10-0703 (SFD) Title 24P
W
K
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Traditions Lot 8
Lot 8
La Quinta, CA 92260
Project Designer:
Jim Deford Design & Drafting
24-686 Venabio
Mission Viejo, Ca 92691
(949) 831-0313
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive 0 �
Palm Desert, Ca 92211 0h
(760) 200-4786:` CITY OF LA QU.jNTA"-
"
BUILDING & SAFETY DEPS:
APPROVED
A! FOR CONSTRUCTION f '
WE �� �� Z� D BY
Job Number: -7
Date:
10/11/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
ti
EnemvPro 5.1 by EnerovSoR User Number: 6712 RunCode: 2010-10-11713.43:59 /D:
C�
J
C
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
10/11/2010
Project Address
Lot 8 La Quinta
California Energy Climate ZonTotal
CA Climate Zone 151
Cond. Floor Area
4,246
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 4,246 Ext=R-7.0 Radiant Barrier New
Wall Wood Framed
R-21 3,443 New
Slab Unheated Slab -on -Grade
None 4,246 Perim = 423' New
Door Opaque Door
None 24 New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (S) 299.8 0.390
0.39 none none Bug Screen New
Front (1/1,9 381.0 0.390
0.39 none none Bug Screen New
Rear (E) 115.5 0.390
0.39 none none Bug Screen
New
Left (N) 119.3 0.390
0.39 none none Bug Screen
New
Front (NIAq 24.0 0.390
0.39 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 14.0 SEER Setback
New
2 Central Furnace 80% AFUE
Split Air Conditioner 14.0 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 14.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
New
HVAC 2 & 3 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
New
HVAC 4 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Large Gas 100
0.99 All Pipes Ins
New
I
EnergyPro 5.1 by EnergySoft User Number: 6712
Run Code: 2010-10-11T13:43:59 ID:
Page 3 of 35
LJ
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 11011112010
Date
Project Address
Lot 8 La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,246
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 4.2
New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-11T13:43:59 /D:
Page 4 of 35
•
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
10/11/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Bradford -White EF -100T -150-3N is a non-NAECA large storage gas water heater. Verify DHW details.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be
controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met.
HIGH MASS Design - Verify Thermal Mass: 615.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1 Owners Suite
HIGH MASS Design - Verify Thermal Mass: 362.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Owners Suite
The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be
controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met.
HIGH MASS Design - Verify Thermal Mass: 222.0 ft2 Covered Slab Floor, 3.500" thick at Zone 2 Living, Kitchen & Nook
HIGH MASS Design - Verify Thermal Mass: 1, 797.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 2 Living, Kitchen & Nook
The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be
controlled with a separate thermostat. In addition the air flow requirements and fan waft draw requirements in Residential Appendix RA -6 must be met.
HIGH MASS Design - Verify Thermal Mass: 466.0 ft2 Covered Slab Floor, 3.500" thick at Zone 3 Bedroom 2, 3 & 4
HIGH MASS Design - Verify Thermal Mass: 362.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 3 Bedroom 2, 3 & 4
The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be
controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met.
HIGH MASS Design - Verify Thermal Mass: 292.0 ft2 Covered Slab Floor, 3.500" thick at Zone 4 Casita
HIGH MASS Design - Verify Thermal Mass: 130.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 4 Casita
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Carrier 24ACA448158CVX090 includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ACA448158CVX090 includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ACA448158CVX090 includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ACA424158CVX071 includes credit for a 11.2 EER Condenser. A certified HERS rater must Field verify the installation
of the correct Condenser.
The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS Field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-11T13:43:59 ID: Page 5 of 35
•
•
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
I Date
10/11/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof(R.38.204.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
com leted CF -4R form for each of the measures listed below for final to be given.
EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11T13.43:59 ID: Pa - e 6 of 35
C
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Traditions Lot 8
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
110/111201
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 3.73 2.13 1.60
Space Cooling 62.16 63.18 -1.02
Fans 12.78 16.70 -3.92
Domestic Hot Water 8.59 4.67 3.92
Pumps 0.00 0.00 0.00
Totals 87.26 86.68 0.58
Percent Better Than Standard: 1 0.7%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (vv) 896 405
Fuel Available at Site: Natural Gas (N) 1,288 119
Raised Floor Area: 0 (E) 873 116
Slab on Grade Area: 4,246 (S) 1,350 300
Average Ceiling Height: 10.7 Roof 4,246 0
Fenestration Average U -Factor: 0.39 TOTAL: 940
Average SHGC: 0.39 Fenestration/CFA Ratio: 22.1%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Inc,Scott Design and Title 24, �'
Company 10/11/2010
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Jim Deford Design & Drafting
Address 24-686 Venabio Name Jim Deford
City/State/Zip Mission Viejo, Ca 92691 Phone (949) 831-0313 Signed License # Date
EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11713:43:59 /D: Page 7 of 35
•
r--1
L --A
•
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family O Addition Alone
1 O Multi Family O Existing+ Addition/Alteration
Date
0/11/201
OPAQUE SURFACE DETAILS
Surface
Type Area
U Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
977
0.022 R-38 7.0
None
180
20 New 4.2.1-A9 Zone 1 Owners Suite
Wall
539
0.069 R-21
160
90 New 4.3.1-A6 Zone 1 Owners Suite
Wall
80
0.069 R-21
250
90 New 4.3.1-A6 Zone 1 Owners Suite
Wall
275
0.069 R-21
340
90 New 4.3.1-A6 Zone 1 Owners Suite
Wall
130
0.069 R-21
70
90 New 4.3.1-A6 Zone 1 Owners Suite
Slab
615
0.730 None
0
180 New 4.4.7-A1 Zone 1 Owners Suite
Slab
362
0.730 None
0
180 New 4.4.7-A1 Zone 1 Owners Suite
Roof
2,019
0.022 R-38 7.0
None
180
20 New 4.2.1-A9 Zone 2 Living, Kitchen & N
Wall
184
0.069 R-21
70
90 New 4.3.1-A6 Zone 2 Livin ,Kitchen & N
Wall
120
0.069 R-21
160
90 New 4.3.1-A6 Zone 2 Living,Kitchen & N
Wall
246
0.069 R-21
250
90 New 4.3.1-A6 Zone 2 Living,Kitchen & N
Wall
388
0.069 R-21
340
90 New 4.3.1-A6 Zone 2 Livin ,Kitchen & N
Slab
222
0.730 None
0
180 New 4.4.7-A1 Zone 2 Livin ,Kitchen & N
Slab
1 11797
0.730 None
0
180 New 4.4.7-A1 Zone 2 Livin ,Kitchen & N
Roof
1 828
0.022.R-38 7.0
None
180
20 New 4.2.1-A9 lZone 3 Bedroom 2, 3 & 4
Wall
1 3081
0.069 R-21 1
340
90 New 14.3.1-A6 JZone 3 Bedroom 2, 3 & 4
FENESTRATION SURFACE DETAILS
ID
Type Area U -Factor
SHGC
Azm Status
Glazing Type Location/Comments
1
Window
12.5 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
2
Window
12.5 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
3
Window
12.5 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
4
Window
6.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
5
Window
6.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
6
Window
12.5 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
7
Window
11.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
8
Window
12.5 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
9
Window
11.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
10
Window
5.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
11
Window
5.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
12
Window
5.0 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 1 Owners Suite
13
Window
80.0 0.390 NFRC
0.39 NFRC 250 New
Architectural Traditions Window Zone 1 Owners Suite
14
Window
12.0 40.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
15
Window
32.0 0.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
16
Window
12.0 0.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Wndow4 Zone 2 Living, Kitchen & Nook
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen -
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
JBug Screen
0.76
EnergyPro
5. 1 by EnergySoft User Number 6712
RunCode: 2010-10-11 T13:43:59 ID: Page 8 of 35
C �
J
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
0/11/201
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall
302
0.069 R-21
70
90 New 4.3.1-A6 Zone 3 Bedroom 2, 3 & 4
Door
24
0.500 None
70
90 New 4.5.1-A4 Zone 3 Bedroom 2, 3 & 4
Wall
144
0.069,R-21
160
90 New 4.3.1-A6 Zone 3 Bedroom 2, 3 & 4
Wall
20
0.069 R-21
250
90 New 4.3.1-A6 Zone 3 Bedroom 2, 3 & 4
Slab
466
0.730 None
0
180 New 4.4.7-A1 Zone 3 Bedroom 2, 3 & 4
Slab
362
0.730 None
0
180 New 4.4.7-A1 Zone 3 Bedroom 2, 3 & 4
Roof
422
0.022 R-38 7.0
None
180
20 New 4.2.1-A9 Zone 4 Casita
Wall
198
0.069 R-21
340
90 New 4.3.1-A6 Zone 4 Casita
Wall
118
0.069 R-21
70
90 New 4.3.1-A6 Zone 4 Casita
Wall
248
0.069 R-21
160
90 New 14.3.1-A6 Zone 4 Casita
Wall
79
0.069 R-21
250
90 New 14.3.1-A6 Zone 4 Casita
Wall
66
0.069 R-21
295
90 New 4.3.1-A6 Zone 4 Casita
Slab
292
0.730 None
0
180 New 4.4.7-A1 Zone 4 Casita
Slab
130
0.730 None
0
180 New 4.4.7-A1 Zone 4 Casita
FENESTRATION SURFACE DETAILS
ID
Type Area ' U -Factor
SHGC
Azm Status
Glazing Type Location/Comments
17
Window
12.5 0.390 1 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
18
Window
60.3 0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
19
Window
190.0 0.390 NFRC
0.39 NFRC 250 New
Architectural Traditions Window Zone 2 Living, Kitchen & Nook
20
Window
90.0 0.390 NFRC
0.39 NFRC 250 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
21
Window
2.3 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
