14-130 (SFD) Title 24Title 24 Report
CLEC Approved-2gl l Building Energy Efficiency,
�St*rjdards
Job Name
Morris Residence (2013 Standards)
Lot 128, Avenida La Jarita
La Quinta, CA 92253
Prepared For
Rios Designs, Designer
Roper Morris, Builder.
Prepared By
Dave Bricker
Energy Consultant
11112013A
EnergyPro Version 6.3
LEDs I CITYOF UINTA
a N3SOfl),IdjTjQWDEPT.
f R0 ED
FO
CAL TITLE 24 REPORTS NCI CERTIFIED AIR B R CTION
P.O. Box 6705 LA QUINTA, CA 92248 760-54,1-9025 i 175-47
)ATE
CHEERS & CALCERTS CERTIFIED HERS RATER DAVE�CKER NERSzYD-S NET CABEC-EERT FIED-EFS ST
N
EDS-ENERGY DRIVEN SOLUTIONS INC
Note to Plan Checker and Inspector
Project Name: Morris Residence (2013 Standards)
Job Number: 11112014A
Project Designer: Rios Designs
This project EXCEEDS 2013 Title 24 Standards by 17.8%
Required Special Features:
• Ducts with high level of insulation
• Cool Roof
• Window overhangs and/or fins
HERS Measures:
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Verified EER
• Verified SEER
• Refrigerant Charge verification
HVAC Distribution System Verifications:
• Fan Efficacy Watts/CFM
• Duct Sealing
• Duct Design - Return
• Duct Design - Supply
Domestic Hot Water Verifications:
• -- None --
ClTy OF LA QUINT
* NEW measures for 2013 Code compliance BUILDING SAFETY DEPT.
& SAF A
APPROVEDPP OVED
CONSTRUCTION
---_ BY
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Roper & Kelly Morris Residence (2013 Standards) : .
Lot 128, Avenida La Jarita
La Quinta, CA 92253
Project Designer:
Rios Designs
49-901 Cinnabar Lane
Coachella, CA 92236
r 760-485-7431
Report Prepared by:
Dave Bricker
Energy Driven Solutions Inc
P. O. Box 6705
La Quinta, CA 92248
760.541.9025
Job Number:
11112014A
Date:
11/17/2014 CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
The EnergyPro computer program has been used to perform the calculations summ arized in • his o Fce(e Tiais pr br gram has approval and is
authorized by the California Energy Commission for use with both the Residentia and NoRQsRderit Vq6-FRWg40NEfficien Standards.
This program developed by EnergySoft, LL www.energysoft.com.
TC
EnergyPro 6.3 by EnergySoft - User Number. 6168 1D-1-1'1 U
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
�EnergyPro 6.3 by EnergySoft Job Number: ID: 11112014A User Number. 6168
1
2
3
13
16
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1 Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis
Input File Name: Morris Residence 2013 Standards run 2.xml
CF1 R -PRF -01
Page 1 of 10
GENERAL INFORMATION
r — "' 7
01 Building Complies with Computer: Performance It 1
01
Project Name Roper & Kelly Morris Residence 2013 Standards run 1
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
Q.
