Loading...
0302-117 (SFD) Title 24TITLE .24 REPORT Title 24 Report for: Custom Residence for Mr. John Reynolds Lot 8, Deacon Drive East La Quinta, Ca. 92253 Project Designer: Stoney Creek Design Studio 72-925 Fred Waring Drive, Suite 201 Palm Desert, Ca. 92260 760-341-6997 Report Prepared By: Jack LaFontaine Energy Management Service 41- 485 Adams Street, Unit C Bermuda Dunes, CA 92201 760-360-4631 Job Number: Date: 12/1/2002 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION O D -g BY, The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 5021 TITLE 24 REPORT Title 24 Report for: Custom Residence for Mr. John Reynolds Lot 8, Deacon Drive East La Quinta, Ca. 92253 Project Designer: Stoney Creek Design Studio 72-92.5 Fred Waring Drive, Suite 201 Palm Desert, Ca. 92260 760-34.1-6997 Report Prepared By: Jack LaFontaine Energy Management Service 41- 485 Adams Street, Unit C Bermuda Dunes, CA 92201 760-360-4631 Job Number: Date: 12/1/2002 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 5021 a N � TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary 1 2 3 9 11 19 22 EnergyPro 3.1 By EnergySoft Job Number. User Number. 5021 Certificate of Compliance: Residential (Part 1 of 2) CF -111 Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date Lot 8, Deacon Drive East La Quinta Project Address Building Permit # Energy Management Service 760-360-4631 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,246 fit Average Ceiling Height: 12.5 ft Total Conditioned Slab Area: 3,246 ft2 Building Type: (check one or more) XI Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc. R-38 Roof (R.38.2x4.24) 5/8gyplrile Wood 0.027 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-21 Wall (W.21.2x6.16) 5/8gyp/Stucco Wood 0.059 Exterior Wall R-21 Wall (W.21.24.16) 5/8-5/8gyp Wood 0.057 Exterior Wall Solid Wood Door None 0.387 Exterior Door FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 2.4 0.65 0.40 None ❑ x❑ ❑x❑ Right (Southeast) 54.0 0.35 0.34 Bug Screen x❑ ❑ ❑ x❑ Right (East) 12.5 0.35 0.34 Bug Screen FAI ❑ ❑ x❑ Rear (North) 133.2 0.35 0.34 Bug Screen ❑ X❑ ❑ X❑ Rear (North) 129.7 0.35 0.34 Bug Screen X❑ ❑ ❑ 0 Rear (North) 27.0 0.39 0.26 Bug Screen 0 ❑ ❑ IRI Right (East) 173.1 0.35 0.34 Bug Screen ❑ Q ❑ Q Front (South) 56.0 0.35 0.34 Bug Screen x❑ ❑ ❑ Q Left (West) 48.0 0.35 0.34 Bug Screen 0 ❑ ❑X❑ Left (West) 46.0 0.36 0.29 Bug Screen Q ❑ ❑ 0 Left (West) 16.0 0.48 0.40 Buq Screen ❑ Q ❑ 0 Left (West) 24.0 0.36 0.29 Bug Screen ❑ x❑ ❑ X❑ Run Initiation Time: 11/23/02 17:42:55 Run Code: 1038102175 Ener Pro 3.1 By Ener Soft User Number. 5021 Job Number. Pa e:3 of 24 Certificate of Comoliance: Residential (Part 1 of 2) CF -1 R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date Lot 8. Deacon Drive East La Quinta Project Address Building Permit # Energy Management Service 760-360-4631 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,246 fit Average Ceiling Height: 12.5 ft Total Conditioned Slab Area: 3,246 ft2 Building Type: Orientation (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type FENESTRATION Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (West) 84.0 0.35 0.34 Bug Screen ❑ X❑ ❑ X❑ Front (South) 4.0 0.36 0.29 Bug Screen ❑ X❑ ❑ X❑ Front (South) 88.0 0.35 0.34 Bug Screen ❑ X❑ ❑ X❑ Left (West) 42.0 0.36 0.30 Bug Screen ❑ X❑ ❑ X❑ Rear (North) 60.0 0.39 0.26 Bug Screen ❑ X❑ ❑ Q Right (East) 30.0 0.39 0.26 Bug Screen ❑ X❑ ❑ 0 Rear (North) 225.0 0.66 0.33 Bug Screen X❑ ❑ ❑ Q Left (Northwest) 50.0 0.39 0.26 Bug Screen ❑ X❑ ❑ Q Left (Northwest) 12.5 0.35 0.34 Bug Screen X❑ ❑ ❑ X❑ Rear (Northeast) 71.2 0.35 0.34 Bug Screen ❑ X❑ ❑ X❑ Right (Southeast) 50.0 0.39 0.26 Bug Screen ❑ X❑ ❑ X❑ Right (Southeast) 12.5 0.35 0.34 Bug Screen ❑ X❑ ❑ X❑ Run Initiation Time: 11/23/0217:42:55 Run Code: 1038102175 Ener Pro 3.1 By Ener Soft User Number: 5021 Job Number: Pa e:4 of 24 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date Lot 8. Deacon Drive East La Quinta Project Address Building Permit # Energy Management Service 760-360-4631 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,246 f? Average Ceiling Height: 12.5 ft Total Conditioned Slab Area: 3,246 ftp Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes ! No Yes / No Left (West) 45.0 0.39 0.26 Bug Screen x❑ ❑ ❑X❑ Rear (North) 25.0 0.36 0.29 Bug Screen ❑ X❑ ❑ x❑ Right (East) 25.0 0.36 0.29 Bug Screen x❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ El 0 1 El F] EI 1:1 ❑❑ El El El Run Initiation Time: 11123102 17:42:55 Run Code: 1038102175 Ener Pro 3.1 By Ener Soft User Number: 5021 Job Number. Pa e:5 of 24 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Cantral Furnas 80% AFUE Ducts in Attic 80 Setback HVAC Zone I Harz Fau-Attic Central Furnace 80% AFUE Ducts in Attic 8 0 Setback HVAC 7ong II tloflw Fa i- rar Central Fumarp 80% AFUE Ducts in Attic 8.0 Setback HVAC Zone III. Upflw Fau-Gar Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner Split Air Conditioner Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN 1362-75T75- urge Gas Recirc/Time+Temp 1- 75,100 75 0.79 0.0244 0.0 4N"' 1 For small gas storage (rated inputs of less than or equal to 75,000 Btuthr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btuthr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions code) Documentation Author Name: r i ;��, Name: Jack LaFontaine Title/Firm: Stoney _Creek Design Studr Title/Firm: Energy Management Service Address: 72-925 Fred Waring Drive, Suite 201 Address: 41- 485' Adams Street, Unit C Palm Desert, Ca. 92260 Bermuge ugnes, CA 92201 Telephone: 760-341-6997 Tel o e: 760- 1 Lic. #: Z•0/ ZooZ ignature) (d te) si ature (date) En em ent Agency Name: Title/Firm: Address: Telephone: IEnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:6 of 24 1 Certificate of Comaliance: Residential (Addendum) CF -1 R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC Zone I, Horz Fau-Attic " has R-8.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone I, Horz Fau-Attic " has R-8.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone I, Horz Fau-Attic " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1042 sqft Covered Slab Floor, 3.50" thick at MBR/BR#2/Guest BR/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 525 sqft Exposed Slab Floor, 3.50" thick at MBR/BR#2/Guest BR/Hall The HVAC System "HVAC Zone 11, Upflw Fau-Gar' has R-8.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone 11, Upflw Fau-Gar' has R-8.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone II, Upflw Fau-Gar' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential MASS Design(see C -2R) - Verify Thermal Mass: 1065 sqft Exposed Slab Floor, 3.50" thick at Living/Dining/Kitchen The HVAC System "HVAC Zone III, Upflw Fau-Gar' has R-8.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone III, Upflw Fau-Gar' has R-8.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The UUHVAC System "HVAC Zone III, Upflw Fau-Gar' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential I8Ii1ASS Design(see C -2R) - Verify Thermal Mass: 214 sqft Covered Slab Floor, 3.50" thick at Den/Laun/Powd/Gallery/Hall HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "HVAC Zone I, Horz Fau-Attic " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC Zone I, Horz Fau-Attic " is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC Zone II, Upflw Fau-Gar' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC Zone 11, Upflw Fau-Gar' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC Zone III, Upflw Fau-Gar' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 11/23/0 17:42:55 Run Code: 1038102175 EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:7 of 24 Certificate of Compliance: Residential (Addendum) CF -IR Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )aced on the adequacy of the special justification and documentation submitted. Plan I Field I HIGH MASS Design(see C -2R) - Verify Thermal Mass: 400 sgft Exposed Slab Floor, 3.50" thick at Den/Laun/Powd/Gallery/Hall I I I HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. i ne MERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC Zone III, Upflw Fau-Gar" is using reduced duct leakage to comply and must have diagnostic site testing of dud leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:8 of 24 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a '§ 150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. '§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). '§I50(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(l): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and seated. