05-4972 (SFD) Title 24N I .. TITLE 24 REPORT i Title 24 Report for: RESIDECENCE DEACON WEST 78401 DEACON WEST LA QUINTA, CA Project Designer: DAVID YORK; ARCHITECT #12 W. AVE. SAN GABRIEL SAN CLEMENTE, CA 92672 (949)429-5591 CITY OF LA QUINT BUILDING & SAFETY DEPT. APPROVED FOR CONSTR TION 12 DATgb(, - Sc DEC 2 3 2005 Prepared By: DAVID -YORK livid York, Architect lest Ave. San Gabriel Clemente, CA 92672 (949) 887=8034 Job Number: DEACON WEST Date: 12/18/2005 A The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energpoft.com. EnergyPro 4.0 by EnergySoft Job Number. DEACON WEST I User Number. 3715 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary 1 2 3 8 10 11 EnergyPro 4.0 by EnergySoft Job Number. DEACON WEST User Number. 3715 Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R RF IDFC.,E[1LCF pF Project Title CON WF$T ft2 Watl Wood 520 0.069 R-21 R-0-0 Wall Wood 150 0.069 R-21 R-0.0 12/18/2005 Date 78401 nFACON WEST Project Address I A QI JINTA n/a ft2 Building Permit # Daviel York ArrhitPrt Raised Floor Area: 0 (949) 887-8034 Fuel Type: Documentation Author Natural Gas Slab on Grade Area: Telephone plan Check/Date FneraVPro Cornpillfice Method 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance Number of Dwelling Units: (kBtu/sf-yr) Design Design Margin SHGC: 0.33 Space Heating 1.47 1.19 0.28 INFORMATION Space Cooling 56.00 47.82 8.18 Fans 8.41 7.95 0.46 Domestic Hot Water 5.12 8.21 -3.09 Pumps 0.00 0.96 -0.96— Totals 71.00 66.13 4.86 Percent better than Standard: 6.9% Building Type: [k Single Family ❑ Addition Total Conditioned Floor Area: 5,016 ft2 Watl Wood 520 0.069 R-21 R-0-0 Wall Wood 150 0.069 R-21 R-0.0 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (North) 0 deg Raised Floor Area: 0 ft2 Fuel Type: _0_ 0 Natural Gas Slab on Grade Area: 5,016 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 1,222 ft2 Avg. U: 0.43 Number of Dwelling Units: 1.00 Ratio: 24.4% Avg. SHGC: 0.33 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area U OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt _0_,80 Wall Wnod 229 0.069 X21 R-0 0 Watl Wood 520 0.069 R-21 R-0-0 Wall Wood 150 0.069 R-21 R-0.0 a q 0 90 .Door None— 24 n 5n0 Mona _R n!n n _90 Wa[L-- Wood_ 672 _0 069 _R-91 _R -n.0 _9090 Wall Wood 94 0.069 R-21 R-0.0 Mill Wood 9R9 R 180 90 970 9 _0069 _B21 -n 0_ Boot Wood 4 37R 0 025 R_38 R=Q 0 _ _0_ 0 Roof Wood_ Zig _0.036 R_30 R-0.0 _0_ 0 Roof Wood 400 0.036 R-30 R-0.0 0 0 Gains Condition Y / N Status JA IV Reference Location / Comments New 09-A6 1st Fleur New 09 -AS 1st Floor New 09-A6 1st Floor New- 28-A4 15t Floor New 09-A6 1St Floor New 09-A6 1 st Floor New Q9 -A6 1gt Floor Never n1-A1R 10 Floor New 02-A9 1st Fleur New 02-A9 1st Floor EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. DEACON Page:3 of 11 WEST Certificate Of Compliance : Residential (Part 2 of 3) CF -1R RESIDECENCE DEACON WEST -_ _ -- _-- 1.2/18/2005___..___ Project Title Date FENESTRATION SURFACES Window Overhang Left Fin Right Fin Exterior Shade Type SHGC Hgt__Wd. True Cond. Hgt. Location/ # Type_ Area LI -Factor" SHGC2 Azm. Tilt Stat. Glazing Type _ __- Comments 1_. Window Font-(North)_56..0_ 6.0 -0.740 _11.6_A _0.70 11.6 _--0_ 9.0- New _I2ouble_MetaLClear _ 0.76 __ _1st-Eloor___ 2 _ Window Front North) 72.0 0.350 NFRC 0_25 NFRC 0 90 New JELD-WEN FRENCH _ 1st Floor _3_ Window Front (North)_ 19.2 0.310 NFRC 0_33 NFRC 0 90 New _JELD-WEN FIXED 1st Floor__.___. 4_- ..Window Front _-(North) 30.0 0.350 NFRC 0_29 NFRC 0 90 New _JELD-WEN OPENABLE 1st Floor_ 5_ Window Front-_1North) 9.8 0.310 NFRC 0_33 NFRC 0 90 New JELD-WEN FIXED --.1st Floor_. 6 _ indow Front_-(N�c rJb) 1Q0 0- 50 NFRC _0 3 NFRC 0- 90 New EJ LD_WENDPEN- BLE .1st Floor , 7_.YVsdow--ftont (NQ -*)---14a 0_359 NFRC - 9 -NERC _� 90 New --- - - -- _tst Floor_ ------ 8 Window -Front (North) 10.0 0.350 NFRC 0_29 NFRC 0 .90 New JELD-WEN OPENABLE 1st Floor 9_.-YV!indow-Econt.-(Nodb)_ 12.Q 0310NER-C x,33 _NERC -0 -10- New 4EU1WfbLEIXED 1siFJoor -�-- .10. VA/indow Eront..__-ft.rth) 8..q _9310_NER-C 0 33 sER-C. _0_ K blew J.EL0zffE -EIXE-D - tst.FJoor__ 11 Window Left (Eas 24.0 0.350 NFRC 0.25 NFRC 90 90 New JELD-WEN FRENCH 1st Floor -___- 12. Window ,__Left East) -36_0. 0.350 NFRC 0.29 NFRC 90 90 New JELD-WEN OPENABLE - 1st Floor _1-3. _Window_ -Left (East) ---1_41 -0.310 -NERC 9_3311ER-C -30_ 90 New JELD�I-EN-EIXED - tst.Floo.r 14 Window Left East 22.