BRES2014-1099 Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Custom Residence Lot 5, Traditions La Quinta, CA 92253 Project Designer: Helton, DeFord & Associates 174'11 Irvine Blvd., Suite O Tustin, CA 92780 (909) 957-4550 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77085 Michigan Drive Palm Desert, CA 92211 (760) 200 4780 FB ITY OF LA QUINTA UILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 8Y ob Number: ' Date: 10/30/2014 OCT 312014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC–www.energysoft.com. —EnegyPro 6.3 by- Ene Soft User Number. 6712 /D: fl CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F&OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFI,RF-01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Custom Res 02 This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 02 Calculation Description Title 24 Analysis 03 Project Location Lot 5, Traditions ENERGY USE SUMMARY 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 247 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 4637 15 .R� Number of Zones 6 16 Slab Area (FT2) 4637 17� Number of Stories 1 18 Addition Cond. Floor Area N/A e19 -P Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A �1 Glazing Percentage (%) 23.2% AW COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown3below ENERGY USE SUMMARY 04 05V 06 07 08 Energy Use (kTDV/ft) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating A,, ;)3.31 1.87 1.44 43.5% Space Cooling 97.35 95.45 1.90 2.0% IAQ Ventilation Q� 1.82 1.82 0.00 0.0% Water Heating 5.85 ` >; t x .•�..- .6.89 -1.04 -17.8% Photovoltaic Offset —:001) LA—at—A -- 0.00lot— -- Compliance Energy Total R.� 108.33I 8Llt3i_ 1 06 & S - ' �! Oc .. 2.30 2.1% .,0 Registration Number: �%! CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance APPROVE® FOR CONSTRUCTION DATE BY Registration D Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE O&OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFI,WF-01 Page 2 of 12 I REQUIRED SPECIAL FEATURES I The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Cathedral Ceiling • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: Q' • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: — None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components ni cluded in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24 Pah 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. 4. 4 Reference E nfer�y Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2)• 146 07 143.77 2.30 1.6% includes calculated Appliances and Miscellaneous Energy Use (AMEE �L BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned F o` G—r A Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Custom Res 4837;' 1 18 6 0 2 e®49 Registration Number: 0► CA Building Energy Efficiency Standards` - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFIWF-01 Page 3 of 12 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Suite Conditioned HVAC 11 1095 11 DHW Sys 1 Living/Entry/Office Conditioned HVAC 22 1443 12.5 DHW Sys 1 Kitchen/Dining Conditioned HVAC 33 996 10 DHW Sys 1 Bedroom 2 Conditioned HVAC 33 309 10 DHW Sys 1 Bedroom 3 Conditioned HVAC 33 321 10 DHW Sys 1 Casita Conditioned HVAC 44 4 10 DHW Sys 1 Llw '®p v� `e q�® Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xm1 CFWF-01 Page 4 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) 57d Wall Master Suite R-21 Wall (W.19.2x6.16) 57 - specify - 198 96 90 147d Wall Master Suite R-21 Wall (W.19.2x6.16) 147 - specify - 28 0 90 157d Wall Master Suite R-21 Wall (W.19.2x6.16) 157 Right 95 0 90 237d Wall Master Suite R-21 Wall (W.19.2x6.16) 237 - specify - 75 0 90 247d Wall Master Suite R-21 Wall (W.19.2x6.16) 247 Front 130 0 90 327d Wall Master Suite R-21 Wall (W.19.2x6.16) b,327 - specify - 494 66.5 90 337d Wall Master Suite R-21 Wall (W.19.2x6.16) �� 337 Left 165 0 90 R-38 Roof 2 Master Suite R-38 Roof(R.38.2x14.16) ►. 1095 67d Wall Living/Entry/Office R-21 Wall (W.19.2x6.16)�` 67 Back 480 278 90 157d Wall 2 Living/Entry/Office R-21 Wall (W.19.2x6.6R 157 Right 168 25 90 247d Wall 2 Living/Entry/Office R-21 Wall (W.19.2x616) 247 Front 270 148 90 R-38 Roof 3 Living/Entry/Office R-38 Roof(R.382�x,14.16) 1431 67d Wall 2 Kitchen/Dining R-21 Wall (W.1:9�2x6.16) 67 Back 210 133 90 157d Wall 3 Kitchen/Dining R-21 Wall,(1/ .19.2x6.16) 157 Right 720 95 90 247d Wall 3 Kitchen/Dining R-21 Wall (W.19.2x6.16) 247 Front 175 0 90 337d Wall 2 Kitchen/Dining R-3,1�VVall (W.19.2x6.16) 337 Left 65 47 90 R-38 Roof 4 Kitchen/Dining R WRoof(R.38.2x14.16) 996 247d Wall 4 Bedroom 2 �,•fra--21 Wall (W.19.2x6.16) 247 Front 20 0 90 337d Wall 3 Bedroom 2 r R-21 Wall (W.19.2x6.16) r 337 Left 168 36 90 R-38 Roof 5 Bedroom 2 R-38 Roof(R.38.2x14.16) 309 67d Wall 3 Bedroom 3 ®` R-21 Wall (W.19.2x6.16) 67 Back 20 0 90 157d Wall 4 Bedroom 3 A_ R-21 Wall (W.19.2x6.16) 157 Right 90 0 90 247d Wall 5 Bedroom 3 '1 R-21 Wall (W.19.2x6.16) 247 Front 170 0 90 337d Wall 4 Bedroom&A _ R-21 Wall (W.19.2x6.16) 337 Left 200 42 90 R-38 Roof 6 Bedroom 3 R-38 Roof(R.38.2x14.16) 321 67d Wall 4 C�a ha R-21 Wall (W.19.2x6.16) 67 Back 185 80 90 157d Wall 5 4:9asita R-21 Wall (W.19.2x6.16) 157 Right 320 0 90 247d Wall 6 e► Casita R-21 Wall (W.19.2x6.16) 247 Front 185 12.5 90 337d Wall 5 Casita R-21 Wall (W.19.2x6.16) 337 Left 320 6 90 R-38 Roof 7 169V Casita R-38 Roof(R.38.2x14.16) 473 �,V Registration Number: �� Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:16 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I&OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml C CFORF-01 Page 5 of 12 OPAQUE SURFACES— Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio n Area (W) . Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectan ce Roof Emmittanc a Framin g Factor R-38 Roof Living/Entry/Office R-38 Roof(R.38.2x14.16)1 specify- 1 12.1 4 0 0 0 0.1 0.85 0.1 ATTIC 01 02 03 04� 05 06 07 Name Construction Roof Rise Roof Refiectance Roof Emittance Radiant Barrier Cool Roof .rWw Attic Attic Roof Cons 0 �A0.1 0.85 No No Registration Number: A� Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards�- 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:16 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF&F-01 Page 6 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height Width(ft) (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading 1C Window 57d Wall (- specify -57) -- - 1 24.0 0.32 0.23 Insect Screen (default) 1 C 2 Window 57d Wall (- specify -57) -- -- 1 48.0 0.32 0.23 Insect Screen (default) 1C 3 Window 57d Wall (- specify --57) -- - 1 24.0 0.32 0.23 Insect Screen (default) 101 Window 327d Wall (- specify -327) -- -- 1 12.5 0.32 0.23 Insect Screen (default) 102 Window 327d Wall (- specify -327) < - 1 48.0 0.32 0.23 Insect Screen (default) 103 Window 327d Wall (- specify --327) -- -- 1 6.0 0.32 0.23 Insect Screen (default) 1 D Window 67d Wall (Back -67) -,`� -- 1 48.0 0.32 0.23 Insect Screen (default) 1 E Window 67d Wall (Back -67) - 1 230.0 0.32 0.23 Insect Screen (default) 104 Window 157d Wall 2 (Right -157) ��r- - 1 25.0 0.32 0.23 Insect Screen (default) 1A Window 247d Wall 2 (Front -247) �� - - 1 140.0 0.32 0.23 Insect Screen (default) 100 Window 247d Wall 2 (Front -247) `'� -- -- 1 8.0 0.32 0.23 Insect Screen (default) Skylight Skylight R-38 Roof (- specify -157) A~ 1 4.0 0.51 0.28 Skylight 2 Skylight R-38 Roof (- specify -157) V 1 4.0 0.51 0.28 Skylight 3 Skylight R-38 Roof (- specify -157) �10 1 1 4.0 0.51 0.28 1G Window 67d Wall 2 (Back -67) 13.3 10.0 1 133.0 0.32 0.23 Insect Screen (default) 105 Window 157d Wall 3 (Right-15,tjj -- -- 1 25.0 0.32 0.23 Insect Screen (default) 106 Window 157d Wall 3 (Right --;1,57) -- - 1 25.0 0.32 0.23 Insect Screen (default) 107 Window 157d Wall 3 (Rig'h-t=157) - - 1 45.0 0.32 0.23 Insect Screen (default) 1F Window 337d Wall 2 (Left -337) -- - 1 47.0 0.32 0.23 Insect Screen (default) 111 Window 337d WaIPl (Left -337) - -- 1 36.0 0.32 0.23 Insect Screen (default) 109 Window 337d= -Wall 4 (Left -337) -- -- 1 36.0 0.32 0.23 Insect Screen (default) 110 Window 337d Wall 4 (Left -337) - - 1 6.0 0.32 0.23 Insect Screen (default) 1N Window _6A Wall 4 (Back -67) -- - 1 20.0 0.32 0.23 Insect Screen (default) 1 N 2 Window tF67d Wall 4 (Back -67) - - 1 40.0 1 0.32 0.23 Insect Screen (default) 1 N 3 Window 1�01 67d Wall 4 (Back -67) -- -- 1 20.0 0.32 0.23 Insect Screen (default) 112 Window �` w 247d Wall 6 (Front -247) -- -- 1 12.5 0.32 0.23 Insect Screen (default) 113 Window `1v 337d Wall 5 (Left -337) - -- 1 6.0 0.32 0.23 Insect Screen (default) Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF&F-01 Page 7of12 DOORS 01 02 03 04 Name Side of Building Area (ft) U -factor Door 247d Wall 3 24.0 0.50 OVERHANGS AND FINS 01 02 03 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Construction Type Overhang Total Cavity R -value Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent � Flap HL DepAt�h Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 1G 14 0.1 14 14 0 SSC( 0 0 0 1 0 0 0 0 K* -O SURFACE CONSTRUCTIONS ♦�� 01 02 03 �04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 2x43Top Chord of Cavity/ Frame: no insul. /2x4 Top Chrd Roof Truss @ 24 in. Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) ♦ C jt Inside Finish: Gypsum Board e Cavity/Frame: R-9.1 /2x4 R-38 Roof(R.38.2xl4.16) Ceilings (below attic) Wood Framed Ceiling] 2x4 @ 16 in. O.C. R 38 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board • Cavity/ Frame: R-21 /2x6 R-21 Wall (W.19.2x6.16) Exterior Walls Wood Frame all 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof(R.38.2xl4.16)1 Cathedral Ceilings Wfood Framed Ceiling I 2x4 @ 16 in. O.C. R 38 Roofing: Light Roof (Asphalt Shingle) 0 'ey Registration Number: t� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIF.E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE FOOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFF -01 Page 8of12 SLAB FLOORS V 01 02 * V 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Covered Slab Master Suite 728 110 None 1 No Hard Surface Slab Master Suite 367 23 None 0 No Covered Slab 2 Living/Entry/Office 174 41 None 0.8 No Hard Surface Slab 2 Living/Entry/Office 1269 131 None 0.8 No Covered Slab 3 Kitchen/Dining 420 65 None 0.8 No Hard Surface Slab 3 Kitchen/Dining 576 '�32 None 0.8 No Covered Slab 4 Bedroom 2 260 ��/ 12 None 1 No Hard Surface Slab 4 Bedroom 2 49 7 None 0 No Covered Slab 5 Bedroom 3 193 w 60 None 1 No Hard Surface Slab 5 Bedroom 3 128 41 None 0 No Covered Slab 6 Casita 345 �� v 60 None 1 No Hard Surface Slab 6 Casita 12816- 41 None 0 No FWA BUILDING ENVELOPE - HERS VERIFICATION V 01 02 * V 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required NotAequired Not Required — A1' WATER HEATING SYSTEMS A; �" 02 ob►v 03 04 01 02 03 04 05 06 Name System Type �� Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW �Pipe Insulation, All Lines DHW Heater 1 1 .0% DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% w WATER HEATERS 0 01 02 ob►v 03 04 05 06 07 08 Tank Exterior p��V .4 Tank Volume Energy Factor or Insulation Standby Loss Name Heater Element Type Tank Type (gal) Efficiency Input Rating R -value (Fraction) DHW Heater 1 NattU al Gas Small Storage 50 0.62 40000-Btu/hr 0 0 DHW Heater 1 j (Natural Gas Small Storage 50 0.62 40000-Btu/hr 0 0 .,A Registration Number: t� CA Building Energy Efficiency Standa'r'ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 1001 Project Name: Custom Res I Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFORF-01 Page 9 of 12 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A DHW Sys 1 - 1/2 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System �� Cooling System Distribution Floor Area Name System Type Name Ducted ^� Name Ducted System Fan System Served HVAC 11 Heat Pump Heat Pump System 1 Yes# Heat Pump System 1 Yes Air DistributionSystem 1 Heat Pump System 1 1095 HVAC 22 Heat Pump Heat Pump System 2 Yes Heat Pump System 2 Yes Air Distribution System 2 Heat Pump System 1 -hers -cool 1443 HVAC 33 Heat Pump Heat Pump System 3 (� Yes Heat Pump System 3 Yes Air Distribution System 3 1626 HVAC 44 Heat Pump Heat Pump System Yes Heat Pump System 4 I Yes I Air Distribution System 4 No 473 1 -hers -cool Heat Pump System 3 ,A I 58000 36000 16 12.5 No HVAC - HEATING SYSTEMS: Heat Pumps 01 02 04 05 06 07 08 09 10 ^g03 <� Heating Cooling Zonally Multispeed HERS Name Type 44 � HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pump System 1 SplitHeatPump Av 9 HSPF 47000 29200 16 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System Heat Pump System 2 SplitHeatPump *!