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. FX § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Baric -up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemallextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:9 of 24 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R r NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] 1150(m): Ducts and Fans 1. Al ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other ductclosure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. ' 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between finer and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. JA §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures © §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§ t 50(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 5021 Job Number. Page:10 of 24 Computer Method Summary 3,246 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor (Part 1 of 3) C -2R Custom _R sorlence for Mr_ .I.phn Reynolds deg Total Fenestration Area: 47.6% Number of Dwelling Units: 1.00 12/U2002 Project Title Number of Stories: 1 Date _Loi 8,_Dear-on _Drive East La Quinta # of Thermostat Vent Zone Name Floor Area Project Address HVAC 7one I Ham Fau-Attic 1iYAC.lonIll_ IOU Eau -Gar HVAC Zone 111„Llpflw Fau-Gar 1 567 1-065 614 Building Permit # Fne vrManagement Service Saiar 760-360-4631 OPAQUE SURFACES Act. DocumWdtation Aut oFi r Telephone plan Check/Date er�etformance Rnnf1.566 0.027 270 _22 15 Field Check/Date Compl ante Method (Package or Computer) ® ❑ Climate Zone Wall 231 0 O5q- _9..0 _9.p_ Source Energy Use Standard Proposed Compliance ❑ (kBtu/sf-yr) Design Design Margin R-21 Wall (W212x6.16)_5/8aw/3tu= Zone I Space Heating 6.20 6.18 0.02 Wall 178 0.052 _180 90 Space Cooling 44.42 43.67 0.74 ❑ Domestic Hot Water 8.78 8.88 -0.10 R-21 Wall (W_ -21 2_x6,1.6) c+/8a__ ypLStucco Zone I Totals 59.39 58.73 0.66 Walt 96 0.050 0 90 Total Conditioned Floor Area: 3,246 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 47.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 40,474 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 3,246 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC 7one I Ham Fau-Attic 1iYAC.lonIll_ IOU Eau -Gar HVAC Zone 111„Llpflw Fau-Gar 1 567 1-065 614 1R 491 048 CnnditinnPri S# -thank _2 n/a 1523 0.33_ Conditioned _Setback__ -2 _n/a 6.754 0`19 Conditioned Setback �2 n/a Saiar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Rnnf1.566 0.027 270 _22 X -E] R-38 Roof (R.38.2x424) 5/$gyy/Tile Zone I Wall_ 30 0 054 135_ _9.0 ® ❑ R-21 Wall (W1 x6 16) 55/8aw/Stucco Zone I Wall 231 0 O5q- _9..0 _9.p_ ❑ R-21 Wall (W 21-2x6 J6) F/8_ yptS_tucco Zone I Wp 211 78 0 Q52 _99_ SSL ❑ R--21 Wall N 21.2x6.Jf))-5L8gypLStucw Zone Wall 49 0.050 90 ❑ R-21 Wall (W212x6.16)_5/8aw/3tu= Zone I Wall 138 0 059 90_ _g0 EX ❑ R-21 Wall (W.21.2x6.16) 5/8g /yp_Stucco Zone I Wall 178 0.052 _180 90 ❑ R-21Wal1p .2I1L 1.2x6 -J6) 5 ypLStusco Znne I Wall_ 65 0.052 --Aa.0 90 ❑ R-21 Wall 21.2x6 161�L$gypLStucC0 7nnP I Wall 182 0 059 270 _90_ ® ❑ R-21 Wall (W_ -21 2_x6,1.6) c+/8a__ ypLStucco Zone I wall 150 ---0-05-9- 97n _9.0_ ❑ R-21 Wall (W21 2x6 16F_y/8aypLS1ucco Zone I Walt 96 0.050 0 90 ❑ R21.Wall pN.21_ W--t6)_518gypLStu= Zone I Walt 6_ 0.050 _279 _90 ❑ .&2_Lwall_ zt.2x816)_518gypLStucco Znne I Wall 69 0 059 -.80 90_ ®❑ R-21 Wall (W 21 2x6 16) 5/8gyp/Stucrl+ Zone I Wall 208 _ 0.056 X7.0 90 ❑ B2'[ -Wall -021W 16) 5L8gypLS.timco Zone I Wall 198 _0=059 270 _go- R-21 Wall (W.212x6Zone I -Wall 136 _0_05.2 o_ 9.0 ®❑ R-21 Wall (Y1/21.2x6 16) 5L$gyplStuc c.o Zone I Wall_ 55. 0_050 90 _9.0_ ® ❑ _2x6_16.)518gypLStucco Zone I Roof - 1063 - -0-W7 _45_ -22 ❑ R3B-Roof (R_382x42415/8 ile_ Zone 11 Walt 84 --JI05Z x.80 90 ❑ R-21 Wall.21.2x6.16) 5/8 5/Sayrf Zone IL Door 27 0.387 180 _90 ❑ 1 Solid Wood Door Zone 11 Wall 109 0.057 _0 -90 ❑ R-21 Wall (W.212x6 16)/_5 8- +18gyp Zone II Wall 46_ _0.052 _315_ _90 IN El R-21 Wall (w -2j -2x6.16) 5L8-5/agyp_ Zone u Wall 32 _0_05.2 __0 90_ ® ❑ R-21 Wall (yv 21 1x616) 5/8-5L80yp Zone 1I - Wall 32 _0-57_ 45. 