13-0380 (SFD) Title 24E • BUILDING ENERGY ANALYSIS REPORT PROJECT: Duffield Residence 78-331 Deacon Drive Lot 14 La Quinta, CA 92253 Project Designer: Design Mind Studios 74-794 42nd Ave, Suite 9 Palm Desert, Ca 92211 (760) 773-4488 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, • 77-085 Michigan Drive Palm Desert, CaF 1•.-A Qvi EpT, (760) 200-47 0C p1® & Sp'FET`( D RpR®vE®� F4R CpN S� I Date: MAY 15 2013 5/10/2013 CITY OF 1A QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: r== TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1R Mandatory Measures Summary 11 HVAC System Heating and Cooling Loads Summary 14 Room Load Summary 18 Room Heating Peak Loads 22 Room Cooling Peak Loads 26 • CITY 0-17 LA QUINTA E?11js_D& SAFETY DEPT. APPROVE® FOR CONSTRUCTIn^' EneravPro 5.1 by Energvsoft Job Number: ID: I BATE User NL"mbev-6712 • :7 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1511012013 Date Project Address 78-331 Deacon Drive Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,637 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ( Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,634 Radiant Barrier New Wall Wood Framed R-21 4,531 New Slab Unheated Slab -on -Grade None 4,637 Perim = 485' New Door Opaque Door None 48 New FENESTRATION Orientation Area U- Exterior Factor SHGC Overhang Sidefins Shades Status Skylight 1.4 0.300 0.30 none none None New Rear (N) 480.0 0.460 0.39 none none Bug Screen New Right (SE) 101.6 0.460 0.39 none none Bug Screen New Left (WJ 335.0 0.460 0.39 none none Bug Screen New Skylight 1.4 0.300 0.30 none none None New Front (S) 146.7 0.460 0.39 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented _._ �:0 New WATER HEATING Ot . Type Q� --L 4, UJIN Gallons Min. Eff FDstri';bt�tion s c; o =E -(Y DEPT. , tatus 1 Large Gas 100 0.99 1 Arl:Pipes Ins., , .. ; , ; P New liiTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013 -05 -10T09;44:09 ----ID=— Page 3 of 29 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1511012013 Date Project Address 78-331 Deacon Drive Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,637 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 17:7 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING , �; !!\ QUINTI A itatus Ot . T e Gallons Min. Eff Distribution , .. , -,-„ nl`P ■ N EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09:44:00.: ID: Pa e 4 of 29 • 0 L I PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Duffield Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/10/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White #MN-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 667.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 620.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 34 1. 0 ft' Covered Slab Floor, 3.500" thick at Gallery Entry Office HIGH MASS Design - Verify Thermal Mass: 826.0 ft2 Exposed Slab Floor, 3.500" thick at Gallery Entry Office The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the airflow requirements and fan waft draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass 436.0 ft2 Covered Slab Floor, 3.500" thick at Living Greatroom HIGH MASS Design - Verify Thermal Massa 1, 090.0 ft2 Exposed Slab Floor, 3.500" thick at Living Greatroom The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 275.0 ft2 Covered Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 382.0 ft2 Exposed Slab Floor, 3.500" thick at Casita HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB736156CVX090 includes credit for a 13.7 EER f3IE —rater must d veri the installation �Conden-sgr—A.certified of the correct Condenser. } r % IT! � �\ ��� The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge ora Charge Indicator t rispley. PU1'_�f The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnosticttesting is"regdired to vet that duct leakage meets the specified criteria. EnemyPro 5.1 by Enem YSoft User Number., 6712 RunCode: 2013-05-10709:44:00 ID: RY Page 5 of 29 UH1��� 0 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Duffield Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/10/2013 'SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. � T CITY CM- ! YY ... ir- Q. L F TY DEPT. FOR ID: Enem-Pro5.1 b Ene Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Pa e 6 of 29 IDATE ---- BY • • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Duffield Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 5/10/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2 r Space Heating 4.50 4.27 0.23 Space Cooling 59.84 53.10 6.74 Fans 11.96 16.26 -4.30 Domestic Hot Water 7.87 4.27 3.59 Pumps 0.00 0.00 0.00 Totals 84.17 77.90 6.27 Percent Better Than Standard: 7.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,274 147 Fuel Available at Site: Natural Gas (W 1,646 335 Raised Floor Area: 0 (N) 1,160 480 Slab on Grade Area: 4,637 (E) 1,562 102 Average Ceiling Height: 11.8 Roof 4,637 3 Fenestration Average U -Factor: 0.46 TOTAL: 1,066 Average SHGC: 0.39 Fenestration/CFA Ratio: 23.0 REMARKS Traditions Country Club lot 14 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and compiete. Documentation Author Company Scott Design and Title 24, Inc, 5/10/2013 JA� Address 77-085 Michigan Drive Name Tim Scott Citv/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) A UINTA Company Design Mind Studios i A"- �- D Address 74-794 42nd Ave, Suite 9 Name Gordon Stein ;-Jii_ r'ti`�g, �r " 114111 t City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-4488 AP�' ed -� n # ate F - RUC EnemvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: a