22
Window
2.3 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 2 Living, Kitchen & Nook
23
Window
2.3 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
24
Window
2.3 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
25
Window
2.3 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
26
Window
2.3 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 2 Living,Kitchen & Nook
27
Window
15.0 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
28
Window
15.0 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
29
Window
8.0 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
30
Window
8.0 0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
31
Window
7.5 0.390 NFRC
0.39 NFRC 3401 New
Architectural Traditions Window one 3 Bedroom Z 3 & 4'
32
Window
12.5 0.390 NFRC
0.39 NFRC 3401 New
Architectural Traditions Windowl Zone 3 Bedroom 2, 3 & 4
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hot Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
113ug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number. 6712
Run Code: 2010-10-11T13:43:59 ID: Page 9 of 35
•
•
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5) CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
0/11/201
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
LI -Factor
SHGC
Azm Status
Glazing Type Location/Comments
33
Window 12.5
0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
34
Window 6.0
0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
35
Window 20.0
0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
36
Window 40.0
0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
37
Window 20.0
0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 3 Bedroom 2, 3 & 4
38
Window 10.0
0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 4 Casita
39
Window 11.0
0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 4 Casita
40
Window 6.0
0.390 NFRC
0.39 NFRC 340 New
Architectural Traditions Window Zone 4 Casita
41
Window 12.5
0.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 4 Casita
42
Window 11.0
0.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 4 Casita
43
Window 12.5
0.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 4 Casita
44
Window 11.0
0.390 NFRC
0.39 NFRC 70 New
Architectural Traditions Window Zone 4 Casita
45
Window 10.0
0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 4 Casita
46
Window 11.0
0.390 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 4 Casita
47
Window 10.0
0.3901 NFRC
0.39 NFRC 160 New
Architectural Traditions Window Zone 4 Casita
48
Window 11.0
0.390 NFRC
0.39 1 NFRC 160 New
Architectural Traditions Windowl Zone 4 Casita
(1) 1.1 -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt REA Dist Len H t Dist Len H t
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
1Bug, Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
39
Bug Screen
0.76
40
Bug Screen
0.76
41
Bug Screen
0.76
42
Bug Screen
0.76
43
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
Bug Screen
0.76
48
IBug Screen
0.76
EnergyPro
5.1 by EnergySoft
User Number. 6712
Run Code: 2010-10-11713:43:59 /D: Pae 10 of 35
•
L]
C ,
J
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
0/11/201
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments
49 Window 10.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 4 Casita
50 Window 11.0 0.390 NFRC 0.39 NFRC 250 New Architectural Traditions Window Zone 4 Casita
51 Window 24.0 0.390 NFRC 0.39 NFRC 295 New Architectural Traditions Window Zone 4 Casita
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H t Wd Len H t LExt REA Dist Len H t Dist Len H t
49 Bug Screen 0.76
50 Bug Screen 0.76
51 Bug Screen 0.76
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-11713.43:59 ID: Pae 11 of 35
•
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Traditions Lot 8
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11011112016
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC 1 Zone 1 Owners Suite
977
10,747
HVAC 2 & 3 Zone 2 Living, Kitchen & Nook 2,019
22,209
HVAC 4 Zone 3 Bedroom Z 3& 4
828
8,280
HVAC 5 Zone 4 Casita
422
4,220
Totals 4,246 0 0 0
HVAC SYSTEMS
System Name Qt . HeatingType
Min. Eff. CoolingType Min. Eff. Thermostat Type Status
HVAC 1
1 Central Furnace
80% AFUE Split Air Conditioner 14.0 SEER Setback
New
HVAC 2 & 3
2 Central Furnace
80% AFUE Split Air Conditioner 14.0 SEER Setback
New
HVAC 4
1 Central Furnace
80% AFUE Split Air Conditioner 14.0 SEER Setback
New
HVAC 5
1 Central Furnace
80% AFUE Split Air Conditioner 14.0 SEER Setback
New
HVAC DISTRIBUTION
System Name
Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
m New
HVAC 2 & 3 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
p New
HVAC 4 Ducted
Ducted Attic, Ceiling Ins, vented 1 4.21
lNew
HVAC 5 Ducted I
Ducted JAttic, Ceiling Ins, vented 4.21
INew
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White EF -100T-
1
Large Gas
All Pipes Ins
150,000
100
0.99
0.00%
0.0
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
7
m
w a
Hot Water Piping Length
ft
o
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
EnemyPro 5. 1 by EnemySoft
User Number. 6712
RunCode: 2010.10-11713:43:59 ID:
Pae 12 of 35
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
raditions Lot 8
Date
11011112010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
e 1 A: Mason or factory -built fireplaces have a closable metal or lass door coveringthe entire opening of the firebox.
