Loading...
10-0703 (SFD) Title 24P W K I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Traditions Lot 8 Lot 8 La Quinta, CA 92260 Project Designer: Jim Deford Design & Drafting 24-686 Venabio Mission Viejo, Ca 92691 (949) 831-0313 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive 0 � Palm Desert, Ca 92211 0h (760) 200-4786:` CITY OF LA QU.jNTA"- " BUILDING & SAFETY DEPS: APPROVED A! FOR CONSTRUCTION f ' WE �� �� Z� D BY Job Number: -7 Date: 10/11/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. ti EnemvPro 5.1 by EnerovSoR User Number: 6712 RunCode: 2010-10-11713.43:59 /D: C� J C PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/11/2010 Project Address Lot 8 La Quinta California Energy Climate ZonTotal CA Climate Zone 151 Cond. Floor Area 4,246 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,246 Ext=R-7.0 Radiant Barrier New Wall Wood Framed R-21 3,443 New Slab Unheated Slab -on -Grade None 4,246 Perim = 423' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (S) 299.8 0.390 0.39 none none Bug Screen New Front (1/1,9 381.0 0.390 0.39 none none Bug Screen New Rear (E) 115.5 0.390 0.39 none none Bug Screen New Left (N) 119.3 0.390 0.39 none none Bug Screen New Front (NIAq 24.0 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.99 All Pipes Ins New I EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2010-10-11T13:43:59 ID: Page 3 of 35 LJ • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11011112010 Date Project Address Lot 8 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,246 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-11T13:43:59 /D: Page 4 of 35 • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/11/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White EF -100T -150-3N is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 615.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1 Owners Suite HIGH MASS Design - Verify Thermal Mass: 362.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Owners Suite The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 222.0 ft2 Covered Slab Floor, 3.500" thick at Zone 2 Living, Kitchen & Nook HIGH MASS Design - Verify Thermal Mass: 1, 797.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 2 Living, Kitchen & Nook The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan waft draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 466.0 ft2 Covered Slab Floor, 3.500" thick at Zone 3 Bedroom 2, 3 & 4 HIGH MASS Design - Verify Thermal Mass: 362.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 3 Bedroom 2, 3 & 4 The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 292.0 ft2 Covered Slab Floor, 3.500" thick at Zone 4 Casita HIGH MASS Design - Verify Thermal Mass: 130.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 4 Casita HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA424158CVX071 includes credit for a 11.2 EER Condenser. A certified HERS rater must Field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS Field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-11T13:43:59 ID: Page 5 of 35 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 10/11/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.204.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a com leted CF -4R form for each of the measures listed below for final to be given. EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11T13.43:59 ID: Pa - e 6 of 35 C PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Traditions Lot 8 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 110/111201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.73 2.13 1.60 Space Cooling 62.16 63.18 -1.02 Fans 12.78 16.70 -3.92 Domestic Hot Water 8.59 4.67 3.92 Pumps 0.00 0.00 0.00 Totals 87.26 86.68 0.58 Percent Better Than Standard: 1 0.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (vv) 896 405 Fuel Available at Site: Natural Gas (N) 1,288 119 Raised Floor Area: 0 (E) 873 116 Slab on Grade Area: 4,246 (S) 1,350 300 Average Ceiling Height: 10.7 Roof 4,246 0 Fenestration Average U -Factor: 0.39 TOTAL: 940 Average SHGC: 0.39 Fenestration/CFA Ratio: 22.1% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Inc,Scott Design and Title 24, �' Company 10/11/2010 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Jim Deford Design & Drafting Address 24-686 Venabio Name Jim Deford City/State/Zip Mission Viejo, Ca 92691 Phone (949) 831-0313 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11713:43:59 /D: Page 7 of 35 • r--1 L --A • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Traditions Lot 8 Building Type m Single Family O Addition Alone 1 O Multi Family O Existing+ Addition/Alteration Date 0/11/201 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 977 0.022 R-38 7.0 None 180 20 New 4.2.1-A9 Zone 1 Owners Suite Wall 539 0.069 R-21 160 90 New 4.3.1-A6 Zone 1 Owners Suite Wall 80 0.069 R-21 250 90 New 4.3.1-A6 Zone 1 Owners Suite Wall 275 0.069 R-21 340 90 New 4.3.1-A6 Zone 1 Owners Suite Wall 130 0.069 R-21 70 90 New 4.3.1-A6 Zone 1 Owners Suite Slab 615 0.730 None 0 180 New 4.4.7-A1 Zone 1 Owners Suite Slab 362 0.730 None 0 180 New 4.4.7-A1 Zone 1 Owners Suite Roof 2,019 0.022 R-38 7.0 None 180 20 New 4.2.1-A9 Zone 2 Living, Kitchen & N Wall 184 0.069 R-21 70 90 New 4.3.1-A6 Zone 2 Livin ,Kitchen & N Wall 120 0.069 R-21 160 90 New 4.3.1-A6 Zone 2 Living,Kitchen & N Wall 246 0.069 R-21 250 90 New 4.3.1-A6 Zone 2 Living,Kitchen & N Wall 388 0.069 R-21 340 90 New 4.3.1-A6 Zone 2 Livin ,Kitchen & N Slab 222 0.730 None 0 180 New 4.4.7-A1 Zone 2 Livin ,Kitchen & N Slab 1 11797 0.730 None 0 180 New 4.4.7-A1 Zone 2 Livin ,Kitchen & N Roof 1 828 0.022.R-38 7.0 None 180 20 New 4.2.1-A9 lZone 3 Bedroom 2, 3 & 4 Wall 1 3081 0.069 R-21 1 340 90 New 14.3.1-A6 JZone 3 Bedroom 2, 3 & 4 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 12.5 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 2 Window 12.5 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 3 Window 12.5 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 4 Window 6.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 5 Window 6.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 6 Window 12.5 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 7 Window 11.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 8 Window 12.5 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 9 Window 11.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 10 Window 5.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 11 Window 5.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 12 Window 5.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 1 Owners Suite 13 Window 80.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 1 Owners Suite 14 Window 12.0 40.390 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 15 Window 32.0 0.390 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 16 Window 12.0 0.390 NFRC 0.39 NFRC 70 New Architectural Traditions Wndow4 Zone 2 Living, Kitchen & Nook (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen - 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5. 1 by EnergySoft User Number 6712 RunCode: 2010-10-11 T13:43:59 ID: Page 8 of 35 C � J CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 0/11/201 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 302 0.069 R-21 70 90 New 4.3.1-A6 Zone 3 Bedroom 2, 3 & 4 Door 24 0.500 None 70 90 New 4.5.1-A4 Zone 3 Bedroom 2, 3 & 4 Wall 144 0.069,R-21 160 90 New 4.3.1-A6 Zone 3 Bedroom 2, 3 & 4 Wall 20 0.069 R-21 250 90 New 4.3.1-A6 Zone 3 Bedroom 2, 3 & 4 Slab 466 0.730 None 0 180 New 4.4.7-A1 Zone 3 Bedroom 2, 3 & 4 Slab 362 0.730 None 0 180 New 4.4.7-A1 Zone 3 Bedroom 2, 3 & 4 Roof 422 0.022 R-38 7.0 None 180 20 New 4.2.1-A9 Zone 4 Casita Wall 198 0.069 R-21 340 90 New 4.3.1-A6 Zone 4 Casita Wall 118 0.069 R-21 70 90 New 4.3.1-A6 Zone 4 Casita Wall 248 0.069 R-21 160 90 New 14.3.1-A6 Zone 4 Casita Wall 79 0.069 R-21 250 90 New 14.3.1-A6 Zone 4 Casita Wall 66 0.069 R-21 295 90 New 4.3.1-A6 Zone 4 Casita Slab 292 0.730 None 0 180 New 4.4.7-A1 Zone 4 Casita Slab 130 0.730 None 0 180 New 4.4.7-A1 Zone 4 Casita FENESTRATION SURFACE DETAILS ID Type Area ' U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 12.5 0.390 1 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 18 Window 60.3 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 19 Window 190.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 2 Living, Kitchen & Nook 20 Window 90.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 21 Window 2.3 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 22 Window 2.3 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 2 Living, Kitchen & Nook 23 Window 2.3 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 24 Window 2.3 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 25 Window 2.3 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 26 Window 2.3 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 2 Living,Kitchen & Nook 27 Window 15.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 28 Window 15.