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor_-___. 15 Window_ Left _(East) 30.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE _ 1st Floor -6 Wiindow Left -(East - 30.0 _ 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE - 1st Floor..-_____ 17. Window _ Left (East) 60.0 0.350 NFRC 0.29 -NFRC 90 90 New JELD-WEN OPENABLE 1st, Floor_ 1$ Window . Left -_(East) 19.6 -0.310 NFRC -0.33 NFRC 90 90 New JELD-WEN FIXED 1st_Floor - _•. -19W �dowLeft -(EasJJ 52 0 _4.350 NERC _0_22 _NFRC ._9.9 - - -- - - - 16 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. 0.76 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin Exterior Shade Type SHGC Hgt__Wd. _ Len. Hgt. LEA -._ REA Dist. Dist. Len. Hgt. 1 _ Bug Screen 0.76 8.0 8.0 0.1 6.0 -Len -__Hgt_ _6_0 2 - Bug Screen _--- _ 0.76 8.0 5.0 -6.0 6.0 0.1 6.0 6.0 3 Bug Screen - _ 0.76 _ 3.0 5.0 6.0 0.1 6.0 6.0 _0.1 _ 4_0 -_0 _0.1 4.0 0 4 _ Bug Screen --- 0.76 - - - - -- -- - -- - 5 Bug Screen-- 0.76 6 Bug. Screen 0.76 -- --- - - -- 7 Bug Screen 0.76 -_ - 8 Bug Screen 0.76- - 9 _ -- Bug Screen .. _ ---- - 0.76 --- ---- ---- 10 Bug Screen----_--_-- 0.76 fi Bug Screen 0.76 8.0 3.0 8.0 0.1 8.0 8.0 12 ---_ Bug Screen -- - 0.76 -- _ --- -- - ---- --- 13 Bug Screen 0.76 14 --- Bug Screen 0.76 - -- - - 15 ----- Bug Screen -- 0.76 ---- -- - - - -- - - - 16 Bug Screen 0.76 Ti BugSc 0.76 18 Bug Screen 0.76 -- - 19 - ---- Bug Screen -_ 0.76 - - --- -- -- -- --- __ - - - --- - - - -- -- _-.--- - THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Type _ Length_ R -Val. Location JA IV Reference Status Slab Perimeter ___ , _ _ ---_350 _ None No Insulation__ 26-A1 Slab Perimeter 150 None No Insulation 26-A1 New Location/ Comments 1st Floor----- - - - - _~ ____ - Run Initiation Time: 12118/0511:16:51' Run Code: 1134933411 - - EnergyPro 4.0 by EnergySoft User Number. 3715 _ Job Number. DEACON - _-- - Page:4 of 11 WEST Certificate Of Comaliance : Residential (Part 2 of 3) CF -1 R RESIDECENCE DEACON WEST - 12/18/2005 Project Title Date FENESTRATION SURFACES Overhang Left Fin Right Fin__-_ # Exterior Shade Type SHGC-__- Hgt- Wd.a_ Len. Hgt. LExt. RExt. _ _ _Dist. __ Len. Hgt_ Dist. - Len. 20 Bug Screen_------- 0.76 --- --- ---- -- - --- --- -- -- -- 21 Bug Screen __-- 0.76- True Cond. 22 Bug, Screen _ 0.76 Location/ # .23 Bug Screen ___--- 0.78 Area LI_Factorl-SHGC2 Azm. Tilt Stat. Glazing Type _ _Comments -Type -- _ 20 Window--Left--(.East) -_35.0_ -0.350 _NERC. -0.29 NERC -_90_ -9.0. New`_JEl QD=WEN_QeENABLE_-__ _1st -Floor_-_- 21 Window Left _ East 40.0 0.350 NFRC 0_25 NERC 90 90 New JELD-WEN FRENCH 1st Floor 22 Window Left East 9:8 _ 0.310 NFRC 0`33 NFRC 90 90 New JELD-WEN FIXED 1st Floor 23 Window Rear South) 11.2 _ 0.350 NFRC 0.29 NERC 180 90 New _JELD-WEN OPENABLE - 1st Floor ,24 Window Rear--LSouth)- Ej4,CL 0.350 NFRC 0.29 NFRC _ 180 90 New JELD-WEN OPENABLE -1st Floor---­­ loor_------,25 25 Window-- Rear -(59-v th) 198.0 0.62Q NFRC 0.40 NFRC -18_-0 0 New FLEETWOOD DOOR 1st Floor ---_-- Z Windom%Bsat--kS9utb)___ O- A-620 A 10 -IFS X80 -20 Nem -FLEETWOOD DOOR tst1I-0Qr-__-______-___._ 27 Window Rear (South) 9.8 0.310 NFRC 0_33 NFRC 180 90 New JELD-WEN FIXED 1st Floor --_-- -- 28. Window Bear_-_(S-Qutb)- 30 Q 0.350-NER-C 0.29 BERC _ 80 --K Ne-m---JELD_WEN-0P-- -6LEl-o0.r _.___.--___-_- .29 -Window -Right ---(West)__ 48.0 _Q 350.NFRC 0.2.9 _NFRC ___27.0_ _90 N.ew .-JELD_WEN_OP.ENABLE----. 1_st_Floor _ - - . _30 Window- Right-�Wes1)- 24_Q �_310NFR_C 9-3 NF C 2Q �Q Nev---JELD-WEN FIXED _-_- 1sl.Floor_--_ 31 Window Right _-(West)- 10.0 _0.350 NFRC 0`29 NFRC 270 90 New -JELD-WEN OPENABLE___-- 1stFloor _32 Window-Right--Oldest)-36A _0.35-0_NEF3C 0.29 _NERC -270- -99 dein! JEL2WEN OP_ENAB.LE.-_ 1st -E10011-- 33 Window Rfgh est) 10.0 _0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE _ 1st Floor_•__. 34 Window Right (West) 36.0 0.350 NFRC 0.29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor__ -_- 35 _Window Rightest) 11.0 0.350 _NFRC 0.29 NFRC 270 90 New JELD-WEN OPENABLE - 1st_Floor--_-______ _••____ 36 Window Right -_West) 30.0 0.350 NFRC 0.29 _NFA 270 90 New JELD-WEN OPENABLE 1st Floor_____-_-_-__ 37 Window Right__ est) 0.350-NFRC 0.29 NFRC 270 90 New JELD-WEN OPENABLE _1st Floor--_____-_-- 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin__-_ # Exterior Shade Type SHGC-__- Hgt- Wd.a_ Len. Hgt. LExt. RExt. _ _ _Dist. __ Len. Hgt_ Dist. - Len. 20 Bug Screen_------- 0.76 --- --- ---- -- - --- --- -- -- -- 21 Bug Screen __-- 0.76- 22 Bug, Screen _ 0.76 .23 Bug Screen ___--- 0.78 24 Bug Screen -- _0.76 ___ ,_ -- --_- ---- -.