10541 (AR) Title 24ENERGY CALCULATIONS FOR:
Wm. Fritz Construction
54-550 Avenida Velasco
La Quinta, CA 92253
PROJECT: Arends Addition
201 sq.ft. Addition
78-009 Lago Drive
La Quinta, CA
.Standard Proposed Compliance
96.14 95.28 +0.86
Single glazing, Vertical Blinds, Walls R.19 Roof R.30, Duct R-4,
Existing Water Heater, Existing HVAC- Furnace SE 78%; SEER 8.9
CF -1R
MF -1R
C -2R
HVAC Sizing
-----------------------------------------------------------------
d f0r-niil 92201
-71'," Cnur)-t.ry Club 'Dr., D U r
619 360-05'335
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-11'--,'
===============================================================================
Project Title.......... ARENDS ADDITION Date........ 01/29/92
Project Address........ 78-009 Lago Drive ---------------------
La Quinta CA | |
Documentation Author... C. Randall-Christensen Building Permit # |
Company................ T-24 Energy Calcs Co. | |
Telephone.............. (619) 360-0535 Plan Check / Date �
. .
' '
Compliance Method...... MICRQPAS3 by Enercomp, Inc. | Field Check/ Date |
Climate Zone........... 15 ---------------------
| MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program-FORM CF-1R �
� User#-MP1017 User-T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
GENERAL INFORMATION
Conditioned Floor Area..... 201 sf
Building Type.............. Single Family Detached
Building Front Orientation. Front Facing 180 deg (S)
Number of Dwelling Units... .11
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade (Package D)
Infiltration Control....... Standard
BUILDING SHELL INSULATION
---------------------------
Component
________________________Component Insul
Type R -value Location/Comments
Wall R-19
Wall R-11
Roof R-30
SlabEdge R-0
Glazing Area # of
Orientation (sf) Panes
___________________ ______ _____
.
Door Back (N) 12.0 1
Skylight Horz 9.0 1
GLAZING
Interior Exterior
Shading Shading
__________ --------------
V Blinds None
none None
Framing
Overhang Type
________ ---------
None
_______None WoodMul
None Metal
THERMAL MASS
--------------
Area
___________Area Thickness Hard Surfaced/
Type (sf) (in) Exposed Location/Comments
____________ ______ _________ ______________ ________________________
SlabOnGrade 201 3.5 No
ASSUMED HVAC SYSTEMS
Assumed Duct Duct
Assumed System Efficiency Location R -value
_______________ ____________ ___---------- _______
�
Gas 0.720 SE Attic R-4
AirCond 8.90 SEER Attic R-4
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
===============================================================================
Project Title.......... ARENDS ADDITION Date........ 01/29/92
| MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -FORM CF -1R |
� User#-MP1017 User -T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
ACTUAL HVAC SYSTEMS
Actual Output Manufacturer and Model #
Actual System ' Efficiency (Btuh) (or approved equal)
_______________ ___________ ________ -------------------------------------
Heating
________________________________Heating __________ Existing
Cooling Existing
Cooling Coil ^ -------�
`
CEC Maximum output for Gas Central Furnaces: 52000 Btuh
WATER HEATING SYSTEMS
Tank R-12 or
# of Vol Greater Manufacturer and Model # Energy
System Type Heat (gal) Blanket (or approved equal) Credits
____________________ ____ _____ _______ ____________________________ ------------
Meets
_________Meets CEC Minimum n/a n/a' Yes Existing None
` SPECIAL FEATURES/REMARKS
---------------------------
This
_______________________This isan 201 sq.ft. addition to an existing 1600 sq.ft. home.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... ARENDS ADDITION Date........ 01/29/92
===============================================================================
| MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -FORM CF -1R �
| User#-MP1017 User -T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
------------------------- _------------------------------------------- __________
COMPLIANCE STATEMENT
----------------------
This
___________________
This certificate of compliance lists the building features and performance
specifications needed to comply with Title 24, Chapter 2-53 and Title 207
Chapter 2, Subchapter 4, Article 1 of the California Administrative code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate to any subsequent purchaser of the building. When
this certificate of compliance is submitted for a single building plan to
be built in multiple orientations, all building conservation features
which vary are indicated in the Special Features/Remarks section.