► 9 HSPF 58000 36000 16 12.5 No No 1 -hers -cool Heat Pump System 3 SplitHeatPumpV 9 HSPF 58000 36000 16 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 4 -�� SplitH�A ump 9 HSPF 25000 15300 17 13 No No Heat Pump System 1 -hers -cool , Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-3014:43:16 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I0OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF06F-01 Page 10 of 12 HVAC HEAT PUMP COOLING - HERS VERIFICATION 01 02 03 04�"� 01 02 03 04 05 Name Verified Airflow Verified EER Verified SEER Verified Refrigerant Charge HVAC 11 SCSysRpt 1 350 Not Required Required Verified HVAC 22 SCSysRpt 1 350 Not Required Required. Verified HVAC 33 SCSysRpt 1 350 Not Required Required Verified HVAC 44 SCSysRpt 1 350 Not Required Required Verified HVAC - DISTRIBUTION SYSTEMS 01 02 03 04�"� 05 06 07 08 �- Verified Duct Design Low -leakage jW Supply Duct Verification �Xct Leakage Target (%) Verified Duct Location Name Type Duct Leakage Insulation R -value,. Location Return Duct Bypass Duct HERS Verification — 1 -hers -dist w. Air Distribution System 1 Ducts located entirely in Sealed and tested ♦ 8 Conditioned Zone Conditioned Zone None Air Distribution conditioned space Air Distribution SystemW System 1 -hers -dist Air Distribution System 2 Ducts located entirely in Sealed and tested8 a Conditioned Zone Conditioned Zone None Air Distribution conditioned space r, Air Distribution System Required o%9 6.0 System 2 -hers -dist Air Distribution System 3 Ducts located entirely in Sealed and tested ® 8 Conditioned Zone Conditioned Zone None Air Distribution conditioned space System 3 -hers -dist Air Distribution System 4 Ducts located in attic Sealed and tested v y 8 Attic Attic None Air Distribution System 4-0ers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 Duct Leakage �- Verified Duct Design Low -leakage Name Verification �Xct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System Required 6.0 Required Not Required Not Required — 1 -hers -dist w. Air Distribution System Required 0 6.0 Required Not Required Not Required — 2 -hers -dist _ Air Distribution SystemW Required � y 6.0 Required Not Required Not Required — 3 -hers -dist Air Distribution System Required o%9 6.0 Not Required Not Required Not Required — 4 -hers -dist sr .`0 Registration Number: ,p! CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF*F-01 Page 11 of 12 HVAC - FAN. SYSTEMS 01 02 01 01 02 03 • 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC FAN.SYSTEMS - HERS VERIFICATION 01 02 01 02A`� 03 Name VerifiedFanWatt~Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Reguiiced 0.58 HVAC Fan 2-hers-fanRequired Name 0.58 HVAC Fan 3-hers-fanRequired IAQ Fan Type 0.58 HVAC Fan 4 -hers -fan *4� Required 0.58 �0.25 » 0 A~ IAQ (Indoor Air Quality) FANS �v 01 02 03 04 05 06' IAQ Recovery Name . IAQ CFM ,OIAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification DwellingUnit 188.87 �0.25 Default 0 Required Registration Number: q�► CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-10-30 14:43:16 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF*F-01 Page 12 of. 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: / Tim Scott Company: Signature Date: Scott Design and Title 24, Inc, 10/30/2014 Address:- CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State ip: Phone: Palm Desert, CA 92211 %11 (77-60) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT�f I certify the following under penalty of perjury, under the laws of the State of California: ��� 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for�thTM�e building design identified on this Certificate of Compliance. 2.. 1 certify that the energy features and performance specifications identified on this Certificate o�f'Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or.system design features identified on this Certificate of Comp it ance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency f approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Jim Deford . Gj Company: v Date Signed: Helton, DeFord & Associates Address: �� License: 17411 Irvine Blvd., Suite O `i City/State/Zip: Phone: Tustin, CA 92780 �4 (909) 957-4550 c ®* Ap Registration Number: ,,t►�� Registration Date/Time: HERS Provider: - CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:16 4 4 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Custom Residence 11013012014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111(a). 110.7: Exterior doors and windows are weather-stripped; all 4oints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. §150.0(f): Air retarding wrap is tested, labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is greater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. .Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation havinq an installed thermal resistance of R-12 or greater. §150.00)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoR User Number: 6712 /D: Page 15 of 37 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R Project Name Date Custom Residence 10/30/2014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A qas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lams rated 13 Watts or greater shall be electronic and shall have an output frequency <= 20 kHz. §150.0(k)1E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 16 of 37 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Custom Residence 10/30/2014 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with ihe applicable requirements in Sections 110.9, 130.0, 130.2, 130.4 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 4130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and a ress. EnergyPro 6.3 by EnergySoR User Number: 6712 /D: Page 17 of 37 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ustom Residence Date 10/30/2014 System Name HVAC 1 Floor Area 1,095 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 621 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 47,000 12,473 1,800 773 14,032 Total Output Btuh 47,000 0 Output Btuh/s ft 42.9 181 159 Cooling System 0 0 Output per System 47,000 0 0 0 0 Total Output Btuh 47,000 0 1,800 0 Total Output Tons 3.9 181 159 Total Output Btuh/s ft 42.9 Total Output s ft/Ton 279.6 12,834 14,351 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 25HCB648/FV4CNB005 32,511 5,031 29,355 Airflow cfm/s ft 1.46 Airflow cfm/Ton 408.5 Outside Air % 0.0% Total Adjusted System Output 32,511 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,031 Aug 3 PM 29,355 Outside Air cfm/s ft 0.00 Note: values above giyen