--- -_- 25 Bug Screen_____-__- 0.76- _1.0. A 0 1-6-0 1 1 0 1 0 0 0 0 10 .1 4,0 1 --0 0 C _-0 4.0 26 Bug Screen ------ -- 00-76 --•-- ---- --- ----_ -.. .--- --_- --_ -__ ----- - --- 27 Bug Screen 0.76 28 Bug Screen 0.76- 29Bug Screen ----- - 0.76 -- - --- -- - _ -. - - - - - 30 Bug Screen - -_ -- -0.76 31 Bug Screen 0.76 --- - --- -- --- -- --. _. _ --- -- Ti Bug Screen 0.76- -- 33 Bug Screen _ 0.76 34 Bug Screen 0.76 -- `- __ - -- -- - - --_- --- -- 35 Bug Screen 0.76 ---- --- - - - --- --- -- --- 36 Bug Screen 0.76 -- -_-- --- - -- - -_-- - __---- _--- _-. _ - -- --- 37 Bug Screen - -0.76 -- .- _-- -- --- ----- -- - -- -- - - --- . _.-. THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val, JA IV Reference Status Comments PERIMETER LOSSES I _ Lenqth Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments `-Run Initiation Timms 12/18105 11:16:$__- RuoCodQ_1.1_3_493_3411----_-___--- EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number: DEACON WEST Page: 5 of 11 Certificate Of Comaliance : Residential (Part 3 of 3) CF -9 R RESIDECENCE DEACON WEST 12/18/2005 Project Title Date MVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback MVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated' Tank Energy Standby' Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Rheem 41VRP50PT Small Gas Recirc/No Control 2 40,000 50 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btulhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: DAVID YORK Title/Firm: DAVID YORK, ARCHITECT Title/Firm: David York, Architect Address: #12 W. AVE. SAN GABRIEL Address: 12 West Ave. San Gabriel SAN CLEMENTE, CA 92672 San Clemente, CA 92672 . Telephone: (9491429-5591 Telephone: (949) 887-8034 Lir. #: C 2-4-9 d 9 c____ (signs ure c l ` (date)' signature) P ( 'ate) Enforcement Agency Name: Titie/Finn: Address: Telephone: WEST Certificate Of Compliance : Residential (Addendum) CF -1 R RESIDECENCE DEACON WEST 12/18/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified In this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "HVAC System" includes credit for Reduced Fan Power. Fan is shown In the HERS section below. This house has reduced infiltration and/or mechanical ventilation. The homeowners manual provided by the builder must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HERS Required Verification Items In this section requirefield testing and/or verification by a certified home energy rater under the supervlslon of a CEC- approved Mens provider using cec approved testing andror verification methods and must oe reported on me cr-411 Installation certificate. Plan Field The HVAC System "HVAC System" incorporates HERS verged Dud Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC System" incorporates a HERS verified Refrigerant Charge test or a HERS verged Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System "YORK P1 DUB1 6V/CZB0421 1 " includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. This building has tight construction with reduced infiltration and a target blower door test range between 1970 and 6436 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 1970 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. DEACON Page:7 of 11 WEST Mandatory Measures Summary: Residential (Page 1 of 2) MFA R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersedes the items marked with and asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or Initial applicable boxes when completed or check NIA If not DESCRIPTIONepplicable. WA DESIGNER ENFORCE- MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-18 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ N ❑ 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ EK ❑ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ appy to exterior mass walls). ❑ R ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent 1.1 -factor. ❑ 0 ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ Q ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ b. outside air intake with damper and