13-0247 (SFD) Title 24t A BUILDING ENERGY ANALYSIS REPORT PROJECT: West Residence . Traditions, Lot 14 La Quinta, CA 92253 Project Designer: � Helton, DeFord & Associates " ,1261 N. Big Spring Street Anaheim, Ca 92807 LA LA QUIN (909)957-4550 APP&sAFo-yDEP FOR CO R VED UCTION Report Prepared by: [DA e Tim Scott -2� Scott Design and Title 24, Inc, �d 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Date: 2/25/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. - EnerovPro5.1 by EnerovSoR User Number: 6712 RunCode: 2013-02-25717:27:14 ID: 'I* 40 TABLE OF CONTENTS 'Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 19 Room Heating Peak Loads 23 Room Cooling Peak Loads 28 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 7 C 'I* 40 TABLE OF CONTENTS 'Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 19 Room Heating Peak Loads 23 Room Cooling Peak Loads 28 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 • r • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name West Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 Project Address Traditions, Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 4,657 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ( Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,657 Radiant Barrier New Wall Wood Framed R-21 4,173 New Slab Unheated Slab -on -Grade None 4,980 Perim = 540' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (S) 200.5 0.390 0.32 none none Bug Screen New Right (W 217.0 0.390 0.32 none none Bug Screen New Front (N) 63.4 0.390 0.32 none none Bug Screen New Left (E) 141.2 0.390 0.32 none none Bug Screen New Rear (S) 190.0 0.390 0.32 15.0 none Bug Screen New Right (W) 60.3 0.390 0.32 10.0 none Bug Screen New Front (N) 72.0 1.190 0.59 4.0 none Bug Screen New Left (SE) 24.0 0.390 0.32 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Fumace 97% AFUE Split Air Conditioner 17.7 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Small Gas 50 0.80 All Pipes Ins New Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 3 of 34 • r • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name West Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 Project Address Traditions, Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,657 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 97% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING City. Type Gallons Min. Eff Distribution Status —EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 4 of 34 • 0 Ll PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. IGH MASS Design - Verify Thermal Mass: 773.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 360.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite The HVAC System HVAC 2 & 3 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 260.0 ft2 Covered Slab Floor, 3.500" thick at GreatWitchen/Dining HIGH MASS Design - Verify Thermal Mass: 1,864.0 ft2 Exposed Slab Floor, 3.500" thick at GreaWitchen/Dining The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 534.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 534.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4 HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4 The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 324.0 ft2 Covered Slab Floor, 3.500" thick at Guest Suite HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required.to verify that duct leakage meets the specified criteria. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 5 of 34 s :7 a PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 135.0 ft2 Exposed Slab Floor, 3.500" thick at Guest Suite The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnePro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 6 of 34 0 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date West Residence []Multi Family ❑ Existing+ Addition/Alteration 1212512013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/fe- r Space Heating 4.61 3.41 1.19 Space Cooling 54.73 45.75 8.99 Fans 11.04 11.49 -0.46 Domestic Hot Water 7.83 6.40 1.43 Pumps 0.00 0.00 0.00 Totals 78.21 67.06 11.15 Percent Better Than Standard: 14.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 345 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 986 135 Fuel Available at Site: Natural Gas (E) 1,557 165 Raised Floor Area: 0 (S) 1,118 391 Slab on Grade Area: 4,980 (lM 1,504 277 Average Ceiling Height: 11.5 Roof 4,657 0 Fenestration Average U -Factor: 0.45 TOTAL: 966 Average SHGC: 0.34 Fenestration/CFA Ratio: 20.8% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author - Company Scott Design and Title 24, Inc, 5/2013 _ Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Helton, DeFord & Associates Address 1261 N. Big Spring Street Name Jim Deford City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed license If Date EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 7 of 34 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name West Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor C­a­v_it_yTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,133 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Zone Wall 275 0.069 R-21 75 90 New 4.3.1-A6 Master Suite Zone Wall 157 0.069 R-21 165 90 New 4.3.1-A6 Master Suite Zone Wall 534 0.069 R-21 255 90 New 4.3.1-A6 Master Suite Zone Wall 193 0.069 R-21 345 90 New 4.3.1-A6 Master Suite Zone Slab 773 0.730 None 0 180 New 4.4.7-A1 Master Suite Zone Slab 360 0.730 None 0 180 New 4.4.7-A 1 Master Suite Zone Roof 2,124 0.026 R-38 270 0 New 4.2.1-A9 Living Zone Wall 453 0.069 R-21 75 90 New 4.3.1-A6 Living Zone Wall 378 0.069 R-21 165 90 New 4.3.1-A6 Living Zone Wall 234 0.069 R-21 255 90 1 New 4.3.1-A6 Living Zone Wall 238 0.069.R-21 345 90 New 4.3.1-A6 LivingZone Door 24 0.500 None 345 90 New 4.5.1-A4 LivingZone Slab 260 0.730 None 0 180 New 4.4.7-A1 LivingZone Slab 1,864 0.730 None 0 180 New 4.4.7-A1 Livin Zone Roof 632 0.026 R-38 270 0 New 4.2.1-A9 Bedroom 2, 3 & 4 Zone FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 80.0 0.390 NFRC 0.32 1 NFRC 1651 New Double Non -Metal Tinted Master Suite Zone 2 Window 18.0 0.390 NFRC 0.32 NFRC 1651 New Double Non -Metal Tinted Master Suite Zone 3 Window 5.