06-1982 (AR) Title 24TITLE 24 REPORT
Title 24 Report for:
Mr. & Mrs ZEHNDER
54 979 Laurel Valley
L a Quinta, CA 92253
Project Designer:
Construction Consultants Inc.
9 Saturn Circle
Rancho Mirage, CA 92270
760.832.5259
Report Prepared By:
SLO
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, CA 92247
(760) 485-8927
Job Number:
Ig040506
Date:
7/25/2006
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
C1
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.2 by EnergySoft Job Number: Ig040506 User Number: 5732
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
1
2
3
9
11
EnergyPro 4.2 by EnergySoft Job Number: Ig040506 User Number: 5732
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
_Mt_&_Mrs_ZE_H ni=R
Addition
New 09-A5
Additinn
7/25/2006
Project Title
Existing 09-A5
Zone 2
Existing 28-A4
Date
_5�97_cLLaureI Valley I a -Quints
Zone 2
Zone 2
Existing 09-A5
Zone 2
Project Address
Zone 2
Zone 2
Zone 2
Removed 09-A5
Removed 09-A5
Removed 09-A5
Zone 2
Zone 2
ZoIle 2
Building Permit #
Santi.a.� cans
r R o
Existing_ 09-A5
Zone 2
( 760) 485-8927
Zone 1
Documeniation Author
Zone 1
Existing 09-A5
Telephone
plan Check/Date
_FneravPro
Compliff6ce Method
Existing 09-A5
Znne 1
15
Climate Zone
Zone 1
Field Check/Date
TDV
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.02
1.63
0.39
Space Cooling
56.49
55.38
1.11
Fans
8.45
8.25
0.19
Domestic Hot Water
8.36
8.36
0.00
Pumps
0.00
0.00
0.00
Totals
75.32
73.63
1.69
Percent better than Standard:
2.2%
Building Type: Q Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
[X-1 Existing + Add/Alt
(S)180 deg
Natural Gas
Area: 564 ft 2 Avg. U: 0.46
Ratio: 18.4% Avg. SHGC: 0.34
Total Conditioned Floor Area:
Existing Floor Area:
Raised Floor Area:
Slab on Grade Area:
Average Ceiling Height:
Number of Dwelling Units:
Number of Stories:
BUILDING ZONE INFORMATION # of
Zone Name Floor Area Volume Units Zone Type
.H_VAC_SystPm 7nne 9 ? 568 X505 -0._51_ Conditioned
JiVAC_System Zone 1 1,501 15,010 049 Conditioned
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
.RO.O.t_ Mthod_ 72 _0025- X31 R-0 0_ 0_ 1
-Wall- 36_ 00511 R-19 R-4 .5_ -2709.0
Wall Wnod- 40 0058.019 R-4.5_090
Wall_ Wond- 36_ _00.5.8.019 _R-4 5_ 9.09.0
Wall- Wood_ 55 005& 019 _R-4.5 _270_ 9.0
Wall_ MDd_ 61 0_0.58_ R-19 R-4 5 225 9.0
D.O.OL- Mone 24 0.500_ -None- R_0 0 22ri 90
Wall_ Wand- 5 0.058.0-19 R--4_5_ -270_-90
Wall_ Wood 95 00.58 019 _R-4 5 -180 9
Wall_ Wood_ 115 00.5& -R-1.9_ _R-4.5 AZO_ 90
Wall_ Mod 48.0-0.58.0-19 R-4 5 09.0
Wall- Mod- _____168_ _0_058 019 _R-5_ _270 A
Wall_ Wnod_ ZQ _0058.019 _R--4.5_ _09.0
Wall_ Wood- 10 00.58 019 _RA5 270 9.0
Wal_ Wood 4.5 0_058_ X19 R-4.5 Q-9.0
-Nall_ Word_ 10 0058_ -8-19.0' 5 9.0_ 9.0
Wall_ Wood 76 0.058. R-19 R-4,15 _090
Wall- Wnnd_ 328_ _0058 R-19_ _R=4 5 x.0_ 90
.Ronti_ Wnnd x.,5.010025.0.38. R-0.0_ _D_ 18
Wall_ Wand ____25_ _US& -R-19_ _R4.5 J$.Q 90
Wall_ Wood_ 181 -0-07A X19 R-0..0_ 180 _80
Door clone_ 21 00.00 None_ _R-0_0 180 9
Wall_ 1L1Caad_ 115_ _0_0.74 R_19 R-0.0 9.0 _90
