Loading...
ENC2018-0066VI ta 09 See below for Finance Revenue Codes -GEM qthoEsERr ENCROACHMENT PERMIT PUBLIC WORKS CONSTRUCTION For the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS. DATE: 10/31/2018 LOCATION OF CONSTRUCTION(Street address or Description): CIVIC CENTER CAMPUS; VARIOUS LOCATIONS PURPOSE OF CONSTRUCTION: DIRECTIONAL SIGNS AND OTHER TRAFFIC CONTROL SIGNAGE DESCRIPTION OF CONSTRUCTION: 2018 MASTER CRAFTSMEN EXPO TRAFFIC CONTROL DIMENSION OF INSTALLATION OR REMOVAL: SEE TRAFFIC CONTROL PLAN APPROXIMATE TIME WHEN WORK WILL BEGIN: 11/2/2018 TIME OF COMPLETION: 11/4/2018 ESTIMATED CONSTRUCTION COST: (Including removal of all obstruction, materials, and debris, backfllling, compaction and placing permanent resurfacing and/or replacing improvements) COMMENTS: . NON-PROFIT In consideration of the granting of this permit, the applicant hereby agrees to: Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Notify the Administrative Authority at least twenty-four (24) hours in advance of the time when work will be started at (760) 777-7097. To submit an inspection request, leave a message on the. Inspection Request Hotline at (760) 777-7097 prior to 1:30 P.M. at least twenty-four (24) hours prior to the anticipated inspection. Comply with all applicable City Ordinances, the terms and conditions of the permit and all applicable rup and re ations o4*le City of and to pay for any additional replacement necessary as the result of this work. c--- Signature of Applicant r Agent WEST COAST ARTISTS CORP - RONDA . MILLS 32664 AGUA DULCE CANYON RD AGUA DULCE, CA 91390 (818)621-1350 Name of Applicant (please print) Business Address S Telephone No. TOPS N BARRICADES INC 44-503 JACKSON STREET lNDlO, CA 92201 (760)347-2111 Name of Contractor and Job Foreman Business Address . Telephone No. 787664 . 103875 Contractor's License No. . . City Business License No. UNITED STATES FIRE INSURANCE SRPGAPML-101-0717 S Applicant's Insurance Company Policy Number Finance Revenue Code TOTAL: $0.00 PERMIT NO: ENC2018-0066 DATE ISSUED: ...4c?t/Z ?oi 00 EXPIRATION DATE: NOV ., i-ti 1 BY: .2'. WORK INYECTED BY':5 PERMIT COMPLETION DATES: 51f the work is covered by a Subdivision Improvement Agreement, Subdivider shall request final acceptance of improvements from the City Council. tev Qa&- reu GEM of the DESERT - PUBLIC WORKS PERMIT APPLICATION Tract # Project Name /Th?.,2- C2/1-F731)Wl Y/O Vicinity, —,jq Purpose of Construction (i.e.: Rough Grading, Offsite Street, etc.)__________________ A/2Y 5/iLpU) Description of Construction (i.e.: See Plan Set No. 01234) Dimension of Installation or Removal: Approximate Construction Start Date: ///Z — U1 2019 . Approximate Construction Completion Dale: 1,' / p,' Estimated Construction Cost: $ Estimated Construction Cost shall include the removal of all obstructions, materials, and debris, back-filling, compaction and placing permanent resurfacing and or replacing improvements Contact Name: J( Name of Applióant Applicant Address: Applicant Telephone: Applicant E-mail Address:/iJFô r,7zT( r Name of Contractor: TO 3 .J 42t24 e / RtMf F(-L— Contractor Address:. / Contractor Telephone Number: fQ 2 — T0 7L) Contractor State License Number: Contractor City Business License Number: Contractor E-mail Address: 10- A COPY OF THE CURRENT INSURANCE CERTIFICATE MUST BE PROVIDED '4 Applicant or Contractor General Liability Insurance Company: Ar7AC1f7i Applicant or Contractor General Liability Insurance Policy Number: Office Use Only: Inspection Fee: Permit Fee: 0 As-Built Deposit:___________________________ Dust Control Deposit: Office Use Only: Assigned Permit Number___________________ Approval Date: Expiration Issue Date: Credit Amount: ____ TOTAL FEE DUE: 5 . I Admin Authority: 78495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 760-777-7000 RALPH'S CENTER SC-5 PEdAL EVENT AHEAD J FESTIVAL PARKING 0 0 / OFESc BEA S\ g 178 \ \ Exp. 6.30-19 0" ~ ARTIST PARK114G d SUNLINE /3 LIBRARY CITY HALL '+ L. Q. PARKING CITY NO FESTIVAL HALL cALLE TAMPICO ART PARKING EVENT SITE FESTIVAL PARKING PARKiNG DEAD END FESTIVAL PARKING L) EXIST— TRA .551 NOTES: 1 ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH THE 2014 CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (Ca.M.U.T.C.D.) TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA REPRESENTATIVE. THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME IN ACCORDANCE WITH TRAFFIC CONTROL PLANS. CONTRACTOR SHALL MAINTAIN A MINIMUM 10 (TYP. 12)' TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF CUT AND THE NEAREST TRAFFIC LANE, ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. THIS TRAFFIC CONTROL SHALL BE IN PLACE FROM 6AM NOV 2 UNTIL 6 PM NOV 4. ALL TRAFFIC CONTROL DEVICES SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL HAVE FLASHING LIGHTS. AVD. BERMUDA it DESERT CLUB D FESTIVAL 0 PARKING WWOO BLOCK U NO FESTIVAL PARSING _ EISENHOWER DR. REDUCED TO FIT iol BEN FRANKLIN o SCHOOL 0 imm TPA FIC CONGESTION ST WASHINGTON AND GALE SAMPICO COVE RESIDENTS USE AVE 50 FREE PUBLIC PARKING LOT DC No' rPE!