90 EX ❑ .R31 Wall pN-21.2x6 16)5 8-5L8gyp_ Zone 11 Wall 32 0957 _90_ 90 ❑ R-21 Wall (W.21.2x6.1 ) 518=5/8gyp_ Zone II Wall 46 0.9.52 _135 90 ❑ R-21 Wall (W.21_ x6 16) 5/8-5/8gy- Zone -Wall-�610.957- _90 9.0 ❑ -11 R2LIN_all(W_21_2x6_.16.) 5L8-51.8gyp Zone II Roof 614 0.027 90 _22 ❑ R-38 Roof (R 38 2x4-24) 518gyp/T*le-- Zone III Wall- 40 0-057 180 90_ ❑ R-21 Wall (y1(.21.2x6 16) 5/8-518gyp_ Zone III EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Pace: 11 of 24 1 Computer Method Summary (Part 1 of 3) C -2R Custom Residence for Mr John—Rv/2 _ennitls 12/1002 Project Title '— Date 1 of 8 np-2con nr*vp- Fast 1 2 Qiionta Project Address Building Permit # FneravMane Pment gprvice 760-360-4631 Plan Check/Date Docum� tation AutFfror Telephone Gomouter Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 6.20 6.18 0.02 Space Cooling 44.42 43.67 0.74 Domestic Hot Water 8.78 8.88 -0.10 Totals 59.39 58.73 0.66 Percent better than Standard: 1.1% BUILDING COMPLIES Total Conditioned Floor Area: 3,246 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 47.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 40,474 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 3,246 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Act Type Area U -Fac. Azm. Tilt -DDW 27 O-3BI —180 90 -Wal— 171 _0.0.57 ---.B.Q 9a Wall 93 0.059 270 _917 Wall 42 0.059 1$0 _90 Wall 45 0.059 270 90 - [door 27 0.387 45 90 /!/all— 65 0.059 0 90 Wall 255 0.059 90 go Wall o _0. 9Q Solar Gains Y/N Form 3 Reference Solid Wood Door R21 wall (W-2t2x616)/&5_/8gyp R-21 Wall (W212x6 161 FlB._gy�/Stu.c�0 R-21 Wall (YV.21.2x6.16) 518gyp/Stucco R--21 Wall (W.21.2x6�615/8ovn!_. f.."A R-21 Wall IW212x6.16) St8gypLStucco )JL80Ptstucco, I)_y/Bgyn/Sher_ Location / Comments Znrle I I I zone III Zone III 7nne III 7nnp III Zone 111 7nne III 7nne III 7onp III Zone 111 1 EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Pane: 12 of 24 1 Computer Method Summary (Part 2 of 3) C -2R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Tvpe Area Factor SHGC Azm. Tilt Comments y Skylight Left _OAtest) 0_6 0.650 0.40 270 -22 Solatube 10" Zone 1 2 Window Right (Southeast) 54.0 0.350 0.34 135 90 SP Clad LoE2,IG/NR/LE Res Zone I 3 Window Right (East) 12.5 0.350 0.34 90 90 SP Clad LoE2.IG/NR/LE Res Zone 1 4 Window Rear (North) 12.0 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone 1 5 Window Rear (North) 42.0 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone I 5 Window Rear (North) 27.0 0.390 0.26 0 90 $P Clad LoE2.IG/NR/LE_ es Zone 1 Z Window Right (East) 42.0 0.350 0.34 go gQ SP Clad LoE2 IG/NR/LE Re- Zone 1 8 Window Front (South) 28.0 0.350 0.34 180 90 SP Clad LoE2,IG/NR/LE_Res Zone 1 -9-- Window Front (South) 28.0 0:350 0.34 180 g4 $P Clad LoE2.IG/NR/LE-Res Zone I 1Q Window Left (West) 10.0 0.350 0.34 270 90 SP Clad LoE2 IG/NR/LE-Res_ Zone I 11 Window Left (West) 10.0 0.360 0.29 270 90 $P Clad LoE2.IG/NR/LE_ es Zone 1 12 Window Left (West) 10.0 0.350 0.34 270 90 SP Clad LoE2.IG/NR/LE Res Zone I 13 Window Left est). 16.0 0480 0.40 270 _90 Weck Glass Block 6x6x4 Zone 1 14 Window Left (West) 12.0 0.360 0.29 270 90 SP Clad LoE2.IG/NR/LE Res Zone 1 15 Window Left (West) 36.0 0.360 0.29 270 90 SP Clad LoE2.IG/NR/LE Res Zone 1 16 Window Left (West) 49.5 0.350 0.34 270 90 SP Clad LoE2.IG/NR/LE Res Zone 1 17 Window Left (West) 16.5 0.350 0.34 270 90 SP Clad LoE2.IG/NR/LE Res Zone I 18 Window Front (South) 4.0 0.360 0.29 180 90 SP Clad LoE2.IG/NR/LE Res Zone 1 18 Window Front (,South) 7.0 0.350 0.34 180 90 SP Clad LoE2.IG/NR/LE Res Zone 1 20 Window Left (West) 5.0 0.350 0.34 270 90 SP Clad LoE2.IG/NR/LE_Res Zone I 21 Window Left (West) 5.0 0.350 0.34 270 90 SP Clad LoE2,IG/NR/LE_Res Zone 1 2 Window Left (Weso 12.0 0.360 0.29 270 90 $P Clad LoE2.IG/NR/LE Res Zone 1 23 Window Left (West) 21.0 0.360 0.30 270 90 SP Clad LoE2,IG/NR/LE_Res Zone I 24 Window Left (West) 21.0 0.360 0.30 270 90 SP Clad LoE2.IG/NR/LE Res Zone 1 25 Window Rear (North) 25.0 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone 1 26 Window Rear (North) 60.0 0.390 0.26 0 90 SP Clad LoE2,IG/NR/LE Res Zone I 27 Window Rear (North) 