13-0380 (SFD) Title 24E
•
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Duffield Residence
78-331 Deacon Drive Lot 14
La Quinta, CA 92253
Project Designer:
Design Mind Studios
74-794 42nd Ave, Suite 9
Palm Desert, Ca 92211
(760) 773-4488
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
• 77-085 Michigan Drive
Palm Desert, CaF 1•.-A Qvi EpT,
(760) 200-47 0C p1® & Sp'FET`( D
RpR®vE®�
F4R CpN
S�
I
Date: MAY 15 2013
5/10/2013 CITY OF 1A QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 ID:
r==
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1R Mandatory Measures Summary 11
HVAC System Heating and Cooling Loads Summary 14
Room Load Summary 18
Room Heating Peak Loads 22
Room Cooling Peak Loads 26
•
CITY 0-17 LA QUINTA
E?11js_D& SAFETY DEPT.
APPROVE®
FOR CONSTRUCTIn^'
EneravPro 5.1 by Energvsoft Job Number: ID: I BATE User NL"mbev-6712
•
:7
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Duffield Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 1511012013
Date
Project Address
78-331 Deacon Drive Lot 14
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,637
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity ( Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 4,634 Radiant Barrier New
Wall Wood Framed
R-21 4,531 New
Slab Unheated Slab -on -Grade
None 4,637 Perim = 485' New
Door Opaque Door
None 48 New
FENESTRATION
Orientation Area
U- Exterior
Factor SHGC Overhang Sidefins Shades Status
Skylight 1.4
0.300 0.30 none none None New
Rear (N) 480.0
0.460 0.39 none none Bug Screen New
Right (SE) 101.6
0.460 0.39 none none Bug Screen New
Left (WJ 335.0
0.460 0.39 none none Bug Screen New
Skylight 1.4
0.300 0.30 none none None New
Front (S) 146.7
0.460 0.39 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback New
1 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback New
1 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
HVAC 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
HVAC 3 Ducted
Ducted Attic, Ceiling Ins, vented _._ �:0 New
WATER HEATING
Ot . Type
Q� --L 4, UJIN
Gallons Min. Eff FDstri';bt�tion s c; o =E -(Y DEPT. , tatus
1 Large Gas
100 0.99 1 Arl:Pipes Ins., , .. ; , ; P New
liiTION
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013 -05 -10T09;44:09 ----ID=—
Page 3 of 29
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Duffield Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 1511012013
Date
Project Address
78-331 Deacon Drive Lot 14 La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,637
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 17:7 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING , �; !!\ QUINTI A itatus
Ot . T e Gallons Min. Eff Distribution , .. , -,-„ nl`P
■
N
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09:44:00.: ID:
Pa e 4 of 29
•
0
L I
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Building Type ® Single Family ❑ Addition Alone
Date
Duffield Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
5/10/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Bradford -White #MN-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 667.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom
HIGH MASS Design - Verify Thermal Mass: 620.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom
The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 34 1. 0 ft' Covered Slab Floor, 3.500" thick at Gallery Entry Office
HIGH MASS Design - Verify Thermal Mass: 826.0 ft2 Exposed Slab Floor, 3.500" thick at Gallery Entry Office
The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the airflow requirements and fan waft draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass 436.0 ft2 Covered Slab Floor, 3.500" thick at Living Greatroom
HIGH MASS Design - Verify Thermal Massa 1, 090.0 ft2 Exposed Slab Floor, 3.500" thick at Living Greatroom
The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 275.0 ft2 Covered Slab Floor, 3.500" thick at Casita
HIGH MASS Design - Verify Thermal Mass: 382.0 ft2 Exposed Slab Floor, 3.500" thick at Casita
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Carrier 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB736156CVX090 includes credit for a 13.7 EER f3IE —rater must d veri the installation
�Conden-sgr—A.certified
of the correct Condenser. } r % IT! � �\ ���
The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge ora Charge Indicator
t rispley.
PU1'_�f
The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnosticttesting is"regdired to vet that duct
leakage meets the specified criteria.
EnemyPro 5.1 by Enem YSoft User Number., 6712 RunCode: 2013-05-10709:44:00 ID: RY Page 5 of 29
UH1���
0
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Duffield Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/10/2013
'SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
� T
CITY CM- ! YY
... ir- Q. L F TY DEPT.
FOR
ID:
Enem-Pro5.1 b Ene Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Pa e 6 of 29
IDATE ---- BY
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Duffield Residence
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
5/10/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2 r
Space Heating 4.50 4.27 0.23
Space Cooling 59.84 53.10 6.74
Fans 11.96 16.26 -4.30
Domestic Hot Water 7.87 4.27 3.59
Pumps 0.00 0.00 0.00
Totals 84.17 77.90 6.27
Percent Better Than Standard: 7.4%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 1,274 147
Fuel Available at Site: Natural Gas (W 1,646 335
Raised Floor Area: 0 (N) 1,160 480
Slab on Grade Area: 4,637 (E) 1,562 102
Average Ceiling Height: 11.8 Roof 4,637 3
Fenestration Average U -Factor: 0.46 TOTAL: 1,066
Average SHGC: 0.39 Fenestration/CFA Ratio: 23.0
REMARKS
Traditions Country Club lot 14
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and compiete.