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 4 Window 5.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 5 Window 5.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 6 Window 12.5 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 7 Window 12.5 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 8 Window 6.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 9 Window 12.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 10 Window 12.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 11 Window 12.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 12 Window 12.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 13 Window 1 12.01 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 14 Window 2.31 0.390 1 NFRC 1 0.32 NFRC 345 New Double Non -Metal Tinted Master Suite Zone 15 Window 2.31 0.390 1 NFRC 1 0.32 NFRC 1 345 New Double Non -Metal Tinted Master Suite Zone 16 Window 1 2.31 0.390 1 NFRC 1 0.32 1 NFRC 1 345 New Double Non -Metal Tinted Master Suite Zone (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right in H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen _ 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 8 of 34 • c: CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name West Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512013 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 364 0.069 R-21 75 90 New 4.3.1-A6 Bedroom Z 3 & 4 Zone Wall 55 0.069 R-21 165 90 New 4.3.1-A6 Bedroom Z 3 & 4 Zone Wall 40 0.069.R-21 255 90 New 4.3.1-A6 Bedroom Z 3 & 4 Zone Wall 140 0.0690-21 345 90 New 4.3.1-A6 Bedroom Z 3 & 4 Zone Slab 534 0.730 None 0 180 New 4.4.7-A1 Bedroom 2, 3 & 4 Zone Slab 98 0.730 None 0 180 New 4.4.7-A1 Bedroom 2, 3 & 4 Zone Roof 309 0.026 R-38 270 0 New 4.2.1-A9 Bedroom 2, 3 & 4 Zone Wall 144 0.069 R-21 255 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Wall 60 0.069 R-21 345 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Slab 534 0.730 None 0 180 New 4.4.7-A1 Bedroom Z 3 & 4 Zone Slab 98 0.730 None 0 180 New 4.4.7-A 1 Bedroom Z 3 & 4 Zone Roof 459 0.026 R-38 270 0 New 4.2.1-A9 Guest Suite Zone Wall 234 0.069 R-21 75 90 New 4.3.1-A6 Guest Suite Zone Wall 66 0.069 R-21 120 90 New 14.3.1-A6 Guest Suite Zone Wall 138 0.069.R-21. 165 90 New 14.3.1-A6 Guest Suite Zone Wall 2751 0.069 1 R-21 1 1 2551 90 1 New 14.3.1-A6 I Guest Suite Zone FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 18 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 19 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 20 Window 2.3 0.390 NFRC 0.32 NFRC 751 New Double Non -Metal Tinted Living Zone 21 Window 1 20.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 22 Window 40.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 23 Window 20.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 24 Window 90.0 0.390 NFRC 0.32 NFRC 165 New Double Non -Metal Tinted Living Zone 25 Window 190.0 0.390 NFRC 0.32 NFRC 165 New Double Non -Metal Tinted Living Zone 26 Window 60.3 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Living Zone 27 Window 12.5 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Living Zone 28 Window 32.0 1.190 NFRC 0.59 NFRC 345 New Custom Entry Door Living Zone 29 Window 40.0 1.190 NFRC 0.59 NFRC 345 New Custom Entry Door Living Zone 30 Window 8.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 31 Window 8.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 32 Window 15.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = labeled Value EXTERIOR SHADING DETAILS ID ' Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right in H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 10.0 19.0 15.0 0.1 15.0 15.0 26 Bug Screen 0.76 9.0 6.7 10.0 0.1 10.0 10.0 27 Bug Screen 0.76 28 Bug Screen 0.76 8.01 4.0 4.0 0.1 4.0 4.0 29 Bug Screen 0.76 10.0 4.0 4.0 0.1 4.0 4.0 30 Bug Screen 0.76 31 IBug Screen 0.76 32 JBug Screen t 0.76 EnemyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 9 of 34 • • A CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name West Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 196 0.069 R-21 345 90 New 4.3.1-A6 Guest Suite Zone Slab 324 0.730 None 0 180 New 4.4.7-A1 Guest Suite Zone Slab 135 0.730 None 0 180 New 4.4.7-A1 Guest Suite Zone FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 15.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 34 Window 15.0 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 35 Window 15.0 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 36 Window 20.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 37 Window 40.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 38 Window 20.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 39 Window 6.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 40 Window 6.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Guest Suite Zone 41 Window 24.0 0.390 NFRC 0.32 NFRC 120 New Double Non -Metal Tinted Guest Suite Zone 42 Window 12.5 0.390 NFRC 0.32 NFRC 165 New Double Non -Metal Tinted Guest Suite Zone 43 Window 12.5 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Guest Suite Zone 44 Window 12.5 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Guest Suite Zone 45 Window 14.0 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Guest Suite Zone (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat I Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 Runcode: 2013-02-25717:27:14 ID: Pae 10 of 34 • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name West Residence Building Type 0Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existin Altered Removed Volume Year Built HVAC 1 Master Suite 1,133 12,236 HVAC 2 & 3 Great/Kitchen/Dining 2,124 27,187 HVAC 4 Bedroom 2 & 3 632 6,320 Bedroom 4 309 3,090 HVAC 5 Guest Suite 459 4,590 Totals 4,657 