BRES2014-1099 Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Custom Residence
Lot 5, Traditions
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
174'11 Irvine Blvd., Suite O
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 92211
(760) 200 4780
FB
ITY OF LA QUINTA
UILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 8Y ob Number:
' Date:
10/30/2014
OCT 312014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
• authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC–www.energysoft.com.
—EnegyPro 6.3 by- Ene Soft User Number. 6712 /D:
fl
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F&OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFI,RF-01
Page 1 of 12
GENERAL INFORMATION
01
Project Name Custom Res
02 This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
02
Calculation Description Title 24 Analysis
03
Project Location Lot 5, Traditions
ENERGY USE SUMMARY
04
A City La Quinta
05
Standards Version Compliance 2014
06
Zip code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3 (651)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 247
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 4637
15 .R�
Number of Zones 6
16
Slab Area (FT2) 4637
17�
Number of Stories 1
18
Addition Cond. Floor Area N/A
e19 -P
Natural Gas Available Yes
20
Addition Slab Area (FT2) N/A
�1
Glazing Percentage (%) 23.2%
AW
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown3below
ENERGY USE SUMMARY
04
05V
06
07
08
Energy Use
(kTDV/ft)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
A,, ;)3.31
1.87
1.44
43.5%
Space Cooling
97.35
95.45
1.90
2.0%
IAQ Ventilation
Q� 1.82
1.82
0.00
0.0%
Water Heating
5.85
` >; t x .•�..- .6.89
-1.04
-17.8%
Photovoltaic Offset
—:001)
LA—at—A
--
0.00lot—
--
Compliance Energy Total
R.�
108.33I
8Llt3i_ 1 06 & S -
' �! Oc
..
2.30
2.1%
.,0
Registration Number: �%!
CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance
APPROVE®
FOR CONSTRUCTION
DATE BY
Registration D
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE O&OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFI,WF-01
Page 2 of 12
I REQUIRED SPECIAL FEATURES I
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Cathedral Ceiling
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications: Q'
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts located entirely in conditioned space
Domestic Hot Water System Verifications:
— None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components ni cluded in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24 Pah 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. 4. 4
Reference E nfer�y Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2)• 146 07 143.77 2.30 1.6%
includes calculated Appliances and Miscellaneous Energy Use (AMEE
�L
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned F o` G—r A Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Custom Res
4837;'
1
18
6
0
2
e®49
Registration Number: 0►
CA Building Energy Efficiency Standards` - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFIWF-01
Page 3 of 12
ZONE INFORMATION
01
02
03
04
05
06 07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1 Water Heating System 2
Master Suite
Conditioned
HVAC 11
1095
11
DHW Sys 1
Living/Entry/Office
Conditioned
HVAC 22
1443
12.5
DHW Sys 1
Kitchen/Dining
Conditioned
HVAC 33
996
10
DHW Sys 1
Bedroom 2
Conditioned
HVAC 33
309
10
DHW Sys 1
Bedroom 3
Conditioned
HVAC 33
321
10
DHW Sys 1
Casita
Conditioned
HVAC 44
4
10
DHW Sys 1
Llw
'®p
v�
`e
q�®
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xm1
CFWF-01
Page 4 of 12
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
57d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
57
- specify -
198
96
90
147d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
147
- specify -
28
0
90
157d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
157
Right
95
0
90
237d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
237
- specify -
75
0
90
247d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
247
Front
130
0
90
327d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
b,327
- specify -
494
66.5
90
337d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
�� 337
Left
165
0
90
R-38 Roof 2
Master Suite
R-38 Roof(R.38.2x14.16) ►.
1095
67d Wall
Living/Entry/Office
R-21 Wall (W.19.2x6.16)�`
67
Back
480
278
90
157d Wall 2
Living/Entry/Office
R-21 Wall (W.19.2x6.6R
157
Right
168
25
90
247d Wall 2
Living/Entry/Office
R-21 Wall (W.19.2x616)
247
Front
270
148
90
R-38 Roof 3
Living/Entry/Office
R-38 Roof(R.382�x,14.16)
1431
67d Wall 2
Kitchen/Dining
R-21 Wall (W.1:9�2x6.16)
67
Back
210
133
90
157d Wall 3
Kitchen/Dining
R-21 Wall,(1/ .19.2x6.16)
157
Right
720
95
90
247d Wall 3
Kitchen/Dining
R-21 Wall (W.19.2x6.16)
247
Front
175
0
90
337d Wall 2
Kitchen/Dining
R-3,1�VVall (W.19.2x6.16)
337
Left
65
47
90
R-38 Roof 4
Kitchen/Dining
R WRoof(R.38.2x14.16)
996
247d Wall 4
Bedroom 2
�,•fra--21 Wall (W.19.2x6.16)
247
Front
20
0
90
337d Wall 3
Bedroom 2
r R-21 Wall (W.19.2x6.16)
r
337
Left
168
36
90
R-38 Roof 5
Bedroom 2
R-38 Roof(R.38.2x14.16)
309
67d Wall 3
Bedroom 3
®` R-21 Wall (W.19.2x6.16)
67
Back
20
0
90
157d Wall 4
Bedroom 3 A_ R-21 Wall (W.19.2x6.16)
157
Right
90
0
90
247d Wall 5
Bedroom 3 '1
R-21 Wall (W.19.2x6.16)
247
Front
170
0
90
337d Wall 4
Bedroom&A _
R-21 Wall (W.19.2x6.16)
337
Left
200
42
90
R-38 Roof 6
Bedroom 3
R-38 Roof(R.38.2x14.16)
321
67d Wall 4
C�a ha
R-21 Wall (W.19.2x6.16)
67
Back
185
80
90
157d Wall 5
4:9asita
R-21 Wall (W.19.2x6.16)
157
Right
320
0
90
247d Wall 6
e► Casita
R-21 Wall (W.19.2x6.16)
247
Front
185
12.5
90
337d Wall 5
Casita
R-21 Wall (W.19.2x6.16)
337
Left
320
6
90
R-38 Roof 7
169V Casita
R-38 Roof(R.38.2x14.16)
473
�,V
Registration Number: �� Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:16
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I&OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml
C
CFORF-01
Page 5 of 12
OPAQUE SURFACES— Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Type
Orientatio
n
Area (W) .
