Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1674 (SFD) Title 24
ui •Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11212112013 Date Project Address Lot 3, Traditions La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,419 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,419 Radiant Barrier New Wall Wood Framed R-21 3,919 New Slab Unheated Slab -on -Grade None 4,419 Perim Wd013A3a A-LiN New 1NIf1 v-130 FENESTRATION U. We - - Orientation Area(ft). Factor SHGC Overhang Sidefins Shades Status Rear (S) 170.0 0.390 0.36 none none Bug Screen New s Right (1/10 201.6 -0.390 *,,,,0.36 -„,none.. ,.—,nnone I.,,','.'Bug,Screenpw4k,_ New Front (N) - � 37.5 1,1. '., 4390 V 0.36 , none'V .none _ Bug Screee'n, New LeftE ;'` 103.8 () 0.390 0.36 . ;none r one`� Bug �Screens - . q New Front (N)'t” j71'3 0. 950 0!149" none_ 1 ,.; - \ none _j,".4 Bug Screen\_` ' . " ° ,New 0.O� ,s 0390„(S) . ne,,,.`+ Bug, 4Screener 'tPJJt& 4New Right (VV) 72.0 ( ' 0.390 0.36 8.0 - none Bug Screen New Left (E)__•,... � , 32.5 0.390 0.36 2.0 2.012.0 Bug Screen New i HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.50 HSPF Split Heat Pump 14.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vente ,----_, 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented'' Y n ----New WATER HEATING Qty. Type 011\rG & S � J Gallons Min. Eff Distribution �,,�t ),, AFE7V Put t"u 2 Small Gas 50 0.62 All Pipes Ins f-OR- I11DUCT 8 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2013-12-21T13:41:34 /D: Pae 1 of 7 Reg: 213-NO09556BA-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: Ca10ER� T�nc 'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11212112013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 709.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 275.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 338.0 ft2 Covered Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 147.0 ft2 Exposed Slab Floor, 3.500" thick at Casita The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 224.0 ft2 Covered Slab Floor, 3.500" thick at Living/Dining/Kit/Entry HIGH MASS Design - Verify Thermal Mass: 2,170.0 ft' Exposed Slab Floor, 3.500" thick at Living/Dining/Kit/Entry The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 420.0 ft2 Covered Slab Floor, 3.500" thick at Bedrooms 2, 3 & 4 HIGH MASS Design - Verify Thermal Mass: 136.0 ft2 Exposed Slab Floor, 3.500" thick at Bedrooms 2, 3 & 4 The Roof R-38 Roof(R 38.2x 14.16) includes crediffor a'Radiant-Barfier, that is -Continuous meeting eligibility -and installation criteria as specified in t� .%ice V A Residen�t'ial _p Iendix , 4.22..�ry [7 f f HER REQUIRED VERIFICATION - Items in thisection require field testing and/or verifidation by a certified HERS-Rater.-Thelinspector,must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 25ANB7601F4BNF006 includes credit fora 12.0 EER Condenser. A certified HERS rater must field verify the installation of the'correct Condenser r The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria.' The Cooling System Carrier 24ANB748158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB736158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. BUIL F I A j> N, ._ DEP R CDNSTRV CD LATE Ene Pro 5.1 by EnerqySoft User Number: 6712 Run Code: 2013-12-21T13:41: D: Page 2 of 7 Reg: 213-N0095568A-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: Cal RTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type 12 Single Family ❑ Addition Alone Date Custom Residence I ❑ Multi Family ❑ Existing+ Addition/Alteration 1121211201i ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.16 3.60 0.55 Space Cooling 53.84 46.73 7.12 Fans 10.64 13.15 -2.51 Domestic Hot Water 8.25 9.51 -1.26 Pumps 0.00 0.00 0.00 Totals 76.90 73.00 3.90 Percent Better Than Standard: 5.1 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 741 109 Fuel Available at Site: Natural Gas (E) 1,706 136 Raised Floor Area: 0 (S) 912 350 Slab on Grade Area: 4,419 M9 1,429 274 Average Ceiling Height: 11.3 Roof 4,419 0 Fenestration Average U -Factor: 0.44 TOTAL: 869 Average SHGC: 0.37 Fenestration/CFA Ratio: 19.7 REMARKS r STATEMENT`OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts' 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 12!21!2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and re oc gniies-that.compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation�qualifyl anduiIdin�gAn e� sealing require f installer testing and certification and field verification by an approved 14ERa[rater� & S h� NTA AFEiy DEP Designer or Owner (per Business & Professions Code) APS T. FO.PCO S VED Company Helton, DeFord & Associates Address 17411 Irvine Blvd., Suite 0 Name Jim Deford CTION City/State/Zip Tustin, CA 92780 Phone (909) 957-455IDATE d License Date �_----� Ene Pro 5.1 by EnemySoft User Number: 6712 Run Code: 2013-12-21 T13:41:34 ID: Page 3 of 7 Reg: 213-NO09556BA-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: CalCERTS, Inc 