02
Calculation Description Title 24 Analysis
,_,_ ❑
03
Project Location Lot 128, Avenida La Jarita
04
05
F-
04
A City La Quinta
05
Standards Version Compliancq
20414 LIJ
06
Zip code 92253
07
Compliance Manager Version
BEMCmp
g 13T3
08
Climate Zone CZ15
09
Software Version
EnergyPro
.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 900-0
0.0%
12
Project Scope Newly Constructed
13
Number of Dwelling Units
1
Photovoltaic Offset
14
Total Cond. Floor Area (FT2)3407
15
Number of Zones
2
J 0
LL
16
Slab Area (FT 2) 3407
17
Number of Stories
1
U -J Q
18
Addition Cond. Floor Area N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (FTZ) N/A
21
Glazing Percentage (%)
15.5%
COMPLIANCE RESULTS s ' •
r — "' 7
01 Building Complies with Computer: Performance It 1
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
`
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(kTDV/ft)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
2.74
4.54
-1.80
-65.7%
Space Cooling
82.54
62.99
19.55
23.7%
IAQ Ventilation
0.94
0.94
0.00
0.0%
Water Heating
7.96
8.95
-0.99
-12.4%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
94.18
77.42
16.76
17.8%
Registration Number: 214-N0137201A-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-114115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Input File Name: Morris Residence 2013 Standards run 2.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Cool roof
• Window overhangs and/or fins
HERS FEATURE SUMMARY
CFI R -PRF -01
Page 2 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Duct Design -Return
• Duct Design -Supply
Domestic Hot Water System Verifications:
•
..None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2)' 134.41 117.65 16.76 12.5%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (sft)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Roper & Kelly Morris Residence
3407
1
4
2
0
1
2013 Standards run 1
Registration Number: 214-N0137201A-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
W
V
Z
Q
CL 5
�Q
0
t
LL a
0
LAJ '
Q �
LuV �
LL �
H �
OC
V Q
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
BATE BY
N -4
Ln
l0
V
c -I
0
0
v�
E ir
u
w
u-
0 0
0
0 v
Y >
I`O
0
to O.
ar v
z �
CD I
o
0 c
O ,
O
O
o r
0
0
a ,
o
N I
r- I
z.
4�
L 5
E
Z I
L
C �
O ,
Y
m C
c L
N
E
0
y
N
n
O
�
C
d
2
d
m
E
d
-
N
A
�
_
OC
NtmN
A
U)
N
A
U)
O
-
2
=
S
0
0
d
m
3
Lo
y t
U •�
N
o
07 S
�-
Q
16
O
0
O
G
7
N
(`7
O
d
c
N
m
E
N
U
Z
ECD
>'
N
N
N
U
L
w
S
tp
Z
y
CL
v
0
�
0
T
f
c
o
-
c
0
-
C
N
c
5
v
N
o
U
o
U
0
E
E
c
'c
Q
r
2
N
N
0
LL
cO
N
!0
Z
Z_
W
Z
0
N
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
BATE BY
N -4
Ln
l0
V
c -I
0
0
v�
E ir
u
w
u-
0 0
0
0 v
Y >
I`O
0
to O.
ar v
z �
CD I
o
0 c
O ,
O
O
o r
0
0
a ,
o
N I
r- I
z.
4�
L 5
E
Z I
L
C �
O ,
Y
m C
c L
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Input File Name: Morris Residence 2013 Standards run 2.xml
CFI R -PRF -01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (W)
Window Area (W)
Tilt(deg)
Exterior Wall front E 21x
South Zone
R-21 Wall
90
Front
210
120
90
Exterior Wall left N 9x12
South Zone
R-21 Wall
0
Right
108
0
90
Exterior Wall front E 8x1
South Zone
R-21 Wall
90
Front
96
0
90
Exterior Wall left N 6.5x
South Zone
R-21 Wall
0
Right
65
0
90
Exterior Wall front E 12.
South Zone
R-21 Wall
90
Front
125
48
90
Exterior Wall right S 3x1
South Zone
R-21 Wall
180
Left
30
0
90
Exterior Wall front E 5x9
South Zone
R-21 Wall
90
Front
45
0
90
Exterior Wall mech rm N 1
South Zone
R-21 Wall
0
Right
100
0
90
Exterior Wall right S 3x1 2
South Zone
R-21 Wall
180
Left
30
0
90
Exterior Wall rear W 12.8
South Zone
R-21 Wall
270
Back
128
25
90
Exterior Wall rear W 6x9
South Zone
R-21 Wall
270
Back
54
8
90
Exterior Wall rear W 25.7
'South Zone
- R-21 Wall ,'
,270
Back
283
0
90
Garage wall 26.5x9
South Zone»Garage
R-21 Wall (W.21.2x6.16)
239
Roof
South Zone
R-38 Cool Roof Attic w/ra
1514
Exterior Wall rear W 18.3
North Zone
R-21 Wall
270
Back
183
0
90
Exterior Wall left N 80x1
North Zone
R-21 Wall
0
Right
800
81
90
Exterior Wall mech rm N 6
North Zone
R-21 Wall
0
Right
60
0
90
Exterior Wall front E 25.