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 4 1 Central Furnace 97% AFUE Split Air Conditioner 17.7 SEER Setback New HVAC 5 1 Central Furnace 97% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.01 0 lNew HVAC 5 1 Ducted Ducted Attic, Ceiling Ins, vented 8.01 0 I New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White 50 Gal 2 Small Gas All Pipes Ins 40 50 0.80 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 01 1 EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25T17:27:14 ID: Page 11 of 34 0 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name West Residence Date 2/25/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. -§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. .,*§1 50(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled and installed according to ASTM Ell 677-95(2000) when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the -outside of the building, are prohibited. : Space Conditioning, Water Heating and Plumbing System Measures: _§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water 'tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the dank. '§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of -recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance, and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25T17:27:14 ID: Page 12 of 34 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date West Residence 1212512013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area • of the ducts. 50(m)21): Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes ,,§1 ..unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency ..Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. `§1 14 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain -only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a .medium screw -base socket. -.§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). -.4150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySolf User Number.' 6712 RunCode: 2013-02-25717:27:14 ID: Page 13 of 34 • r: • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date West Residence 2/25/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - "on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not .be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no -'more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. y. EnergyPro 5.1 by EnergySoR User Number.' 6712 RunCode: 2013-02-25T17:27:14 ID: Page 14 of 314 0 • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name West Residence Date 2/25/2013 System Name HVAC 1 Floor Area 1,133 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 668 13,317 Return Vented Lighting 0 Return Air Ducts 769 Return Fan 0 Ventilation o 0 Supply Fan 0 Supply Air Ducts 769 TOTAL SYSTEM LOAD 1 14,855 COIL HTG. Latent CFM 1,6481 449 01__0 1,648 PEAK Heating System Sensible -Output perSystem 59,000 16,121 Total Output Btuh 59,000 Output Btuh/s ft 52.1 792 Cooling System 0 Output perSystem 47,000 0 Total Output Btuh 47,000 0 Total Output ons 3.9 792 Total Output Btuh/s ft 41.5 Total Output s ft/Ton 289.3 17,705 ,Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION - Airflow cfm 1,600 Carrier 24ANB648/59MN7A60 33,432 Total Adjusted System Output 33,4321 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,093 59,000 4,093 59,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 1.41 Airflow cfm/Ton 408.5 Outside Air°/, 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 of dw 72 OF 106 OF 106 OF i Heating Coil Supply Fan 106 OF 1,600 cfm... ....... ................... ..... ..... _........ M ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 70 / 58 OF 70/58°F 51 /50°F 51 /50°F Cooling Coil Supply Fan 51 / 50 OF 1,600 cfm 48.5% , ROOM l 70/ 58 OF EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 15 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name West Residence Date 2/25/2013 System Name HVAC 2 & 3 Floor Area 2,124 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,317 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 59,000 26,378 2,915 824 29,640 Total Output Btuh 118,000 o Output Btuh/s ft 55.6 1,523 1,457 Cooling System o 0 Output per System 47,000 0 01 0 0 Total Output Btuh 94,000 0 2,915 0 Total Output ons 7.8 1 1,523 1,457 Total Output Btuh/s ft 44.3 Total Output s ft/Ton 271.1 29,424 32,554 "Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION - Airflow cfm 3,200 Carrier 24ANB648/59MN7A60 67,163 7,779 118,000 118,000 Jan 1 AM Airflow cfm/s ft 1.51 Airflow cfm/ron 408.5 Outside Air % 0.0% Total Adjusted System Output 67,163 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 7,779 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak 26 of Outside Air 0 cfm 72 of 72 of 106 of 106 OF Heating Coil Supply Fan 106 OF 3,200 cfm ROOM 72 of COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air Ar 0 cfm 70 158 of 70/58OF 51 /50OF 51 /50OF Cooling Coil Supply Fan 51 / 50 of 3,200 cfm 48.1 % ROOM 70 / 58 of EnergyPro 5.1 by EnergySoR User Number.- 6712 RunCode: 2013-02-25717:27:14 /D: Page 16 of 34 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name West Residence Date 2/25/2013 System Name HVAC 4 Floor Area 941 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 574 11,473 Return Vented Lighting 0 Return Air Ducts 662 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 662 TOTAL SYSTEM LOAD 12,798 COIL HTG. Latent I CFM 1,603 301 01 0 1,603 PEAK Heating System Sensible Output perSystem 59,000 14,460 Total Output Btuh 59,000 Output Btuh/s ft 62.7 711 Cooling System 0 Output perSystem 35,500 0 Total Output Btuh 35,500 0 Total Output ons 3.0 711 Total Output Btuh/s ft 37.7 Total Output s ft/Ton 318.1 1 15,882 "Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB736/59MN7A60 25,308 3,070 59,000 Airflow cfm/s ft 128 Total Adjusted System Output 25,308 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Airstream Temperatures at Time of Heating Peak 3,070 1 59,000 Aug 3P M Jan 1 AM Airflow