11-0606 (AR) Title 24I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Mr. & Mrs. Chuck Lineberger 78-216 Lago La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 RBC EIVED Qv- 6-0-doeb CITY 6F ---LA QUINTA OCT 31 2011 BUILDING & SAFETY DEPT. APPROVED sem: FOR CONSTRUCTION Job Number: DATE f1 J61_ -IOU by I C40 *,W, sqrt&, AR AVNt,,em' Date: 10/28/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro_5.1 by EnergySoft User Number. 6712 RunCode: 2011-10-28715:02:54 ID: C C. PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Chuck Lineberger Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 10/28/2011 Project Address 78-216 Lago La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 2,946 Addition 400 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-11 2,522 Existing Wall Wood Framed R-11 1,194 Existing Door Opaque Door None 48 Existing Slab Unheated Slab -on -Grade None 2,946 Perim = 289' Existing Roof Wood Framed Attic R-30 384 New Wall Wood Framed R-13 244 New Door Opaque Door None 20 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 8.0 0.800 0.39 none none None New Skylight 8.0 0.800 0.39 none none None New Skylight 8.0 0.800 0.39 none none None New Right (NE) 201.0 0.550 0.67 none none Bug Screen Existing Front (SE) 85.2 0.550 0.67 none none Bug Screen Existing Left (SIA) 24.0 0.550 0.67 none none Bug Screen Existing Skylight 8.0 0.800 0.39 none none None New Skylight 8.0 0.800 0.39 none none None New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing 1 Split Heat Pump 8.50 HSPF Split Heat Pump 14.7 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING (fit . Type Gallons Min. Eff Distribution Status P Energ Pro 5.1 by EnergySoft User Number.' 6712 RunCode: 2011-10-28T15:02:54 ID: Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. & Mrs. Chuck Lineberger Building Type 0 Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 11012812011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemvPro 5.1 by EnemySoft User Number., 6712 RunCode: 2011-10-28715:02:54 ID: Page 4 of 11 17- 17- PERFORMANCECERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date Mr. & Mrs. Chuck Lineberger ❑ Multi Family m Existing+ Addition/Alteration 11012812011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 7.08 6.35 0.74 Space Cooling 140.50 116.35 24.14 Fans 29.70 24.94 4.76 Domestic Hot Water 12.54 12.54 0.00 Pumps 0.00 0.00 0.00 Totals 189.82 160.18 29.64 Percent Better Than Standard: 15.6% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 120 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 408 85 Fuel Available at Site: Natural Gas (SK0 552 24 Raised Floor Area: 0 (Nw) 408 0 Slab on Grade Area: 2.946 (NE) 448 201 Average Ceiling Height: 10.0 Roof 2,946 40 Fenestration Average U-Factor: 0.55 TOTAL: 350 Average SHGC: 0.67 Fenestration/CFA Ratio: 11.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, �IK 10/2 11 Address 77-085 Michigan Drive Name Jon Scott Citv/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting Address 77-622 Country Club Dr. Suite O Name Robert Pitchford I City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-10-28T15:02:54 /D: Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Chuck Lineberger Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 0/28/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 2,522 0.079 R-11 0 0 Existing 4.2.1-A2 Existing Residence Wall 247 0.110 R-11 30 90 Existing 4.3.1-A2 Existing Residence Wall 275 0.110 R-11 120 90 Existing 4.3.1-A2 Existing Residence Door 48 1.450 None 1 120 90 Existing 4.5.1-A1 Existing Residence Wall 160 0.110,R-11 120 90 Removec 4.3.1-A2 Existing Residence Wall 264 0.110 R-11 210 90 Existing 4.3.1-A2 Existing Residence Wall 54 0.110 R-11 210 90 Removec 4.3.1-A2 Existing Residence Wall 408 0.110 R-11 300 90 Existing 4.3.1-A2 Existing Residence Wall 90 0.110 R-11 300 90 Removec 4.3.1-A2 Existing Residence Slab 2,546 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 384 0.032 R-30 0 0 New 4.2.1-A8 Atrium Enclosure Wall 244 0.102 R-13 210 90 New 4.3.1-A3 Atrium Enclosure Door 20 1.450 None 210 90 New 4.5.1-A1 Atrium Enclosure Slab 400 0.730 None 0 180 Existing 4.4.7-A1 Atrium Enclosure FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor' SHGC Azm Status GlazingType Location/Comments 1 Skylight 8.