ENC2019-0091ta Q9 iA
- GEM oftise DESERT - -
ENCROACHMENT PERMIT
PUBLIC WORKS CONSTRUCTION
See below for Finance Revenue Codes
P NOV 122019
For the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mainCU5W1JjNpubIic works
improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS. DESIGN &DEVELOpMPJJTDEPARTMENT
DATE: 12/23/2019
LOCATION OF CONSTRUCTION (Street address or Description): JEFFERSON AT AVE 48. 50. & HIDEWAY CLUB
PURPOSE OF CONSTRUCTION: INSTALL NEW SEWER, FIllINGS, AND VALVES: SEE CVWD PLANS
DESCRIPTION OF CONSTRUCTION: CVWD JEFFERSON STREET SEWER BYPASS PROJECT
DIMENSION OF INSTALLATION OR REMOVAL: 20 EA POSSIBLY AVERAGE 20'X 20'
APPROXIMATE TIME WHEN WORK WILL BEGIN: 11/13/2019 TIME OF COMPLETION: 11/20/2020
ESTIMATED CONSTRUCTION COST: S1.000.000.00 (Including removal of all obstruction, materials, and debris, backfilling, compaction and
placing permanent resurfacing and/or replacing improvements)
COMMENTS: [NO WOAb1JRiNG'Gö[FtbUR ONJA i5192O20MUSICE AESbNAPR
In consideration of the granting of this permit, the applicant hereby agrees to:
Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all
penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property
happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application.
Notify the Administrative Authority at least twenty-four (24) hours in advance of the time when work will be started at (760) 777-7097. To
submit an inspection request, leave a message on the Inspection Re uest Hotline at(76O)7fl-7097i6S13O_PM?at least twenty-four (24)
hours prior to the anticipated inspection.
JL
Comply with all applicable City Ordinances, the terms and conditions of the permit and all applicable rules and regulations of the Cy of La
Quinta and to pay for any additional replacement necessary as the result of this work.
Signature of ApWant or Agent
JONES BROTHERS CONSTRUCTION
COMPANY - MIKE JONES P 0 BOX 905 COACHELLA, CA 92236
Name of Applicant (please print) Business Address
JONES BROTHERS CONSTRUCTION
COMPANY INC P 0 BOX 905 COACH ELLA, CA 92236
Name of Contractor and Job Foreman Business Address
406921 LIC-0000153
Contractor's License No. City Business License No.
TRAVELERS INDEMNITY COMPANY OF CT DT22-CO-0N398581-TCT-19
Applicant's Insurance Company Policy Number
(760)861-1813
Telephone No.
(760)347-2291
Telephone No.
Finance Revenue Code
PERMIT INSPECTION
EXCAVATION $725.00
TRAFFIC CONTROL $3,784.00
TECHNOLOGY ENHANCEMENT FEE $5.00
TOTAL: $0.00
PERMIT NO: ENC2019-0091
DATE ISSUED:
EXPIRATIO N DATE
.
WORK SPECTED BY*:
PERMIT COMPLETION DATE*:
1f the work is covered by a Subdivision Improvement Agreement,
Subdivider shall request final acceptance of improvements from the
City Council.
L 2019
PUBLIC WORKS DEPARTMENT
APPLICATION FOR PERMIT
Tract No Project Name Jefferson St Sewer Bypass
Vicinity:Jefferson st+Hideàway/Jefferson St + Ave 50/ Jefferson St + AVe 481
Purpose of Construction (i.e.: Rough Grading, Offsite Street. etc.)___________________
InstaII new sewer, fittings and valves
- -. - - - - -
Description of Construction (i.e.: See Plan Set No. 01234)
Excavate, ove, re e an remplacd restore paving
Dimension of Installation or Removal:
20 ea possibly average 20' x 20'
Approximate Construction Start Date: ASAP - waiting on material exp Nov 13, 2019
Approximate Construction Completion Date: 1146i_20 2019
Estimated Construction Cost: 0,606,060. -
Estimated Construction Cost shall include the removal ol'all obstructions, materials, and debris, hack-tilling, compaction and
placing permanent resurfacing and or replacing improvements
Contact Name Mike Jones Phone Number 760 861 1813
Name of Applicant/Owner: Jones Bros Construction Compiny
Applicant Address: '06b7ox 905, Coachella, Ca 92236
Applicant Telephone Number: 760.347.2291
Applicant E-mail Address:eiones@Jonesbrothers.net -
Name of Contractor: .LofleS Bros Construction
Contractor Address: 100 Box 905, Coachella, Ca 92236 -
Contractor Telephone Number: 760 341.2291
Contractor State License Number: 406921
Contractor City Business License Number: 066O153 -
Contractor E-mail betsybannafljonesbrothers.flet
10- A COPY OF THE CURRENT INSURANCE CERTIFICATE MUST BE PROVIDED I
_LkAiLt or Contractor General Liability Insurance Company:_____
- -
Travelers
Applicant or Contractor General Liability Insurance Policy Number:
:DT22-CO-0N398581-TCT-19
ct $7r
rc
1$-
-
4L4Si
Office Use Only:
Inspection Fee:
l'crmit Fee:
tW c-i q
As-Built
Deposit:
Dust Control
Deposit:
Credit
Amount:
TOTAL FEE DUE: 't•s' L/
Office Use Only:
Assigned Permit Number ,JC,_ooCJ I
Approval Date:
Expiration
Date:
Issue
Date:
Administrative Authority:
lication
City of La Quinta
The following General and Special Provisions are attached to and made a part of
Permit Number ENC20I9-0091
The following shall always apply:
ENCROACHMENT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within the City of La Quinta's right of way
ONLY. Whenever construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission
from abutting property owners. Such authorization must be secured by the permittee prior to starting work.