'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12/21/201 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 984 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Wall 30 0.069 R-21 0 90 New 4.3.1-A6 Master Suite Wall 260 0.069 R-21 90 90 New 4.3.1-A6 Master Suite Wall 100 0.069 R-21 180 90 New 4.3.1-A6 Master Suite Wall 564 0.069 R-21 270 90 New 4.3.1-A6 Master Suite Slab 709 0.730 None 0 180 New 4.4.7-A 1 Master Suite Slab 275 0.730 None 0 180 New 4.4.7-A 1 Master Suite Roof 485 0.026 R-38 270 0 New 4.2.1-A9 Casita Wall 140 0.069 R-21 0 90 New 4.3.1-A6 Casita Wall 270 0.069 R-21 90 90 New 4.3.1-A6 Casita Wall 80 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 300 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 338 0.730 None 0 180 New 4.4.7-A1 Casita Slab 147 0.730 None 0 180 New 4.4.7-A1 Casita Roof 2,394 0.026 R-38 270 0 New 14.2.1-A9 Living/Dining/Kit/Entry Wall 262 0.069,R-21 0 90 New 14.3.1-A6 Livingli)ininglKitlEntry FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 80.0 0.390 NFRC 0.36 NFRC 180 New Double non-metal tinted Master Suite 2 Window 18.8 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 3 Window 12.5 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 4 Window 4.9 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 5 Window - 12.5 0.390 NFRC 0.36 NFRC _ _ 270 New-_.,, Double non-metal tinted - Master Suite 6 Window:- 'N/4.9 0.390 NFRC .,i V 0.36 NFRC: -270 New f Double non-metal tinted / _Master Suite 7 Window . 6.0 0.390 NFRC / 0.36 'NFRC 270 New • Double non-metal tinted -- " Master Suite 8 Window 18.0 0.390, NFRC ` 0.36 NFRC ,.4270 New.'.:/r`' Double non-metal tinted. ',V Master Suite' 9 Window 1,8,:0 1.0.390 NFRC r 0.36 NFRC V 270 New ,J ► Double non-metal tinted 3, .'s. Master,Suite .�,. 10 Window 4 /12.5; ;y- 0.390, NFRC . ' 0.36 NFRC 0 0 New.. -1 Double non-metal tinted i Casita:;t J&, 11 WindowoK 102.5-NFRC+' -0:36 NFRC : �r .x0 New - Double non-metal tinted , 1 Casita C l`�'� 12 Window 6.0 0.390 NFRC " 0.36 NFRC 90 New Double non-metal tinted "- Casita 13 VVYndow _ 10.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 14.. Window 110.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 15 Window 24.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 16 Window 10.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Casita (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt REA Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Bu Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 E Mr_ q 1 A f 13 Bug Screen 0.76 M A r..-_ ` `-'tA►-i _ t 7NEC)-, 14 Bug Screen 0.76 t t 2 W n 1 " ' 15 1Bug Screen 1 0.76 M t -Q) (�nr, - �`LV 16 JBug Screen 0.76 " r L7 DATE RX I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-12-21T13:41:34 Pe e 4 of 7 Reg: 213-NO09556BA-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: CalCERTS, Inc 'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/21/201 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 728 0.069 R-21 90 90 New 4.3.1-A6 LivinglDiningXttlEntry Wall 352 0.069 R-21 180 90 New 4.3.1-A6 LivingvDininglKitlEntry Wall 152 0.069 R-21 270 90 New 4.3.1-A6 LivinglDininglKitlEntry Slab 224 0.730 None 0 180 New 4.4.7-A1 LivinglDiningXitlEntty Slab 2,170 0.730 None 0 180 New 4.4.7-A1 LivinglDininglKitlEntry Roof 556 0.026 R-38 270 0 New 4.2.1-A9 Bedrooms 2, 3 & 4 Wall 200 0.069 R-21 0 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Wall 312 0.069 R-21 90 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Wall 30 0.069 R-21 180 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Wall 139 0.069 R-21 270 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Slab 420 0.730 None 0 180 New 4.4.7-A1 Bedrooms 2, 3 & 4 Slab 136 0.730 None 0 180 New 4.4.7-A1 Bedrooms 2, 3 & 4 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 10.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Casita 18 Window 12.5 0.390 NFRC 0.36 NFRC 0 New Double non-metal tinted Living/Dining/KitlEntry 19 Window 71.3 0.950 NFRC 0.49 NFRC 0 New Entry Door Living/Dining/KitlEntry 20 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 21 Window_ 1.3 0.390 NFRC . 0.36 NFRC 90 New Double non-metal tinted ,,. Living/Dining/Kit/Entry 22 Window: 'V"1.3 0.390 NFRC 0.36 NFRC w 190 New: f '1 Double non-metal tinted Y . L "Living/Dining/Kit>Entry 23 Window i 1.3 0.390 NFRC: 1 0.36 NFRC 90 New ; Double non-metal tinted +.. _ " Living/Dining/Kit/Entry 24 Window 1.3- "0.390. NFRC "' 0.36 NFRC' :.+t 90 New: « o- Double non-metal tinted,- Living/Dining/KVEntry 25 Window ,.f!3 J 0.390 NFRC , ' 0.36 NFRC t+ 90 New ti l Double non-metal tinted _N Living/Dining/Kit(Entry% 26 Window 4 )90.0, i 0.390 NFRC 0.36 NFRC,.' ;180 'New. 4 Double non-metal tinted A Living/Dining/Kit/Entry' 27 Window, t 1180:0 x.0:390 NFRC; ^.x0.36 NFRC _'z :C_t180 New 'a: Double non-metal tinted,,0ge"" Living/DininglKlt/Entry 28 Window 24.0 '0.390 NFRC 0.36 NFRC 270 New _ Double non-metal tinted Living/Dining/KiUEntry 29 Window _ 48.