cfm/Ton 405.6 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26 OF Outside Air 0 cfm 71 OF 71 OF 118 OF 118 °F Heating Coil Supply Fan 117 OF 1,200 cfm ROOM 72 OF _COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F . Outside Air 0 cfm 71 158 OF 71/58°F 51/50°F 51/50°F MR © - c Cooling Coil Supply Fan 51 / 50 OF 1,200 cfm - 48.7 Bio ROOM In 70 / 58 OF EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 17 of 34 L -J 0 -.HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name West Residence Date 2/25/2013 System Name HVAC 5 Floor Area 459 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 310 6,392 Return Vented Lighting o Return Air Ducts 369 Return Fan 01 Ventilation o 0 Supply Fan 0 Supply Air Ducts 369 TOTAL SYSTEM LOAD 1 7,130 COIL HTG. Latent I CFM 787 129 0 0 787 PEAK Heating System Sensible Output per System 59,000 9,376 Total Output Btuh 59,000 Output Btuh/s ft 128.5 461 Cooling System 0 Output per System 24,000 0 Total Output Btuh 24,000 0 Total Output ons 2.0 461 Total Output Btuh/s ft 52.3 Total Output s ft/Ton 229.5 10,297 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24ANB724/59MN7A60 17,219 1,846 59,000 Alrflow cfm/s ft 1.74 Total Adjusted System Output 1 17,2191 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 1,846 59,000 Aug 3 PM I Jan 1 AM Airflow cfm/Ton 400.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 -Note: values above given at ARI conditions .-HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm Ar 71 OF 71 OF 141 OF 141 OF Heating Coil Supply Fan 800 cfm 140 o F 1--ROOM- 72 OF „COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 70158 OF 70 / 58 OF 50 / 49 OF 50 / 49 OF Cooling Coil Supply Fan 800 cfm 47.2% 51 / 49 OF i p j ROOM 70 / 58 OF EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-02-25717:27:14 /D: Page 18 of 34 • ROOM LOAD SUMMARY Project Name Date West Residence 2/25/2013 System Name Floor Area HVAC 1 1,133 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Zone Master Suite 1 668 13,317 1,648 668 13,317 1,648 449 16,121 XH PAGE TOTAL TOTAL* 668 13,317 1,648 449 16,121 668 13,317 1,648 449 16,121 Total includes ventilation load for zonal systems. Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Pa a 19 of 34 • ROOM LOAD SUMMARY Project Name Date West Residence 2/25/2013 HVAC 2 & 3 1 2,124 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM Sensible Living Zone GreatlKitchen/Dining 1 1 1 1,3171 26,3781 2,915 1,3171 26,378 2,915 824 29,640 PAGE TOTAL 1,317 26,378 2,915 824 29,640 • TOTAL' 1,317 26,378 2,915 824 29,640 ' Total includes ventilation load for zonal systems. 0 • • ROOM LOAD SUMMARY Project Name Date West Residence 2/25/2013 System Name Floor Area HVAC 4 941 ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible Latent CFM Sensible Bedroom 2, 3 & 4 Zone . Bedroom 2 & 3 1 1321 6,410 1,008 321 6,410 1,008 175 8,379 Bedroom 4 1 253 5,0631 595 253 5,063 5951 127 6,081 PAGE TOTAL TOTAL* 574 11,473 1,603 301 14,460 574 11,473 1,603 301 14,460 * Total includes ventilation load for zonal systems. EnerqvPro 5.1 by Enem YSoft User Number: 6712 RunCode: 2013-02-25717:27:14 /D: Pa a 21 of 34 • • ROOM LOAD SUMMARY Project Name Date West Residence 2/25/2013 System Name Floor Area HVAC 5 459 Zone Name I Room Name I Mult. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible Guest Suite Zone I Guest Suite I 1 1 3101 6,3921 7871 3101 6,3921 7871 1291 9,376 PAGE TOTAL 310 6,392 787 129 9,376 01.TOTAL 3101 6,392 787 129 9,376 Total includes ventilation load for zonal systems. • • • ROOM HEATING PEAK LOADS Project Name Date West Residence 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Time of Peak Jan 1 AM Floor Area 1,133.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R.38.2x14.16) 1,133.0 X 0.0260 X 46 = 1,355 R-21 Wall (W.19.2x6.16) 1,159.1 X 0.0690 X 46 = 3,679 Double Non -Metal Tinted 210.9 X 0.3900 X 46 = 3,784 Slab -On -Grade perim = 130.0 X 0.7300 X 46 = 4,365 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 13,183 Infiltration:[ 1.00 X 1.064 X 1,133 X 10.80 X 0.294 /60] X 46 = 2,938 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,121 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 23 of 34 • 0 ROOM HEATING PEAK LOADS Project Name West Residence Date 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Dining Floor Area 2,124.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R. 38.2x 14.16) 2,124.0 X R-21 Wall (W.19.2x6.16) 1,302.0 X Double Non -Metal Tinted 442.0 X Custom Entry Door 72.0 X Wood Door 24.0 X Slab -On -Grade perim = 150.0 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 2,124 X Schedule Air Sensible Area Ceiling Fraction U -Value 0.0260 X 0.0690 X 0.3900 X 1.1900 X 0.5000 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X another room 12.80 X 0.248 Height ACH AT *F 46 = 46 = 46 = 46 = 46 = 46 = = = = = = = = = = = = = = = = = = = = = = = = = = Page Total /60] X 46 AT Btu/hr 2,540 4,133 7,929 3,941 552 5,037 1 24,133 = 5,508 TOTAL HOURLY HEAT LOSS FOR ROOM 29,640 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-02-25T17:27:14 ID: Page 24 of 34 • • ROOM HEATING PEAK LOADS Project Name West Residence Date 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 & 3 Floor Area 632.0 ft' Indoor Dry Bulb Temperature - 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R. 38.2x 14.16) 632.0 R-21 Wall (W.19.2x6.16) 599.0 Double Non -Metal Tinted 76.0 Slab -On -Grade perim = 81.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 632 X Schedule Air Sensible Area Fraction U -Value AT OF X 0.0260 X 46 X 0.0690 X 46 X 0.3900 X 46 X 0.7300 X 46 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room Page Total 10.00 X 0.318 /60] X Ceiling Height ACH AT = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr 756 1,901 1,363 2,720 6.741 = 1,639 TOTAL HOURLY HEAT LOSS FOR ROOM 8,379 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 25 of 34 0 • • ROOM HEATING PEAK LOADS Project Name West Residence Date 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Floor Area 309.