(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
El ed with a with a readil accessible, o erable, and ti ht-fittin dam er and or a combustion -air control device.
(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
de of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA.
§1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-11T13:43:59 ID: Page 13 of 35
r
i�
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Traditions Lot 8
11011112010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-10-11713:43:59 ID: Page 14 of 35
4
ANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
ject Name
r
Date
ditionss Lot 8
11011112010
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoff User Number. 6712 Run Code: 2010-10-11713:43:59 ID: Page 15 of 35
r
i�
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
raditions Lot 8
Date
10/11/2010
System Name
HVAC 1
Floor Area
977
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 720
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 71,000
14,445
2,049 332
14,303
Total Output Stuh 71,000
0
Output Btuh/s ft 72.7
1,043
1,016
Cooling System
0
0
Output per System 47,500
0
0 0
0
Total Output Btuh 47,500
0
2,0491
0
Total Output Tons 4.0
1,043
1,016
Total Output Btuh/s ft 48.6
Total Output s ftlron 246.8
16,532
1 16,335
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ACA448/58CVX090 34,185
3,741
71,000
71,000
I Jan 1 AM
Airflow cfm/s ft 1.64
Airflow cfm/Ton 404.2
Outside Air % 0.0%
Total Adjusted System Output 34,185
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
3,741
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
71 OF
71 OF 113 OF 113 OF
i (�] r'
Heating Coil Supply Fan
1,600 cfm 113 OF
i ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
71/58°F
4 Ar .
71/58°F 51/50°F 51/50°F
Cooling Coil Supply Fan 51 / 50 OF
1,600 cfm:............_.._.............. ......._..M
48.2% ROOM
_ 70/58°F
4 3 4 1
EnergyPro 5.1 by EnergySofi
User Number. 6712 RunCode: 2010-10-11 T13:43:59 ID:
Page 16 of 35
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
raditions Lot 8
Date
10/11/2010
System Name
HVAC 2 & 3
Floor Area
2,019
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,416
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
28,670
3,380 504
21,865
Total Output Btuh 142,000
0
2,071
0
Output Btuh/s ft 70.3
1,553
Cooling System
0
Output perSystem 47,500
0
0 0
0
Total Output Btuh 95,000
0
2,071
1 32,8121 3,3801
0
Total Output Tons 7.9
1,553
Total Output Btuh/s ft 47.1
Total Output s ft/Ton 255.0
1 24,971
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
3,200
Carrier 24ACA448/58CVX090 68,941
6,708
142,000
142,000
Jan 1 AM
Airflow cfm/s ft 1.58
Airflow cfm/Ton 404.2
Outside Air % 0.0%
Total Adjusted System Output 68,941
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
6,708
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF /
10
Outside Air
0 cfm
72 OF
-d 914
72 OF 113 OF 113 OF
Heating Coil Supply Fan o
3,200 cfm 113 F
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside AirNO:
0 cfm
71/58°F
71/58°F 50/49°F 50/49°F
Cooling Coil Supply Fan 51 / 50 OF
3.200 cfm _........_.._ _.................
47.6% ROOM
70/58°F
EnergyPro 5.1 by EnergySoR
User Number: 6712 RunCode: 2010.10-11T13.43:59 /D:
Page 17 of 35
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Traditions Lot 8
Date
10/11/2010
System Name
HVAC 4
Floor Area
828
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 610
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
12,395
1,858 279
12,100
Total Output Btuh 71,000
0
Output Btuh/s ft 85.7
895
860
Cooling System
0
0
Output perSystem 47,500
0
0 0
0
Total Output Btuh 47,500
0
895
14,186 1,858
0
Total Output Tons 4.0
860
Total Output Btuh/s ft 57.4
Total Output s ft/Ton 209.2
13,819
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24AGA448/58CVX090
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
34,308 3,529 71,000
34,308 3,529 71,000
Aug 3 PM I Jan 1 AM
Airflow cfm/s ft 1.93
Airflow cfm/Ton 404.2
Outside Air % 0.0%
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air -4 V-
0 cfm
71 OF
71 OF 113 OF 113 OF
M
Heating Coil Supply Fan
1,600 cfm
113 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm •
71/58°F
4 AV 1
71/58°F 50/49°F 50/49°F
Cooling Coil Supply Fan
1,600 cfm.
