05-0099 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: Andrew Pierce Corporation 78-691 Deacon Dr, Lot 19 -Traditions La Quinta, Ca 92253 Project Designer: Michael Kiner Associates, AIA 70-177 Highway 111, Suite 200 Rancho Mirage, Ca 92270 (760) 324-3360 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 Job Number: Date: 5/9/05 CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE - • o---:5- gy ,s T i The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. na This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1R Mandatory Measures Checklist 7 Form C -2R Computer Method Summary 9 'I HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 18 Room Heating Peak Loads 21 Room Cooling Peak.Loads 24 _ .. User Number: 5533 EnergyPro 3.1 _ By EnergySofl Job Number: • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Andrew Pierce Corporation, ^ 5/9/05 78-691 Deacon Dr, Lot 19 -Traditions La Quinta vro/ect Aaaress H & H Air Conditioning (760) 340-3088 Documen a ionu or a ep one Computer Performance 15 Compliance Method (Package or Computer) Climate Zone Building ermrt Plan Check Date Field ec Date tntorcement Agency use umy GENERAL INFORMATION Total Conditioned Floor Area: 3,759 ft2 Average Ceiling Height Total Conditioned Slab Area: 3,759 ft2 Building Type: (check one or more) © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: o Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Solid Wood Door None 0.387 Exterior Door 0.55 0.46 Bug Screen ❑ X❑ ❑ XP Left FENESTRATION 10.3 ft Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Skylight 3.1 0.80 0.46 None P X❑ ❑ PX Left (East) 48.0 0.55 0.46 Bug Screen ❑ X❑ ❑ XP Left (East) 25.0 0.60 0.46 Bug Screen ❑ XP ❑ ❑x Left (East) 78.2 0.54 0.46 Bug Screen P XP P ❑X Rear (South) 52.5 0.54 0.46 Bug Screen XP ❑ ❑ XX Rear (South) 202.0 0.55 0.46 Bug Screen_ 191 ❑ ❑ Px Right (West) 16.0 0.60. 0.46 Bug Screen ❑ Q P ❑x Right (West) 88.0 0.55 0.46 Bug Screen P 0 a a Front (North) 54.0 0.55 0.46 Bug Screen © ❑ ❑ XP Front (North) 88.0 0.55 0.46 Bug Screen P Q ❑ Q Rear (South) 25.0 0.60 0.46 Bug Screen ❑ o P O Rear (South) 57.5 0.54 0.46 Bug Screen ❑ a ❑ 0 Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 28 r1 I� J • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Andrew Pierce Corporation 5/9/05 Project Title Date 78-691 Deacon Dr, Lot 19 -Traditions La Quinta Project Address H & H Air Conditioning (760) 340-3088 Documentation Author I a ep one Computer Performance 15 Compliance Method (Package or Computer) Climate Zone GENERAL INFORMATION Total Conditioned Floor Area: 3,759 ft2 Total Conditioned Slab Area: 3,759 ft2 Building Type: (check one or more) © Single Family Detached ❑ Single Family Attached ❑ Multi -Family Building ermit Plan Check / Date Field Check I Date Enforcement Agency Use Only Average Ceiling Height: 10.3 ft ❑ Addition . ❑ Existing Building ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: FRI Slab Floor Number of Dwelling Units: 1.00 Number of Stories: BUILDING SHELL INSULATION ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Right (West) 59.2 0.54 0.46 Bug Screen ❑ X❑ ❑ X❑ Rear (South) 24.0 0.55 0.46 Bug Screen ❑x❑ ❑ ❑x Right (West) 10.8 0.60 0.53 Bug Screen ❑ x❑ ❑ ❑x ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El El El El ❑ ❑ ❑ ❑ Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 28 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Andrew Pierce Corporation External 5/9/05 Por�ec i e or Recovery Standby Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Efficiency Loss (%) R -Value Heating Equipment Minimum Type and Duct or 0.82 0.0239 Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 0 • Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN CG32-100T88- Large Gas Recirc/Time+Temp 1 88,000 96 0.82 0.0239 0.0 4'N -- I For small gas storage (rated inputs of less than or equal to 75,000 Btulhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Address: Michael Kiner Associates, AIA 70-177 Highway 111, Suite 200 Rancho Mirage, Ca 92270 Telephone: (760) 324-3360 Lic. (siljnatur e) (date) Enforceme t Agency Name: Title/Firm: Address: Telephone: Name: Title/Firm Address: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 