TRACK-LAYING CONSTRUCTION EQUIPMENT: Cleated track-laying construction equipment shall not be permitted to operate on any paved
surface unless fitted with smoother-faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving
during excavations. Rubber-tired equipment only shall be used in backfill operation in paved areas. If the existing pavement is scarred, spelled,
or broken during the term of this contract or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced
over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal coat as specified above.
PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City
Engineer or City of La Quinta Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the
project. The City shall be notified twenty-four hours (24) in advance of any traffic detours or delineation.
CARE OF DRAINAGE STRUCTURES: Any drainage structure to include corrugated metal pipe, concrete pipe, steel culvert and concrete
structures encountered during excavation which necessitate removal shall be replaced in kind. In the event it becomes necessary to remove or
cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains
shall be kept free of debris at all times for proper drainage.
RIGHT-OF-WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All
paved surfaces shall be broomed clean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line
and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker
shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill.
DE-WATER OPERTATIONS: If de-watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the
responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary.
CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for
the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time,
permittee shall contact this office to obtain the necessary permission.
SPECIAL PROVISIONS
The following shall apply when indicated:
RI NOTIFICATION: Permittee shall notify the City at (760) 777 - 7097 at least forty-eight hours (48) in advance of starting
construction.
0 R2 UTILITY CLEARANCE: (Substructures) Prior to making any excavations within the City of La Quinta right-of-way authorized
by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures.
Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the
permittee.
R3 UTILITY CLEARANCE (Surface Structures) No work shall be done under this permit until all utilities are clear of the
proposed work site. The permittee shall notify all concerned utility companies of the proposed work.
R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced
with (" N/A ) inches of A.C. paving placed on ( N/A ) inches of ( N/A ** ) aggregate sub-base course having an
"R" value of not less than ( " N/A ** ) and in conformance with the City of La Quinta Road Improvement Standards and
Specifications, Ordinance #461.
R5 PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of
one-fourth inch (W) to one foot (1').
R6 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as establishedby
a licensed engineer.
0 Ri CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter ( N/A ) feet shall
be removed. Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and
concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207.
R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property
Fine and the existing road paving shall be two and a hall inches (2 V2") of A.C. paving on (** N/A ** ) of class ( N/A **)
aggregate base.
0 R9 SIGHT CLEARANCE: Sight Clearance of six-hundred feet (600') in all directions shall be assured and maintained at all
times.
RIO SOIL STERILIZER: The area to be surfaced shall be treated with soil strenlizer. Rate of application shall comply with the
manufacturers specifications.
City of La Quinta
R11 COORDINATE WORK: The proposed work shall be subordinated to any operation, which the State of California or City of
La Quinta may conduct in this area durinj the period of this permit. Work shall be coordinated with the State or City of La
Quinta forces to preclude delay or interference with State or City of La Quinta projects.
R12 SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the
centerline of all streets or property lines when included shall be completely tied out so they may be readily and correctly,
replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties
to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be
notified upon completion or replacement of all survey monuments for proper clearance.
Z R13 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight edge prior to excavation. Method of pavement
cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be
used to excavate prior to cutting or pavement.) Excavation material shall be placed in such a position as to best facilitate the
general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected.
19 RI4 LIMIT OF EXCAVATIONS: Excavations shall be limited to one-thousand feet (1000') of open trench before backfill
operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the
protection of the traveling public. The Public Works Inspector shall determine the suitability of excavation barricading In
each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the
construction material is actually on the work site.
R15 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes
R producing and adequately consolidated backfill. Ant material which the City of La Quinta deems unsuitable (spongy or
saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or
replaced by an approved sand or gravel.
D RI BACKFILL SAND: Backfill shall be approved transit-mix sand or equivalent and shall be placed on lifts not greater than
three feet (3') and vibrated using vibrostamper or equivalent equipment. Alternate methods may be substituted, but in any
case, a relative compaction of ninety-five percent (95%) shall be maintained with the structural section of the roadway.
C3 R17 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than fifty percent (50%) of the total depth of the
trench before flooding or a maximum of five feet (5') lifts where trenches are of excessive depths. Care is to be exercised
that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the
resulting compaction shall not be less than ninety percent (90%) or equivalent to the surrounding ground, whichever is the
greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to
retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water
supply shall be continuos.
R18 COMPACTION TESTS: If so required by the inspector, compaction test shall be made at intervals of not more than one-
thousand (1000') feet and a maximum of one (1)test on each road. One (1) copy of each test shall be forwarded tot the City
Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section
6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973.
RI COMPACTION TESTS: If so required by the Inspector, compaction tests shall be made for each crossing or service line.
One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs.
Compaction tests shall be made as outlined in Sections 6.3.001 of the Standard Specifications, Division of Highways, State
of California, dated January 1973.
0 R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting
of two inches (2") of SC-800 shall be placed on a prepared sub-grade. The SC-800 temporary paving shall be placed after
a maximum of three-thousand linear feet (3000') or trench has been excavated and backfill operations completed, but in no
case shall the placement of the temporary pavement exceed a five (5) day limit.
0 R21 PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of
two inches (2") of SC-800 shall be placed immediately. A permanent patch of Asphalt Concrete surfacing per City of La
Quinta Standard 600 shall be placed no later than (5 ) days after completion of temporary road repair.
R22 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as
determined by the City Engineer.
0 R23 STREET RESTRIPING: Where street striping is still visible on street to be excavated, such striping shall be replaced upon
completion of permanent repairs.
R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right-of-way shall be accomplished
by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It
shall be the responsibility of the permitte to maintain the tree in a vigorous growing condition at its new location.
Trees to be removed shall be in sections, which can be handled safely without interference or hazard to highway traffic. The
entire width of the tree stump, shall be removed and disposed of so that no debris remains in view of the highway. The
stump hole shall be backfilled and thoroughly compacted as specified in the following paragraph. Where it becomes
necessary to restrict traffic, the work shall be restricted to a maximum of five-hundred feet (500') at any one time. Adequate
signs, flagmen and or barricades shall be provided to protect the traveling public at all times.