e 7 of 29 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/10/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavit7yExterior Frame Interiorl Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,286 0.026 R-38 0 20 New 4.2.1-A9 Master Bedroom Wall 130 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 665 0.069 R-21 135 90 New 4.3.1-A6 Master Bedroom Wall 189 0.069 R-21 180 90 I New 4.3.1-A6 Master Bedroom Wall 80 0.069 R-21 270 90 New 14.3.1-A6 Master Bedroom Slab 667 0.730 None 0 180 New 4.4.7-A 1 Master Bedroom Slab 620 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,166 6.026 R-38 0 20 New 4.2.1-A9 22Ln Entry Office We 306 0.069 R-21 135 90 New 4.3.1-A6 Gallery Entry Office Door 24 0.500 None 135 90 New 4.5.1-A4 Gallery Entry Office Wall 362 0.069 R-21 180 90 New 4.3.1-A6 Gallery Entry Office Wall 363 0.069 R-21 270 90 New 4.3.1-A6 Gallery Entty Office Slab 341 0.730 None 0 180 New 4.4.7-A1 Galle Ent Office Slab 826 0.730 None 0 180 New 4.4.7-A1 GalleryEnt Office Roof 1,526 0.026 R-38 0 20 New 4.2.1-A9 Livin Greatroom Wall 372 0.069 R-21 0 90 New 4.3.1-A6 Livin Greatroom FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments- 1 Skylight 1.4 0.300 NFRC 0.30 NFRC 0 New Solatube Skylight Master Bedroom 2 Window 100.0 0.460 NFRC 0.39 NFRC 0 New Architectural Windows Master Bedroom 3 Window 6.0 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Master Bedroom 4 Window 49.0 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Master Bedroom 5 Window 9.0 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Master Bedroom 6 Window 30.0 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Master Bedroom 7 Window 15.0 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Master Bedroom 8 Skylight 1.4 0.300 NFRC 0.30 NFRC 0 New I Solatube Skylight Gallery Entry Office 9 Window 5.3 0.460 NFRC 0.39 NFRC 180 New Architectural Windows Gallery Entry Office 10 Window 32.0 0.460 NFRC 0.39 NFRC 180 New Architectural Windows Gallery Entry Office 11 Window 80.0 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Gallery Entry Office 12 Window 80.0 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Gallery Entry Office 13 Window 80.0 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Gallery Entry Office 14 Window 120.0 0.460 NFRC 0.39 NFRC 0 New Architectural Windows Living Greatroom 15 Window 180.0 0.460 NFRC 0.39 NFRC 0 New Architectural Windows Living Greatroom 16 Window 65.1 0.460 NFRC 0.39 NFRC 180 New I Architectural Windows Living Greatroom (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len I Ri ht Fin H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 None 1.00 9 Bug Screen 0.76 10 _Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 �� - _ ilk VA I 13 Bug Screen 0.76 t -T 14 Bu Screen 0.76 • Ca P[= e D 15 Bug Screen 0.76 16 IBug Screen 1 0.761 1 1 WT -3- 757P- r"My S7FRIJCTION FOR 60-N- EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:94:00 ID: Pa • e 8 of 29 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511012013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit7yExterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Wall 68 0.069 R-21 135 90 New 4.3.1-A6 Living Greatroom Door 24 0.500 None 135 90 New 4.5.1-A4 Living Greatroom Wall 363 0.069 R-21 180 90 New 4.3.1-A6 Living Greatroom Wall 487 0.069 R-21 270 90 New 4.3.1-A6 Living Greatroom Slab 436 0.730 None 0 180 New 4.4.7-A1 Living Greatroom Slab 1,090 0.730 None 0 180 New 4.4.7-A1 Living Greatroom Roof 657 0.026 R-38 0 20 New 4.2.1 A9 Casita Wall 178 0.069 R-21 0 90 New 4.3.1-A6 Casita Wall 373 0.069 R-21 135 90 New 4.3.1-A6 Casita Wall 214 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 381 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 275 0.730 None 0 180 New 4.4.7-A I Casita Slab 382 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 80.0 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Living Greatroom 18 Window 80.0 0.460 NFRC 0.39 NFRC 0 New Architectural Windows Casita 19 Window 3.8 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Casita 20 Window 3.8 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Casita 21 Window 5.3 0.460 NFRC 0.39 NFRC 180 New Architectural Windows Casita 22 Window 39.0 0.460 NFRC 0.39 NFRC 180 New Architectural Windows Casita (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Right Fin Len Hot LExt RExt Dist Len Hat Dist Len Hot 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 tw "�" .YDI1. EnergyPro 5.1 by EnerqySoft User Number.- 6712 RunCode: 2013-05-10709:44:00 _ ID: BY a 9 of 29 0 �J CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CFA R Project Name Duffield Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511012013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,287 14,929 HVAC 2 Gallery Entry Office 1,167 13,537 HVAC 3 Living Greatroom 1,526 19,228 HVAC 4 Casita 657 7,227 Totals 4,637 0 01 0 HVAC SYSTEMS System Name Qty.. Heating Type Min. Elf. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 3 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE S lit Air Conditioner 17.7 SEER Setback New HVAC DISTRIBUTION System Name Heatina Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented i 8.01 New HVAC 4 1 Ducted I Ducted JAttic, Ceiling Ins, vented 1 8.01 EI New WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Bradford -White #MN -1-100 1 Large Gas All Pipes Ins 85,000 100 0.99 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length n 0 75ro v,�ipe— a — rr S stem ame, _ ,Lengthl I JQiaTearThick. Insul. O HP Plenum Outside Buried ❑ I M lig I XA 11- ,-4- n ❑ `%. V` ❑ I F�(� r;�w t a EnergyPro 5.1 9-Y EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: a of 29 UH 1 C �--- 0 C MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Duffield Residence Date 5/10/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. .