at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF fns Heating Coil Supply Fan 89 OF 1,600 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/58°F 70/58°F 51/50°F 51/50°F c Cooling Coil Supply Fan 51 / 50 OF 1,600 cfm 49.0% ROOM 70/58°F Energ Pro 6.3 by Energ Soft User Number: 6712 Run Code: 2014-10-30T14:43:43 /D: Page 18 of 37 4 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ustom Residence System Name HVAC 2 Date 10/30/2014 Floor Area 1,443 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,188 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 58,000 20,960 2,372 1,081 19,341 Total Output Btuh 58,000 0 Output Btuh/s ft 40.2 303 220 Cooling System 0 0 Output perSystem 56,500 0 0 0 0 Total Output Btuh 56,500 0 2,372 0 Total Output Tons 4.7 303 220 Total Output Btuh/s ft 39.2 Total Output s ft/Ton 306.5 1 21,567 19,780 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HCB660/FV4CNB006 35,883 10,123 36,225 Airflow cfm/s ft 1.39 Airflow cfmfTon 424.8 Outside Air % 0.0% Total Adjusted System Output 35,883 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,123 Aug 3 PM 36,225 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF ^^ 89 OF fns Heating Coil Supply Fan o 2,000 cfm 89 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm AL F L 70/60°F 53/52°F 53/52°F Elm Cooling Coil Supply Fan 53 / 53 OF 2,000 cfm 53.8% ROOM 70 / 59 OF 6.3 by Energ Soft User Number: 6712 RunCode: 2014-10-30T14:43:43 /D: Page 19 of 37 C 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence Date 10/30/2014 System Name HVAC 3 Floor Area 1,626 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,154 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 58,000 20,236 2,673 1,317 23,506 Total Output Btuh 58,000 0 Output Btuh/s ft 35.7 293 267 Cooling System 0 0 Output perSystem 56,500 0 0 0 0 Total Output Btuh . 56,500 0 293 1 20,821 1 2,673 0 Total Output ons 4.7 267 Total Output Btuh/s ft 34.7 Total Output s ft/Ton 345.3 24,040 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HCB660/FV4CNB006 35,657 10,428 36,225 Airflow cfm/s ft 1.23 Airflow cfm/Ton 424.8 Outside Air % 0-00% Total Adjusted System Output 35,657 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,428 Aug 3 PM 36,225 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions F Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF f Cil r� Heating Coil Supply Fan 89 OF 2,000 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F — - — - Outside Air 0 cfm 70/60°F 70/60°F 53/53°F 53/53°F � 1],-- � Cooling Coil Supply Fan 54 / 53 OF 2,000 cfm - -- 54.2 % ROOM 70/59°F Energ Pro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-10-30714:43:43 ID: Page 20 of 37 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence Date 10/30/2014 System Name HVAC4 Floor Area 473 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 462 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 25,000 7,134 778 272 9,432 Total Output Btuh 25,000 0 Output Btuh/s ft 52.9 412 361 Cooling System 0 0 —Output per S stem 24,000 0 0 0 0 Total Output Btuh 24,000 0 778 0 Total Output Tons 2.0 412 361 Total Output Btuh/s ft 50.7 Total Output s ft/Ton 236.5 7,958 10,153 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 25HCB624/F4BNF003 14,727 5,117 15,614 Airflow cfm/s ft 1.69 Airflow cfm/Ton 400.0 15,614 Outside Air % 0.0% Total Adjusted System Output 14,727 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,117 Aug 3 PM Outside Air cfm/s 0.00 ft Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 105 OF ^^ 105 OF fQ� � Heating Coil Supply Fan 105 OF 800 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/60 OF 70/61 OF 55/54°F 55/54°F O Cooling Coil Supply Fan 55 / 54 OF 800 cfm -- - 57.2 % ROOM 70 / 60 OF Energ Pro 6.3 by Energ Soft User Number., 6712 Run Code: 2014-10-30T14:43:43 /D: Page 21 of 37 • • ROOM LOAD SUMMARY Project Name Date Custom Residence 10/30/2014 System Name Floor Area HVAC 1 1,095 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible Master Suite Master Suite 1 1 621 12,4731 1,800 6211 12,4731 1,800 7731 14,032 PAGE TOTAL TOTAL` 621 12,473 1,800 773 14,032 6211 12,473 1,800 773 14,032 ' Total includes ventilation load for zonal systems. I EnergyPro 6.3 by Ener_gySoR User Number: 6712 Runcode: 2014-10-30T14:43:43 ID: Page 22 of 37 • 0 0 ROOM LOAD SUMMARY 20,236 2,673 1,317 23,506 1,154 20,236 2,673 Project Name Custom Residence 23,506 Date 10/30/2014 System Name HVAC 3 Floor Area 1,626 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Kitchen/Dining Kitchen/Dining 1 769 13,490 1,637 769 13,490 1,637 795 14,195 Bedroom 2 Bedroom 2 1 169 2,968 508 169 2,968 508 155 2,759 Bedroom 3 Bedroom 3 1 215 3,778 528 215 3,778 5281 367 6, 552 Total includes ventilation load RunCode: PAGE TOTAL TOTAL• 1,154 20,236 2,673 1,317 23,506 1,154 20,236 2,673 1,317 23,506 CJ ROOM HEATING PEAK LOADS Project Name Custom Residence Date 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,095.0 ft2 Indoor. Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F _ _ c = c = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 1,095.0 0.0260 46 1,310 R-21 Wall (W 19.2x6.16) 1,022.5 0.0690 46 3,245 Double Non -Metal Tinted 162.5 0.3200 46 2,392 Slab -On -Grade perim = 133.0 0.7300 46 4,466 'R-0 Wall 220.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,095 X Area another room 11.00 X 0.267 Height ACH Page Total /60] X AT 11,413 = 2,619 TOTALHOURLY HEAT LOSS FOR ROOM 14,032 EnergyPro 6.3 by EnergySoR User Number: 6712 RunCode: 2014-10-30T14:43:43 /D: Page 26 of 37 • • C ROOM HEATING PEAK LOADS ' Project Name Custom Residence Date 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Entry/Office Floor Area 1,443.0ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F 46 c Btu/hr R-38 Roof(R.38.2x14.16) 1,431.0 X X X 0.0260 1,711 Double Metal Tinted Skylight 12.0 0.5100 46 c 282 R-21 Wall (W. 19.2x6.16) 467.0 0.0690 46 c = c = 1,482 Double Non -Metal Tinted 451.0 X 0.3200 46 6,639 Slab -On -Grade perim = 172.0 X 0.7300 46 5,776 •R-0 Wall 220.0 X X X X 0.3560 0 0 = = = = = X X X = = X X X = = = X X X X = = = = X X = _ = = = X X X X X X = = X = = X X = = X to another room 12.50 X 0.235 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,443 X Area Page Total /60] X 46 AT 15,890 _ 3,451 TOTAL HOURLY HEAT LOSS FOR ROOM 19,341 EnergyPro 6.3 by EnergySoft User Number 6712 RunCode: 2014-10-30T14:43:43 /D: Page 27 of 37 • • EA ROOM HEATING PEAK LOADS Project Name Custom Residence Date 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen/Dining Floor Area 996.