Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENC2019-0032
* - CEMof&DESERT -- MAR14 2Ji ENCROACHMENT PERMIT PUBLIC WORKS CONSTRUCTION CflYOFLAQUIN1iL For the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, wal?er mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS. DATE: 3/14/2019 LOCATION OF CONSTRUCTION(Street address or Description): JEFFERSON ST NORTH OF AVE 52 PURPOSE OF CONSTRUCTION: RELOCATE lID ELECTRICAL VAULT FOR SIGHT DISTANCE DESCRIPTION OF CONSTRUCTION: FLORESTA TM36762 RELOCATE lID SWITCH VAULT DIMENSION OF INSTALLATION OR REMOVAL: APPROXIMATE TIME WHEN WORK WILL BEGIN: 3/18/2019 TIME OF COMPLETION: 4/1/2019 ESTIMATED CONSTRUCTION COST: S35M00.00 (Including removal of all obstruction, materials, and debris, backfilling, compaction and placing permanent resurfacing and/or replacing improvements)' COMMENTS: NO TRAFFIC CONTROL DURING THE MUSIC FESTIVALS FROM APRIC111418-2125-28;20197 - --------------.. In consideration of the granting of this permit, the applicant hereby agrees to: Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Notify the Administrative Authority at least twenty-four (24) hours in advance of the time when work will be started at (760) 777-7097. To submit an inspection request leave a message on t!ction Reqiit Hotline at (760) 777-70 77 799 P M at least twenty-four (24) hoü?si1or to the anticipated inspecti. ' Comply with all applicable City Ordinances, the terms and conditions of the permit and a/applicable rules and regulations of the and to pay for any additional replacement necessary as the result of this work. / - ' PtN of AppIi4nt or Ag BEAZER HOMES HOLDINGS - JIM WRIGHT 310 COMMERCE STE 150 IRVINE, CA 92602 36-1192 Name of Applicant (please print) Business Address one No. BEAZER HOMES HOLDINGS LLC 310 COMMERCE STE 150 IRVINE, CA 92602 Name of Contractor and Job Foreman Business Address 818129 ' 763045 Contractor's License No. City Business License No. NAVIGATORS SPECIALTY INSURANCE COMPANY I Applicant's Insurance Company Finance Revenue Code PERMIT INSPECTION TRAFFIC CONTROL ' $640.00 TRAFFIC CONTROL PLAN REVIEW $80.00 TECHNOLOGY ENHANCEMENT FEE $5.00 TOTAL: $725.00 5F17CGL2211541C Policy Number PERMIT NO: ENC2019-0032 DATE ISSUED:.Ll4 EXPIRATION DATE: Si (L4 (t BY: WORK IPECTED BY*: *If the work is covered by a Subdivision Improvement Agreement, Subdivider shall request final acceptance of improvements from the City Council. PUBLIC WORKS DEPARTMENT APPLICATION FOR PERMIT Date: December 18, 2018 Tract No: 36762 Project Name: Floresta (Previously Watermarke) Vicinity: NW Corner of intersection of Avenue 52 and Jefferson St Purpose of Construction (i.e.: Rough Grading, Offsite Street, etc.) Installation of lID elect. vault behind curb - - - Description of Construction (i.e.: See Plan Set No. 01234) Installation of lID elect vault Dimension of Installation or Removal: Frontage along Jefferson Street Approximate Construction Start Date: current Approximate Construction Completion Date: 4/1/19 Estimated Construction Cost: $ 35,000 Estimated Construction Cost shall include the removal of all obstructions, materials, and debris, back -filling, compaction and placing permanent resurfacing and or replacing improvements Contact Name Jim Wright - Phone Number 949-536-1192 Name of Applicant/Owner: :Beazer Homes Holdings, LLC Applicant Address: '310 Commerce, Ste 150- Irvine, Ca 92602 Applicant Telephone Number: 949-536-1192 Applicant E-mail Address: jim.wright@beazer.com - Name of Contractor: Beazer Homes Holdings, LLC Contractor Address: Same as above Contractor Telephone Number: Contractor State License Number: 818129 Contractor City Business License Number: On file at City of La Quinta Contractor E-mail Address:. Jim .wright©Beazer.corn A COPY OF THE CURRENT INSURANCE CERTIFICATE MUST BE PROVIDED '4 * Applicant or Contractor General Liability Insurance Company: NAVIGATORS SPECIALTY INSURANCE GROUP Applicant or Contractor General Liability Insurance Policy Number: SF156GL2489321-C Office Use Only: Inspection Fee: Permit Fee: As-Built Deposit: Dust Control Deposit: Credit Amount: TOTAL FEE DUE: 112115 Office Use Only: Assigned Permit Numb 4rgJD'I Cll 0031 Approval Date: Expiration Date: Issue Date: Administrative Authority: ( 5Q o CUSTOMER TO //INTERCEPT EXISTING 36CND AND RE-ROUTE 34) 6) IC SOUTH TO UN1239958S 0 UN12399 58S CAUTION, MH-1 1 O EXISTING 3-750 MCM UNI162200H € ENERGIZED INTERCEPT /UNDERGROUND ABLE FROM UN8I803 CKTN163 (CND 121 / T-2973-65' 0, N"— UN 1088604P 15KVA EXIST/NG2-6'CNO UN81 80S PM H-11 CURVE DATA TABLE 8 RADIUS < JNTH 12.5' j 90--l 19.63' (/ 250' f0 VAULT DETAIL Ours i Eth VAULT UN12399585 LOOKING NORTH lID \-, U SCALE 1 30 T6 R7,SEC5 flEAZER HI cn.Jn lIT! HOLDINGS, LLC ETCH RELOCATION -t F- i T-2974-65 (/) IE 25KVA A2 (EXTEMPORARY) z 0 w CUSTOMER TO REPLACE U EXISTING SWITCH VAULT RING AND LID TO VAULT LID AND RING REFEF TO DETAIL - LJ_... SHEETS 175-176 OF THE 4'8 .IU P i2264O5V MH-11 JJ D E PG REV 2018 EXISTING 2-5 & 2-6' CND. II WITH C ABLE! CUSTOMER TO INTERCEPT EXISTING 2-5' CAUTION EXISTING UNDERGROUND CABLE AND2-6CNDABANDON AND/ RE-ROUTE.SOUTHTO_......./H II TO BE REMOVED PRIOR TO PERFORMING ANY TYPE OF WORK UN1239958S EXISTING 2-6 CND (CND7-8) CONDUIT NOTES A INSTALL 2-5 CND SCH 40 PVC PER SHOWN LENGTH L.S(REFER TO SHEETS 10-11,104-105, 107-110, 112-1150F THE D E PG REV 482018) UN 1162201 P 300 KVA A INSTALL 2-6 CND SCI 41 PVC PER SHOWN LENGTH (REFER TO SHEETS 10-11 104-105, 107-110, 112-115 OF THE D.E PG. REV 4.8 2018) TRENCHING NOTES: TYPICAL CONTRACTOR SHALL INSTALL 2' LINE GUARD TAPE (RED) 'CAUTION: BURIED ELECTRIC LINE BELOW" REFER TO SHEET 115 OF THE DO PC, REV. 482018) TYPICAL T FROM FACE OF CURB TO CENTER OF TRENCH STRUCTURE DETAILS a LARGE SWITCH PAD REFER TO SHEETS 179-180 OF THE 0 E P.O REV 49 2018 SUBSTRUCTURE LARGE VAULT EQUIPMENT ENCLOSURE U REFER TO SHEETS 175-176 OF THE D.E.P 0. REV. 4.8 2018 TRENCH DETAILS - 2-4 PRI DUCT CONC ENCASED REFER TO SHEETS 109 & 115 OF THE DEED. REV. 482018 1 5-9 PIll. DUCT CONC ENCASED REFER TO SHEETS 109 & 115 OF THE 0 E P,G REV 482018 I-WAY SAFETY, INC SALES-RENTALS MANUFACTURER CIIINO OFFICE - 909-591.1781 L,çgçed4 Symbols: W20--ROAD WORK AHEAD U Sign W20-5(RT)--RIGHT LANE CLOSED AHEAD S Cone wl Collar W4-2(RI)-RIGHT LANE MERGE LEFT CDS(BIKE)-B:KE LANE CLOSED AHEAD = Work Area C30(CA)-LANE CLOSED = Type Ill Barricade C30(BIKE)-BIKE LANE CLOSED w =Arrowboard WU-1 /W16-I=BIKESYMBOL/SHAPETHEROAD R9-9-SIDEWALK CLOSED --Driveway 09-1 -SIDEWAlK CLOSED AHEAD USE OTHER SIDE s =Direction of Travel R9-1lASIDEWALK CLOSED CROSS HERE G20-2-END ROAD WORK -00 SIGN TO SF °l ACED A T -E SOUTH WEST CORNER OF JEFFERSON S. AND PO0EL0 VERANO DR. 4R9 IA 660 NERO NO TAPER arrowboard I 59- 4520-2 -- JEFFERSON ST. (55MPH) 4R9 9 - / 4030)00) JEFFERSON ST. (55MPH) TRAFFIC CONTROL PLAN GENERAL NOTES IC non *7*4 ,flale,4. SI-SI 00I07, 07 -n 2014 P40.14 Ide,at C0' Uo'O' Tj0.. C:o'I,C,. De,c.-, CA VuIcA. 2 64 SIOEO*9 and fla.tnge oalcon'c.o, 0,7* SIlo 01 Ca44o,o,4 5lln<t*7d 0*4.44,0 Sc.2c,00s 3 TM conw.CIO4 .4*00,070* to. SCC*SS 0.6 ady300nl P,0c000e, 0 along y.11on boaroon Typb 00*0 be 00d at, 04 W20-1 ..... 0.1 *e Tye-04 11i 9100.g *000000*90. 0. Ad 09005036 be n.6ect.*d and 00400 tIle 6 Al 0.4,036, 0.36.0360., *005 be 31r M.qbl 040 n 10,00 be 2E m000a,- 6w00 007004 *0. 103,0,3000 0404, .0 toO .0300364 p00*0 *4 00 lone. 009 54400 be 000.00 ,004a000 at 0100.00 .a n.00019 0 pt0*fl 1707*6000*5003360700546, Old 593.0,0035 a 420 bçh 0*1.6, Ni talon doted Adnn9 051- 7 TM Pontr0000 64400 flI009kn 04 C 0001*44,0,0 035,004 0944* Oebfle*505, ",Cade* *54 to .0aoe 010005 ben 40 .336,010*47* dntç nt50oc000 6 TM 0*06.050 .0360.003650. 0045.00., b.ng.dt. 00 pooçe6, .natald v0' So 03507*40*9 0n40r40500 9 Tn. t40.05ot atot 000nr ot 10000 tO 00fl4fl5 W. ID 000tbact.on 0900900*57310 be debduded fl 000*5,0501.510 a.... a See 0,000*PM a 00004040 to olbn p,0004ty to...,, Ii Addtwo*I 0.45* 07,604. 0365* llgno 0, 0.5.0.40. tm0 be .045*054 ese 6.00 Tm.. c009. 50*0 be -ii 0 to. pl03fl041 01.05 33di0n36 9*00.553.00507710 .500,. *oM6, 440 t05* *501 6.ne, d0.e.9 073.6*05.00 A 0.31,0103001040 04p0 OS c007ned.oe ..gn, *436 be deeded toe Cd7 Engesee. boned 4000 bwn10, 0003*31.45 No 0105o.* 00.000,05.0.0036 be 0045'3150 0.0.0.00 tot 40045501700 an and 000 00 *530000 ad 602o' S MooS dtOSomS 00040 atettt lb Ste edge 04* *45940 305.9 nofl.0,w6405 6014,5 Re,t*00e bannk9*. .40 00.0 *4t40 3100 Snn0*TI 0 Retnoate attaIn tqno 010.045000-00.6.09 beLa, '5 Ad 000nolesg 4515. 003609 00.0 poet and n4010095 shot be 1010n,09 by wet S0t*Ea49 to nine, *6040.04 flwfl%01 01.0 to enlalla' 01 ntw4*enp.e.ry ,4603,9 03 oattocbng -1 pen.en.nl ,n..*.,. .1.00 be ,anwn.d P-103 000409.40.0 45 totnOnO 04 nn.03ge .036 0. 5.6.000 to Ste 3001 04 Ste Cy 0.09.5.0 TM 0731.050.33' 0,0004.0 0051 .flan.9en014 P'nde** to 000.001 nto-OfI So Ste 0*05503.0.0,360fl IT TM 00,0,00,0 0636 '004.00 *flfl 0,10 36 tertp.n end 1 51*11444t d.,369e9 0, 01,00.0 Aen.g en. 01e00' to en. .otot.00w. 01 Ole 06, Engoo.w. 0 A n,oenoe, 04 S O... dew.,,. .0*0 b. ,na-.n.n.d between ..ty op.. e.c.&0000 sat .Stacttt treat SW. 0051 10 005.1 9 T. 0004.05.' 5036 p.000. 