DESIGNER
Name....
William Fritz
Company.
General Contractor
Address.
54-550 Avenida Velasco
La Quinta CA
Phone...
(619) 564-6402
License.
594854
Signed VJKSxJAAAv? Ann
DOCUMENTATION AUTHOR
OWNER
Name.... Donald Arends
Company.
Address. 78-009 Lago Drive
La Quinta CA
Phone... (619) 564-2729
v -~��
Signed k �*��
' .~~~
(date)
Name.... C. Randall -Christensen Name....
Company. T-24 Energy /Calcs Co. Title...
Address. 79-733 Country Club Dr. Agency..
Bermuda Dunes, CA 92201
Phone... (619) 360-0535 Phone...
/41
SignedSigned
ENFORCEMENT AGENCY
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Paoe 1 MF -0Z.
Project Title.......... ARENDS ADDITION Date........ 01/29/92
Project Address........ 78-009 Lago Drive ---------------------
La Quinta CA
Documentation Author... C. Randall -Christensen | Building Permit # �
Company................ T-24 Energy Calcs Co. � |
Telephone.............. (619) 360-0535 Plan Check / Date |
. .
. .
Compliance Method...... MICROPAS3 by Enercomp, Inc. | Field Check/ Date �
Climate Zone........... 15 ---------------------
===============================================================================
| MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -FORM MF -1R |
| User#-MP1017 User -T224 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
__________________________
Design- Enforce-
er ment
* 2-5352(a): Minimum ceiling insulation R-19 weighted average.
2-5352(b): Loose fill insulation manufacturers labeled R -Value.
* 2-5352(c): Minimum wall insulation in framed walls R-11
weighted average (does not apply to exterior mass walls).
2-5352(k): Slab edge insulation - water absorption rate no
greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
2-5311: Insulation specified or installed meets CEC quality
standards. Indicate type and form.
2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16.
2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and'windows weatherstripped; all joints and
penetrations caulked and sealed.
2-5352(e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards.
2-5352(d): Installation of Fireplaces
1. Masonry and factory -built fireplaces have:
a. Tight fitting, closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R
===============================================================================
Project Title.......... ARENDS ADDITION Date........ 01/29/92
===============================================================================
.
. MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -FORM MF -1R �
� User#-MP1017 User -T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
HVAC AND PLUMBING SYSTEM MEASURES
_________________________________
Design- Enforce-
er ment
2-5352(g) and 2-5303: Space conditioning equipment sizing.-
attach
izing:attach calculations.
2-5352(h) and 2-5315: Setback thermostat on all applicable
heating systems. _
* 2-5316(a): Ducts constructed, installed and insulated per
Chapter 10, 1976 UMC.
2-5316(b): Exhaust systems have damper controls. _
.2-5314(c): Gas-fired space heating equipment has
intermittent ignition devices. _
2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC. _
2-5352(i): Water heater insulation blanket (R-12 or greater) for
storage and backup tanks for solar water heating systems (first
5 feet of pipes closest to tank insulated to R-3 or greater). _
2-5312(Exception I): Pipe insulation on steam and steam
condensate return and recirculating piping. _
2-5318(d): Swimming Pool Heating
1. System has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater.
c. Plumbed to allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
. 4. Time clock.
5. Directional water inlet.
LIGHTING AND APPLIANCE MEASURES
_______________________________
Design- Enforce-
er ment
2-5352(j): Lighting - 25 lumens/watt or greater for
general lighting in kitchens and bathrooms.
'
2-53140): Gas fired appliances equipped with
intermittent ignition devices.
