Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-0936 (AR) Title 24
TITLE 24 REPORT k r Title 24 Report for: ' Young Residence 55455 Laural Valley La Quinta, CA 0 Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DArE 10 ft b 01 BY Report Prepared By.� Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, CA 92211 (760) 345-1352_ OCT 0 "'-j i vt Job Number: Date: „ . 10/1 /2009 !� ���1� The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 6 HVAC System Heating and Cooling Loads Summary 8 Room Load Summary g n I _ EnergyPro 4.4 by EnergySoft Job Number: d User Number: 2655 • I Certificate Of Compliance :Residential (Part 1 of 3) CF -1 R Young- esidence Single Family ❑ Addition Total Conditioned Floor Area: 01A /20QA Project Title Wall_ Wood- 91 ❑ Multi Family n Existing + Add/Alt Date _5545.51 aucal_V_alley La-Qui.nta Building Front Orientation: (E) 90 deg Raised Floor Area: Project Address ft2 Fuel Type: J2oor None_ 2.0_ Building Permit # 1ns.u_ o.rm.,lnc_ 2,044 ft2 (760)-345-1352 Wall_ Wood_ 120_ Documentation Author Average Ceiling Height: 8.9 Telephone Plan Check/Date _Ene.r_q -P_r_o Avg. U: 0.80 Number of Dwelling Units: C/-CJ.imate_Zone-tS 0 Field Check/Date Compliltice Method SHGC: 0.70 Number of Stories: Climate Zone TDV Standard Proposed Compliance Zone Name Aptu/sf-yr) Design Design Margin Area Space Heating 3.42 3.01 0.41 2 Space Cooling 121.71 99.89 21.82 Fans 16.83 13.82 3.01 Domestic Hot Water 12.78 12.78 0.00 Pumps 0.00 0.00 0.00 Totals 154.74 129.50 25.24 than Standard: Building Type:] Single Family ❑ Addition Total Conditioned Floor Area: 2,044 ft2 Wall_ Wood- 91 ❑ Multi Family n Existing + Add/Alt Existing Floor Area: 1,910 ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: 0 ft2 Fuel Type: J2oor None_ 2.0_ Natural Gas Slab on Grade Area: 2,044 ft2 Fenestration: Wall_ Wood_ 120_ -0.1.02 _R_i3_ J3_0_0_ ___27_0____9.0 Average Ceiling Height: 8.9 ft Area: 323 ft 2 Avg. U: 0.80 Number of Dwelling Units: 1.00 0 Ratio: 15.8% Avg. SHGC: 0.70 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .LLving_Zooe U4_4 18262 1_00_ Conditioned- -Setback_ 2 -n/a OPAQUE SURFACES Insulation Act. Addition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall_ Wood- 91 _0-07-4 Jt1_9_ __EL -0_0_ -27.0_-90 Addition -Wall- Wood_ 91 _0...0.7 _R19 _RD_0_ 0__9.0 Existing -Wing .Existing_Living _Roof- Wood_ ____134_ _0-025 _R_38_ __R_0_D_ 1.8.0_ 0 Wall_ Wood- 238_ _0 _02 _B,3_ _R=0.0_ 9.0__9.0 Existing I Ova J2oor None_ 2.0_ _0.5.0D_ -None_ J1O_0_ -90--90 -Existing-Living Wall_ Wood --180 _0..102 -R_t8_ _i_0.0 1.80_ 9.0 Wall_ Wood_ 120_ -0.1.02 _R_i3_ J3_0_0_ ___27_0____9.0 Wall_ Wood- _____10.0_ _0-102. 0_i3_ _13-0A -27.0_ 9.0 Wall Wood_ .QO_ 0-1.02 _R_]_3_ _R_O..D_ _0 90. J3oof_ Wood_ 1_,910_ _0..049 .R--1.9_0_0_ 9D_ 0 Gains Condition Y / N Status JA IV Reference Location / Comments Nevi _09--A5 Addition N.ew _0.9=A5 Addition New _0_1LA18 Addition Existing- Existing_ _09_A3 .28-A4 Existing -Wing .Existing_Living Existing_ _0.9=A3 Existing -Living Existing_ _09_A3 Existing I Ova Removed- _09--A3 -Existing-Living Existing_ _0.9=A3 -Existing-Living Existing- _OiA4 Existing -Living EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Paae:3 of 9 1 Certificate Of' Compliance : Residential (Part 2 of 3) CF -1 R Young Residence 10/1/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area LI -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments _1- 2 Window Rear_(W)- _23.2. Window Right (N) 27.4 -0.190-1-1-6-A-020 0.70 -J16.3 0.790 116-A 0_70 116-B _2.7-0_ 0 _90- Np-w Do.ubie_MetaLC1ear 90 New Double Metal Clear -Addition Addition 3 Window Front (E)_ 20.0 0.790 116-A 0_70 116=B 90 90 Existing_ Double Metal Clear Existing Living 4 Window Front (E) 12.0 0.790 116-A 0_70 116-B 90 90 Existing -Double Metal Clear Existing Living 5 Window Left (S)_ 20.0 0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear Existing Living 6 Window Left (S) 4.0 0.790 116-A 0.70 116-B 180 90 Existina_Double Metal Clear Existing Livin L 8 Wipdow Lefft_(_S _ Window Rear (W) 1610 66.8 9.790 -A 0.70 0.790 116-A 0_70 116_6 116-B 1$0. 270 90 E)islirng__Q-owb.Le Mortal Gear 90 RemovedDouble Metal Clear Existir _Living Existing Living 3 10 11 Win ow Rear_(. Window Rear (W) Window Rear (W)- 33.49-.799 20.0 26.7 116-A 0.70 0.790 116-A 0.7 0.790 116-A 0_70 116-B 11 - 116-B 270 27.0 270 90 Existing Double Metal Clear 94 Exieti tng_Double Metal wear 90 Existing Double Metal Clear -Existing-Living Exi in Living Existing Living 12 Window Right _(N) 26.7 0.790 116-A 0_70 116-B 0 90 Existing_ Double Metal Clear Existing Living 3 14 Window Bight_(N.)