Wall_ Wood- X32 0074 019 R-00_ 180 9Il
Wall- V_Vnnd 41 00.58.0=19_ R--4 5_ x.8.090
Thermostat
Type
-Sethnck-
Setback
3,070 ft2
3,020 ft2
0 ft2
3,216 ft2
10.0 ft
1.00
1
Vent
Hgt. Area
-2 n/a
_2 _n1a
Gains Condition
Y / N Status JA IV Reference Location / Comments
❑Existing 01-A18 Addiflon
❑New 09-A5 Addition
New 09-A5
Addition
New 09-A5
Additinn
Existing_ 09-A5
Zone 2
Existing 09-A5
Zone 2
Existing 28-A4
Zone 2
Fxicting 09-A5
Fxicting 09-A5
Zone 2
Zone 2
Existing 09-A5
Zone 2
Fxicting 09-A5
Existing 09-A5
Fxicting 09-A5
Zone 2
Zone 2
Zone 2
Removed 09-A5
Removed 09-A5
Removed 09-A5
Zone 2
Zone 2
ZoIle 2
Fxicting 09-A5
Zone 2
Existing_ 09-A5
Zone 2
New 01-A18
Zone 1
Existing 09-A5
Zone 1
Existing 09-A5
Zone 1
ExMng 28-A4
Existing 09-A5
Zone 1
Zone 1
Existing 09-A5
Znne 1
Fxicting 09-A5
Zone 1
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: IQ040506 Paoe:3 of 12 1
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
_Mr_._& MrsZEH.N.DER
3,070
ft2
Existing Floor Area:
7/25/2006
Project Title
Raised Floor Area:
0
ft2
Date
_54 M -Laurel ValleyLa
--�-
Quinta
Average Ceiling Height:
10.0
ft
Project Address
1.00
Building Permit #
SaatiaCC��.QLope7- MPIMRo'
(760) 485-8927
Plan Check/Date
DocumenTation Author
Telephone
EneravPro
15
Field Check/Date
Compli'3r3ce Method
Climate Zone
TDV
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.02
1.63
0.39
Space Cooling
56.49
55.38
1.11
Fans'
8.45
8.25
0.19
Domestic Hot Water
8.36
8.36
0.00
Pumps
0.00
0.00
0.00
Totals
75.32
73.63
1.69
Percent better than Standard:
2.2%
Building Type: (X-] Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
Existing + Add/Alt
(S) 180 deg
Natural Gas
Area: 564 ft 2 Avg. U: 0.46
Ratio: 18.4% Avg. SHGC: 0.34
BUILDING ZONE INFORMATION
Zone Name Floor Area Volume
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Wall_ W010d_ 192 _0.058_ R-19 R_5 270 9.0
Wales 15 _0-058. _R-19 -R=4 5_ -0_-90
Wall_ .Wood_ X46 -0058 R_19 R -4.5_-2Z0_ 90
Wall- Wood- 40 _0-058 -19_ _2_4-5_ -315 _90
Wall_ Wond- 58_ _0.05B_ R-19- _R=4-5_ -0 An
Wall_ Wood- 43 _0.058_ R-19 _EZ4 5 -2Z0 9
1N.all- Mod- 286 -D-M&-R--19- X4._5. 90.90
Total Conditioned Floor Area:
3,070
ft2
Existing Floor Area:
3,020
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
3,216
ft2
Average Ceiling Height:
10.0
ft
Number of Dwelling Units:
1.00
Number of Stories: 1
# of Thermostat Vent
Units Zone Type Type Hgt. Area
Gains Condition
Y / N Status JA IV Reference Location / Comments
® ❑Existing 09-A5 Zone 1
® ❑Existing 09-A5 Zone 1
® ❑Existing 09-A5 Zone 1
®❑Existing 09-A5 ZOIle 1
® ❑Existing 09-A5 Zone 1
® ❑Existing 0.9-A5 Zone 1
❑ ❑Existing 9 AS Zona 1
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
EnergyPro 4.2 by EnergySoft . User Number: 5732 Job Number: Ig040506 Page:4 of 12 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Mr. & Mrs ZEHNDER 7/25/2006
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazinq Type Comments
1 Window I eft 440 0 570 N11-= SDG _270_ 90_ New PPG-SOLARBAN 8 (3) Bronze _.Addition
Window
Hgt. Wd.