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof
Tilt
(deg)
Roof
Reflectan
ce
Roof
Emmittanc
a
Framin
g
Factor
R-38 Roof
Living/Entry/Office
R-38 Roof(R.38.2x14.16)1
specify- 1
12.1
4
0
0
0
0.1
0.85
0.1
ATTIC
01 02 03 04� 05 06 07
Name Construction Roof Rise Roof Refiectance Roof Emittance Radiant Barrier Cool Roof
.rWw
Attic Attic Roof Cons 0 �A0.1 0.85 No No
Registration Number: A� Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards�- 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:16
CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF&F-01
Page 6 of 12
WINDOWS
01
02
03
04 05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Height
Width(ft) (ft)
Multiplier
Area
(ft2)
U -factor
SHGC
Exterior Shading
1C
Window
57d Wall (- specify -57)
-- -
1
24.0
0.32
0.23
Insect Screen (default)
1 C 2
Window
57d Wall (- specify -57)
-- --
1
48.0
0.32
0.23
Insect Screen (default)
1C 3
Window
57d Wall (- specify --57)
-- -
1
24.0
0.32
0.23
Insect Screen (default)
101
Window
327d Wall (- specify -327)
-- --
1
12.5
0.32
0.23
Insect Screen (default)
102
Window
327d Wall (- specify -327)
< -
1
48.0
0.32
0.23
Insect Screen (default)
103
Window
327d Wall (- specify --327)
-- --
1
6.0
0.32
0.23
Insect Screen (default)
1 D
Window
67d Wall (Back -67)
-,`� --
1
48.0
0.32
0.23
Insect Screen (default)
1 E
Window
67d Wall (Back -67)
-
1
230.0
0.32
0.23
Insect Screen (default)
104
Window
157d Wall 2 (Right -157)
��r- -
1
25.0
0.32
0.23
Insect Screen (default)
1A
Window
247d Wall 2 (Front -247) �� - -
1
140.0
0.32
0.23
Insect Screen (default)
100
Window
247d Wall 2 (Front -247) `'�
-- --
1
8.0
0.32
0.23
Insect Screen (default)
Skylight
Skylight
R-38 Roof (- specify -157) A~
1
4.0
0.51
0.28
Skylight 2
Skylight
R-38 Roof (- specify -157) V
1
4.0
0.51
0.28
Skylight 3
Skylight
R-38 Roof (- specify -157) �10
1 1
4.0
0.51
0.28
1G
Window
67d Wall 2 (Back -67)
13.3 10.0
1
133.0
0.32
0.23
Insect Screen (default)
105
Window
157d Wall 3 (Right-15,tjj
-- --
1
25.0
0.32
0.23
Insect Screen (default)
106
Window
157d Wall 3 (Right --;1,57)
-- -
1
25.0
0.32
0.23
Insect Screen (default)
107
Window
157d Wall 3 (Rig'h-t=157)
- -
1
45.0
0.32
0.23
Insect Screen (default)
1F
Window
337d Wall 2 (Left -337)
-- -
1
47.0
0.32
0.23
Insect Screen (default)
111
Window
337d WaIPl (Left -337)
- --
1
36.0
0.32
0.23
Insect Screen (default)
109
Window
337d= -Wall 4 (Left -337)
-- --
1
36.0
0.32
0.23
Insect Screen (default)
110
Window
337d Wall 4 (Left -337)
- -
1
6.0
0.32
0.23
Insect Screen (default)
1N
Window
_6A Wall 4 (Back -67)
-- -
1
20.0
0.32
0.23
Insect Screen (default)
1 N 2
Window
tF67d Wall 4 (Back -67)
- -
1
40.0 1
0.32
0.23
Insect Screen (default)
1 N 3
Window
1�01 67d Wall 4 (Back -67)
-- --
1
20.0
0.32
0.23
Insect Screen (default)
112
Window
�` w 247d Wall 6 (Front -247)
-- --
1
12.5
0.32
0.23
Insect Screen (default)
113
Window
`1v 337d Wall 5 (Left -337)
- --
1
6.0
0.32
0.23
Insect Screen (default)
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF&F-01
Page 7of12
DOORS
01 02 03 04
Name Side of Building Area (ft) U -factor
Door 247d Wall 3 24.0 0.50
OVERHANGS AND FINS
01
02
03
01
02 03 04
05
06 07 08 09 10
11 12 13 14
Construction Type
Overhang
Total Cavity R -value
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
�
Flap HL DepAt�h
Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
1G
14
0.1
14
14
0 SSC(
0
0
0 1
0
0
0
0
K*
-O
SURFACE CONSTRUCTIONS ♦��
01
02
03
�04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R -value
Assembly Layers
2x43Top Chord of
Cavity/ Frame: no insul. /2x4 Top Chrd
Roof Truss @ 24 in.
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
♦ C
jt
Inside Finish: Gypsum Board
e
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
Ceilings (below attic)
Wood Framed Ceiling]
2x4 @ 16 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
• Cavity/ Frame: R-21 /2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Frame all
2x6 @ 16 in. O.C.
R 21
Exterior Finish: Wood Siding/sheathing/decking
Inside Finish: Gypsum Board
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 Roof(R.38.2xl4.16)1
Cathedral Ceilings
Wfood Framed Ceiling I
2x4 @ 16 in. O.C.
R 38
Roofing: Light Roof (Asphalt Shingle)
0
'ey
Registration Number: t�
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIF.E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE FOOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFF -01
Page 8of12
SLAB FLOORS
V
01
02 * V 03 04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
01
02
03 04
05
06
07
Name
Zone
Area (ft) Perimeter (ft)
Edge Insul. R -value& Depth
Carpeted Fraction
Heated
Covered Slab
Master Suite
728 110
None
1
No
Hard Surface Slab
Master Suite
367 23
None
0
No
Covered Slab 2
Living/Entry/Office
174 41
None
0.8
No
Hard Surface Slab 2
Living/Entry/Office
1269 131
None
0.8
No
Covered Slab 3
Kitchen/Dining
420 65
None
0.8
No
Hard Surface Slab 3
Kitchen/Dining
576 '�32
None
0.8
No
Covered Slab 4
Bedroom 2
260 ��/ 12
None
1
No
Hard Surface Slab 4
Bedroom 2
49 7
None
0
No
Covered Slab 5
Bedroom 3
193 w 60
None
1
No
Hard Surface Slab 5
Bedroom 3
128 41
None
0
No
Covered Slab 6
Casita
345 �� v 60
None
1
No
Hard Surface Slab 6
Casita
12816- 41
None
0
No
FWA
BUILDING ENVELOPE - HERS VERIFICATION
V
01
02 * V 03 04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required
NotAequired Not Required —
A1'
WATER HEATING SYSTEMS
A; �"
02 ob►v
03
04
01
02 03
04
05
06
Name
System Type �� Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW �Pipe Insulation, All Lines
DHW Heater 1
1
.0%
DHW Sys 1
DHW Pipe Insulation, All Lines
DHW Heater 1
2
.0%
w
WATER HEATERS 0
01
02 ob►v
03
04
05
06
07
08
Tank Exterior
p��V
.4
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
DHW Heater 1
NattU al Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
DHW Heater 1
j (Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
.,A
Registration Number: t�
CA Building Energy Efficiency Standa'r'ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 1001
Project Name: Custom Res I Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFORF-01
Page 9 of 12
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A
N/A
N/A
N/A
N/A
N/A
DHW Sys 1 - 1/2
N/A
N/A
N/A
N/A
N/A
N/A
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
�� Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
^� Name Ducted
System
Fan System
Served
HVAC 11
Heat Pump
Heat Pump System 1
Yes#
Heat Pump System 1
Yes
Air DistributionSystem 1
Heat Pump System 1
1095
HVAC 22
Heat Pump
Heat Pump System 2
Yes
Heat Pump System 2
Yes
Air Distribution
System 2
Heat Pump System
1 -hers -cool
1443
HVAC 33
Heat Pump
Heat Pump System 3
(�
Yes
Heat Pump System 3
Yes
Air Distribution
System 3
1626
HVAC 44
Heat Pump
Heat Pump System
Yes
Heat Pump System 4
I
Yes
I
Air Distribution
System 4
No
473
1 -hers -cool
Heat Pump System 3
,A
I
58000
36000
16
12.5
No
HVAC - HEATING SYSTEMS: Heat Pumps
01
02
04 05
06 07
08
09
10
^g03
<�
Heating
Cooling
Zonally
Multispeed
HERS
Name
Type 44
� HSPF/COP Cap 47 Cap 17
SEER EER
Controlled
Compressor
Verification
Heat Pump System 1
SplitHeatPump Av
9 HSPF
47000
29200
16
12.5
No
No
Heat Pump System
1 -hers -cool
Heat Pump System
Heat Pump System 2
SplitHeatPump
*!►
9 HSPF
58000
36000
16
12.5
No
No
1 -hers -cool
Heat Pump System 3
SplitHeatPumpV
9 HSPF
58000
36000
16
12.5
No
No
Heat Pump System
1 -hers -cool
Heat Pump System 4
-��
SplitH�A ump
9 HSPF
25000
15300
17
13
No
No
Heat Pump System
1 -hers -cool
,
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-3014:43:16
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I0OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF06F-01
Page 10 of 12
HVAC HEAT PUMP COOLING - HERS VERIFICATION
01
02
03
04�"�
01
02
03
04
05
Name
Verified Airflow
Verified EER
Verified SEER
Verified Refrigerant Charge
HVAC 11 SCSysRpt 1
350
Not Required
Required
Verified
HVAC 22 SCSysRpt 1
350
Not Required
Required.
