Loading...
10-1383 (SFD) Title 24' BUILDING ENERGY ANALYSIS REPORT PROJECT: ADAMS RESIDENCE 77153 CASA DEL SOL LA QUI NTA, CA 92253 Project Designer:. GLS Architecture Group Inc. 74491 Joni Dr. Suite # 9 Palm Desert, Ca 92260 760 34.0.35.28 ,Report Prepared by: Armando Chavez GLS Architecture Group 74491 Joni Dr. suite # 9 Palm Desert, Ca 92260_._, cam, 760 340.35.28 CITY OF LA C�VINTq BUILDING & SAFETY DEPT. LAPPROVED FOR CONSTRUCTION DA Iz i t BY Job Number: MAR 1 i; . 11 Date: 3/9/2011 The. EnergyProcomputer program has been.used to perform the calcutations!summarized in.this compliance report This program has approval and is authorized by the California Energy Commission for use with both,the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www,.energysoft.com. EnergyPro 5.1 by EnergySoff User Number. 5553 RunCode. 2011-03,09710:54915 ID. z 'TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary EnergyPro 5.1 by EnergySoft Job.Number. ID: User Number: 5553 1 2 3 12 15 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name ADAMS RESIDENCE Building Type ® single Family Q Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteratlon Date M12011 Project Address 77153 CASA DEL SOL LA QUINTA California Energy Climate Zone . CA Climate Zone 15 Total Cond. Floor Area 2907 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑, No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes El' No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavi ( Features see Part 2. of 5 Status Wal! Wood Framed R-19 2437 New Door Opaque Door None 96 New Roof Wood Framed Attic R-38 Z150 New Slab Unheated Slab -on -Grade None 2907 Perim = 311' New Roof Wood Framed Ratter R-30 757 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (NE) 78.0 0.400 0.35 2.0 none Bug Screen New Rear (NE) 16.0 0.400 0.35 10:0 none Bug Screen New Left, (NKI 8.0 0.400 0.35 2.0 none Bug Screen New Left (Alm 4.0 0.400. 0.35 2.0 none Bug Screen New Left (AfM 21.0 0.400 0.35 2.0 none Bug Screen New Front (SW) 25.0 0.400 0.35 2.0. none Bug Screen New Right (SE) 20.0 0.400 0.35 2.0 none Bug°Screen New Left (NKK 7.'0 0:400 0.35 2.0 none Bug Screen New Front (SW) 70 0.400 0.35 2.0 none Bug Screen New Right (SE) 5.0 0.400 0.35 2.0 none Bug Screen New Rear (NE) 120 0.400 a35 4.0 none. Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80%AFUE Split Air Conditioner 13.0 SEER Selback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HAVC-NEW Ducted Ducled Attic, Ceiling Ins; vented a0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 Kitchen Pipe Ins New �VnargyPro 5.1 by EnergySoft User Number. 5553 RunCode. 2011-03-09110:54:15 ID: Page 3 of 15 PERFORMANCE CERTIFICATE: Residential ' (Part 1 of 5 CF -1 R Project Name ADAMS RESIDENCE Building Type ® Single Family 0 Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date "12011 Project Address 77153 CASA DEL SOL LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,907 Addition fva # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST Q Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavi ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (NE) 48.0 0.400. 0.35 4.0 none Bug Screen New Rear (NE) 48.0 0.400 0:35 4.0 none- Bug Smen New Rear (NE) 12.0 0.400, 0:35 4..0 none Bug Screen New Front.(SKI 160.0 0.400 0;35 10.0 none Bug Screen New Rear (NE) 3.0 0.400 0:35 4.0 none Bug Screen New Rear (NE) 3:0 0.400 0.35 4.0 none Bug Screen New Rear (NE) 3.0 0.400 "0:35 4:0 none Bug Screen New Rear(NE) 10.0 0.650 0.48 4.0 none Bug Screen New Front(SK9 48.0 0.400 0.35 2.0 none Bug. Speen New Right (SE) 6.0 0.400 0.35 2.0 none Bug Speen New Right (SE) 10.0 0.650 a48 2.0 none Bug Speen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location/ Heating Cooking Duct..Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status rEn-ergyPro,5.1 by,EnergySoft User Number. 