31.3 0.350 0.34 0 90 SP Clad LoE2,IG/NR/LE_Res Zone I 28 Window Rear (North) 25.0 0.350 0.34 0 90 SP Clad LoE2,IG/NR/LE_Res Zone 1 29 Window Right (East) 38.5 0.350 0.34 90 90 SP Clad LoE2,IG/NR/LE_Res Zone I INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 Bug Screen 0.76 9.0 6.0 2.0 2.5 2.0 2.0 3 Bug Screen 0.76 5.0 2.5 2.0 2.5 2.0 2.0 4 Bug Screen 0.76 5 Bug Screen 0.76 7.0 6.0 4.0 2.5 4.0 4.0 6 Bug Screen 0.76 9.0 3.0 4.0 2.5 4.0 4.0 7 Bug Screen 0.76 8 Bug Screen 0.76 7.0 4.0 2.0 2.5 2.0 2.0 9 Bug Screen 0.76 7.0 4.0 2.0 2.5 2.0 2.0 10 Buq Screen 0.76 5.0 2.0 2.0 2.5 2.0 2.0 11 Bug Screen 0.76 2.0 5.0 2.0 2.5 2.0 2.0 12 Bug Screen 0.76 5.0 2.0 2.0 2.5 2.0 2.0 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 6.0 6.0 2.0 2.5 2.0 2.0 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Buq Screen 0.76 24 bug Screen 0.76 25 Bug Screen0.76 'Bug 26 Screen 0.76 27 Bug Screen 0.76 2.5 12.5 3.5 1.0 3.5 3.5 28 Bug Screen 0.76 29 Bug Screen 0.76 I EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Paae:13 of 24 1 Computer Method Summary (Part 2 of 3) C -2R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 30 Window Right (East) 13.8 0 350 0.34 90 _90. SI? Clad LnF2 IG N / Zone 1 31 Window Right (East) 30.0 0.390 0.26 90 _ges_ 90 SP Clad LoE2.IG/NR/LE Res Zone 1 32 Window Right (East) 7.5 0.350 0.34 90 90 SP Clad LoE2.IG1NR/LE Res Zone 1 33 Skylight Rear (Northeast) 1.8 0.650 0.40 45 22 Solatube 10" Zone II 34 Window Front (South) 27.0 0.350 0.34 180 90 SP Clad LoE2.IG/NR/LE Res Zone II 35 Window Front Louth) 27.0 0.350 0.34 180 90 SP Clad LoE2.IG/NR/LE Res Zone II _W Window Front _ (South) 27.0 0.350 0.34 180 . 90 SP Clad LoE2.IG/NR/LE Res ane 11 37 Window Rear (North) 225.0 0.660 0.33 0 90 PPG SolaBan 60 Brz Me aWood Zone 11 38 Window Rear (Mort) 9.4 0.350 0.34 0 90 §Pcblad LoE2.IG/NR/LERes Zone li M Window Rear (North) 9.4 0.350 6.34 0 90 SP Clad LoUAGMR/LERes Zone II 40 Window Rear (North) 9.4 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone 11 41 Window Rear (North) 9.4 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone II A2 Window Rear (North) 9.4 0.350 0.34 0 _90 SP Clad LoE2,IG/NR/LE Res_ Zone 11 43 Window Rear (North) 9.4 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone 11 44 Window Lett (Northwest) 50.0 0.390 0.26 315 90 SP Clad LoE2,IG/NR/LE Res Zone II 45 Window Left (Northwest) 12.5 0.350 0.34 315 90 SP Clad LoE2.IG/NR/LE Res Zone II 46 Window Rear (North) 10.0 0.350 0.34 0 90 SP Clad LoE2,IGMRILE Res Zone It 47 Window Rear (North) 45.0 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone 11 Ad Window Rear (North) 16.2 0.350 0.34 0 90 SP Clad LoE2.IG/NR/LE Res Zone II 49 Window Rear (Northeast) 10.0 0.350 0.34 45 90 SP Clad LoE2,IG/NR/LE_Res Zone II 50 Window Rear (Northeast) 45.0 0.350 0.34 45 90 SP Clad LoE2,IG/NR/LE_Res Zone 11 Window Rear (Northeast) 16.2 0.350 0.34 45 90 SP Clad LoE2.IG/NR/LE_Res Zone II 52 Window Right (East) 10.0 0.350 0.34 90 90 SP Clad LoE2,IGMR/LE Res Zone II 53 Window Right (East) 45.0 0.350 0.34 90 90 SP Clad LoE2.IGMR/LE Res Zone II 54 Window Right (East) 16.2 0.350 0.34 90 90 SP Clad LoE2,IG/NR/LE Res Zone 11 55 Window Right (Southeast) 50.0 0.390 0.26 135 90 SP Clad LoE2,IG/NR/LE_Res Zone II 56 Window Right (Southeast) 12.5 0.350 0.34 135 90 SP Clad LoE2,IG/NR/LE Res Zone 11 57 Window Left (West) 4.0 0.350 0.34 270 90 SP Clad LoE2,IGMR/LE_Res Zone 111 58 Window Left (West) 14.0 0.350 0.34 270 90 SP Clad LoE2,IG/ R/LE_Res Zone III INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 None 1.00 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 10.0 22.5 16.0 4.5 10.0 10.0 38 Bug Screen 0.76 2.5 3.8 16.0 1.5 10.0 10.0 39 Bug Screen 0.76 2.5 3.8 16.0 1.5 10.0 10.0 40 Bug Screen 0.76 2.5 3.8 16.0 1.5 10.0 10.0 41 Bug Screen 0.76 2.5 3.8 16.0 1.5 10.0 10.0 42 Bug Screen 0.76 2.5 3.8 16.0 1.5 10.0 10.0 43 Bug Screen 0.76 2.5 3.8 16.0 1.5 10.0 10.0 44 Bug Screen 0.76 45 Bug Screen 0.76 2.5 5.0 16.0 1.5 10.0 10.0 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 7.0 2.0 2.0 2.5 2.0 2.0 I EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page: 14 of 24 1 Computer Method Summary (Part 2 of 3) C -2R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Tvpe