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 29 Window 8.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 30 Window 8.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 31 Window 7.5 0.390 NFRC 0.39 NFRC 3401 New Architectural Traditions Window one 3 Bedroom Z 3 & 4' 32 Window 12.5 0.390 NFRC 0.39 NFRC 3401 New Architectural Traditions Windowl Zone 3 Bedroom 2, 3 & 4 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hot Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 113ug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-11T13:43:59 ID: Page 9 of 35 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 0/11/201 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 12.5 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 34 Window 6.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 35 Window 20.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 36 Window 40.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 37 Window 20.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4 38 Window 10.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 4 Casita 39 Window 11.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 4 Casita 40 Window 6.0 0.390 NFRC 0.39 NFRC 340 New Architectural Traditions Window Zone 4 Casita 41 Window 12.5 0.390 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 4 Casita 42 Window 11.0 0.390 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 4 Casita 43 Window 12.5 0.390 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 4 Casita 44 Window 11.0 0.390 NFRC 0.39 NFRC 70 New Architectural Traditions Window Zone 4 Casita 45 Window 10.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 4 Casita 46 Window 11.0 0.390 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 4 Casita 47 Window 10.0 0.3901 NFRC 0.39 NFRC 160 New Architectural Traditions Window Zone 4 Casita 48 Window 11.0 0.390 NFRC 0.39 1 NFRC 160 New Architectural Traditions Windowl Zone 4 Casita (1) 1.1 -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 1Bug, Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 IBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-11713:43:59 /D: Pae 10 of 35 • L] C , J CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 0/11/201 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 10.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 4 Casita 50 Window 11.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 4 Casita 51 Window 24.0 0.390 NFRC 0.39 NFRC 295 New Architectural Traditions Window Zone 4 Casita (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt REA Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-11713.43:59 ID: Pae 11 of 35 • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Traditions Lot 8 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11011112016 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Zone 1 Owners Suite 977 10,747 HVAC 2 & 3 Zone 2 Living, Kitchen & Nook 2,019 22,209 HVAC 4 Zone 3 Bedroom Z 3& 4 828 8,280 HVAC 5 Zone 4 Casita 422 4,220 Totals 4,246 0 0 0 HVAC SYSTEMS System Name Qt . HeatingType Min. Eff. CoolingType Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 p New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 1 4.21 lNew HVAC 5 Ducted I Ducted JAttic, Ceiling Ins, vented 4.21 INew WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White EF -100T- 1 Large Gas All Pipes Ins 150,000 100 0.99 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E 7 m w a Hot Water Piping Length ft o a — System Name Pipe Length Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5. 1 by EnemySoft User Number. 6712 RunCode: 2010.10-11713:43:59 ID: Pae 12 of 35 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name raditions Lot 8 Date 11011112010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: e 1 A: Mason or factory -built fireplaces have a closable metal or lass door coveringthe entire opening of the firebox. (e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is El ed with a with a readil accessible, o erable, and ti ht-fittin dam er and or a combustion -air control device. (e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the de of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-11T13:43:59 ID: Page 13 of 35 r i� 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Traditions Lot 8 11011112010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-10-11713:43:59 ID: Page 14 of 35 4 ANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R ject Name r Date ditionss Lot 8 11011112010 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number. 