btu =
Infiltration: 1.064 x 0.94 X 69.17 X 42 =
2,891
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,354
Latent Gain
CITY OF LA QUIN
,Btu hr
Occupants 1.0 Occupants X i
t' 41061 Bt�u`h 6A.SAFETy p
200
A'�POVED
Infiltration: 4,771 x 0.94 x 69.17 x 0.00523 =
FOR CONSTRUCTION
1,615
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM "~' ---- BY
1,815
EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2014-03-18714:22:52
/D:
Page 24 of 29
C
C
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Abel Residence
1 3118/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2 & 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area 740.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area
U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) (M 740.0 X
0.0260 X 56.0 =
1,077
R-21 Wall (W.19.2x6.16) (SE) 159.0 X
0.0690 X 31.0 =
340
R-21 Wall (W.19.2x6.16) (SVt9
30.0 X
0.0690 X 31.0 =
64
R-21 Wall (W..19.2x6.16) (NVt9 321.0 X
0.0690 X 30.2 =
670
X
X =
X
X =
X
X =
X
X =
X
X I=
Page Total
2,151
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area
GLF
Area GLF
Btu/hr
103 (SE)
0.01 X 21.2
+ 36.0 X 29.4 =
1,060
108 (NVV)
0.0 X 21.2
+ 8.0 X 32.7 =
262
109 (NVt9
0.0 X 21.2
+ 36.0 X 32.7 =
1,178
X
+ X -
X
+ X -
X
+ X -
X
+ X -
X
+ X -
X
+1 X -
Page Total
2,500
Internal Gain
Btu/hr
Occupants 1.0 Occupants X
230 Btuh/occ. =
230
Equipment 0.0 Dwelling Unit X
1,600 Btu =
0
Infiltration: 1.064 X 0.94 X 40.49 X 42 =
1,693
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
6,574
Latent Gain
1
V,�
F L QJ 1 tll/hr00
Occupants 1.0 Occupants X
OO�Btuh/o "`
---Ullqu & SAFETY DEPT
Infiltration: 4,771 X 0.94 X 40.49 X 0.00523 =
APPROVE
946
Air Sensible CFM ELA
AW
FOR CONSTRUCTION
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
T�
1 146
Ener Pro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2014-03-18T14:22:52
ID: a e,2 f 29
•
C
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Abel Residence
1 3/18/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 449.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) (tM 449.0 X 0.0260 X 56.0 =
654
R-21 Wall (W 19.2x6.16) (NE) 50.0 X 0.0690 X 29.0 =
100
R-21 Wall (W. 19.2x6.16) (SE) 166.0 X 0.0690 X 31.0 =
355
R-21 Wall (W. 19.2x6.16) (Stns 210.0 X 0.0690 X 31.0 =
449
R-21 Wall (W.19.2x6.16) (NW) 177.0 X 0.0690 X 30.2 =
369
X X =
X X =
X X =
X I X =
Page Total 1
1,927
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area GLF
Btu/hr
1B (SE) 0.0 X 21.2 + 24.0 X 29.4 =
707
104 (SW) 0.0 X 21.2 + 14.0 X 29.4 =
412
105 (SW) 0.0 X 21.2 + 18.0 X 29.4 =
530
106 (SW) 0.0 X 21.2 + 18.0 X 29.4 =
530
107 (NW) 0.01 X 21.2 + 8.0 X 32.7 =
262
X + X -
X + X -
X + X -
X +1 X -
Page Total
2,441
Internal Gain
Btu/hr
Occupants 1.0 Occupants X 230 Btuh/occ. =
230
Equipment 0.0 Dwelling Unit X 1,600 Btu =
0
Infiltration: 1.064 X 0.94 X 24.57 X 42 =
1,027
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
5,625
Latent Gain
Btu/hr
j
Occupants 1.0 Occupants X . '200 lBtuh/o cc F LLIAJ Q UU INT, '00
`RUILtDIIvC &SAFETY
Infiltration: 4,771 X 0.94 X 24.57 X 0.00523 = APPROVE
74
Air Sensible CFM ELA ow
FOR CONSTRUCTION
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
74
DATE
EnerqvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2014-03-18T14:22:52L ----ID
29
•
4
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Abel Residence
1 3/18/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area 320.0 ft-'
Outdoor Wet Bulb
Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area
U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) (W) 320.0 X 0.0260 X 56.0 =
466
R-21 Wall (W.19.2x6.16) (NE)
40.0 X 0.0690 X 29.0 =
80
R-21 Wall (W.19.2x6.16) (SE) 222.0 X 0.0690 X 31.0 =
475