control, flue damper and oontrol ❑ ® ❑ 2. No oontinuous burning gas pilot lights allowed. ❑ IR ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ R ❑ § 150(g): Vapor barriers mandatory In Climate Zones 14 and 18 only. ❑ N ❑ § 150(l): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑X ❑ ❑ permeanca rate no greater than 2.0 perm/inch. § 118: Insulation specified or Installed meets Insulation installation quality standards. Indicate type and include ❑ O ❑ CF -6R Form: § 118-17: Fenestration Products, Exterior Doors, and InfiltratioNF41Uation Controla. ❑X ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and Irifiltration certification. 0 ❑ ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or 000ling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(1): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ § 1500): Water system pipe and tank insulation and 000ling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be extemaAy wrapped with Insulation ❑ 0 ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for soler systems, unfired storage tanks, or other Indirect hot water tanks have R-12 external ❑ ❑X ❑ Insulation or R-18 internal Insulation and Indicated on the exterior of the tank showing the R -value. 3. The following piping Is Insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, none eclrculeting systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be Insulated to Table 1508. 2. Coding system piping (suction, chilled water, or brine lines), piping Insulated between heating source and ❑X ❑ ❑ indirect hot water tank shall be.insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. Q ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, 0 ❑ ❑ and wind. 8. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed 51 ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑X ❑ ❑ EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. DEACON Page:8 of 11 WEST Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must Contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or initial applicable boxes when completed or check N/A If not ENFORCE - DESCRIPTION NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and retumair ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirety in conditioned space. Openings shall be sealed with mastic, tape or other dud -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than © ❑ ❑ sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ® ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (1): Cool Roof material meets specified criteriaX❑ ❑ ❑ reductions in the cross-sectional area of the duds. § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive ❑ ® ❑ dud tapes unless such tape is used in combination with mastic and draw bands. Q ❑ ❑ luminaire has factory installed HID ballast § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. § I60(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are X❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). retardant and provides shielding from solar radiation that can cause degradation of the material. © ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. 7. Flexible duds cannot have porous inner cores. ® ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ © ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. © ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ® ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btumr) § 118 (1): Cool Roof material meets specified criteriaX❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-0, Q ❑ ❑ luminaire has factory installed HID ballast § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § I60(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms be high luminaires leas than 70 ft) OR are controlled by a dimmer switch OR ❑ X❑ ❑ shall efficacy (except closets are controlled by an occupant sensor that complies with Section 'M 9(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are X❑ ❑ ❑ certified to ASTM E283 and labeled as air fight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ® ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § I50(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. © ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ® ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. DEACON Page:9 of 11 WEST Residential Kitchen Lighting Worksheet WS -5R