2-5314(a): Refrigerators, refrigerator -freezers,
freezers and fluorescent lamp ballasts certified by the CEC.
COMPUTER METHOD SUMMARY
Page 1 C-2R
===============================================================================
Project Title..........
ARENDS ADDITION
Date........ 01/29/92
Project Address........
78-009 Lago
Drive
---------------------
La Quinta CA
.
.
Documentation Author...
C. Randall-Christensen
! Building Permit #
|
Company................
T-24 Energy
Calcs Co.
|
�
Telephone..............
(619) 360-0535
| Plan Check / Date
.
�
.
Compliance Method......
MICROPAS3 by
Enercomp,
Inc.
| Field Check/ Date
|
Climate Zone...........
15
---------------------
� MICROPAS3 v3.11
File-ARENDS
Wth-CTZ15
Program-FORM
C-2R
If
| User#-MP1017 User-T-24 Energy
_______________________________________________________________________________
Calcs Co.
Run-SngSR19.30.4Fau72.AC8.9
|
=================================================================
=
=-----------------------------
MICROPAS3
___________________________Energy
ENERGY USE
SUMMARY
=
EnergyUse
Standard
Proposed
Compliance =
= (kBtu/sf-yr)
= _______________________
__________
Design
Design
Margin =
= Space Heating..........
14.95
__________
12.68
__________ =
2.27 =
= Space Cooling..........
70.96
72.37
-1.41 =
= Water Heating..........
10.23
10.23
0.00 =
=
=
Total
96.14
______
95.28
________ =
0.86 =
= *** Building complies
=================================================================
with Computer
Performance
=
*** =
GENERAL INFORMATION
---------------------
Conditioned
__________________
Conditioned Floor Area..... 201 sf
Building Type.............. Single Family Detached
Building Front Orientation. Front Facing 180 deg (S)
Number of Dwelling Units... .11
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area.............
Slab -On -Grade Area.........
Glazing Percentage.........
Average Ceiling Height.....
Slab On Grade (Package D)
1
1608 cf
201 sf
201 sf
10.4 % of FA
8 ft
� BUILDING ZONE INFORMATION
--------------------------
Floor
________________________Floor # of Vent Special
Cond- Area Volume Dwell Thermostat Height Vent Area
Zone Type itioned (sf) (cf) Units Type (ft) (sf)
______________ _______ _________ _________ _____ ____________ ______ -----------
ADDITION
________
ADDITION
Residence Yes 201 1608 0.11 Setback 2.0 n/a
^ ^
COMPUTER METHOD SUMMARY Page 2 C -2R
===============================================================================
Project Title .......... ARENDS ADDITION Date........ 01/29/92
===============================================================================
� MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -FORM 0-21--R |
� User#-MP1017 User -T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
OPAQUE SURFACES
THERMAL MASS
Area Thick Heat Conduct- Surface
Mass Type (sf) (in) Cap ivity R -value Location/Comments
_______________ ______ _____ _____ ________ ________ ---------------------------
ADDITION
_________________________ADDITION
1 SlabOnGrade 201 3.5 28.0 0.98 R-2.0
HVAC SYSTEMS
Area
U- Insul
Act
Duct
Solar
Location/
Form 3
R -value
S6rface
____________
(sf)
______
value R-val
_____ _____
Azmth
Tilt
Gains
Comments
Reference
Attic
ADDITION
0.816
`
_____
____
_____ ________________
0.803
--------------
____________ADDITION
1 Wall
92
0.066 R-19
180
90
Yes
None
2 Wall
60
0.066 R-19
270
90
Yes
None
3 Wall
76
0.066 R-19
0
90
Yes
None
4 Wall
132
0.098, R-11
180
90
No
None
5 Roof
192
0.033 R-30
0
0
Yes
None
PERIMETER LOSSES
Length
-----------------
_______________Length F2
Insul
Surface
____________
(ft) Factor
______
R-val
Location/Comments
ADDITION
________
^
.