— — 3 4
51 / 50 OF
_..... ._.._.. ,,
47.8% R
! OOM
70/58°F
1
EnergYPro 5.1 by EnergySoft
User Number: 6712 RunCode: 2010-10-11 T13:43:59
ID: Page 18 of 35
r
L_
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
raditions Lot 8
Date
10/11/2010
System Name
HVAC 5
Floor Area
422
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 611 11,282
Return Vented Lighting 0
Return Air Ducts 815
Return Fan o
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 815
TOTAL SYSTEM LOAD 1 12,912
COIL HTG.
Latent CFM
1,339 154
0 0
1,339
PEAK
Heating System
Sensible
Output perSystem 51,000
9,581
Total Output Btuh 51,000
Output Btuh/s ft 120.9
681
Cooling System
0
Output perSystem 23,500
0
Total Output Btuh 23,500
0
Total Output ons 2.0
681
Total Output Btuh/s ft 55.7
Total Output s ft/Ton 215.5
10,943
Air System
CFM perSystem
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Carrier 24ACA424/58CVX071 16,400
2,611
51,000
Airflow cfm/s ft
1.90
Airflow cfm/Ton
408.5
51,000
Jan 1 AM
Outside Air % 0.0%
Total Adjusted System Output 16,400
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
2,611
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
71 OF
71 OF 131 OF 131 OF
Heating Coil Supply Fan o
800 cfm 130 F
ROOM in
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air -4,-
0 cfm
71/59°F
71/59°F 52/51°F 52/51°F
-------
IF
a
Cooling Coil Supply Fan
800 cfm
51.0%
53 / 51 OF
_.....___............__.._..__..._. ,
� ROOM
70/59°F
EnergyPro 5.1 by EnergySoft
User Number: 6712 RunCode: 2010-10-11713:43:59 /D:
Page 19 of 35
•
•
•
ROOM LOAD SUMMARY
Project Name Date
Traditions Lot 8 10/11/2010
HVAC 2 & 3 1 2,019
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Zone 2 Living, Kitchen & No Zone 2 Living, Kitchen & 1 1,416 28,670 3,380 1,416 28,670 3,380 504 21,865
Total includes ventilation load for zonal
PAGE TOTAL
TOTAL"
1,416
28,670
3,380
504
21,865
1,416
28,670
3,380
504
21,865
•
•
ROOM LOAD SUMMARY
Project Name Date
Traditions Lot 8 10/11/2010
System Name Floor Area
HVAC 4 828
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Zone 3 Bedroom 2, 3 & 4 Zone 3 Bedroom Z 3 & 4 1 1 6101 1Z3951 1,858 610 1Z3951 1,8581 2791 12,100
PAGE TOTAL
TOTAL
610 12,395
1,858
279
12,100
610 12,395
1,858
279
12,100
•
�11
•
ROOM LOAD SUMMARY
Project Name Date
Traditions Lot 8 10/11/2010
System Name Floor Area
HVAC 5 422
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Zone 4 Casita Zone 4 Casita 1 611 11,282 1,339 6111 11,2821 1,339 1541 9,581
PAGE TOTAL
TOTAL'
611
11,282
1,339
154
9,58
611
11,2821
1,3391
154
9,5R]
•
ROOM HEATING PEAK LOADS
Project Name
Traditions Lot 8
Date
10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 1 Owners Suite
Floor Area 977.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X 0.0220
X 0.0690
X 0.3900
X 0.7300
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room
11.00 X 0.289
Ceiling Height ACH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
977.0
46
989
R-21 Wall (W.19.2x6.16)
1,023.5
46
3,249
Architectural Traditions Windows
191.5
46
3,436
Slab -On -Grade
perim = 122.0
46
4,097
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 x 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 977 X
Area
Page Total
/60] X
AT
1 11,769
= 2,533
TOTAL HOURLY HEAT LOSS FOR ROOM 14,303
Energ Pro 5.1 by Energ Soft User Number., 6712 RunCode: 2010-10-11T13.43:59 /D: Page 24 of 35
r�
U
L�
ROOM HEATING PEAK LOADS
Project Name
Traditions Lot 8
Date
10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 2 Living, Kitchen & Nook
Floor Area 2,019.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
0.0220 X
0.0690 X
0.3900 X
0.7300 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
another room
11.00 X 0.289
Height ACH
AT °F
_
c
a
=
o
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
2,019.0
X
X
X
46
2,043
R-21 Wall (W.19.2x6.16)
937.4
46
2,975
Architectural Traditions Windows
422.6
46
7,581
Slab -On -Grade
perim = 120.0
X
46
4,030
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to
1.064 X 2,019 X
Area Ceiling