Area Factor SHGC Azm. Tilt Comments _5,q Window Leff fwjqtl 45, 0.390 n 79 27n _90 SP Glad I oE2,IG/NR/LE Res- 7nne_III 60 Window Left (West) 4.0 0.350 0.34 270 90 SP Clad LoE2,IG/NR/LE Res Zone III 61 Window Left (West) 14.0 0.350 0.34 270 90 SP Clad LoE2.IG/NR/LE Res Zone III 62 Window Rear (North) 25.0 0.360 0.29 0 90 SP Clad LoE2.IG/NR/LE _Res Zone III 63 Window Right (East) 25.0 0.360 0.29 90 90 SP Clad LoE2.IG/NR/LE Res Zone III INTERIOR AND EXTERIOR SHADING Left Fin Right Fin Overhang Window # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 59 Bug Screen 0.76 8.0 5.0 2.0 2.5 2.0 2.0 60 Bug Screen 0.76 61 Bug Screen 0.76 7.0 2.0 2.0 2.5 2.0 2.0 62 Bug Screen 0.76 63 Bug Screen 0.76 5.0 5.0 2.0 2.5 2.0 2.0 I EnergyPro 3.1 By Energysoft User Number. 5021 Job Number. Pane: 15 of 24 1 Computer Method Summary Insulation R -Val. Depth Location / Comments (Part 3 of 3) C -2R Custom Residence for Mr. John Reynolds Slab Perimeter. 6S0_76 12/1/2002 Project Title 0.0 _0 Zone II Slab Perimeter 214 0_76 Date THERMAL MASS FOR HIGH MASS DESIGN 0.0 _0 Zone III etc.) R -Value Type Area Thick. Heat Central Furnace Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Cg.ncrete HeamMeight 1.042 3_50 ---28. 0-98 n/a 2 Zone I I Slab onSradB Concrete. Heavyweight 525 3_50 28 0_98 n/a 0 Zone I / Slab on Grade Concrete. Heave ight 1,065 3_50 28 0.98 n/a 0 Zone II / Slab on Grade Concrete, Heavyweight 214 3_50 28 0_98 n/a 2 Zone 111 .1 Slab on Grade Concrete Hea4 eight 400 3_50 fir} 0_98 n/a 0 Zone III / Slab on Grade PERIMETER LOSSES F2 Type Length Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 143 - 0.76 0.0 _ 0 Zone I Slab Perimeter. 6S0_76 0-0 _Q Zone I Slab Perimeter 06 0_76 0.0 _0 Zone II Slab Perimeter 214 0_76 0-0-0 _Q Zone III Slab PePerimeter 54 0_76 0.0 _0 Zone III HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location ! pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFFUE Ducts in Attic 8.0 Setback HVAC Zone I. Horz Fau-Attic Central Furnace 80%AFUE Ducts in Attic 8.0 Setback HVAC Zone II, Upflw Fau-Gar Central Fumace 80%AFUE Ducts in Attic 8.0 Setback HVAC Zone III. Upflw Fau-Gar Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 15.5 SEER Ducts in Attic 8.0 Setback HVAC Zone I. Horz Fau-Attic Split Air Conditioner 15.5 SEER Ducts in Attic 8.0 Setback HVAC Zone II, Upflw Fau-Gar Split Air Conditioner 15.5 SEER Ducts in Attic 8.0 Setback HVAC Zone 111, Upflw Fau-Gar WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. AMERICAN G62 -75T75 -4N— Large Gas RecirGTime+Temp _ 1 75,100 75 0.79 0.0244 0.0 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 11/23/02 17:42:55 Run Code: 1038102175 Ene Pro 3.1 By EnernySoft User Number. 5021 Job Number. Page: 16 of 24 Computer Method Summary (Addendum) C -2R Custom Residence for Mr. John Reynolds . 12/1/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC Zone I, Horz Fau-Attic " has R-8.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone I, Horz Fau-Attic " has R-8.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone I, Horz Fau-Attic " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Man HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1042 sqft Covered Slab Floor, 3.50" thick at MBRBR#2/Guest BR/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 525 sqft Exposed Slab Floor, 3.50" thick at MBRBR#2/Guest BR/Hall The HVAC System "HVAC Zone It, Upftw Fau-Gar" has R-8.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone ll, Upflw Fau-Gar" has R-8.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone II, Upflw Fau-Gar" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential MASS Design(see C -2R) - Verify Thermal Mass: 1065 sqft Exposed Slab Floor, 3.50" thick at LivinglDininglKitchen The HVAC System "HVAC Zone III, Upflw Fau-Gar" has R-8.0 Heating Dud Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone III, Upflw Fau-Gar' has R-8.0 Cooling Dud Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC Zone III, Upflw Fau-Gar' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential a a HI MASS Design(see C -2R) - Verify Thermal Mass: 214 sqft Covered Slab Floor, 3.50" thick at Den/Laun/Powd/GalleryMall HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "HVAC Zone I, Horz Fau-Attic " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC Zone I, Horz Fau-Attic " is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC Zone 11, Upflw Fau-Gar' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC Zone 11, Upflw Fau-Gar' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC Zone III, Upflw Fau-Gar' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 11123102 17:42:5 Run Code: 10381 175 EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page: 17 of 24 Computer Method Summary (Addendum) C -2R Custom Residence for Mr. John Reynolds 12/1/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the aaequacy or the special justmeation ana documentation submitted. I Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 400 sqft Exposed Slab Floor, 3.50" thick at Den/Laun(Powd/Gallery/Hall HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC Zone III, Upflw Fau-Gar' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:18 of 24 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Custom Residence for Mr. John Reynolds 12/1/2002 SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY R-38 Roof R.38.2x4.24 5/8 Floor /Tile 2 Membrane, Vapor -Permeable Felt 301b 3 Plywood TYPE (check one) Wall 5 Insulation, Mineral Fiber, R-38 p W 7 X Ceiling / Roof 8 2.88 9 N FRAMING MATERIAL Wppd 0.610 41.331 0 Z FRAMING % %o Framing /o 15% (16" o.c. Wall) 10. TOTAL HC 2 9 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 301b 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 5 Gypsum or Plaster Board 7 0.20 8 2.88 9 1.00 2.60 INSIDE SURFACE AIR FILM SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.2101 0.210 0.360 0.360 0.620 0.620 0.800 0.800 38.000 11.385 0.562 0.562 0.20 0.01 2.88 0.35 1.00 2.60 0.6101 0.610 41.331 14.72 Rc R OAC "HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0242 x 0.93 ] 2.50 0.24 0.60 0.52 0.35 0.18 1.42 0.29 0.41 0.031 0.20 0.01 2.88 0.35 1.00 2.60 0.26 0.68 10. TOTAL HC 2 9 "NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0242 x 0.93 ] + [ 0.0679 X L 0.07 1 / Rc 1 - (Fr -/o / 100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page: 19 of 24 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Custom Residence for Mr. John Reynolds 12/1/2002 R -VALUE DESCRIPTION 4MING ASSEMBLY NAME ASSEMBLY R-21 Wall .21.2x6.16 5/8 Floor /Stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 TYPE one) XWall 5 2.63 w(check G UJ 7 Ceiling / Roof 8 9 N FRAMING MATERIAL Wood 0.680 22.65 0° p FRAMING /0 15 o �o � Framing 15% (16" o.c. Wall) 13.8 TOTAL HC 3.4 12% (24" o.c. Wall) 100/6 (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) R -VALUE DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 4 Gypsum or Plaster Board 5 2.63 6 0.98 7 0.26 8 9 INSIDE SURFACE AIR FILM R -VALUE THICK- NESS (in.) 4MING ❑ ❑ © ❑ El 0.170 0.875 0.010 5.500 0.625 21.000 5.445 0.562 0.562 2.63 0.37 R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 21.000 5.445 0.562 0.562 2.63 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 22.65 7.09 KC KT O�C- *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0442 x 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 2.63 0.37 0.98 2.60 0.26 0.68 13.8 TOTAL HC 3.4 *NOTE: Wei ht and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0442 x 0.85 ] X F 0.15 1 / Rc 1 - (Fr-/. / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnerclySoft User Number. 5021 Job Number. PaGe:20 of 24 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Custom Residence for Mr. John Reynolds 12/1/2002 SUBTOTA R -VALUE DESCRIPTION 4MING ASSEMBLY NAME ASSEMBLY R-21 Wall .21.2x6.16 5/8-5/8gyp Floor Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 TYPE (check one) XWall 6 2.63 � W 8 Ceiling / Roof 8 H INSIDE SURFACE AIR FILM FRAMING MATERIAL 0.6801 0.680 23.031 7.48 p Z FRAMING % 15% Framing 7 9 TOTAL HC 2 4 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTA R -VALUE DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 4 5 Gypsum or Plaster Board 6 2.63 7 0.98 8 0.26 8 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) 4MING ❑ ❑ © ❑ El El El El El 0.170 0.625 0.010 5.500 0.625 21.000 5.445 0.562 0.562 2.63 0.37 SUBTOTA R -VALUE CAVITY R VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.562 0.562 0.060 0.060 21.000 5.445 0.562 0.562 2.63 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 23.031 7.48 Rc Rf "HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) I0.0434 x 0.85 ] 2.60 0.26 0.68 0.06 0.35 0.02 2.63 0.37 0.98 2.60 0.26 0.68 7 9 TOTAL HC 2 4 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. I0.0434 x 0.85 ] + [ 0.1337 X 0.15 ] 1 / Rc 1 - (Fr-/. 