R-21 Wall (W.19.2x6.16) (SW) 150.0 X 0.0690 X 31.0 =
321
X
X =
X
X =
X
X =
X
X =
X
J X I_
Page Total
1,342
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area
GLF
Area GLF
Btu/hr
117 (SE)
0.0 X 21.2 + 8.0 X 29.4 =
236
118 (SE)
0.0 X 21.2 + 15.0 X 29.4 =
442
119 (SE)
0.0 X 21.2 + 15.0 X 29.4 =
442
X + X -
X + X -
X + X =
X + X =
X + X -
X +1 X =
Page Total
1,119
Internal Gain
Btu/hr
Occu ants 1.0 Occupants X
230 Btuh/occ. =
230
Equipment 0.0 Dwelling Unit X
1,600 Btu =
0
Infiltration: 1.064 X 0.94 X 17.51
X 42 =
732
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
3,423
Latent Gain
Btu/hr
Occupants 1.0 Occupants X
r-200 -Btuh/occ:
CITY OF L QUINITA
Infiltration: 4,771 X 0.94 X 17.51 X 0.00523 =
BUILDING & SAFETY
4 9
Air Sensible CFM ELA
AW
APPROVED
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
t -UH (.. IV5 I HUG I IO
g g
M
EnB Pro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2014-03-18714:22:52
I . ID: Page 27 of g.9
•
•
I
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name73/18/2014
ate
Abel Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name GreatlDining/Kitchen Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,101.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF
Or)aaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. -19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W19.2x6.16)
Wood Door
R-21 Wall (W. 19.2x6.16)
Orientation
(SE)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
3,101.0
0.0260
56.0
307.0
0.0690
29.0
722.0
0.0690
31.0
306.0
0.0690
31.0
24.01
0.5000
31.0
345.0
0.0690
30.2
21.2
18.0
29.4
0.0
85.7
21.2
18.0
29.4
37.2
29.3
48.5
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area GLF
1E
1G
114
115
116
101
102
1A
100
I Internal Gain
(NE)
(NE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SM
(SM
0.0
X
X
X
X
X
X
X
X
X
21.2
+
+
+
+
+
+
+
+
+
231.0
X
X
X
X
X
X
X
X
X
32.7
=
=
=
=
=
=
=
=
=
0.0
21.2
126.0
32.7
0.0
0.0
21.2
5.0
29.4
21.2
5.0
29.4
0.0
21.2
5.0
29.4
0.01
21.2
18.0
29.4
0.0
85.7
21.2
18.0
29.4
37.2
29.3
48.5
0.0
21.2
6.0
29.4
Page Total
Btu/hr
4, 515
614
1, 544
Btu/hr
7,562
4,125
147
147
147
530
530
4,607
177
17,972
Occupants 1.0 Occupants X 230 Btuh/occ. = 230
Equipment 0.0 Dwelling Unit X 1,600 Btu = 0
Infiltration: 1.064 X 0.94 X 169.69 X 42 = 7,093
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39.411
Latent Gain
Occupants 1.0 Occupants X
Infiltration: 4,771 X 0.94 X 169.69 X 0.00523 =
Air Sensible CFM ELA AW
AL HOURLY LATENT HEAT GAIN FOR ROOM
ITY OF LA Q
31UOoccG & SAFE
r-1
FOR CONSTRUC
3,
r �
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Abel Residence
7
3/18/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
GreabDining/Kitchen
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,101.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area
U -Factor
CLTD'
Btu/hr
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total 1
0
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area
GLF
Area GLF
Btu/hr
121
(NM
0.0 X 21.2 +
18.0 X 32.7
= 589
1 M
(NV10
0.0 X 21.2 +
108.0 X 32.7
= 3,535
1F
(NIM
0.0 X 21.2 +
48.0 X 32.7
= 1,571
X +
X
–
X +
X
–
X +
X
=
X +
X
=
X +
X
–
X +
X
–
Page Total
5,696
Internal Gain
Btu/hr—
tu/hrOccu
Occupants
ants
1.0 Occupants X
230
Btuh/occ. =
230
Equipment
0.0 Dwelling Unit X
1,600
Btu =
0
Infiltration: 1.064
X 0.94 .X 169.69 X 42 =
7,093
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
39,411
Latent Gain
Btu/hr
Occupants
1.0 Occupants X
2 �0
pp
UhT I®F LAI
BUILDIiVGTA
AFES
Infiltration: 4,771
X 0.94 X 169.69
X 0.00523 =
es
Q 3
Air Sensible
CFM ELA
OW
PP
FOR OVED
V4
C�
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
163
DAT
EnemvPro 5.1 by EnerqvSoft
User Number: 6712 Run Code: 2014-03-18T14:22:52 L–I -
Y
Page 29 of 29