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Living/Dining/Kit/Entry 30 Window '25.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 31 Window 7.5 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 32 Window 8.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 _ 24 Bug Screen 0.76 25 Btkq Screen 0.76 N t I( i` ( I M I T A 26 Bug Screen 0.76 1 F I III fow 27 Bug Screen 0.76 10.0 18.0 14.0 0.1 14.0 114.0 - 28 Bug Screen 0.76 8.0 3.0 8.0 0.1 8.0 18.0 PI if-v):(j),%{f I 29 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 18.0 F A. 30 Bu Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 0.1 2.0 ' 0 x'0.9 I 2.0 0 31 Bu Screen 0.76 1.5 5.0 2.0 0.1 2.0 2.0 0.1 2.0 0 0.1 2.0 0 32 [Bug Screen 0.76 DA FE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-12-21 T13.41:34 ID: Page 5 of 7 Reg: 213-NO09556BA-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/21/201 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor CavitYTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 33 Window 8.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 34 Window 30.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 35 Window 20.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Bedrooms 2, 3 & 4 36 Window 40.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Bedrooms 2, 3 & 4 37 Window— 20.0 0.390 NFRC 0.36 NFRC 270 New. Double non-metal tinted _., Bedrooms 2, 3 & 4 38 Window" 'V6.0 0.390 NFRC „r f 0.36 NFRC♦ 270 New ' * Double non-metal tinted ( � . Bedrooms 2, 3 & 4 4�ti7 �i, krt 1 l `_ 3 fi• + X11•"r��'j�%�t�; �t /� '�4- ,i, + � � . v'f�a. 'i 1« :.�,��✓ '.., •i x'i, � f' wM., ':Y• ' 4 �Y�" { aL-.t iLs� i .� 'IGF Fr'` (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len I H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 r A .-N F F,, N ILMINvG ' SA FTY nEPT_N ki I f I _l N FCR C 'Ja 7NI N N N N Df ATE _ BY- EnergyPro 5. 1 by EnergySoft User Number: 6712 RunCode: 2013-12-21713:41:34 ID: Page 6 of 7 Reg: 213-NO09556BA-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: CalCERTS, Inc 'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 12/21/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 12/21/2013 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Custom Residence Building Type 121 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+Addition/Alteration Date 12/21/201 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC 1 Master Suite 984 10,9221 Casita 485 4,850 HVAC 2 & 3 Living/Dining/Kit/Entry 2,394 28,728 HVAC 4 Bedrooms 2, 3 & 4 556 5,560 Totals 4,4191 01 01 0 HVAC SYSTEMS System Name Qty.' Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 i. Split Heat Pump 8.50 HSPF Split Heat Pump 14.5 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC 4 1 —Central—Furnace-42,80% AFUE Split Air.Conditiond-o"M ^14.5 SEER,. Setback New HVAC DISTRIBUTION f if � i- �' � 14 _J - -1 � -_ " x ,� �`. �►,zF:'y«.��1 �;� V Ducts ""* System Name I Heitinig Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2'& 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White 50 Gal. 2 Small Gas All Pipes Ins 40,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRO;NIC.HEATING=SY-STELII-PIPING Control Hot Water Piping Length o �� -o cAPPPPipe Q — d Y GUILE?ENG S stem Nam LA & SAFE: �7FPip�e Le th � f r c��. V1 DEP' 4iarneter MuI. flIn Thick. Qty. HP Plenum Outside Buried ION EnergyPro 5. 1 by EnergySoft User Number: 6712 Run Code: 2013-12-21713:41:34 ID: Page 7 of 7 Reg: 213-NO09556SA-000000000-0000 Registration Date/Time: 2013/12/21 17:08:34 HERS Provider: CalCERTS, Inc 9 f BUILDING ENERGY ANALYSIS REPORT PROJECT: Custom Residence Lot 3, Traditions La Quinta, CA 92253 Project Designer: Helton,. DeFord & Associates 17411 Irvine Blvd., Suite O Tustin, CA 92780 (909) 957-4550 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 E""EIVED DEC 3 0 2013 Yl C®,MurYr� DEVELOPMENT �. LA QUINTA Job Number: PMENT Date: 12/21 /2013 7/—, O� C 4 S� F 1Qt Jr1 jV The EnergyPro computer program has been used to perform the calculations summarized in this com e repbrtm7h s rogF C has x� is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2v8�Build�t)g/unrrVU.c�ency StandardThis program developed by EnergySoft, LLC—wwwf�'CT1oN EnemvPro 5.1 by EnemvSoft User Number: 6712 RunCode: 2013-12-21713:41:34 ID® C • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11212112013 Date Project Address Lot 3, Traditions La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,419 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,419 Radiant Barrier New Wall Wood Framed R-21 3,919 New Slab Unheated Slab -on -Grade None 4,419 Perim = 429' New FENESTRATION Orientation Area(ft) U- Exterior Factor SHGC Overhang Sidefins Shades Status Rear (S) 170.0 0.390 0.36 none none Bug Screen New Right (W) 201.6 0.390 0.36 none none Bug Screen New Front (N) 37.5 0.390 0.36 none none Bug Screen New Left (E) 103.8 0.390 0.36 none none Bug Screen New Front (N) 71.3 0.950 0.49 none none Bug Screen New Rear (S) 180.0 0.390 0.36 14.0 none Bug Screen New Right (M 72.0 0.390 0.36 8.0 none Bug Screen New Left (E) 32.5 0.390 0.36 2.0 2.02.0 Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.50 HSPF Split Heat Pump 14.