Documentation Author
Company Scott Design and Title 24, Inc,
5/10/2013
JA�
Address 77-085 Michigan Drive Name Tim Scott
Citv/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
A UINTA
Company Design Mind Studios i A"- �-
D
Address 74-794 42nd Ave, Suite 9 Name Gordon Stein ;-Jii_ r'ti`�g, �r "
114111
t
City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-4488 AP�' ed -� n # ate
F - RUC
EnemvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: a e 7 of 29
•
•
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Duffield Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/10/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavit7yExterior Frame Interiorl Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Roof
1,286
0.026 R-38
0
20 New 4.2.1-A9
Master Bedroom
Wall
130
0.069 R-21
0
90 New 4.3.1-A6
Master Bedroom
Wall
665
0.069 R-21
135
90 New 4.3.1-A6
Master Bedroom
Wall
189
0.069 R-21
180
90 I New 4.3.1-A6
Master Bedroom
Wall
80
0.069 R-21
270
90 New 14.3.1-A6
Master Bedroom
Slab
667
0.730 None
0
180 New 4.4.7-A 1
Master Bedroom
Slab
620
0.730 None
0
180 New 4.4.7-A1
Master Bedroom
Roof
1,166
6.026 R-38
0
20 New 4.2.1-A9
22Ln Entry Office
We
306
0.069 R-21
135
90 New 4.3.1-A6
Gallery Entry Office
Door
24
0.500 None
135
90 New 4.5.1-A4
Gallery Entry Office
Wall
362
0.069 R-21
180
90 New 4.3.1-A6
Gallery Entry Office
Wall
363
0.069 R-21
270
90 New 4.3.1-A6
Gallery Entty Office
Slab
341
0.730 None
0
180 New 4.4.7-A1
Galle Ent Office
Slab
826
0.730 None
0
180 New 4.4.7-A1
GalleryEnt Office
Roof
1,526
0.026 R-38
0
20 New 4.2.1-A9
Livin Greatroom
Wall
372
0.069 R-21
0
90 New 4.3.1-A6
Livin Greatroom
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments-
1
Skylight
1.4 0.300 NFRC
0.30 NFRC 0 New
Solatube Skylight
Master Bedroom
2
Window
100.0 0.460 NFRC
0.39 NFRC 0 New
Architectural Windows
Master Bedroom
3
Window
6.0 0.460 NFRC
0.39 NFRC 135 New
Architectural Windows
Master Bedroom
4
Window
49.0 0.460 NFRC
0.39 NFRC 135 New
Architectural Windows
Master Bedroom
5
Window
9.0 0.460 NFRC
0.39 NFRC 135 New
Architectural Windows
Master Bedroom
6
Window
30.0 0.460 NFRC
0.39 NFRC 135 New
Architectural Windows
Master Bedroom
7
Window
15.0 0.460 NFRC
0.39 NFRC 270 New
Architectural Windows
Master Bedroom
8
Skylight
1.4 0.300 NFRC
0.30 NFRC 0 New
I Solatube Skylight
Gallery Entry Office
9
Window
5.3 0.460 NFRC
0.39 NFRC 180 New
Architectural Windows
Gallery Entry Office
10
Window
32.0 0.460 NFRC
0.39 NFRC 180 New
Architectural Windows
Gallery Entry Office
11
Window
80.0 0.460 NFRC
0.39 NFRC 270 New
Architectural Windows
Gallery Entry Office
12
Window
80.0 0.460 NFRC
0.39 NFRC 270 New
Architectural Windows
Gallery Entry Office
13
Window
80.0 0.460 NFRC
0.39 NFRC 270 New
Architectural Windows
Gallery Entry Office
14
Window
120.0 0.460 NFRC
0.39 NFRC 0 New
Architectural Windows
Living Greatroom
15
Window
180.0 0.460 NFRC
0.39 NFRC 0 New
Architectural Windows
Living Greatroom
16
Window
65.1 0.460 NFRC
0.39 NFRC 180 New
I Architectural Windows
Living Greatroom
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len I
Ri ht Fin
H t Dist Len H t
1
None
1.00
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
None
1.00
9
Bug Screen
0.76
10
_Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
�� - _
ilk VA I
13
Bug Screen
0.76
t -T
14
Bu Screen
0.76
• Ca
P[= e D
15
Bug Screen
0.76
16
IBug Screen
1 0.761
1
1 WT -3- 757P-
r"My
S7FRIJCTION
FOR 60-N-
EnergyPro
5.1 by EnergySoft User Number: 6712
RunCode: 2013-05-10709:94:00 ID:
Pa • e 8 of 29
0
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Duffield Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1511012013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavit7yExterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Wall
68 0.069 R-21
135 90 New 4.3.1-A6
Living Greatroom
Door
24 0.500 None
135 90 New 4.5.1-A4
Living Greatroom
Wall
363 0.069 R-21
180 90 New 4.3.1-A6
Living Greatroom
Wall
487 0.069 R-21
270 90 New 4.3.1-A6
Living Greatroom
Slab
436 0.730 None
0 180 New 4.4.7-A1
Living Greatroom
Slab
1,090 0.730 None
0 180 New 4.4.7-A1
Living Greatroom
Roof
657 0.026 R-38
0 20 New 4.2.1 A9
Casita
Wall
178 0.069 R-21
0 90 New 4.3.1-A6
Casita
Wall
373 0.069 R-21
135 90 New 4.3.1-A6
Casita
Wall
214 0.069 R-21
180 90 New 4.3.1-A6
Casita
Wall
381 0.069 R-21
270 90 New 4.3.1-A6
Casita
Slab
275 0.730 None
0 180 New 4.4.7-A I
Casita
Slab
382 0.730 None
0 180 New 4.4.7-A1
Casita
FENESTRATION SURFACE DETAILS
ID
Type Area U -Factor SHGC
Azm Status Glazing Type
Location/Comments
17
Window 80.0 0.460 NFRC 0.39 NFRC 270 New Architectural Windows
Living Greatroom
18
Window 80.0 0.460 NFRC 0.39 NFRC 0 New Architectural Windows
Casita
19
Window 3.8 0.460 NFRC 0.39 NFRC 135 New Architectural Windows
Casita
20
Window 3.8 0.460 NFRC 0.39 NFRC 135 New Architectural Windows
Casita
21
Window 5.3 0.460 NFRC 0.39 NFRC 180 New Architectural Windows
Casita
22
Window 39.0 0.460 NFRC 0.39 NFRC 180 New Architectural Windows
Casita
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hat Wd
Ove hang Left Fin Right Fin
Len Hot LExt RExt Dist Len Hat Dist Len Hot
17
Bug Screen 0.76
18
Bug Screen 0.76
19
Bug Screen 0.76
20
Bug Screen 0.76
21
Bug Screen 0.76
22
Bug Screen 0.76
tw
"�" .YDI1.
EnergyPro
5.1 by EnerqySoft User Number.- 6712
RunCode: 2013-05-10709:44:00 _ ID: BY a 9 of 29
0
�J
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CFA R
Project Name
Duffield Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1511012013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existinq Altered Removed Volume
Year Built
HVAC 1 Master Bedroom
1,287
14,929
HVAC 2 Gallery Entry Office
1,167
13,537
HVAC 3 Living Greatroom
1,526
19,228
HVAC 4 Casita
657
7,227
Totals 4,637 0 01 0
HVAC SYSTEMS
System Name Qty.. Heating Type
Min. Elf. Cooling Type Min. Eff. Thermostat Type
Status
HVAC 1 1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC 2 1 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC 3 1 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC 4 1 Central Furnace
80% AFUE S lit Air Conditioner 17.7 SEER Setback
New
HVAC DISTRIBUTION
System Name Heatina
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0
m
New
HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0
m
New
HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented i 8.01
New
HVAC 4 1 Ducted I Ducted JAttic, Ceiling Ins, vented 1 8.01
EI
New
WATER HEATING SYSTEMS
S stem Name
Oty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White #MN -1-100
1
Large Gas
All Pipes Ins
85,000
100
0.99 0.00%
0.0
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM PIPING
Control
Hot Water Piping Length
n
0
75ro
v,�ipe—
a —
rr S stem ame, _
,Lengthl
I JQiaTearThick.
Insul.
O HP
Plenum Outside Buried
❑
I M lig I
XA
11-
,-4-
n
❑
`%.