Verified
HVAC 33 SCSysRpt 1
350
Not Required
Required
Verified
HVAC 44 SCSysRpt 1
350
Not Required
Required
Verified
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04�"�
05
06
07
08
�-
Verified Duct Design
Low -leakage
jW Supply Duct
Verification
�Xct Leakage Target (%)
Verified Duct Location
Name
Type
Duct Leakage
Insulation R -value,.
Location
Return Duct
Bypass Duct
HERS Verification
—
1 -hers -dist
w.
Air Distribution System 1
Ducts located entirely in
Sealed and tested
♦
8
Conditioned Zone
Conditioned Zone
None
Air Distribution
conditioned space
Air Distribution SystemW
System 1 -hers -dist
Air Distribution System 2
Ducts located entirely in
Sealed and tested8
a
Conditioned Zone
Conditioned Zone
None
Air Distribution
conditioned space
r,
Air Distribution System
Required o%9
6.0
System 2 -hers -dist
Air Distribution System 3
Ducts located entirely in
Sealed and tested
® 8
Conditioned Zone
Conditioned Zone
None
Air Distribution
conditioned space
System 3 -hers -dist
Air Distribution System 4
Ducts located in attic
Sealed and tested
v y 8
Attic
Attic
None
Air Distribution
System 4-0ers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
07
Duct Leakage
�-
Verified Duct Design
Low -leakage
Name
Verification
�Xct Leakage Target (%)
Verified Duct Location
Return Supply
Air Handler
Air Distribution System
Required
6.0
Required
Not Required
Not Required
—
1 -hers -dist
w.
Air Distribution System
Required
0 6.0
Required
Not Required
Not Required
—
2 -hers -dist
_
Air Distribution SystemW
Required �
y 6.0
Required
Not Required
Not Required
—
3 -hers -dist
Air Distribution System
Required o%9
6.0
Not Required
Not Required
Not Required
—
4 -hers -dist
sr
.`0
Registration Number: ,p!
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF*F-01
Page 11 of 12
HVAC - FAN. SYSTEMS
01
02
01
01
02
03
• 04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4 -hers -fan
HVAC FAN.SYSTEMS - HERS VERIFICATION
01
02
01
02A`�
03
Name
VerifiedFanWatt~Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Reguiiced
0.58
HVAC Fan 2-hers-fanRequired
Name
0.58
HVAC Fan 3-hers-fanRequired
IAQ Fan Type
0.58
HVAC Fan 4 -hers -fan
*4� Required
0.58
�0.25
»
0
A~
IAQ (Indoor Air Quality) FANS �v
01
02
03
04
05
06'
IAQ Recovery
Name
. IAQ CFM
,OIAQ Watts/CFM
IAQ Fan Type
Effectiveness(%)
HERS Verification
DwellingUnit
188.87
�0.25
Default
0
Required
Registration Number: q�►
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-10-30 14:43:16
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF*F-01
Page 12 of. 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: /
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
10/30/2014
Address:-
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State ip: Phone:
Palm Desert, CA 92211
%11
(77-60) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT�f
I certify the following under penalty of perjury, under the laws of the State of California: ���
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for�thTM�e building design identified on this Certificate of Compliance.
2.. 1 certify that the energy features and performance specifications identified on this Certificate o�f'Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or.system design features identified on this Certificate of Comp it ance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency f approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Jim Deford . Gj
Company: v
Date Signed:
Helton, DeFord & Associates
Address: ��
License:
17411 Irvine Blvd., Suite O `i
City/State/Zip:
Phone:
Tustin, CA 92780 �4
(909) 957-4550
c
®*
Ap
Registration Number: ,,t►�� Registration Date/Time: HERS Provider: -
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:16
4
4
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
Custom Residence
11013012014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111(a).
110.7: Exterior doors and windows are weather-stripped; all 4oints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form.
§110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor.
§150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor.
*§150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor.
§150.0(f): Air retarding wrap is tested, labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form.
150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U -factor of 0.58.
2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
greater, is exempt from the maximum U -factor requirement.
150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
.Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA.
150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c .
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally
wrapped with insulation havinq an installed thermal resistance of R-12 or greater.
§150.00)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
EnergyPro 6.3 by EnergySoR User Number: 6712 /D: Page 15 of 37
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R
Project Name Date
Custom Residence 10/30/2014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards
Table 120.3-A.
150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150.0 m 10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include
all the following components:
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A qas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p).
Residential Lighting Measures:
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance
with TABLE 150.0-A or TABLE 150.0-B as applicable.
150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c).
150.0 k 1 D: Ballasts for fluorescent lams rated 13 Watts or greater shall be electronic and shall have an output frequency <= 20 kHz.
§150.0(k)1E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not
be required to be controlled by vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 16 of 37
4
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Custom Residence
10/30/2014
150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150.0(k).
150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts
for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with ihe applicable requirements in Sections 110.9, 130.0, 130.2, 130.4 140.7 and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume
no more than five watts of power as determined according to 4130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4, 140.6, and 141.0.
§150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
§150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than
20 percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and a ress.
