04-7804 (SFD) Title 24TITLE 24 REPORT CITY OF LA OUINTA- SAFETYBUILDING & SAFETY DEPT. Title 24 Report for: APPF� VED . Andrew Pierce Corporat on FOR CONST CTION Lot 12 -Traditions na s� La Quinta, Ca 92253 - Project Designer: BBG Architects 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 (714) 434-2506 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 Job Number: Date: 1128/05 'The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 I t V TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room. Cooling Peak Loads EnergyPro 3.1 By EnergySoft Job Number: 1 2 3 8 10 17 20 23 28 i User Number: 5533 i Certificate of Compliance: Residential (Part 1 of 2) CF -1 R • Andrew Pierce Corporation , ^ 1/28/05 L' C J Lot 12 -Traditions La Quinta vroject Aaaress H & H Air Conditioning (760) 340-3088 Documentation Author 1 a ep one Computer Performance 15 Building ermit Plan Check / Date -FiTd-C il-ec cf /-date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,582 ft2 Total Conditioned Slab Area: 3,582 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Single Family Attached ❑ Multi -Family Average Ceiling Height: 11.9 ft ❑ Addition ❑ Existing Building ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: X❑ Slab Floor Number of Dwelling Units: 1.00 Number of Stories: BUILDING SHELL INSULATION ❑ Raised Floor Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Slab On Grade Slab On Grade FENESTRATION Wood 0.059 Exterior Wall Na 0.756 Covered Slab w/R-0.0 Perimeter Insulation n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Left (East) 10.0 0.54 0.46 Bug Screen❑ X❑ ❑ ❑X Left (East) 40.0 0.55 0.46 Bug Screen ❑ x❑ ❑ X❑ Left (East) 49.5 0.60 0.46 Bug Screen ❑ X❑ ❑ ❑X Rear (South) 77.5 0.60 0.46 Bug Screen ❑ 0 ❑ XX Right (West) 42.5 0.60 0.46 Bug Screen ❑ N 1 XX Front (North) 36.0 0.60 0.46 Bug Screen ❑ X❑ ❑X❑ Right (West) 12.5 0.57 0.55 Bug Screen XX ❑ ❑ ] Right (West) 40.0 0.55 0.46 Bug Screen ❑ X❑ 0 ❑X Front (North) 24.0 0.54 0.46 Bug Screen X❑ ❑ ❑ a Front (North) 48.0 0.55 0.46 Bug Screen a ❑ ❑ 0 Left (East) 24.0 0.54 0.46 Bug Screen N ❑ ❑ 0 Left (East) 40.0 0.55 0.46 Bug Screen a ❑ ❑ Q Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 33 1 7 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R • Andrew Pierce Corporation ro/ec if e Lot 12 -Traditions La Quinta • 1/28/05 Dae Sul ing ermit H & H Air Conditioning (760) 340-3088 PrateCheck ate Uocumen a ion �t or a ep one Computer Performance 15-Fiela-checK rDa e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,582 ft2 Average Ceiling Height: 11.9 ft Total Conditioned Slab Area: 3,582 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING SHELL INSULATION Component Type FENESTRATION Floor Construction Type: FRI Slab Floor ❑ Raised Floor Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Rear (South) 215.0 0.55 0.46 Bug Screen ❑x ❑ ❑ X Rear (South) 43.8 0.54 0.46 Bug Screen 0 ❑ ❑x❑ Rear (South) 60.0 0.54 0.46 Bug Screen ❑X❑ ❑ ❑x Right (West) 85.0 0.54 0.46 Bug Screen ❑ 0 ❑ 0 Front (North) 36.0 0.54 0.46 Bug Screen ❑ X❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El 11 El F1 11 ❑❑ El El ❑❑ Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 33 • This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: BBG Architects Address: 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 Telephone: (714) 434-2506 Lic. #: D (signature(date) Enforcement ency Name: Title/Firm: Address: Telephone: Name: Title/Firm Address: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 Telephone: (760) 340-3088 (signature) (date) signature/stamp) (date) Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 33 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Andrew Pierce Corporation 1/28/05 Pro/ecfTi e Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN CG32-100T88- Large Gas 1 88,000 96 0.82 0.0239 0.0 41466 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS • This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: BBG Architects Address: 20371 Irvine Ave., Suite 120 Santa Ana Heights, Ca 92707-5651 Telephone: (714) 434-2506 Lic. #: D (signature(date) Enforcement ency Name: Title/Firm: Address: Telephone: Name: Title/Firm Address: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 Telephone: (760) 340-3088 (signature) (date) signature/stamp) (date) Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 33 Certificate of Compliance: Residential (Addendum) CF -1 R rew Pierce Corporation 1/28/05 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. plan The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 630 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 270 sqft Exposed Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 251 sqft Covered Slab Floor, 3.50" thick at Office HIGH MASS Design(see C -2R) - Verify Thermal Mass: 70 sqft Exposed Slab Floor, 3.50" thick at Office HIGH MASS Design(see C -2R) - Verify Thermal Mass: 318 sqft Covered Slab Floor, 3.50" thick at Bedroom 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 