North Zone
R-21 Wall
0
Right
259
33
90
Exterior Wall right S 26.
North Zone
R-21 Wall
180
Left
268
112
90
Exterior Wall rear W 1x10
North Zone
R-21 Wall
270
Back
10
0
90
Exterior Wall right S 7.9
North Zone
R-21 Wall
180
Left
71
5
90
Exterior Wall rear W 9x9
North Zone
R-21 Wall
270
Back
81
0
90
Exterior Wall right S 12x
North Zone
R-21 Wall
180
Left
120
96
90 -
Roof 2
North Zone
R-38 Cool Roof Attic w/ra
1893
Garage wall front
Garage
Garage Ext Wall
90
Front
213
0
90
Garage wall left
Garage
Garage Ext Wall
180
Left
340
0
90:
Garage wall rear
Garage
Garage Ext Wall
270
Back
233
0
90
Garage Roof
Garage
R-0 Cool Roof Attic w/rad
765
I
Registration Number: 214-N0137201A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2014-11-17 11:31:44
Report Version - CFiR-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-1115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Input File Name: Morris Residence 2013 Standards run 2.xml
CFI R -PRF -01
Page 5 of 10
ATTIC
01 02 03 04 05 06 07
Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Attic Roof Cons 0 0.7 0.8 Yes Yes
WINDOWS
,_ I
`
02
03 04
0 U
01
02
03
04 05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Height
Width(ft) (ft)
Multiplier
Area
(ft)
1.11 -factor
SHGC
Exterior Shading
Door 15080 HS
Window
Exterior Wall front E 21x (Front -90)
15.0 8.0
1
120.0
0.60
0.31
Insect Screen (default)
Door 2) 3080FR
Window
Exterior Wall front E 12. (Front -90)
---- --
1
48.0
0.60
0.31
Insect Screen (default)
Window 5050 XO HS
Window
Exterior Wall rear W 12.8 (Back -270)
---- --
1
25.0
0.54
0.36
Insect Screen (default)
Window 4020 XO HS
Window
Exterior Wall rear W 6x9 (Back -270)
---- ---
1
8.0
0.54
0.36
Insect Screen (default)
Window 4046 XO HS
Window
Exterior Wall left N 80x1 (Right -0)
---- --
1
18.0
0.54
0.36
Insect Screen (default)
Window 5060 XO HS
Window
Exterior Wall left N 80x1 (Right -0)
---- ---
1
30.0
0.54
0.36
Insect Screen (default)
Window 5050 XO HS
2
Window
'-
Exterior Wall left N 80x1 (Right -0)1
I r! t •* f
�- ' ---
1
25.0
0.54
0.36
Insect Screen (default)
Window 2040 SH
Window
, { Exterior Wall left N 80x1 (Right -0) '
-
1 .'
8.0
0.54
0.36
Insect Screen (default)
Window 3660 F
Window
Exterior Wall front E 25. (Right -0)
- - ---
1'
21.0
0.42
0.38
Insect Screen (default)
Window 2020 F
Window
Exterior Wall front E 25. (Right -0)
---- --
1
4.0
0.42
0.38
Insect Screen (default)
/indow 2020 F 2co
Window
Exterior Wall front E 25. (Right -0)
---- --
1
4.0
0.42
0.38
Insect Screen (default)
indow 2020 F 3C ---
Window
Exterior Wall front E 25. (Right -0)
---- - -
1
4.0
0.42
0.38
Insect Screen (default)
indow080 - So
indow
Exterior Wall right S 26. (Left -180)
--- ---
1
64.0
0.60
0.31
Insect Screen (default)
oor 2) 3d90 2z
indow
Exterior Wall right S 26. (Left -180)
--- -
1
48.0
0.60
0.31
Insect Screen (default)
W ndow 26b X -n
indow
Exterior Wall right S 7.9 (Left -180)
--- --
1
5.0
0.54
0.36
Insect Screen (default)
indow 1 S
UT
indow
Exterior Wall right S 12x (Left -180)
12.0 8.0
1
96.0
0.60
0.31
Insect Screen (default)
� itati7►ml
O S C<
,_ I
1
02
03 04
0 U
I :Ma a
Side of Building
Area (ft) U -factor
r 3 80SC
Exterior Wall front E 8x1
24.0 1.00
Door 30 OSC 2
Garage wall 26.5x9
24.0 0.50
Registration Number: 214-N0137201A-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1 Calculation Date/Time: 15:28, Tue, Nov 11, 2014
- Calculation Description: Title 24 Analysis
Input File Name: Morris Residence 2013 Standards run 2.xml
CF1 R -PRF -01
Page 6 of 10
OVERHANGS AND FINS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R -value
01
02
03
04
05
06
07
08 09
10
11
12 13
1 14
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Overhang
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
Left Fin
None
0.8
Right Fin
Slab -on -Grade exposed 2
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Door 15080 HS
9
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 12080 HS
1 10
0.1
10
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R -value
Assembly Layers
07
Name
Zone
2x4 Top Chord of
Perimeter (ft)
Cavity/ Frame: no insul. /2x4 Top Chrd
Carpeted Fraction
Heated
Slab -on -Grade covered
Roof Truss @ 24 in.