2
Window
Rear (N)
49.5
0.570 NI -1 0_31 COG 0 90 New PPG SOLARBAN 60 (3) Bronze
Addition
3
Window
Right (E)
44.0
0.570 NI -1 0_31 COG 90 90 New PPG SOLARBAN 60 U Bronze
Addition
4
Window
Left (YV)
40.0
0.390 NFRC 0_31 NFRC 270 90 Existing_Milgard Classic LoE170C1r Vinyl
Zone 2
5
Window
Rear (N)
80.0
0.390 NFRC 0_31 NFRC 0 90 Existing Milgard Classic LoE170C1r Vinyl
Zone 2
6
Window
Left (W)
15.0
0.570 NI -1 0_31 COG 270 90 RemoveclPPG SOLARBAN 60 (3) Bronze
Zone 2
Z
Window
Rear (N)
54.0
0.570 NI -1 0.31 COG 0 90 RemovedPPG SOLARBAN 60 (3) Bronze
Zone 2
8
Window
Right (E)
15.0
0.570 NI -1 0.31 COG 90 90 RemovedPPG SOLARBAN 60 (3) Bronze
Zone 2
6
Window
Rear (N)
64.0
0.390 NFRC 0.31 NFRC 0 90 Existing Milgard Classic LoE170CIr Vinyl
Zone 2
10
Window
Right (EE)
35.0
0.390 NFRC 0.31 NFRC 90 90 Existing Milgard Classic LoE170CIr Vinyl
Zone 2
11
Window
Right (E)
25.0
0.390 NFRC 0_31 NFRC 90 90 Existing Milgard Classic LoE170CIr Vinyl
Zone 2
12
Window
Front (S)
24.0
0.650 NFRC 0_48 NFRC 180 90 Existing WECK, GLASS BLOCK 8x8x4
Zone 1
13
14
1L)(lndow Left (W)
Window Left (W)
94.0
4.0
0550_NFRC -DAB NFRC -27_Q-9.QExi5ting 1p(IECK GLASS BLOCK 8x8x4
0.390 NFRC 0_31 NFRC 270 90 Existing Milgard Classic LoE170C1r Vinyl
Zone 1
Zone 1
15
Window
Left (W)
7.0
0.390 NFRC 0_31 NFRC 270 90 Existing Milgard Classic LoE170C1r Vinyl
Zone 1
16
Window
Left (W)
7.0
. 0.390 NFRC 0_31 NFRC 270 90 Existing Milgard Classic LoE170C1r Vinyl
Zone 1
17
Window
Left (NW)
30.0
0.390 NFRC 0_31 NFRC: 315 90 Existing Milgard Classic LoE170C1r Vinyl
Zone 1
18
Window'
Left (W)
12.0
0.650 NFRC 0_48 NFRC 270 90 Existing WECK, GLASS BLOCK 8x8x4
Zone 1
12
Window
Right (F)
30.0
0.390 NFRC 0.31 NFRC 90 90 Existing Milgard Classic LoE170C1r Vinyl
Zone 1
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
4.0
INTERIOR AND EXTERIOR SHADING
# Exterior Shade Type SHGC
Window
Hgt. Wd.
