BPOL2015-0182 Plansfm = 1500 pal.
8" C.M.U., TYPICAL
PLASTER
OVER C.M.U.
TYPICAL
#3 BARS
12" O.C., EACH WAY.
J
3 1/2" EMBEDMENT & FILL
PITH EPDXY TYPICAL
EXISTING SPA OR POOL—
#3 BARS ® 12" O.C.
3 1/2" MIN. EMBEDMENT
& FILL WITH EPDXY TYP.
#3 BARS ® 12" O.C. HORIZ. AND
DOWEL INTO POOL 0 EDGE OF
SEAT WITH 3 1/2" MIN.
EMBEDMENT & FILL WITH EPDXY.
SEE NOTE #2.
r
ADD STEPS, BENCH OR SHELF
#3 BARS ® 8" O.C. E.W.
AND DOWEL INTO FLOOR &
SIDE WALL WITH 3 1/2"
MIN. EMBEDMENT FILL
WITH EPDXY.
n
EXISTING POOL FLOOR.
n
8" MIN. GUNITE-
OR 8" C.M.U.
(fm=1500 p.s.i.)
PLASTER OVER —
GUNITE OR C.M.U.
3 1/2" EMBEDMENT AND -
FlLL NTH EPDXY TYPICAL
A ] ADD A DAM WALL
GUNITE WALL USE #3
® 6" O.C. EA. WAY 0
C.M.U. WALL USE #3
8" O.C. EA. WAY AND
DOWEL INTO FLOOR &
SIDE WALL WITH 3 1/
MIN. EMBEDMENT FILL
WITH EPDXY.
EXISTING POOL
FLOOR.
SEE NOTE #2.
t
(GUNITE OR C.M.U.)
J1 -
SEE APPROPRIATE
DETAIL FOR REBAR
SPACING & GUNITE
THICKNESS.
FW
otgmeONO
NEW
5EE
REMOVE GUNITE OR CONCRETE TO EXPOSE (E) THIS DETAIL MAY BE USED FOR
REINF. STEEL EACH SIDE OF REMOVED AREA THE FOLLOWING:
FOR LAP SPLICE WITH NEW REINF. 1. REMOVE AND REPLACE FLOOR.
LAP LENGTH: j3 BAR - 15 INCHES
/4 BAR - 20 INCHES 2. REMOVE AND REPLACE WALL
/5 BAR - 25 INCHES 3. ANY COMBINATION OF 1 & 2
B LAP SPLICE & REMOVE AND REPLACE GUNITE DETAIL rd
REMODEL NOTES:
'
1. EPDXY TO BE SIMPSON STRONGTIE
SET -XP EPDXY ADHESIVE OR EQUAL.
INSTALL PER MANUFACTURERS
SPECIFICATIONS (ICC REPORT ESR -2508,
L.A. RR# 25744).
2. BONDING TO EXISTING SURFACE:
A. EXISTING SURFACES MUST BE
SOUND, FREE OF DEFECTS. CLEAN,
AND FREE OF BOND INHIBITING
no
MATERIALS.
co
o
B. EXISTING SURFACES SHALL BE
o
ROUGHENED BY CHIPPING OR
OTHER SUITABLE MEANS TO PROVIDE
W > '`
o
OPEN PORE STRUCTURE. ALL
U Q o CD
LOOSE, CRACKED, OR DETERIORATED
= M
MATERIALS SHALL BE REMOVED.
C. CLEAN EXISTING SURFACES BY
s H v
WATER BLASTING.
m Z
D. SATURATED SURFACE DRY CONDITION
-j
OF THE SUBSTRATE SHALL BE
o N c m
t
MAINTAINED PRIOR TO APPLYING
Q LL
a
MATERIALS.
E. WHEN APPLYING MATERIALS OTHER
THAN WET -MIX SHOTCRETE OR
DRY -MIX SHOTCRETE (GUNITE),
CEMENT PASTE OR OTHER BONDING
0) V
AGENTS SHALL BE BRUSHED ONTO
c:
THE SUBSTRATE FOR ABSORPTION
i •—
INTO PORE STRUCTURE.
F. BONDING MATERIALS ARE NOT
0)
RECOMMENDED FOR WET OR DRY
c
MIX SHOTCRETE.
3. USE GRADE 40 REINFORCING STEEL.
4. IF REINFORCING SHOWS SIGNS OF
d a)
EXCESSIVE DETERIORATION (RUST), CUT
EXISTING REINFORCING 6" PAST
DETERIORATION SECTION & LAP WITH NEW
STEEL 24" MIN.
EXISTING POOL REINFORCEMENT &WALL
THICKNESS PER STANDARD
POOL STRUCTURAL PLAN DETAIL #7. SPILLWAY TO PROVIDE WATERFALL EFFECT TO MINIMIZE
�— —T LEAKING THROUGH COLD JOINT.