P Im Desert, CA 92260-2043 Telephone: ( 0) 340-3P88 --c� siq 10 s - (signature) (date) (signature/stamp) date Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 28 Certificate of Compliance: Residential (Addendum) CF -1 R Aftndrew Pierce Corporation 5/9/05 roject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oasea on ene aaequacy or vie special Jusuncauvn aria aocurireniauon suurnnceu• Plan I Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1135 sqft Covered Slab Floor, 3.50" thick at Master Suite, Bdrms 2 & HIGH MASS Design(see C -2R) - Verify Thermal Mass: 577 sqft Exposed Slab Floor, 3.50" thick at Master Suite, Bdrms 2 & 3 The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 228 sqft Covered Slab Floor, 3.50" thick at Living/Kitchen/Dining HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1349 sqft Exposed Slab Floor, 3.50" thick at Living/Kitchen/Dining The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 366 sqft Covered Slab Floor, 3.50" thick at Guest Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 104 sqft Exposed Slab Floor, 3.50" thick at Guest Suite HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS 4 4 provider. The HERS rater must document the fheld verification and diagnostic testing of these measures on a form CF -6R. an ie ' he RVAC y5 sfem "RPAC=1' includes Refrigerant Charge and Airflow Credit (ora certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The WAC-SySEem 'RVA - is using reduced uc leakage to comply 5-fia must have diagnostic site testing of ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. heWAC yS stem "RVAC7-_3' includes Refrigerant Charge and AirfIo_w_C_re__diF_(6ra certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. he HVAC yS s{em "HVAC; 3' is using reduceaduct leakage to comply and must have diagnostic site testing of ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run InitiationTime: 05/09/05 un Code: 1115657352 EnergyPra 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 28 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an • asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ®*§150(c): not apply to exterior mass walls). ❑ * § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. § 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. fYl § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. L®J §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. a§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® §150(i): Setback thermostat on all applicable heating and/or cooling systems. ® § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:7 of 28 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk • (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. L' • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) LXX '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, t I equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable I for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. [X1 § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. IX -1 1 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) t XJ §118 (f): Cool Roof material meet specified criteria Lighting Measures § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. (� §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement — allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 28 Computer Method Summary . (Part 1 of 3) C -2R ndrew Pierce Corporation 0.028 5/9/05 -Date roject Title Wall _ 207 _ 0.059 78-691 Deacon Dr, Lot 19 -Traditions La Quinta Wall _ _ 36 -Project Address 45 90 Building Permit # H & H Air Conditioning 0.059 (760) 340-3088 90 Documentation Author _ 134 Tetep one Pan Check/Date Computer Performance Wall 15 0.059 Field-ChecFJ ate -Compliance Method (Package or Computer) Climate one 0.028 Source Energy Use Standard Proposed Compliance 350 (kBtu/sf-yr) Design Design Margin _Door__ Space Heating 3.82 3.00 0.82 90 Space Cooling 36.73 34.87 1.86 90 Domestic Hot Water 7.58 8.17 -0.59 0.059 --0.059 _ Totals 48.12 46.04 2.08 _ 53 Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name HVAC -1 KVAC-2 VAC -3 3,759 Single Fam Detached (North) 0 deg 1.00 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume XD Slab Floor Floor Construction Type: F-1 Raised Floor Total Fenestration Area: 22.1 % Total Conditioned Volume: 38,657 Slab Floor Area: 3,759 # of Thermostat Vent Units Zone Type Type Hgt. Area 1,712 16,435 0.46 Conditioned Setback 2 Na 1,577 17,662 0.42 Living LivingStat 2 Na 470 4,559 0.13 Sleeping SleepLg.