156
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
120
None
0.8
No
Slab -on -Grade exposed 2
• Inside Finish: Gypsum Board
1450
235
None
0.8
No
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
- R 21
Exterior Finish: Wood Siding/sheathing/decking
Garage slab
Garage
765
78.5
None
• Inside Finish: Gypsum Board
No '
• Cavity / Frame: R-9.1 / 2x4
R-38 Cool Roof Attic w/ra
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/ Frame: R-21 / 2x6
R-21 Wall (W.21.2x6.16)
Interior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R -value& Depth
Carpeted Fraction
Heated
Slab -on -Grade covered
South Zone
156
16
None
0.8
No
Slab -on -Grade exposed
South Zone
1358
120
None
0.8
No
Slab -on -Grade exposed 2
North Zone
1450
235
None
0.8
No
Slab -on -Grade covered 2
North Zone
443
45
None
0.8
No 1 ,
Garage slab
Garage
765
78.5
None
0
No '
Registration Number: 214-NO1372OIA-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD .
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1 Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: Morris Residence 2013 Standards run 2.xml
CF1 R -PRF -01
Page 7 of 10
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required - Not Required --
WATER HEATING SYSTEMS
'
01
02 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction
DHW Sys 1
DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
` Small Storage ,+
+75�
.r r,.�9.52
75000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01f
02
03
i_ 04 f
! 05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
Cooling System
Name Ducted
� DHW Sys 1 - f )
Fan System
N/A
N/A
N/A
N/A
N/A
N/A
1 :'• II,- r —4 1
HV
C SYSTEII�
0� ` 0 �
02
03
04
05
06
07
Z Qo I
N to
System Type
Heating System
Name Ducted
Cooling System
Name Ducted
Distribution
System
Fan System
Floor Area
Served
outh Zce ^
XJ
Other Heat/Cool
Heating Component 1
Yes
Cooling Component 1
�
Yes
Ai Systemu on
y
1514
orth ZoP h1C,2., —
V v
Other Heat/Cool
Heating Component 2
Yes
Cooling Component 2
Yes
Air Distribution
System 2
1893
Registration Number: 214-N0137201A-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Input File Name: Morris Residence 2013 Standards run 2.xml
CFI R -PRF -01
Page 6 of 10
HVAC - HEATING SYSTEMS
01
02
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Name
Verified Airflow
Efficiency
Verified EER
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
13
16
No
No
Cooling Component
Ducts located in attic
system
8
Attic
Attic
None
1 -hers -cool
Cooling Component 2
SOitAirCond - Split air conditioning
13
16
No
No
Cooling Component
System 1 -hers -dist
system
Ducts located in attic
Sealed and tested
8
Attic
2 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
Cooling Component 2 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R -value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution
System 1 -hers -dist
Air Distribution System 2
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution
System 2 -hers -dist
Registration Number: 214-NO1372OIA-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD'-
Project
ETHOD'-
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1 Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: Morris Residence 2013 Standards run 2.xml
CFI R -PRF -01
Page 9 of 10
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
07
04 '
Duct Leakage
Type
Fan Power (Watts/CFM)
Verified Duct Design
Low -leakage
Name
Verification
Duct Leakage Target (%)
Verified Duct Location
Return Supply
Air Handler
Air Distribution System
Required
6.0
Not Required
Required
Required
-
1 -hers -dist
Air Distribution System
Required
6.0
Not Required
Required
Required
--
2 -hers -dist
HVAC -FAN SYSTEMS
01 ;' j
01
02
03
04 '
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
LL Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION-,,,r,—��-
01 ;' j
, , 02 -
03
Name i
�` VerifiedFanWatt Draw
-
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan �`'�
Required ,
0.58
HVAC Fan 2 -hers -fan
Required
0.58
(rri oor Witua iByTFAR9
D 01 r— i
Dw& A i t
z -J goCn
T1
�>�
Ce
Im c
50 0
z 171D
02 03 04 05 06
IAQ Recovery
IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification
71.57 0.25 Default 0 Required
Registration Number: 214-N0137201A-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Roper & Kelly Morris Residence 2013 Standards run 1: Calculation Date/Time: 15:28, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis
Input File Name: Morris Residence 2013 Standards run 2.xml
CFI R -PRF -01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
David Bricker
Company:
Signature Date:
Energy Driven Solutions, Inc.
2014-11-17 08:46:36
Address:
CEA/HERS Certification Identification (If applicable):
PO Box 6705
R 08-06-207
City/State/Zip:
Phone:
La Quinta, CA 92248
760 541 9025
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name: r
1
Responsible Designer Signature:
�
usEin ours -
Justin Morris i'
Company:
Date Signed:
Roper Morris Construction
2014-11-17 11:31:44
Address:
License:
51200 Calle Paloma
NA
City/State/Zip:
Phone:
La Quinta, CA 92253
760-272-9292
I'
Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility ,for'the'accuracy of the; .
t�»
information.
Registration Number: 214-N0137201A-000000000-0000 Registration Date/Time: 2014-11-17 11:31:44 HERS Provider: CaICERTs inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-1115:31:50
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-IR
Project Name
Date
Roper & Kelly Morris Residence (2013 Standards)
11111712014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form.
§110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the
installation of a Cool Roof is specified on the CF-1 R Form.
*§1 50.0a : Minimum R-30 R-19 for Alterations insulation in wood-frame ceiling orequivalent U-factor.
§150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
*§150.0(c): Minimum R-13 insulation in 2x4 wood-frame wall R-19 in 2x6 orequivalent U-factor.
*§150.0(d): Minimum R-19 insulation in raised wood-frame floor orequivalent U-factor.
§150.0(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-1 R Form.
§150.0(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below.
1. Fenestration, including skylight products, must have a maximum U-factor of 0.58.
2. The weighted average U-factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
greater, is exempt from the maximum U-factor requirement.
§150.0(r) Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0 a 1A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150.00): Heating systems are equipped with thermostats that meet the setback requirements of Section 110.2(c).
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally
wrapped with insulation having an installed thermal resistance of R-12 or greater.
§150.0(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar at g orpt n w ter
tanks have R-12 external insulation R-16 internal insulation
or where the internal ins lati-vdluelndiCaftetll i r f he
tank. BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
EnefgYPro 6.3 by EnergySoft User Number. 6168
ID: I I lr2UMr
of 17
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Roper & Kelly Morris Residence (2013 Standards)
11111712014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards
Table 120.3-A.
§150.00)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
§150.0(m)10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include
all the following components:
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A gas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions: and
shall not use electric resistance heating ora pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§150.0(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150.0
Residential Lighting Measures:
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance
with TABLE 150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)IC: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c).
150.0 k 1 D:`Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz.
§150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not
be re uired.to;be controlled'b .vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number. 6168 ID: 11112014A Page 14 of 17
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Roper & Kelly Morris Residence (2013 Standards)
11111712014
150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k).
150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f:2 or 100 watts
for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume
no more than five watts of power as determined according to §130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4, 140.6, and 141.0.