6.459... 35 9.01313 nec.....) On St. C0t Engotoel F31990 000 cwntoy ott. CS*61.t NE OaQQeS CoSe04 01W 2050 CA ii 70 7'. ow1...oto. 0636 owe3tly 065, ft reQooteteots of 1o005000 00.4.3615 Mt ADA a '405009 10 pedtn*'t 01O01 *36 06*05,3.ttt.., 0000.64041- 0436 *neo p., ADA ,ntwneao. SnO.n 000*4043.00w .6360009404 WV. toO C.4Tont. *40000,0. 24 Pad .096003' LANE CLOSED' C36,CA. *'grn or Typ.-lt 11i a deeded by 03 CAy Eni ewoog0010 eowd.d 00,6 5e SI SW V.353. cionod natal OPEN TRENCH* CDT/CAt .90363.0000400 ngte t00in 1 a... 004001 .d.o..n to Z 04,000 fly 22 TM oontt*cto, tS00t pal .yntbol -UNEVEN LANES STEEL PLATES AHEAD- .e *03601 opto be p**e.n.et .0l.oe d07*60nl *0 0 .400 ot VeIn. P.own.en, 40,0.94..'., oIl *364 0. 90036t4 0036 bOon 0*7.0.0 .09. 01 5o 41 1100.0.03 bate/I/ .014.036 73 TM 0000ento .4436 allO CAUTION STEEL PLATES AHEAD- .ndlo. 600091 ROAD 1.90*400*000*01 .5*0 p4350 bn99Ol9 74 TM 0704.010. 01310 flatly *1.e0Aa45 dOy, Ode to 076.0,1531 3.90009 01,1 afledteC 003IOO 25 Tnt det.cbt. sl noSy .0.d .00004, b.35.on.fl h&n. own.., pd.Ces,0 Ire d.O.ttt*.et 000 II So540I0100.6 - 25 Pro,nje the 0090.00. 623 000* .01001*00 t0060hO0t 01400.. 10,40.00,15. to 0365,00000013.0100 21 The 000ncto SAke cotta a ,nflnwfl 050.3. /5,5,0000*, day,.4 .35*700 the Odyt 0.0.0 095* t0Q5.S* 40*0000 tfltowte003t,00 04 0009.0 tan*19 & *45.0400 4.50 .4034, TI1O .opt. SIM .4gfl*7 Inng 1410b0. eSec 41%0 4110*5*073100 t,.'t* 00,10.04. Wee' 9007 350 350 350 220 SHOU0E9 AUR P 311 . 4C50(BIKE) 4W I- 1 WIE -I 4WL -2(VT) 4072)9105) 4W?0 -5(R) - - -- 4W/.-2(RT) 4.620 5(R) signed 03/13/19 City of La Quinta The following General and Special Provisions are attached to and made a part of Permit Number ENC20I9-0032 - The following shall always apply: ENCROACHMENT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within the City of La Quinta's right of way ONLY. Whenever construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission from abutting property owners. Such authorization must be secured by the permittee prior to starting work. TRACK-LAYING CONSTRUCTION EQUIPMENT: Cleated track-laying construction equipment shall not be permitted to operate on any paved surface unless fitted with smoother-faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving during excavations. Rubber-tired equipment only shall be used in backfill operation in paved areas. If the existing pavement is scarred, spalled, or broken during the term of this contract or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal coat as specified above. PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City Engineer or City of La Quinta Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the project. The City shall be notified twenty-four hours (24) in advance of any traffic detours or delineation. CARE OF DRAINAGE STRUCTURES: Any drainage structure to include corrugated metal pipe, concrete pipe, steel culvert and concrete structures encountered during excavation which necessitate removal shall be replaced in kind. In the event it becomes necessary to remove or cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains shall be kept free of debris at all times for proper drainage. RIGHT-OF-WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All paved surfaces shall be broomed dean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill. DE-WATER OPERTATIONS: If de-watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary. CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time, permittee shall contact this office to obtain the necessary permission. SPECIAL PROVISIONS The following shall apply when indicated: 09 RI NOTIFICATION: Permittee shall be notified the City at (760) 777 - 7097 at least forty-eight hours (48) in advance of starting construction. Z R2 UTILITY CLEARANCE: (Substructures) Prior to making any excavations within the City of La Quinta right-of-way authorized by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures. Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the permittee. R3 UTILITY CLEARANCE (Surface Structures) No work shall be done under this permit until all utilities are clear of the proposed work site. The permittee shall notify all concerned utility companies of the proposed work. 0 R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced with (** N/A ) inches of A.C. paving placed on ( N/A ) inches of ( ** N/A ** ) aggregate sub-base course having an "R° value of not less than ( N/A ** ) and in conformance with the City of La Quinta Road Improvement Standards and Specifications, Ordinance #461. R5 PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of one-fourth inch (W) to one foot (1'). 