6712 Run Code: 2010-10-11713:43:59 ID: Page 15 of 35 r i� 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name raditions Lot 8 Date 10/11/2010 System Name HVAC 1 Floor Area 977 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 720 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 14,445 2,049 332 14,303 Total Output Stuh 71,000 0 Output Btuh/s ft 72.7 1,043 1,016 Cooling System 0 0 Output per System 47,500 0 0 0 0 Total Output Btuh 47,500 0 2,0491 0 Total Output Tons 4.0 1,043 1,016 Total Output Btuh/s ft 48.6 Total Output s ftlron 246.8 16,532 1 16,335 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ACA448/58CVX090 34,185 3,741 71,000 71,000 I Jan 1 AM Airflow cfm/s ft 1.64 Airflow cfm/Ton 404.2 Outside Air % 0.0% Total Adjusted System Output 34,185 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,741 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 113 OF 113 OF i (�] r' Heating Coil Supply Fan 1,600 cfm 113 OF i ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71/58°F 4 Ar . 71/58°F 51/50°F 51/50°F Cooling Coil Supply Fan 51 / 50 OF 1,600 cfm:............_.._.............. ......._..M 48.2% ROOM _ 70/58°F 4 3 4 1 EnergyPro 5.1 by EnergySofi User Number. 6712 RunCode: 2010-10-11 T13:43:59 ID: Page 16 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name raditions Lot 8 Date 10/11/2010 System Name HVAC 2 & 3 Floor Area 2,019 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,416 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 28,670 3,380 504 21,865 Total Output Btuh 142,000 0 2,071 0 Output Btuh/s ft 70.3 1,553 Cooling System 0 Output perSystem 47,500 0 0 0 0 Total Output Btuh 95,000 0 2,071 1 32,8121 3,3801 0 Total Output Tons 7.9 1,553 Total Output Btuh/s ft 47.1 Total Output s ft/Ton 255.0 1 24,971 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 24ACA448/58CVX090 68,941 6,708 142,000 142,000 Jan 1 AM Airflow cfm/s ft 1.58 Airflow cfm/Ton 404.2 Outside Air % 0.0% Total Adjusted System Output 68,941 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 6,708 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF / 10 Outside Air 0 cfm 72 OF -d 914 72 OF 113 OF 113 OF Heating Coil Supply Fan o 3,200 cfm 113 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside AirNO: 0 cfm 71/58°F 71/58°F 50/49°F 50/49°F Cooling Coil Supply Fan 51 / 50 OF 3.200 cfm _........_.._ _................. 47.6% ROOM 70/58°F EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2010.10-11T13.43:59 /D: Page 17 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Traditions Lot 8 Date 10/11/2010 System Name HVAC 4 Floor Area 828 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 610 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 12,395 1,858 279 12,100 Total Output Btuh 71,000 0 Output Btuh/s ft 85.7 895 860 Cooling System 0 0 Output perSystem 47,500 0 0 0 0 Total Output Btuh 47,500 0 895 14,186 1,858 0 Total Output Tons 4.0 860 Total Output Btuh/s ft 57.4 Total Output s ft/Ton 209.2 13,819 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24AGA448/58CVX090 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 34,308 3,529 71,000 34,308 3,529 71,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 1.93 Airflow cfm/Ton 404.2 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4 V- 0 cfm 71 OF 71 OF 113 OF 113 OF M Heating Coil Supply Fan 1,600 cfm 113 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm • 71/58°F 4 AV 1 71/58°F 50/49°F 50/49°F Cooling Coil Supply Fan 1,600 cfm. — — 3 4 51 / 50 OF _..... ._.._.. ,, 47.8% R ! OOM 70/58°F 1 EnergYPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-11 T13:43:59 ID: Page 18 of 35 r L_ HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name raditions Lot 8 Date 10/11/2010 System Name HVAC 5 Floor Area 422 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 611 11,282 Return Vented Lighting 0 Return Air Ducts 815 Return Fan o Ventilation 0 0 Supply Fan 0 Supply Air Ducts 815 TOTAL SYSTEM LOAD 1 12,912 COIL HTG. Latent CFM 1,339 154 0 0 1,339 PEAK Heating System Sensible Output perSystem 51,000 9,581 Total Output Btuh 51,000 Output Btuh/s ft 120.9 681 Cooling System 0 Output perSystem 23,500 0 Total Output Btuh 23,500 0 Total Output ons 2.0 681 Total Output Btuh/s ft 55.7 Total Output s ft/Ton 215.5 10,943 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24ACA424/58CVX071 16,400 2,611 51,000 Airflow cfm/s ft 1.90 Airflow cfm/Ton 408.5 51,000 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 16,400 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 2,611 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 131 OF 131 OF Heating Coil Supply Fan o 800 cfm 130 F ROOM in 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air -4,- 0 cfm 71/59°F 71/59°F 52/51°F 52/51°F ------- IF a Cooling Coil Supply Fan 800 cfm 51.0% 53 / 51 OF _.....