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value 0.0260 X 0.0690 X 0.3200 X 0.5000 X 0.7300 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X X another room 10.00 X 0.293 Height ACH AT 'F Btu/hr R-38 Roof(R.38.2x14.16) 996.0 46 = = 1,191 R-21 Wall (W.19.2x6.16) 871.0 46 2,765 Double Non -Metal Tinted 275.0 46 = 4,048 Wood Door 24.0 46 = 552 Slab -On -Grade perim = 97.0 46 = 3,257 'R-13 Wall 250.0 0 = 0 = = = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 996 X Area Page Total /60] X 46 AT 11,813 = 2,382 TOTAL HOURLY HEAT LOSS FOR ROOM 14,195 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-10-30T14:43:43 ID: Page 28 of 37 CJ C • ROOM HEATING PEAK LOADS Project Name Custom Residence Date 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Floor Area 309.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr R-38 Roof(R.38.2x14.16) 309.0 0.0260 46 = = 370 R-21 Wall (W. 19.2x6.16) 152.0 0.0690 46 482 Double Non -Metal Tinted 36.0 0.3200 46 = 530 Slab -On -Grade perim = 19.0 0.7300 46 = 638 'R-13 Wall 120.0 0.1020 0 = = = 0 = = c = = = = = = = = = = = = = = = = = = = = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 309 X Area another room 10.00 X 0.293 Height ACH Page Total /.60 ] X 46 AT 2,020 = 739 TOTAL HOURLY HEAT LOSS FOR ROOM 2, 759 EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 2014-10-30T14:43:43 /D: Page 29 of 37 r� U r� L' ROOM HEATING PEAK LOADS Project Name Custom Residence. Date 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 Floor Area 321.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT'F _ = c = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 321.0 0.0260 46 384 R-21 Wall (W.19.2x6.16) 438.0 0.0690 46 1,390 Double Non -Metal Tinted 42.0 0.3200 46 618 Slab -On -Grade perim = 101.0 0.7300 46 3,392 'R-13 Wall 120.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 321 X Area another room 10.00 X 0.293 Height ACH Page Total /60] X AT 5,784 = 768 TOTAL HOURLY HEAT LOSS FOR ROOM 6,552 EnergyPro 6.3 by.EnergySoft User Number: 6712 RunCode: 2014-10-30T14:43:43 ID: Page 30 of 37 • • ROOM HEATING PEAK LOADS Project Name Custom Residence Date 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 473.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 473.0 0.0260 46 566 R-21 Wall (W. 19.2x6.16) 911.5 0.0690 46 2,893 Double Non -Metal Tinted 98.5 0.3200 46 1,450 Slab -On -Grade perim = 101.0 0.7300 46 3,392 'R-13 Wall 120.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 473 X Area another room 10.00 X 0.293 Height ACH Page Total /60] X AT 8,300 = 1,131 TOTAL HOURLY HEAT LOSS FOR ROOM 9,432 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-10-30714:43:43 /D: Page 31 of 37 • 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY -J.J.O t IY01IIQ Date Custom Residence 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,095.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Tempera ure 70 OF Outdoor Dailv Ranae: 34 OF Ooaoue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) 'R-0 Wall Orientation (tM (NE) (SE) (SE) (SIA) (SK9 (NM (NW) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,095.01 0.0260 56.0 102.0 0.0690 30.1 28.0 0.0690 29.7 95.0 0.0690 28.6 75.0 0.0690 31.5 130.0 0.0690 32.0 427.5 0.0690 29.5 165.0 0.0690 29.0 220.0 0.356011 0.0 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) n 1C 1C 1C 101 102 103 Orientation (NE) (NE) (NE) (NW) (NW) (NW) Page Total Btu/hr 1,594 212 57 187 163 287 I 3,7011 Shaded Area GLF X 14.9 X 14.9 X 14.9 X 14.9 X 14.9 X 14.9 X X X 1 + + + + + + + + +1 Unshaded Area X X X X X X X X X GLF 0.0 24.0 24.0 = 24.0 = 0.0 48.0 0.0 24.0 24.0 = 22.3 = 0.0 12.5 0.0 48.0 22.3 = 0.0 6.0 22.3 = = = = Page Total Btu/hr 576 1,152 576 279 1,072 134 3, Internal Gain Btu/hr Occupants 3.3 Occupants X 245 Btuh/occ. = 805 Equipment 1,095 Floor Area X 0.50 W/gq ft = 1,869 Infiltration: 1.064 AiX 0.94 X 55.27 X 42 = 2,310 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,473 Latent Gain Btu/hr Occupants 3 3 Occupants X 155 Btuh/occ. = 509 Infiltration: 4,771 X 0.94 X 55.27 X 0.00523 = 1,291 Air Sensible CFM EIA AW FOR ROOM 509 tnerg)(Pro 6.3 by EneroySoft User Number: 6712 Run Code: 2014-10-30T14:43:43 /D• Page 32 of 37 r 1 LJ • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Entry/Office Outdoor Dry Bulb Temperature 112 OF Floor Area 1,443.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 1,431.0 X 0.0260 X 56.0 = 2,084 R-21 Wall (1N.19.2x6.16) (NE) 202.0 X 0.0690 X 31.0 = 431 R-21 Wall (W.19.2x6.16) (SE) 143.0 X 0.0690 X 28.6 = 282 R-21 Wall (W.19.2x6.16) (SM 122.0 X 0.0690 X 32.0 = 269 'R-0 Wall • 220.0 X 0.3560 X 0.0 = 0 X X X X = X X = X X = Page Total 3,066 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr Skylight (W) 0.0 X 20.9 + 4.0 X 58.8 = 235 Skylight (W) 0.0 X 20.9 + 4.0 X 58.8 = 235 Skylight (W) 0.0 X 20.9 + 4.0 X 58.8 = 235 1D (NE) 0.0 X 14.9 + 48.0 X 25.4 = 1,219 1E (NE) 0.0 X 14.9 + 230.0 X 25.4 = 5,640 104 (SE) 0.0 X 14.9 + 25.0 X 17.7 = 442 1A (SM 0.0 X 14.9 + 140.0 X 21.1 = 2,952 100 (SM 0.0 X 14.9 + 8.0 X 21.1 = 169 X + X = Page Total 11,32 Internal Gain Btulhr Occupants 4.3 Occupants X 245 Btuh/occ. = 1,061 Equipment 1,443 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.94 X 72.84 X 42 = 3,045 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,960 Latent Gain Btulhr Occupants 4.3 Occupants X 155 Btuh/occ. = 671 Infiltration: 4.771 X 0.94 X 72.84 X 0.00523 = 1,701 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 671 EnemyPro 6.3 by EneMySoft User Number: 6712 RunCode: 2014-10-30T14:43:43 ID: Page 33 of 37 r -1 L. RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen/Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 996.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I. Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (tq 996.0 X 0.0260 X 56.0 = 1,450 R-21 Wall (W.19.2x6.16) (NE) 77.0 X 0.0690 X 31.0 = 164 R-21 Wall (1N.19.2x6.16) (SE) 625.0 X 0.0690 X 28.6 = 1,231 R-21 Wall (W.19.2x6.16) (SW) 151.0 X 0.0690 X 32.0 = 333 Wood Door (SIM 24.0 X 0.5000 X 32.0 = 384 R-21 Wall (W.19.2x6.16) (NM 18.0 X 0.0690 X 29.0 = 36 'R-13 Wall 250.0 X 0.1020 X 0.0 = 0 X X = X X = Page Total 3,599 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1G (NE) 71.5 X 14.9 + 61.5 X 25.4 = 2,629 105 (SE) 0.0 X 14.9 + 25.0 X 17.7 = 442 106 (SE) 0.0 X 14.9 + 25.0 X 17.7 = 442 107 (SE) 0.0 X 14.9 + 45.0 X 17.7 = 795 1F (NW) 0.0 X 14.9 + 47.0 X 22.3 - 1,050 X + X = X + X = X + X = X +1 X = Page Total 5,35 Internal Gain Btu/hr Occupants 3 0 Occupants X 245 Btuh/occ. = 732 Equipment 996 Floor Area X 0.50 w/sgft = 1,700 Infiltration: 1.064 X 0.94 X 50.27 X 42 = 2,101 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,490 Latent Gain Btu/hr Occupants 3 0 Occupants X 155 Btuh/occ. = 463 Infiltration: 4,771 X 0.94 X 50.27 X 0.00523 = 1,174 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 463 Ene Pro 6.3 by EerqyS,ft User Number: 6712 Run Code: 2014-10-30T14:43:43 /D: Page 34 of 37 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name - Date Custom Residence 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 309.0 fl2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2xl4.16) (lM 309.0 X 0.0260 X 56.0 = 450 R-21 Wall (W.19.2x6.16) (SM 20.0 X 0.0690 X 32.0 = 44 R-21 Wall (W.19.2x6.16) (NtM -132.0 X 0.0690 X 29.0 = 264 'R-13 Wall 120.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = X X = Page Total 758 Items shown with an asterisk ('), denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 111 (NM 0.0 X 14.9 + 36.0 X 22.3 = 804 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 804 Internal Gain Btu/hr Occupants 0.9 Occupants X 245 Btuh/occ. — 227 Equipment 309 Floor Area X 0.50 W/g4 ft = 527 Infiltration: 1.064 X 0.94 X 15.6G X 42 = 652 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 2,968 Latent Gain Btu/hr Occupants 0 9 Occupants X 155 Btuh/occ. = 144 Infiltration: 4,771 X 0.94 X 15.60 X 0.00523 = 364 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 144 EneMyPro 6.3 by EneMySoft User Number: 6712 RunCode: 2014-10-30T14:43:43 /D: Page 35 of 37 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 321.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) - 321.0 X 0.0260 X 56.0 = 467 R-21 Wall (W.19.2x6.16) (NE) 20.0 X 0.0690 X 31.0 = 43 R-21 Wall (W.19.2x6.16) (SE) 90.0 X 0.0690 X 28.6 = 177 R-21 Wall (W.19.2x6.16) (SIM 170.0 X 0.0690 X 32.0 = 375 R-21 Wall (W.19.2x6.16) (NW) 158.0 X 0.0690 X 29.0 = 316 "R-13 Wall 120.0 X 0.1020 X 0.0 = 0 X X = X X = X X = Page Total 1.379 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 109 (NW) 0.0 X 14.9 + 36.0 X 22.3 = 804 110 (NM 0.0 x 14.9 + 6.0 X 22.3 = 134 X + x = X + x = X + X = x + x = X + x = X + x _ X + X = Page Total 938 Internal Gain Btu/hr- tu/hrOccu Occupants ants 10 Occupants X 245 Btuh/occ. = 236 Equipment 321 Floor Area X 0.50 w/sgft = 548 Infiltration: 1.064 X 0.94 X 16.20 X 42 = 677 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,778 Latent Gain Btu/hr Occupants 10 Occupants X 155 Btuh/occ. = 149 Infiltration: 4,771 X 0.94 X 16.20 X 0.00523 = 378 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 149 Ene Pro 6.3 by EnerqySoft User Number: 6712 RunCode: 2014-10-30714:43:43 /D: Page 36 of 37 1] w RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 10/30/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 473.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 473.0 X 0.0260 X 56.0 = 689 R-21 Wall (W.19.2x6.16) (NE) 105.0 X 0.0690 X 31.0 = 224 R-21 Wall (W.19.24.16) (SE) 320.0 X 0.0690 X 28.6 = 631 R-21 Wall (W.19.2x6.16) (S KO 172.5 X 0.0690 X 32.0 = 381 R-21 Wall (W.19.2x6.16) (NIM 314.0 X 0.0690 X 29.0 = 628 "R-13 Wall 120.0 X 0.1020 X 0.0 = 0 X X = X X X X = Page Total 2,552 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1N (NE) 0.0 X 14.9 + 20.0 X 25.4 = 508 1N (NE) 0.0 X 14.9 + 40.0 X 25.4 = 1,016 1N (NE) 0.0 X 14.9 + 20.0 X 25.4 = 508 112 (SW) 0.0 X 14.9 + 12.5 X 21.1 = 264 113 (NIM 0.0 X 14.9 + 6.0 X 22.3 = 134 X + X = X + X = X + X = X + X = Page Total 2,x29 Internal Gain Btu/hr Occupants 1.4 Occupants X 245 Btuh/occ. =L 348 Equipment 473 Floor Area X 0.50 w/sgft = 807 Infiltration: 1.064 X 0.94 X 23.88 X 42 = ggg Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I I Y QF I A 7,134 U1LDING SAFCETY s Latent Gain DE ulhr Occupants 14 Occupants X I Alr55i' 2M /o' �50vED 220 CONSTRUCTION Infiltration: 4,771 X o.s4 _ X 23.88 X 0.00523 558 Air Sensible CFM ELA AW -fi I /Z _8Y TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 220 Ene Pro 6.3 by Energ YSoft User Number: 6712 Run Code: 2014-10-30T14:43:43 ID: Page 37 of 37 RECEIVED ,CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 OCT 31 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5 -HDA -Jones -14. CF1 R -PRF -01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Custom Res 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Features shown below - 03 Project Location Lot 5, Traditions 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 247 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 4637 15 Number of Zones 6 16 Slab Area (FT2) 4637 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A 21 Glazing Percentage (%) 23.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS ritir under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below - ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.31 1.87 1.44 43.5% Space Cooling 97.35 95.45 1.90 2.0% IAQ Ventilation 1.82 V nP I -o-o; 0.0% Water Heating 5.85 8 _ -17.8% Photovoltaic Offset —0 0.00 -- Compliance Energy Total 108.33 106103 1 r I 1 2.30 2.1% DATEBY Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 ,i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Page 2 of 12 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xm1 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Cathedral Ceiling • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified SEER • Refrigerant Charge Fan Efficacy Watts/CFM HVAC Distribution System Verifications: Duct Sealing • Verified low -leakage ducts located entirely in conditioned space. Domestic Hot Water System Verifications: • —None — 4lf ♦ �'. _ �" f r` ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2)• 146.07 143.77 2.30 1.6% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Custom Res 4637 1 18 6 0 2 Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Description: Title 24 Analysis Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF1 R -PRF -01 Page 3 of 12 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Suite Conditioned HVAC 11 1095 11 DHW Sys 1 Living/Entry/Office Conditioned HVAC 22 1443 12.5 DHW Sys 1 Kitchen/Dining Conditioned HVAC 33 996 10 DHW Sys 1 