RESIDECENCE DEACON WEST .12/18/2005 Project Title Date At least 50% of the total rated wattage of permanently Installed luminaires In kitchens must be In luminaires that are high efficacy luminaires as defined In Table 150.0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following Information for all luminaires to be Installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 1 32w ComDact Fluorescent Tri le 4 Pin Yes X No F 38.0 x 7 = 266 or W -Pow Voltage Halogen Yes I No 11X 54.0 x 3 = or 162 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes Nox or Yes No x = or Yes No x or Yes No x = or Yes No x = or Yes No x = or Yes No x or _ Yes No x or Yes No x = or Yes No x = or Yes JNo x = or Yes x = or Yes x = or Yes x = or Total A: 266 B: 162 COMPLIES IF A;-)- B YES ® NO ❑ EnergyPro 4.0 by EnergySoft User Number. 3715 Job Number. DEACON Page: 10 of 11 WEST .r IH -VAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE RESIDECENCE DEACON WEST 12/18/2005 SYSTEM NAME FLOOR AREA HVAC System 5,016 69.1 of 111.0/77.60F Outside Air 0 dm 79 1/62.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 2,758 67,509 5,966 1,958 72,918 0 6,403 5,218 0 0 0 0 0 0 0 0 0 6,403 5,218 80,314F 5,9661 83 355 YORK P1DUB16V/CZB04211 160,341 5,543 320,000 Total Adjusted System Output 160,34 5,543 320,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of Heating Coil Supply Fan 5600 cfm 105.0 of Supply Air Ducts 104.1OF ROOMS 70.0 of �% Return Air Ducts 4 79.1/62.90F M 55.0/53.70F Cooling Coil Supply Fa 5600 dm 55.0 / 53.7 of Supply Air Ducts Fan 56.1 / 54.1 of 42.2% R.H. ROOMS 78.0 / 62.5 OF h Return Air Ducts 'I L EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number. DEACON Page: 11 of 11 WEST J TITLE 24 REPORT Title 24 Report for: RESIDECENCE DEACON WEST 78401 DEACON WEST LA QUINTA, CA Project Designer: DAVID YORK, ARCHITECT #12 W. AVE. SAN GABRIEL SAN CLEMENTE, CA 92672 (949)429-5591 Report Prepared By: DAVID YORK David York, Architect 12 West Ave. San Gabriel San Clemente, CA 92672 (949) 887-8034 CITY OF LA QUANTA BUILDING & SAFETYDEPT. APPROVED FOR CONSTRUCTION Job N !EST rDEACO Date: � � 9 T T � 5/19/2006 MAY 2 4 2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliY ncye report. This program has a proval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 266.Building_Energy.E-fficiency-Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number. DEACON WEST User Number: 3715 M O TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 Form WS -5R Residential Kitchen Lighting 10 HVAC System Heating and Cooling Loads Summary 11 EnergyPro 4.0 by EnergySoft Job Number: DEACON WEST User Number: 3715 Certificate Of Compliance: Residential ft2 (Part 1 of 3) CF -1 R BE.S.I.DE.C_ENCE-DEACQN_WES1 ft2 Raised Floor Area: _ 5/1.9/_2006 Project Title 28401DEAC0-N WEST�_QU1N� Slab on Grade Area: 5,016 Date Project Address 8.0 ft Building Permit # -David-Y_ork Architect 672 _0_0.6.9. R-21 __R -_0_0__90_____q0 (949) 887-8034 Telephone Plan Check/Date Documentation Author YVall_ Wood- 9.7.8_ _0.069_ _EZ21 _3_0_0-27.0_-90 _EI_ie0 4,3.7.8_ _0.025_ _R38_ X0_0_ -_0__0 15 Field Check/Date Cornptce Method Roof Wood Climate Zone 0 Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.47 1.20 0.27 Space Cooling 56.00 48.00 7.99 Fans 8.41 7.98 0.43 Domestic Hot Water 5.12 8.21 -3.09 Pumps 0.00 0.96 -0.96 Totals 71.00 66.35 4.64 than Building Type:] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (North) 0 deg Natural Gas Area: 1,234 ft2 Avg. U: 0.43 6.5 Total Conditioned Floor Area: 5,016 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: _ 0 ft2 Slab on Grade Area: 5,016 ft2 Average Ceiling Height: 8.0 ft Number of Dwelling Units: 1.00 672 _0_0.6.9. R-21 __R -_0_0__90_____q0 Ratio: 24.6% Avg. SHGC: 0.33 Number of Stories: . 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area VAC_System5,0.1.6 40,128 4.00_ -Conditioned- -Setback- 2 _n/a OPAQUE SURFACES Insulation Act. 1stF_loor 1sLF_loor Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wood_ _229.0.0.69_ __R -_2_t X0.0_ _0_-9.0 1s.LFJoor wall -Wood- 520 _0.069 _R210=0_0 0-90 AsLF_loor 1.sLEloor 1.SLEIo.oT 1 st_Eloo.r Wall Wood_ 1.5.0 0.06.9 _R-21 _3_00_ -0--90 Door None- 24_ -0-500--Mone- R-0_0__0_____90 Wall_ Wood_ 672 _0_0.6.9. R-21 __R -_0_0__90_____q0 Wall_ Wood_9_4 _0_0.6.9_ R-21 __R_-0_0_ X8.0_-90 YVall_ Wood- 9.7.8_ _0.069_ _EZ21 _3_0_0-27.0_-90 Roof Wood- 4,3.7.8_ _0.025_ _R38_ X0_0_ -_0__0 Roof Wood_ 23.8_ 0.0.36_ _R_30. 