Len.
Overhang
Hgt. LExt.
REA
Left Fin
Dist. Len. Hgt.
1
Bug Screen
0.76
5.5
4.0
17.0
0.1
1.5
0.0
0.0 0.0 0
2
Bug Screen
0.76
5.5
9.0
1.5
0.1
4.0
4.0
3.50 28 0_98 0
3
Bug Screen
0.76
5.5
8.0
15.0
0.1
10.0
10.0
0.1 13.6 0
4
Bug Screen
0.76
6.7
6.0
1.
0.
4.0
4.0
Condition
5
Bug Screen
0.76
8.0
10.0
9.5
0.1
1.0
1.0
26-A1
6
Bug Screen
0.76
6.0
2.5
15,
0.1
10.0
10.0
0.0 0.0
7
Bug Screen
0.76
5.5
9.0
1.5
0.1
4.0
4.0
Zone 1
8
Bug Screen
0.76
6.0
2.5
15.0
0.1
10.0
10.0
0.1 13.6 0
9
Bug Screen
0.76
8.0
8.0
9.5
0.1
1.0
1.0
10
Bug Screen
0.76
5.0
7.0
1.5
0.1
4.0
4.0
11
Bug Screen
0.76
5.0
5.0
1.5
0.1
4.0
4.0
12
Bug Screen
0.76
6.0
4.0
1.5
0.1
4.0
4.0
13
Bug Screen
0.76
6.0
4.0
1.5
0.1
4.0
4.0
14
Bug Screen
0.76
2.0
2.0
1.5
0.1
4.0
4.0
15
Bug Screen
0.76
3.5
2.0
1.5
0.1
4.0
4.0
16
Bug Screen
0.76
3.5
2.0
1.5
0.1
4.0
4.0
17
Bug Screen
0.76
6.0
5.0
3.5
0.1
4.0
4.0
18
Bug Screen
0.76
6.0
2.0
9.0
0.1
1.0
1.0
19
Bug Screen
0.76
5.0
6.0
1.5
0.1
4.0
4.0
THERMAL MASS FOR HIGH MASS DESIGN
Riaht Fin
Dist.
Len.
Hgt.
0.1
15.5
0
0.0
0.0
0
Status
Comments
Concrete, He�eight
196
4.00 28 0.98 0
26-A1
4.0
15.5
-4
0.0
0.0
0
i EnergyPro 4.2 by EnergySoft . User Number: 5732 Job Number: Ig040506 Pace:5 of 12 1
Area Thick. Heat Inside
Condition
Location/
Type
(so
(in.) Cap. Cond. R -Val.
JA IV Reference
Status
Comments
Concrete, He�eight
196
4.00 28 0.98 0
26-A1
New
Addition / Slab on Grade
Concrete, Heavyweight
659
3.50 28 0.98 2
26-A1
New
Zone 2 /Slab on Grade
Concrete, Heavyweight
860
3.50 28 0_98 0
26-A1
New
Zone 2 / Slab on Grade
Concrete, He�eight
975
3.50 28 0.98 2
26-A1
New
Zone 1 / Slab on Grade
Concrete, Heavyweight
526
3.50 28 0.98 0
26-A1
New
Zone 1 / Slab on Grade
PERIMETER LOSSES
Insulation
Condition
Location/
Type Length
R -Val. Location
JA IV Reference
Status
Comments
Slab Perimeter
42
None No Insulation
26-A1
New
Addition
Slab Perimeter
76
None No Insulation
26-A1
New
Zone 2
Slab Perimeter
61
None No Insulation
26-A1
New
Zone 2
Slab Perimeter
108
None No Insulation
26-A1
New
Zone 1
Slab Perimeter
36
None No Insulation
26-A1
New '
Zone 1
i EnergyPro 4.2 by EnergySoft . User Number: 5732 Job Number: Ig040506 Pace:5 of 12 1
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Mr. & Mrs ZEHNDER 7/25/2006
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
20 -Wj do.w Right (E) —.0.0_ X3.9.0 NF_RG_-D-31 NERC 90 —90_ Existing NWaard Clasc_ic I OF170Clr Vinyl zone 1
21 Window Right (E) 4.0 0.390 NFRC 0_31 NFRC 90 90 Existing Milgard Classic LoE170CIr Vinyl Zone 1
22 Window Right (E) 30.0 0.390 NFRC 0_31 NFRC 90 90 Existing Milgard Classic LoE170C1r Vinyl Zone 1
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LEA
REA Dist. Len. Hgt. Dist. Len. Hgt.