*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: _.§1 10-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 4150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of -recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(i)3A: Insulation is protected from damage, including that due to sunlight, moi tur a 'merit -maintenance �arid wind §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes h v pbr retardant or, iis,encloseVk?nM '�, ► Itl (`Ij.-' i 6..3A conditioned space. 1 pt! � 1 50 ' 4: Solar water-heatingsystems and/or collectors are certified b the Solar Ratingand Certif catjon, o Q M FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09*00 ID: Page_1 I of 29 UH 1 C �— • n � J MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Duffield Residence 1511012013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 6150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. •§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction ,and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ..programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). -.§1 50 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. GF LA QUINTA N G & SAFETY DEPT. FI OVER EneryyPro5.ibyEnergySoft User Number. 6712 RunCode:2013-05-10709:44:00? FlD;oi' STRUC I 10 Wage12o 29 DATE BY r_'9 LJ C-1 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Duffield Residence 5/10/2013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less .than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more -dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or.bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no =more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable :requirements of Sections 130, 131, 134, and 146. .§150(k)M Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ..dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION EnergyPro 51 by EnergySoR User Number., 6712 RunCode: 2013-05-10T09:44:00 ID: 13 of 29 • C, -HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Duffield Residence Date 5/10/2013 System Name HVAC 1 Floor Area 1,287 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 692 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 13,646 2,045 372 16,152 Total Output Btuh 71,000 o Output Btuh/s ft 55.2 788 794 Cooling System 01 0 Output perSystem 47,000 0 0 0 0 Total Output Btuh 47,000 0 788 1 15,221 2,045 0 Total Output ons 3.9 794 Total Output Btuh/s ft 36.5 Total Output s ft/Ton 328.6 1 17,740 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ANB748/58CVX090 33,122 4,517 71,000 Airflow cfm/s ft 1.24 Airflow cfm/Ton 408.5 Outside Air % 0.0% Total Adjusted System Output 1 33,122 4,517 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 1 71,000 Outside Air cfm/s ft 0.00 -Note: values above given at ARI conditions Jan 1 AM -HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 113 OF Heating Coil Supply Fan 1,600 cfm 113 ° F ["ROOM 72 OF ,_COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70!58°F 70/58°F 51/50°F 51/50°F Cooling Coil Supply Fan °F 1,600 cfm. ..................... CITY- .2 IIA " r_py �! ilk.'®IN`a `yY ���q - 70 / 54 OF CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09:44:60 /D: o __Pagek4 of 29 C • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Duffield Residence Date 5/10/2013 System Name HVAC 2 Floor Area 1,167 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 1,242 21,135 1,891 395 Return Vented Lighting 0 Return Air Ducts 1,220 Return Fan 0 Ventilationo 0 0 0 Supply Fan 2,978 Supply Air Ducts 1,220 TOTAL SYSTEM LOAD 1 26,553 1,891 PEAK Heating System Sensible Output perSystem 89,000 17,824 Total Output Btuh 89,000 Output Btuh/s tt 76.3 876 -Cooling System 0 Output perSystem 57,500 0 Total Output Btuh 57,500 -2,978 Total Output ons 4.8 876 Total Output Btuh/s ft 49.3 Total Output s ftfron 243.5 16,598 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/ 58CVX110 39,451 6,912 89,000 Airflow cfm/s ft 1.71 Airflow cfm/Ton 417.4 Outside Air°/, 0.0% Total Adjusted System Output 39,451 6,912 89,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM Outside Air cfm/sqft 0.00 ' Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm - 72 of 72 OF 113 OF 115 °F Heating Coil Supply Fan 2,000 cfm 114 F ROOM 72 OF 1 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 71 /59°F 71 /59°F 52/51 OF 53/52°F Cooling Coil Supply Fan 5 of / /� ..............`... CITY f 050 7 �oA t�I� 2,000 cfm FBU DING & SFS �TY E 70/5 °F F01-1 CONSTRUCTION EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-05-10709:44.;00 ID: \/ Pg415 of 29 • C� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Duffield Residence Date 5/10/2013 System Name HVAC 3 Floor Area 1,526 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 1,234 20,975 1,950 562 Return Vented Lighting 0 Return Air Ducts 1,211 Return Fan 0 Ventilation F 0 0 0 0 Supply Fan 2,978 Supply Air Ducts 1,211 TOTAL SYSTEM LOAD 26,37a 1,950 PEAK Heatin_q System Sensible OutRut perSystem 89,000 25,152 Total Output Btuh 89,000 Output Btuh/s ft 58.3 1,236 System 0 -Cooling Output perSystem 57,500 0 Total Output Btuh 57,500 -2,978 Total Output ons 4.8 1,236 Total Output Stuh/s ft 37.7 Total Output s ft/Ton 318.5 24,646 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/ 58CVX110 39,403 6,973 89,000 89,000 Jan 1 AM Airflow cfm/s ft 1.31 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 39,4031 6,9731 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 0 cfm 71 OF 71 OF 113 OF 115 OF t Heating Coil Supply Fan 1140F 2,000 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm .4 71 /59°F 52/51 OF 53/52°F Cooling Coil Supply Fan 54 / 52 OF 2,000 cfm ?