0 R6 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as established by a licensed engineer. 0 R7 CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter ( ** N/A ) feet shall be removed. Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207. 0 R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property line and the existing road paving shall be two and a half inches (2 W) of A.C. paving on ( N/A ) of class (** N/A **) aggregate base. R9 SIGHT CLEARANCE: Sight Clearance of six-hundred feet (600') in all directions shall be assured and maintained at all times. C3 RIO SOIL STERILIZER: The area to be surfaced shall be treated with soil strenlizer. Rate of application shall comply-with the manufacturers specifications. City of La Quinta 0 RII COORDINATE WORK: The proposed work shall be subordinated to any operation, which the State of California or City of La Quinta may conduct in this area during the period of this permit. Work shall be coordinated with the State or City of La Quinta forces to preclude delay or interference with State or City of La Quinta projects. 0 R12 SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the centerline of all streets or property lines when included shall be completely tied out so they may be readily and correctly, replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be notified upon completion or replacement of all survey monuments for proper clearance. R13 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight edge prior to excavation. Method of pavement cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be used to excavate prior to cutting or pavement.) Excavation material shall be placed in such a position as to best facilitate the general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected. 0 R14 LIMIT OF EXCAVATIONS: Excavations shall be limited to one-thousand feet (1000') of open trench before backfill operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the protection of the traveling public. The Public Works Inspector shall determine the suitability of excavation barricading in each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the construction material is actually on the work site. R15 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes of producing and adequately consolidated backfill. Ant material which the City of La Quinta deems unsuitable (spongy or saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or replaced by an approved sand or gravel. R16 BACKFILL SAND: Backfill shall be approved transit-mix sand or equivalent and shall be placed on lifts not greater than three feet (3') and vibrated using vibrostamper or equivalent equipment. Alternate methods may be substituted, but in any case, a relative compaction of ninety-five percent (95%) shall be maintained with the structural section of the roadway. Rh 7 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than fifty percent (50%) of the total depth of the trench before flooding or a maximum of five feet (5') lifts where trenches are of excessive depths. Care is to be exercised that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the resulting compaction shall not be less than ninety percent (90%) or equivalent to the surrounding ground, whichever is the greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water supply shall be continuos. R18 COMPACTION TESTS: If so required by the inspector, compaction test shall be made at intervals of not more than one- thousand (1000') feet and a maximum of one (1)test on each road. One (1) copy of each test shall be forwarded tot the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. 0 R19 COMPACTION TESTS: If so required by the Inspector, compaction tests shall be made for each crossing or service line. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Sections 6.3.001 of the Standard Specifications, Division of Highways, State of California, dated January 1973. R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting of two inches (2") of SC-800 shall be placed on a prepared sub-grade. The SC-800 temporary paving shall be placed after a maximum of three-thousand linear feet (3000') or trench has been excavated and backfill operations completed, but in no case shall the placement of the temporary pavement exceed a five (5) day limit. 