\: MA 17' QSfII4N SELF PARKING _ I NO FESTIVAL TOP Top OLD TOWN PARKING N'L I.. EVENTI I LA QUINTA .11 P FESTIVAL ARK ING PARKIN SELF I [_J PARKING AVID. R 3T I PARKING tCALLE CALLEF TUNA ESTAD0 CALLE CADIZ CALLE CADIZ 1 .FESTIVAL i — - -- - 51i:- - .__•__•___.__- - _iii11 INDICATES AREAS TO POST TEMPORARY NO PARKING RESIDENTS ONLY ON BARRICADES SPACED AT 150' APART INDICATES AREAS FOR PUBLIC STREET PARKING (EXCEPT NOT IN DRIVEWAY, BY FIRE HYDRANTS, FIRE STATION ETC. AS IN THE CALIFORNIA VEHICLE CODE). Reviewed By Date Permit Number Pending Traffic Control Plan For - Master Craftsmen's Expo Prime Contractor Contact West Coast Artists Ronda 818-813-4478 - Traffic Control Design by Prepar By Checllod By Tops N Barricades, Inc. Ron Fifield Phone Speed Limit Date Sheet Number (800)852-TOPS XX 08/21/18 1 REV E City of La Quinta The following General and Special Provisions are attached to and made a part of Permit Number ENC20I8-0066 The following shall always aDDly: ENCROACHMENT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within the City of La Quinta's right of way ONLY. Whenever construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission from abutting property owners. Such authorization must be secured by the permittee prior to starting work. TRACK-LAYING CONSTRUCTION EQUIPMENT: Cleated track-laying construction equipment shall not be permitted to operate on any paved surface unless fitted with smoother-faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving during excavations. Rubber-tired equipment only shall be used in backfill operation in paved areas. If the existing pavement is scarred, spalled, or broken during the term of this contract or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal coat as specified above. PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City Engineer or City of La Quinta Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the project. The City shall be notified twenty-four hours (24) in advance of any traffic detours or delineation. CARE OF DRAINAGE STRUCTURES: Any drainage structure to include corrugated metal pipe, concrete pipe, steel culvert and concrete structures encountered during excavation which necessitate removal shall be replaced in kind. In the-event it becomes necessary to remove or cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains shall be kept free of debris at all times for proper drainage. RIGHT-OF-WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All paved surfaces shall be broomed clean of earth and other objectionable materials Immediately after backfill and compaction. Existing gutter line and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill. DE-WATER OPERTATIONS: If de-watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary. CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time, permittee shall contact this office to obtain the necessary permission. SPECIAL PROVISIONS The following shall apply when Indicated: RI NOTIFICATION: Permittee shall notify the City at (760) 777 - 7097 at least forty-eight hours (48) in advance of starting construction. 0 R2 UTILITY CLEARANCE: (Substructures) Prior to making any excavations within the City of La Quinta right-of-way authorized by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures. Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the permittee. 0 R3 UTILITY CLEARANCE (Surface Structures) No work shall be done under this permit until all utilities are clear of the proposed work site. The permittee shall notify all concerned utility companies of the proposed work. 0 R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced with (0* N/A ) inches of A.C. paving placed on ( N/A ) inches of ( N/A ) aggregate sub-base course having an °R" value of not less than ( N/A ** ) and in conformance with the City of La Quinta Road Improvement Standards and Specifications, Ordinance #461. 0 R5 PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of one-fourth inch (%") to one foot (1'). 0 R6 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as established by a licensed engineer. 0 R7 CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter ( ** N/A ** ) feet shall be removed. Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207. 0 R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property Fine and the existing road paving shall be two and a half inches (2 W) of A.C. paving on (.0* N/A ) of class ( N/A 0*) aggregate base. 0 R9 SIGHT CLEARANCE: Sight Clearance of six-hundred feet (600') in all directions shall be assured and maintained at all times. 