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
Page Total
/60] X
AT
16,629
= 5,235
TOTAL HOURLY HEAT LOSS FOR ROOM 21,865
Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2010-10-11713.43:59 /D: Page 25 of 35
•
ROOM HEATING PEAK LOADS
Project Name
Traditions Lot 8
Date
10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 3 Bedroom 2, 3 & 4
Floor Area 828.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
. Area
U -Value
X 0.0220
X 0.0690
X 0.3900
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
828.0
46
838
R-21 Wall (W.19.2x6.16)
773.5
46
2,455
Architectural Traditions Windows
164.5
46
2,951
Wood Door
24.0
X
0.5000
46
552
Slab -On -Grade
perim = 94.0
X
X
X
0.7300
46
3,157
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 828 X
Area
to another room
10.00 X 0.318
Ceiling Height ACH
Page Total
/60] X
AT
9,953
= 2,147
TOTAL HOURLY HEAT LOSS FOR ROOM 12,100
Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2010-10-11713:43:59 /D: Page 26 of 35
C
ROOM HEATING PEAK LOADS
Project Name710/11/2010
Traditions Lot 8
ate
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 4 Casita
Floor Area 422.0 ft2
Indoor Dry Bulb Tem erature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
422.0 X
709.0 X
161.0 X
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
Btu/hr
R-38 Roof(R.38.2x14.16)
0.0220
46
c
=
=
c
=
=
427
R-21 Wall (W.19.2x6.16)
0.0690
46
2,250
Architectural Traditions Windows
0.3900
46
2,888
Slab -On -Grade
perim = 87.0
X
X
X
0.7300
46
2,921
X
=
=
X
X
=
=
X
X
=
X
X
X
X
X
=
=
=
=
X
X
=
=
=
X
X
X
X
X
=
=
=
=
X
=
X
=
=
X
X
X
X
=
=
=
X
X
through an interior surface to
X 422 X
Area Ceiling
=
=
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
another room
10.00 X 0.318
Height ACH
Page Total
/60] X 46
AT
8,487
= 1,094
TOTAL HOURLY HEAT LOSS FOR ROOM 9,581
Energ Pro 5.1 by Energ Soft User Number. 6712 Run Code: 2010-10-11713:43:59 /D: Page 27 of 35
J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Traditions Lot 8 1 10/11/2010
Room Name
Zone 1 Owners Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area
977.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temaerature
70 OF I
Outdoor Dally Ranae:
34 OF
Opaque Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16) I
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
977.0
0.0220
56.0
538.5
0.0690
28.2
80.0
0.0690
32.1
275.01
0.0690
29.0
130.0
0.0690
31.2
22.3
6.0
26.3
0.0
22.3
6.0
26.3
0.0
22.3
12.5
26.3
0.0
22.3
11.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
1
2
3
4
5
6
7
8
9
Orientation
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
22.3
12.5
26.3
0.0
22.3
12.5
26.3
0.0
22.3
12.5
26.3
0.0
22.3
6.0
26.3
0.0
22.3
6.0
26.3
0.0
22.3
12.5
26.3
0.0
22.3
11.0
26.3
0.0
22.3
12.5
26.3
0.0
22.3
11.0
26.3
Page Total
Btu/hr
1,203
1,049
177
550
280
3,
Btu/hr
329
329
329
158
158
329
289
329
289
Internal Gain Btu/hr
Occupants 4.0 Occupants X 230 Btuh/occ.
Equipment 1.0 Dwelling Unit X 1,600 Btu =
Infiltration: 1.064 )( 0.94 X 53.46 X 42 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14.4451
Latent Gain Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ. = 800
Infiltration: 4,771 X 0.94 X 53.46 X 0.00523 = 1,249
Air Sensible CFM ELA AW
101
TOTAL HOURL
r:
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Traditions Lot 8
1 10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 1 Owners Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area 977.0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1 0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
10 (S) 0.0 X 22.3 +
5.0
X 26.3
= 132
11 (S) 0.0 X 22.3 +
5.0
X 26.3
= 132
12 (S) 0.0 X 22.3 +
5.0
X 26.3
= 132
13 (tM 0.0 X 22.3 +
80.0
X 43.7
= 3,497
X +
X
=
X +
X
-
X +
X
-
X +
X
=
X +
X
-
Page Total
1 3,892
Internal Gain
Btu/hr
Occupants 4.0 Occupants X 230
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 X 0.94 X 53.46 X 42 =
2,235
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
14,445
Latent Gain
Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ.