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R. 38.2x 14.16) 309.0 R-21 Wall (W. 19.2x6.16) 204.0 Double Non -Metal Tinted 86.0 Slab -On -Grade perim = 81.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 309 X Schedule Air Sensible Area Fraction X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value 0.0260 X 0.0690 X 0.3900 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X another room 10.00 X 0.318 Height ACH AT OF 46 = 46 = 46 = 46 = = = = = = = = = = = = = = = = = = = = = = = = = = = Page Total /60] X 46 AT Btu/hr 370 647 1,543 2,720 5,280 = 801 TOTAL HOURLY HEAT LOSS FOR ROOM 6,081 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Page 26 of 34 • • ROOM HEATING PEAK LOADS Project Name West Residence ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-38 Roof(R.38.2x 14.16) R-21 Wall (W.19.2x6.16) Double Non -Metal Tinted Slab -On -Grade DESIGN CONDITIONS Guest Suite Time of Peak 459.0ft' Outdoor Dry Bulb Temperature 72 OF Area U -Value 459.0 908.5 81.5 Perim = 98.0 0.0260 0.0690 0.3900 0.7300 Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 X 1.064 X 459 X 10.00 X 0.318 Schedule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY HEAT LOSS FOR ROOM . Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-25T17:27:14 ID: AT OF 46 46 46 46 Page Tc /60] XC Al Date 2/25/2013 Jan 1 AM 26 OF Btu/hr 549 Z884 1,462 3,291 tal 8,185 46 9,3761 RESIDENTIAL ROOM COOLING LOAD SUMMARY rroieci name West Residence ROOM INFORM Room Name Floor Area Indoor Dry Bulb Ti ODaaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation 2/25/2013 DESIGN CONDITIONS Master Suite Outdoor Dry Bulb Temperature 1,133.0 ft2 Outdoor Wet Bulb Temperature 70 OF Outdoor Daily Range: Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,133.0 0.0260 56.0 275.0 0.0690 31.7 157.0 0.0690 27.7 534.0 0.0690 32.31 193.1 0.0690 29.0 19.7 5.0 37.6 0.01 19.7 5.0 37.6 0.0 19.7 12.5 j 0.0 19.7 12.5 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Window Window Window Window Window Window Window Window Window AriPntatinn 112 °F 78 °F 34 OF Btu/hr 1,650 601 300 1,191 386 1 4,1281 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 19.7 80.0 22.2 0.0 19.7 18.0 22.2 0.0 19.7 5.0 37.6 0.0 19.7 5.0 37.6 0.01 19.7 5.0 37.6 0.0 19.7 12.5 37.6 0.0 19.7 12.5 37.6 0.0 19.7 6.0 37.6 0.0 19.7 12.0 37.61 Page Total Btu/hr 1,774 399 188 188 188 470 470 226 451 4,355 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 62.00 X 42 = 2,592 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,317 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4.771 X 0.94 X 62.00 X 0.00523 = 1,448 Air Sensible CFM EWA AW 0 1 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date West Residence 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,133.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor -CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = ` X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 0.0 X 19.7 + 12.0 X 37.6 = 451 Window 0.0 X 19.7 + 12.0 X 37.6 = 451 Window 0.0 X 19.7 + 12.0 X 37.6 = 451 Window (lM 0.0 X 19.7 + 12.0 X 37.6 = 451 Window (N) 0.0 X 19.7 + 2.3 X 30.0 = 69 Window (N) 0.0 X 19.7 + 2.3 X 30.0 = 69 Window (N) , 0.0 X 19.7 + 2.3 X 30.0 = 69 X + X - X 1 +1 X = Page Total 2,012 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 62.00 X 42 = 2,592 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,317 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 62.00 X 0.00523 = 1,448 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,648 EnerqyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2013-02-25717:27:14 /D: Page 29 of 34 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate West Residence 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name GreabKitchen/Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,124.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF R-38 Roof(R.38.2x 14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) Wood Door Orientation (E) (S) (tM (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = 2,124.0 0.0260 56.0 452.8 0.0690 31.7 378.0 0.0690 27.7 233.7 0.0690 32.3 237.5 0.0690 29.0 24.0 0.5000 29.0 0.0 19.7 20.0 35.8 0.0 19.7 40.0 I J I= 19.7 20.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanastratinn Window Window Window Window Window Window Window Window Window Orientation (E) (E) (E) (E) (E) (E) (E) (S) (S) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 19.7 2.3 35.8 0.0 19.7 2.3 35.8 0.0 19.7 2.3 35.8 0.0 19.7 2.3 35.8 0.0 19.7 20.0 35.8 0.0 19.7 40.0 35.8 0.01 19.7 20.0 35.8 0.0 19.7 90.0 22.2 190.0 19.7 0.0 22.21 Page Total Btu/hr 3,093 989 722 521 475 348 6, Btu/hr 82 82 82 82 715 1,431 715 1,996 1 3,7381 8, Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. Equipment 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.94 X 116.23 X 42 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26.3781 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 116.23 X 0.00523 = 2,715 Air Sensible CFM ELA AW • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date West Residence 1 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great/Kitchen/Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,124.0 8Z Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X X X X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (W) 60.3 X 19.7 + 0.0 X 37.6 = 1,186 Window (N) 0.0 X 19.7 + 12.5 X 30.0 = 375 Window (N) 0.0 X 45.7 + 32.0 X 64.7 = 2,069 Window (N) 0.0 X 45.7 + 40.0 X 64.7 = 2,587 X + X X + X = X + X = X + X = X +1 X = Page Total x,217 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 116.23 X 42 = 4,858 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26,378 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 116.23 X 0.00523 = 2,715 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,915 EnergyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Pacie 31 of 34 • • 11 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date West Residence 1 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 & 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 632.