EnergyPro 6.3 by EnergySoR User Number: 6712 /D: Page 17 of 37
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ustom Residence
Date
10/30/2014
System Name
HVAC 1
Floor Area
1,095
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 621
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 47,000
12,473
1,800 773
14,032
Total Output Btuh 47,000
0
Output Btuh/s ft 42.9
181
159
Cooling System
0
0
Output per System 47,000
0
0 0
0
Total Output Btuh 47,000
0
1,800
0
Total Output Tons 3.9
181
159
Total Output Btuh/s ft 42.9
Total Output s ft/Ton 279.6
12,834
14,351
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 25HCB648/FV4CNB005 32,511
5,031
29,355
Airflow cfm/s ft
1.46
Airflow cfm/Ton 408.5
Outside Air %
0.0%
Total Adjusted System Output 32,511
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
5,031
Aug 3 PM
29,355
Outside Air cfm/s ft 0.00
Note: values above giyen at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
72 OF
72 OF 89 OF 89 OF
fns
Heating Coil Supply Fan
89 OF
1,600 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
70/58°F
70/58°F 51/50°F 51/50°F
c
Cooling Coil Supply Fan 51 / 50 OF
1,600 cfm
49.0% ROOM
70/58°F
Energ Pro 6.3 by Energ Soft
User Number: 6712 Run Code: 2014-10-30T14:43:43 /D:
Page 18 of 37
4
r
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ustom Residence
System Name
HVAC 2
Date
10/30/2014
Floor Area
1,443
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,188
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem 58,000
20,960
2,372
1,081
19,341
Total Output Btuh 58,000
0
Output Btuh/s ft 40.2
303
220
Cooling System
0
0
Output perSystem 56,500
0
0 0
0
Total Output Btuh 56,500
0
2,372
0
Total Output Tons 4.7
303
220
Total Output Btuh/s ft 39.2
Total Output s ft/Ton 306.5
1 21,567
19,780
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 25HCB660/FV4CNB006 35,883
10,123
36,225
Airflow cfm/s ft
1.39
Airflow cfmfTon 424.8
Outside Air %
0.0%
Total Adjusted System Output 35,883
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
10,123
Aug 3 PM
36,225
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
72 OF
72 OF 89 OF ^^ 89 OF
fns
Heating Coil Supply Fan o
2,000 cfm 89 F
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm AL
F
L
70/60°F 53/52°F 53/52°F
Elm
Cooling Coil Supply Fan 53 / 53 OF
2,000 cfm
53.8% ROOM
70 / 59 OF
6.3 by Energ Soft
User Number: 6712 RunCode: 2014-10-30T14:43:43 /D:
Page 19 of 37
C
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence
Date
10/30/2014
System Name
HVAC 3
Floor Area
1,626
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,154
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 58,000
20,236
2,673 1,317
23,506
Total Output Btuh 58,000
0
Output Btuh/s ft 35.7
293
267
Cooling System
0
0
Output perSystem 56,500
0
0 0
0
Total Output Btuh . 56,500
0
293
1 20,821
1 2,673
0
Total Output ons 4.7
267
Total Output Btuh/s ft 34.7
Total Output s ft/Ton 345.3
24,040
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 25HCB660/FV4CNB006 35,657
10,428
36,225
Airflow cfm/s ft
1.23
Airflow cfm/Ton
424.8
Outside Air %
0-00%
Total Adjusted System Output 35,657
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
10,428
Aug 3 PM
36,225
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
F Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
72 OF
72 OF 89 OF 89 OF
f Cil r�
Heating Coil Supply Fan
89 OF
2,000 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
— - — -
Outside Air
0 cfm
70/60°F
70/60°F 53/53°F 53/53°F
� 1],-- �
Cooling Coil Supply Fan 54 / 53 OF
2,000 cfm - --
54.2 % ROOM
70/59°F
Energ Pro 6.3 by EnergySoft
User Number: 6712 Run Code: 2014-10-30714:43:43 ID:
Page 20 of 37
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence
Date
10/30/2014
System Name
HVAC4
Floor Area
473
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 462
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 25,000
7,134
778 272
9,432
Total Output Btuh 25,000
0
Output Btuh/s ft 52.9
412
361
Cooling System
0
0
—Output per S stem 24,000
0
0 0
0
Total Output Btuh 24,000
0
778
0
Total Output Tons 2.0
412
361
Total Output Btuh/s ft 50.7
Total Output s ft/Ton 236.5
7,958
10,153
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Carrier 25HCB624/F4BNF003 14,727
5,117
15,614
Airflow cfm/s ft
1.69
Airflow cfm/Ton
400.0
15,614
Outside Air % 0.0%
Total Adjusted System Output 14,727
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
5,117
Aug 3 PM
Outside Air cfm/s 0.00
ft
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
72 OF
72 OF 105 OF ^^ 105 OF
fQ� �
Heating Coil Supply Fan
105 OF
800 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
70/60 OF
70/61 OF 55/54°F 55/54°F
O
Cooling Coil Supply Fan 55 / 54 OF
800 cfm -- -
57.2 % ROOM
70 / 60 OF
Energ Pro 6.3 by Energ Soft
User Number., 6712 Run Code: 2014-10-30T14:43:43 /D:
Page 21 of 37
•
•
ROOM LOAD SUMMARY
Project Name Date
Custom Residence 10/30/2014
System Name Floor Area
HVAC 1 1,095
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible
Master Suite Master Suite 1 1 621 12,4731 1,800 6211 12,4731 1,800 7731 14,032
PAGE TOTAL
TOTAL`
621
12,473
1,800
773
14,032
6211
12,473
1,800
773
14,032
' Total includes ventilation load for zonal systems. I
EnergyPro 6.3 by Ener_gySoR User Number: 6712 Runcode: 2014-10-30T14:43:43 ID: Page 22 of 37
•
0
0
ROOM LOAD SUMMARY
20,236
2,673
1,317
23,506
1,154
20,236
2,673
Project Name
Custom Residence
23,506
Date
10/30/2014
System Name
HVAC 3
Floor Area
1,626
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM
Sensible
Latent
CFM
Sensible Latent
CFM Sensible
Kitchen/Dining Kitchen/Dining
1 769
13,490
1,637
769
13,490
1,637
795 14,195
Bedroom 2 Bedroom 2
1 169
2,968
508
169
2,968
508
155 2,759
Bedroom 3 Bedroom 3
1 215
3,778
528
215
3,778
5281
367 6, 552
Total includes ventilation load
RunCode:
PAGE TOTAL
TOTAL•
1,154
20,236
2,673
1,317
23,506
1,154
20,236
2,673
1,317
23,506
CJ
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
Date
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Floor Area 1,095.0 ft2
Indoor. Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
_
_
c
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
1,095.0
0.0260
46
1,310
R-21 Wall (W 19.2x6.16)
1,022.5
0.0690
46
3,245
Double Non -Metal Tinted
162.5
0.3200
46
2,392
Slab -On -Grade
perim = 133.0
0.7300
46
4,466
'R-0 Wall
220.0
0.3560
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,095 X
Area
another room
11.00 X 0.267
Height ACH
Page Total
/60] X
AT
11,413
= 2,619
TOTALHOURLY HEAT LOSS FOR ROOM 14,032
EnergyPro 6.3 by EnergySoR User Number: 6712 RunCode: 2014-10-30T14:43:43 /D: Page 26 of 37
•
•
C
ROOM HEATING PEAK LOADS '
Project Name
Custom Residence
Date
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living/Entry/Office
Floor Area 1,443.0ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
46 c
Btu/hr
R-38 Roof(R.38.2x14.16)
1,431.0
X
X
X
0.0260
1,711
Double Metal Tinted Skylight
12.0
0.5100
46
c
282
R-21 Wall (W. 19.2x6.16)
467.0
0.0690
46
c
=
c
=
1,482
Double Non -Metal Tinted
451.0
X
0.3200
46
6,639
Slab -On -Grade
perim = 172.0
X
0.7300
46
5,776
•R-0 Wall
220.0
X
X
X
X
0.3560
0
0
=
=
=
=
=
X
X
X
=
=
X
X
X
=
=
=
X
X
X
X
=
=
=
=
X
X
=
_
=
=
=
X
X
X
X
X
X
=
=
X
=
=
X
X
=
=
X
to another room
12.50 X 0.235
Ceiling Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,443 X
Area
Page Total
/60] X 46
AT
15,890
_ 3,451
TOTAL HOURLY HEAT LOSS FOR ROOM 19,341
EnergyPro 6.3 by EnergySoft User Number 6712 RunCode: 2014-10-30T14:43:43 /D: Page 27 of 37
•
•
EA
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
Date
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Kitchen/Dining
Floor Area 996.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
0.0260 X
0.0690 X
0.3200 X
0.5000 X
0.7300 X
0.1020 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
another room
10.00 X 0.293
Height ACH
AT 'F
Btu/hr
R-38 Roof(R.38.2x14.16)
996.0
46
=
=
1,191
R-21 Wall (W.19.2x6.16)
871.0
46
2,765
Double Non -Metal Tinted
275.0
46
=
4,048
Wood Door
24.0
46
=
552
Slab -On -Grade
perim = 97.0
46
=
3,257
'R-13 Wall
250.0
0
=
0
=
=
=
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 996 X
Area
Page Total
/60] X 46
AT
11,813
= 2,382
TOTAL HOURLY HEAT LOSS FOR ROOM 14,195
EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-10-30T14:43:43 ID: Page 28 of 37
CJ
C
•
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
Date
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2
Floor Area 309.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
Btu/hr
R-38 Roof(R.38.2x14.16)
309.0
0.0260
46
=
=
370
R-21 Wall (W. 19.2x6.16)
152.0
0.0690
46
482
Double Non -Metal Tinted
36.0
0.3200
46
=
530
Slab -On -Grade
perim = 19.0
0.7300
46
=
638
'R-13 Wall
120.0
0.1020
0
=
=
=
0
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 309 X
Area
another room
10.00 X 0.293
Height ACH
Page Total
/.60 ] X 46
AT
2,020
= 739
TOTAL HOURLY HEAT LOSS FOR ROOM 2, 759
EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 2014-10-30T14:43:43 /D: Page 29 of 37
r�
U
r�
L'
ROOM HEATING PEAK LOADS
Project Name
Custom Residence.