_ Window Right (N) -4Q0- 40.0 _0790 116_A.0.20 0.790 116-A 0_70 -J16=8 116-B 0_ 0 90. B.emgvedQouble_MeiaLClear 90 Existing -Double Metal Clear _Exis1iMLiying Existing Living 15 Window Right (N) 40.0 0.790 116=A 0_70 116-B 0 90 RemovedDouble Metal Clear Existing Living 16 Window Right (N)_ 26.7 0.790 116-A 0_70 116-B 0 90 Existing_ Double Metal Clear Existing Living 17 Window Right (N) 26.7 0.870 NFRC 0_70 _NFRC. 0 90 New Double Mtl Uncoated Default Existing Livin 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 33 None No Insulation 26-A1 Window Addition Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.0 3.9 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 6.0 4.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 10.0 2.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 2. --0.1 2. 2� 5 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 2.0 2.0 2.0 _0..1 2_0 2.0 7 Bug Screen 0.76 2.0 8.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.8 10.0 2.0 0.1 2.0 2.0 9 Bug Screen _ 0.76 6.8 5.0 6.0 0.1 6.0 6.0 10 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.8 4.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 6.8 2.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.8 3.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 6.8 4.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 6.7 4.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 33 None No Insulation 26-A1 New Addition Slab Perimeter 90 None No Insulation 26-A1 Existing Existing Living Run Initiation Time: 10/01/09 16:56:38 Run Code: 1254441398 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page 4 of 9 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R Young Residence 10/1/2009 Project Title Date HVAC SYSTEMS Heating Minimum -Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living Zone Central Furnace 80% AFUE Slit Air Conditioner 12.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Living Zone Ducted Ducted Attic 4.2_ Existing No 1 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. Btu/hr (gal Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length U Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Address: Telephone: Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 77-810 Las Montanas Road, Suite 201 Palm Desert, CA 92211 Telephon (760) 345-1352At (signa e � It-` Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -tactor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑R ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -tactor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El a El Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑x ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ' ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water, Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑x ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ o ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirety in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:6 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ LnI ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ 0 ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ Q ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Root material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms be high efficacy luminaires (except closets less than 70 ftj OR are controlled by a dimmer switch OR are controlled El ❑X El by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:7 of 9 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Young Residence 10/1/2009 SYSTEM NAME FLOOR AREA Living Zone _ _ 2,044 Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sqft) 34.7 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 28.4 Total Output (sgft/Ton) 422.9 Air System CFM per System 1,500 Airflow (cfm) 1,500 Airflow (cfm/sgft) 0.73 Airflow (cfmrron) 310.3 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above gi JEATING SYSTEM 26.0 OF Outside Air 0 cfm 67.3 of 11.0 / 77.6 of 3111� Outside Air 0 cfm 82.4/62.4 of at ARI conditions 67.3 of Supply Fan 1500 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 48,746 3,168 38,429 Exist 49,668 0 71,000 Total Adjusted System Output 49,668 0 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Tem 67.3°F1© 111.80F • Rim_ Heating Coil K Return Air Ducts 4 82.4/62.4OF 82.4/62.4OF M 51.3/49.7OF --(P Supply Fan 1500 cfm Cooling Coil h Return Air Ducts 11 Supply Air Ducts 109.1 of ROOMS 70.0 of Supply Air Ducts 55.6/51 . 5 of 37.0% R.H. ROOMS 78.0/60.9OF EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Pape:8 of 9 1 ROOM LOAD SUMMARY PROJECT NAME Young Residence DATE 10/1/2009 SYSTEM NAME Living Zone FLOOR AREA 2,044 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 262 6,231 903 262 6,231 903 96 3,998 Existing Living Existing Living 1 1,199 28,537 2,265 1,199 28,537 2,265 622 25,873 PAGE TOTAL L. 1,461 34,769 3,168718 TOTAL 1,461 34,769 3,168 29,871 718 29,871 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:9 of 9