66 sqft Exposed Slab Floor, 3.50" thick at Bedroom 2 The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 105 sqft Covered Slab Floor, 3.50" thick at Living/Dining/Kitchen/Noo HIGH MASS Design(see C-211) - Verify Thermal Mass: 1490 sqft Exposed Slab Floor, 3.50" thick at Living/Dining/Kitchen/Nook The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS 4 4 provruer. i ne ncma rater must uocumern ene nein venncduon anu oiaynobuc tebuny ur urebe meabureb vii a aurin �,r-or%. kFee HVAC -Sys em 'HPAC=T" includes—Refr-igerant-C arh ge and Air�flow Cre i or a } Ami i -e- RERS ra er must proviffie verifification of the TXV, or measure the Refrigerant Charge and Airflow. plan Fiel The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run InitiationTime: 5 un Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 33 Certificate of Compliance: Residential (Addendum) CF -1 R -ndrew Pierce Corporation 1/28/05 Wroject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies jabuu um the aucquacy ul Lim bpvwai Jubumcauum amu uucuMrmiauum buumnucu. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) - Verify Thermal Mass: 327 sqft Covered Slab Floor, 3.50" thick at Casita HIGH MASS Design(see C -2R) - Verify Thermal Mass: 55 sqft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. an ie un InitiationTime: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 31 By EnergySoft User Number: 5533 Job Number: Page:7 of 33 • 0 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ED' § 150(d): Minimum R-13 raised Floor insulation in framed floors or equivalent. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no ❑§ greater than 2.0 perm/inch. fYl § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. I ®� §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. El§ 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ® §1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 33 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk 40(*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER JENFORCEI Space Conditioning, Water Heating and Plumbing System Measures: (continued) (X] '§150(m): Ducts and Fans ��, 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other I than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building I cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be I I compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5, Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. i 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable j for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. [X] § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 1 3. Pool system has directional inlets and a circulation pump time switch. i ---___ .------------.---____ ---___ ------- i---- - 4 i[X §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) _ 7-- U§118 (f): Cool Roof material meet specified criteria I Lighting Measures i a§150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. JX] i §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. J LENT I 3.1 By EnergySoft User Number: 5533 Job Number: Page:9 of 33 Computer Method Summary 900 (Part 1 of 3) C -2R Aftndrew Pierce Corporation 20 1/28/05 olect Tit a 0.059 -Date Lot 12 -Traditions La Quinta Wall ' -Project Address 90 Building Permit #—" ----- " H & H Air Conditioning 208 (760) 340-3088 - -Documentation Author 90 I elephone Plan Check/Date Computer Performance 0.059 15 Field-Check/Date-- - -" -Compliance Method -(Package or Computer) Roof Climate Zone -- -- - i Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.48 4.35 0.13 Space Cooling 39.85 37.95 1.90 Domestic Hot Water 7.96 7.73 0.23 _ Totals 51.29_ -50.03 2.216— Wall BUILDING COMPLIES 0 AL INFORMATION Wall [XI Slab Floor Conditioned Floor Area: 3,582 90 Floor Construction Type: F-] Raised Floor Building Type: Single Fam Detached 208 Building Front Orientation: (North) 0 deg 270 Total Fenestration Area: 24.7% Number of Dwelling Units: 1.00 1,595 Total Conditioned Volume: 42,646 Number of Stories: 1 20 Slab Floor Area: 3,582 BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type HVAC -1 _ _ 1,605 _ 16,050 0.45 Sleeping—_ _SleepingStat qrVAC -2 _ _ __ 1,595 22,490 0.45 Living_-_ _ LivingStat . VAC-3 —_ — _ 382 _ 4,106 —0_11 Sleeping_ SleepingStat- --- — --- ---Solar -- — ----- ---- — OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Roof 900 0.028 0 20 Wall — 20 0.059 0 90 Wall 103 0.059 90 90 Wall 208 0.059 180 90 Wall 340 0.059 270 90 Roof 321 0.028 0 20 Wall 160 0.059 0 90 Wall 142 0.059 90 90 Roof 384 0.028 0 20 Wall 125 0.059 0 90 Wall 260 0.059 90 90 Wall 208 0.059 270 90 Roof 1,595 0.028 0 20 Wall 413 0.059 0 90 Wall 631 0.059 90 90 Wall 297 0.059 180 90 Wall 125 0.059 270 _ 90 Roof 382 0.028 0 20 Wall 176 0.059 0 90 Wall 192 0.059 90 90 Wall 180 0.059 180 90 Wall 196 0.059 270 90 R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 WallW( 21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2 -x6.16) R_-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) _ R-21 Wall (W.21.2x6.16) Vent Hgt. Area - 2 n/a 2 n/a _ 2 n/a Location / Comments Master Suite Master Suite Master Suite____ Master Suite _ Master Suite Office Office Bedroom 2 Bedroom 2 Bedroom 2 _ Bedroom 2 Living/Dining/Kitchen Living/Dining/Kitchen living/Dining/Kitchen Living/Dining/Kitchen„ Living/Dining/Kitchen_ Casita Casita --------�-- -. . Casita _Casita — _ — Casita Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 I EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 33 I Computer Method Summary (Part 2 of 3) C -2R ndrew Pierce Corporation 1/28/05 oject Title --- "`- ---- --- - -Dale �-'---" --- - U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Left East) 10.0 0.540 0.46 90 90 Double NonMtl Tinted -- Master Suite 2 Window Left (East) 40.0 0.550 0.46 90 90 Double NonMtl Tinted Master Suite 3 Window Left (East) 6.0 0.600 0.46 90 90 Double NonMtl Tinted Master Suite 4 Window Left (East) 6.0 0.600 0.46 90 90 Double NonMtl Tinted Master Suite 5 Window Rear (South) 45.0 0.600 0.46 180 90 Double NonMtl Tinted Master Suite - 6 Window Rear (South) 32.5 0.600 0.46 180 90 Double NonMtl Tinted Master Suite 7 Window Right (West) 20.0 0.600 0.46 270 90 Double NonMtl Tinted Master Suite 8 Window Left (East) 37.5 0.600 0.46 90 90 Double NonMtl Tinted Office 9 Window Front (North) 10.0 0.600 0.46 0 90 Double NonMtl Tinted Bedroom 2 10 Window Front (North) 10.0 0.600 0.46 0 90 Double NonMtl Tinted ,- Bedroom 2 11 Window Right (West) 12.5 0.570 0.55 270 90 Double NonMtl Tinted Default Bedroom 2 12 Window Right (West) 40.0 0.550 0.46 270 90 Double NonMtl Tinted Bedroom 2 13 Window Front(North) Y. 0.540 0.46 0 90 Double NonMtl Tinted Living/Dining/Kitchen 14 Window Front (North) 28.0 0.550 0.46 0 90 Double NonMtl Tinted Living/Dining/Kitchen 15 Window Front (North) 12.0 0.540 0.46 0 90 Double NonMtl Tinted Living/Dining/Kitchen- 16 Window Front (North) 8.0 0.600 0.46 0 90 Double NonMtl Tinted Living/Dining/Kitchen 17 Window Front (North) 20.0 0.550 0.46 0 90 Double NonMtl Tinted Living/Dining/Kitchen- -i-8 18 Window Left (East) 12.0 0.540 0.46 90 90 Double NonMtl Tinted Living/Dining/Kitchen 19 Window Left (East) 40.0 0.550 0.46 90 90 Double NonMtl Tinted -- Living/Dining/Kitchen 20 Window Left (East) 12.0 0.540 - 0.46 90 90 Double NonMtl Tinted Living/Dining/Kitchen 21 Window Rear (South) 175.0 0.550 0.46 180 90 Double NonMtl Tinted - Living%Dining/Kitchen 22 Window Rear (South) 43.8 0.540 0.46 180 90 Double NonMtl Tinted Living/Dining/Kitchen 23 Window Rear (South) 60.0 0.540 0.46 180 90 Double NonMtl Tinted Living/Dining/Kitchen 24 Window Right (West) 60.0 0.540 0.46 270 90 Double NonMtl Tinted Living/Dining/Kitchen 25 Window Right (West) 11.2 0.600 0.46 270 90 Double NonMtl Tinted Living/Dining/Kitchen 26 Window Right (West) 11.2 0.600 0.46 270 90 Double NonMtl Tinted Living/Dining%Kitchen 0Window 7 Right-` est) 1.2-5" -07540- 0746- -270- -90 Double NonMtTTinted -Living/Dining/Kitchen`" 8 Window Fronf`(North-) 12. -0-540 0.46 0 90- Dou -Ie NonMt1Ti-nfed Casi a 29 Window Front (North) 12.0 0.540 0.46 0 90 Double NonMtl Tinted Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC -Hgt. wa-. en.gtt.. 1-xt. RExt. -Dist.-Len. Hg7. -Dist. Len: - HgE 1 -Bug Screen 0.76 - 2 Bug Screen 0.76 --_- 3 Bug Screen 0.76 4 Bug Screen 0.76 _ 5 Bug Screen 0.76 6 Bug Screen 0.76 -- - - -._ 7 Bug Screen ---- 0.76- -8 Bug Screen - - -0:7*6 - - - --- - - 9 Bug Screen - -- --0.76- 0.76Bug Bug Screen 0.7-6 11 Bug Screen -- --0.76- 5.0 2.5 90.0 -- - - 0.1 10.0 10.0 11 Bug Screen---" ---"- -0.76- ---- - - ---- - -- -- ------ -- YS 13 Bug Screen 0.76 8.0 1.5 4.0 0.1 4.0 4.0 14 Bug Screen 0.76 8.0 3.5 4.0 0.1 4.0 4.0 p 15 -6u-g Screen 0:76- 8-.0 1-5 4.'0 0:1 4-0 4-0 1fi BugScreen -0:76- 17 Bug Screen 0.76 8.0 2.5 0.0 0.0 0.0 0.0 1"8 BugScreen -T. 7'6- -8-0 1.5 16-0 -071 10-0 10-0 --- - 19 Bug Screen 0.76- 8-0 5:0 10-0 0:1 --1 co 10-0 -- - 20 Bug Screen 0-7fi 0-0 1.5 10-0 0.1 10.-6 -f0-0 21 Bug Screen 0.76 10.0 17.5 10.0 0.1 10.0 10.0 22 Bug Screen 0.76 2.5 17.5 10.0 0.1 10.0 10.0 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 - 26 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 _ �- - 29 Bug Screen _0.76 --- --- - Run Initiation Time: 01/28/05 07:45:32 -Run Code: 1106927132 I - EnergyPro 3.1 By EneigySoft User Number: 5533 Job Number: Page: 11 of 33 Computer Method Summary (Part 2 of 3) C -2R ndrew Pierce Corporation 1/28/05 olect Tiftle mate U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 30 Window Front (North) 12.0 0.540 0.46 0 90 Double NonMtl Tinted Casita 31 Window Front (North) 8.0 0.600 0.46 0 90 Double NonMtl Tinted �Y T Casita 32 Window Rear (South) 40.0 0.550 0.46 180 90 Double NonMtl Tinted _ Casita 33 Window Right (West) 12.5 0.540 0.46 270 90 Double NonMtl Tinted _ Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC -Hgt. Wa- -Len. Hgt: LExt—RExt. -Dist. Len. Hgf. -Dist. Len. Hgl. -10-15—ug Screen :76 'T76 -- Ti - 31 Bug Screen 0.76 v 32 Bug Screen 