0`0..0_ 0 0 Roof Wood 400 _0.036_ _R3.0 0'`0..0 _0 0 Gains Condition Y / N Status JA IV Reference Location / Comments New -09=A6 New _09_A6 1stF_loor 1sLF_loor New New N.ew 09_A6 28A4 0.9=A6 Ast_Soor 1.stEloor 1s.LEloor. Kew _(19A6 1s.LFJoor New New New New _0.9=A6 0_1--A18 02=A9 _02A9 AsLF_loor 1.sLEloor 1.SLEIo.oT 1 st_Eloo.r EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number. DEACON Page:3 of 11 WEST Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R RESIDECENCE DEACON WEST 5/19/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area LI -Factor' SHIS Azm. Tilt Stat. Glazing Type Comments _1- Window Eron. t_-(North)_56.0 _0--90116- _0-70 -I-t6--B 0 -90 New DoubleJmetaLClear 1.st-Eloor 2 Window Front (North) 72.0 0.350 NFRC 0_25 NFRC 0 90 New JELD-WEN FRENCH 1st Floor 3 Window Front (North) 19.2 0.310 NFRC 0_33 NFRC 0 90 New JELD-WEN FIXED 1st Floor 4 _Window Front (North) 30.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 5 Window Front (North) 9.8 0.310 NFRC 0_33 NFRC 0 90 New JELD-WEN FIXED 1st Floor 6 Window Front North) 10.0 0.350 NFRC 0_29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 7 Window Front(.North)9Z0_ 03 NFRC 0.29 NFRC 0 90_ New .QLD -WEN OPENABLE 1it Floor 8 Window Front (North) 10.0 0.350 NFRC 0.29 NFRC 0 90 New JELD-WEN OPENABLE 1st Floor 9 Window FrQnt _(Nor h) 12.Q 0�0 NFt� 0.3.3 NFRC_ 0_ 00 N_ew JELD-WEN FIXED 1St FLO-O 10, Window Front_(NOrtb) 8.0 0.310 NFRC Q33 NFRC 0 W New JELD-WEN FIXED 1st Floor 11 Window LeftEast 24.0 0.350 NFRC 0_25 NFRC 90 90 New JELD-WEN FRENCH 1st Floor 12 Window Left East 36.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor 13 Window Left (East) 14.1 -0-3J-0 -N-ERC _0_33 NFRC 90 90- New JELD-MENFIXED 1st-F_I.00r 14 Window Left (East) 22.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor 15 Window Left (East) 30.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor 16 Window Left (East) 30.0 0.350 NFRC 0_29 NFRC 90 90 New JELD-WEN OPENABLE 1st Floor 17 _Window Left (East 60.0 0.350 NFRC 0_29 NERC 90 90 New JELD-WEN OPENABLE 1st Floor 18 Window Left East 19.6 0.310 NFRC 0_33 NFRC 90 90 New JELD-WEN FIXED 1st Floor 19 Window Left_(Eas1) ---52-0 0 359 NFRC___�29 NFRC 92 a New QLD -WEN OPENABLE 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 8.0 8.0 6.0 0.1 6.0 6.0 2 Bug Screen 0.76 8.0 5.0 6.0 0.1 6.0 6.0 3 Bug Screen 0.76 3.0 5.0 6.0 0.1 6.0 6.0 0.1 4.0 0 0.1 4.0 0 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Buo Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 8.0 3.0 8.0 0.1 8.0 8.0 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 350 None No Insulation 26-A1 New 1st Floor Slab Perimeter 150 None No Insulation 26-A1 New 1st Floor Run Initiation Time: 05/19/06 07:34:13 Run Code: 1148049253 EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number. DEACON Page:4 of 11 WEST Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R RESIDECENCE DEACON WEST 5/19/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 20 -Window Left_(East) _35.0 0 3.50 -NERC. _029 -NERC _9Q _90 New JELD--WEDL02ERIBLE1sLEloor 21 Window Left East 40.0 0.350 NFRC 00=25 NFRC 90 90 New JELD-WEN FRENCH list Floor 22 Window Left East 9.8 0.310 NFRC 0_33 NFRC 90 90 New JELD-WEN FIXED 1st Floor 23 Window Rear (South) 11.2 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 24 Window Rear (South) 54.0 0.350 NFRC 0_29 NFRC 180 90 New JELD-WEN OPENABLE 1st Floor 25 Window Rear (South) 198_0 0.620 NFRC 0_40 NFRC 180 90 New FLEETWOOD DOOR 1st Floor 26 in ow Rear (mouth) 960 0620 NFRC 0� NFRC 180_ 92 New FLEETWOOD �QR 1st�or 27 Window Rear South) 9.8 0.310 NFRC 0.33 NFRC 180 90 New JELD-WEN FIXEC 1st Floor 2$ Window Rear --J!5ouLh)_30U 0350 NFRC 0 29 NFRC 180 90 New JELD-WEN OPENA LE 1st FIQor 22 wind_ w Ri ht Myst) 484 0.350 NFRC 029 NSC 270_ 90 New _JELD-W N OPENABLE 15t Floor 0Q Window Rightest) 11.5 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor 31 Window Right (West) 24.0 0.310 NFRC 0_33 NFRC 270 90 New JELD-WEN FIXED 1st Floor 32 Window Right_(YN_est)--QJ1-350NER.0 0.29 -NFRC. _2Z0_ 90 Nem J.ELDLWEN_OP-ENLiBLE__-1st-Eloor 33 Window Rioht (West) 36.0 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPERABLE 1st Floor 34 Window Right est) 10.0 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor 35 Window Right (West) 36.0 . 