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted Skylight Existing Residence 2 Skylight 8.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted SkyLight Existing Residence 3 Sk li ht 8.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted Sk Li ht Existing Residence 4 Window 67.0 0.550 Default 0.67 Default 30 Existing Double Non Metal Clear Existing Residence 5 Window 67.0 0.550 Default 0.67 Default 30 Existing Double Non Metal Clear Existing Residence 6 Window 67.0 0.550 Default 0.67 Default 30 Existing Double Non Metal Clear Existing Residence 7 Window 40.2 0. 5501 Default 0.67 Default 120 Existing Double Non Metal Clear Existing Residence Wndow 24.0 0.550 Default 0.67 Default 120 Existing Double Non Metal Clear Existing Residence •8 9 10 Window Window 15.0 0.550 Default 6.0 0.550 Default 0.67 Default 0.67 Default 120 Existing Double Non Metal Clear 120 Existing Double Non Metal Clear Existing Residence Existing Residence 11 Wndow 64.0 0.550 Default 0.67 Default 120 Removed I Double Non Metal Clear Existing Residence 12 Window 24.0 0.550 Default 0.67 Default 210 Existing Double Non Metal Clear Existing Residence 13 Window 64.0 0.550 Default 0.67 Default 210 Removed Double Non Metal Clear Existing Residence 14 Window 21.0 0.550 Default 0.67 Default 210 Removed Double Non Metal Clear Existing Residence 15 Window 21.0 0.550 Default 0.67 Default 210 Removed Double Non Metal Clear Existing Residence 16 Window 6.0 0.550 Default 0.67 Default 300 Removed Double Non Metal Clear Existing Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Overhang Left Fin Right Fin Len Hat LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 None 1.00 3 None 1.00 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 • EneMyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2011-10-28T15:02:54 ID: Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Chuck Lineberger Building Type m Single Family 0 Addition Alone 0 Multi Family m Existing+ Addition/Alteration I Date 10/28/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC4 Azm Status Glazing Type Location/Comments 17 Mndow 64.0 0.550 Default 0.67 1 Default 3001 Removed Double Non Metal Clear Existing Residence 18 Skylight 8.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted SkyLight Atrium Enclosure 19 Sk li ht 8.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted Sk Light Atrium Enclosure (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 None 1.00 19 None 1.00 • EnecovPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-10-28715:02:54 /D: Pae 7 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. &Mrs. Chuck Lineberger Building Type © Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration IDate 11012812011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built HVAC Existing Existing Residence 2,546 25,460 1960 HVAC 1 Atrium Enclosure 400 4,000 Totals 400 0 2,546 0 HVAC SYSTEMS System Name at . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC Existing 1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC 1 1 Split Heat Pump 8.50 HSPF Split Heat Pump 14.7 SEER Setback New • HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location —R -Value Ducts Tested? Status HVAC Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ New WATER HEATING SYSTEMS S stem Name at . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 5 a —I System Name Pipe Length Pipe Diameter Insul. Thick. Ot . FHP Plenum Outside Buried ❑ r EnergyPro 5.1 Z—y EnergySoft User Number.' 6712 RunCode: 2011-10-28T15:02:54 ID: Page 8 of 11 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name r. & Mrs. Chuck Lineberger Date 10/28/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150 (f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-10-28T15:02:54 /D: Page 9 of 11 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date r. & Mrs. Chuck Lineberger 10/28/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySofi User Number., 6712 RunCode: 2011-10-28T15:02:54 /D: Page 10 of 11 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date r. & Mrs. Chuck Lineberger 10/28/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California'Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number.' 6712 RunCode: 2011-10-28715:02:54 ID: Page 11 of 11