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling 1ns,pentedei�----� 8.0 New WATER HEATING Qty. Type BUq r)f " LA�---� Gallons Min. Eff DistributrCo:n a & .c„ �U�''� TStatus 2 Small Gas 50 0.62 All Pipes /nss , y''3 `` , „r tJEP]`New I rUr� CON.c p—TMJ , "- %" ION h EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2013-12-21T13:41:34 ID_* " tPa e 3 of 27 C • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Custom Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11212112013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 709.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 275.0 ft' Exposed Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 338.0 ft' Covered Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 147.0 ft2 Exposed Slab Floor, 3.500" thick at Casita The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 224.0 ft2 Covered Slab Floor, 3.500" thick at Living/Dining/Kit/Entry HIGH MASS Design - Verify Thermal Mass: 2,170.0 ftZ Exposed Slab Floor, 3.500" thick at Living/Dining/Kit/Entry The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 420.0 ft2 Covered Slab Floor, 3.500" thick at Bedrooms 2, 3 & 4 HIGH MASS Design - Verify Thermal Mass: 136.0 ft2 Exposed Slab Floor, 3.500" thick at Bedrooms 2, 3 & 4 The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 25ANB760/F4BNF006 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB748158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB736158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. C CrrY n iz ---�_ O'"�� C''TION EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-12-21 T11.41 SID: a e 4 of 27 1� 0 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Custom Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 12/21/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.16 3.60 0.55 Space Cooling 53.84 46.73 7.12 Fans 10.64 13.15 -2.51 Domestic Hot Water 8.25 9.51 -1.26 Pumps 0.00 0.00 0.00 Totals 76.90 73.00 3.90 Percent Better Than Standard: 5.1 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 741 109 Fuel Available at Site: Natural Gas (E) 1,706 136 Raised Floor Area: 0 (S) 912 350 Slab on Grade Area: 4,419 M9 1,429 274 Average Ceiling Height: 11.3 Roof 4,419 0 Fenestration Average U -Factor: 0.44 TOTAL: 869 Average SHGC: 0.37 Fenestration/CFA Ratio: 19.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 12212013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater: Owner Business Professions Code) Designer or (per & I BU�� �1� Company Helton, DeFord 8 Associates ` G& �• , r V �q Address 17411 Irvine Blvd., Suite 0 Name Jim Deford 6 _ �: ' �--, DE -# Date City/State/Zip Tustin, CA 92780 Phone (909) 957-4550 �dpNSTRV ,in oar EnergyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-12-21T13.4r.'ID: BY Pa e 5 of 27 r__4 L i CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition Alteration Date 11212112013 OPAQUE SURFACE DETAILS Surface Area U- Insulation Joint Appendix Factor Cavitv Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments -Type Roof 984 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Wall 30 0.069 R-21 0 90 New 4.3.1-A6 Master Suite Wall 260 0.069 R-21 90 90 New 4.3.1-A6 Master Suite Wall 100 0.069 R-21 180 90 New 4.3.1-A6 Master Suite Wall 564 0.069 R-21 270 90 New 4.3.1-A6 Master Suite Slab 709 0.730 None 0 180 New 4.4.7-A1 Master Suite Slab 275 0.730 None 0 180 New 4.4.7-A1 Master Suite Roof 485 0.026 R-38 270 0 New 4.2.1-A9 Casita Wall 140 0.069 R-21 0 90 New 4.3.1-A6 Casita Wall 270 0.069 R-21 90 90 New 4.3.1-A6 Casita Wall 801 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 300 0.069 R-21 270 90 New 4.3.1-A6 Casita Slab 338 0.730 None 0 180 New 4.4.7-A1 Casita Slab 147 0.730 None 0 180 New 4.4.7-A1 Casita Roof 2,394 0.026 R-38 270 0 New 14.2.1-A9 JLivinglDininglKitlEntry Wall 262 0,069,R-21 01 90 1 New 14.3.1-A6 JLivinglDininglKitlEnlry FENESTRATION SURFACE DETAILS ID I Tvpe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 80.0 0.390 NFRC 0.36 NFRC 180 New Double non-metal tinted Master Suite 2 Window 18.8 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 3 Window 12.5 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 4 Window 4.9 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 5 Window 12.5 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 6 Window 4.9 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 7 Window 6.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 8 Window 18.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 9 Window 18.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Master Suite 10 Window 12.5 0.390 NFRC 0.36 NFRC 0 New Double non-metal tinted Casita 11 Window 12.5 0.390 NFRC 0.36 NFRC 0 New Double non-metal tinted Casita 12 Window 6.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 13 Window 10.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 14 Window 10.