1100) 11 Rf Fr% 1100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:21 of 24 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Custom Residence for Mr. John Reynolds 12/1/2002 SYSTEM NAME FLOOR AREA HVAC Zone I Horz Fau-Attic 1,567 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 51.1 Cooling System Output per System 49,000 Total Output (Btuh) 49,000 Total Output (Tons) 4.1 Total Output (Btuh/sgft) 31.3 Total Output (sgft/Ton) 383.8 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfmisgft) 1.02 Airflow (cfm/Ton) 391.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 69.2 of Outside Air 0 cfm Supply Fan 1600 ctn, 69.2 of 11.0/77.60F Outside I Air 0 cfm 75.0/60.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,499 32,530 93 1 569 27,462 0 1,627 1,373 0 0 0 0 0 0 0 0 0 1,627 1,373 35,783T7 93 30.209 York H4TS048/P1D1.11316VO80VSPD 37,976 2,632 80,000 Total Adjusted System Output 37,976 2,632 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ,eam TemDeratures at Time of Heatina Peak) 69.2 of n 116.2 of Heating Coil 75.0 / 60.3 of 75.0 / 60.3 of 0 M-4.— A:. n-4, 52.7 / 51.5 of Supply Fan Cooling Coil 1600 drn Supply Air Ducts 115.4 of ROOMS 70.0 of I Supply Air Ducts 53.6 / 51.9 of 44.1% R.H. ROOMS 74.0 / 60.0 of 1 EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:22 of 24 1 C HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Custom Residence for Mr. John Reynolds 12/1/2002 SYSTEM NAME FLOOR AREA HVAC Zone II U flw Fau-Gar 1,065 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 75.1 Cooling System Output per System 49,000 Total Output (Btuh) 49,000 Total Output (Tons) 4.1 Total Output (Btuh/sgft) 46.0 Total Output (sgft/Ton) 260.8 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.50 Airflow (cfm/Ton) 391.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 1,178 26,243 495 432 21,015 0 1,312 1,05 0 0 0 0 0 0 0 0 0 1,312 1,051 28 867 495 23,116 York H4TS048/P1DUB16VO80VSPD 38,254 2,142 80,000 Total Adjusted System Output 38,254 2,142 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.4 OF 69.4 OF 116.40F O Supply Air Ducts Outside Air 0 cfm 115.7 OF Supply Fan Heating Coil 1600 cfm ROOMS 70.0 OF 69.4 OF 11.0/77.6°F 74.8/60.0°F Outside Air 0 0 cfm Supply Fai 1600 dm 74.8/60.0 °F k Return Air Ducts; 74.8 / 60.0 °F M. 52.3 / 51.1 OF Cooling Coil K Return Air Ducts `{ Supply Air Ducts 53.1 / 51.4 OF 43.1% R.H. ROOMS 74.0 / 59.7 OF I EneravPro 3.1 By EnenovSoft User Number. 5021 Job Number. Pane: 23 of 24 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Custom Residence for Mr. John Reynolds 12/1/2002 SYSTEM NAME FLOOR AREA HVAC Zone III, U flw Fau-Gar 614 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 104.2 Cooling System Output per System 24,400 Total Output (Btuh) 24,400 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 39.7 Total Output (sgfUTon) 302.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.30 Airflow (cfmrron) 393.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 45 9,078 286 225 17,544 0 454 877 0 0 0 0 0 0 0 0 0 454 877 9,985 286 19,298 H4TS024/P1DUA12VO64VSPD 17,008 3,470 64,000 Total Adjusted System Output 17,008 3,470 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heating Peak 26.0 of 69.0 of 69.0 of 144.1 of O Supply Air Ducts Outside Air 0 cfm 143.1 OF Supply Fan Heating Coil 800 cfm ROOMS 69.0 of 70.0 of h Return Air Ducts 111.0/77.6OF 74.5/61.1OF Outside Air O 0 cfm Supply Far 800 cfm 74.5/61.1 of ,irstream Temperatures at 74.5/61.10F OF 54.6/53.5OF Cooling Coil h Return Air Ducts `; Supply Air Ducts 55.1 / 53.7 of 47.4% R.H. ROOMS 74.0 / 60.9 of EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number. Page:24 of 24