20
Bug Screen
0.76
4.0
2.5
1.5
0.1
4.0
4.0
21
Bug Screen
0.76
2.0
2.0
1.5
0.1
4.0
4.0
22
Bug Screen
0.76
5.0
6.0
1.5
0.1
4.0
4.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
Run Initiation Time: 07/25/06 10:56:09 Run Code: 1153850169
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig040506 Page:6 of 12
PERIMETER LOSSES
Insulation
Condition
Location/
Type Length R -Val.
Location
JA IV Reference Status
Comments
Run Initiation Time: 07/25/06 10:56:09 Run Code: 1153850169
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig040506 Page:6 of 12
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
Mr. & Mrs ZEHNDER
Project Title
Date
7/25/2006
HVAC SYSTEMS
Ratedl
Tank
Energy
Standbyl Tank Insul.
Water Heater
# in Input
Cap.
Heating
Minimum
Cooling
Minimum
Condition
Thermostat
Location
Type
Eff
Type
Eff
Status
Type
HVAC System Zone 2
Central Furnace
80% AFUE
Split Air Conditioner
12.5 SEER
Existing
Setback
HVAC System Zone 1
Central Furnace
80% AFUE
Split Air Conditioner
12.2 SEER
New
Setback
HVAC DISTRIBUTION
Location
Duct Duct Condition Ducts
Coolino Location R -Value Status Tested?
HVAC System Zone 2 Ducted Ducted Attic 4.2 Existing Yes
HVAC System Zone 1 Ducted Ducted Attic 4.2 New Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS
Ratedl
Tank
Energy
Standbyl Tank Insul.
Water Heater
# in Input
Cap.
Condition Factor
Loss R -Value
System Name Type Distribution
Syst. (Btu/hr)
(gal)
Status or RE 1
(%) Ext.
Bradford -White Corp. Small Gas No Pipe Insulation
1 70,000
75
New 0.59
n/a n/a
-PDX275T "
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name
Documentation Author
Name: SLO
Title/Firm: Construction Consultants Inc. Title/Firm: Santiago Lopez-Ocampo
Address: 9 Saturn Circle Address: P.O. Box 1018
Rancho Mirage, CA 92270 La Quinta, CA 92247
Telephone: 760.832.5259 Telephone: (760) 485-8927
Li
- m<_
(si ure) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Tplpnhnnp-
(signature) (date)
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Mr. & Mrs ZEHNDER 7/25/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
aaencv determines the adeauacv of the justification, and may refect a buildina or design that otherwise complies based on the
adequacy of the special justification and documentation submitted. Plan Field
HIGH MASS Design - Verify Thermal Mass:
196 sqft Exposed Slab Floor, 4.00" thick at Addition
HIGH MASS Design - Verify Thermal Mass:
659 sqft Covered Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design - Verify Thermal Mass:
860 sqft Exposed Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design - Verify Thermal Mass:
975 sqft Covered Slab Floor, 3.50" thick at Zone 1
HIGH MASS Design - Verify Thermal Mass:
526 sqft Exposed Slab Floor, 3.50" thick at Zone 1
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approvea nerca proviaer using Lr -L, approvea testing anaior venncation meinoas ano must oe reportea on ine t r -4K
installation certificate.