0 RIO SOIL STERILIZER: The area to be surfaced shall be treated with soil strerilizer. Rate of application shall comply with the manufacturers specifications. City of La Quinta R11 COORDINATE WORK: The proposed work shall be subordinated to any operation, which the State of California or City of La Quinta may conduct in this area during the period of this permit. Work shall be coordinated with the State or City of La Quinta forces to preclude delay or interference with State or City of La Quinta projects. 19 R12 SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the centerline of all streets or property lines when included shall be completely tied out so they may be readily and correctly, replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be notified upon completion or replacement of all survey monuments for proper clearance. R13 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight edge prior to excavation. Method of pavement cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be used to excavate prior to cutting or pavement.) Excavation material shall be placed in such a position as to best facilitate the general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected. R14 LIMIT OF EXCAVATIONS: Excavations shall be limited to one-thousand feet (1000') of open trench before backfill - operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the protection of the traveling public. The Public Works Inspector shall determine the suitability of excavation barricading in each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the construction material is actually on the work site. El R1 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes R producing and adequately consolidated backfill. Ant material which the City of La Quinta deems unsuitable (spongy or saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or replaced by an approved sand or gravel. E] RIG BACKFILL SAND: Backfill shall be approved transit-mix sand or equivalent and shall be placed on lifts not greater than three feet (3') and vibrated using vibrostamper or equivalent equipment. Alternate methods may be substituted, but in any case, a relative compaction of ninety-five percent (95%) shall be maintained with the structural section of the roadway. Rh 7 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than fifty percent (50%) of the total depth of the trench before flooding or a maximum of five feet (5') lifts where trenches are of excessive depths. Care is to be exercised that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed' so that the. resulting compaction shall not be less than ninety percent (90%) or equivalent to the surrounding ground, whichever Is the greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water supply shall be continuos. El R18 COMPACTION TESTS: If so required by the inspector, compaction test shall be made at intervals of not more than one- thousand (1000') feet and a maximum of one (1)test on each road. One (1) copy of each test shall be forwarded tot the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. RI9 COMPACTION TESTS: If so required by the Inspector, compaction tests shall be made for each crossing or service line. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Sections 6.3.001 of the Standard Specifications, Division of Highways, State of California, dated January 1973. El R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting of two inches (2") of SC-800 shall be placed on a prepared sub-grade. The SC-800 temporary paving shall be placed after a maximum of three-thousand linear feet (3000') or trench has been excavated and backfill operations completed, but in no case shall the placement of the temporary pavement exceed a five (5) day limit. R2I PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of three inches (3") of SC-800 shall be placed immediately. A permanent patch of Asphalt Concrete surfacing per City of La Quinta 'Standard 600 shall be placed no later than (5 ) days after completion of temporary road repair R22 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as determined by the City Engineer. R23 STREET RESTRIPING: Where street striping is still visible on street to be excavated, such striping shall be replaced upon completion of permanent repairs. El R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right-of-way shall be accomplished by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It shall be the responsibility of the permitte to maintain the tree in a vigorous growing condition at its new location. Trees to be removed shall be in sections, which can be handled safely without interference or hazard to highway traffic. The entire width of the tree stump, shall be removed and disposed of so that no debris remains in view of, the highway. The stump hole shall be backfihled and thoroughly compacted as specified in the following paragraph. Where it becomes necessary to restrict traffic, the work shall be restricted to a maximum of five-hundred feet (500') at any one time. Adequate signs, flagmen and or barricades shall be provided to protect the traveling public at all times. Large holes resulting from tree removal shall be backfilled and compacted to not less than ninety percent (90%) or equivalent tot the surrounding ground, whichever is the greater compaction as determined by the impact or field method. Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. PERMIT NO. ENC2018-0066 Master Craftsmen Expo/ Traffic Control and Directional Signs / Civic Center Park; Various Sign Locations In addition to the standard permit conditions, the following shall apply: The applicant shall be available during the event by phone at (818) 621-1350. Pursuant to Section 14.16.320 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), all work shall be performed in accordance with the latest edition of the Standard Specifications For Public Works Contruction (SSPWC) and as directed by and to the satisfaction of the City Engineer. West Coast Artists Corporation (Ronda Mills), hereinafter referred to as "Permittee", shall be responsible for providing continuous dust and erosion control. Streets shall be kept dean. They shall be completely cleaned at the end of each .working day and more frequently, if required. The permittee shall remove all signs immediately after the completion of the festival. Sign removal should be accomplished by the end of 6PM on November 4, 2018. S The permittee shall submit inspection requests by calling the City Inspection Hotline at (760) 777-7097 before 1:30 p.m. and at least twenty-four (24) hours prior to the anticipated inspection. The permittee is responsible for obtaining a valid separate permit from other Cities, or County jurisdictions if any of the work or traffic control devices extend into other Cities, or County right of way. The permittee and/or contractors shall be responsible for taking safety measures and precautions when installing and removing the temporary pole banners near any power lines. Permittee shall assume responsibility for repair of any damaged electrical equipment as a result of work performed under this permit. Pursuant to Section 6.08.050 of the La Quinta Municipal Code (Ordinance 18 § 1, 1982), throughout the work site, the Permittee shall comply with City regulated work hours. Operation and maintenance of equipment within one-half mile of human occupancy shall be performed only during the following time periods: October 1st to April 30: Monday-Friday 7:00 a.m. to 5:30 p.m. Saturday 8:00 a.m. to 5:00 p.m. May 1st to September 30: Monday-Friday 6:00 a.m. to 7:00 p.m. Saturday 8:00 a.m. to 5:00 p.m. Work shall be prohibited on legal holidays and Sundays. Note: Construction work (including setting up traffic control devices) is not permitted on any Arterial street (ie any 4 lane street) before 8:00 a.m. Special Conditions Page 1 of 4 PERMIT NO. ENC2018-0066 Master Craftsmen Expo/ Traffic Control and Directional Signs I Civic Center Park; Various Sign Locations Work within 500 feet of a signalized intersection shall be performed between the hours of 9 a.m. - 3 p.m. Traffic control shall be set up after 9 a.m. and removed before 3 p.m. The Pèrmittee shall contact the City Traffic Signal Division at (760) 777-7070 if signal operation at the intersection is to be altered in any way. Pursuant to Section 14.16.110 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), Permittee shall assume responsibility for repair of any pavement damage to any public or private Street and for any damage to other City streets or facilities as a result of work performed under this permit. Pursuant to Section 14.16.250 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), at residential streets, advance warning signs and traffic control shall be installed and maintained in accordance the latest edition of the California Manual of Uniform Traffic Control Devices (CA MUTCD) or the latest edition of the Work Area Traffic Control Handbook (WATCH). On Collectors to Arterial Streets, the permittee must submit a traffic control plan which shall be from or prepared under the guidance of the latest edition of the California Manual of Uniform Traffic Control Devices (CA MUTCD) or the latest edition of the Work Area Traffic Control Handbook (WATCH). Traffic Control plans not from the CA MUTCD or the WATCH shall be signed and stamped by a civil or traffic engineer registered in the State of California. It shall be the Perrnittee's responsibility to appropriately detour and barricade all construction sites. Pursuant to Section 14.16.290 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), street closures shall not be permitted. A minimum of two (2) travel lanes of paved surface shall be maintained at all