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 14.16) (M 632.0 X 0.0260 X 56.0 = 920 R-21 Wall (W. 19.2x6.16) (E) 364.0 X 0.0690 X 31.7 = 795 R-21 Wall (W. 19.24.16) (S) 55.0 X 0.0690 X 27.7 = 105 R-21 Wall (W.19.24.16) (W) • 40.0 X 0.0690 X 32.3 = 89 R-21 Wall (W. 19.24.16) (N) 140.0 X 0.0690 X 29.0 = 280 X X = X X = X X = X J X I= Page Total 2.190 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (E) 0.0 X 19.7 + 8.0 X 35.8 = 286 Window (E) 0.0 X 19.7 + 8.0 X 35.8 = 286 Window (E) 0.0 X 19.7 + 15.0 X 35.8 = 537 Window (E) 0.0 X 19.7 + 15.0 X 35.8 = 537 Window (N) 0.0 X 19.7 + 15.0 X 30.0 = 449 Window (N) 0.0 X 19.7 + 15.0 X 30.0 = 449 X + X = X + X = X +1 X = Page Total 2,544 Internal Gain Btu/hr- tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 34.58 I X 42 = 1,446 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,410 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 34.58 X 0.00523 = 808 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,008 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Pace 32 of 34 A C ., • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date West Residence 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 309.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces . Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) W 309.0 X 0.0260 X 56.0 = 450 R-21 Wall (W.19.2x6.16) (K9 144.0 X 0.0690 X 32.3 = 321 R-21 Wall (W. 19.2x6.16) (N) 60.0 X 0.0690 X 29.0 = 120 X X = X X = X X = X X = X X = X J X I= Page Total 891 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (W) 0.0 X 19.7 + 20.0 X 37.6 = 752 Window (WM 0.0 X 19.7 + 40.0 X 37.6 = 1,505 Window (IM 0.0 X 19.7 + 20.0 X 37.6 = 752 Window (W) 0.0 X 19.7 + 6.0 X 37.6 = 226 X + X - X + X = X + X - X + X - X +1 1XI- Page Total 3,235 Internal Gain Btu/hr- tu/hrOccu ants 1.0 Occupants X 230 Btuh/occ. = Occupants 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 16.91 X 42 = 707 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,063 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 16.91 X 0.00523 = 395 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 595 EnemvPro 5.1 by EnemySoft User Number- 6712 RunCode: 2013-02-25717:27:14 ID: Page 33 of 34 • • C7 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date West Residence 1 2/25/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 459.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 459.0 X 0.0260 X 56.0 = 668 R-21 Wall (W. 19.2x6.16) (E) 234.0 X 0.0690 X 31.7 = 511 R-21 Wall (W.19.2x6.16) (SE) 66.0 X 0.0690 X 31.7 = 144 R-21 Wall (W. 19.2x6.16) (S) 137.5 X 0.0690 X 27.7 = 262 R-21 Wall (W.19.2x6.16) (W) 275.0 X 0.0690 X 32.3 = 614 R-21 Wall (W.19.2x6.16) (N) 196.0 X 0.0690 X 29.0 = 392 X X = X X = X X = Page Total 2,592 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (E) 0.0 X 19.7 + 6.0 X 35.8 = 215 Window (SE) 0.0 X 19.7 + 24.0 X 27.9 = 668 Window (S) 0.0 X 19.7 + 12.5 X 22.2 = 277 Window (tM 0.0 X 19.7 + 12.5 X 37.6 = 470 Window (W) 0.0 X 19.7 + 12.5 X 37.6 = 470 Window (N) 0.0 X 19.7 + 14.0 X 30.0 = 420 X + X = X + X = X + X - Page Total 2,520 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 25.12 X 42 = 1,050 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,392 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4.771 X 0.94 X 25.12 X 0.00523 = 587 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 787 EnergyPro 5.1 by EnercySoft User Number: 6712 RunCode: 2013-02-25717:27:14 ID: Pace 34 of 34 1:IT Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/25/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 2/26/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/25/2013 Project Address Traditions, Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor AreaAddition 4,65; n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction T e ` Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4, a is Barrier New Wall Wood Framed R-21 I 4M. .! LUT LAUUINTA I New WLJ Slab Unheated Slab -on -Grade None I 4,980 e R - DEPT. New Door Opaque Door None 1 24 New FOR CONSTRUC110N U Y FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (S) 200.5 0.390 0.32 none none Bug Screen New Right (VV) ��„ 217.0 0.390-.-i 0.32—none-, __r..,.none 1�..._....,. ,Bug Screens New Front (N) r j 63.4 0.89b 0.32 none • ± none Bug Screen New Left (E) 6141.2 0.390 0.32 none i none f Bug Screen New Rear (S)/ 190.0 ,f 0.390 0.32 15.0 % none Bug Screen New ' _ Right k _ � '% ( `; 60.3' "0.390 _ fry - 0.32 .10.0 none Y p Bug Screen ! k i f . ' a /. New Front (N) 72.0 1.190 0.59 4.0 none Bug Screen New Left (SE) 24.0 0.390 0.32 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 97% AFUE Split Air Conditioner 17.7 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Small Gas 50 0.80 All Pipes Ins New Ener Pro 5.1 by Energ Soft User Number. 6712 RunCode: 2013-02-25717:25:36 ID: Page 1 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 2/26/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 Project Address Traditions, Lot 14 La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 4,657 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 9796 AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status, HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25T17:25:36 ID: Pa 772 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: Ca10ERTS, Inc I Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 2/26/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RAa 3 must be met. HIGH MASS Design - Verity Thermal Mass: 773.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 360.0 R' Exposed Slab Floor, a 500" thick at Master Suite The HVAC System HVAC 2 & 3 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 260.0 ft2 Covered Slab Floor, 3.500" thick at GreabKitchen/Dining HIGH MASS Design -Verily Thermal Mass: 1,864.0 ft2 Exposed Slab Floor, 3.500" thick at GreabKitchen/Dining The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 534.