Date
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 3
Floor Area 321.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
OT'F
_
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
321.0
0.0260
46
384
R-21 Wall (W.19.2x6.16)
438.0
0.0690
46
1,390
Double Non -Metal Tinted
42.0
0.3200
46
618
Slab -On -Grade
perim = 101.0
0.7300
46
3,392
'R-13 Wall
120.0
0.1020
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 321 X
Area
another room
10.00 X 0.293
Height ACH
Page Total
/60] X
AT
5,784
= 768
TOTAL HOURLY HEAT LOSS FOR ROOM 6,552
EnergyPro 6.3 by.EnergySoft User Number: 6712 RunCode: 2014-10-30T14:43:43 ID: Page 30 of 37
•
•
ROOM HEATING PEAK LOADS
Project Name
Custom Residence
Date
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 473.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
473.0
0.0260
46
566
R-21 Wall (W. 19.2x6.16)
911.5
0.0690
46
2,893
Double Non -Metal Tinted
98.5
0.3200
46
1,450
Slab -On -Grade
perim = 101.0
0.7300
46
3,392
'R-13 Wall
120.0
0.1020
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 473 X
Area
another room
10.00 X 0.293
Height ACH
Page Total
/60] X
AT
8,300
= 1,131
TOTAL HOURLY HEAT LOSS FOR ROOM 9,432
EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-10-30714:43:43 /D: Page 31 of 37
•
0
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
-J.J.O t IY01IIQ Date
Custom Residence 10/30/2014
ROOM INFORMATION DESIGN CONDITIONS
Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,095.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Tempera ure 70 OF Outdoor Dailv Ranae: 34 OF
Ooaoue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
'R-0 Wall
Orientation
(tM
(NE)
(SE)
(SE)
(SIA)
(SK9
(NM
(NW)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,095.01
0.0260
56.0
102.0
0.0690
30.1
28.0
0.0690
29.7
95.0
0.0690
28.6
75.0
0.0690
31.5
130.0
0.0690
32.0
427.5
0.0690
29.5
165.0
0.0690
29.0
220.0
0.356011
0.0
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
n
1C
1C
1C
101
102
103
Orientation
(NE)
(NE)
(NE)
(NW)
(NW)
(NW)
Page Total
Btu/hr
1,594
212
57
187
163
287
I 3,7011
Shaded
Area
GLF
X 14.9
X 14.9
X 14.9
X 14.9
X 14.9
X 14.9
X
X
X 1
+
+
+
+
+
+
+
+
+1
Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
0.0
24.0
24.0 =
24.0 =
0.0
48.0
0.0
24.0
24.0 =
22.3 =
0.0
12.5
0.0
48.0
22.3 =
0.0
6.0
22.3 =
=
=
=
Page Total
Btu/hr
576
1,152
576
279
1,072
134
3,
Internal Gain Btu/hr
Occupants 3.3 Occupants X 245 Btuh/occ. = 805
Equipment 1,095 Floor Area X 0.50 W/gq ft = 1,869
Infiltration: 1.064 AiX 0.94 X 55.27 X 42 = 2,310
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,473
Latent Gain Btu/hr
Occupants 3 3 Occupants X 155 Btuh/occ. = 509
Infiltration: 4,771 X 0.94 X 55.27 X 0.00523 = 1,291
Air Sensible CFM EIA AW
FOR ROOM 509
tnerg)(Pro 6.3 by EneroySoft User Number: 6712 Run Code: 2014-10-30T14:43:43 /D• Page 32 of 37
r 1
LJ
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living/Entry/Office
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,443.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(W) 1,431.0 X 0.0260
X 56.0 =
2,084
R-21 Wall (1N.19.2x6.16)
(NE) 202.0 X 0.0690
X 31.0 =
431
R-21 Wall (W.19.2x6.16)
(SE) 143.0 X 0.0690
X 28.6 =
282
R-21 Wall (W.19.2x6.16)
(SM 122.0 X 0.0690
X 32.0 =
269
'R-0 Wall •
220.0 X 0.3560
X 0.0 =
0
X
X
X
X =
X
X =
X
X =
Page Total
3,066
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btulhr
Skylight
(W) 0.0 X 20.9 +
4.0 X 58.8 =
235
Skylight
(W) 0.0 X 20.9 +
4.0 X 58.8 =
235
Skylight
(W) 0.0 X 20.9 +
4.0 X 58.8 =
235
1D
(NE) 0.0 X 14.9 +
48.0 X 25.4 =
1,219
1E
(NE) 0.0 X 14.9 +
230.0 X 25.4 =
5,640
104
(SE) 0.0 X 14.9 +
25.0 X 17.7 =
442
1A
(SM 0.0 X 14.9 +
140.0 X 21.1 =
2,952
100
(SM 0.0 X 14.9 +
8.0 X 21.1 =
169
X +
X =
Page Total
11,32
Internal Gain
Btulhr
Occupants
4.3 Occupants X 245
Btuh/occ. =
1,061
Equipment
1,443 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.94 X 72.84 X 42 =
3,045
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
20,960
Latent Gain
Btulhr
Occupants
4.3 Occupants X 155
Btuh/occ. =
671
Infiltration: 4.771
X 0.94 X 72.84 X 0.00523 =
1,701
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
671
EnemyPro 6.3 by EneMySoft
User Number: 6712 RunCode: 2014-10-30T14:43:43 ID:
Page 33 of 37
r -1
L.