V`
❑
I F�(� r;�w
t
a
EnergyPro 5.1 9-Y EnergySoft User Number: 6712
RunCode: 2013-05-10709:44:00 ID:
a of 29
UH 1 C �---
0
C
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Duffield Residence
Date
5/10/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
.*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
_.§1 10-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
4150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
-recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(i)3A: Insulation is protected from damage, including that due to sunlight, moi tur a 'merit -maintenance �arid wind
§1506)3A: Insulation for chilled water piping and refrigerant suction lines includes h v pbr retardant or, iis,encloseVk?nM '�,
► Itl (`Ij.-' i 6..3A
conditioned space. 1 pt! �
1 50 ' 4: Solar water-heatingsystems and/or collectors are certified b the Solar Ratingand Certif catjon, o Q M
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09*00 ID: Page_1 I of 29
UH 1 C �—
•
n
� J
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Duffield Residence
1511012013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
6150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
•§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
,and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
..programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
-.§1 50 k 7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
GF LA QUINTA
N G & SAFETY DEPT.
FI
OVER
EneryyPro5.ibyEnergySoft User Number. 6712 RunCode:2013-05-10709:44:00? FlD;oi' STRUC I 10 Wage12o 29
DATE BY
r_'9
LJ
C-1
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Duffield Residence
5/10/2013
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
.than 1000 square feet located on a residential site is not required to comply with 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
-dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or.bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
=more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
:requirements of Sections 130, 131, 134, and 146.
.§150(k)M Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
..dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
EnergyPro 51 by EnergySoR User Number., 6712 RunCode: 2013-05-10T09:44:00 ID: 13 of 29
•
C,
-HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Duffield Residence
Date
5/10/2013
System Name
HVAC 1
Floor Area
1,287
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 692
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem
71,000
13,646
2,045 372
16,152
Total Output Btuh
71,000
o
Output Btuh/s ft
55.2
788
794
Cooling System
01
0
Output perSystem
47,000
0
0 0
0
Total Output Btuh
47,000
0
788
1 15,221 2,045
0
Total Output ons
3.9
794
Total Output Btuh/s ft
36.5
Total Output s ft/Ton
328.6
1 17,740
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ANB748/58CVX090 33,122 4,517
71,000
Airflow cfm/s ft
1.24
Airflow cfm/Ton
408.5
Outside Air %
0.0%
Total Adjusted System Output 1 33,122 4,517
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
1
71,000
Outside Air cfm/s ft 0.00
-Note: values above given at ARI conditions
Jan 1 AM
-HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
72 OF
72 OF 113 OF 113 OF
Heating Coil Supply Fan
1,600 cfm 113 ° F
["ROOM
72 OF
,_COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
70!58°F
70/58°F 51/50°F 51/50°F
Cooling Coil Supply Fan °F
1,600 cfm. .....................
CITY- .2 IIA "
r_py
�! ilk.'®IN`a `yY ���q - 70 / 54 OF
CONSTRUCTION
EnergyPro 5.1 by EnergySoft
User Number: 6712 RunCode: 2013-05-10T09:44:60 /D: o __Pagek4 of 29
C
•
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Duffield Residence
Date
5/10/2013
System Name
HVAC 2
Floor Area
1,167
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK COIL HTG.
CFM Sensible Latent CFM
Total Room Loads 1,242 21,135 1,891 395
Return Vented Lighting 0
Return Air Ducts 1,220
Return Fan 0
Ventilationo 0 0 0
Supply Fan 2,978
Supply Air Ducts 1,220
TOTAL SYSTEM LOAD 1 26,553 1,891
PEAK
Heating System
Sensible
Output perSystem
89,000
17,824
Total Output Btuh
89,000
Output Btuh/s tt
76.3
876
-Cooling System
0
Output perSystem
57,500
0
Total Output Btuh
57,500
-2,978
Total Output ons
4.8
876
Total Output Btuh/s ft
49.3
Total Output s ftfron
243.5
16,598
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ANB760/ 58CVX110 39,451 6,912
89,000
Airflow cfm/s ft
1.71
Airflow cfm/Ton
417.4
Outside Air°/,
0.0%
Total Adjusted System Output 39,451 6,912 89,000
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM
Outside Air cfm/sqft
0.00
' Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
- 72 of
72 OF 113 OF 115 °F
Heating Coil Supply Fan
2,000 cfm 114 F
ROOM
72 OF
1
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
71 /59°F
71 /59°F 52/51 OF 53/52°F
Cooling Coil Supply Fan 5 of
/ /� ..............`...
CITY f 050 7 �oA t�I�
2,000 cfm FBU
DING & SFS �TY E
70/5 °F
F01-1 CONSTRUCTION
EnergyPro 5.1 by EnergySoR
User Number: 6712 RunCode: 2013-05-10709:44.;00 ID: \/ Pg415 of 29
•
C�
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Duffield Residence
Date
5/10/2013
System Name
HVAC 3
Floor Area
1,526
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK COIL HTG.
CFM Sensible Latent CFM
Total Room Loads 1,234 20,975 1,950 562
Return Vented Lighting 0
Return Air Ducts 1,211
Return Fan 0
Ventilation F 0 0 0 0
Supply Fan 2,978
Supply Air Ducts 1,211
TOTAL SYSTEM LOAD 26,37a 1,950
PEAK
Heatin_q System
Sensible
OutRut perSystem
89,000
25,152
Total Output Btuh
89,000
Output Btuh/s ft
58.3
1,236
System
0
-Cooling
Output perSystem
57,500
0
Total Output Btuh
57,500
-2,978
Total Output ons
4.8
1,236
Total Output Stuh/s ft
37.7
Total Output s ft/Ton
318.5
24,646
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ANB760/ 58CVX110 39,403 6,973
89,000
89,000
Jan 1 AM
Airflow cfm/s ft 1.31
Airflow cfm/Ton 417.4
Outside Air % 0.0%
Total Adjusted System Output 39,4031 6,9731
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
10
Outside Air
0 cfm
71 OF
71 OF 113 OF 115 OF
t
Heating Coil Supply Fan
1140F
2,000 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
.4
71 /59°F 52/51 OF 53/52°F
Cooling Coil Supply Fan 54 / 52 OF
2,000 cfm
?�50.1,8oA 18,QQTCITY
,71159°F t BUI( ��c8x S,"iFET t 70/ 9°F
4s v (r
t uR CONSTRUCTION
EnergyPro 5.1 by EnergySoR
User Number.' 6712 RunCode: 2013-05-10T09:44:00 /D: Pae 16 of 29
w
C,
J
•
•
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Duffield Residence
5/10/2013
System Name
Floor Area
HVAC 4
657
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 415
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD 1
COOLING
PEAK COIL HTG.