�50.1,8oA 18,QQTCITY ,71159°F t BUI( ��c8x S,"iFET t 70/ 9°F 4s v (r t uR CONSTRUCTION EnergyPro 5.1 by EnergySoR User Number.' 6712 RunCode: 2013-05-10T09:44:00 /D: Pae 16 of 29 w C, J • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Duffield Residence 5/10/2013 System Name Floor Area HVAC 4 657 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 415 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 1 COOLING PEAK COIL HTG. PEAK .Heating System Sensible Latent CFM Sensible Output perSystem 71,000 8,216 1,040 219 12,746 Total Output Stuh 71,000 0 Output Btuh/s ft 108.1 474 626 Cooling System 0 0 Output perSystem 35,000 0 0 0 0 Total Output Btuh 35,000 0 1,040 0 Total Output ons 2.9 474 626 Total Output Btuh/s ft 53.3 Total Output s ft/Ton 225.3 9,165 1 13,999 Air System " CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Alrflow (cfm) 1,200 Carrier 24ANB736/58CVX090 24,699 3,255 71,000 Airflow cfm/s ft 1.83 Total Adjusted System Output 1 24,699 3,255 1 71,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P MI F Jan 1 AM Alrflow cfm/Ton 411.4 Outside Air % 0.0% Outside Air cfm/ ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 127 OF 127 OF Outside Air ^ 0 elm Heating Coil Supply Fan 127 °F 1,200 cfm -"'In .ROOM 72 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 70/58°F 51 /50°F 51150°F Outside Air Ar 0 cfm Cooling Coil Supply Fan 51 / 50 OF 1,200 cfm..................................................... 48fi7'°,o oo T C1 CJi r� 70/58°FBUIL�,� 1r`r 8, SAFETY D 0/68 F # FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page 7 of 29 DATE _ — BY • 0 ROOM LOAD SUMMARY - - . Residence .. i Name HVAC 1 -FloorSystem 1,287 ROOM LOAD SUMWRY eek r�nM-�PAM M • • ROOM LOAD SUMMARY Project - 'Duffield '- .511012013 Date System Name HVAC .. 1,167 ROOM LOAD SUMMARY ■■_ W_ , 1� Total includes ventilation loa. PAGE • .1,„242, �•-;,21;;1,35= 1 TOTAL ,?1,242 ,� 2 �351 z .. - 395 17,824 395 17,824 • 0 ROOM L•SUMMARY ProjectDate Duffield Residence i Nam6 HVAC 3 FloorSystem 1, 526 ROOM LOAD SUMMARY -Living Greatroom PAGE TOTAI�7A N WI I® • • C, ROOM LOAD SUMMARY Project Name Duffield Residence �• 219 12, 746 Date 5/10/2013 System Name HVAC 4 Floor Area 657 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Casita Casita 1 415 8,216 1,040 415 8,216 1,040 219 12,746 A ot ' Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL' i11 t9•R �.� ''-1..iii i 1 1 415 � 219 12,746 414, 9716", -) f vt i I�VIVS I tf I I Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2013-05-10T09:44i00 ID: Pae 1 of 29 DATE BY 0 � , 04 �• 219 12, 746 • 0 • ROOM HEATING PEAK LOADS Project Name Duffield Residence Date 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,287.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 1,285.6 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X �e-2,/ AT OF Btu/hr 46 = 1,538 46 = 19 46 = 3,377 46 = 4,422 46 = 3,459 = = = = = = = = = Page Total 12,815 G,p' X t p �6w3,337Schedule sd7� & SAFETY DEP . ...r R-38 Roof(R.38.2x 14.16) 0.0260 Solatube Skylight 1.4 X 0.3000 R-21 Wall (W.19.2x6.16) 1,064.0 X X X X X X X X X 0.0690 Architectural Windows 209.0 0.4600 Slab -On -Grade perim = 103.0 0.7300 X X X X X X X X X X X X X X X X X X X X through an interior surface to X 1,287 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Air Sensible Fraction another room 11.60. Height (`® v BUIL�?1?,S TOTAL HOURLY HEAT LOSS FOR ROOM 1,,152 FtJi CC)NSTRUU1I Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page 22 of 29 • 0 0 ROOM HEATING PEAK LOADS Project Name Duffield Residence Date 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Gallery Entry Office Floor Area 1,167.0 f 2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT *F R-38 Roof(R. 38.2x 14.16) 1,165.6 X 0.0260 X 46 Solatube Skylight 1.4 X 0.3000 X 46 R-21 Wall (W.19.2x6.16) 1,030.7 X 0.0690 X 46 Wood Door 24.0 X 0.5000 X 46 Architectural Windows 277.3 X 0.4600 X 46 Slab -On -Grade perim = 110.0 X 0.7300 X 46 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (") denote conduction through an interior surface to another room Page Total Infiltration:[ 1.00 X 1.064 X 1,167 X 1160-X' 0`,0 :1, I Schedule Air Sensible Area Ceiling Height C A6, ( eT Fraction BUILDING, &SAI=ETY = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 1,394 19 3,271 552 5,868 3,694 14,798 4e6 - 3,026 ' `" J DEPT. TOTAL HOURLY HEAT LOSS FOR ROOMJ V Lm 17,824 i ,=J=�c0,,4S-VHUU I ION I Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page E3 of 29 C] • ROOM HEATING PEAK LOADS Project Name Duffield Residence Date 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Greatroom Floor Area 1,526.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT OF Btu/hr 1,526.0 X 0.0260 X 46 c 1,825 1,289.9 X 0.0690 X 46 = 4,094 445.1 X 0.4600 X 46 _ 9,418 24.0 X 0.5000. X 46 c 552 perim = 158.0 X 0.7300 X 46 = 5,306 X X = X X X X = X X X X = X X = X X X X X X X X = X X = X X X X X X = X X X X = X X X X = X X = X X = X X = X X X X X X X X = X X through an interior surface to another room Page Total 21,195 X 1,526 X 12.60,-X, 3,957 Area Ceiling Height QH "'dT` BUILOI' & J�FETY DEPT. �.