0 R21 PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of three inches (3") of SC-800 shall be placed immediately. A permanent patch of Asphalt Concrete surfacing per City of La Quinta Standard 600 shall be placed no later than (5 ) days after completion of temporary road repair. R22 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as determined by the City Engineer. D R23 STREET RESTRIPING: Where street striping is still visible on street to be excavated, such striping shall be replaced upon completion of permanent repairs. R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right-of-way shall be accomplished by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It shall be the responsibility of the permitte to maintain the tree in a vigorous growing condition at its new location. Trees to be removed shall be in sections, which can be handled safely without interference or hazard to highway traffic. The entire width of the tree stump, shall be removed and disposed of so that no debris remains in view of the highway. The stump hole shall be backfihled and thoroughly compacted as specified in the following paragraph. Where it becomes necessary to restrict traffic, the work shall be restricted to a maximum of five-hundred feet (500') at any one time. Adequate signs, flagmen and or barricades shall be provided to protect the traveling public at all times. Large holes resulting from tree removal shall be backfihled and compacted to not less than ninety percent (90%) or equivalent tot the surrounding ground, whichever is the greater compaction as determined by the impact or field method. Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. PERMIT NO. ENC2019-0032 Floresta I Relocate LID Vault for Sight Distance / Jefferson St North of Ave 52 In addition to the standard permit conditions, the following shall apply: Pursuant to Section 14.16.320 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), all work shall be performed in accordance with the latest edition of the Standard Specifications for Public Works Construction (SSPWC) and as directed by and to the satisfaction of the City Engineer. Prior to commencing the excavation of a trench 5 feet in depth or greater and into which a person will be required to descend, the Contractor shall first obtain a permit to do so from the Division of Industrial Safety pursuant to 7-10.4.1. The City of La Quinta also reserves the right to require modifications of the work be made at permittee's sole cost for further modifications as it relates to any sight distance concerns and/or improvement plan requirements as required by the City Engineer. The City of La Quinta reserves the right to require modifications of the work be made at permittee's sole cost for proper sight distance requirements per guidelines in the AASHTO "A Policy on Geometric Design of Highways and Streets, 5th Edition" or latest, in the installation of all appurtenances abutting and within the public street right-of-way. This permit or copy of it shall be on the work site (usually the job trailer) for inspection during the actual work performed. Beazer Homes Holdings. LLC (Jim Wright), hereinafter referred to as "Permittee", shall be responsible for providing continuous dust and erosion control. Streets shall be kept clean. They shall be completely cleaned at the end of each working day and more frequently, if required. Pursuant to Section 6.08.050 of the La Quinta Municipal Code (Ordinance 18 § 1, 1982), throughout the work site, the Permittee shall comply with City regulated work hours. Operation and maintenance of equipment within one-half mile of human occupancy shall be performed only during the following time periods: October 1st to April 30: Monday-Friday 7:00 a.m. to 5:30 p.m. Saturday 8:00 a.m. to 5:00 p.m. May 1st to September 30: Monday-Friday 6:00 a.m. to 7:00 p.m. Saturday 8:00 a.m. to 5:00 p.m. Work shall be prohibited on legal holidays and Sundays. Note: Construction work (including setting up traffic control devices) is not permitted on any Arterial Street (ie any 4 lane Street) before 8:00 a.m. No traffic control during the music festivals from April 11-14, 18-21, 25-28, 2019. Special Conditions Page 1 of 6 PERMIT NO. ENC2019-0032 Floresta I Relocate III) Vault for Sight Distance / Jefferson St North of Ave 52 10. Work within 500 feet of a signalized intersection shall be performed between the hours of 9 a.m. - 3 p.m. Traffic control shall be set up after 9 a.m. and removed before 3 p.m. The Permittee shall contact the City Traffic Signal Maintenance Division at (760) 777-7070 if signal operation at the intersection is to be altered in any way. 11. The permittee shall not encroach upon private property without prior written approval of the private land owner whom is being encroached upon. 12. The permittee shall submit inspection requests by calling the City Inspection Hotline at (760) 777-7097 before 1:30 p.m. and at least twenty-four (24) hours prior to the anticipated inspection. 