§150.0(k)12A. In a low-rise multi -family residential building where the total interior cor 1MocLaEgaJa.&single h jmldbng equals 20 nPr
nt
or less of the floor area, permanently installed lighting for the interior common areas il I th�t`� gdf be Wh ¢ I - it
A
or
controlled by an occupant sensor. tt✓✓ I 1 L.K f 1 V �
§150.0(k)12B. In a low-rise multi -family residential building where the total interior co mRUfb0� s@n&e� t®IFE1RTrr& t
an
20 percent of the floor area, permanently installed lighting in that building shall: nn�I-� pp
i. Comply with the applicable requirements in Sections 110.9, 130.0,
130.1, 40.6, anA�'T.0'"aROVED
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensofttERWV7§10ptr in a
ch
space by at least 50 percent. The occupant sensors shall be capable of turning the tic ht fully On and Off from all designed paths o
in ress and egress.
DATE BY
EnergyPro 6.3 by EnergySoft User Number: 6168
of 17
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Roper & Kelly Morris Residence (2013 Standards)
11/17/2014
System Name
Floor Area
South Zone HVAC
1,514
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 905
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 80,000
18,462
1,819 475
18,346
Total Output Btuh 80,000
0
Output Btuh/s ft 52.8
1,066
902
Cooling System
0
0
Output per System 35,500
0
0 0
0
Total Output Btuh 35,500
0
1,819
0
Total Output Tons 3.0
1,066
902
Total Output Btuh/s ft 23.4
Total Output s ft/Ton 511.8
20,593
20,149
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,200
16 SEER 13 EER 80% 3T split
30,156 0
80,000
Airflow cfm/s ft
0.79
Airflow cfm/Ton)
405.6
Outside Air %
0-0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
30,156 0
Aug 3 PM
80,000
Jan 1 AM
Outside Air (cfm/s ft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 67 OF
67 OF 105 OF
0
Outside Air
0 cfm Supply Fan
Heating Coil
104 OF
1,200 cfm
ROOM
67 OF
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78 OF 76/62 OF 76/62°F 55/54°F
Outside Airy._. _.
E
0 �h'
Supply Fan Cooling Coil
56 / 54 OF
i
1,200 cfm
47.8% ROOM
76162 OF
75 / 62 OF
EnergyPio 6:3'by Eh_ gySoft User Number. 6168 RunCode: 2014-11-17T12:04:46
ID: 11112014A Page 16 of 17
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Roper & Kelly Morris Residence (2013 Standards)
Date
11/17/2014
System Name
North Zone HVAC
Floor Area
1,893
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK COIL HTG.
CFM Sensible Latent CFM
Total Room Loads 1,245 25,009 2,274 690
Return Vented Lighting 0
Return Air Ducts 1,444
Return Fan 0
Ventilation 0 0 0 0
Supply Fan 0
Supply Air Ducts 1,444
TOTAL SYSTEM LOAD 27,896 2,274
PEAK
Heating System
Sensible
Output perSystem 80,000
26,404
Total Output Btuh 80,000
Output Btuh/s ft 42.3
1,298
Cooling System
0
Output perSystem 48,000
0
Total Output Btuh 48,000
0
Total Output ons 4.0
1,298
Total Output Btuh/s ft 25.4
Total Output s ff/Ton 473.3
29,000
Air System
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
16 SEER 13 EER 80% 4T split
40,916 0
80,000
Airflow cfm/s ft
0.63
Airflow cfm/Ton
300.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
40,916 0
Aug 3 PM
80,000
Outside Air (cfm/s ft) 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 67 OF
Outside Air
0 cfm Supply Fan
1,200 cfm
67 OF
67 OF 105 OF
Heating Coil
104 OF
ROOM �®
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling
Peak
112/78°F 76/62°F 76/62°F 55/54°F
Outside Air
0 cfm Supply Fan Cooling Coil
1,200 cfm
76 / 62 OF
4 J -d
CITY OF LA QUI
BUILP&P & �D
APP
FOR CONSTRUCTI sz �F
DATE By.
EnergyPro 6.3 by EnergySofl User Number. 6168 RunCode: 2014-11-17712:04:46
--7 .
f 17