0.76 8.0 5.0 0.0 0.0 0.0 0.0 33 Bug Screen 0.76 — Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page:12 of 33 Computer Method Summary (Part 3 of 3) C -2R ndrew Pierce Corporation Location / Comments Slab Perimeter 1_/28/05 roject Title 0.0 0 Master Suite -Date - - - - - THERMAL MASS FOR HIGH MASS DESIGN 0.76 0.0 Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 630 3.50 28 0.98 n/a 2 Master Suite / Slab on Grade Concrete, Heavyweight 270 3.50 28 0.98 n/a 0 Master Suite / Slab on Grade__ Concrete, Heavyweight_ 251 3.50 28 0.98 n/a 2 Office / Slab on Grade u Concrete, Heavyweight 70 3.50 _ 28 n/a 0 Office / Slab on Grade Concrete, Heavyweight _ 318 3.50 _ _0.98 28 0.98 nla 2 Bedroom 2 / Slab on Grade PERIMETER LOSSES Type Length F2 Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 48 0.76 0.0 0 Master Suite Slab Perimeter 38 0.76 0.0 0 Master Suite Slab Perimeter 29 0.76 0.0 0 Office Slab Perimeter 5 0.76 0.0 0 _ Office Slab Perimeter 49 0.76 0.0 0 Bedroom 2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80%AFUE Ducts In Attic 4.2 Setback HVAC -2 _ Central Furnace 809/6AFUE Ducts in Attic 4.2 _ Setback HVAC -3 Alai Y Piping Pipe Pipe Insul. System Name Length Diameter Thick. Minimum Duct Cooling Equipment Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback _ HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 -` WATER HEATING SYSTEMS Water Heater System Name AMERICAN CG32-100T884N** Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Distribution # in Input Cap. or Recovery Standby R -Value Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Large Gas 1 88,000 96 0.82 0.0239 0.0 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 01/28_/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 - Job Number: Page: 13 of 33 Computer Method Summary (Part 3 of 3) C -2R � ndrew Pierce Corporation 1/28/05______. ro/ect Title -Date THERMAL MASS FOR HIGH MASS DESIGN Distribution Type and Location etc.) F2 Insulation FyOronic Piping Area Thick. Heat R -Val. Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 66 3.50 28 0.98 n/a 0 Bedroom 2 / Slab on Grade Concrete, Heavyweight 105320 0 28 0.98 n/a 2 Living/Dining/Kitchen / Slab on Grade Concrete, Heavyweight 1,490 3.50 28 0.98 n/a 0 Living/Dining/Kitchen / Slab on Grade Concrete, Heavyweight 327 3.50 28 0.98 n/a 2 Casita / Slab on Grade Concrete, Heavyweight 55 3.50 28 0.98 n/a 0 _ Casita / Slab on Grade PERIMETER LOSSES HVAC SYSTEMS Heating Equipment Minimum Type (furnace, heat Efficiency pump, etc.) (AFUE/HSPF)(ducts/attic, Distribution Type and Location etc.) F2 Insulation FyOronic Piping Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 18 0.76— 0.0 0 Bedroom 2 ----'-- Slab Perimeter 61 0.76 0.0 0 Living/Dining/Kitchen Slab Perimeter 83 0.76 0.0 0 Living/Dining/Kitchen Stab Perimeter 62 0.76 0.0 0 Casita Slab Perimeter 17 0.76 0.0 0 Casita HVAC SYSTEMS Heating Equipment Minimum Type (furnace, heat Efficiency pump, etc.) (AFUE/HSPF)(ducts/attic, Distribution Type and Location etc.) Duct Thermostat R -Value Type Location / Comments FyOronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 01/28/05 07:45:32 Run Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: 1 Page:14 of 33 Computer Method Summary (Addendum) C -2R drew Pierce Corporation 1/28/05 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I PlanField The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) - Verify Thermal Mass: 630 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C-211) - Verify Thermal Mass: 270 sqft Exposed Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 251 sqft Covered Slab Floor, 3.50" thick at Office HIGH MASS Design(see C -2R) - Verify Thermal Mass: 70 sqft Exposed Slab Floor, 3.50" thick at Office HIGH MASS Design(see C-211) - Verify Thermal Mass: 318 sqft Covered Slab Floor, 3.50" thick at Bedroom 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 66 sqft Exposed Slab Floor, 3.50" thick at Bedroom 2 The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C•2R) - Verify Thermal Mass: 105 sqft Covered Slab Floor, 3.50" thick at Living/Dining/Kitchen/Nool. HIGH MASS Design(see C-211) - Verify Thermal Mass: 1490 sqft Exposed Slab Floor, 3.50" thick at Living/Dining/Kitchen/Nook The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS 4 • provider. i ne HERS rater must document the nehd venncaton and dhagnosuc resuny oh these measures on a roan Gr-orc. tTeH1T - -System "HVAC-l'ncludes RefrigerantChargeandAirflow Cre r ora ). A ce inJed HERS ra er mut stprovi verifification of the TXV, or measure the Refrigerant Charge and Airflow. Plan ielti The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run InitiationTime: 01128/05 un Code:11069271-32 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 15 of 33 Computer Method Summary (Addendum) C -2R drew Pierce 1/28/05 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies uaacu un u1c auayuduy ui tilt: aNaciai juaulwaiwn aiiu uucumaniauun L UWII1111Cu. Plan I Field