Plan
Field
The HVAC System "HVAC System Zone 2", incorporates HERS verified Duct Leakage. Target leakage is calculated and documented
on the CF -4R.
The HVAC System "HVAC System Zone 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented
on the CF -4R.
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig040506 Page:8 of 12 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the
permit application documentation.
NIA
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
❑
❑
§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
❑
❑
❑
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
❑
❑
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
❑
❑
b. outside air intake with damper and control, flue damper and control
❑
❑
❑
2. No continuous burning gas pilot lights allowed.
❑
❑
❑
§ 150(0: Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
§ 118: Insulation specked or installed meets insulation installation quality standards. Indicate type and include
❑
0
El
Form:
❑
❑
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
a
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
❑
❑X
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B,
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: lg04O5O6
Page:9 of 12
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers. ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
❑D
❑ ❑
X
FOR
❑E
a. At least 36" of pipe between filter and heater for future solar heating.
❑
❑
❑
b. Cover for outdoor pools or outdoor spas.
❑
❑
❑
3. Pool system has directional inlets and a circulation pump time switch.
❑
❑
❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑
❑
❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ ❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 118 (i): Cool Roof material meets specified criteria
❑
❑
❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ x❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ ❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
be high luminaires less than 70 ft) OR by dimmer OR
❑ ❑ ❑
shall efficacy (except closets are controlled a switch are
controlled by an occupant sensor that complies with Section fl 9(d) that does not tum on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑x ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ Fil ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/Water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig040506
Page: 10 of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Mr. & Mrs ZEHNDER 7/25/2006
SYSTEM NAME FLOOR AREA
HVAC System Zone 2 1,568
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRIi
26.0 of 68.8 of 68.8 of
Outside Air 0
0 cfm
Supply Fan
2075 cfm
68.8 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
1,121
20,289
2,251
786
22,303
0
3,203
2,579
0
0
0
0
0
0
0
0
0
3,203
2,579
26,6951 2,2511
27,461
York H4DH060/P4HUC20LO64 U&H 43,976 8,326 64,000
Total Adjusted System Output 43,976 8,326 64,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 ami
Heating Coil
97.8 of
�% Return Air Ducts 4
Supply Air Ducts
96.6 of
ROOMS
70.0 of
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.6OF 79.5/65.5OF 79.5/65.6OF 59.5/58.4OF
Supply Air Ducts
Outside Air 0
0 cfm Supply Fan Cooling Coil 61.0 / 58.9 of
2075 cfm 50.4% R.H. ROOMS
79.5/65.5 of 78.0 / 65.1 of
Return Air Ducts I
EnergyPro 4.2 by EnergySoft User Number. 5732 Job Number: lg04O5O6 Page: 11 of 12 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Mr. & Mrs ZEHNDER 7/25/2006
SYSTEM NAME FLOOR AREA
HVAC System Zone 1 1 501
SYSTEM LOAD
EATING SYSTEM
26.0 of
Outside Air
0 cfm
67.9 of
A-7 o OG
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
CFM
I Sensible
433
17,612
2,188
252
19,268
0
2,116
1,779
0
0
0
0
0
0
0
744
-744
2,1161
1,779
22 588 2 188 22,0821
York H4DH048/P4HUB16L064 U&H 37,516 0 64,000
Total Adjusted System Output 37,516 0 64,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
earn Temperatures at Time of Heating Peak)
143.1 of 144.0 of
Heating Coil
Supply Air Ducts
Supply Fan 141.9 of
800 cfm ROOMS
70.0 of
Return Air Ducts I
:DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
11.0/77.6OF 80.5/56.5OF 36.4/34.5OF 37.3/35.0OF
Outside Air .
Supply Air Ducts
0 cfm Cooling Coil Supply Fan 39.8 / 36.5 of
800 cfm 21.4% R.H. ROOMS
80.5/56.5 of 78.0 / 55.5 of
Return Air Ducts I
EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig040506 Page: 12 of 12