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Kitchen/Dining
Outdoor Dry Bulb Temperature
112 OF
Floor Area
996.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I. Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(tq 996.0 X 0.0260
X 56.0 =
1,450
R-21 Wall (W.19.2x6.16)
(NE) 77.0 X 0.0690
X 31.0 =
164
R-21 Wall (1N.19.2x6.16)
(SE) 625.0 X 0.0690
X 28.6 =
1,231
R-21 Wall (W.19.2x6.16)
(SW) 151.0 X 0.0690
X 32.0 =
333
Wood Door
(SIM 24.0 X 0.5000
X 32.0 =
384
R-21 Wall (W.19.2x6.16)
(NM 18.0 X 0.0690
X 29.0 =
36
'R-13 Wall
250.0 X 0.1020
X 0.0 =
0
X
X =
X
X =
Page Total
3,599
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
1G
(NE) 71.5 X 14.9 +
61.5 X 25.4 =
2,629
105
(SE) 0.0 X 14.9 +
25.0 X 17.7 =
442
106
(SE) 0.0 X 14.9 +
25.0 X 17.7 =
442
107
(SE) 0.0 X 14.9 +
45.0 X 17.7 =
795
1F
(NW) 0.0 X 14.9 +
47.0 X 22.3 -
1,050
X +
X =
X +
X =
X +
X =
X +1
X =
Page Total
5,35
Internal Gain
Btu/hr
Occupants
3 0 Occupants X 245
Btuh/occ. =
732
Equipment
996 Floor Area X 0.50
w/sgft =
1,700
Infiltration: 1.064
X 0.94 X 50.27 X 42 =
2,101
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,490
Latent Gain
Btu/hr
Occupants
3 0 Occupants X 155
Btuh/occ. =
463
Infiltration: 4,771
X 0.94 X 50.27 X 0.00523 =
1,174
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
463
Ene Pro 6.3 by EerqyS,ft
User Number: 6712 Run Code: 2014-10-30T14:43:43 /D:
Page 34 of 37
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name -
Date
Custom Residence
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area
309.0 fl2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 °F
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2xl4.16)
(lM 309.0 X 0.0260
X 56.0 =
450
R-21 Wall (W.19.2x6.16)
(SM 20.0 X 0.0690
X 32.0 =
44
R-21 Wall (W.19.2x6.16)
(NtM -132.0 X 0.0690
X 29.0 =
264
'R-13 Wall
120.0 X 0.1020
X 0.0 =
0
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
758
Items shown with an asterisk ('),
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
111
(NM 0.0 X 14.9 +
36.0 X 22.3 =
804
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
804
Internal Gain
Btu/hr
Occupants
0.9 Occupants X 245
Btuh/occ. —
227
Equipment
309 Floor Area X 0.50
W/g4 ft =
527
Infiltration: 1.064
X 0.94 X 15.6G X 42 =
652
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
2,968
Latent Gain
Btu/hr
Occupants
0 9 Occupants X 155
Btuh/occ. =
144
Infiltration: 4,771
X 0.94 X 15.60 X 0.00523 =
364
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
144
EneMyPro 6.3 by EneMySoft
User Number: 6712 RunCode: 2014-10-30T14:43:43 /D:
Page 35 of 37
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
321.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(W) - 321.0 X 0.0260
X
56.0 =
467
R-21 Wall (W.19.2x6.16)
(NE) 20.0 X 0.0690
X
31.0 =
43
R-21 Wall (W.19.2x6.16)
(SE) 90.0 X 0.0690
X
28.6 =
177
R-21 Wall (W.19.2x6.16)
(SIM 170.0 X 0.0690
X
32.0 =
375
R-21 Wall (W.19.2x6.16)
(NW) 158.0 X 0.0690
X
29.0 =
316
"R-13 Wall
120.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page Total
1.379
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
109
(NW) 0.0 X 14.9 +
36.0
X 22.3 =
804
110
(NM 0.0 x 14.9 +
6.0
X 22.3 =
134
X +
x =
X +
x =
X +
X =
x +
x =
X +
x =
X +
x _
X +
X =
Page Total
938
Internal Gain
Btu/hr-
tu/hrOccu
Occupants
ants
10 Occupants X 245
Btuh/occ.
=
236
Equipment
321 Floor Area X 0.50
w/sgft
=
548
Infiltration: 1.064
X 0.94 X 16.20 X 42 =
677
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
3,778
Latent Gain
Btu/hr
Occupants
10 Occupants X 155
Btuh/occ.
=
149
Infiltration: 4,771
X 0.94 X 16.20 X 0.00523 =
378
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
149
Ene Pro 6.3 by EnerqySoft
User Number: 6712 RunCode: 2014-10-30714:43:43 /D:
Page 36 of 37
1]
w
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence
10/30/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area
473.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area
U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(W) 473.0 X
0.0260 X 56.0 =
689
R-21 Wall (W.19.2x6.16)
(NE) 105.0
X
0.0690 X 31.0 =
224
R-21 Wall (W.19.24.16)
(SE) 320.0 X
0.0690 X 28.6 =
631
R-21 Wall (W.19.2x6.16)
(S KO 172.5 X
0.0690 X 32.0 =
381
R-21 Wall (W.19.2x6.16)
(NIM 314.0 X
0.0690 X 29.0 =
628
"R-13 Wall
120.0 X
0.1020 X 0.0 =
0
X
X =
X
X
X
X =
Page Total
2,552
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area
GLF
Area GLF
Btu/hr
1N
(NE)
0.0 X 14.9
+ 20.0 X 25.4 =
508
1N
(NE)
0.0 X 14.9
+ 40.0 X 25.4 =
1,016
1N
(NE)
0.0 X 14.9
+ 20.0 X 25.4 =
508
112
(SW)
0.0 X 14.9
+ 12.5 X 21.1 =
264
113
(NIM
0.0 X 14.9
+ 6.0 X 22.3 =
134
X
+ X =
X
+ X =
X
+ X =
X
+ X =
Page Total
2,x29
Internal Gain
Btu/hr
Occupants
1.4 Occupants X
245 Btuh/occ. =L
348
Equipment
473 Floor Area X
0.50 w/sgft =
807
Infiltration: 1.064
X 0.94 X 23.88 X 42 =
ggg
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
I I Y QF I A
7,134
U1LDING SAFCETY s
Latent Gain
DE
ulhr
Occupants
14 Occupants X
I
Alr55i' 2M /o' �50vED
220
CONSTRUCTION
Infiltration: 4,771
X o.s4 _
X 23.88 X 0.00523
558
Air Sensible
CFM ELA
AW -fi
I /Z
_8Y
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
220
Ene Pro 6.3 by Energ YSoft
User Number: 6712 Run Code: 2014-10-30T14:43:43
ID: Page 37 of 37
RECEIVED
,CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 OCT 31 2014
Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5 -HDA -Jones -14.
CF1 R -PRF -01
Page 1 of 12
GENERAL INFORMATION
01
Project Name Custom Res
02
Calculation Description Title 24 Analysis
03 This building incorporates one or more Special Features shown below
-
03
Project Location Lot 5, Traditions
04
A City La Quinta
05
Standards Version Compliance 2014
06
Zip code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3 (651)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 247
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 4637
15
Number of Zones 6
16
Slab Area (FT2) 4637
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) N/A
21
Glazing Percentage (%) 23.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS ritir under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
-
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(kTDV/ft)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
3.31
1.87
1.44
43.5%
Space Cooling
97.35
95.45
1.90
2.0%
IAQ Ventilation
1.82
V nP I
-o-o;
0.0%
Water Heating
5.85
8 _
-17.8%
Photovoltaic Offset
—0
0.00
--
Compliance Energy Total
108.33
106103 1 r I 1
2.30
2.1%
DATEBY
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
,i
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014 Page 2 of 12
Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xm1
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Cathedral Ceiling
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified SEER
• Refrigerant Charge
Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
Duct Sealing
• Verified low -leakage ducts located entirely in conditioned space.
Domestic Hot Water System Verifications:
•
—None — 4lf ♦ �'. _ �" f r`
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2)• 146.07 143.77 2.30 1.6%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Custom Res
4637
1
18
6
0
2
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF1 R -PRF -01
Page 3 of 12
ZONE INFORMATION
01
02
03
04
05
06 07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1 Water Heating System 2
Master Suite
Conditioned
HVAC 11
1095
11
DHW Sys 1
Living/Entry/Office
Conditioned
HVAC 22
1443
12.5
DHW Sys 1
Kitchen/Dining
Conditioned
HVAC 33
996
10
DHW Sys 1
Bedroom
Conditioned
HVAC 33
309
10
DHW Sys 1
Bedroom 3
Conditioned
HVAC 33
321
10
DHW Sys 1
Casita
Conditioned
HVAC 44
473
10
DHW Sys 1
Registration Number: 214-N0084442C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2014-10-30 14:50:51
Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Input File Name: Traditions Lot 5-HDA-Jones-14.xmi
CF1 R -PRF -01
Page 4 of 12
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
57d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
57
specify -
198
96
90
147d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
147
- specify -
28
0
90
157d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
157
Right
95
0
90
237d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
237
- specify -
75
0
90
247d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
247
Front
130
0
90
327d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
327
- specify -
494
66.5
90
337d Wall
Master Suite
R-21 Wall (W.19.2x6.16)
337
Left
165
0
90
R-38 Roof 2
Master Suite
R-38 Roof(R.38.2x14.16)
1095
67d Wall
Living/Entry/Office
R-21 Wall (W19.2x6.16)
67
Back
480
278
90
157d Wall 2
Living/Entry/Office
R-21 Wall (W.19.2x6.16)
157
Right
168
25
90
247d Wall 2
Living/Entry/Office
R-21 Wall (W19.2x6.16)
247
Front
270
148
90
R-38 Rouf 3
,Living/Entry/Office
�1" R=38 Roof(R.38x14.16)7
1431
67d Wall
I Kitchen/Dining r.