PEAK
.Heating System
Sensible
Latent CFM
Sensible
Output perSystem
71,000
8,216
1,040 219
12,746
Total Output Stuh
71,000
0
Output Btuh/s ft
108.1
474
626
Cooling System
0
0
Output perSystem
35,000
0
0 0
0
Total Output Btuh
35,000
0
1,040
0
Total Output ons
2.9
474
626
Total Output Btuh/s ft
53.3
Total Output s ft/Ton
225.3
9,165
1 13,999
Air System
" CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Alrflow (cfm)
1,200
Carrier 24ANB736/58CVX090 24,699 3,255
71,000
Airflow cfm/s ft
1.83
Total Adjusted System Output 1 24,699 3,255 1 71,000
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3P MI F Jan 1 AM
Alrflow cfm/Ton 411.4
Outside Air % 0.0%
Outside Air cfm/ ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
72 OF 127 OF 127 OF
Outside Air
^
0 elm
Heating Coil Supply Fan
127 °F
1,200 cfm
-"'In
.ROOM
72 OF
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
70/58°F 51 /50°F 51150°F
Outside Air Ar
0 cfm
Cooling Coil Supply Fan 51 / 50 OF
1,200 cfm.....................................................
48fi7'°,o oo T
C1 CJi r�
70/58°FBUIL�,�
1r`r 8, SAFETY D 0/68 F
# FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft
User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page 7 of 29
DATE _ — BY
•
0
ROOM LOAD SUMMARY
-
- . Residence
..
i
Name
HVAC 1
-FloorSystem
1,287
ROOM LOAD SUMWRY
eek
r�nM-�PAM M
•
•
ROOM LOAD SUMMARY
Project
-
'Duffield '- .511012013
Date
System Name
HVAC
..
1,167
ROOM LOAD SUMMARY
■■_ W_ ,
1�
Total includes ventilation loa.
PAGE • .1,„242, �•-;,21;;1,35= 1
TOTAL ,?1,242 ,� 2 �351 z .. -
395 17,824
395 17,824
•
0
ROOM L•SUMMARY
ProjectDate
Duffield Residence
i
Nam6
HVAC 3
FloorSystem
1, 526
ROOM LOAD SUMMARY
-Living Greatroom
PAGE TOTAI�7A
N WI
I®
•
•
C,
ROOM LOAD SUMMARY
Project Name
Duffield Residence
�• 219
12, 746
Date
5/10/2013
System Name
HVAC 4
Floor Area
657
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM Sensible Latent CFM Sensible
Casita Casita
1 415 8,216 1,040
415 8,216 1,040 219 12,746
A ot
' Total includes ventilation load for zonal systems.
PAGE TOTAL
TOTAL'
i11 t9•R �.� ''-1..iii i 1 1
415
�
219 12,746
414, 9716", -)
f vt i I�VIVS I tf I I
Ene Pro 5.1 b Ene Soft User Number: 6712
RunCode: 2013-05-10T09:44i00
ID: Pae 1 of 29
DATE BY
0
� , 04
�• 219
12, 746
•
0
•
ROOM HEATING PEAK LOADS
Project Name
Duffield Residence
Date
5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Bedroom
Floor Area 1,287.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
1,285.6 X
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
�e-2,/
AT OF Btu/hr
46 = 1,538
46 = 19
46 = 3,377
46 = 4,422
46 = 3,459
=
=
=
=
=
=
=
=
=
Page Total 12,815
G,p' X t p �6w3,337Schedule
sd7�
& SAFETY DEP .
...r
R-38 Roof(R.38.2x 14.16)
0.0260
Solatube Skylight
1.4
X
0.3000
R-21 Wall (W.19.2x6.16)
1,064.0
X
X
X
X
X
X
X
X
X
0.0690
Architectural Windows
209.0
0.4600
Slab -On -Grade
perim = 103.0
0.7300
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to
X 1,287 X
Area Ceiling
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Air Sensible
Fraction
another room
11.60.
Height (`®
v
BUIL�?1?,S
TOTAL HOURLY HEAT LOSS FOR ROOM 1,,152
FtJi CC)NSTRUU1I
Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page 22 of 29
•
0
0
ROOM HEATING PEAK LOADS
Project Name
Duffield Residence
Date
5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Gallery Entry Office
Floor Area 1,167.0 f 2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction Area U -Value AT *F
R-38 Roof(R. 38.2x 14.16) 1,165.6 X 0.0260 X 46
Solatube Skylight 1.4 X 0.3000 X 46
R-21 Wall (W.19.2x6.16) 1,030.7 X 0.0690 X 46
Wood Door 24.0 X 0.5000 X 46
Architectural Windows 277.3 X 0.4600 X 46
Slab -On -Grade perim = 110.0 X 0.7300 X 46
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
Items shown with an asterisk (") denote conduction through an interior surface to another room Page Total
Infiltration:[ 1.00 X 1.064 X 1,167 X 1160-X' 0`,0 :1, I
Schedule Air Sensible Area Ceiling Height C A6, ( eT
Fraction
BUILDING, &SAI=ETY
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
1,394
19
3,271
552
5,868
3,694
14,798
4e6 - 3,026
' `" J
DEPT.
TOTAL HOURLY HEAT LOSS FOR ROOMJ V Lm 17,824
i ,=J=�c0,,4S-VHUU I ION I
Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page E3 of 29
C]
•
ROOM HEATING PEAK LOADS
Project Name
Duffield Residence
Date
5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living Greatroom
Floor Area 1,526.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U -Value AT OF Btu/hr
1,526.0 X 0.0260 X 46 c 1,825
1,289.9 X 0.0690 X 46 = 4,094
445.1 X 0.4600 X 46 _ 9,418
24.0 X 0.5000. X 46 c 552
perim = 158.0 X 0.7300 X 46 = 5,306
X X =
X X
X X =
X X
X X =
X X =
X X
X X
X X
X X =
X X =
X X
X X
X X =
X X
X X =
X X
X X =
X X =
X X =
X X =
X X
X X
X X
X X =
X X
through an interior surface to another room Page Total 21,195
X 1,526 X 12.60,-X, 3,957
Area Ceiling Height QH "'dT`
BUILOI' & J�FETY DEPT.