- icn R-38 Roof(R.38.2x 14.16) R-21 Wall (W.19.2x6.16) Architectural Windows Wood Door Slab -On -Grade Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM ' x" t�� °'— 2 152 ►-�Ji-t ��;v5r Ad Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-10709:44:00 ID: Page 24 f 29 • • ROOM HEATING PEAK LOADS Project Name Duffield Residence Date 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 657.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R. 38.2x 14.16) 657.0 R-21 Wall (W.19.2x6.16) 1,146.1 Architectural Windows 131.9 Slab -On -Grade perm = 114.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 657 X Schedule Air Sensible Area Fraction X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT OF 46 = Btu/hr 0.0260 X 786 0.0690 X 46 = = = 3,638 0.4600 X X 46 2,791 0.7300 46 3,828 X X = = = X X = X = X X = = X X X = = = X X X X X X = = = = = = = = = X X X X = X = X = X = = = X X X = X another room 11.00 X 0.289 Height ACS; = Page Total �% 60 ]'�X , DING & APPROVED 11,043 1, 04 TOTAL HOURLY HEAT LOSS FOR ROOM ; F0 1 �Ui`�j i RUG 1 10N 12,7 6 i t Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10709:44:00 I-jAID<-----57,-579 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Duffield Residence 1 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 287.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 1,285.6 X 0.0260 X 56.0 = 1,872 R-21 Wall (W. 19.2x6.16) (N) 130.0 X 0.0690 X 23.0 = 206 R-21 Wall (W. 19.2x6.16) (SE) 665.0 X 0.0690 X 31.0 = 1,422 R-21 Wall (W. 19.2x6.16) (S) 189.0 X 0.0690 X 26.0 = 339 R-21 Wall (W. 19.2x6.16) (VV) 80.01 X 0.0690 X 33.0 = 182 X X = X X = X X = X X = Page Total 4,022 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 17.5 + 1.4 X 58.1 = 81 Window (N) 0.0 X 23.7 + 100.0 X 23.7 = 2,367 Window (SE) 0.0 X 23.7 + 5.0 X 32.6 = 196 Window (SE) 0.0 X 23.7 + 49.0 X 32.6 = 1,600 Window (SE) 0.0 X 23.7 + 9.0 X 32.6 = 294 Window (SE) 0.0 X 23.7 + 30.0 X 32.6 = 979 Window 0.0 X 23.7 + 15.0 X 46.8 = 702 X + X - X + X - Page Total 6,220 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ.= 460 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 70.43 X 42 = 2,944 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,646 Latent Gain Btu/hr Occupants 2.0 Occupants X r-.--200-Btuh/nc 410 CITY OF LA QU Infiltration: x,771 X 0.94 X 70.43 x 0.00523 = BUILDING & SAFETYDEPTiA Air Sensible CFM ELA DW I v PROVED TOTAL HOURLY LATENT HEAT GAIN FOR ROOM F�.z-: �.Iv I ���' I 2,045 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-10709:44:00 P ID: Page 26 of 2 ur•, i I- -__----- - • -� - • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Duffield Residence 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Gallery Entry Office Outdoor Dry Bulb Temperature 112 OF Floor Area 1,167.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 1,165.6 X 0.0260 X 56.0 = 1,697 R-21 Wall (W. 19.2x6.16) (SE) 306.0 X 0.0690 X 31.0 = 655 Wood Door (SE) 24.0 X 0.5000 X 31.0 = 372 R-21 Wall (W. 19.2x6.16) (S) 361.7 X 0.0690 X 26.0 = 649 R-21 Wall (W. 19.2x6.16) (KO 363.0 X 0.0690 X 33.0 = 827 X X = X X = X X = :J X X = Page Total 4,199 Items shown with an asterisk (') denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 17.5 + 1.4 X 58.1 = 81 Window (S) 0.0 X 23.7 + 5.3 X 23.8 = 126 Window (S) 0.0 X 23.7 + 32.0 X 23.8 = 760 Window W 0.0 X 23.7 + 80.0 X 46.8 = 3,746 Window (W) 0.0 X 23.7 + 80.0 X 46.8 = 3,746 Window (W) 0.0 X 23.7 + 80.0 X 46.8 = 3,746 X + X - X + X - X +1 X - Page Total 12,206 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 63.86 X 42 = 2,669 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,135 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuhh//occ. 400 Infiltration: 4,771 D p= D D CITY a"fF L.V� X 0.94 X 63.86 X 0.00523 _ MEZ 491 Air Sensible CFM ELA AW �(-ii�_�'� 1'z •SAFETY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ;, aT - I 1. .91 Ene Pro 5.1 6 Ene Soft User Number.- 6712 RunCode: 2013-05-10709:44:00 ID: Pa a 27 0 29 IDATE BY I .7 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Duffield Residence 1 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Greatroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,526.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 1,526.0 X 0.0260 X 56.0 = 2,222 R-21 Wall (W. 19.2x6.16) (N) 372.0 X 0.0690 X 23.0 = 590 R-21 Wall (W. 19.2x6.16) (SE) 68.0 X 0.0690 X 31.0 = 145 Wood Door (SE) 24.0 X 0.5000 X 31.0 = 372 R-21 Wall (W.19.2x6.16) (S) 362.9 X 0.0690 X 26.0 = 651 R-21 Wall (W.19.2x6.16) (tM 487.0 X 0.0690 X 33.0 = 1,109 X X = X X = X X I= Page Total 5,oso Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 23.7 + 120.0 X 23.7 = 2,841 Window (N) 0.0 X 23.7 + 180.0 X 23.7 = 4,261 Window (S) 0.0 X 23.7 + 65.1 X 23.8 = 1,547 Window (lM 0.0 X 23.7 + 80.0 X 46.8 = 3,746 X + X - X + X - X + X = X + X - X +1 X - Page Total 12,395 Internal Gain Btu/hr Occupants 0.0 Occupants X 23o Btuh/occ. = o Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 83.50 X 42 = 3,490 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,975 Latent Gain Btu/hr Occupants O.o Occupants X 200 -Bta-h/mop . t- /�=ZQ)7�7 oCr Infiltration: 4,771 i ti X 0.94 X 83.50 X 0.00523 = �� ",s�' 0f_ E..,A :�; OAFEIFY DERT0 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM r .: ► �� t r5 950 EnerovPro 5.1 by EnemySoft User Number: 6712 Run Code: 2013-05-10709:44:00 PID: Pa a 28 of 29 • 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Duffield Residence 5/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 657.