5553 RunCode: 2011.03-09T10s4.15 ID: Page 4 of 15 PERFORMANCE CERTIFICATE-: - Residential Part 1 of 5 CF -1R Project Name ADAMS RESIDENCE Building Type 0 Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date ")2011 Project Address 77153 CASA DEL SOL LA QUINTA California Energy Climate Zone, CA Climate Zone 15 Total Cond. Floor Area 2,907 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST F7 Yes ❑ No HERS Measures— If Yes, A -CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes EINo Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction. Type Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(fl Factor SHGC Overhang Sidefins Shades Status Right (SE) 4.0 0.400 0.35 2.0 none Bug Screen New RightfSE) 4:0 0.400 0.35 2:0 none Bug Screen New Right (SE) 8.0 0:400 0.35 2.0 none Bug Screen New Right (SE) 8.0 6.400 0:35 2.0 none Bug Screen New Rear (E) 6.0 0:400 0.35 2.0 none Bug Screen New Front (VII 18.3 0.400 0.35 2.0 none Bug Screen New Front (W) 18.3 0.400 0.35 2.0 none Bug Screen New Right'(S) 350 0.400 0.35 2.0 none Bug Screen New Right (S) 6.0 0.400 0.35 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number., 5553 RunCode. 2011.0349T10r54:15 ID: Page 5 of 15 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name ADAMS RESIDENCE Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/5/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special, attention to the items specified in this checklist. These iterins require special written justification and documentation, and special` verification to be used with the performance approachThe enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System YorkCZB36.PS8816N80.1200chn includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HAVC-NEW incorporates HERS Verfied Refrigerant Charg&ora Charge Indicator Display. HAVC-NEW'includes verified duchsystems that have air leakage to outside conditions equal to or less than, 25 cfm. HERS field verification for ducts in conditioned space and duct leakage is required. EnerayPro 5:1 by Ene Soft User Number. 5553 RunCode: 2011-03-09Ty0:54r15 1D: Peae 6 of 15 PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF-1 R Project Name Building Type 10 Single Family 13 Addition Alone Date ADAMS RESIDENCE 1 0 Multi Family 0 Existing+ Addition/Alteration 3/9/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft? Space Heating 4.65 3.88 0.77 Space Cooling 56:96 53,94 3.01 Fans 11.79 14.76 -2.97 Domestic Hot Water 12.55 12.43 0.11 Pumps 0.00 0.00 0.00 Totals 85.95 85.02 0:93 Percent Better Than Standard: 1.1 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building. Front Orientation: (SI49 225 deg Ext. Walls/Roof Wali Area Area Number of Dwelling Units: 1.00 (SW 841 277 Fuel Available at Site: Natural Gas (NK9 656 40 Raised Floor Area: 0 (NE) 945 239 Slab on Grade Area: 2.907 (SE) 753 106 Average Ceiling Height: 10.4 Roof 2,907 0 Fenestration Average U-Factor: 0.41 TOTAL: 662 Avera a SHGC: 0.35 Fenestration/CFA Ratio: 22.8% REMARKS s STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. ` The documentation author hereby certifies thatthe documentation is accurate and complete Documentation Author Company GLS Ard►itectun9 Group 39/2011 Address 74491 Joni Dr. suite #`9 Name -Armando Chavez Ci ip Palm Desert, Ce 92260Phone 760 340.35.28 ionif Date The individual with overall design responsibility hereby certifies that the pr ed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality,. and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company GLS Architecture Group Inc. Address 74491Joni Dr. Suite #9 Name Name City/State2p Palm Desert, Ca 92260 Phone 760 340.35.28 Signed License # Date EnemyPro 5.1 by Eire Soft User Number: 5553 RunCode: 20 1-03-09T10:54:15 /D: Page 7 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R. Project Name ADAMS RESIDENCE Building Type ® SingleFamily ❑ Addition Alone ❑ Multi, Family ❑ Existing+ Addition/Alteration Date 3/912011 OPAQUE SURFACE DETAILS Surface Type Area' U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 178 0.074 R-19 45 90 New 4.3.1 A5 NEW Door 24 0.500 None 45 90 New 4:5.1-A4 NEW Wall 330 0.074 R-19 315 90 