Large holes resulting from tree removal shall be backfilled and compacted to not less than ninety percent (90%) or
equivalent tot the surrounding ground, whichever is the greater compaction as determined by the impact or field method.
Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California,
dated January 1973.
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
In addition to the standard permit conditions, the following shall apply:
Pursuant to Section 14.16.320 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), all
work shall be performed in accordance with the latest edition of the Standard Specifications For Public
Works Construction (SSPWC) and as directed by and to the satisfaction of the City Engineer.
The permittee may only work at night if approved by the City Manager. Night work maybe halted if the
city receives complaints about the work.
This permit or copy of it shall be on the work site (usually the job trailer) for inspection during the
actual work performed.
The permittee shall submit inspection requests by calling the City Inspection Hotline at (760) 777-7097
before 1:30 p.m. and at least twenty-four (24) hours prior to the anticipated inspection.
Prior to commencing the excavation of a trench 5 feet in depth or greater and into which a person will
be required to descend, the Contractor shall first obtain a permit to do so from the Division of Industrial
Safety pursuant to 7-10.4.1.
Jones Brothers Construction Company (Mike Jones), hereinafter referred to as "Permittee", shall be
responsible for providing continuous dust and erosion control.
Streets shall be kept clean. They shall be completely cleaned at the end of each working day and more
frequently, if required.
Pursuant to Section 6.08.050 of the La Quinta Municipal Code (Ordinance 18 § 1, 1982), throughout the
work site, the Permittee shall comply with City regulated work hours. Operation and maintenance of
equipment within one-half mile of human occupancy shall be performed only during the following time
periods:
October 1st to April 30: Monday-Friday 7:00 a.m. to 5:30 p.m.
Saturday 8:00 a.m. to 5:00 p.m.
May 1st to September 30: Monday-Friday 6:00 a.m. to 7:00 p.m.
Saturday 8:00 a.m. to 5:00 p.m.
Work shall be prohibited on legal holidays and Sundays.
Note: Construction work (including setting up traffic control devices) is not permitted on any Arterial
street (ie any 4 lane street) neither before 8:30 a.m. nor after 4:30 p.m.
Special Conditions Page I of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
9. Work within 500 feet of a signalized intersection shall be performed between the hours of 9 a.m. - 3
p.m. Traffic control shall be set up after 9 a.m. and removed before 3 p.m. The Permittee shall contact
the City Traffic Signal Maintenance Division at (760) 777-7070 if signal operation at the intersection is
to be altered in any way.
10. The permittee and/or contractor placing engineered fill must provide adequate time and safety for the
Geotechnical Engineer of Record to perform soils testing during engineered fill placement. The testing
frequency shall be determined by the Geotechnical Engineer of Record such that the fill can be
determined to be placed according to the city approved plans.
11. The permittee and/or contractor shall provide surveyor staking information adequate for the City
Inspector to determine horizontal and vertical locations relative to the approved city plans. The
minimum required wood lath type stakes shall be placed at all proposed building corners, and they shall
state the horizontal location relative to building corner and the elevation of the top of hub next to the
lath.
12. Pursuant to Section 14.16.110 of the La Quinta Municipal Code (Ordinance 10 § I (part), 1982),
Permittee shall assume responsibility for repair of any pavement damage to any public or private Street
and for any damage to other City streets or facilities as a result of work performed under this permit.
13. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to
Start of construction, a letter from any owners of the driveways/access ways that will be closed down
due to the construction. The letter must be approved by the city and at minimum state from the owner
the following:
Approval of the construction
Plan identification
Time Frame of Closure
Alternative Routes
14. The permittee shall place temporary no parking signs along the parking area affected by the
construction. The signs shall be placed along the area 48hrs prior to the start of closing the area, and
removed immediately after the construction completion date.
15. Jones Brothers Construction Company (Mike Jones), hereinafter referred to as "Permittee", shall be
responsible for providing continuous dust and erosion control during construction material hauling
procedures.
The following Fugitive Dust Control rules shall apply during soil import/export activities:
A valid grading permit shall be active at both the import and export site
The import/export material during hauling shall be near 70% optimum moisture content.
Street cleaning shall occur, as necessary, at import and export location.
Trucks hauling export or import material must maintain 6 inches of freeboard and be tarped.
The haul route shall be attached to this permit or a City approved plan.
Special Conditions Page 2 of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
Prior to excavating, if required, the Permittee shall contact Underground Service Alert at 811. It shall
be the Permittee's responsibility to notify the Public Works Department of anticipated excavation
which impact City facilities, including but not limited to traffic signal conduits and loops, irrigation
lines, electrical conduits, and storm drain facilities.
Pursuant to Section 14.16.250 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), at
residential streets, advance warning signs and traffic control shall be installed and maintained in
accordance the latest edition of the California Manual of Uniform Traffic Control Devices (CA
MUTCD) or the latest edition of the Work Area Traffic Control Handbook (WATCH).
On Collectors to Arterial Streets, the permittee must submit a traffic control plan which shall be from or
prepared under the guidance of the latest edition of the California Manual of Uniform Traffic Control
Devices (CA MUTCD) or the latest edition of the Work Area Traffic Control Handbook (WATCH).
Traffic Control plans not from the CA MUTCD or the WATCH shall be signed and stamped by a civil
or traffic engineer registered in the State of California. It shall be the Permittee's responsibility to
appropriately detour and barricade all construction sites.
Pursuant to Section 14.16.290 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982),
street closures shall not be permitted. A minimum of two (2) travel lanes of paved surface shall
be maintained at all times.
Should additional work, materials, or modifications of the work be required in order to meet City
standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be
performed by the Permittee as directed by and to the satisfaction of the City Engineer at no cost to the
City of La Quinta.
The City of La Quinta reserves the right to require modifications of the work be made at permittee's
sole cost for proper sight distance requirements per guidelines in the AASHTO "A Policy on Geometric
Design of Highways and Streets, 5th Edition" or latest, in the installation of all appurtenances abutting
and within the public street right-of-way.