___............__.._..__..._. , � ROOM 70/59°F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-11713:43:59 /D: Page 19 of 35 • • • ROOM LOAD SUMMARY Project Name Date Traditions Lot 8 10/11/2010 HVAC 2 & 3 1 2,019 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 2 Living, Kitchen & No Zone 2 Living, Kitchen & 1 1,416 28,670 3,380 1,416 28,670 3,380 504 21,865 Total includes ventilation load for zonal PAGE TOTAL TOTAL" 1,416 28,670 3,380 504 21,865 1,416 28,670 3,380 504 21,865 • • ROOM LOAD SUMMARY Project Name Date Traditions Lot 8 10/11/2010 System Name Floor Area HVAC 4 828 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 3 Bedroom 2, 3 & 4 Zone 3 Bedroom Z 3 & 4 1 1 6101 1Z3951 1,858 610 1Z3951 1,8581 2791 12,100 PAGE TOTAL TOTAL 610 12,395 1,858 279 12,100 610 12,395 1,858 279 12,100 • �11 • ROOM LOAD SUMMARY Project Name Date Traditions Lot 8 10/11/2010 System Name Floor Area HVAC 5 422 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 4 Casita Zone 4 Casita 1 611 11,282 1,339 6111 11,2821 1,339 1541 9,581 PAGE TOTAL TOTAL' 611 11,282 1,339 154 9,58 611 11,2821 1,3391 154 9,5R] • ROOM HEATING PEAK LOADS Project Name Traditions Lot 8 Date 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Owners Suite Floor Area 977.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0220 X 0.0690 X 0.3900 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 11.00 X 0.289 Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 977.0 46 989 R-21 Wall (W.19.2x6.16) 1,023.5 46 3,249 Architectural Traditions Windows 191.5 46 3,436 Slab -On -Grade perim = 122.0 46 4,097 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interior surface X 977 X Area Page Total /60] X AT 1 11,769 = 2,533 TOTAL HOURLY HEAT LOSS FOR ROOM 14,303 Energ Pro 5.1 by Energ Soft User Number., 6712 RunCode: 2010-10-11T13.43:59 /D: Page 24 of 35 r� U L� ROOM HEATING PEAK LOADS Project Name Traditions Lot 8 Date 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 2 Living, Kitchen & Nook Floor Area 2,019.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 0.0220 X 0.0690 X 0.3900 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X another room 11.00 X 0.289 Height ACH AT °F _ c a = o = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 2,019.0 X X X 46 2,043 R-21 Wall (W.19.2x6.16) 937.4 46 2,975 Architectural Traditions Windows 422.6 46 7,581 Slab -On -Grade perim = 120.0 X 46 4,030 X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to 1.064 X 2,019 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction Page Total /60] X AT 16,629 = 5,235 TOTAL HOURLY HEAT LOSS FOR ROOM 21,865 Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2010-10-11713.43:59 /D: Page 25 of 35 • ROOM HEATING PEAK LOADS Project Name Traditions Lot 8 Date 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 Bedroom 2, 3 & 4 Floor Area 828.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction . Area U -Value X 0.0220 X 0.0690 X 0.3900 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 828.0 46 838 R-21 Wall (W.19.2x6.16) 773.5 46 2,455 Architectural Traditions Windows 164.5 46 2,951 Wood Door 24.0 X 0.5000 46 552 Slab -On -Grade perim = 94.0 X X X 0.7300 46 3,157 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 828 X Area to another room 10.00 X 0.318 Ceiling Height ACH Page Total /60] X AT 9,953 = 2,147 TOTAL HOURLY HEAT LOSS FOR ROOM 12,100 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2010-10-11713:43:59 /D: Page 26 of 35 C ROOM HEATING PEAK LOADS Project Name710/11/2010 Traditions Lot 8 ate ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 4 Casita Floor Area 422.0 ft2 Indoor Dry Bulb Tem erature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 422.0 X 709.0 X 161.0 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr R-38 Roof(R.38.2x14.16) 0.0220 46 c = = c = = 427 R-21 Wall (W.19.2x6.16) 0.0690 46 2,250 Architectural Traditions Windows 0.3900 46 2,888 Slab -On -Grade perim = 87.0 X X X 0.7300 46 2,921 X = = X X = = X X = X X X X X = = = = X X = = = X X X X X = = = = X = X = = X X X X = = = X X through an interior surface to X 422 X Area Ceiling = = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 10.00 X 0.318 Height ACH Page Total /60] X 46 AT 8,487 = 1,094 TOTAL HOURLY HEAT LOSS FOR ROOM 9,581 Energ Pro 5.1 by Energ Soft User Number. 