Bedroom Conditioned HVAC 33 309 10 DHW Sys 1 Bedroom 3 Conditioned HVAC 33 321 10 DHW Sys 1 Casita Conditioned HVAC 44 473 10 DHW Sys 1 Registration Number: 214-N0084442C-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-10-30 14:50:51 Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Description: Title 24 Analysis Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Input File Name: Traditions Lot 5-HDA-Jones-14.xmi CF1 R -PRF -01 Page 4 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) 57d Wall Master Suite R-21 Wall (W.19.2x6.16) 57 specify - 198 96 90 147d Wall Master Suite R-21 Wall (W.19.2x6.16) 147 - specify - 28 0 90 157d Wall Master Suite R-21 Wall (W.19.2x6.16) 157 Right 95 0 90 237d Wall Master Suite R-21 Wall (W.19.2x6.16) 237 - specify - 75 0 90 247d Wall Master Suite R-21 Wall (W.19.2x6.16) 247 Front 130 0 90 327d Wall Master Suite R-21 Wall (W.19.2x6.16) 327 - specify - 494 66.5 90 337d Wall Master Suite R-21 Wall (W.19.2x6.16) 337 Left 165 0 90 R-38 Roof 2 Master Suite R-38 Roof(R.38.2x14.16) 1095 67d Wall Living/Entry/Office R-21 Wall (W19.2x6.16) 67 Back 480 278 90 157d Wall 2 Living/Entry/Office R-21 Wall (W.19.2x6.16) 157 Right 168 25 90 247d Wall 2 Living/Entry/Office R-21 Wall (W19.2x6.16) 247 Front 270 148 90 R-38 Rouf 3 ,Living/Entry/Office �1" R=38 Roof(R.38x14.16)7 1431 67d Wall I Kitchen/Dining r. 13-21 Wall (W.19.2x6.16) j ; 67 ' Back 210 133 90 157d Wall 3 Kitchen/Dining �R-21 Wall (W.19.2x6.16)' 157" ! 720 95 90 247dWall 3 —4Kit6hen/Dining R-21 Wall (W.19.2x6.16) �247_?1/1 u Front 175 0 90 337d Wall 2 Kitchen/Dining R-21 Wall (W.19.2x6.16) 337 Left 65 47 90 R-38 Roof 4 Kitchen/Dining R-38 Roof(R.38.2x14.16) 996 247d Wall 4 Bedroom 2 R-21 Wall (W.19.2x6.16) 247 Front 20 0 90 337d Wall 3 Bedroom 2 R-21 Wall (W.19.2x6.16) 337 Left 168 36 90 R-38 Roof 5 Bedroom 2 R-38 Roof(R.38.2x14.16) 309 67d Wall 3 Bedroom 3 R-21 Wall (W.19.2x6.16) 67 Back 20 0 90 157d Wall 4 Bedroom 3 R-21 Wall (W.19.2x6.16) 157 Right 90 0 90 247d Wall 5 Bedroom 3 R-21 Wall (W. 19.2x6.16) 247 Front 170 0 90 337d Wall 4 Bedroom 3 R-21 Wall (W.19.2x6.16) 337 Left 200 42 90 R-38 Roof 6 Bedroom 3 R-38 Roof(R.38.2x14.16) 321 67d Wall 4 Casita R-21 Wall (W. 19.2x6.16) 67 Back 185 80 90 157d Wall 5 Casita R-21 Wall (W.19.2x6.16) 157 Right 320 0 90 247d Wall 6 Casita R-21 Wall (W.19.2x6.16) 247 Front 185 12.5 90 337d Wall 5 Casita R-21 Wall (W.19.2x6.16) 337 Left 320 6 90 R-38 Roof 7 Casita R-38 Roof(R.38.2x14.16) 473 Registration Number: 214-No084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24. Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFI R -PRF -01 Page 5 of 12 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectan ce Roof Emmittanc a Framin g Factor R-38 Roof Living/Entry/Office R-38 Roof(R.38.2x14.16)1 - specify - 12.1 4 . 0 1 0 1 0 0.1 0.85 0.1 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 0 0.1 0.85 No No Registration Number: 214-No084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-3014:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF1 R -PRF -01 Page 6 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height Width(ft) (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading 1C Window 57d Wall (- specify --57) - -- 1 24.0 0.32 0.23 Insect Screen (default) 1 C 2 Window 57d Wall (- specify -57) - - 1 48.0 0.32 0.23 Insect Screen (default) 1 C 3 Window 57d Wall (- specify -57) - -- 1 24.0 0.32 0.23 Insect Screen (default) 101 Window 327d Wall (- specify -327) - - 1 12.5 0.32 0.23 Insect Screen (default) 102 Window 327d Wall (- specify --327) - -- 1 48.0 0.32 0.23 Insect Screen (default) 103 Window 327d Wall (- specify --327) - -- 1 6.0 0.32 0.23 Insect Screen (default) 1 D Window 67d Wall (Back -67) - - 1 48.0 0.32 0.23 Insect Screen (default) 1E Window 67d Wall (Back -67) -- - 1 230.0 0.32 0.23 Insect Screen (default) 104 Window 157d Wall 2 (Right -157) - -- 1 25.0 0.32 0.23 Insect Screen (default) 1A Window 247d Wall 2 (Front -247) - -- 1 140.0 0.32 0.23 Insect Screen (default) 100 Window 247d Wall 2 (Front -247)_ -. - 1 8.0 0.32 0.23 Insect Screen (default) Skylight Skylight # R-38 Roof (4specify -!157) ' tj V `� 1 4.0 0.51 0.28 Skylight 2 Skylight R-38 Roof (- specify' -157)' „1 4.0 0.51 0.28 Skylight 3 Skylight\ y f `• �Y R-38 Roof (_sp6cify -157) ` ' i �I 41 .i; �I 1i[,� 4.0 0.51 0.28 1G Window 67d Wall 2 (Back -67) 13.3 10.0 1 133.0 0.32 0.23 Insect Screen (default) 105 Window 157d Wall 3 (Right -157) - - 1 25.0 0.32 0.23 Insect Screen (default) 106 Window 157d Wall 3 (Right -157) - - 1 25.0 0.32 0.23 Insect Screen (default) 107 Window 157d Wall 3 (Right -157) - - 1 45.0 0.32 0.23 Insect Screen (default) 1F Window 337d Wall 2 (Left -337) - -- 1 47.0 0.32 0.23 Insect Screen (default) 111 Window 337d Wall 3 (Left -337) -- - 1 36.0 0.32 1 0.23 Insect Screen (default) 109 Window 337d Wall 4 (Left -337) - -- 1 36.0 0.32 0.23 Insect Screen (default) 110 Window 337d Wall 4 (Left -337) - -- 1 6.0 0.32 0.23 Insect Screen (default) 1N Window 67d Wall 4 (Back -67) - -- 1 20.0 0.32 0.23 Insect Screen (default) 1N 2 Window 67d Wall 4 (Back -67) -- -- 1 40.0 0.32 0.23 Insect Screen (default) 1N3 Window 67d Wall 4 (Back -67) - -- 1 20.0 0.32 0.23 Insect Screen (default) 112 Window 247d Wall 6 (Front -247) - - 1 12.5 0.32 0.23 Insect Screen (default) q 113 Window 337d Wall 5 (Left -337) - - 1 6.0 0.32 0.23 Insect Screen (default) Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF. COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF1 R -PRF -01 Page 7 of 12 DOORS 01 02 03 04 Name Side of Building Area (ft2) U -factor Door 247d Wall 3 24.0 0.50 OVERHANGS AND FINS 01 02 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Surface Type Overhang Framing Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent. Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 1G 14 0.1 14 14 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers ;, ``2x4 Top Chord of ", ` f7 Cavity/ Frame: no insul. / 2x4 Top Chrd Attic Roof Cons Attic Roofs Wood Framed ,Ceiling Roof :Fuss @ 24 in. O.0 f ~-,_rnor"e _ Roof Deck: Wood Siding/sheathing/decking - Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board • Cavity/ Frame: R-9.1 /2x4 R-38 Roof(R.38.2xl4.16) Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/ Frame: R-21 / 2x6 R-21 Wall (W.19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof(R.38.2xl4.16)1 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 Roofing: Light Roof (Asphalt Shingle) Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Daterrime: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF1 R -PRF -01 Page 8 of 12 SLAB FLOORS i ! ", I ! 