The permittee shall be responsible for notifying the inspection staff of import fill and overexcavated
areas on a daily base's. If the inspector's phone number is unknown, the permittee shall call the Public
Works front counter phone at 777-7075 or the Associate Engineer at 777-7047 to determine the city
inspector's phone number.
If the imported fill or overexcavated locations indicate to the inspector that inadequate soils exist based
on the criteria set forth in the Project Soils Report, Public Works Greenbook, or California Building
Code, the Public Works inspector may halt grading operations until the inadequate soil has either been
removed or the Public Works Director authorizes grading to continue.
The above testing or observations does not relieve the permittee's responsibility for future repairs due to
settlement at and near the locations of the work area.
Prior to the city issuing a building permit, the permittee's Geotechnical Engineer of Record shall submit a
certified letter indicating that the grading has been completed per the approved plan. A compaction report
on all fill is required following pad certification and prior to building permit issuance.
Special Conditions Page 3 of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
21. The permittee shall be responsible for calling the city inspector to arrange the city inspector to observe
random trench compaction testing performed by a city approved material testing firm. If the inspector's
phone number is unknown, the permittee shall call the Public Works front counter phone at 777-7075 or
the Associate Engineer at 777-7047 to determine the city inspector's phone number. The inspector shall
determine the number and location of the test location/s. The above testing does not relieve the permittee's
responsibility for future repairs due to settlement at and near the locations of the work area. Materials
testing must be performed under direct supervision of a California Registered Civil Engineer.
22. The issuance of this permit and the City approval of the related construction improvement plans do not
provide a vested entitlement for all design parameters that may have been utilized for the plans. As such,
plans approved for this permit may be "at risk" for further modifications as it relates to any follow up
improvement plan requirements as required by the city or existing errors & omissions by the architect or
engineer of record.
23. The permittee is responsible for obtaining a valid separate permit from other Cities, County jurisdictions,
or other agencies if any of the work or traffic control devices extend into the other Cities, County, or
agencies right of way.
24. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start
of construction, the name of the City approved contractor, who shall submit to the City the following items:
General Liability Insurance Company and Policy Number
City Business License
Contractors State License Number
25. The Applicant or Contractor shall furnish the City satisfactory evidence of insurance in the amounts
provided in the Engineering Bulletin for Indemnification & Insurance Requirements. This insurance shall
be kept in full force and effect at all times by Applicant or Contractor during the prosecution of the
permitted work and updated Certificate of Liability Insurance shall be submitted to the City. Each policy
shall name the City as an additional insured.
26. Work within 500 feet of any designated School Zone shall be performed between the hours of 8 a.m. - 1:30
p.m. Traffic control shall be set up after 8 a.m. and removed before 1:30 p.m.
27. The permittee shall not encroach upon private property without prior written approval (submit to the Public
Works Department, attention to the Associate Engineer) of the private land owner whom is being
encroached upon.
28. Prior to excavating in native soils, the owner of the project shall have employed by proposal contract an
archaeological observer for the site excavations within native undisturbed soils. A copy of the contract
must be submitted to the Public Works Department and attention this to the Associate Engineer. If the
archaeologist determines the site note to be required to be observed, please submit a letter signed by the
archaeologist stating their determination.
Special conditions Page 4 or9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) I CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
29. During work hours, the permittee shall provide and maintain a traffic lane that diverts traffic off the paved
roadway. The traffic lane must be located within the existing RJW with the following requirements:
Class II Base with a minimum depth of 2"
A 12 inch thick subgrade layer compacted to 95% based on ASTM D1557
An unobstructed travel width of 10 feet.
In addition, a minimum of 5 feet clearance from open trenches.
A minimum of 2 feet from vertical obstructions like curbs.
Maximum speed of 25 mph
30. The permittee shall haul all offsite debris to a certified landfill. Prior to hauling debris; the permittee shall
inform the City (Inspection staff or 777-7047) of the name and location of the certified dump site.
31. If public traffic lanes are required to be closed, this permit is not valid until the permittee submits, to the
Public Works Department, a traffic control plan for review and approval prior to start of construction or
parking on the paved RJW.
32. The permittee is required to provide an informative message board (approved by the City Engineer)
informing the commuters using the affected roadways of
Possible traffic delays
Time of construction
Alternate routes.
The message board shall be provided for the commuters 48 hours prior to the start of traffic delays, and
the entire message should be readable at the posted speed limit.
33. Pursuant to Section 14.16370 of the La Quinta Municipal Code (Ordinance 10 § I (part), 1982),
backfill compaction within Street rights-of-way shall conform with Section 306-1.3 of the latest edition
of the Standard Specifications For Public Works Construction (SSPWC), except as otherwise specified
herein.
Native material may be used as backfill material provided that minimum compaction, achieved in the
manner prescribed herein, is achieved. Backfill shall be performed by mechanical means; no water
densifled compaction viajetting or flooding or other means shall be allowed. It shall be the Permittee's
responsibility to provide appropriate geotechnical supervision, testing, and inspection, onsite, at all
times during backfill operations.
Backfill compaction shall be achieved by the following conditions:
A. When a firm foundation is not encountered due to soft, spongy or other unsuitable material, such
material shall be removed to the limits directed by the Geotechnical Inspector and/or the City
Inspector and the resulting excavation backfilled with pipe bedding material.
Special Conditions Page 5 of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
Backfill materials shall be brought to or maintained at appropriate moisture content for
compaction. The appropriate moisture content range shall be established at the onset of the
project and ensured prior to use of the materials through progress testing on the stockpiles.
The first length of trench backfilled shall be backfilled in the presence of the City Inspector.
Compaction shall be tested at random depths at approximate three-foot vertical intervals as
backfill is placed to ensure the effectiveness of the compaction methods and to establish the depth
of lift that can be compacted.