�.- icn
R-38 Roof(R.38.2x 14.16)
R-21 Wall (W.19.2x6.16)
Architectural Windows
Wood Door
Slab -On -Grade
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
'
x" t�� °'— 2 152
►-�Ji-t ��;v5r Ad
Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-10709:44:00
ID: Page 24 f 29
•
•
ROOM HEATING PEAK LOADS
Project Name
Duffield Residence
Date
5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 657.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction Area
R-38 Roof(R. 38.2x 14.16) 657.0
R-21 Wall (W.19.2x6.16) 1,146.1
Architectural Windows 131.9
Slab -On -Grade perm = 114.0
Items shown with an asterisk (') denote conduction through an interior surface
Infiltration:[ 1.00 X 1.064 X 657 X
Schedule Air Sensible Area
Fraction
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
AT OF
46 =
Btu/hr
0.0260
X
786
0.0690
X
46
=
=
=
3,638
0.4600
X
X
46
2,791
0.7300
46
3,828
X
X
=
=
=
X
X
=
X
=
X
X
=
=
X
X
X
=
=
=
X
X
X
X
X
X
=
=
=
=
=
=
=
=
=
X
X
X
X
=
X
=
X
=
X
=
=
=
X
X
X
=
X
another room
11.00 X 0.289
Height ACS;
=
Page Total
�% 60 ]'�X ,
DING &
APPROVED
11,043
1, 04
TOTAL HOURLY HEAT LOSS FOR ROOM ; F0 1 �Ui`�j i RUG 1 10N 12,7 6
i
t
Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 I-jAID<-----57,-579
0
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Duffield Residence
1 5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master Bedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1, 287.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x 14.16)
(N) 1,285.6 X 0.0260 X 56.0 =
1,872
R-21 Wall (W. 19.2x6.16)
(N) 130.0 X 0.0690 X 23.0 =
206
R-21 Wall (W. 19.2x6.16)
(SE) 665.0 X 0.0690 X 31.0 =
1,422
R-21 Wall (W. 19.2x6.16)
(S) 189.0 X 0.0690 X 26.0 =
339
R-21 Wall (W. 19.2x6.16)
(VV) 80.01 X 0.0690 X 33.0 =
182
X X =
X X =
X X =
X X =
Page Total
4,022
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
Skylight
(N) 0.0 X 17.5 + 1.4 X 58.1 =
81
Window
(N) 0.0 X 23.7 + 100.0 X 23.7 =
2,367
Window
(SE) 0.0 X 23.7 + 5.0 X 32.6 =
196
Window
(SE) 0.0 X 23.7 + 49.0 X 32.6 =
1,600
Window
(SE) 0.0 X 23.7 + 9.0 X 32.6 =
294
Window
(SE) 0.0 X 23.7 + 30.0 X 32.6 =
979
Window
0.0 X 23.7 + 15.0 X 46.8 =
702
X + X -
X + X -
Page Total
6,220
Internal Gain
Btu/hr
Occupants
2.0 Occupants X 230 Btuh/occ.=
460
Equipment
0.0 Dwelling Unit X 1,600 Btu =
0
Infiltration: 1.064
X 0.94 X 70.43 X 42 =
2,944
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,646
Latent Gain
Btu/hr
Occupants
2.0 Occupants X r-.--200-Btuh/nc
410
CITY OF LA QU
Infiltration: x,771
X 0.94 X 70.43 x 0.00523 = BUILDING & SAFETYDEPTiA
Air Sensible
CFM ELA DW I v PROVED
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM F�.z-: �.Iv I ���' I
2,045
EnemvPro 5.1 by EnemySoft
User Number: 6712 RunCode: 2013-05-10709:44:00 P ID: Page 26 of 2
ur•, i I- -__----- - • -�
-
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project NameDate
Duffield Residence
5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Gallery Entry Office
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,167.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(N) 1,165.6 X 0.0260 X 56.0 =
1,697
R-21 Wall (W. 19.2x6.16)
(SE) 306.0 X 0.0690 X 31.0 =
655
Wood Door
(SE) 24.0 X 0.5000 X 31.0 =
372
R-21 Wall (W. 19.2x6.16)
(S) 361.7 X 0.0690 X 26.0 =
649
R-21 Wall (W. 19.2x6.16)
(KO 363.0 X 0.0690 X 33.0 =
827
X X =
X X =
X X =
:J X X =
Page Total
4,199
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
t. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
Skylight
(N) 0.0 X 17.5 + 1.4 X 58.1 =
81
Window
(S) 0.0 X 23.7 + 5.3 X 23.8 =
126
Window
(S) 0.0 X 23.7 + 32.0 X 23.8 =
760
Window
W 0.0 X 23.7 + 80.0 X 46.8 =
3,746
Window
(W) 0.0 X 23.7 + 80.0 X 46.8 =
3,746
Window
(W) 0.0 X 23.7 + 80.0 X 46.8 =
3,746
X + X -
X + X -
X +1 X -
Page Total
12,206
Internal Gain
Btu/hr
Occupants
2.0 Occupants X 230 Btuh/occ. =
460
Equipment
1.0 Dwelling Unit X 1,600 Btu =
1,600
Infiltration: 1.064
X 0.94 X 63.86 X 42 =
2,669
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
21,135
Latent Gain
Btu/hr
Occupants
2.0 Occupants X 200 Btuhh//occ.
400
Infiltration: 4,771
D
p=
D D CITY a"fF L.V�
X 0.94 X 63.86 X 0.00523 _ MEZ
491
Air Sensible
CFM ELA AW �(-ii�_�'� 1'z •SAFETY
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ;, aT - I
1. .91
Ene Pro 5.1 6 Ene Soft
User Number.- 6712 RunCode: 2013-05-10709:44:00 ID: Pa a 27 0 29
IDATE BY I
.7
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Duffield Residence
1 5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living Greatroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,526.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x 14.16)
(N) 1,526.0 X 0.0260 X
56.0 =
2,222
R-21 Wall (W. 19.2x6.16)
(N) 372.0 X 0.0690 X
23.0 =
590
R-21 Wall (W. 19.2x6.16)
(SE) 68.0 X 0.0690 X
31.0 =
145
Wood Door
(SE) 24.0 X 0.5000 X
31.0 =
372
R-21 Wall (W.19.2x6.16)
(S) 362.9 X 0.0690 X
26.0 =
651
R-21 Wall (W.19.2x6.16)
(tM 487.0 X 0.0690 X
33.0 =
1,109
X X
=
X X
=
X X I=
Page Total
5,oso
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Window
(N) 0.0 X 23.7 + 120.0
X 23.7 =
2,841
Window
(N) 0.0 X 23.7 + 180.0
X 23.7 =
4,261
Window
(S) 0.0 X 23.7 + 65.1
X 23.8 =
1,547
Window
(lM 0.0 X 23.7 + 80.0
X 46.8 =
3,746
X +
X -
X +
X -
X +
X =
X +
X -
X +1
X -
Page Total
12,395
Internal Gain
Btu/hr
Occupants
0.0 Occupants X 23o Btuh/occ. =
o
Equipment
0.0 Dwelling Unit X 1,600 Btu
=
0
Infiltration: 1.064
X 0.94 X 83.50 X 42 =
3,490
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
20,975
Latent Gain
Btu/hr
Occupants
O.o Occupants X 200 -Bta-h/mop
. t- /�=ZQ)7�7
oCr
Infiltration: 4,771
i ti
X 0.94 X 83.50 X 0.00523 = �� ",s�'
0f_ E..,A
:�; OAFEIFY
DERT0
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM r .:
► �� t r5
950
EnerovPro 5.1 by EnemySoft
User Number: 6712 Run Code: 2013-05-10709:44:00 PID:
Pa
a 28 of 29
•
0
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project NameDate
Duffield Residence
5/10/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area
657.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R. 38.2x 14.16)
(N) 657.0 X 0.0260
X
56.0 =
957
R-21 Wall (W. 19.2x6.16)
(N) 178.0 X 0.0690
X
23.0 =
282
R-21 Wall (1..19.2x6.16)
(SE) 373.4 X 0.0690
X
31.0 =
799
R-21 Wall (W. 19.2x6.16)
(S) 213.7 X 0.0690
X
26.0 =
383
R-21 Wall (W. 19.2x6.16)
(1M 381.0 X 0.0690
X
33.0 =
868
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
3,289
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Window
(N) 0.0 X 23.7 +
80.0
X 23.7 =
1,894
Window
(SE) 0.0 X 23.7 +
3.8
X 32.6 =
124
Window
(SE) 0.0 X 23.7 +
3.8
X 32.6 =
124
Window
(S) 0.0 X 23.7 +
5.3
X 23.8 =
126
Window
(S) 0.0 X 23.7 +
39.0
X 23.8 =
927
X +
X -
X +
X -
X +
X -
X +
X -
Page Total 1
3,195
Internal Gain
Btu/hr
Occupants
1.0 Occupants X 230
Btuh/occ.