6712 Run Code: 2010-10-11713:43:59 /D: Page 27 of 35 J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Traditions Lot 8 1 10/11/2010 Room Name Zone 1 Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 977.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temaerature 70 OF I Outdoor Dally Ranae: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) I Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 977.0 0.0220 56.0 538.5 0.0690 28.2 80.0 0.0690 32.1 275.01 0.0690 29.0 130.0 0.0690 31.2 22.3 6.0 26.3 0.0 22.3 6.0 26.3 0.0 22.3 12.5 26.3 0.0 22.3 11.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 1 2 3 4 5 6 7 8 9 Orientation (S) (S) (S) (S) (S) (S) (S) (S) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 22.3 12.5 26.3 0.0 22.3 12.5 26.3 0.0 22.3 12.5 26.3 0.0 22.3 6.0 26.3 0.0 22.3 6.0 26.3 0.0 22.3 12.5 26.3 0.0 22.3 11.0 26.3 0.0 22.3 12.5 26.3 0.0 22.3 11.0 26.3 Page Total Btu/hr 1,203 1,049 177 550 280 3, Btu/hr 329 329 329 158 158 329 289 329 289 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 )( 0.94 X 53.46 X 42 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14.4451 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 53.46 X 0.00523 = 1,249 Air Sensible CFM ELA AW 101 TOTAL HOURL r: • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Traditions Lot 8 1 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 977.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 1 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10 (S) 0.0 X 22.3 + 5.0 X 26.3 = 132 11 (S) 0.0 X 22.3 + 5.0 X 26.3 = 132 12 (S) 0.0 X 22.3 + 5.0 X 26.3 = 132 13 (tM 0.0 X 22.3 + 80.0 X 43.7 = 3,497 X + X = X + X - X + X - X + X = X + X - Page Total 1 3,892 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 53.46 X 42 = 2,235 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,445 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 53.46 X 0.00523 = 1,249 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,049 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11T13:43:59 ID: Page 29 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Traditions Lot 8 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 2 Living, Kitchen & Nook Outdoor Dry Bulb Temperature Floor Area 2,019.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) I Orientation (S) (S)i Date 10/11/2010 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,019.0 0.0220 56.0 183.5 0.0690 31.2 119.7 0.0690 28.2 246.01 0.0690 32.1 388.2 0.0690 29.0 22.3 12.5 40.7 0.0 22.3 60.3 26.3 0.0 22.3 190.0 43.7 0.0 22.3 90.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 14 15 16 17 18 19 20 21 22 Orientation (E) (E) (E) (E) (S) (149 (►M (N) (N) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 22.3 12.0 40.7 0.0 22.3 32.0 40.7 0.0 22.3 12.0 40.7 0.0 22.3 12.5 40.7 0.0 22.3 60.3 26.3 0.0 22.3 190.0 43.7 0.0 22.3 90.0 43.7 0.0 22.3 2.3 34.8 0.0 22.3 2.3 34.8 Page Total 112 OF 78 OF 34 OF Btu/hr 2,487 395 233 545 4, Btu/hr 489 1,303 489 509 1,587 8,305 3,934 80 80 16, 775 Internal Gain Btu/hr Occupants 4.0 Occupants X230 Btuh/occ. ` Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 )( 0.94 X 110.48 X Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,6701 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 110.48 X 0.00523 = 2,580 Air Sensible CFM ELA AW 101 TOTAL HOURLY LATENT HEAT I -J • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Traditions Lot 8 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 2 Living, Kitchen & Nook Outdoor Dry Bulb Temperature 112 OF Floor Area 2,019.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 23 (IV) 0.0 X 22.3 + 2.3 X 34.8 = 80 24 (N) 0.0 X 22.3 + 2.3 X 34.8 = 80 25 (N) 0.0 X 22.3 + 2.3 X 34.8 = 80 26 (N) 0.0 X 22.3 + 2.3 X 34.8 = 80 X + X - X + X - X + X - X + X - X + X - Page Total 1 320 Internal Gain Btu/hr Occupants 4.0 Occupants X 1 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 110.48 X 42 = 4,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,670 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 110.48 X 0.00523 = 2,580 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,380 EnemyPro 5.1 by EnemySoft User Number. 6712 RunCode: 2010-10-11713:43:59 /D: Page 31 of 35 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Traditions Lot 8 --710/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 Bedroom 2, 3 & 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 828.