13-21 Wall (W.19.2x6.16) j
; 67 '
Back
210
133
90
157d Wall 3
Kitchen/Dining
�R-21 Wall (W.19.2x6.16)'
157" !
720
95
90
247dWall 3
—4Kit6hen/Dining
R-21 Wall (W.19.2x6.16)
�247_?1/1
u Front
175
0
90
337d Wall 2
Kitchen/Dining
R-21 Wall (W.19.2x6.16)
337
Left
65
47
90
R-38 Roof 4
Kitchen/Dining
R-38 Roof(R.38.2x14.16)
996
247d Wall 4
Bedroom 2
R-21 Wall (W.19.2x6.16)
247
Front
20
0
90
337d Wall 3
Bedroom 2
R-21 Wall (W.19.2x6.16)
337
Left
168
36
90
R-38 Roof 5
Bedroom 2
R-38 Roof(R.38.2x14.16)
309
67d Wall 3
Bedroom 3
R-21 Wall (W.19.2x6.16)
67
Back
20
0
90
157d Wall 4
Bedroom 3
R-21 Wall (W.19.2x6.16)
157
Right
90
0
90
247d Wall 5
Bedroom 3
R-21 Wall (W. 19.2x6.16)
247
Front
170
0
90
337d Wall 4
Bedroom 3
R-21 Wall (W.19.2x6.16)
337
Left
200
42
90
R-38 Roof 6
Bedroom 3
R-38 Roof(R.38.2x14.16)
321
67d Wall 4
Casita
R-21 Wall (W. 19.2x6.16)
67
Back
185
80
90
157d Wall 5
Casita
R-21 Wall (W.19.2x6.16)
157
Right
320
0
90
247d Wall 6
Casita
R-21 Wall (W.19.2x6.16)
247
Front
185
12.5
90
337d Wall 5
Casita
R-21 Wall (W.19.2x6.16)
337
Left
320
6
90
R-38 Roof 7
Casita
R-38 Roof(R.38.2x14.16)
473
Registration Number: 214-No084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24. Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFI R -PRF -01
Page 5 of 12
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Type
Orientatio
n
Area (ft2)
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof
Tilt
(deg)
Roof
Reflectan
ce
Roof
Emmittanc
a
Framin
g
Factor
R-38 Roof
Living/Entry/Office
R-38 Roof(R.38.2x14.16)1
- specify -
12.1
4 .
0 1
0 1
0
0.1
0.85
0.1
ATTIC
01 02 03 04 05 06 07
Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Attic Roof Cons 0 0.1 0.85 No No
Registration Number: 214-No084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-3014:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF1 R -PRF -01
Page 6 of 12
WINDOWS
01
02
03
04 05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Height
Width(ft) (ft)
Multiplier
Area
(ft2)
U -factor
SHGC
Exterior Shading
1C
Window
57d Wall (- specify --57)
- --
1
24.0
0.32
0.23
Insect Screen (default)
1 C 2
Window
57d Wall (- specify -57)
- -
1
48.0
0.32
0.23
Insect Screen (default)
1 C 3
Window
57d Wall (- specify -57)
- --
1
24.0
0.32
0.23
Insect Screen (default)
101
Window
327d Wall (- specify -327)
- -
1
12.5
0.32
0.23
Insect Screen (default)
102
Window
327d Wall (- specify --327)
- --
1
48.0
0.32
0.23
Insect Screen (default)
103
Window
327d Wall (- specify --327)
- --
1
6.0
0.32
0.23
Insect Screen (default)
1 D
Window
67d Wall (Back -67)
- -
1
48.0
0.32
0.23
Insect Screen (default)
1E
Window
67d Wall (Back -67)
-- -
1
230.0
0.32
0.23
Insect Screen (default)
104
Window
157d Wall 2 (Right -157)
- --
1
25.0
0.32
0.23
Insect Screen (default)
1A
Window
247d Wall 2 (Front -247)
- --
1
140.0
0.32
0.23
Insect Screen (default)
100
Window
247d Wall 2 (Front -247)_
-. -
1
8.0
0.32
0.23
Insect Screen (default)
Skylight
Skylight
# R-38 Roof (4specify -!157) '
tj V
`�
1
4.0
0.51
0.28
Skylight 2
Skylight
R-38 Roof (- specify' -157)'
„1
4.0
0.51
0.28
Skylight 3
Skylight\
y f `• �Y R-38 Roof (_sp6cify -157) ` '
i �I 41
.i; �I 1i[,�
4.0
0.51
0.28
1G
Window
67d Wall 2 (Back -67)
13.3 10.0
1
133.0
0.32
0.23
Insect Screen (default)
105
Window
157d Wall 3 (Right -157)
- -
1
25.0
0.32
0.23
Insect Screen (default)
106
Window
157d Wall 3 (Right -157)
- -
1
25.0
0.32
0.23
Insect Screen (default)
107
Window
157d Wall 3 (Right -157)
- -
1
45.0
0.32
0.23
Insect Screen (default)
1F
Window
337d Wall 2 (Left -337)
- --
1
47.0
0.32
0.23
Insect Screen (default)
111
Window
337d Wall 3 (Left -337)
-- -
1
36.0
0.32 1
0.23
Insect Screen (default)
109
Window
337d Wall 4 (Left -337)
- --
1
36.0
0.32
0.23
Insect Screen (default)
110
Window
337d Wall 4 (Left -337)
- --
1
6.0
0.32
0.23
Insect Screen (default)
1N
Window
67d Wall 4 (Back -67)
- --
1
20.0
0.32
0.23
Insect Screen (default)
1N 2
Window
67d Wall 4 (Back -67)
-- --
1
40.0
0.32
0.23
Insect Screen (default)
1N3
Window
67d Wall 4 (Back -67)
- --
1
20.0
0.32
0.23
Insect Screen (default)
112
Window
247d Wall 6 (Front -247)
- -
1
12.5
0.32
0.23
Insect Screen (default)
q 113
Window
337d Wall 5 (Left -337)
- -
1
6.0
0.32
0.23
Insect Screen (default)
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF. COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF1 R -PRF -01
Page 7 of 12
DOORS
01 02
03 04
Name Side of Building
Area (ft2) U -factor
Door 247d Wall 3
24.0 0.50
OVERHANGS AND FINS
01
02
01
02 03 04
05 06
07 08 09 10
11 12 13 14
Surface Type
Overhang
Framing
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent.
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
1G
14
0.1
14
14
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R -value
Assembly Layers
;,
``2x4 Top Chord of ",
` f7
Cavity/ Frame: no insul. / 2x4 Top Chrd
Attic Roof Cons
Attic Roofs
Wood Framed ,Ceiling
Roof :Fuss @ 24 in.
O.0 f
~-,_rnor"e _
Roof Deck: Wood Siding/sheathing/decking
- Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
• Cavity/ Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/ Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 Roof(R.38.2xl4.16)1
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
Roofing: Light Roof (Asphalt Shingle)
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Daterrime: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF1 R -PRF -01
Page 8 of 12
SLAB FLOORS
i ! ", I !