=
230
Equipment
0.0 Dwelling Unit X 1,600
Btu
=
0
Infiltration: 1.064
X 0.94 X 35.95 X 42 =
1,503
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
8,216
Latent Gain
Btu/hr
Occupants
1.0 Occupants X 200
Btuh/occ.
=
200
Infiltration: 4,771
X 0.94 X 35.95 X 0.00523 -�
7--,f
Air Sensible
CFM ELA AW
& SAFE
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
EnemvPro 5.1 by Ene SoR
User Number: 6712 RunCode: 2013-05-10709:44:00 1a
Page
29 of 29
`E3gctronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
'Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Duffield Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/10/2013
Project Address
78-331 Deacon Drive Lot 14 La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,637
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If YeS,•A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 4,634 Radiant Barrier New
Wall Wood Framed
R-21 4,531 New
Slab Unheated Slab -on -Grade
. None 4,637 Perim = 485' New
Door Opaque Door
None 48 New
FENESTRATION; ' iU- Exterior
Orientation...._.Area ctor SHGC Overhang Sidefins Shades Status
Skylight 1.4 7- 0.300
0.30 none none None New
l:
Rear(N) : _ .:.. 480.0 0 460 , „ ' 0 39none none .. - - Bug Screen New
Right (SEj , : 101.6 0 4600
A
39 none noneyBug Screen New
�r
Left (MX335`0 , 060
0 39�nohe }' ` .none Bug Screen,„ 4 New -.: ,..
Skylrght `; w1
New;; .
Front,(Aj f746 7� 39none r'?`�norie � Bug�Screen�f
ti_ d.. j
ti
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback New
1 Central Furnace 80% AFUE
Split Air Conditioner 15.0 SEER Setback New
1 Central Furnace 80% AFUE
Split Air Conditioner 15.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location -V e t tus
HVAC 1 Ducted
Ducted Attic, Ceili In�g18.
e
HVAC 2 Ducted
Ducted Attic, Ceilint9Ins vented�t�t(� & SAW 'N'eKA
HVAC 3 Ducted
Ducted Attic, Ceiling Ins; ventedNew
�ga
�$ CTI WATER HEATING inCOMgTR
Ot . Type Gallons Min. Eff Distribution StJos
1 Large Gas 100
0.99 All Pipes Ins R �New—
Ene Pro 5.1 bAEhSg^ nNer Number: 6 12
RunCode: 2013-05-10709:44:00 ID:
Pae 1 H8
Reg: 213-N0028242C-000000000-0000' Regi*ration Date/ Time: 2013/05/10 11:10:06
CI "Y Z' L:� (�UINTA
C0^ N DEVELOPMENT �
HERS Provider: CalCERTS, inc
3
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R
Project Name Building Type m Single Family ❑ Addition Alone Date
Duffield Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/10/2013
p3 Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Stories
78-331 Deacon Drive Lot 14 La Quinta CA Climate Zone 15 4,637 n/a 1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
k Construction Type Cavity ( Features see Part 2 of 5 Status
R
FENESTRATION:;:'`' U- Exterior
.:.
Orientat on.........,,Area F
� actor SHGC Overhang Sidefins Shades Status
4",
t
IN
ARM. M
hX»..� .. ..
�.,x..'.
..............
... ..... ..... ......... ......
r
_ r -.
:j.r r•-5 ''E
_. .
3':: Ef :I
............
r
HVAC SYSTEMS --
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 17.7 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Ot . Type Gallons Min. Eff Di rie-A tbeA oF LA QUINTAa us
� Ty t
r,►t�it; SA '
' vn
Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-05-10T09:4 .:00 ID: Pa 2 of 8
'Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013/OS/101t11�1T00 P nc
Riectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
Electronically Signed at CalCERTS.com by Jody. Jones (Jody Jones Development Corporation) 5/14/2013
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Building Type ® Single Family ❑ Addition Alone
Date
Duffield Residence
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
1511012013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Bradford -White #MN-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 667.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom
HIGH MASS Design - Verify Thermal Mass: 620.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom
The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 341.0 ft2 Covered Slab Floor, 3.500" thick at Gallery Entry Office
HIGH MASS Design - Verify Thermal Mass: 826.0 ft2 Exposed Slab Floor, 3.500" thick at Gallery Entry Office
The HVAC System. HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air; flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify TheiinalfMass: 436.0 ft2 Covered Slab Floor, 3.500" thick at Living Greatroom
HIGH MASS Design - Verify Thermal'Mass: 1,090.0 ft2 Exposed Slab Floor, 3.500" thick at Living Greatroom
... .............
_
The HVAC System HVAC 4 must semi only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the airifiow, re. uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
H/GHMASS ilesignVenfy Thermal:.Mass 275 0£ft2 GoveredSlab?Floor 3 500 thicket Casrt
€;7..
HIGH IWASS Design - Verify Thermal'Mass 382`0`ft2 Exposed Slab Floor 3.500 'thick at1Gasita ° ra
3 -
HERSFREQ;UIRD�IERIFICTIU
Items n;thls secbon5requlre field testing andlor venflcat)on by a certified'HERS Mater! :., The InSpector.musVrecelve a
-rte
R form for eacf of the.measUres:hsted below for final at even:
cofnleted GF 4' ' 'f` l' ac '
The Cooling System":Carrier 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation
of.:.the,correct_Condenser
The HVAGSystem HVAC 1;incorpoil tes HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incgrpoiatds HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria;;
The Cooling System Carrier 24ANB760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB760158CVXI 10 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB736158CVX090 includes credit for a 13.7 EER Condenser. A certified HERS rater mus the installation
of the correct Condenser.