_______
______________________
6 SlabEdge
'34 0.720
R_O
7 SlabEdge
34 0.500
R-0
'
GLAZING SURFACES
SC
Interior
SC
Area #
of Frame
Open
U-
Act
Glass
Shade
GIs-+.
Surface
___________
(sf) Panes Type
_____
Type
value
Azmth
Tilt Only
Type
Shade
ADDITION
_____
________
______
_____
_____
____ _____
__________
-----
1 Door
12.0
1 WoodMul
Hinged 1.10
0
90 0.60
V Blinds
0.21
2 Skylight
9.0
1 Metal
Slider 1.03
180
0 0.88
none
0.88
THERMAL MASS
Area Thick Heat Conduct- Surface
Mass Type (sf) (in) Cap ivity R -value Location/Comments
_______________ ______ _____ _____ ________ ________ ---------------------------
ADDITION
_________________________ADDITION
1 SlabOnGrade 201 3.5 28.0 0.98 R-2.0
HVAC SYSTEMS
Minimum
Duct
Duct
Duct
System Type
________________
Efficiency
____________
Location
_____________
R -value
Efficiency
ADD I T I 01\1
_______
----------
_________ADDITION
Gas
0.720 SE
Attic
R-4
0.816
'AirCond
8.90 SEER
Attic
R-4
0.803
^
COMPUTER METHOD SUMMARY Page 3 C -2R
===============================================================================
Project Title.......... ARENDS ADDITION Date........ 01/29/92
===============================================================================
� MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -FORM C-21''..., |
| User# --- MP1017 User -T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
WATER HEATING SYSTEMS
_____________________
Capa- R-12 pr Pilot
System # of city Greater Effic- Standby Input Size
Type Heat (gal) Blanket iency Loss Rating (Btuh) Credits
__________ ____ -- -- _______ ___________ ______ ____________ ________ --------
Water Heater to meet minimum CEC Standards
SPECIAL FEATURES/REMARKS
________________________
This is an 201 sq.ft. addition to an existing 1600 sq.ft. home.
' °
^+x
E3
' ^
HVAC SIZING Pane 1 HVAC
Project Title.......... ARENDS ADDITION Date........ 01/29/92
Project Address........ 78-009 Lago Drive ---------------------
La Quinta CA | '
Documentation Author... C. Randall -Christensen | Building Permit # �
Company................ T-24 Energy Calcs Co. | |
Telephone.............. (619) 360-0535 | Plan Check / Date �
' | |
Compliance Method...... MICROPAS3 by Enercomp, Inc. | Field Check/ Date �
Climate Zone........... 15 ---------------------
===============================================================================
| MICROPAS3 v3.11 File-ARENDS Wth-CTZ15 Program -HVAC SIZING �
� User#-MP1017 User -T-24 Energy Calcs Co. Run-SngSR19.30.4Fau72.AC8.9 |
_______________________________________________________________________________
8ENERAL INFORMATION
Floor Area................. 201 sf
Volume..................... 1608 cf
Front Orientation.......... Front Facing 180 deg (S)
Sizing Location............ INDIO
Latitude................... 33.7 degrees
Winter Outside Design...... 29 F
Winter Inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design.....,. 78 F
Summer Range............... 30 F
Shading Used............... Yes
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
----------------------------------
Heating
_______________________________Heating Cooling
Description (Btuh) (8tuh)
_________________________________ ___________ --------------
Opaque
__________Opaque Conduction and Solar...... 3108 1137
Glazing Conduction............... 921 764
Glazing Solar.................... n/a 1313
Infiltration..................... 948 562
Internal Gain.................... n/a 1650
Ducts............................ 498 543
Sensible Load.................... 5475 5968
Latent Load...................... n/a 1194
___________ -------------
Total
__________Total Load 5475 7161
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CEC Maximum output for gas central furnaces only (area weighted SE):
45000 + (100.0 x (0.720 - 0.71) x 7000) = 52000 Btuh