The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 327 sgft Covered Slab Floor, 3.50" thick at Casita HIGH MASS Design(see C -2R) - Verify Thermal Mass: 55 sgft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Run InitiationTime: 8 un Code: 1106927132 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 16 of 33 -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY f-y-STEM ROJECT NAME DAT --Andrew Pierce Corporation 1/28/05 NAME FLOOAREA j HVAC -1 1,605 Number of Systems 1,I) Heating System I�( Output per System --- 89,000 Total Output (Btuh) 89,00011 Output (Btuh/sqft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfmisgft) Airflow (cfm/Ton) —' Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 58,000 58,000 4.8 36.1 332.1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG_. PEAK CFM ISensiblel LatentCFM I Sensible , 490i 21,274; 21,049 0 1.0 1,064 -23,401 2,000 . ! 2,000 CARRIER 38HDC060 41,993 6,635 89,000 1.25I� -- -- -- -------- — f - i f 413.8 _ �o.o Total Adjusted System Output 41,993 6,635 89,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 aml INU SYS I tM NSYUNKUMt I KIt:J (Airstream I empe 26.0 of 69.5 of 69.5 of n 111.30F - I - -'� Outside Air 0 cfm Supply Fan Heating Coil 2000 cfm 69.5 of res Supply Air Ducts Is 110.8 of R_OO M_ S 70.0 of Return Air Ducts E I 11.0 / 77.6 of 74.4161.101' 74,4/61,10F ® 54.7/53.6F Outside Air 0 cfm Supply Fan 2000 cfm 74-4/61.1 of Cooling Coil k Return Air Ducts Y Supply Air Ducts 55.2 / 53.8 of 47.3/o R.H. ` ROOMS 74.0 ! 60.9 of EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 117 of 33 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ROJ C NAME -- --------------------- ------ --- DATE---------�-- Andrew Pierce Corporation 1/28/05 1 YSTEM NAME FLOOR AREA HVAC -2 1,595 11.0 / 77.6 of Outside Ai 0 cfm 74.6/61.1 °F EnergyPro 3.1 By EnergySoft COIL CFM Total Room Loads 1,189 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible PEAK Latent ' COIL HTG. PEAK I----- CFM Sensible 23,599 0 571 24,691 0 1,235 01 0 01 o o! 1,235; ; 27,1601 1,180 0 0 0 1,180 25,959 89,0001 Total Adjusted System Output 42,047 6,637 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2pm Jan 12 am, Supply Air Ducts 110.7 of ROOMS — 70.0 of 74.6/61.1OF 74.6/61.1OF 54.8/53.7OF 1 � Sunni Air Ducts f Supply Fan Cooling Coil 2000 cfm User Number: 5533 Y 55.4153.9 of 47.4% R. H. ROOMS.; 74.0 60.9 of . Return Air Ducts Job Number: Page: 18 of 33 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ROJECT NAME DATE Andrew Pierce Corporation 1/28/05 YSTEM NAME FLOOR AREA HVAC -3 382 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK 1COILHTG. PEAK ( CFM Sensible Latent_ "CFM Sensible ' Heating System Output per System 35,000- I, Total Room Loads 239 5,588 ^ 0i r 193 8,257; Total Output(Btuh) 35,000;,, Return Vented Lighting o Output (Btuh/sgft) 91.6j Return Air Ducts 279 4131 , Return Fan o 0i Cooling System ; Ventilation 0 0 0 0 01 Supply Fan 0 j 0: Supply Air Ducts 279 i 413. , TOTAL SYSTEM LOAD 6,147 0 9,083 Output per System 23,600 Total Output (Btuh) I 23,600 Total Output (Tons) 2.0 Total Output (Btuhlsgft) 61.8 Total Output (sgft/Ton) 194.2 Air System HVAC EQUIPMENT SELECTION CFM per System 800 CARRIER 38HDCO2433 19,284 0 r 35,0001 Airflow (cfm) 800 Total Adjusted System Output 1 (Adjusted for Peak Design Conditions) 19,284-- Ol �35,000 Airflow (cfm/sgft) 2.09 Airflow (cfm/Ton) 406.81 outside Air % — �- ( ) Outside Air (cfm/sgft) ioo�100 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions (Airstream I empera ures at Time of Heating ea 26.0 OF 69.5 OF 69.5 OF 110.6 OF > Supply Air Ducts Outside Air • 0 cfm 110.1°F Supply Fan Heating Coil 800 cfm ROOMS 70.0 OF 69.5 OF Return Air Ducts (Airstream Temperatures at Time of Cooling ea 111.0/77.60F 74.3 / 59.4 OF 74.3 / 59.4 OF 51.7 / 50.5 OF Supply Air Ducts r • O Outside Air 0 cfm Supply Fan Cooling Coil 52.0 50.6 OF 800 cfm 41.7% R.H. L 74.3 / 59.4 °F --ROOMS 74.0 / 59.3 OF ' Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:19 of 33� ROOM LOAD SUMMARY ISYESTEM ME DATE Andrew Pierce Corporation 1/28/05 ME FLOOR AREA HVAC -1 1,605 ROOM LOAD SUMMARY --I PAGE TOTAL TOTAL ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite aM a Sup e 1 531 10,633 0 531 10,633 0 248 10,779 Office —office 1 168 3,371 0 168 3,371 0 85 3,687 Bedroom 2 8 -e -room 1 2561 5,132 0 256 5,132 0 157 6,808 PAGE TOTAL TOTAL 1 955 19,136 01490 21,274 955 19,136 011 490 21,274 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:20 of 33 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:21 of T71 0 OJECT NAME IDATE Andrew Pierce Corporation 1/28/05 SYSTEM NAME HVAC -2 FLOOR AREA 1,595 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living/Dining/Kitchen ming Din�Ki c en o 1 1,189 23,599 0 1,189 23,599 0 571 24,691 PAGE TOTAL 1,189 23,599 0 IE 571 24,691 TOTAL 1,189 23,599 0 li 571 24,691 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:21 of T71 4 ROOM LOAD SUMMARY .mgRROJFCT NAME Andrew Pierce