The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a @hargQ a l�dicator pis�lay
y
l� g DEP
- c T -
The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field v t cgignn 1,6', iagriostic tdst�ingd is.requ ed to ven that duct
leakage meets the specified criteria. �r n `�
����� 1 UC
FOR
Erie Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-05-10 09:44:0x0 D: Pa e 3 of 8
Reg: 213 -000000000-0000 Registration Date/Time: 2013/ 0;5�1�OTfl-.10:0 i� ERTS, Inc
.. Fa
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
Electronically Signed at Ca10ERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013
. I '
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Duffield Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/10/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
'determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Bamfer that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
Ud
.:
r 47
:.:�.: .� 'K.'I�i;.se�4'F.;
xSl-
' `p, j f t ....
HERSREQYUIR�EDy VERIFICATION �'� �t'3%��
k`sN.. A+ ' .^yW4 >�3!! C'F"' i C. • i '-#YA }tti:R..
Items In this section reGu(re f eld,iest)ng and/or �enftcatlon by a certrfled'NERS Rater PrThe Inspector.,musvrece)ve a
com Ie�ted.QF 4'R form for eacFiCof,:.the:-meas.tres:aisted=below for f)rial to be even°:
...............:..._....... ...._._...._............
H
iiia
SAFETY DEPT.
DROVE®
FOR CONST I
EneMyPro 5.1 bv EneMySoft User Number: 6712 RunCode: 2013-05 OT09:44:00 I Page 4 of 8
I DATE
Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013./-"4 1 1'f): S Provider: Ca10ERTS, Inc
.Ele.ctronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013
{ � w
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Duffield Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
5/10/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 4.50 4.27 0.23
Space Cooling 59.84 53.10 6.74
Fans 11.96 16.26 -4.30
Domestic Hot Water 7.87 4.27 3.59
Pumps 0.00 0.00 0.00
Totals 84.17 77.90 6.27
Percent Better Than Standard: 7.4%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S)180deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 1,274 147
Fuel Available at Site: Natural Gas (K9 1,646 335
Raised Floor Area: 0 (N) 1,160 480
Slab on Grade Area: 4,637 (E) 1,562 102
Average Ceiling Height:._;. R. 11.8 Roof 4,637 3
Fenestration Average U -Factor: 0.46 TOTAL: 1,066
Avera a SHG;' G` 0.39 Fenestration/CFA Ratio: 23.0%
REMARKS`°`-�'
Traditions Country Club Lot 14 T
fme.,
1:- ...ss:M ..... �...
STATEMENT OF COMPLIANCE ;.
,
This certificate comp lance lists;the building features and specifications needed
to comply with Title P`arts:l.Administrative Regulations and Part 6 the
Efficiency Standards of thCalfornia Code of Regulations.
The documentation author her certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
5/10/2013
Address 77-085 Michigan Drive Name Tim Scott
Ci /State2i Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and'recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) CITY OF LA QUANTA
Company Design Mind Studios DEPT.
����
Address 74 -79442nd Ave, Suite 9 Name Gordon Stein BUILDING &
City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-4488 AE Signed � V C-Niic� e # Date
FOR cutis
Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-10T0 :44:00 1141Page 5 of 8
vim,
Reg: 21 5,1
'3-N0028242C-000,000000-0000 Registration Date/Time: 2013/010 11:10:0 HERS. RTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Duffield Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1511012013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,286
0.026 R-38
0 20 New 4.2.1-A9
Master Bedroom
Wall
130
0.069 R-21
0 90 New 4.3.1-A6
Master Bedroom
Wall
665
0.069 R-21
135 90 New 4.3.1-A6
Master Bedroom
Wall
189
0.069 R-21
180 90 New 4.3.1-A6
Master Bedroom
Wall
80
0.069 1 R-21
270 90 New 4.3.1-A6
Master Bedroom
Slab
667
0.730 None
0 180 New 4.4.7-A1
Master Bedroom
Slab
620
0.730 None
0 180 New 4.4.7-A1
Master Bedroom
Roof
1,166
0.026 R-38
0 20 New 4.2.1-A9
Gallery Entry Office
Wall
306
0.069 R-21
135 96 New 4.3.1-A6
Gallery Entry Office
Door
1 24
0.500 None
135 90 New 4.5.1-A4
Gallery Entry Office
Wall
362
0.069 R-21
180 90 New 4.3.1-A6
Gallery Entry Office
Wall
363
0.069 R-21
270 90 New 4.3.1-A6
Gallery Entry Office
Slab
341
0.730 None
0 180 New 4.4.7-A1
Gallery Entry Office
Slab
826
0.730 None
0 180 New 4.4.7-A1
Gallery Entry Office
Roof
1,526
0.026 R-38
0 20 New 4.2.1-A9!Living
Greatroom
Wall
372
0.069 R-21
1 01 90 1 New 14.3.1-A6
ILiving Greatroom
FENESTRATION SURFACE DETAILS
ID
Type.
Area LI -Factor' SHGC
Azm Status Glazing Type
Location/Comments
1
Skylight
1.4. 0.300 NFRC 0.30 NFRC
0 New Solatube Skylight
Master Bedroom
-2_,:
Window
100.0 0.460 NFRC 0.39 NFRC
0 New Architectural Windows
Master Bedroom
3
Window " = 6.0 0.460 NFRC 0.39 NFRC
135 New Architectural Windows
Master Bedroom
4,.
Window
49.0 0.460 NFRC 0.39 NFRC
135 New Architectural Windows
Master Bedroom
5 ' : Window,,..
_ r9.0 0.460 NFRC ,;0:39. NFRC _ 135 New _. _, „ ,Arohitectural_l Windows ,. ,..�_, Master Bedroom
6 _
. Window-
"x-30:0 0.460 'NFRC,•f :. '0.39' NFRCkss„
` _ ,__'135 New; r � 'ti Architectural Windows; �
g 'Master Bedroom
7
Wndow =
� 15.0 0,460 ,NFRC,,Y 0:39 'NFRC,7'
',270 ,NeW' _ Architectural, Windows.,
Master, Bedroom
8
Skylight,
t1_ 1,0.30Q; NFRC` 0.30 NFRC "M'•
0 New_,-: � o.1atu6ejSkylight: _
Ga11ery Entry Office, -
9
Window
,5.3 x':0:460 NFRC'' 0.39 NFRC
'. 180 ,New : -' 'Architectural Windows N
Gallery;Eptry Office .