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design -Verify Thermal Mass: 534.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4" HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4 The HVAC System HVAC 5 must serve only Sleeping Areas.` The non .closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the au flow requirements and fan watt draw requirements in�Residential A endix RA3.3 must be met. HIGH MASS Design - Verity Thermal Mass: 324.0 It Covered Slab Floor, 3.500" thick at Guest Suite HERS REQUIRE-D,VERIFICATION Items in thiscti seon require field testing'and/or verification by a certified HERS Rater: The'inspector=must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25T17:25:36 ID: Pace 3 of 9 Reg: 213-N0012230A-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 .Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 2/26/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5CF-1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alterati72/25/2013 Date SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 135.0 R= Exposed Slab Floor, 3.500" thick at Guest Suite The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIR_ ED ,VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater:-The'inspector-must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number. 6712 RunCode: 2013-02-25T17:25:36 ID: Pae 4 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: CalCERTS, Inc ho Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 2/26/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date West Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 1212512013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftp r Space Heating 4.61 3.41 1.19 Space Cooling 54.73 45.75 8.99 Fans 11.04 11.49 -0.46 Domestic Hot Water 7.83 6.40 1.43 Pumps 0.00 0.00 0.00 Totals 78.21 67.06 11.15 Percent Better Than Standard: 14.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 345 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 986 135 Fuel Available at Site: Natural Gas (E) 1,557 165 Raised Floor Area: 0 (S) 1,118 391 Slab on Grade Area: 4,960 Im 1,504 277 Average Ceiling Height: 11.5 Roof 4,657 0 Fenestration .Average U -Factor: 0.45 TOTAL: 968 Average SHGC: 0.34 Fenestration/CFA Ratio: 20.8% REMARKS 1k. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 2/25/2013 City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by ari approved HERS rater. Designer or Owner (per Business & Professions Code) Company Helton, DeFord 8 Associates Address 1261 N. Big Spring Street Name Jim Deford City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed License # Date Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25717:25:36 /D: Page 5 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: C'a10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 2/26/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12125/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,133 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Zone Wall 275 0.069 R-21 75 90 New 4.3.1-A6 Master Suite Zone Wall 157 0.069 R-21 165 90 New 4.3.1-A6 Master Suite Zone Wall 5341 0.069 R-21 255 90 New 4.3.1-A6 Master Suite Zone Wall 193 0.069 R-21 345 90 New 4.3.1-A6 Master Suite Zone Slab 773 0.730 None 0 180 New 4.4.7-A1 Master Suite Zone Slab 360 0.730 None 0. 180 New 4.4.7-A1 Master Suite Zone Roof 2,124 0.026 R-38 270 0 New 4.2.1-A9 Living Zone Wall 453 0.069 R-21 75 90 New 4.3.1 A6 Living Zone Wall 378 0.069 R-21 165 90 New 4.3.1 A6 Living Zone Wall 234 0.069 R-21 255 90 New 4.3.1-A6 Living Zone Wall 238 0.069 R-21 345 90 New 4.3.1-A6 Living Zone Door 24 0.500 None 345 90 New 4.5.1-A4 Living Zone Slab 260 0.730 None 0 180 New 4.4.7-A1 Livinq Zone Slab 1,864 0.730 1 None 01 180 New 14.4.7 -Al Living Zone Roof 632 0.026 R-38 1 1 1 2701 0 1 New 14.2.1-A9 Bedroom 2, 3 & 4 Zone FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 80.0 0.390 NFRC 0.32 NFRC 165 New Double Non -Metal Tinted Master Suite Zone 2 Window 18.0 0.390 NFRC 0.32 NFRC 165 New Double Non -Metal Tinted Master Suite Zone 3 Window 5.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 4 Window 5.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 5 Window -1-- 5.0 0.390 NFRC. 0.32 NFRC 255 New Double Non -Metal Tinted, ,w„ _ Master Suite Zone 6 Window N 12.5 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted' ! Master Suite Zone 7 Window ' 12.5 0.390 NFRC _ 0.32 NFRC 255 New Double Non -Metal Tinted " Master Suite Zone 8 Window 6.0 "0.390 NFRC 0.32 NFRC -1255 New Double Non -Metal Tinted Master Suite Zone 9 Window 12.0 10.390 NFRC 0.32 NFRC 1 255 New Double Non -Metal Tinted - Master. Suite Zone 10 Window ,/ /12.0 0.390 NFRC 0.32 NFRC ,255 New Double Non -Metal Tinted Master Suite Zone 11 Window,9 r ',, 12.0 0.390 NFRC • -0.32 NFRC -255 New ' . Double Non -Metal Tinted a,.- Master Suite Zone 12 Window 12.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 13 Window 12.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Master Suite Zone 14- Window 2.3 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Master Suite Zone 15 Window 2.3 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Master Suite Zone 16 Window 2.3 0.390 NFRC 0.32 NFRC 3451 New Double Non -Metal Tinted Master Suite Zone (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Len Hot I LExt RExt Dist Len Right Fin Hot Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 18ug Screen 0.76 . 