01 ' • . (. `f
' ..�—J 02 r " -
.,.� 5 (!( `(f I`03 04
Quality Insulation Installation (QII)
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R -value& Depth
Carpeted Fraction
Heated
Covered Slab
Master Suite
728
110
None
1
No
Hard Surface Slab
Master Suite
367
23
None
0
No
Covered Slab 2
Living/Entry/Office
174
41
None
0.8
No
Hard Surface Slab 2
Living/Entry/Office
1269
131
None
0.8
No
Covered Slab 3
Kitchen/Dining
420
65
None
0.8
No
Hard Surface Slab 3
Kitchen/Dining
576
32
None
0.8
No
Covered Slab 4
Bedroom 2
260
12
None
1
No
Hard Surface Slab 4
Bedroom 2
49
7
None
0
No
Covered Slab 5
Bedroom 3
193
60
None
1
No
Hard Surface Slab 5
Bedroom 3
128
41
None
0
No
Covered Slab 6
Casita
345
60
None
1
No
Hard Surface Slab 6
.Casita
-r-rw�t 1287' y� -may ,C 41
None
0
No
BUILDING ENVELOPE -HERS VERIFICATION /')
`\.
i ! ", I !
01 ' • . (. `f
' ..�—J 02 r " -
.,.� 5 (!( `(f I`03 04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage ACH @ 50 Pa
Required
Not Required
Not Required —
WATER HEATING SYSTEMS
01
02
03
05
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
.0%
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
2
.0%
WATER HEATERS
01
02
03
05
06
07
08
Name
Heater Element Type
Tank Type
ETanklume
)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
0.62
40000-Btu/hr
0
0
DHW Heater 1
Natural Gas
Small Storage
0.62
40000-Btu/hr
0
0
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CF1 R -PRF -01
Page 9 of 12
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A
N/A
N/A
N/A
N/A
N/A
DHW Sys 1 - 1/2
N/A
N/A
N/A
N/A
N/A
N/A
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Multispeed
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC 11
Heat Pump
Heat Pump System 1
Yes
Heat Pump System 1
Yes
Air Distribution
System 1
No
1095
HVAC 22
Heat Pump
Heat Pump System 2
Yes
Heat Pump System 2
Yes
Air Distribution
1443
1 -hers -cool
Heat Pump System 2
SplitHeatPump
9 HSPF
58000
System 2
16
12.5
HVAC 33
Hea p
Heat Pump System stem'3
Yes �
�"`�+7'T
Heat Pump System 3
Yes
Air Distribution
1626
1 -hers -cool
Heat Pump System 3
SplitHeatPump
System 3
58000
36000
HVAC 44
Heat Pump r
,J
Heat Pump System 4
Yes
Heat Pump'System 4>�!
r' eyes
Air Distribution
System 4
473
J �. _
t_
L_' _ J i i �I f J'�{ 4
.,�
Heat Pump System 4
SplitHeatPump
9 HSPF
HVAC - HEATING SYSTEMS: Heat Pumps
01
02
03 04 05
06 07
08
09
10
Heating
Cooling
Zonally
Multispeed
HERS
Name
Type
HSPF/COP Cap 47 Cap 17
SEER EER
Controlled
Compressor
Verification
Heat Pump System 1
SplitHeatPump
9 HSPF
47000
29200
16
12.5
No
No
Heat Pump System
1 -hers -cool
Heat Pump System 2
SplitHeatPump
9 HSPF
58000
36000
16
12.5
No
No
Heat Pump System
1 -hers -cool
Heat Pump System 3
SplitHeatPump
9 HSPF
58000
36000
16
12.5
No
No
Heat Pump System
1 -hers -cool
Heat Pump System 4
SplitHeatPump
9 HSPF
25000
15300
17
13
No
No
Heat Pump System
1 -hers -cool
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis
Input File Name: Traditions Lot 5-HDA-Jones-14.xml
CFI R -PRF -01
Page 10 of 12
HVAC HEAT PUMP COOLING - HERS VERIFICATION
01
02
03
04
01
02
03
04
05
Name
Verified Airflow
Verified EER
Verified SEER
Verified Refrigerant Charge
HVAC 11 SCSysRpt 1
350
Not Required
Required
Verified
HVAC 22 SCSysRpt 1
350
Not Required
Required
Verified
HVAC 33 SCSysRpt 1
350
Not Required
Required
Verified
HVAC 44 SCSysRpt 1
350
Not Required
Required
Verified
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Verified Duct Design
Low -leakage
Supply Duct
Verification
Duct Leakage Target (%)
Verified Duct Location
Name
Type
Duct Leakage
Insulation R -value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located entirely in
Sealed and tested
8
Conditioned Zone
Conditioned Zone
None
Air Distribution
Air Distribution System
conditioned space
6.0
Required
Not Required
Not Required
—
System 1 -hers -dist
Air Distribution System 2
Ducts located entirely in
conditioned space
Sealed and tested
8
Conditioned Zone
Conditioned Zone
None
Air Distribution
System 2 -hers -dist
Air Distribution System 3
Ducts located entirely in
1, Sealed and tested
8
Conditioned Zone
Conditioned Zone
None
Air Distribution
conditioned space.
!
Y
.,
Required
I
6.0
System 3 -hers -dist
Not Required
„ �! rj
—
A
?AtticT
Attic
None
Air Distribution
Air Distribution System 4
Ducts located in attic
1
Si
F ealed and tested .
, 8
�o
System 4 -hers -dist
-r
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
07
Duct Leakage
Verified Duct Design
Low -leakage
Name
Verification
Duct Leakage Target (%)
Verified Duct Location
Return Supply
Air Handler
Air Distribution System
Required
6.0
Required
Not Required
Not Required
—
1 -hers -dist
Air Distribution System
Required
6.0
Required
Not Required
Not Required
—
2 -hers -dist
Air Distribution System
Required
6.0
Required
Not Required
Not Required
—
3 -hers -dist
Air Distribution System
Required
I
6.0
Not Required
Not Required
Not Required
i
—
4 -hers -dist
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-3014:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Custom Res Calculation Date/Time: 14:41, Thu, Oct 30, 2014
Calculation Description: Title 24 Analysis Input File Name: Traditions Lot 5-HDA-Jones-14.xmi
CF1 R -PRF -01
Page 11 of 12
HVAC -FAN SYSTEMS
01
,fl 02
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
,fl 02
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
HVAC Fan 3 -hers -fan
Required
0.58
HVAC Fan 4 -hers -fan g
� � � Required
0.58
IAQ (Indoor Air Quality) FANS? I ' , '`� r 'ti, C- _
01
,fl 02
.03Ji �. l
) l J, .04 —
05
06
Name
w -
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
DwellingUnit
188.87
0.25
Default
0
Required
Registration Number: 214-N0084442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
11
Project Name: Custom Res
Calculation Description: Title 24 Analysis
Calculation DatefTime: 14:41, Thu, Oct 30, 2014
Input File Name: Traditions Lot 5-HDA-Jones-14.xm1
CF1 R -PRF -01
Page 12 of 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
.Documentation Author Name:
Documentation Author Signature:
Tci'�ce�L`
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2014-10-30 14:50:50
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
.3. The building design features or system design features identified on-this.Certificate of Compliance -are -consistent -with the information provided on other applicable compliance documents,
worksheets, calculations, plans and sp cifications submtted to`" the enforcement agency for approval with',this building permit application.
Responsible Designer Name: ' I , ;'9 (—
Responsible Designer Signature: -
Tu�ri.�caZ7i
Tim Scott
J ]!•I��
Company:
Date Signed:
Scott Design and Title 24, Inc.
2014-10-30 14:50:51
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 214-NOoa4442C-000000000-0000 Registration Date/Time: 2014-10-30 14:50:51 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-10-30 14:43:38