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Wood Door R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) Orientation (E) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = c = c = 828.0 0.0220 56.0 307.5 0.0690 29.0 302.0 0.0690 31.2 24.0 0.5000 31.2 144.0 0.0690 28.2 20.0 0.0690 32.1 0.01 22.3 7.5 34.8 0.0 22.3 12.5 J 0.0 22.3 12.5 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanactratinn 27 28 29 30 31 32 33 34 35 Internal Gain Orientation (N) (N) (N) (N) (N) (N) (N) (S) (S) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = c 0 = = = = = 0.0 22.3 15.0 34.8 0.0 22.3 15.0 34.8 0.0 22.3 8.0 34.8 0.0 22.3 8.0 34.8 0.01 22.3 7.5 34.8 0.0 22.3 12.5 34.8 0.0 22.3 12.5 34.8 0.0 22.3 6.0 26.3 0.0 22.3 20.0 26.3 4.0 Occupants X 230 Btuh/occ. 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.94 X 45.31 X 42 = Air Sensible CFM ELA AT Page Total Btu/hr 1,020 615 651 280 2, Btu/hr 522 522 279 279 261 435 435 158 526 3,417 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,3951 Latent Gain 4.0 Occupants X 200 Btuh/occ. Btu/hr c 800 Infiltration: 4,771 X 0.94 X 45.31 X 0.00523 = 1,058 Air Sensible CFM ELA AW . TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,858 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Traditions Lot 8 1 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 Bedroom 2, 3 & 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 828.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 36 (S) 0.0 X 22.3 + 40.0 X 26.3 = 1,053 37 (S) 0.0 X 22.3 + 20.0 X 26.3 = 526 X + X = X + X — X + X - X + X - X + X = X + X - X + X - Page Total 1,579 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = E920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 45.31 X 42 = 1,894 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,395 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 45.31 X 0.00523 = 1,058 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,858 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11T13:43:59 ID: Page 33 of 35 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Traditions Lot 8 ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temper. Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W..19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (IN. 19.2x6.16) R-21 Wall (W. 19.216.16) Orientation Zone 4 Casita Outdoor Dry Bulb Temperature 422.0 ft2 Outdoor Wet Bulb Temperature 70 OF I Outdoor Dailv Ranae: (S) z Date 10/11/2010 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 422.0 0.0220 56.0 198.0 0.0690 29.0 118.0 0.0690 31.2 248.0 0.0690 28.2 79.0 0.0690 32.1 66.0 0.0690 31.5 0.0 22.3 11.0 40.7 0.0 22.3 12.5 40.7 0.0 22.3 11.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 38 X X X X X X X X X 39 + + + + + + + + + 40 41 X X X X X X X X X 42 = = = = = = = = = 43 22.3 44 34.8 45 22.3 46 34.8 Orientation (N) (N) (N) (E) (E) (E) (E) (S) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 22.3 10.0 34.8 0.0 22.3 11.0 34.8 0.0 22.3 6.0 34.8 0.0 22.3 12.5 40.7 0.0 22.3 11.0 40.7 0.0 22.3 12.5 40.7 0.0 22.3 11.0 40.7 0.0 22.3 10.0 26.3 0.0 22.3 11.0 26.3 Page Total 112 OF 78 OF 34 OF Btu/hr 520 396 254 483 175 143 Btu/hr 348 383 209 509 448 509 448 263 289 3,406 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu 1,600 Infiltration: 1.064 X 0.94 X 23.09 X 42 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11.2821 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 23.09 X 0.00523 = 539 Air Sensible CFM ELA AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Traditions Lot 8 1 10/11/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 4 Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 422.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X X X = X X = X X = X X = X X = Page Total 1 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 47 (S) 0.0 X 22.3 + 10.0 X 26.3 = 263 48 (S) 0.0 X 22.3 + 11.0 X 26.3 = 289 49 (W) 0.0 X 22.3 + 10.0 X 43.7 = 437 50 (1/109 0.0 X 22.3 + 11.0 X 43.7 = 481 51 (NVIvq 0.0 X 22.3 + 24.0 X 39.5 = 949 X + X = X + X = X + X = X + X = Page Total 2,419 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 23.09 X 42 = 965 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,282 Latent Gain Btu/hr Occupants 4.0 � Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 23.09 X 0.00523 = 539 Air Sensible CFM EL A AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,339 EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2010-10-11713:43:59 ID: Pa - e 35 of 35