New 4.3.1-A5 NEW Wall 238 0.074 R-19 225 90 New 4.3.1=A5 NEW Door 24 a500 None 225 90 'New 4:5.1-A4 NEW Wall 87 .0.074 R-19 135 90 New 4:3.1-M NEW Door 20 0.500 None 135 90 New 4.5.1-A4 NEW Roof 828 0.025 R�8 0 5 New 4.2:1 A21 NEW Slab 828 0:730 None 01 180 New 4:4.7 Al NEW Wall 24 0.074 R-19 45 90 New 4.3.17A5 NEW Wall 13 0.074 Wig 315 90 New 4.3:1-A5 NEW Wall 171 0:074 R-19 225 90 New 4:3:1-A5 NEW Wall 15 0:074 R-19 135 90 New 4.3.1-A5 NEW Roof 475 0.033 R-30 0 .5 'New 4.2:2-A41 NEW Slab 475 [ 0.730 None 01 180 New 4.4:7-A1 NEW Wall 901 OA74 R-19 1 451 90 New 4.3.IA5 INEW FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 54.0 0:400 NFRC 0.35 NFRC 45 New 2008 PRESCR. MWZ-15 NEW 2 Window 16.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDWZ=15 NEW 3 Window 4.0 0.400 NFRC a35' NFRC 315 New 2008 PRESCR. WDWZ-15 NEW 4 Window 40 a400 NFRC 0.35 NFRC 315 New 2008 PRESCR. 14DWZ--15 NEW 5 Window 21'.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW Z-15 NEW 6 Window 25.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW Z-15 NEW 7 Window 20.0 a400 NFRC 0.35 NFRC. 135 New 12008 PRESCR:. WDWZ,15 NEW 8 Window TO 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW Z 15 NEW 9 Window TO 0:400 NFRC a35 NFRC 225 New 2008 PRESCR. WDWZ-15 NEW 10 Window 5.0 0.400 NFRC 0.35 NFRC 135 New 2008'PRESCR. WDW Z-15 NEW 11 Window 12.0 0:400 NFRC. 0.35,, NFRC 45 New 2008 PRESCR. WDWZ-15 NEW 12 Window 48.0 0:400 NFRC '0.35' NFRC 45 New 2008 PRESCR. WDW Z-15 NEW 13 Window 48.0 0.400 NFRC 0.35' NFRC. 45 New. 12008 PRESCR: WDW Z-15 NEW 14 Window 12:0 0.400 NFRC 0.35' NFRC 45 New 2008 PRESCR. V10 Z-15 NEW 15 1Mhdow 160.0 0:400 NFRC 0.35 NFRC 225, New 2008 PRESCR. WDW Z-15 NEW 16 lWi7dow 3.01 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW Z-15 INEW (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGGT e: 116-6 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hana Left Fin Len H t LExt1 RExt Dist I Len I Right Fin Hat • Dist Len H t 1 Bug Screen 0.76 5.5 8.5 2.0 0.1 2.'01 2.0 2 Bug Screen 0:76 3.5 3:5 10.0 0..1 10.0 10:0 3 Bug Screen 0.76 1.5 1.5 2.0 0,1 2;0 2.0 4 Bug Screen 0.76 1.5' 1.5 2.0 0.1 2:0 2.0 5 Bug Screen 0.76 6.51 2:5 201 0..1 2.0 2.0 6 Bug Screen 0.76 .6.5 2.5 2:0 a i 2:0 2.0 7 Bug Screen 0.76 6.5 2.5 2.0 0.1 2.0 2:0 8 Lug Screen 0:76 1.0 6.5 2.0 0.1 2.01 2:0, 9 Bug Screen 0.76 1.0 6.5 2.0 0:1 201 2:0 10 Bug Screen 0.76 1.6 4.5 2.0 a i 2.01 2:0 11 Bug Screen 0.76 1.5 5.5 4.0 0.1 4:0 4:0 12 Bug Screen 0.76 6.5 5.5 4.0 0:1 4.0 4.0 13 Bu Screen 0.76 6.5 5.5 4.0 0.1 4:0 4.0 14, Bug Screen 0.76 1.5 5:5 4.0 0.1 4.0 4:0 15Bu Screen 0.76 9.5 15.5 10.0 0.1 10.0 10:0 16 ]Bug Screen A 76 1.0 1.5 4.0 0.1 4.0 4.01 1 Fn -&MY% 5.1 by EnergySoft. User Number. • 5553 RunCode: 2011-03-09710:54:15 ID: Pow 8 of 15 CERTIFICATE OF COMPLIANCE: Residential. (Part 4 of 5) CFA R Project Name ADAMS RESIDENCE I Building Type ®Single Family. Q AddibiDn Alone 13 Multi Family ❑ Existing+ Addition%Alteration I Date 3/9/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix .Tilt Status 4 Location/Comments Wall 35 0.074. R-19 225 90 New 4.3..1-A5 NEW Wall 305 0.074'R-19 45 90 New 4.3.1_A5 NEW Wall 2731 0.074 R-19 315 90, New 4.3.1-A5 NEW Wall 93 0.074 R-19 225 90 New 4.3.1-A5 NEW Door 280.500 None 225 90 New 4.5.1 A4 NEW Wall 368 0.074 R-19 135 90 New 4.3.1-A5 NEW Roof 1,322 0.025 R-38 0 5 New 4.2.1 A21 NEW Slab 1,604' 0.730 None 0 180 New 4.4.7A1 NEW Wall 85 0.074 R-19 90 90 New 4.3.1 A5 NEW Wall 129 0.074 R-19 270 90 New 4.3:1-A5 NEW Wall' 157 0.074 R-19 180 90 New 4.3:1-A5 NEW Roof 282 0.033 R-30 0 5 New 4.2.2-A41 NEW FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 3.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. MW Z-15 NEW 18 Window 3.0 a400 NFRC a35 NFRC 45 New .2008 PRESCR. WDWZ--15 NEW 19 Window 10.0 0.650 NFRC 0.48 NFRC 45 New WECK, GLASS BLOCKr 8x8x4 NEW 20 Window 24.0 0.400. NFRC 0.35 NFRC 45 New 2008 PRESCR.. WDWZ-15 NEW 21 Window 1 4.0 0.400 NFRC 0.35 NFRC 1 315 New 12008PRESCR. WDWZ-15 NEW 22 Window 48.0 0.400 NFRC 0.35' NFRC 225 New 12008 PRESCR. KVW Z-15 NEW 23 Window 6.0 0.400 NFRC 0.35 NFRC 135 New 2008'PRESCR. WDWZ-15 NEW 24 Wcndow 10.0 0.650 NFRC 0.48 NFRC 135 New WECK GLASS BLOCK 8x8x4 NEW 25 Window 4.0 0.400 NFRC 0.35 NFRC 135 New 2008'PRESCR. WDW Z-15 ' NEW 26 Window 4.0 0.400 NFRC 0. 