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 15 Window 24.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Casita 16 Window 10.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Casita (1) 1.1 -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hanq Left Fin Len H t LEA RExt Dist Len Ri ht Fin Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 _ 11 Bug Screen 0.76 12 Bug Screen 0.76 " ' 11\1T 13 Bug Screen 0.76 U I 14 Bug Screen 0.76 15 JBug Screen 1 0.76 ] li` ra lM-- 16 IBug Screen 1 0.761 1f 1R C C r• J Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2013-12-21T13:41:3 1D7-- Pae - of 27 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/21/201 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 728 0.069 R-21 90 90 New 4.3.1-A6 LivinglDiningll%lEntry Wall 352 0.069 R-21 180 90 New 4.3.1-A6 LivinglDininglKitlEntry Wall 152 0.069 R-21 270 90 New 4.3.1-A6 LivinglDininglKitlEntry Slab 224 0.730 None 0 180 New 4.4.7-A1 LivingvDininglKitlEntry Slab 2,170 0.730 None 0 180 New 4.4.7-A1 LivingvDininglKitlEntry Roof 556 0.026 R-38 270 0 New 4.2.1-A9 Bedrooms 2, 3 & 4 Wall 200 0.069 R-21 0 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Wall 312 0.069 R-21 90 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Wall 30 0.069 R-21 180 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Wall 139 0.069 R-21 270 90 New 4.3.1-A6 Bedrooms 2, 3 & 4 Slab 420 0.730 None 0 180 New 4.4.7-A1 Bedrooms 2, 3 & 4 Slab 136 0.730 None 0 180 New 4.4"7-A1 Bedrooms 2, 3 & 4 FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 10.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Casita 18 Window 12.5 0.390 NFRC 0.36 NFRC 0 New Double non-metal tinted Living/Dining/Kit/Entry 19 Window 71.3 0.950 NFRC 0.49 NFRC 0 New Entry Door LivinglDininglKitlEntry 20 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 21 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 22 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 23 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 24 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 25 Window 1.3 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Living/Dining/Kit/Entry 26 Window 90.0 0.390 NFRC 0.36 NFRC 180 New Double non-metal tinted Living/Dining/Kit/Entry 27 Window 180.0 0.390 NFRC 0.36 NFRC 180 New Double non-metal tinted Living/Dining/Kit/Entry 28 Window 24.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Living/Dining/Kit/Entry 29 Window 48.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted LivingvDininglKit)Entry 30 Window 25.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 31 Window 7.5 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 32 Window 8.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 10.0 18.0 14.0 0.1 14.0 10.0 28 Bug Screen 0.76 8.0 3.0 8.0 0.1 8.0 .0 29 30 Bug Screen 1Bug Screen 0.76 0.76 8.0 6.0 8.0 0.1 5.0 5.0 2.0 0.1 8.018-a U11 111A:" 2.0 2.0 0. P?0 TA .0 0 31 JBug Screen 0.76 1.5 5.0 2.0 0.1 2.0 12.0 0.1 Q 0 32 JBug Screen 0.76 i RUCii0N EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2013-12-21 T13- :34 Pac 7 of 27 17, CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Custom Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/21/201 OPAQUE SURFACE DETAILS Surface U- T e Area Factor Insulation Joint Appendix cavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 33 Window 8.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 34 Window 30.0 0.390 NFRC 0.36 NFRC 90 New Double non-metal tinted Bedrooms 2, 3 & 4 35 Window 20.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Bedrooms 2, 3 & 4 36 Window 40.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Bedrooms 2, 3 & 4 37 Window 20.0 0.390 NFRC 0.36 NFRC 2701 New Double non-metal tinted Bedrooms 2, 3 & 4 38 Window 6.0 0.390 NFRC 0.36 NFRC 270 New Double non-metal tinted Bedrooms 2, 3 & 4 (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 I — I f;l l_v 1V= 1 V 17T- fn, r r 77) N V i_� "` a- 0-11 I H 0- ` YI ONI DAT EnerqyRro5.1b EnergySoft User Number: 6712 _ Run Code: 2013-12-21T13:41:34 ----Pa e -8-o 27 17, CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Custom Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11212112013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC 1 Master Suite 984 10,922 Casita 485 4,850 HVAC 2 & 3 Living/Dining/Kit/Entry 2,394 28,728 HVAC 4 Bedrooms 2, 3 & 4 556 5,560 Totals 4,419 01 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Split Heat Pump 8.50 HSPF Split Heat Pump 14.5 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE S lit Air Conditioner 14.5 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 D New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White 50 Gal. 2 Small Gas All Pipes Ins 40,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 o n c a — _ I Y S stem,�NOn'enIN,, ' Pipe_Fipel- Len th rDiaMeter_,. �Ln�suy. ,chic . Qty. HP Plenum Outside Buried 01 1 01 1 Fury C DNSTRIJ 1 ❑ ! AT bY EnergyPro 5.1 by EnefgySoft User Number: 6712 Run Code: 2013-12-21 T13:41:34 ID: o� 27 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name ustom Residence Date 11212112013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. 