§ tat 2 Na Solar Gains Y/N Roof ___.1,709 0.028 0 20 Wall _ 207 _ 0.059 0 90 Wall _ _ 36 0.059 45 90 Wall _ _ 443 0.059 90 90 Wall _ _ 134 0.059 180 90 Wall 0.059 270 90 Roof. _119_ 1,577 0.028 0 20 Wall .— 350 0.059 0 90 _Door__ _ V22 0.387 0 90 Wall 132 0.059 90 90 Wall 286 0.059 --0.059 180 90 Wall _ 53 0.059 270 90 Roof _ 470 0.028 0 20 Wall 171 0.059 0 90 Wall 231 0.059 90 90 126 0.059 180 90 Wall 217 0.059 270 90 Energypro 3.1 Form 3 Reference R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof JR.38.2xl4.16) R-21 Wall (W.21.2x6.16) Solid Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) R-21 Wall (V11.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Location / Comments Master Suite, Bdrms 2 & 3 Master Suite, Bdrms 2 & 3 Master Suite, Bdrms 2 & 3 Master Suite, Bdrms 2 & 3 Master Suite, Bdrms 2 & 3 Master Suite, Bdrms 2 & 3 Living/Kitchen/Dining/Ent Living/Kitchen/Dining/Ent Living/Kitchen/Dining/Ent Living/Kitchen/Dining/Ent Living/Kitchen/Dining/Ent Living/Kitchen/Dining/Ent Guest Suite Guest Suite Guest Suite _ Guest Suite Guest Suite Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 By EnergySoft User Number: 5533 Job Number: Page:9 of 28 Computer Method Summary (Part 2 of 3) C -2R drew Pierce Corporation _&ct Title __, # Type Area 1 Skylight Front (North) 3.1 2 Window Left (East) 48.0 3 Window Left (East) 15.0 4 Window Left (East) 37.8 5 Window Left (East) 4.4 6 WindowLeft 180 (East) 6.0 7 Window Left _ (East) _ 6.0 8 Window Rear (South) 12.5 9 Window Rear (South) 20.0 10 Window Rear (South) 40.0 11 Window Rear (South) 20.0 12 Window Right (West) 16.0 13 Window Right West_ 40.0 14 Window Front (North) 54.0 15 Window Front (North) 44.0 16 Window Front (North) 44.0 17 Window Left (East) 24.0 18 Window Rear (South) 162.0 19 Window_ Rear_ (South) 25.0 20 Window Rear (South) 17.5 21 Window Right (West) 48.0 22 Window Right (West) 10.0 23 Window Right (West) 18.0 24 Window 14 (West) 18.0 25 Window _Right_ __Left___ (East) _ 10.0 6 Window _ Rear (South) 20.0 7 Window`-Rear---(South) 18 -24..0- 8 W iffd6 -Rear ` (South) -20-0- 29 Window Right (West) 4.4 INTERIOR AND EXTERIOR SHADING U- Act. Glazing Type Factor SHGC Azm, Tilt 0.800 0.550 0.600 0.540 0.540 0.540 0.540 0.540 0.540 0.550 0.540 0.600 0.550 0.550 0.550 0.550 0.540 0.550 0.600 0.540 0.550 0.540 0.540 0.540 0.600 0.540 -0.-550- -0-54:0- 0.540 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0..46- o.4s 0.46 519105 `Date Location/ Comments 0 20 Double Metal Tinted Default Master Suite Bdrms 2 & 3 90 90 Double NonMtl Tinted Master ZiuIte, Barms 90 90 Double NonMtl Tinted Master Suite, Bdrms 2 & 3 90 90 Double NonMtl Tinted Master Suite, Elarms 90 90 Double NonMtl Tinted Master Suite, Bdrms 2 & 3 90 90 Double NonMtl Tinted Master Suite, Bdrms 2 & 3 90 90 Double NonMtl Tinted Master Suite Bdrms 2 & 3 180 90 Double NonMtl Tinted master Suite, Elarms 180 90 Double NonMtl Tinted Master Suite, Bdrms 2 & 3 180 90 Double NonMtl Tinted Master Suite, Bdrms 2 & 3 180 90 Double NonMtl Tinted Master Suite Bdrms 2 & 3 270 90 Double NonMtl Tinted Master uite,rms 3 270 90 Double NonMtl Tinted Master Suite Bdrms 2 & 3 0 90 Double NonMtl Tinted -Living etc en iningi nt 0 90 Double NonMtl Tinted Living/Kitchen/ inin n 0 90 Double NonMtl Tinted rvin itc en Dinin /Ent 90 90 Double NonMtl Tintedrvin i c en ening n 180 90 Double NonMtl Tinted rving i c en ming n 180 90 Double NonMtl Tinted Living/Kitchen/Dining/Ent 180 90 Double NonMtl Tinted wing c en ening n 270 90 Double NonMtl Tinted Living i c henM in Mng n 270 90 Double NonMti Tinted Living/Kitchen/Dining/Ent 270 90 Double NonMtl Tinted wing i c en ming n 270 90 Double NonMtl Tinted Living/Kitchen/Dining/Ent 90 90 Double NonMtl Tinted Guest buite 180 90 Double NonMtl Tinted Uuest Suite T80F -90 Double NonNftrTinted- Guest Suite T90 -90 Dou6leNonMfl