If lifts greater than one foot are attempted in this trial length of trench, compaction tests shall be
taken within the lifts to ensure that the full depth of the lift is compacted. Upon satisfactory
completion of this portion of trench, the City Inspector shall establish the maximum lift thickness
to be compacted for the remainder of the project.
In subsequent lengths of trench, the frequency of compaction tests shall equal one per each lift of
backfill, per 300 linear feet of open trench, at randomly selected locations within the open length
of trench.
The depth of the randomly selected compaction tests shall also be randomly selected except that
where multiple tests are required in a given length of trench, the tests shall be no closer than three
feet (vertically) from each other.
If any compaction test fails, previously placed backfill (in the same length of open trench or
previous lengths of trench) which is represented by the failing test (as determined by the City
Inspector), shall be tested for compliance with compaction requirements.
All costs incurred due to the conditions above shall be borne by the Permittee. Copies of all test
results shall be furnished to the City Inspector.
All excavations within City of La Quinta right-of-way shall be backfilled, and temporarily paved if
within the existing travel way, at the end of every workday as directed by and to the satisfaction of the
City Engineer for the protection of the public. Lengths of open trench shall not greatly exceed that
which can not be backfilled in the same day. Excavated trenches shall not be allowed open overnight,
however, Permittee may leave a length of excavated trench, not to exceed twenty (20) feet in length,
open overnight at a point where construction will begin the next day, provided that this length of trench
is completely covered by steel plating.
All landscaping, irrigation, decorative rock, decorative concrete, sidewalk, lighting, eta., shall be
replaced to its original condition.
Access and egress to all local properties shall be maintained at all times.
Special Conditions Page 6 of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project I On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
37. Pursuant to Section 14.16.375 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982),
permanent pavement replacement shall be completed no later than seven (7) days after the completion
of the work. Permanent pavement replacement shall conform to the following conditions:
Existing asphalt concrete pavement shall be sawcut one (1) foot beyond trench edges. Edges shall
be straight and clean.
Permanent pavement replacement structural section, withiniall trenches, shall be 1" thicker than
existing of asphalt concrete over the same existing thickness of crushed aggregate base or crushed
miscellaneous base, meeting the requirements of Sections 200-2.2 and 200-2.4 of the Standard
Specifications for Public Works Construction. The replaced pavement and base material shall be
compacted to 95% relative compaction and respectively tested, for each 300 linear feet of trench.
Verify exact structural replacement section thicknesses with the City prior to installation.
Permanent pavement replacement shall be installed using a City approved 3/4' max medium
asphalt concrete as the base course lift and a City approved Y2" max medium finish course lift for
capping. Asphalt concrete mix design shall be approved by the City prior to its placement.
Cold-Mill and Overlay - The existing pavement which was properly protected in place during the
trenching operation located adjacent to the trench saw cut shall be cold-milled to a depth of 0.10
feet with butt joint created next to the existing unmilled pavement surface. The cold-milled area
and base asphalt concrete in the trench area shall be overlaid with a City approved C2-AR-4000
asphalt concrete mix. The width of the cold milling area shall be as follows:
For longitudinal trenches located in a parking lane: three (3) feet outside the sawcut
removal lines.
For longitudinal trenches located in a traffic lane: three (3) feet outside the sawcut removal
lines, or to the lane line striping, whichever is greater.
For transverse trenches across existing Street: two (2) feet outside the sawcut removal lines.
If grinding and capping operations are not performed in the same day as base paving operations,
the base course lift of 3/4" max medium asphalt concrete shall be installed from saw-cut edge to
saw-cut edge flush with the existing Street surface. The base course lift of paving shall not be left
0.10' low in anticipation of grinding and capping.
Any existing lane striping or any existing detour lane striping affected by this resurfacing shall be
replaced in kind by the Permittee, as directed by and to the satisfaction of the City Engineer.
Affected traffic signal loops shall be removed and replaced in kind. The finished pavement
surface shall be smooth, consistent, and shall conform to the surrounding grades.
Special Conditions Page 7 of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) I CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
Permittee shall permanently stabilize any and all soil that was disturbed as a result of work performed
under this permit with an approved dust control treatment. Soil stabilization shall be done immediately
after completing the operation.
Pursuant to Chapter 12.56 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982) the City
has designated certain city streets as Truck Routes. The weight limit for restricted streets (i.e., streets
not part of the Truck Route network) is three (3) tons; trucks exceeding the weight limit may use a
restricted street if making a delivery or pickup on the subject street, or if this permit specifically grants
permission to use the street to deliver street construction materials and/or equipment.
The. City of La Quinta reserves the right to revoke, suspend or void this permit at any time.
The permittee shall indemnify, hold harmless and assume the defense of the City from all damages,
delay costs, costs or expenses in law or equity that may arise out of work under this permit.
If it is the intent of the permittee to cut the pavement and have it restored by a third party, the
permittee shall postpone cutting the pavement until the intended third party has acquired a permit from
the City to perform the required restoration work.
Flagger Requirements
A. Minimum Requirements
Receive and communicate specific instructions clearly, firmly, and courteously;
Move & maneuver quickly;
Provide clear and positive guidance;
Understand and apply safe traffic control practices;
Recognize dangerous traffic situations in sufficient time to avoid injury.
B. Flagger Safety Apparel
1. Background
Fluorescent orange-red, or
Fluorescent yellow-green
2. Retroreflective material (Orange, yellow, white, silver, yellow-green, or fluorescent
version.
3. Material shall be visible at 1000 ft
4. Apparel shall be designed to identify the wearer as a person
5. Law enforcement personnel should adhere to the same standard
C. Hand-Signaling Devices
1. Stop/Slow paddle octagonal in shape with minimum 18" width and 6" letters. Must
have white legend on red background.