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 14.16) (N) 657.0 X 0.0260 X 56.0 = 957 R-21 Wall (W. 19.2x6.16) (N) 178.0 X 0.0690 X 23.0 = 282 R-21 Wall (1..19.2x6.16) (SE) 373.4 X 0.0690 X 31.0 = 799 R-21 Wall (W. 19.2x6.16) (S) 213.7 X 0.0690 X 26.0 = 383 R-21 Wall (W. 19.2x6.16) (1M 381.0 X 0.0690 X 33.0 = 868 X X = X X = X X = X X = Page Total 3,289 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 23.7 + 80.0 X 23.7 = 1,894 Window (SE) 0.0 X 23.7 + 3.8 X 32.6 = 124 Window (SE) 0.0 X 23.7 + 3.8 X 32.6 = 124 Window (S) 0.0 X 23.7 + 5.3 X 23.8 = 126 Window (S) 0.0 X 23.7 + 39.0 X 23.8 = 927 X + X - X + X - X + X - X + X - Page Total 1 3,195 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 35.95 X 42 = 1,503 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,216 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 35.95 X 0.00523 -� 7--,f Air Sensible CFM ELA AW & SAFE TOTAL HOURLY LATENT HEAT GAIN FOR ROOM EnemvPro 5.1 by Ene SoR User Number: 6712 RunCode: 2013-05-10709:44:00 1a Page 29 of 29 `E3gctronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 'Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/10/2013 Project Address 78-331 Deacon Drive Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,637 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If YeS,•A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,634 Radiant Barrier New Wall Wood Framed R-21 4,531 New Slab Unheated Slab -on -Grade . None 4,637 Perim = 485' New Door Opaque Door None 48 New FENESTRATION; ' iU- Exterior Orientation...._.Area ctor SHGC Overhang Sidefins Shades Status Skylight 1.4 7- 0.300 0.30 none none None New l: Rear(N) : _ .:.. 480.0 0 460 , „ ' 0 39none none .. - - Bug Screen New Right (SEj , : 101.6 0 4600 A 39 none noneyBug Screen New �r Left (MX335`0 , 060 0 39�nohe }' ` .none Bug Screen,„ 4 New -.: ,.. Skylrght `; w1 New;; . Front,(Aj f746 7� 39none r'?`�norie � Bug�Screen�f ti_ d.. j ti HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location -V e t tus HVAC 1 Ducted Ducted Attic, Ceili In�g18. e HVAC 2 Ducted Ducted Attic, Ceilint9Ins vented�t�t(� & SAW 'N'eKA HVAC 3 Ducted Ducted Attic, Ceiling Ins; ventedNew �ga �$ CTI WATER HEATING inCOMgTR Ot . Type Gallons Min. Eff Distribution StJos 1 Large Gas 100 0.99 All Pipes Ins R �New— Ene Pro 5.1 bAEhSg^ nNer Number: 6 12 RunCode: 2013-05-10709:44:00 ID: Pae 1 H8 Reg: 213-N0028242C-000000000-0000' Regi*ration Date/ Time: 2013/05/10 11:10:06 CI "Y Z' L:� (�UINTA C0^ N DEVELOPMENT � HERS Provider: CalCERTS, inc 3 Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Duffield Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/10/2013 p3 Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Stories 78-331 Deacon Drive Lot 14 La Quinta CA Climate Zone 15 4,637 n/a 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special k Construction Type Cavity ( Features see Part 2 of 5 Status R FENESTRATION:;:'`' U- Exterior .:. Orientat on.........,,Area F � actor SHGC Overhang Sidefins Shades Status 4", t IN ARM. M hX»..� .. .. �.,x..'. .............. ... ..... ..... ......... ...... r _ r -. :j.r r•-5 ''E _. . 3':: Ef :I ............ r HVAC SYSTEMS -- Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 17.7 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Di rie-A tbeA oF LA QUINTAa us � Ty t r,►t�it; SA ' ' vn Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-05-10T09:4 .:00 ID: Pa 2 of 8 'Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013/OS/101t11�1T00 P nc Riectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 Electronically Signed at CalCERTS.com by Jody. Jones (Jody Jones Development Corporation) 5/14/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Duffield Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 1511012013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White #MN-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 667.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 620.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 341.0 ft2 Covered Slab Floor, 3.500" thick at Gallery Entry Office HIGH MASS Design - Verify Thermal Mass: 826.0 ft2 Exposed Slab Floor, 3.500" thick at Gallery Entry Office The HVAC System. HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air; flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify TheiinalfMass: 436.0 ft2 Covered Slab Floor, 3.500" thick at Living Greatroom HIGH MASS Design - Verify Thermal'Mass: 1,090.0 ft2 Exposed Slab Floor, 3.500" thick at Living Greatroom ... ............. _ The HVAC System HVAC 4 must semi only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the airifiow, re. uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. H/GHMASS ilesignVenfy Thermal:.Mass 275 0£ft2 GoveredSlab?Floor 3 500 thicket Casrt €;7.. HIGH IWASS Design - Verify Thermal'Mass 382`0`ft2 Exposed Slab Floor 3.500 'thick at1Gasita ° ra 3 - HERSFREQ;UIRD�IERIFICTIU Items n;thls secbon5requlre field testing andlor venflcat)on by a certified'HERS Mater! :., The InSpector.musVrecelve a -rte R form for eacf of the.measUres:hsted below for final at even: cofnleted GF 4' ' 'f` l' ac ' The Cooling System":Carrier 24ANB748158CVX090 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of.:.the,correct_Condenser The HVAGSystem HVAC 1;incorpoil tes HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incgrpoiatds HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria;; The Cooling System Carrier 24ANB760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB760158CVXI 10 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB736158CVX090 includes credit for a 13.7 EER Condenser. A certified HERS rater mus the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a @hargQ a l�dicator pis�lay y l� g DEP - c T - The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field v t cgignn 1,6', iagriostic tdst�ingd is.requ ed to ven that duct leakage meets the specified criteria. �r n `� ����� 1 UC FOR Erie Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-05-10 09:44:0x0 D: Pa e 3 of 8 Reg: 213 -000000000-0000 Registration Date/Time: 2013/ 0;5�1�OTfl-.10:0 i� ERTS, Inc .. Fa Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 Electronically Signed at Ca10ERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013 . I ' PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Duffield Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/10/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency 'determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Bamfer that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. Ud .: r 47 :.:�.: .