=
800
Infiltration: 4,771 X 0.94 X 53.46 X 0.00523 =
1,249
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2,049
EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-10-11T13:43:59 ID:
Page 29 of 35
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Traditions Lot 8
ROOM INFORMATION DESIGN CONDITIONS
Room Name Zone 2 Living, Kitchen & Nook Outdoor Dry Bulb Temperature
Floor Area 2,019.0 ft' Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae:
Opaque Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W.19.2x6.16) I
Orientation
(S)
(S)i
Date
10/11/2010
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
2,019.0
0.0220
56.0
183.5
0.0690
31.2
119.7
0.0690
28.2
246.01
0.0690
32.1
388.2
0.0690
29.0
22.3
12.5
40.7
0.0
22.3
60.3
26.3
0.0
22.3
190.0
43.7
0.0
22.3
90.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
14
15
16
17
18
19
20
21
22
Orientation
(E)
(E)
(E)
(E)
(S)
(149
(►M
(N)
(N)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
22.3
12.0
40.7
0.0
22.3
32.0
40.7
0.0
22.3
12.0
40.7
0.0
22.3
12.5
40.7
0.0
22.3
60.3
26.3
0.0
22.3
190.0
43.7
0.0
22.3
90.0
43.7
0.0
22.3
2.3
34.8
0.0
22.3
2.3
34.8
Page Total
112 OF
78 OF
34 OF
Btu/hr
2,487
395
233
545
4,
Btu/hr
489
1,303
489
509
1,587
8,305
3,934
80
80
16, 775
Internal Gain
Btu/hr
Occupants
4.0
Occupants X230
Btuh/occ. `
Equipment
1.0
Dwelling Unit X
1,600 Btu
Infiltration: 1.064 )( 0.94 X 110.48 X
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,6701
Latent Gain Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ. = 800
Infiltration: 4,771 X 0.94 X 110.48 X 0.00523 = 2,580
Air Sensible CFM ELA AW
101
TOTAL HOURLY LATENT HEAT
I -J
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Traditions Lot 8
10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 2 Living, Kitchen & Nook
Outdoor Dry Bulb Temperature
112 OF
Floor Area 2,019.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
23 (IV) 0.0 X 22.3 +
2.3
X 34.8
= 80
24 (N) 0.0 X 22.3 +
2.3
X 34.8
= 80
25 (N) 0.0 X 22.3 +
2.3
X 34.8
= 80
26 (N) 0.0 X 22.3 +
2.3
X 34.8
= 80
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
Page Total
1 320
Internal Gain
Btu/hr
Occupants 4.0 Occupants X 1 230
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 X 0.94 X 110.48 X 42 =
4,618
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
28,670
Latent Gain
Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ.
=
800
Infiltration: 4,771 X 0.94 X 110.48 X 0.00523 =
2,580
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
3,380
EnemyPro 5.1 by EnemySoft User Number. 6712 RunCode: 2010-10-11713:43:59 /D:
Page 31 of 35
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Traditions Lot 8 --710/11/2010
ROOM INFORMATION DESIGN CONDITIONS
Room Name Zone 3 Bedroom 2, 3 & 4 Outdoor Dry Bulb Temperature 112 OF
Floor Area 828.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: 34 OF
Opaque Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
Wood Door
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W.19.2x6.16)
Orientation
(E)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
c
=
c
=
828.0
0.0220
56.0
307.5
0.0690
29.0
302.0
0.0690
31.2
24.0
0.5000
31.2
144.0
0.0690
28.2
20.0
0.0690
32.1
0.01
22.3
7.5
34.8
0.0
22.3
12.5
J
0.0
22.3
12.5
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fanactratinn
27
28
29
30
31
32
33
34
35
Internal Gain
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(S)
(S)
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
c
0
=
=
=
=
=
0.0
22.3
15.0
34.8
0.0
22.3
15.0
34.8
0.0
22.3
8.0
34.8
0.0
22.3
8.0
34.8
0.01
22.3
7.5
34.8
0.0
22.3
12.5
34.8
0.0
22.3
12.5
34.8
0.0
22.3
6.0
26.3
0.0
22.3
20.0
26.3
4.0 Occupants X 230 Btuh/occ.
1.0 Dwelling Unit X 1,600 Btu
Infiltration: 1.064 X 0.94 X 45.31 X 42 =
Air Sensible CFM ELA AT
Page Total
Btu/hr
1,020
615
651
280
2,
Btu/hr
522
522
279
279
261
435
435
158
526
3,417
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,3951
Latent Gain
4.0 Occupants X 200 Btuh/occ.
Btu/hr
c 800
Infiltration: 4,771 X 0.94 X 45.31 X 0.00523 = 1,058
Air Sensible CFM ELA AW
. TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,858
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Traditions Lot 8
1 10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Zone 3 Bedroom 2, 3 & 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
828.0ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range.