Special Conditions S Page 8 of 9
PERMIT NO. ENC2019-0091
For CVWD (Jones Bros Construction Co) / CVWD Jefferson St Sewer Bypass
Project / On Jefferson St at Ave 48, Ave 50, and Hideaway Club Dr
D. Directing Traffic
1. Only three (3) signals are required.
STOP SLOW PROCEE
E. Flagger Communications
1. If work area is too long for relay (2 flaggers can't see each other)
One flagger given the responsibility to coordinate
Use Radios or
Field phones
F. Flagger warning signs must be removed or covered when flagging is finished, when work is not
going to start immediately, or when work is completed.
Special Conditions Page 9 of 9
I'—
C24577
NO SCALE
VILLAGGIONEk
iIk Uj
C20 (CA) (LT)
will
RI-2 Uj
VII
END EXISTING _
ROA() WORK RI-2
JEFFERSON ST TING
: a-
THE
HIDEAWAY
W20-1
/ ROAD
WORK
'.AHEA.
..: /
/ ------------ - - j,14 / 500' 500' RI-2
R1-2 600' W20-1 C20 (CA) (IT)
Ilvtjj EXISTING
EXISTING
G202
END 4 /
LROAD WORK
600' 600'
Lmum
MUST
st ,
G20-2
500'
NOTES: 1 ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10'(17 TYP.) TRAFFIC LANE WIDTH ATALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK,
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE CITY OF LA QUINTA.
AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES AHEAD" SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH FLASHING LIGHTS.
THIS WORK WILL BE DONE DURING
DAYLIGHT HOURS UNLESS NIGHT IS
NECESSARY DUE TO SEWER FLOW
Pending
Install Jefferson By Pass Sewer
Jones Bros Construction Mike (760) 347-2291
Taft Conid DWp by Pip.sd By Bsdon WATCH pg
Tops N Barricades, Inc. Ron Fifield page 36
(800)852-TOPS 50 11/18/19 1 REV
C20-2
A N A
-
,WORK 1
_4
JEFFERSON ST
END
L ROAD WORK
THIS WORK WILL BE DONE DURING
DAYLIGHT HOURS UNLESS NIGHT IS
NECESSARY DUE TO SEWER FLOW
NOTES: 1. ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICE
S
(
C
A
L
I
F
O
R
N
I
A
M
,
U
.
T
.
C
.
D
.
)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA REPRESENTATIVE. THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME IN ACCORDANCE WITH TRAFFIC CO
N
T
R
O
L
P
L
A
N
S
.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10 (12 TYP.) TRAFFIC LANE WIDTH ATALL TIMES. THERE SHALL BE A MINIMUM 2 BETWEEN THE EDGE OF CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE CITY OF LA QUINTA.
AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES AHEAD" SIGNS ON BARRICADES WITH FLASHING LIGHTS S
H
A
L
L
B
E
P
O
S
T
E
D
)
,
T
H
E
R
O
A
D
S
H
A
L
L
B
E
C
L
E
A
R
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
7 ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH FLASHING LIGHTS.
Pending
Install Jefferson By Pass Sewer
Jones Bros Construction Mike (760) 347-2291
Tops N Barricades, Inc. Ron Fifleld page 36
(800)852-TOPS 50 11/19/19 2 REV
LU I—
620-2
U,
C
U
JEFFERSON ST
351
0-1 C20 (CA) (IT)
011 ROAD
WORK CLD
AHEAD / AHEAD /
AVE 49
a
35O
350'
AVE 50
NO SCALE
II
AHEAD
CITY OF INDlO
350'
W5-1
350'
WI-4 1T1
R3-1 8
350i
~vs
C1 Q-1
- -'.-
-- I-h A jWOR _pff -.
AREAJ
00, \R3- 60j
±$j
Uj FS
Lv4 \
Uj
WI-4(RT
620-2
W20-1
6•
KEEP
620-2
—J
LU
0
-9OUBLE SIDED ULTRA LITE CL
PANEL (NARROW WIDTH)
-
350'
C24577
CITY OF LA QUINTA END
ROAD WORK
W20-5 (MOD N //\\
TEDDED
AHEAD
350'
W20-1
THIS WORK WILL BE DONE
DURING NIGHT TIME HOURS
NOTES: 1. ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA M .U.T.C.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME IN ACCORDANCE WITH TRAFFIC CONTROL PLANS,
CONTRACTOR SHALL MAINTAIN A MINIMUM 10' (12 TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE CITY OF LA QUINTA.
AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES AHEAD" SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL,
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH FLASHING LIGHTS.
THE TRAFFIC SIGNAL AT JEFFERSON & AVE 50 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE. CONTRACTOR SHALL ASSIST ANY PEDESTRIANS TRYING TO CROSS THE STREET.
Pending
Install Jefferson By Pass Sewer
cm
Jones Bros Construction Mike (760) 347-2291
N Barricades, Inc. Ron Fifield page 36
TOPS 50 11/19/19 3REV
THIS WORK WILL BE DONE
DURING NIGHT TIME HOURS
Pending
NO SCALE
CITY OF INDIO
AVE 50
W20.1
C20 (CA) (L
W20-1
Uj AVE 49
620-2
7 L Cl) ,rn,
. JEFFERSON ST
=
'
o'
-'4
V
R3-7-
6 0-0 T \.
r
)
W20-1
U \~20-1
END
z --- WORK
\C2ALT, ! /LE; PANEL
€r
I DOL(NADM)AT
Rj-7 SEE 62-2
Tm ROAD NOTE 1+
WI-4(LT) A/
W20-1
/\
RAO \ W'I RK
A EAO/
NOTES: 1. ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM
VV20-1 00,
JESS ANNE", Flow U*
R1.1
10
'7
TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C.D.)
Vr E1STlG '
600'
lk
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED, ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY
AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA AND/OR CITY OF INDlO REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME 'c
4
W4-2
IN ACCORDANCE WITH TRAFFIC CONTROL PLANS,
CONTRACTOR SHALL MAINTAIN A MINIMUM 10'(1 Z TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF
Øj 350' CUT AND THE NEAREST TRAFFIC LANE,
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE
CITY OF LA QUINTA. AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES
AHEAD' SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH
FLASHING LIGHTS.