� 'K.'I�i;.se�4'F.; xSl- ' `p, j f t .... HERSREQYUIR�EDy VERIFICATION �'� �t'3%�� k`sN.. A+ ' .^yW4 >�3!! C'F"' i C. • i '-#YA }tti:R.. Items In this section reGu(re f eld,iest)ng and/or �enftcatlon by a certrfled'NERS Rater PrThe Inspector.,musvrece)ve a com Ie�ted.QF 4'R form for eacFiCof,:.the:-meas.tres:aisted=below for f)rial to be even°: ...............:..._....... ...._._...._............ H iiia SAFETY DEPT. DROVE® FOR CONST I EneMyPro 5.1 bv EneMySoft User Number: 6712 RunCode: 2013-05 OT09:44:00 I Page 4 of 8 I DATE Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013./-"4 1 1'f): S Provider: Ca10ERTS, Inc .Ele.ctronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013 { � w PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Duffield Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/10/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.50 4.27 0.23 Space Cooling 59.84 53.10 6.74 Fans 11.96 16.26 -4.30 Domestic Hot Water 7.87 4.27 3.59 Pumps 0.00 0.00 0.00 Totals 84.17 77.90 6.27 Percent Better Than Standard: 7.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S)180deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,274 147 Fuel Available at Site: Natural Gas (K9 1,646 335 Raised Floor Area: 0 (N) 1,160 480 Slab on Grade Area: 4,637 (E) 1,562 102 Average Ceiling Height:._;. R. 11.8 Roof 4,637 3 Fenestration Average U -Factor: 0.46 TOTAL: 1,066 Avera a SHG;' G` 0.39 Fenestration/CFA Ratio: 23.0% REMARKS`°`-�' Traditions Country Club Lot 14 T fme., 1:- ...ss:M ..... �... STATEMENT OF COMPLIANCE ;. , This certificate comp lance lists;the building features and specifications needed to comply with Title P`arts:l.Administrative Regulations and Part 6 the Efficiency Standards of thCalfornia Code of Regulations. The documentation author her certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 5/10/2013 Address 77-085 Michigan Drive Name Tim Scott Ci /State2i Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and'recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) CITY OF LA QUANTA Company Design Mind Studios DEPT. ���� Address 74 -79442nd Ave, Suite 9 Name Gordon Stein BUILDING & City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-4488 AE Signed � V C-Niic� e # Date FOR cutis Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-10T0 :44:00 1141Page 5 of 8 vim, Reg: 21 5,1 '3-N0028242C-000,000000-0000 Registration Date/Time: 2013/010 11:10:0 HERS. RTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 Electronically Signed at CalCERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511012013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,286 0.026 R-38 0 20 New 4.2.1-A9 Master Bedroom Wall 130 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 665 0.069 R-21 135 90 New 4.3.1-A6 Master Bedroom Wall 189 0.069 R-21 180 90 New 4.3.1-A6 Master Bedroom Wall 80 0.069 1 R-21 270 90 New 4.3.1-A6 Master Bedroom Slab 667 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 620 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,166 0.026 R-38 0 20 New 4.2.1-A9 Gallery Entry Office Wall 306 0.069 R-21 135 96 New 4.3.1-A6 Gallery Entry Office Door 1 24 0.500 None 135 90 New 4.5.1-A4 Gallery Entry Office Wall 362 0.069 R-21 180 90 New 4.3.1-A6 Gallery Entry Office Wall 363 0.069 R-21 270 90 New 4.3.1-A6 Gallery Entry Office Slab 341 0.730 None 0 180 New 4.4.7-A1 Gallery Entry Office Slab 826 0.730 None 0 180 New 4.4.7-A1 Gallery Entry Office Roof 1,526 0.026 R-38 0 20 New 4.2.1-A9!Living Greatroom Wall 372 0.069 R-21 1 01 90 1 New 14.3.1-A6 ILiving Greatroom FENESTRATION SURFACE DETAILS ID Type. Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Skylight 1.4. 0.300 NFRC 0.30 NFRC 0 New Solatube Skylight Master Bedroom -2_,: Window 100.0 0.460 NFRC 0.39 NFRC 0 New Architectural Windows Master Bedroom 3 Window " = 6.0 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Master Bedroom 4,. Window 49.0 0.460 NFRC 0.39 NFRC 135 New Architectural Windows Master Bedroom 5 ' : Window,,.. _ r9.0 0.460 NFRC ,;0:39. NFRC _ 135 New _. _, „ ,Arohitectural_l Windows ,. ,..�_, Master Bedroom 6 _ . Window- "x-30:0 0.460 'NFRC,•f :. '0.39' NFRCkss„ ` _ ,__'135 New; r � 'ti Architectural Windows; � g 'Master Bedroom 7 Wndow = � 15.0 0,460 ,NFRC,,Y 0:39 'NFRC,7' ',270 ,NeW' _ Architectural, Windows., Master, Bedroom 8 Skylight, t1_ 1,0.30Q; NFRC` 0.30 NFRC "M'• 0 New_,-: � o.1atu6ejSkylight: _ Ga11ery Entry Office, - 9 Window ,5.3 x':0:460 NFRC'' 0.39 NFRC '. 180 ,New : -' 'Architectural Windows N Gallery;Eptry Office . 