Corporation DATE 1/28/05 SYSTEM NAME HVAC -3 FLOOR AREA 382 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Casi a 1 239 5,588 0 239 5,588 0 193 8,257 PAGE TOTAL 239 5,588 0 193 8,257 TOTAL 1 239 5,588 0 193 8,257 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:22 of 33 ROOM HEATING PEAK LOADS 111(ndrew Pierce Corporation Room Information Room Name Floor Area Indoor Dry Bulb Temperature Conduction uea Mastersuite Time of Peak goo Outdoor Dry Bulb Temperature 70 OF Date____ -- 1/28/05 AT o Jan 11oam 26~F Btu/hr = �.1oy� '- � 1 = J*7, =968 2,891 3,827 = = = = = = = = = = = = --/ = ` = ' — —` = ' =| j= [------� ' = } ----- = = = = = = = = = = = ' = r------ ' `--' Items shown with onasterisk Odenote conduction through nninterior _' y�m'rfao— manother room. �Page Total: 1'»J' /»�|n�b�don: � '=_~� u /�� nx Schedule Aii-s—ens-ib-I-e Area FractionOTAL HOURLY HEAT LOSS FOR ROOM 10,7779 — '— Page:oofo — ROOM HEATING PEAK LOADS oject Title Date ndrew Pierce Corporation 1/28/05 Room Information Design Conditions Room Name office Time of Peak Jan 12 am; Floor Area 321 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF; Conduction Area U -Value AT of Btu/hr Items shown with an asterisk ('f) denote conduction through an interior surface to another room. Infiltration: I 1.00 x 1.064 x 321 x 10.00 x 0.00 160 x Schedule Air Sensible Area eimg Height A Fraction Page Total 44 pT 396) 788, = 990? = 1,5131 = i t ... I TOTAL HOURLY HEAT LOSS FOR ROOM 3,687 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 24 of 33 J ROOM HEATING PEAK LOADS olect Title Date ndrew Pierce Corporation 11/28/05 Room Information Design Conditions Room Name Bedroom 2 Time of Peak Jan 12 am Floor Area 384 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 25 of 33 R-38 Roof (R.38.2x14.16) 384.0 X 0.0280 X 44.0 = 473; R-21 Wall (W.21.2x6.16) 592.5 x 0.0592 x 44.0 = 1,544 Double NonMtl Tinted 20.0 x 0.6000 x 44.0 = 528 Double NonlAtl Tinted Default 12.5 X 0.5700 x 44.0 = 3141 Double NonMtl Tinted 40.0 X 0.5500 X 44.0 = 968 Slab -On -Grade perimeter= 67.0 X X 44.5 = 2,9821 x x = x x = x x = x x = x x = __ x x = i x x = _J x x = x x = x x = x x = • x x = x x x = —�x x x = x x = x x = x x = - x x = — �— x x = x x = x x = x x = x x =I _ x x x x = x x = x x = . x x = x x = x x = x x = Items shown with an asterisk (f) denote conduction through an interior surface to another room. Page Total: [� 0 Infiltration: �1 I x 1.06 x l_ 384 x x �00 16011 x —1_00 _ _10.00 Schedule Air Sensible Area Ceiling Height ACA J pT Fraction qW TOTAL HOURLY HEAT LOSS FOR ROOM 6,808 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 25 of 33 ROOM HEATING PEAK LOADS 'Andrew Pierce Corporation Room Information Design Conditions Room Name Wng/DininglKitchen/Nook Time of Peak Floor Area 1,595 Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 700,1. Conduction Area U -Value r1 U x X x x X X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x — 0.0280 x x x X X X X x X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0592 0.5400 0.5500 0.6000 Items shown with an asterisk ('} denote conduction through an interior surface to another room. Infiltration: [ 1.00 X F1.064 X 1,595 X 14.10 X0.00 / 60� X Schedule Air Sensible Area Ceiling Height AC J Fraction 1/28/05 AT OF Page Total pT Jan 12 am i 26 of Btu/hr 1,965' = ��3,820 5,328 _- 6,365{ 8051 6,4081 = Y 1. = i = i I– 24,691 E_ - it L.—.._-.-....-. _ ..0I TOTAL HOURLY HEAT LOSS FOR ROOM 24,691 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 26 of 33 ROOM HEATING PEAK LOADS !Kndrew Pierce Corporation 11/28/05 Croom Information Design Conditions Room Name Casita Time of Peak Jan 12 am' Floor Area 382 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area 382.0 744.5 48.5 8.0 40.0 perimeter = 79.0 U -Value AT OF 44.0 44.0 44.0 44.0 44.0 44.5 Items shown with an asterisk (I"�) denote conduction through an interior surface to another room. Page Total: Infiltration: I_ 1_00 x 1.064 x 382 x 10_75 x 0.00 16071 x Schedule Air Sensible Area Ceiling Height ACH J pT Fraction Btu/hr = 471 = 1,940 = 1,152 _96_81 3,5161 _tel L-- 2 ----- — 0I TOTAL HOURLY HEAT LOSS FOR ROOM 8,257 EnergyPro 3.1 By EnergySoft User Number: 5533 _ Job Number: — Page: 27 of 33 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation 1/28/05 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: 740E Design Outdoor Dry Bulb Temperature: 112°F Design Temperature Difference: 38OF • Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Area X X X X X X X x X U -Value X X X X X X X X X DETD 1 900.0 0.0280 55.0 670.5 0.0592 34.6 10.0 0.5400 38.0 40.0 0.5500 38.0 109.5 0.6000 38.0 73) 0.512 224 0.0 45.0 32) 0.512 737 533 - 748 0.0 32.5 32) 73) 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window x X x x X x x x x X (East) Window x x X X X x x x X x (East) Window 0.512=_ (East) Window 0.0 (East) Window 0.512 (South) Window ( (South) (West) Window 6.0 73) 0.512 Page Total SC Btu/hr 1,386 _1,374 _ 205 _ 8_36 2,4971 6,298 Btu/hr 0.0 x X x x X x x x x X 15+ is ,+ 15 + 15 + 1 + 1 S + 15 + + + + 10.0 x x X X X x x x X x 73)X x X X X X X ) x )X 0.512=_ = = = = = = "374- 7-0.0 1,495' 224 0.0 40.0 73) 0.512 0.0 6.0 73) 0.512 0.0 6.0 73) 0.512 224 0.0 45.0 32) 0.512 737 533 - 748 0.0 32.5 32) 73) 0.512 0.512 0.0 20.0 Sched. Page Total 4,335) Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 900 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Occupants 1.00 x 900 x 255 Btuh/occ. / 0 sqft/occ. = 0 Receptacle 1.00 X 900 X 0.000 Wattslsgft x 3:413 BtuhfWatt = 0 Process. 