THE TRAFFIC SIGNAL AT JEFFERSON & AVE 50 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE. CONTRACTOR SHALL
ASSIST ANY PEDESTRIANS TRYING TO CROSS THE STREET
CITY OF LA QUINTA G
END
ROADWORK
W20-5 (RP
flDI1APD Install Jefferson By Pass Sewer
RIGHT LANE, 500 CLOSED
201 AHEUAD Jones Bros Construction Mike (
1/7 .\ OU1 by Pv.,d By
350' ¶J/ARD \7 Tops N Barricades, Inc. Ron Fifield
AHEAD/ Phm By..dLM* Os
(800)852-TOPS 50 11/19/19
347-2291
i W1tH
tge 36
4 REV
JEFFERSON ST
300' - 600'
C C 24577 i
AVE 50
W20-1
WORK I
AHEAOJ -
nil
350', ¶ I
W205 (MOD 5-:
END
ROADWORK
350'
WI -.1' nT
C30 CA)
C30 A B00\ - 6C
wisr
Tm RI-1
Uj
4EG
CITY OF LA QUIN
CITY OF INDIO
W20-1
WORK AVE
G22
tç 49
7,1
350; 350' 7 350'
NOTES: 1. ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY
AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA AND/OR CITY OF INDIO REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME
IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10' (12' TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2 BETWEEN THE EDGE OF
CUT AND THE NEAREST TRAFFIC LANE,
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE
CITY OF LA QUINTA. AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES
AHEAD" SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH
FLASHING LIGHTS.
THE TRAFFIC SIGNAL AT JEFFERSON & AVE 50 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE. CONTRACTOR SHALL
ASSIST ANY PEDESTRIANS TRYING TO CROSS THE STREET.
C20CA) (RI)
RIGHT LANA'-
CLOSET
AHEAD
<D\
AHFAD /
W20.1
V /ROAD -
( WORK
\tAHFAIJ /
N /
s N Barricades, Inc.
D)852-TOPS 50
es Bros Construction
- Uri MA
Mike (760) 347-2291
rd By
Ron Fifield page 36
-. Pjrèit
11/19/19 5REV
THIS WORK WILL BE DONE
DURING NIGHTTIME HOURS
Pending
all Jefferson By Pass Sewer
vr
Wi-4 (LII 350' DOUBLE SIDED ULTRA LITE
PANEL (NARROW WIDTH) AVE 49
500' -
w:o-i
/\ / RAD \ /
W4-2
JEFFERSON ST
NO SCALE
CITY OF INDIO
AVE 50
W20-1
QT :
W5-1 350
IAL A&
CITY OF LA QUINTA
NOTES: 1. ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY
AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA AND/OR CITY OF INDIO REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME
IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10(12' TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BE1VIEEN THE EDGE OF
CUT AND THE NEAREST TRAFFIC LANE,
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES, ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE
CITY OF LA QUINTA. AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES
AHEAD SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH
FLASHING LIGHTS.
THE TRAFFIC SIGNAL AT JEFFERSON & AVE 50 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE. CONTRACTOR SHALL
ASSIST ANY PEDESTRIANS TRYING TO CROSS THE STREET
JESS ANNE AV
/
i -
THIS WORK WILL BE DONE DURING
DAYLIGHT HOURS UNLESS NIGHT IS
NECESSARY DUE TO SEWER FLOW
RsNd By DO PwftNwiw
Pending
..ORCHARD
for
Install Jefferson By Pass Sewer
Ri-i /
...- Jones Bros Construction Mike (760) 347-2291
Tmft Caft Dssi by PUod By Iaiiiimici' ''um PU
UIQIV Tops N Barricades, Inc. Ron Fifield page 57
E G P)cos BpW Limit DO Sh*Nw*w
(800)852-TOPS 50 11/19/19 6 REV
I
--
T
NEWPORT
BRIDGE PL _•_4_
FXISTM
C3O(C
uj
-. ('3D(C
R3-7 -+-.- - LANE\ mM,T CLOSED,' MUST. U'> -- - /
?
CITY OF INDIO
LAS PALMAS
DE LA QUINTA
JEFFERSON ST
6L
/
I WORK
AREA
T, alp
END
ROAD WORK
/ \
IjooROAD
L
900'
mm
CITY OF LA QUINTA
W20-1
ROAD\
THIS WORK WILL BE DONE
DURING NIGHT TIME HOURS
SHIELDS MOTORCOACH
COUNTRY CLUB
NOTES: 1 ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.TC.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY
AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LAQUINTAANDIOR CITY OF INDIO REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME
IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10'(1 2' TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF
CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALLAFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK,
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE
CITY OF LA QUINTA. AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES
AHEAD' SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH
FLASHING LIGHTS.
THE TRAFFIC SIGNAL AT JEFFERSON & AVE 48 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE. CONTRACTOR SHALL
ASSIST ANY PEDESTRIANS TRYING TO CROSS THE STREET.
A FLAGGER SHALL BE POSTED TO ASSIT SOUTHBOUND TRAFFIC WITH VISIBLITY ISSUES. FLAGGER SHALL WEAR A CLASS 3 ANSI GARMENT AND
SHALL BE EQUIPPED WITH A STOP & SLOW PADDLE.
G20 2
vV' 500'
C30 (CA)
/ I~--L-: mmm
W20.1
4uii 1L'q
j>
44
500' •' ZWU_ QUU
20( ) (LT) C'.O (CA) (LT)
C24577
OF, A~CIAVL*
uI
W20-1
•
500' J
G20-2
W20-1
ROAD
WORK
AHEAD ,
NEWPORT
BRIDGE P1
620-2
1~—m
CITY OF INDlO
LAS PALMAS
DE LA QUINTA
CITY OF LA QUINTA
i:- •Y
C24577 J:
500'
It c. I
/
cU
K
-. . .