10 Wndow ,f32.0; ,,ir;„0.460. NFRC.;; - 0.39`-'NFRC,, Architectural Windows } Gallery '_Entry' ;Office 11 ,: Wndow 1 %, 80.0 ;,'°0:460 NFRC`: X0'39: "NFRC;-.1180 New ArchitecturaLWindows ---� . Gallery Entry+Office 12:; Window , :; . .80:0 , 0.460 NFRC 0.39 NFRC New. Architectural -Windows ` 'Gallery Entry Office 13 Window W 80.0 0.460 NFRC `' 0.39 NFRC New Architectural Windows GalleryEnt Office ,'`14. window 120.0 0.460 NFRC 0.39 NFRC New Architectural Windows Living Greatroom 15 Window 180.0, 0.460 'NFRC 0.39 NFRC New Architectural Windows Living Greatroom 16" Window 65:'1; ',._.0.460, NFRC 0.39 NFRC New Architectural Windows Living Greatroom (1) LI -Factor Type: , :;,,,,11,6-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: ".1'16 B efault Table from Standards, NFRC =Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin Hat Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 None 1.00 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.761 QTV 16 IBug Screen 0.761 1 l i I I ski pt •.)!-31 L-; I I 2F)P,0VED EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10;f09:44: 0r -sr -3 r-1D•t " Pa e 6 of 8 Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013/05/10 11:10: 6 RS o ider: Ca10ER S, inc DATE Electronically Filed by Tim Scott and Authenticated Electronically Signed at CalCERTS.com by Jody Jones at CalCERTS.com - 5/14/2013 (Jody Jones Development Corporation) 5/14/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Duffield Residence Building Type m Single Family 13 Addition Alone O Multi Family O Existing+ Addition/Alteration Date 1511012013 OPAQUE SURFACE DETAILS Surface Ll- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 68 0.069 R-21 135 90 New 4.3.1-A6 Living Greatroom Door 24 0.500 None 135 90 New 4.5.1-A4 Living Greatroom Wall 363 0.069 R-21 180 90 New 4.3.1-A6 Living Greatroom Wall 487 0.069 R-21 270 90 New 4.3.1 A6 Living Greatroom Slab 436 0.730 None 0 180 New 4.4.7-A1 Living Greatroom Slab 1,090 0.730 None 0 180 New 4.4.7-A1 Living Greatroom Roof 657 0.026 R-38 0 20 New 4.2.1-A9 Casita Wall 178 0.069 R-21 0 90 New 4.3.1-A6 Casita Wall 373 0.069 R-21 135 90 New 4.3.1-A6 Casita Wall 214 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 381 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 275 0.730 None 0 180 New 4.4.7-A1 Casita Slab 382 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE:DETAILS ID Type Area lJ-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 80.0. 0.460 NFRC 0.39 NFRC 270 New Architectural Windows Living Greatroom 18_,: Window 86.0 0.460 INFRC 0.39 NFRC 0 New Architectural Windows Casita ..119 Window"'` 3.8 0.460 "NFRC 0.39 NFRC 135 New Architectural Windows Casita 20. Window 3.8. 0.460 NFRC, 0.39 NFRC 135 New Architectural Windows Casita 21:y Window-� - _... „ 5.3 0.460 NFRC w5 _0 39: NERC 1.8,0. New....,Architectural..Windo_w,s ..�.,,:._ Casita 22 ; Window' - X39 0 0.4607 ,0 39' ;NFRC.x*v , 1,80:'New ;.' Architecturel-Wndows ?';.F Cesita -. Z� {ypss ,.s# rb . Y : �- _ ,. .4. k, £' � '+Y ...to•C°.G.. R,'i :M:.°'� f` _&-:' VOW, 111; ks%h X .: ;: 172t--'_ Y k4, -Y d.' : .:. t ;9�. t 5/`: ...'...,.. ". ✓ i �' 1"�F r'E. :: V AMM Z If ........_......:... . .........:.:::.::.: (1) 1.1 -Factor Type: ikl6-A _ Default Table from Standards, NFRC = Labeled Value 2 SHGCT e: `.1i1.67B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Ri ht Fin ID Exterior Shade Type SHGC Hat Wd Len H t LExt RExt Dist Len H t Dist Len I Hot 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Buq Screen 0.76 r L 9n aG P CA Q, �` JVED Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2013-05-10 09:44:00:(—IRI '' H U Pa e 7 of 8 Reg: 213-N0028242C-000000000-0000 Registration Date/Time: 2013/0 /10 11:1 RS ider: Ca10ERT , inc DATE - Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/14/2013 Electronically Signed at Ca10ERTS.com by Jody Jones (Jody Jones Development Corporation) 5/14/2013 t, .0 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Duffield Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511012013 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existinq Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,287 14,929 HVAC 2 Gallery Entry Office 1,167 13,537 HVAC 3 Living Greatroom 1,526 19,228 HVAC 4 Casita 657 7,227 Totals 1 4,6371 01 0 0 HVAC SYSTEMS ;;S stem Name,:";Qt : V. -Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 's Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 1 ICentral Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New v HVAC 3 _ _. 1 :. Central;Fumace`, , 760%?AFUE 'S li 'GondWoner, •; 15 0 SEER $etbaek ,.:. New FIVAC"`4, , ' 1 ;; Centr`a1�F_umac e` 80% AFUE* S IIt1Alr%Ondi Joner 1,4 Z SEER. Setback;; New ;: =" ", f. '::'c: L hex. -'.3 �.. .:_ .. F 3 p: •W: Y'"f . .. i ...: .. VIA.:'..:i.: �"s - oX. ..T�¢�F,.•C.. '4 ..Ssi.Y-:ajy,'.. ii.e..i HVAC DISTRIBUTION -z` . ,.: :t�srv', ....._ ._`.. :: ; ^.A,;W...``�r , .._. =k1. F , , Duch Ducts?, S stem Narne .r .. ea in :...:Cool�n ..._ ... _.. Duct.LocationE R.Value Tested? Status HVAC 1;,gf, Ducted I_ Ducted Attic, Ceiling Ins, vented 8.0 m New Ducted `' Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC3 `_ - Ducted i.,.. Ducted Attic, Ceiling Ins, vented 8.0 El New Y _ HVAC 4 li % _Ducted0 Ducted Attic, Ceiling Ins, vented 1 8.01 ❑ New ❑ WATER HEATING SYSTEMSP:' S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White #MN -1-100 1 Large Gas All Pipes Ins 85,000 100 0.99 0.00 % 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 i� v a `- Pipe System Name Length Pipe Insul. Diameter Thick. Q HP Plenum Outside Buried ❑ 1 ° I e 1 C 4 BUILDINGSAF"11_1 , -9-1 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-10T09:44:00 1" IDI) i .'� L.�, N ``: k," Tf e 8 of 8 )I CTION Regi 213-N0028242C-000000000-0000 Registration Date/Time: 2013/05/1LD.6* 10:106O(';�i: Cal RTS, nc TE Via-