16 18ug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25717:25:36 ID: Pae 6 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 Electronically Signed at Ca10ERTS.com by David -W Helton•(Helton, Deford &-Associates), 2/26/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name West Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 364 0.069 R-21 75 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Wall 55 0.069 R-21 165 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Wall 40 0.069 R-21 255 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Wall 1401 0.069 R-21 345 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Slab 534 0.730 None 0 180 New 4.4.7-A1 Bedroom 2, 3 & 4 Zone Slab 98 0.730 None 0 180 New 4.4.7-A1 Bedroom 2, 3 & 4 Zone Roof 309 0.026 R-38 270 0 New 4.2.1-A9 Bedroom 2, 3 & 4 Zone Wall 144 0.069 R-21 255 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Wall 60 0.069 R-21 345 90 New 4.3.1-A6 Bedroom 2, 3 & 4 Zone Slab 534 0.730 None 0 180 New 4.4.7-A1 Bedroom 2, 3 & 4 Zone Slab 98 0.730 None 0 180 New 4.4.7-A1 Bedroom 2, 3 & 4 Zone Roof 459 0.026 R-38 270 0 New 4.2.1-A9 Guest Suite Zone Wall 234 0.069 R-21 75 90 New 4.3.1-A6 Guest Suite Zone Wall 66 0.069 R-21 120 90 New 14.3.1-A6 IGuest Suite Zone Wall 138 0.069 R-21 165 90 New 14.3.1-A6 Guest Suite Zone Wall 275 0.069 R-21 I t 2551 901 New 14.3.1-A6 Guest Suite Zone FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 18 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 19 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 20 Window 2.3 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 21 Window -_ 20.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted _ _ Living Zone 22 Window 40.0 0.390 NFRC 0.32 NFRC 75 New "• Double Non -Metal Tinted' 1 Living Zone 23 Window *20.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Living Zone 24 Window 90.0 �: 0.390 NFRC 0.32 NFRC -,7165 New Double Non -Metal Tinted Living Zone 25 Window 190.0 10.390 NFRC 0.32 NFRC :' 165 New Double Non -Metal Tinted - Living Zone. �. 26 Window 4 f60.3 , 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Living Zone, T 27 WindowX z t 12.5 0.390 NFRC *0.32 NFRC 345 New '- Double Non-Metal•Tinted-<•- Living Zone --9,1 28 Window 32.0 1.190 NFRC 0.59 NFRC 345 New Custom Entry Door Living Zone 29 Window 40.0 1.190 NFRC 0.59 NFRC 345 New Custom Entty Door Living Zone 30 Window 8.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 31 Window 8.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom Z 3 & 4 Zone 32 Window 15.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom Z 3 & 4 Zone (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove rhan ' Left Fin Len Hot LExt RExt Dist Len Right Fin Hot Dist Len Hot 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 10.0 19.0 15.0 0.1 15.0 15.0 26 Bug Screen 0.76 9.0 6.7 10.0 0.1 10.0 10.0 27 Bug Screen 0.76 28 Bug Screen 0.76 8.0 4.0 4.0 0.1 4.0 4.0 29 _Bug Screen 0.76 10.0 4.0 4.01 0.1 4.0 4.0 30 Bug Screen 0.76 31 IBug Screen 0.76 32 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number. 6712 RunCode: 2013-02-25717:25:36 ID: Pae 7 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERT8.com - 2/25/2013 Electronically Signed at Ca10ERTS.com by David W Helton (Helton, De€ord & Associates). 2/26/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity 'Exterior -Frame Interior Frame- Azm Tilt -Status 4 Location/Comments Wall 196 0.069 R-21 345 90 New 4.3.1-A6 Guest Suite Zone Slab 324 0.730 None 0 180 New 4.4.7-A1 Guest Suite Zone Slab 135 0.730 None 0 180 New 4.4.7-A1 Guest Suite Zone FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 15.0 0.390 NFRC 0.32 NFRC 75 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 34 Window 15.0 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 35 Window 15.0 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 36 Window 20.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 37 Window ._ - 40.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 38 Window 20.0 0.390 NFRC .,'0.32 NFRC 255 New - Double Non -Metal Tinted' Bedroom 2, 3 & 4 Zone 39 Window 6.0 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Bedroom 2, 3 & 4 Zone 40 Window 6.0 70.390 NFRC 0.32 NFRC .-1 75 New Double Non -Metal Tinted Guest Suite Zone 41 Window 24.0 10.390 NFRC 0.32 NFRC V 120 New Double Non -Metal Tinted - Guest Suite Zone � 42 Window A /12.5 0.390 NFRC 0.32 NFRC ,165 New " Double Non -Metal Tinted Guest Suite Zone 43 Windows r: t 12.5 0.390 NFRC --0.32 NFRC ` .255 New •. Double Non -Metal Tinted4-- Guest Suite Zone) 44 Window 12.5 0.390 NFRC 0.32 NFRC 255 New Double Non -Metal Tinted Guest Suite Zone 45 Window 14.0 0.390 NFRC 0.32 NFRC 345 New Double Non -Metal Tinted Guest Suite Zone -U ?T ) -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Len Hclt LExt RExt Dist Len Ri ht Fin H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 'Bug Screen 0:76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25717:25:36 /D: Pae 8 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/25/2013 Electronically Signed at CalCERTS.com by David w Helton (Helton, Deford & Associates) 2/26/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name West Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Master Suite 1,133 1Z236 HVAC 2 & 3 Great/Kitchen/Dining 2,124 27,187 HVAC 4 Bedroom 2 & 3 632 6,320 Bedroom 4 309 3,090 HVAC 5 Guest Suite 459 4,590 Totals 4,657 01 01 0 HVAC SYSTEMS . System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 97% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 4 r a 1 Central Furnace ; 97% AFUE Split Air Conditioner ~-- :. 17.7 SEER Setback New HVAC 5,,"',,' 1 i Cental Furnace !' 97% AFUE Split Air Condition&r i 16.5 SEER Setback New V At HVAC DISTRIBUTION -t rf 1 ; r . _ i System Name Heating —'Duct,. C - Ducts': Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 5 Ducted Ducted I Attic, Ceiling Ins, vented 8.01 m 1 New 13 WATER HEATING SYSTEMS Sstem Name Q T e Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Bradford -White 50 Gal 2 Small Gas All Pipes Ins 40 50 0.80 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) 0 m 0 a System Name Pipe Length Pipe Diameter Insul. Thick. Qt .HP Plenum Outside Buried 13 ❑ Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-02-25Ti7:25:36 ID: Pae 9 of 9 Reg: 213-NO01223OA-000000000-0000 Registration Date/Time: 2013/02/25 22:56:04 HERS Provider: CalCERTS, Inc