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
36
(S) 0.0 X 22.3 +
40.0 X 26.3
= 1,053
37
(S) 0.0 X 22.3 +
20.0 X 26.3
= 526
X +
X
=
X +
X
—
X +
X
-
X +
X
-
X +
X
=
X +
X
-
X +
X
-
Page Total
1,579
Internal Gain
Btu/hr
Occupants
4.0 Occupants X 230
Btuh/occ. =
E920
Equipment
1.0 Dwelling Unit X 1,600
Btu =
1,600
Infiltration: 1.064
X 0.94 X 45.31 X 42 =
1,894
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
12,395
Latent Gain
Btu/hr
Occupants
4.0 Occupants X 200
Btuh/occ. =
800
Infiltration: 4,771
X 0.94 X 45.31 X 0.00523 =
1,058
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,858
EnemvPro 5.1 by EnemySoft
User Number: 6712 RunCode: 2010-10-11T13:43:59 ID:
Page 33 of 35
I RESIDENTIAL ROOM COOLING LOAD SUMMARY
Traditions Lot 8
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temper.
Opaque Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W..19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (IN. 19.2x6.16)
R-21 Wall (W. 19.216.16)
Orientation
Zone 4 Casita Outdoor Dry Bulb Temperature
422.0 ft2 Outdoor Wet Bulb Temperature
70 OF I Outdoor Dailv Ranae:
(S)
z
Date
10/11/2010
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
422.0
0.0220
56.0
198.0
0.0690
29.0
118.0
0.0690
31.2
248.0
0.0690
28.2
79.0
0.0690
32.1
66.0
0.0690
31.5
0.0
22.3
11.0
40.7
0.0
22.3
12.5
40.7
0.0
22.3
11.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
38
X
X
X
X
X
X
X
X
X
39
+
+
+
+
+
+
+
+
+
40
41
X
X
X
X
X
X
X
X
X
42
=
=
=
=
=
=
=
=
=
43
22.3
44
34.8
45
22.3
46
34.8
Orientation
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
22.3
10.0
34.8
0.0
22.3
11.0
34.8
0.0
22.3
6.0
34.8
0.0
22.3
12.5
40.7
0.0
22.3
11.0
40.7
0.0
22.3
12.5
40.7
0.0
22.3
11.0
40.7
0.0
22.3
10.0
26.3
0.0
22.3
11.0
26.3
Page Total
112 OF
78 OF
34 OF
Btu/hr
520
396
254
483
175
143
Btu/hr
348
383
209
509
448
509
448
263
289
3,406
Internal Gain Btu/hr
Occupants 4.0 Occupants X 230 Btuh/occ. = 920
Equipment 1.0 Dwelling Unit X 1,600 Btu 1,600
Infiltration: 1.064 X 0.94 X 23.09 X 42 =
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11.2821
Latent Gain Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ. = 800
Infiltration: 4,771 X 0.94 X 23.09 X 0.00523 = 539
Air Sensible CFM ELA AW
0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Traditions Lot 8
1 10/11/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Zone 4 Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 422.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area
U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1 0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area
GLF Area GLF
Btu/hr
47 (S)
0.0 X 22.3 +
10.0 X
26.3
= 263
48 (S)
0.0 X 22.3 +
11.0 X
26.3
= 289
49 (W)
0.0 X 22.3 +
10.0 X
43.7
= 437
50 (1/109
0.0 X 22.3 +
11.0 X
43.7
= 481
51 (NVIvq
0.0 X 22.3 +
24.0 X
39.5
= 949
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
2,419
Internal Gain
Btu/hr
Occupants 4.0 Occupants X
230
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1
1,600
Btu
=
1,600
Infiltration: 1.064 X 0.94 X 23.09 X 42 =
965
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
11,282
Latent Gain
Btu/hr
Occupants 4.0 � Occupants X 200
Btuh/occ.
=
800
Infiltration: 4,771 X 0.94 X 23.09 X 0.00523 =
539
Air Sensible CFM EL A
AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,339
EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2010-10-11713:43:59 ID:
Pa - e 35 of 35