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor 36 Window Right (West) 11.0 0.350 NFRC 0;29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor 37 Window Righest) 30.0 0.350 NFRC 0_29 NFRC 270 90 New JELD-WEN OPENABLE 1st Floor 0-8Window Right--M-est)9� 0359 NFRC Q29 NFRC _270- 90 New JELD-WEN OPENABLE 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. [Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Buy Screen 0.76 _"-O 160 10.0 --0J 10.0 1000 1 4.0 00 1 4.0 --Q 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 05119106 07:34:13 Run Code: 1148049453 EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number. DEACON Page:5 of 11 WEST Certificate Of Compliance: Residential (Part 3. of 3) CF -1 R RESIDECENCE DEACON WEST 5/19/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated' Tank Energy Standby' Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE' (%) Ext. Rheem 41 VRP50PT Small Gas Recirc/No Control 2 40,000 50 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length U_ Add 1/2" Control # HP TVDe In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Finn: DAVID YORK, ARCHITECT Address: #12 W. AVE. SAN GABRIEL SAN CLEMENTE, CA 92672 Telephone: (949)429-5591 �— eimidd Enfdreement Name- Title/Firm: Address: Telephone: Documentation Author Name: DAVID YORK Title/Firm: David York, Architect Address: 12 West Ave. San Gabriel San Clemente, CA 92672 4.0 by Energ_ySoft User Number: 3715 Job Number. DEACON Page:6 of 11 WEST Certificate Of Compliance: Residential (addendum) CF -1 R RESIDECENCE DEACON WEST 5/19/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the Justification, and may reject a building or design that otherwise complies based on the idequacy of the special justification and documentation submitted. Plan I Field The HVAC System "HVAC System" includes credit for Reduced Fan Power. Fan is shown in the HERS section below. This house has reduced infiltration and/or mechanical ventilation. The homeowner's manual provided by the bu Ider must include operating instructions for the homeowner on how to use operable windows and/or mechanical ventilation to achieve adequate ventilatic n. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Plan Field Installation certificate. The HVAC System "HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF4R. The HVAC System "HVAC System" incorporates a HERS verified Refrigerant Charge test or a HERS verged Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System "YORK P1 DUB I6V/CZB04211" includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. This building has tight construction with reduced infiltration and a target blower door test range between 1970 and 6436 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 1970 CFM at 50 pascals, the house must either be provided with a ven`ilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number: DEACON Page:7 of 11 1 WEST Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications q for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check NIA if not ENFORCE - applicable. 1' NIA DESIGNER MENT Building Envelope Measures �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. 1:1. n ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ f§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass wails). i § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ a ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ n ❑ b. outside air intake with damper and control, flue damper and control ❑ 0 ❑ 2. No continuous burning gas pilot lights allowed. ❑ n ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements speed in the ACM Residential Manual. ❑ 0 ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ N ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor Q ❑ ❑ permeance rate no greater than 2.0 perinfinch. § 118: Insulation speed or installed meets insulation installation quality standards. Indicate type and include ❑ a ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Q ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ 0 ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ _ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and 0 ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑X ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑X ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed Q ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑X ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number,. DEACON Page:8 of 11 WEST 4Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not applicable. ENFORCE - N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh ❑ or tape shall be used. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other thanX❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ reductions in the cross-sectional area of the ducts. dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 3. Joints and seams of dud systems and their components shall not be sealed with cloth back rubber adhesive ❑ X❑ ❑ dud tapes unless such tape is used in combination with mastic and draw bands. 119(d). ❑ a ❑ 4. Exhaust fan systems have back draft or automatic dampers. EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number: DEACON 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ Q ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ X❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coaling that is water retardant and provides shielding from solar radiation that can cause degradation of the material. -i a El El 7. Flexible ducts cannot have porous inner cores.` § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outsideof the ❑ Q ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ X❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑X ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria X❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ X❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. 1 § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, X❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high luminaires less than 70 ft) OR by dimmer OR ❑ X❑ ❑ efficacy (except closets are controlled a switch are controlled by an occupant sensor that complies with Section 1) 9(d) that does not tum on automatically or have an always on option. 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑X ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the FAI ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑X ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number: DEACON Page:9 of 11 WEST Residential Kitchen Lighting Worksheet WS -5R RESIDECENCE DEACON WEST 5/19/2006 Project Title Date At least 50% of the total rated wattage of permanently Installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Wafts Other Wafts 1 32w Compact Fluorescent Triple 4 Pin Yes X1 No F 38.0 x 7 = 266 or MWPow Voltage Halogen Yes No I X 54.0 x 3 = or 162 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or, Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x - or Yes No x = or Yes No x = or Total A: 266 B: 162 COMPLIES IF A z B YES Q NO ❑ EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number. DEACON Page: 10 of 11 WEST IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE RESIDECENCE DEACON WEST 5/19/2006 SYSTEM NAME FLOOR AREA HVAC System 5,016 mr.iNFFRINr. CHFCKS SYSTEM LOAD Number of Systems 4 Heating System Output per System 80,000 Total Output (Btuh) 320,000 Output (Stuh/sgft) 63.8 Cooling System Output per System 48,000 Total Output (Stuh) 192,000 Total Output (Tons) 16.0 Total Output (Btuh/sgft) 38.3 Total Output (sgft/Ton) 313.5 Air System CFM per System 1,400 Airflow (cfm) 5,600 Airflow (cfm/sgft) 1.12 Airflow (cfm/Ton) 350.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF Outside Air — 0 0 cfm 69.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFM Sensible Latent CFM Sensible 2,773 67,885 5,966 1,961 73,06 0 6,439 5,228 0 0 0 0 0 0 0 0 0 6,439 5,228 80 762 5 966 83,517 YORK P1 DUB 1 6V/CZBO4211 160,362 5,526 320,000 Total Adjusted System Output 160,362 5,526 320,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.10F . 105.OoF Heating Coil Supply Fan 5600 cfm 105.0 of —� Supply Air Ducts 104.1OF ROOMS 70.0 of Return Air Ducts TOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 11.0/77.60F 79.1 / 62.9 of 55.0 / 53.7 of 55.0 / 53.7 of Q Supply Air Ducts Obtside Air 0 cfm Cooling Coil Supply Fan 56.1 / 54.1 of 5600 cfm 42.2% R.H. I ROOMS 79.1/62.9 of 78.0 162.5 of Return Air Ducts I EnergyPro 4.0 by EnergySoft User Number: 3715 Job Number: DEACON Page: 11 of 11 WEST