13. Pursuant to Section 14.16.110 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), Permittee shall assume responsibility for repair of any pavement damage to any public or private street and for any damage to other City streets or facilities as a result of work performed under this permit. 14. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start of construction, a letter from any owners of the driveways/access ways that will be closed down due to the construction. The letter must be approved by the city and at minimum state from the owner the following: Approval of the construction Plan identification Time Frame of Closure Alternative Routes 15. Any land on which Williamson Act contracts apply shall remain undisturbed. 16. Pursuant to Section 14.16.250 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), at residential streets, advance warning signs and traffic control shall be installed and maintained in accordance the latest edition of the California Manual of Uniform Traffic Control Devices (MUTCD). On Collectors to Major Arterial Streets, the permittee must submit a traffic control plan which shall be prepared under the guidance of the latest edition of the California Manual of Uniform Traffic Control Devices (MUTCD). It shall be the Permittee's responsibility to appropriately detour and barricade all construction sites. Pursuant to Section 14. 16.290 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), street closures shall not be permitted. A minimum of two (2) travel lanes of paved surface shall be maintained at all times. 17. Prior to excavating, if required, the Permittee shall contact Underground Service Alert at 1-800-422- 4133. It shall be the Permittee' s responsibility to notify the Public Works Department of anticipated excavation which impact City facilities, including but not limited to traffic signal conduits and loops, irrigation lines, electrical conduits, and storm drain facilities. Special Conditions Page 2 of 6 PERMIT NO. ENC2019-0032 Floresta / Relocate lID Vault for Sight Distance I Jefferson St North of Ave 52 18. Should additional work, materials, or modifications of the work be required in order to meet City standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be performed by the Permittee as directed by and to the satisfaction of the City Engineer at no cost to the City of La Quinta. 19. The permittee shall be responsible for calling the city inspector to arrange the city inspector to observe random trench compaction testing performed by a city approved material testing firm. If the inspector's phone number is unknown, the permittee shall call the Public Works front counter phone at 777-7075 or the Associate Engineer at 777-7047 to determine the city inspector's phone number. The inspector shall determine the number and location of the test location/s. The above testing does not relieve the permittee's responsibility for future repairs due to settlement at and near the locations of the work area. Materials testing must be performed under direct supervision of a California Registered Civil Engineer. 20. The issuance of this permit and the City approval of the related construction improvement plans do not provide a vested entitlement for all design parameters that may have been utilized for the plans. As such, plans approved for this permit may be "at risk" for further modifications as it relates to any follow up improvement plan requirements as required by the city or existing errors & omissions by the architect or engineer of record. 21. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start of construction, the name of the City approved contractor, who shall submit to the City the following items: General Liability Insurance Company and Policy Number City Business License Contractors State License Number 22. The Applicant or Contractor shall furnish the City satisfactory evidence of insurance in the amounts provided in the Engineering Bulletin for Indemnification & Insurance Requirements. This insurance shall be kept in full force and effect at all times by Applicant or Contractor during the prosecution of the permitted work and updated Certificate of Liability Insurance shall be submitted to the City. Each policy shall name the City as an additional insured. 