.4."
L
NO SCALE
Pending
Tmftcwmmm fw
Install Jefferson By Pass Sewer
P" cmvww cow
Jones Bros Construction Mike (760) 347-2291
TDSIby Pmp.idBy THIS WORK WILL BE DONE DURING
Tops N Barricades, Inc. Ron Fifield page 36 DAYLIGHT HOURS UNLESS NIGHT IS
Phm LnI Di. NECESSARY DUE TO SEWER FLOW (600)652-TOPS 50 11113/19 8 REV
NOTES: 1. ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY
AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTAAND/OR CITY OF INDI0 REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS)AND MAINTAIN SAME
IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10(12' TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF
CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE
CITY OF LA QUINTA. AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES
AHEAD SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH
FLASHING LIGHTS.
WHEN WORK IS DONE AT NIGHT, THE TRAFFIC SIGNAL AT JEFFERSON & AVE 48 SHALL BE PLACED IN RED FLASH.
WHEN WORK IS DONE DURING DAYTIME OFF PEAK TRAFFIC HOURS, THE SIGNALS SHALL REMAIN IN OPERATION.
C-,
RI-1
EQ\Ø
z
W20-1
,4 Cl) W Cl)
W LU
EXFSTING
-z
WE
NO SCALE
END
ROAD WORK
W20.1 JEFFERSON ST 020-2
500
DOUBLE SIDED ULTRA LITE DOUBLE SIDED ULTRA LITE
PANEL (NARROW WIDTH)PANEL (NARROW WIDTH) .......-
[
Rl-
-
EENOTE
46 - ,-
I-
_
i AREA
500' 300'1 \ 0 CA ti
WI-4JLT) -
31
( C24577 1
' ?L_J J'
/ z../Zo 1 2- ,
THIS WORK WILL BE DONE DURING
DAYLIGHT HOURS UNLESS NIGHT IS
NECESSARY DUE TO SEWER FLOW
ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C.D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED, ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10'(12- TYP.) TRAFFIC LANE WIDTH AT ALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE CITY OF LA QUINTA.
AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES ("STEEL PLATES AHEAD" SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL,
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH FLASHING LIGHTS.
TRAFFIC SIGNAL AT JEFFERSON & AVE 50 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE,
Pending
Trc Cmw pm 1v
I nstall Jefferson By Pass Sewer
Pirn C*
Jones Bros Construction Mike (760) 347-2291
Tmffic Corbo Dedr by Pipsid By B.,.d on WATCH pg
Tops N Barricades, Inc. Ron Fiuield page 57
— L* DO _
(800)852-TOPS 50 11/19/19 9 REV
IS
NO SCALE
W20-1
C-, WC/)
RI-I W LU
MOP RI-I
Et a,
EX ST G
x I
UILL
500' 350' 350'
N
RI -11 600'
RI-1 I w2O\5 (IT)
OAOC WORK
> Q * EXO
wo-i JEFFERSON ST
END
ROAD WORK]
C30 CA)
5001 1 • SEE NOTE J14 (LI) w54
W1-4 (RI)
300'
jW0R
AREA
JI
$
r /1
/ DOUKLE SIDED L ISA LITE
C3CA) h PANEL )NARA I)TH)
-
---U
LaIj
/ CNARROWy
047
/
350' 350'
AVE 50
520-2
END
ROADWORK
THIS WORK WILL BE DONE DURING
DAYLIGHT HOURS UNLESS NIGHT IS
NECESSARY DUE TO SEWER FLOW
ALL TRAFFIC CONTROL DEVICES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH REVISION 4 OF THE 2014 CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA M.U.T.C. D.)
TRAFFIC CONTROL SHOWN HEREIN IS THE MINIMUM REQUIRED. ADDITIONAL TRAFFIC CONTROL MAY BE REQUIRED TO FACILITATE PUBLIC SAFETY AND TRAFFIC FLOW IF DEEMED NECESSARY BY CITY OF LA QUINTA REPRESENTATIVE.
THROUGHOUT EACH WORK PERIOD, CONTRACTOR SHALL INSPECT TRAFFIC CONTROL (SIGNS, BARRICADES AND DELINEATORS) AND MAINTAIN SAME IN ACCORDANCE WITH TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL MAINTAIN A MINIMUM 10'(1Z TYP.) TRAFFIC LANE WIDTH ATALL TIMES. THERE SHALL BE A MINIMUM 2' BETWEEN THE EDGE OF CUT AND THE NEAREST TRAFFIC LANE.
ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. ALL AFFECTED RESIDENTS SHALL BE NOTIFIED IN ADVANCE OF THE WORK.
THIS TRAFFIC CONTROL SHALL BE IN PLACE DURING WORK HOURS ONLY. THE WORK HOURS SHALL BE DETERMINED BY THE CONTRACTOR AND THE CITY OF LA QUINTA.
AT THE END OF WORK HOURS, THE TRENCH SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC PLATES (STEEL PLATES AHEAD SIGNS ON BARRICADES WITH FLASHING LIGHTS SHALL BE POSTED), THE ROAD SHALL BE CLEAR
OF DEBRIS AND TRAFFIC RETURNED TO NORMAL.
ALL TRAFFIC CONTROL DEVICES USED DURING HOURS OF DARKNESS SHALL BE RETRO-REFLECTIVE AND ALL BARRICADES SHALL BE EQUIPPED WITH FLASHING LIGHTS.
TRAFFIC SIGNAL AT JEFFERSON & AVE 50 SHALL BE PLACED IN RED FLASH WHILE THIS TRAFFIC CONTROL IS IN PLACE.
Pending
Install Jefferson By Pass Sewer
Jones Bros Construction Mike (760) 347-2291
Thift Ca" DWp by By Dow cI4 Pg
Tops N Barricades, Inc. Ron Fifield page 57
(800)852-TOPS 50 11/19/19 10 REV