times. Prior to excavating, if required, the Permittee shall contact Underground Service Alert at 1-800-422- 4133. It shall be the Permittee's responsibility to notify the Public Works Division of anticipated excavation which impact City facilities, including but not limited to traffic signal conduits and loops, irrigation lines, electrical conduits, and storm drain facilities. Should additional work, materials, or modifications of the work be required in order to meet City standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be performed by the Permittee as directed by and to the satisfaction of the City Engineer at no cost to the City of La Quinta. The City of La Quinta reserves the right to require modifications of the work be made at permittee's sole cost for proper sight distance requirements per guidelines in the AASHTO "A Policy on Geometric Design of Highways and Streets, 5th Edition" or latest, in the installation of all appurtenances abutting and within the public street right-of-way. The issuance of this permit and the City approval of the related construction improvement plans do not provide a vested entitlement for all design parameters that may have been utilized for the plans. As such, plans approved for this permit may be "at risk" for further modifications as it relates to any follow up improvement plan requirements as required by the city or existing errors & omissions by the architect or engineer of record. Special Conditions Page 2 of 4 PERMIT NO. ENC2018-0066 Master Craftsmen Expo/ Traffic Control and Directional Signs I Civic Center Park; Various Sign Locations 17. Pursuant to Section 14.16.370 of the La Quinta Municipal Code (Ordinance 16 § 1 (part), 1982), backfill compaction within street rights-of-way shall conform to Section 306-1.3 of the latest edition of the Standard Specifications for Public Works Construction (SSPWC), except as otherwise specified herein. No excavation or backfill will be required on this project. Reapply if excavation is required. 18. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start of construction, the name of the City approved contractor, who shall submit to the City the following items: General Liability Insurance Company and Policy Number City Business License Contractors State License Number 19. The Permittee or Contractor shall furnish the City satisfactory evidence of insurance in the amounts provided in Engineering Bulletin #97-04 on Indemnification & Insurance Requirements. This insurance shall be kept in full force and effect at all times by Applicant or Contractor during the prosecution of the permitted work and updated Certificate of Liability Insurance shall be submitted to the City. Each policy shall name the City as an additional insured. Permittee agrees to ensure that its vendors, sub-consultants, sub-contractors, and any other party involved with the event, provide the same minimum insurance coverage and endorsements required of Permittee. Permittee agrees to monitor and review all such coverage and assumes all responsibility for ensuring that such coverage is provided in conformity with the requirements of this section. Permittee agrees that upon request, all agreements with vendors, subcontractors, and others engaged in the event will be submitted to City for review. 20. If public traffic lanes are required to be closed, this permit is not valid until the permittee submits, to the Engineering Division, a traffic control plan for review and approval prior to start of construction or parking on the paved RJW. 21. All landscaping, irrigation, decorative rock, decorative concrete, sidewalk, lighting, etc., shall be replaced to its original condition. 22. Access and egress to all local properties shall be maintained at all times. 23. Pursuant to Section 14.16.375 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), permanent pavement replacement shall be completed no later than seven (7) days after the completion of the work. Permanent pavement replacement shall conform to the following conditions: No asphalt work will be required on this project. Reapply if excavation is required. 24. Permittee shall permanently stabilize any and all soil that was disturbed as a result of work performed under this permit with an approved dust control treatment. Soil stabilization shall be done immediately after completing the operation. Special Conditions Page 3 of 4 PERMIT NO. ENC2018-0066 Master Craftsmen Expo/ Traffic Control and Directional Signs / Civic Center Park; Various Sign Locations The City of La Quinta reserves the right to revoke, suspend or void this permit at any time. The permittee shall indemnify, hold harmless and assume the defense of the City from all damages, delay costs, costs or expenses in law or equity that may arise out of work under this permit. Special Conditions Page 4 of 4