5150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinci sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(1)3A: Insulation is protected from damage, including that due to sunlight, moisture` a ui ment,-maintenancep, and•wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a&dr retardant dr -is 6nbbsed`eritirely in conditioned space. I �0ILDING & SAFETY DEPT, 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and -Certification ,C,or'I oral on. FOR CONSTRUCTION d EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2013-12-21T13A1.-,34_ ID: P ge 10 of 27 LL", — .r- 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date ustom Residence 11212112013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more illuminated cabinet. e than.20 watts of pow r per`linear`foot-o N U1 1 Y �_ 01JINT A BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2013-12-21 T13:41:34 /D: Pag 11 of 27 IL)m i t BY I 4 r t� MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ustom Residence 11212112013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housinq and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY CF LA QUINTA. BUILDING & SKFEiY DEPT. FOR CONSTRUCTION haTc EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2013-12-21TM41:34I /4�___ Page f2 of 27 w 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ustom Residence Date 12/21/2013 System Name HVAC 1 Floor Area 1,469 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,002 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 58,000 18,998 2,277 1,274 22,002 Total Output Btuh 58,000 o Output Btuh/s ft 39.5 1,097 841 Cooling System 01 0 Output perSystem 58,000 0 0 0 0 Total Output Btuh 58,000 0 2,277 0 Total Output ons 4.8 1,097 841 Total Output Btuh/s ft 39.5 Total Output s ft/Ton 303.9 1 21,192 23,684 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Carrier 25ANB760/F4BNF006 40,130 6,534 36,225 Airflow cfm/s ft 1.36 Airflow cfm/Ton) 413.8 36,225 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 40,130 6,534 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF Heating Coil Supply Fan 88 OF 2,000 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71 / 59 °F 71/59°F 52/51°F 52/51°F c _ _ 52 / 51 OF 2,000 cfm r Cooling Coil Supply Fan FIL 3 0 & �` �� 0 l58°ED r UK �6ci RUCTION 1 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-12-21T13:41:34 UA/6-- --__BY Page 13 of 27 r 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ustom Residence Date 12/21/2013 System Name HVAC 2 & 3 Floor Area 2,394 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total ROOM Loads 1,019 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 23,062 3,260 672 29,205 Total Output Btuh 142,000 0 Output Btuh/s ft 59.3 1,331 1,435 Cooling System 0 0 Output perSystem 49,000 0 01 0 0 Total Output Btuh 98,000 0 3,260 0 Total Output Tons 8.2 1,331 1,435 Total Output Btuh/s ft 40.9 Total Output s ft/Ton 293.1 1 25,724 32,076 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 24ANB748/58CVX090 75,082 1,689 142,000 Airflow cfm/s ft 1.34 Airflow cfmiTon 391.8 Outside Air % 0.0% Total Adjusted System Output 75,082 1,689 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 142,000 F Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air-4 0 cfm 72 OF 72 OF 113 OF 113 OF /—� - -- Pi (/� Heating Coil Supply Fan o 3,200 cfm 113 F ROOM 72 OF 4 A COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 70/57°F 48/47°F 48/47°F C-- Outside c Outside AirAr 3,200 cfm ( �F LA QUO 3 & EER.09M 0 cfm Cooling Coil Supply Fan FFOR 70 / 57 OF P R E 70 / 57 OF C .qT f jr- i^k DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-12-21T13:41:34 -----Page-14 ,f 27 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ustom Residence Date 12/21/2013 System Name HVAC 4 Floor Area 556 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 507 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 51,000 10,384 911 235 9,803 Total Output Btuh 51,000 0 Output Btuh/s ft 91.7 599 482 Cooling System 0 0 Output per System 35,500 0 0 0 0 Total Output Btuh 35,500 0 911 0 Total Output ons 3.0 599 482 Total Output Btuh/s ft 63.8 Total Output s ftfTon 187.9 1 11,583 10,767 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB736/58CVX070 25,780 2,403 51,000 Airflow cfm/s ft 2.16 51,000 Jan 1 AM Airflow cfmfTon 405.6 Outside Air °f, 0.0% Total Adjusted System Output 25,780 2,403 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P M Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 112 OF 112 OF f Heating Coil Supply Fan 111 OF 1,200 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm / 58 °F_, 70/58°F 50/49°F 50/49°F c Cooling Coil Supply Fan 51 / 49 OF 1,200 cfm F.ULDis 77,1Y4 f`O Of RQ©� ,?o70 P H (W E D70 / �58 F rvri UUlNj I HUC ION EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2013-12-21T13.41:34 "� !D�— BY Page 15 of 27 • C � ROOM LOAD SUMMARY Project Name Custom Residence Date 12/21/2013 System Name HVAC 4 Floor Area 556 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Bedrooms Z 3 & 4 Bedrooms 2, 3 & 4 1 507 10,384 911 507 10,384 911 235 9,803 r-1 TV • A I'% 1MP. _ Y — -1-.1 U h I ! fl )�V ' Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL • t 507 JA 110,, 8AHC,9P!, 7F F2451 9, 03 507 v'�6,484 4STs1v CT1Vo! 9,P03 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-12-2V PV Pae 18 of 27 ROOM HEATING PEAK LOADS Project Name712/21/2013 Custom Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 984.0 ftZ Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X BUILDING AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof(R.38.2x14.16) 984.0 0.0260 46 1,177 R-21 Wall (W.19.2x6.16) 954.4 0.0690 46 3,029 Double non-metal tinted 175.6 0.3900 46 3,150 Slab -On -Grade perim = 105.0 0.7300 46 3,526 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 984 X Area another room 11.10 X &_286.,-,1_60 Height ACH`� Page Total ]=X- I i YLAT r _ & SAFET 10,882 46_=.=, 2,552 Qi 1rNTA '( DEPT TOTAL HOURLY HEAT LOSS FOR ROOM 13434 FGFT COIVSTRUCT ION Energ Pro 5.1 by Energ Soft User Number., 6712 RunCode: 2013-12-21 T13:41:34 ID: Page 19 of 27, All ROOM HEATING PEAK LOADS Project Name Custom Residence Date 12/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 485.0 ft' Indoor Dry Bulb Temperature 72'F1 Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 485.0 0.0260 46 580 R-21 Wall (W. 19.2x6.16) 790.0 0.0690 46 2,507 Double non-metal tinted 95.0 0.3900 46 1,704 Slab -On -Grade pen .m = 75.0 0.7300 46 2,519 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 485 X Area another room 10.00 X 0.318 Height ACH Page Total /60] X AT 7,310 = 1,258 TOTAL HOURLY HEAT LOSS FOR ROOM 8,568 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-12-21T13:41:34 /D: Page 20 of 27 C. CI I ROOM HEATING PEAK LOADS Project Name71212112013 Custom Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Floor Area 2,394.0 ftZ Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X BUILDING AT 'F Btu/hr = 2,863 = 4,743 = 6,500 = 3,116 = 5,776 = = = = = = = = = = = = = = = = = 22,998 46 = 6,208 (:)U -'NTA FI=TS /-,-� R-38 Roof(R.38.2x14.16) 2,394.0 X 0.0260 46 R-21 Wall (W.19.2x6.16) 1,494.4 X X 0.0690 46 Double non-metal tinted 362.3 0.3900 46 Entry Door 71.3 X , X 0.9500 46 Slab -On -Grade perim = 172.0 0.7300 46 X X X X X X X X X X X X X X X X X X X X X X X X X X I I= I Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,394 X Area to another room 12.00 X h0:265:—/ Ceiling Height ACH Page Total -60-]—X- _ [ �`�o AT ° r OF LIA & S TOTAL HOURLY HEAT LOSS FOR ROOM20, FOR STRUCTIONi Energ Pro 5.1 by Energ Soft User Number. 6712 Run Code: 2013-12-21713:41:34 I ID: Page 21 of 47 darE -_ BY ROOM HEATING PEAK LOADS Project Name712/21/2013 Custom Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Bedrooms 2, 3 & 4 Floor Area 556.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X BUILDING AT *F = = = = = = = Btu/hr R-38 Roof(R.38.2x14.16) 556.0 0.0260 46 665 R-21 Wall (W. 19.2x6.16) 680.5 0.0690 46 2,160 Double non-metal tinted 164.5 0.3900 46 2,951 Slab -On -Grade perim = 77.0 0.7300 46 2,586 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 556 X Area another room r—� 10.00 X0.31,8 Height ACH Page Total ;1/;6p �� fX' 'T & SAFETY A � rr, R , —_ 8,362 4& ��T/� DEP TOTAL HOURLY HEAT LOSS FOR ROOM ° b� rJ 9 80 V" [-J UUNSTRUCTIpN Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-12-21713:41:34 I p �- Page 22 of -7 � BY r� RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 12/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 984.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranqe: 34 OF Opaque Surfaces R-38 Roof(R.38.2114.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 984.0 0.0260 56.0 30.0 0.0690 23.0 260.0 0.0690 33.0 100.0 0.0690 26.0 564.4 0.0690 33.0 21.2 4.9 42.5 0.0 21.2 12.5 42.5 0.0 21.2 4.9 42.5 0.0 21.2 6.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Internal Gain Orientation Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = _ = = = 0.0 21.2 80.0 21.2 0.0 21.2 18.8 42.5 0.0 21.2 12.5 42.5 0.0 21.2 4.9 42.5 0.0 21.2 12.5 42.5 0.0 21.2 4.9 42.5 0.0 21.2 6.0 42.5 0.0 21.2 18.0 42.5 0.0 21.2 18.0 42.5 Page Total 1.0 Occupants X 230 Btuh/occ. _ 0.0 Dwelling Unit X 1 1,600 Btu = Infiltration: 1.064 X 0.94 X 53.84 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 10 Occupants X T-200° -Btu h/ooccc.,,®_ _ UI1-Y OF - Infiltration: 4,771 X 0.94 X 53.84 X 0.00523 = GQUI BE11Lp�{� Air Sensible CFM ELA AW & SAFETY L • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM UFS Btu/hr 1,433 48 592 179 1.285 Btu/hr 1,699 800 532 208 532 208 255 766 766 Btu/hr 230 0 2,251 11,783 Btu/hr 200 y 1 /1,2i58 PT. F 0 1� RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 12/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 485.