35,1 NFRC 135 New 2008 PRESCR. WDW Z-15 NEW 27 lMndow 8.0 0.400 NFRC 0.35 NFRC 135 New 2008PRESCR. WDW Z45 NEW 28 Window 8.0 0.400 NFRC 0.35 NFRC 135 New 2008'PRESCR. WDWZ-15 NLEIV 29 Window 6.0 0.400 NFRC 0.35 NFRC 90 New 2008 PRESCR: WDW Z-15 NEW 30 Window 18.3 0.400 NFRC 0.35 NFRC 270 New 2008 PRESCR. MWZ-15 NEW 31 Window 18.3; 0.400 NFRC 0.35 NFRC 270 New 2008 PRESCR. WOW Z-15 NEW 32 Window X01 0.400 1 NFRC I 0.35 NFRC 180 'New '2008 PRESCR. WDW Z-15 INEW (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS' ID Exterior Shade Type SHGC Window Hat Wd Ove hana Left Fin Ri ht in Len H t LExt I REA Dist Len I H t Dist Len H t 17 Bug Screen. 0.76 1.0 1.5 4.6 0.1 4.01 4.0 18 Bug Screen 0:76 1.0 1.5 4.0 0.1 4.01 4.0 19 Bug Screen 0.76 1.0 1.5 4.0 0.1 4:0 4.0 20 Bug Screen 0.76 3.5 5.5 2.0- 0.1 2.0 2.0 21' Bug Screen 0.76 1.5 1111::1.5 2.01 0.1 2 0 2.0 22 Bug Screen 0.76 7.5 5.5 2;01 0.1 2.0 2.0 23 Bug Screen 0.76 1.5 2.5 2.01 a 1 2.0 2.0 24 Bug Screen 0.76 3.5 2.0 2.0 0.1 20 2;0 25 Bug Screen a76 1.5. 1.5 2.0 0.1 2.0 2:0 26 Bug Screen 0.76 1.5 1.5 2.0' 0.1 2.0 2:0 27 Bu Screen 0:76 3.5 1:5 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 3.5 1.5 2.0 0'1 20 2.0 29 Screen 0.76 3.5 2.0 2.0 0.1 2.0 2.0 30 _Bug Bug Screen 0.76 4.5 3.5 2.0 0:1 2:0 2.0 31 ISug Screen 0.76 45 3.5 zol 0.11 2.01 2.01 1 32 IBug Screen 1 76 4:5 6.5 201 0.11 2.01 201 1 Ewe Pro 5.1 by EnergySoff User Number. 5553 RunCode. 2011-03-09710:54:15 /D: Page 9 of 15 I • •MIMMEMEM . I RESIDENCE ADAMS 0 Multi Family 13 Existing+Addition/Alteration . I OPAQUE DETAILS Insulation Joint Appendix 511 ®R: M N ff 4 Locabon/Comments FENESTRATION SURFACE DETAILS 2008 PRESCR. EXTERIOR SHADINDETAILS CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name ADAMS RESIDENCE Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/5/2011 BUILDING ZONE INFORMATION System Name Floor Area Zone Name New Existina Altered Removed Volume Year Built HAVC-NEW ZONE 828 828 8,280 ZONE 475 475 5,938 ZONE 1604 1,604 16,040 Totals 2,907 0 01 0 HVAC SYSTEMS System Name Qty. Heating Type 'Min. Eff: Cooling Type Min. Eff. Thermostat Type Status HAVC-NEW 2 Central Furnace 80% AFUE Split Air Conditioner 1 3. 0 SEER Setback New HVAC DISTRIBUTION System Name Duct Heating Cooling Duct Location R -Value Ducts Tested? Status HAVC-NEW Ducted Ducted Attic, Ceiling Ins, vented8.0 0 New 13 13 1 13 WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot. Ext. Tank Insul. R- Value Status Standard Gas 50.gal or Le 1 Small Gas i ftchen.Pipe Ins 40,000 50 0.58 n/a Na New MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 0 ,� Q _ System Name Pipe Length Pipe Diameter Insul. Thick. HP Plenum Outside Buried 13 13 13 Ene Pro. 5.1 by Energy,%ft. User Number: 5553 RunCode: 2011-03-09T10:54 15 ID: Pae 1.1 of. 15 MANDATORY MEASURES SUMMARY: Residential (Pagel of 3 MF -IR Project Name ADAMS RESIDENCE Date 3/9/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate, of Compliance. (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory. Measures Summary shall be incorporated' into the permit documents, and theapplicablefeatures shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with Plan& Building Envelope Measures: 116(a)l: Doors -and. windows between conditioned and unconditioned spaces aremanufactured to limit air leakage. §11.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111'(a). 