\ ALTERNATE:
EXPOSE 24" MIN. OF EXISTING
OPTIONAL REINF. AND LAP 24" WITH NEW PORTION OF EXISTING STEEL & BOND BEAM z
BENCH 1 REINF. PER DETAIL �C MAY BE REMOVED TO PROVIDE MIN. SPA tFSS10A/ 0 g
— WALL THICKNESS (NO STRUCTURAL SPA MAY BE 18" Q F (n U d
CONNECTION BETWEEN NEW SPA & POOL). MAX. RAISED OVER �ic,0 R J. B w z Q
i I #3 BARS ® EXISTING POOL tib' Z z
12" O.C..
i ( DOWEL INTOFLOOR & a— O O U
SIDE WALL #3 BARS ®12" O.C. W/ NEW SPA DAM = w Y Z
_ 3 1/2" MIN. EMBEDMENT & #3 BARS ®12" WALL MUST LAP \Q z p N
` UNDISTURBED SOIL G M TH N 3 1/2" FILL W/EPDXY. O.C. EA. WAY. OVER EXISTING POOL I O�� 3 o N JO
1,500 PSF MIN. EMBEDMENT WALL TO FACILITATE Lc0 Cp\\F � O O
BEARING VALUE 1I & FILL WITH w `� WATER -PROOFING. PROVIDE FLEXIBLE MASTIC J
11III z w0
CL
EPDXY. ® TILE OR GROUT UNE. O Z m o
REMOVE EXISTING 3 I cn ]I o ce w m
POOL WALL BEND ` a0 #2. 'I ' #3 BARS Z L BAq(-FlU Q � __ z
EXISTING WALL REINF. ? � SEE NOTE #2. SEE STANDARD STRUCTURAL (ISj1t�G.20QL _ ��I z z a V)
INTO NEW SPA Q ®12" O.C. PLAN FOR SPA WALL r if t • ��rQ�
Lo
FLOOR, LAP 24" MIN.
VERTICAL EXISTING GUNITE POOL BUILDING &SAFETY z z cn
OA O 1 /03/ 14 a�'-, m
SEE NOTE #2. D
BACK -FILL TO BE COMPACTEDL APPROVE A "CS BY: C.J.B.
TO 90%SLURRY
RELATIVE DENSITY. CREATE HOLE FOR FOR CON CHEC ED BY: R.L.L.
' SLURRY MIX OR PEA GRAVEL DRAINAGE. UCTIO
RECOMMENDED.
HORIZONTAL BARS TO HAVE
3%- MIN. EMBEDMENT INTO X MIN. EMBEDMENT POOL & SPA
SIDE POOL WALL, TYPICAL & FILL WITH EPDXY TYPICAL
REMODEL DETAIL
ADD SPA OR SHELF PARTIALLY INSIDE POOL C D ) RAISE FLOOR OF EXISTING POOL
' rEl ADD A SPA
(OUTSIDE EXISTING POOL) L F
DETAIL #640
Azure Pools & Spas Inc.
P.O. Box 10641
Palm Desert, CA 92255
760-322-7665
a Rencc «azurepoolsandspaacom
LIC# C-53, 802919
DAVIDSON
RESIDENCE
REAR PROPERTY UNE
FIRE BOWL Existing awn
( TWO PLACES) 10'
see attached photos +12" +18 +1 "
9'
c:� o
C>t l
Existing pool and spa
INSTALL NEW -
6' WIDE
RAINFALL ;
Existing lawn
ADDRESS: 78-381 DEACON DR. WEST 1
CITY: LA QUINTA
J
I "=8' SCALE o
EXISTING PATIO TO
a, REMAIN INTACT
SCOPE OF WORK:.
1. Remove existing stamped concrete
2. Remove interior pebble and the
3. Remove existing stacked stone
water feature and rocks behind it on
back - center of pool
4. Add tanning shelf to pool where
indicated on plan
5. Add new 6' wide rainfall cascade
on back of pool with fire / water
bowls on each side
6. Install new patio (in same area as it
was removed) covered in random
Quartzite stone
7. Install new Variable speed pool
pump
S. Install new LED lights
9. Install new filter and salt system
10. Install new file - see attached
11. Install neve Pebble Tec interior -
Midnight Blue
NEW TANNING LEDGE
WITH 1( SLEE EMBRELLA
FY OFQUINTA
WING &IFEN DEPT.
OPPRED-
OR CONnTinkr
NEW RANDOM STONE
DECKING
approx. 1,640 sq. ft. in
same area a decking
removed.
Stone: Quartzite
Color: Birch Creek
FY OFQUINTA
WING &IFEN DEPT.
OPPRED-
OR CONnTinkr