10
Wndow
,f32.0; ,,ir;„0.460. NFRC.;; - 0.39`-'NFRC,,
Architectural Windows }
Gallery '_Entry' ;Office
11 ,:
Wndow 1
%, 80.0 ;,'°0:460 NFRC`: X0'39: "NFRC;-.1180
New ArchitecturaLWindows ---�
. Gallery Entry+Office
12:;
Window , :;
. .80:0 , 0.460 NFRC 0.39 NFRC
New. Architectural -Windows
` 'Gallery Entry Office
13
Window W 80.0 0.460 NFRC `' 0.39 NFRC
New Architectural Windows
GalleryEnt Office
,'`14. window
120.0 0.460 NFRC 0.39 NFRC
New Architectural Windows
Living Greatroom
15
Window
180.0, 0.460 'NFRC 0.39 NFRC
New Architectural Windows
Living Greatroom
16"
Window
65:'1; ',._.0.460, NFRC 0.39 NFRC
New Architectural Windows
Living Greatroom
(1) LI -Factor Type: , :;,,,,11,6-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: ".1'16 B efault Table from Standards, NFRC =Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
Hat Dist Len H t
1
None
1.00
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
None
1.00
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.761
QTV
16
IBug Screen
0.761 1
l i I I ski pt •.)!-31 L-; I I
2F)P,0VED
EnergyPro
5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10;f09:44: 0r -sr -3 r-1D•t "
Pa e 6 of 8
Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013/05/10 11:10: 6 RS o ider: Ca10ER S, inc
DATE
Electronically Filed by Tim Scott and Authenticated
Electronically Signed at CalCERTS.com by Jody Jones
at CalCERTS.com - 5/14/2013
(Jody Jones Development Corporation) 5/14/2013
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Duffield Residence
Building Type m Single Family 13 Addition Alone
O Multi Family O Existing+ Addition/Alteration
Date
1511012013
OPAQUE SURFACE DETAILS
Surface Ll- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall 68 0.069 R-21 135 90 New 4.3.1-A6 Living Greatroom
Door 24 0.500 None 135 90 New 4.5.1-A4 Living Greatroom
Wall 363 0.069 R-21 180 90 New 4.3.1-A6 Living Greatroom
Wall 487 0.069 R-21 270 90 New 4.3.1 A6 Living Greatroom
Slab 436 0.730 None 0 180 New 4.4.7-A1 Living Greatroom
Slab 1,090 0.730 None 0 180 New 4.4.7-A1 Living Greatroom
Roof 657 0.026 R-38 0 20 New 4.2.1-A9 Casita
Wall 178 0.069 R-21 0 90 New 4.3.1-A6 Casita
Wall 373 0.069 R-21 135 90 New 4.3.1-A6 Casita
Wall 214 0.069 R-21 180 90 New 4.3.1-A6 Casita
Wall 381 0.069 R-21 270 90 New 4.3.1-A6 Casita
Slab 275 0.730 None 0 180 New 4.4.7-A1 Casita
Slab 382 0.730 None 0 180 New 4.4.7-A1 Casita
FENESTRATION SURFACE:DETAILS
ID Type Area lJ-Factor SHGC Azm Status Glazing Type Location/Comments
17 Window 80.0. 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Living Greatroom
18_,: Window 86.0 0.460 INFRC 0.39 NFRC 0 New Architectural Windows Casita
..119 Window"'` 3.8 0.460 "NFRC 0.39 NFRC 135 New Architectural Windows Casita
20. Window 3.8. 0.460 NFRC, 0.39 NFRC 135 New Architectural Windows Casita
21:y Window-� - _... „ 5.3 0.460 NFRC w5 _0 39: NERC 1.8,0. New....,Architectural..Windo_w,s ..�.,,:._ Casita
22 ; Window' - X39 0 0.4607 ,0 39' ;NFRC.x*v , 1,80:'New ;.' Architecturel-Wndows ?';.F Cesita
-.
Z�
{ypss ,.s# rb . Y : �- _ ,. .4. k, £' � '+Y ...to•C°.G.. R,'i :M:.°'� f` _&-:'
VOW, 111; ks%h X .: ;: 172t--'_ Y k4, -Y d.' : .:. t ;9�. t 5/`: ...'...,.. ". ✓ i �' 1"�F r'E. ::
V AMM Z If
........_......:... . .........:.:::.::.:
(1) 1.1 -Factor Type: ikl6-A _ Default Table from Standards, NFRC = Labeled Value
2 SHGCT e: `.1i1.67B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hanq Left Fin Ri ht Fin
ID Exterior Shade Type SHGC Hat Wd Len H t LExt RExt Dist Len H t Dist Len I Hot
17 Bug Screen 0.76
18 Bug Screen 0.76
19 Bug Screen 0.76
20 Bug Screen 0.76
21 Bug Screen 0.76
22 Buq Screen 0.76
r L 9n
aG P CA
Q, �` JVED
Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2013-05-10 09:44:00:(—IRI '' H U Pa e 7 of 8
Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013/0 /10 11:1 RS ider: Ca10ERT , inc
DATE -
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013
Electronically Signed at Ca10ERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013
t, .0
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R
Project Name
Duffield Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1511012013
BUILDING ZONE INFORMATION
Floor Area ft
System Name Zone Name New Existinq Altered Removed Volume Year Built
HVAC 1 Master Bedroom 1,287 14,929
HVAC 2 Gallery Entry Office 1,167 13,537
HVAC 3 Living Greatroom 1,526 19,228
HVAC 4 Casita 657 7,227
Totals 1 4,6371 01 0 0
HVAC SYSTEMS
;;S stem Name,:";Qt : V. -Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 1 's Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New
HVAC 2 1 ICentral Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New
v
HVAC 3 _ _. 1 :. Central;Fumace`, , 760%?AFUE 'S li 'GondWoner, •; 15 0 SEER $etbaek ,.:. New
FIVAC"`4, , ' 1 ;; Centr`a1�F_umac e` 80% AFUE* S IIt1Alr%Ondi Joner 1,4 Z SEER. Setback;; New
;: =" ", f. '::'c: L hex. -'.3 �.. .:_ .. F 3 p: •W: Y'"f
. .. i ...: ..
VIA.:'..:i.: �"s - oX. ..T�¢�F,.•C.. '4 ..Ssi.Y-:ajy,'.. ii.e..i
HVAC DISTRIBUTION -z` . ,.: :t�srv', ....._ ._`.. :: ; ^.A,;W...``�r , .._.
=k1. F , , Duch Ducts?,
S stem Narne .r .. ea in :...:Cool�n ..._ ... _.. Duct.LocationE R.Value Tested? Status
HVAC 1;,gf, Ducted I_ Ducted Attic, Ceiling Ins, vented 8.0 m New
Ducted `' Ducted Attic, Ceiling Ins, vented 8.0 m New
HVAC3 `_ - Ducted i.,.. Ducted Attic, Ceiling Ins, vented 8.0 El New
Y _
HVAC 4 li % _Ducted0 Ducted Attic, Ceiling Ins, vented 1 8.01 ❑ New
❑
WATER HEATING SYSTEMSP:'
S stem Name
Qty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White #MN -1-100
1
Large Gas
All Pipes Ins
85,000
100
0.99
0.00 %
0.0
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
C
0
i�
v
a `-
Pipe
System Name Length
Pipe Insul.
Diameter Thick.
Q HP
Plenum Outside Buried
❑
1 °
I
e
1 C
4 BUILDINGSAF"11_1 ,
-9-1
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09:44:00 1" IDI) i .'� L.�, N ``: k," Tf e 8 of 8
)I CTION
Regi 213-N0028242C-000000000-0000 Registration Date/Time: 2013/05/1LD.6*