1.00 x 900 x 0.000 Watts/sgft x 3.413 Btuh[Watt = _0 Infiltration:�LS 1.00 x 1.064 x 900 x �10.00 x 0.00 / 60] 38 = 0) chedule X -Ir Sensible Area ceiling FleigTit ACA Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,633 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants _ _ _ F1100 x -9-0011X 225 Btuh/occ. / S ft/OCC. = _ �J_0 Receptacle 1.00 x 900 x 0.000 Watts/sgft x00 3.413 Btuh/Watt = 0 Process 1.00 x 9 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 x _ 4,771 x _900, x -1000 x o.00 / 60] O.o0000 = 0,, Schedule Air Latent Area Ceiling Heigh ACH nW •Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 28 of 33 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation _ — _ 1/28/05 _ Project Title Date Room Name Office Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 380F 40 Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Area X X X X X X X x X U -Value X X X X X X X X X DETD 1 = = = = = = = Btu/hr 0.0280 55.0 494 0.0592 34.6 620 0.6000 38.0 855 Area SGF SC Btu/hr Window (East) ( 0.0 x1 + 37.5 x 73)x 0.512 = - --- -- - + ( x + x )x = - - 1. Design Equivalent Temperature Difference (DETD) a Pa Total g 9 1,69 � Items shown with an asterisk (') denote conduction through an interior surface to another room. -- - Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (East) ( 0.0 x1 + 37.5 x 73)x 0.512 = 1,40.2 ( x + x )x = ( x + x )x = __ ( x + x )x =N - ( x + x )x = -- ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )X = ( x + x )x = Sched. Page Total _1,402 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 321 X 0.000 Watts/sqft x 3.413 BtuhfWatt = 0i Occupants 1.00 X 321 X 0 Btuh/OCC. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 321 X 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Process 1.00 x 321 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: [ 1_00 x 1.064 x �— 321 x _ 10.00 x 0.00 / 60] 38 = _ 01 Schedule Air Sensible Area Ceiling Height L. pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,371 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 321 x 0 Btuh/occ. / 20,000 sgft/occ. = Receptacle 1.00 x 321 x 0.000 Watts/sqft x 3.413 Btuh/Watt = Process 1.00 x 321 x 0.000 Watts/sqft x 3.413 Btuh[Watt =1-19 Infiltration: L Sch1_00 x - 4,771 x 32 x 10.00 x 0.00 / 60] 0.00000 = F edule Air Latent) Area Ceding HeigKt ACH pW •Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft _- _User Number: 5533 _ _ _Job Number __� - _- _ Page: 29 of 33 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation 1/28/05 Project Title Date Room Name Bedroom 2 • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Default Double NonMtl Tinted I Area 384. 592.5 _ 201 12.51 40.0 U -Value 0. 74° F 112°F 380F x x x x x x x x DETD 1 = = = = = = = = Btu/hr 591 55.0 34.6 1,214 38.0 456 - - -271 836] - 38.0 38.0 10.0x 15)x 0.512 12.5 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window (North) Window (North) Window (West) Window (West) 0.512 0.0x 15+ 10.0x 15)x 0.512 12.5 Page Total 3,368 SC 0.0x x x x x x X X 15+ + + + + + + 10.0x x x x x x x X 15)X x )x )x ) x )X 0.512 0.0x 15+ 10.0x 15)x 0.512 12.5 15+ 0.0 73)x 0.612 0.0 15 40.0 73) 0.512 -- Btu/hr 7 71 77 115 1,495 Sched. Page Total 64] Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 384 X 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Occupants 1.00 x 384 X 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 384 X 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Process 1.00 x 384 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: _ 1_00 x 1.064 x 384 x _ 10.00 x 0.00 / 60] Schedu a Air Sensible Area eiling Heigh Ac p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,132 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants _ 1.00 x i 384�x 0 Btuhlocc. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 384 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 384 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0 Infiltration: [ 1_00 x _ 4,771 x 384 x _10.00 x 0.00 / 60] 0.00000 = ul Schedule Air Latent) Area Ceiling Height ACR ^w •Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 30 of 33 RESIDENTIAL ROOM COOLING LOAD SUMMARY • Andrew Pierce Corporation 1/28/05 Project Title Date Room Name Living/Dining/Kitchen/Nook • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double NonMtl Tinted Double NonMtl Tinted Double NonMtl Tinted Area X X X X X X X x X U -Value X X X X X X X X X DETD 1 5 591 0 0.0280 55.0 1,466.2 0.0592 34.6 224.2 263.0 0.5400 38.0 0.5500 38.0 30.5 0.6000 38.0 (South) 8.0 15)X 0.512= 61 154 0.0 20.0 15)x 0.512= 11.9 0.1 73) 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window (North) Window (North) Window (North) Window (North) Window (North) Window (East) Window (East) Window (East) Window (South) Window (South) Page Total SC 740F 112°F 380F Btu/hr 2,457 3,004 4,602 5,497 695 =,2541 Btu/hr 0.0 X x X15+ X X X1 X x x 15+ 15 + 15+ 15+ 15 + + 1 + 1 + 1 + 12.0 X X X X X X X x x 15)X X X 0.512= = = = = _ = 92 0.0 28.0 15)X 0.512 215 0.0X 0.0 12.0X 15)x 0.512= 92 8.0 15)X 0.512= 61 154 0.0 20.0 15)x 0.512= 11.9 0.1 73) 0.512 97 39.5 0.5 73) 0.512 322 11.9 0.1 73)x 0.512 97 175.0 0.0 32)X 0.512 1,344 43.8 0.0 32)x 0.512 336 Sched. Page Total2,810 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,595 x 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Occupants 1.00 X 1,595 X 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 1,595 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,595 X 0.000 Watts/sqft x 3.413 Btuh/Watt = -0 Infiltration: [ 1.001 x 1.064 x 1,595 x _ 14.10 X 0.00 / 60] 38 SchetlulB Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,599 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,595 X 225 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 x 1,595 x 0.000 Watts/sgft X 3.413 Btuh/Watt = 0 Process 1.00 x 1,595 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 X 4,771 X 1,595 X 14.10 X 0.00 / 60] 0.00000 = �� Schetlule Air Latent) Area Ceilin' g Heigh ACH pW •Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o lEnergyPro 3.1 By EnergySoft User Number: 5533 ___ Job Number: Page: 31 of 33 • . 1 6 • u RESIDENTIAL ROOM COOLING LOAD SUMMARY Andrew Pierce Corporation Proiect Title 1/28/05 Date Room Name Living/Dining/Kitchen/Nook Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETO) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window Window Window Window Window DETD1 Page Total SC 740E 112°F 38°F Btu/hr 1�J Btu/hr (South) ( 0.0 ( 0.0 ( 0.0 (-0.0 ( 0.0 ( ( ( ( ( x x x X X X X x X X 1 + + + + + + + + + t 60.0 x X x X x X x X x X 32)X X )X )X )X )x )X 0.512 = = = = = = =� _ 983 (West) 60.0 73)x 0.512 2,243 (West) —41' 15 11.2 73) 0.512 421 (West) 1 11.2 73)X 0.512 421 (West) 1 12.5 73)x 0.512 467 Sched. Page Total a,53a Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,595 X 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Occupants` 1.00 x 1,595 X 255 Btuh/occ. I 0 sgftlocc. = Receptacle 1.00 X 1,595 X 0.000 Watts/sgft x 3.413 Btuh/Watt = �� 0+ Process 1.00 x 1,595 x 0.000 Watts/sqft x 3.413 Btuh[Watt = I 01 Infiltration: [ _ 1_00 x _ 1.064 x 1,595 x 14.10 x 0.00 / 60] Schedule Air Sensible Area Ceiling eig C p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,599 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants1.00 X 1,595 x 225 Btuh/occ. I Ol sgft/occ. Receptacle 1.00 x 1,595 x _ 0.000 Watts/sgft x 3.413 Btuh/Watt = �! 0 Process 1.00 x 1,595 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1_00 X _ 4,771 X 1,595 x _14.10 X 0.00 / 60] 0.00000 = Schedule Air latent Area Ceiling Height Kc F1 pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 32 of 33 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation Project Title • u Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 1128/05 Casita 740F 112°F 380F Conduction Area U -Value DETW Btu/hr X 382.01 X X X X X X- X x X 744.5 48.5 8.0 40.0 = , 1,525, X (South) (West) 38.0= X (North) 55.0 = 588 X (North) 34.6 = , 1,525, X (South) (West) 38.0= 995' X 0.512= 38.0 = 182 X _ 15)x 15)x 38.0 = 836 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 4,1 z7 Items shown with an asterisk'(*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (North) Window (North) Window (North) Window (North) Window Window (South) (West) 0.0x 12.0x 15)X 0.512= 92 0.0 0.0X-15+ 12.0 _ 15)x 15)x 0.0 X X15+ X X X X X X 1 + 15'+ 15 + 1+ + + + + 12.0 X X x x X X x X 15)x )X )x )X )x 0.512 = = = = = = 92 0.0x 12.0x 15)X 0.512= 92 0.0 0.0X-15+ 12.0 _ 15)x 15)x 0.512= 92 8.0X 0.512= 61 I 655 1467 0.0 40.0 32)x 0.512 0.512 0.0 12.5 73)X Sched. Page Total 1,as1 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 382 X 0.000 Watts/sgft x 3.41 BtuhtWatt = 0 Occupants 1.00 X 382 x 255 Btuh/occ. I 0 sgft/occ. = 0 r~ Receptacle 1.00 x 382 X 0.000 Watts/sgft x 3.413 BtuhlWatt = 0 Process 1.00 x 382 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ _1_00 X _ 1.064 X 382 X _ 10.75 X L- 0.00 / 6�� 38 = �� Schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,588 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants _ 1.00 x 38z x 225 Btuh/occ. I o sgftlocc. _ �0 Receptacle 1.00 x 382 x 0.000 Wattslsgft x 3.413 Btuh/Watt = 0 Process 1.00 x 382 x 0.000 Watts/sgft x. 3.41 Btuh/Watt = 0 Infiltration: [ _ 1_00 x _ 4,771 x 382 x _10075 X 0.00 / 60] QOtON0000 = Schedule Air Latent Area Ceiling Heigfi AC Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number_ Page: 33 of 33 1