117: Exterior doors and windows are weather -stn d; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type.and include on CF -6R Form. §1180): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose°fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed. according to ASTM E1.677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material. alone without facings is no greater than 0.3%; water vapor permeance rate is no: reaterthan 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A:. Masonry orfactory-built fireplaces have a closable metal or glass door covering the entire opening of"the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at'least six square inches in area and'is equipped with.a with a readily accessible, operable, and tight -fitting damper and or a combustion-aircontrol.device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a`firebox jacket, when that indoor air is vented to the outside of the. building,are prohibited. Space Conditioning, Water Heatin nd Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the:Energy Commission. §113(c)5: Water heating recirculation loops serving multiple: dwelling units and High. =Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA. §1500): Heating systems are equipped with thermostats that -meet the setback. requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped With insulation, having an installed thermal resistance of R-12 or greater. §1500)113' Unfired storage tanks, such as storage tanks or backup tanks for solarwater=heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internaHnsulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank,non-recirculating systems, and entire length of recirculating sections of bot water pipes are insulated per Standards Table.150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot_ watertank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot'water systems >15 psi, meets the requirements of Standards Table 123-A. §1,500)3A: Insulation is protected from damage, includin .that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely -in conditioned space. 1NOW Solar water-heatin . systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoR User Number. • 5553 RunCode: 2011-03-09T10:54:15 ID: Page. 12 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -IR Project Name Date ADAMS RESIDENCE 3/9%2011 §150(m)1; All air -distribution system ducts and plenums installed, are sealed and insulated to meet the, requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and, plenums are insulated to a. minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL'181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 Inch, the combination of mastic and either mesh or tape shall be used §150(m)1:: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shallnot be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of'the ducts. . §150(m)2D: Joints and seams of duct systems and their components shall,not.be sealed with cloth back rubber adhesive duct tapes unless such t e is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that duetosunlight, moisture, equipment maintenance, and wind. Cellular foaminsulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause: de radation of the material.. 150 m 10: Flexible ducts cannot have porous inner cores.. §150(o):.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not.a permissible method of providing the. Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems rand Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with,operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)l : Any pool or spa heating equipment shall.be installed with at least.36" of pipe betweenJilter and heater, or dedicated,suction and return lines, or built-up connections for future solar heating. 174(b)2. Outdoor pools or spas that have a heatpum or gas heater shall have a cover. §1'14(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch thatwill allow all pumps.to be set or programmed to run only during off -peak -electric demand periods. 150 : Residential pool -systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacyduminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is nota low efficacy luminaire asspecified by §150(k)2,. §1,50(k)3: The watts e..of permanently installed luminaires..shall be determined as specified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in. Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other -than kitchens, shall meet theapplicable requirements of §150 k §150(k)7: All switching devices and controls shall meet the requirements of 150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy _requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (.EMCS), or a multi -scene programmable control system; and all permanently installed luminaries In.garages, laundry rooms, closets greater than 70 -square feet,. and utility rooms are high efficacy, and controlled by a manual -on occupant, sensor. §150(k)9: Permanently installed lighting that is internal to. cabinets shall use no more than 20 watts iof power, per linearfoot of illuminated cabinet. EnergyPro 5:1 by EnergySoft User Number: 5553 RunCode: 2011-03-09710:54:15 IDr Page 13 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 M.F-1R Project Name Date ADAMS RESIDENCE "/2011 §150(k)l0: Permanently installed; luminaires in bathrooms,attached. and detached garages, laundry'rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed'low efficacy luminaires In closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11`- Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms,, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled byeither a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTIONZ Lighting in detached storage building less than 1000.s uare feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory,;' and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies; and porches, which are permanently mounted to axesidential building or to other buildings on the same lot shall'be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that. they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not�having an override or'bypass.switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3:' Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the -California. Electric Code need not be high efficacy luminaires. §1.50(k)1.4: Internally illuminated address signs shall comply With Section 148; OR not contairn a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carportsvith a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132,134, and 147. Lighting for parking garages for 8 or more vehicles.shall comply with the applicable requirements of Sections 130, 131- ,134, and'146., §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be, allowed provided that thev are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by.EnergySoft User Number. 5553 RunCode: 2011,03-09T10:54:15 /D: Page 14 of 15 HVAC'SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name. ADAMS RESIDENCE Date 3/9/2011 System Name HAVC-NEW Floor Area 2,907 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,094 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK Sensible 42,896 0 0 0 0 0 0 1 42,896 COIL HTG. Latent CFM 4,502 '817 0 0 4,502 PEAK Heating System Sensible Output OrSystem 64,000 43,574 Total Output Stuh 128,000 Output Btuh/ 44.0 0 Cooling System 0 output per System 35;000 0 Total Output Btuh 70,000 0 Total Output ons 5.8 0 Total Output Btuh/ 24.1 Total Output s on 498:3 43,574 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,400 YorkCZB36.PS8B16N80.1200dm 49,155 13,070 128,000 128,000 Jan 1 AM Airflow clm/ 0.83 Airflow cfm/Ton) 411.4 Outside Air % 0.0% Total Adjusted System Output 4P,1551 (Adjusted foe Peak Design conditions) TIME OF SYSTEM PEAK 13,070 Aug 3 PM Outside Air chW 0;00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 dm Supply Fan 2,400 dm ' 70'OF70 70 OF 120 OF. Heating Coil -TT.A � - 120 OF _..___...---..._._......__—, ROOM OF COOLING SYSTEM PSYCHROMETICS Airstream Temperaturesst Time of Cooling Peak 112 / 78 OF 78165 OF 78 / 65 OF 59 / 58 OF Outside Air 0 dm Su Fan Supply Cooling Coil 2,400 dm 78 / 65 OF LJEnergyPro 50.1% O ,, 59 / 58 F ( R OM �— 78 / 65'OF 5.1 by EnergySoR. User Number. • 5553 RunCode. °2011-63-09710:54:15 ID: - Page 15 of 15