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 485.0 X 0.0260 X 56.0 = 706 R-21 Wall (W. 19.2x6.16) (N) 140.0 X 0.0690 X 23.0 = 222 R-21 Wall (W. 19.2x6.16) (E) 270.0 X 0.0690 X 33.0 = 615 R-21 Wall (W. 19.2x6.16) (S) 80.0 X 0.0690 X 26.0 = 144 R-21 Wall (W. 19.2x6.16) (lM 300.0 X 0.0690 X 33.0 = 683 X X = X X = X X = X X = Page Total 2,370 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 21.2 + 12.5 X 21.2 = 264 Window (N) 0.0 X 21.2 + 12.5 X 21.2 = 264 Window (E) 0.0 X 21.2 + 6.0 X 42.5 = 255 Window (E) 0.0 X 21.2 + 10.0 X 42.5 = 425 Window (E) 0.0 X 21.2 + 10.0 X 42.5 = 425 Window (E) 0.0 X 21.2 + 24.0 X 42.5 = 1,021 Window (W) 0.0 X 21.2 + 10.0 X 42.5 = 425 Window (W) 0.0 X 21.2 + 10.0 X 42.5 = 425 X +1 XI - Page Total 3,506 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = E=10 Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.94 X 26.54 X 42 = 1,109 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,215 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 gBtul�/occ. -� p �g 200, � Y (F LA QU NT I Infiltration: 4,771 x o.s4 x 26.54 x 0.00523 = BUILDING & SAFEF DFPT620,' Air Sensible CFM ELA AW AE"i P R O p � I xHGrNISTR ' 1 `k- ' t 1 I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 820 N EnemvPro 5.1 by EnemySoft User Number. 6712 Run Code: 2013-12-21713:41:34 1130TE Qv Page 24 of 2Z - f . , RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 12/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 2,394.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Orientation R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,394.0 0.0260 56.0 262.2 0.0690 23.0 728.2 0.0690 33.0 352.0 0.0690 26.0 152.01 0.0690 33.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 1.3 Page Total Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Internal Gain Orientation (N) (N) (E) (E) (E) (E) (E) (E) (S) Shaded Unshaded Btu/hr 3,486 416 1,658 631 1 6,5371 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 21.2 12.5 21.2 0.0 37.2 71.3 37.2 0.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 1.3 42.5 0.0 21.2 90.0 21.2 Page Total 1.0 Occupants X 230 Btuh/occ. _ 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.94 X 131.00 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 1.0 Occupants X 200 OF LA Q Infiltration: 4,771 X 0.94 X 131.00 X 0.00523 = BUILDING & SAFE Air Sensible CFM ELA DW . A 1_._ P R O V TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I I-Jrl uu11J8-fR1 lr. Btu/hr 264 2,651 55 55 55 55 55 55 1,912 5,159 Btu/hr 230 0 5,476 23,062 Btu/hr Rifle, A-T- . *J 13'660' , 6 `ff. I . a I . • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 1212112013 ROOM INFORMATION DESIGN CONDITIONS Room Name LivinglDininglKitlEntry Outdoor Dry Bulb Temperature 112 OF Floor Area 2,394.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (S) 180.0 X 21.2 + 0.0 X 21.2 = 3,809 Window (lM 18.9 X 21.2 + 5.1 X 42.5 = 617 Window (W) 37.8 X 21.2 + 10.2 X 42.5 = 1,234 X + X — X + X — X + X - X + X - X + X - X +1 XI - Page Total 5,659 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 E ui ment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 131.00 X 42 = 5,476 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,062 Latent Gain I Btu/hr— Occupants 1.0 Occupants X2001 g uh/o c OF LA=�' N120' BUILDING & SAFETY DEPT. Infiltration: 4,771 X 0.94 X 131.00 X0.00523 = �j+3F���'0 3,060 Air Sensible CFM ELA AW FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3.260 DATE BY EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2013-12-21713:41:34 ID: P e-26.of RESIDENTIAL ROOM COOLING LOAD SUMMARY Custom Residence ROOM INFORMATION Room Name Floor Area Indoor Dry E Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.24.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W 19.24.16) R-21 Wall (W. 19.24.16) Bedrooms 2, 3 & 4 Outdoor Dry Bulb Temperature 556.0 ft2 Outdoor Wet Bulb Temperature 70 OF Outdoor Dailv Range: Orientation (E) Date 12/21/2013 112 OF 78 OF 34 OF Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' c = = c c = 556.0 0.0260 56.0 200.0 0.0690 23.0 311.5 0.0690 33.0 30.01 0.0690 26.0 139.0 0.0690 33.0 21.2 8.0 42.5 0.0 21.2 30.0 42.5 0.0 21.2 20.0 42.5 0.0 21.2 40.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnactratinn Window Window Window Window Window Window Window Window Window Orientation (E) (E) (E) (E) (E) (IM (tM (tM (KO Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF 0 c = c a = = c 7.5 21.2 17.5 42.5 7.5 21.2 0.0 42.5 0.0 21.2 8.0 42.5 0.0 21.2 8.0 42.5 0.0 21.2 30.0 42.5 0.0 21.2 20.0 42.5 0.0 21.2 40.0 42.5 0.0 1 21.2 20.0 42.5 0.0 1 21.2 6.0 42.5 Page Total Btu/hr 317 709 31 2,2071 Btu/hr 903 159 340 340 1,276 851 1,701 851 255 6,676 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 30.42 X 42 = 1,272 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10.384 Latent Gain 1•o Occupants X Infiltration: 4,771 X 0.94 X 30.42 X 0.00523 = Air Sensible CFM ELA AW 101 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM uh!/oKc.OF" LA =Q IF JILDiNG & SAFET[ FOR CONSTRUCTI