01 ' • . (. `f ' ..�—J 02 r " - .,.� 5 (!( `(f I`03 04 Quality Insulation Installation (QII) 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Covered Slab Master Suite 728 110 None 1 No Hard Surface Slab Master Suite 367 23 None 0 No Covered Slab 2 Living/Entry/Office 174 41 None 0.8 No Hard Surface Slab 2 Living/Entry/Office 1269 131 None 0.8 No Covered Slab 3 Kitchen/Dining 420 65 None 0.8 No Hard Surface Slab 3 Kitchen/Dining 576 32 None 0.8 No Covered Slab 4 Bedroom 2 260 12 None 1 No Hard Surface Slab 4 Bedroom 2 49 7 None 0 No Covered Slab 5 Bedroom 3 193 60 None 1 No Hard Surface Slab 5 Bedroom 3 128 41 None 0 No Covered Slab 6 Casita 345 60 None 1 No Hard Surface Slab 6 .Casita -r-rw�t 1287' y� -may ,C 41 None 0 No BUILDING ENVELOPE -HERS VERIFICATION /') `\. i ! ", I ! 01 ' • . (. `f ' ..�—J 02 r " - .,.� 5 (!( `(f I`03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 05 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS 01 02 03 05 06 07 08 Name Heater Element Type Tank Type ETanklume ) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 0.62 40000-Btu/hr 0 0 DHW Heater 1 Natural Gas Small Storage 0.62 40000-Btu/hr 0 0 Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Description: Title 24 Analysis Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Input File Name: Traditions Lot 5-HDA-Jones-14.xml CF1 R -PRF -01 Page 9 of 12 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A DHW Sys 1 - 1/2 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Multispeed Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC 11 Heat Pump Heat Pump System 1 Yes Heat Pump System 1 Yes Air Distribution System 1 No 1095 HVAC 22 Heat Pump Heat Pump System 2 Yes Heat Pump System 2 Yes Air Distribution 1443 1 -hers -cool Heat Pump System 2 SplitHeatPump 9 HSPF 58000 System 2 16 12.5 HVAC 33 Hea p Heat Pump System stem'3 Yes � �"`�+7'T Heat Pump System 3 Yes Air Distribution 1626 1 -hers -cool Heat Pump System 3 SplitHeatPump System 3 58000 36000 HVAC 44 Heat Pump r ,J Heat Pump System 4 Yes Heat Pump'System 4>�! r' eyes Air Distribution System 4 473 J �. _ t_ L_' _ J i i �I f J'�{ 4 .,� Heat Pump System 4 SplitHeatPump 9 HSPF HVAC - HEATING SYSTEMS: Heat Pumps 01 02 03 04 05 06 07 08 09 10 Heating Cooling Zonally Multispeed HERS Name Type HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pump System 1 SplitHeatPump 9 HSPF 47000 29200 16 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 2 SplitHeatPump 9 HSPF 58000 36000 16 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 3 SplitHeatPump 9 HSPF 58000 36000 16 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 4 SplitHeatPump 9 HSPF 25000 15300 17 13 No No Heat Pump System 1 -hers -cool Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml CFI R -PRF -01 Page 10 of 12 HVAC HEAT PUMP COOLING - HERS VERIFICATION 01 02 03 04 01 02 03 04 05 Name Verified Airflow Verified EER Verified SEER Verified Refrigerant Charge HVAC 11 SCSysRpt 1 350 Not Required Required Verified HVAC 22 SCSysRpt 1 350 Not Required Required Verified HVAC 33 SCSysRpt 1 350 Not Required Required Verified HVAC 44 SCSysRpt 1 350 Not Required Required Verified HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Verified Duct Design Low -leakage Supply Duct Verification Duct Leakage Target (%) Verified Duct Location Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution Air Distribution System conditioned space 6.0 Required Not Required Not Required — System 1 -hers -dist Air Distribution System 2 Ducts located entirely in conditioned space Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution System 2 -hers -dist Air Distribution System 3 Ducts located entirely in 1, Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution conditioned space. ! Y ., Required I 6.0 System 3 -hers -dist Not Required „ �! rj — A ?AtticT Attic None Air Distribution Air Distribution System 4 Ducts located in attic 1 Si F ealed and tested . , 8 �o System 4 -hers -dist -r HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 Duct Leakage Verified Duct Design Low -leakage Name Verification Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System Required 6.0 Required Not Required Not Required — 1 -hers -dist Air Distribution System Required 6.0 Required Not Required Not Required — 2 -hers -dist Air Distribution System Required 6.0 Required Not Required Not Required — 3 -hers -dist Air Distribution System Required I 6.0 Not Required Not Required Not Required i — 4 -hers -dist Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-3014:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xmi CF1 R -PRF -01 Page 11 of 12 HVAC -FAN SYSTEMS 01 ,fl 02 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 ,fl 02 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 HVAC Fan 3 -hers -fan Required 0.58 HVAC Fan 4 -hers -fan g � � � Required 0.58 IAQ (Indoor Air Quality) FANS? I ' , '`� r 'ti, C- _ 01 ,fl 02 .03Ji �. l ) l J, .04 — 05 06 Name w - IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 188.87 0.25 Default 0 Required Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 11 Project Name: Custom Res Calculation Description: Title 24 Analysis Calculation DatefTime: 14:41, Thu, Oct 30, 2014 Input File Name: Traditions Lot 5-HDA-Jones-14.xm1 CF1 R -PRF -01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. .Documentation Author Name: Documentation Author Signature: Tci'�ce�L` Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2014-10-30 14:50:50 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. .3. The building design features or system design features identified on-this.Certificate of Compliance -are -consistent -with the information provided on other applicable compliance documents, worksheets, calculations, plans and sp cifications submtted to`" the enforcement agency for approval with',this building permit application. Responsible Designer Name: ' I , ;'9 (— Responsible Designer Signature: - Tu�ri.�caZ7i Tim Scott J ]!•I�� Company: Date Signed: Scott Design and Title 24, Inc. 2014-10-30 14:50:51 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-NOoa4442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38