23. The permittee shall haul all offsite debris to a certified landfill. Prior to hauling debris, the permittee shall inform the City (Inspection staff or 777-7047) of the name and location of the certified dump site. 24. If public traffic lanes are required to be closed, this permit is not valid until the permittee submits, to the Design and Development Department, a traffic control plan for review and approval prior to start of construction or parking on the paved R/W. 25. The permittee is required to provide an informative message board (approved by the City Engineer) informing the commuters using the affected roadways of Possible traffic delays Time of construction Alternate routes. The message board shall be provided for the commuters 48 hours prior to the start of traffic delays, and the entire message should be readable with one pass at the posted speed limit. Special Conditions Page 3 of 6 PERMIT NO. ENC2019-0032 Floresta / Relocate III) Vault for Sight Distance I Jefferson St North of Ave 52 26. Pursuant to Section 14.16.370 of the La Quinta Municipal Code (Ordinance 10 § I (part), 1982), backfill compaction within street rights-of-way shall conform to Section 306-1.3 of the latest edition of the Standard Specifications for Public Works Construction (SSPWC), except as otherwise specified herein. Native material may be used as backfill material provided that minimum compaction, achieved in the manner prescribed herein, is achieved. Backfill shall be performed by mechanical means; no water densified compaction via jetting or flooding or other means shall be allowed. It shall be the Permittee's responsibility to provide appropriate geotecimical supervision, testing, and inspection, onsite, at all times during backfill operations. Backfill compaction shall be achieved by the following conditions: When a firm foundation is not encountered due to soft, spongy or other unsuitable material, such material shall be removed to the limits directed by the Geotechnical Inspector and/or the City Inspector and the resulting excavation backfilled with pipe bedding material. Backfill materials shall be brought to or maintained at appropriate moisture content for compaction. The appropriate moisture content range shall be established at the onset of the project and ensured prior to use of the materials through progress testing on the stockpiles. The first length of trench backfilled shall be backfilled in the presence of the City Inspector. Compaction shall be tested at random depths at approximate three-foot vertical intervals as backfill is placed to ensure the effectiveness of the compaction methods and to establish the depth of lift that can be compacted. If lifts greater than one foot are attempted in this trial length of trench, compaction tests shall be taken within the lifts to ensure that the full depth of the lift is compacted. Upon satisfactory completion of this portion of trench, the City Inspector shall establish the maximum lift thickness to be compacted for the remainder of the project. In subsequent lengths of trench, the frequency of compaction tests shall equal one per each lift of backfill, per 300 linear feet of open trench, at randomly selected locations within the open length of trench. The depth of the randomly selected compaction tests shall also be randomly selected except that where multiple tests are required in a given length of trench, the tests shall be no closer than three feet (vertically) from each other. If any compaction test fails, previously placed backfill (in the same length of open trench or previous lengths of trench) which is represented by the failing test (as determined by the City Inspector), shall be tested for compliance with compaction requirements. All costs incurred due to the conditions above shall be borne by the Permittee. Copies of all test results shall be furnished to the City Inspector. Special Conditions Page 4 of 6 PERMIT NO. ENC2019-0032 Floresta / Relocate lID Vault for Sight Distance / Jefferson St North of Ave 52 All excavations within City of La Quinta right-of-way shall be backfihled, and temporarily paved if within the existing travelway, at the end of every workday as directed by and to the satisfaction of the City Engineer for the protection of the public. Lengths of open trench shall not greatly exceed that which can not be backfihled in the same day. Excavated trenches shall not be allowed open overnight; however, Permittee may leave a length of excavated trench, not to exceed twenty (20) feet in length, open overnight at a point where construction will begin the next day, provided that this length of trench is completely covered by steel plating. All landscaping, irrigation, decorative rock, decorative concrete, lighting, etc., shall be replaced to its original condition. Access and egress to all local properties shall be maintained at all times. Pursuant to Section 14.16.375 of the La Quinta Municipal Code (Ordinance 10 § I (part), 1982), permanent pavement replacement shall be completed no later than seven (7) days after the completion of the work. Permanent pavement replacement shall conform to the following conditions: Existing asphalt concrete pavement shall be sawcut one (1) foot beyond trench edges. Edges shall be straight and clean. Permanent pavement replacement structural section, within all trenches, shall be 1" thicker than existing of asphalt concrete over the same existing thickness of crushed aggregate base or crushed miscellaneous base, meeting the requirements of Sections 200-2.2 and 200-2.4 of the Standard Specifications for Public Works Construction. The replaced pavement and base material shall be compacted to 95% relative compaction and respectively tested, for each 300 linear feet of trench. Verify exact structural replacement section thicknesses with the City prior to installation. Permanent pavement replacement shall be installed using a City approved 3/4" max medium asphalt concrete as the base course lift and a City approved ½" max medium finish course lift for capping. Asphalt concrete mix design shall be approved by the City prior to its placement. Cold-Mill and Overlay - The existing pavement which was properly protected in place during the trenching operation located adjacent to the trench saw cut shall be cold-milled to a depth of 0.10 feet with butt joint created next to the existing unmilled pavement surface. The cold-milled area and base asphalt concrete in the trench area shall be overlaid with a City approved C2-AR-4000 asphalt concrete mix. The width of the cold milling area shall be as follows: For longitudinal trenches located in a parking lane: three (3) feet outside the sawcut removal lines. For longitudinal trenches located in a traffic lane: three (3) feet outside the sawcut removal lines, or to the lane line striping, whichever is greater. . For transverse trenches across existing Street: two (2) feet outside the sawcut removal lines. Special Conditions Page 5 of 6 PERMIT NO. ENC2019-0032 Floresta I Relocate III) Vault for Sight Distance / Jefferson St North of Ave 52 If grinding and capping operations are not performed in the same day as base paving operations, the base course lift of 3/4" max medium asphalt concrete shall be installed from saw-cut edge to saw-cut edge flush with the existing street surface. The base course lift of paving shall not be left 0.10' low in anticipation of grinding and capping. Any existing lane striping or any existing detour lane striping affected by this resurfacing shall be replaced in kind by the Permittee, as directed by and to the satisfaction of the City Engineer. Affected traffic signal loops shall be removed and replaced in kind. The finished pavement surface shall be smooth, consistent, and shall conform to the surrounding grades. Permittee shall permanently stabilize any and all soil that was disturbed as a result of work performed under this permit with an approved dust control treatment. Soil stabilization shall be done immediately after completing the operation. Pursuant to Chapter 12.56 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982) the City has designated certain city streets as Truck Routes. The weight limit for restricted streets (i.e., streets not part of the Truck Route network) is three (3) tons; trucks exceeding the weight limit may use a restricted street if making a delivery or pickup on the subject Street, or if this permit specifically grants permission to use the Street to deliver street construction materials and/or equipment. The City of La Quinta reserves the right to revoke, suspend or void this permit at any time. The permittee shall indemnify, hold harmless and assume the defense of the City from all damages, delay costs, costs or expenses in law or equity that may arise out of work under this permit. If it is the intent of the permittee to cut the pavement and have it restored by a third party, the permittee shall postpone cutting the pavement until the intended third party has acquired a permit from the City to perform the required restoration work. Special Conditions Page 6 of 6