Tinted' Uuest Uuite 270 90 Double NonMtl Tinted Guest suite Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC -MgT-T7cr' Len. Hgt. LEX . x . Uist. en. g . u1st. Len. Trgr --- 2 Bug Screen 0.76 3 _ _ Bug Screen Y _ 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6` Bug Screen 0.76 Bug Screen 0.76 Y- Bug`Screen 0.76- -5.0 -275 -6-0 -01 -60 6-0 T Bug Screen 0.76 8.0 2.5 6.0 0.1 6.0 6.0 10 Bug Screen 0.76 8.0 5.0 6.0 0.1 6.0 6.0 11 964 -S -6 -re -en 0.7fi 8-0 2:5 60 0-1 60 -60 12 Bug Screen 0:76- -- -- 13 Bug Screen 14 Bug Screen 0.76- 9.0 6.0 8.0 0.1 8.0 8.0 T5 Bug Screen - 0;76- 18 Bug Screen -0:76- �- 17 Bug Screen 0.76 1-8 Bug Screen 0:76- -9F0 18.0 -60 0.1 -60 6-0 19 Bug Screen 0.76- -- Bug Screen 0.76 _211 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen _ 0.76 B8 0.7627 _ 02-6ugScreen Bug Screen 0762 Bug Screen 0.76 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 28 Computer Method Summary (Part 2 of 3) C -2R ndrew �Pierce Corporation 5/9/05 ojeci Tifle -- — — -- -^ -Date U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 30 Window Right (West) 4.4 0.540 0.46 270 90 Double NonMtl Tinted Guest Suite 31 Window_ Right (West) 4.4 0.540 0.46 270 90 Double NonMtl Tinted Guest Suite 32 Window Right (West) 10.8 0.600 0.53 270 90 Double NonMtl Tinted Default Guest Suite — INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin #Exterior Shade Type SHGC -Hgt. Wd- en. gt. -Ext: RExt. -Dist.—Len. Rg is . H -Dt. Lengt. _ -SO- Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 28 Computer Method. Summary (Part 3 of 3) C -2R ndrew Pierce Corporation 5/9/05 oject Tille -Date THERMAL MASS FOR HIGH MASS DESIGN F2 Area Thick. Heat Type (sq (in.) Cap. Concrete, Heavyweight 1,135 3.50 28 Concrete, Heavyweight 577 3.50 28 Concrete, Heavyweight 228 3.50 28 Concrete, Heavyweight 1,349 3.50 28 Concrete,. Heavyweight _ - 366 3.50 28 PERIMETER LOSSES Cond. Form 3 Reference 0_98 n/a 0_98 n/a 0_98 n/a 0_98 n/a 0.98 n/a Inside Location R -Val. Comments 2 0 2 L a4 on ab on ab on Grade ab on Grade REMARKS • EnergyPro 3.1 Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 User Number: 5533 Job Number: 12 of 28 F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 101 0.76 0.0 0 Master Suite, Bdrms 2 & 3 Slab Perimeter 25 0.76 0.0 0 Master Suite, Bdrms 2 & 3 Slab Perimeter 49 0.76 0.0 0 Living/Kitchen/Dining/Ent Slab Perimeter 117 0.76 0.0 0 Livin /Kitchen/Dining/Ent Slab Perimeter 64 0.76 0.0 0 Guest Suite HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2 _Central Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -3 Oydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split AIr Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. AMERICAN CG32-100T88-4N" Large Gas Recirc/Time+Temp 1 88,000 96 0.82 0.0239 0.0 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS • EnergyPro 3.1 Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 User Number: 5533 Job Number: 12 of 28 Computer Method Summary (Part 3 of 3) C -2R ndrew Pierce Corporation 5/9/05 iojecfTitIe — -Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, eavyweight 104 3_50 28 0_98 n/a 0 Guest Suite / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 21 0.76 0.0 0 Guest Suite HVAC SYSTEMS Heating Equipment Type (furnace, heat pump, etc.) *y'-dronic Piping System Name Minimum Distribution Type Efficiency and Location (AFUE/HSPF)(ducts/attic, etc.) Pipe Pipe Insul. Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc,) Duct Thermostat R -Value Type Duct Thermostat R -Value Type Location / Comments Location / Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS r -- I • Energypro 3.1 Run Initiation Time: 05/09/05 09:49:12 Run Code: 1115657352 By EnergySoft User Number: 5533 Job Number: 13 of 28 Computer Method Summary (Addendum) C -2R rew Pierce Corporation 519105 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on me aaequacy or me special fusuncauan ano uocurnencauun suurnuieu. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1135 sqft Covered Slab Floor, 3.50" thick at Master Suite, Bdrms 2 8 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 577 sqft Exposed Slab Floor, 3.50" thick at Master Suite, Bdrms 2 & 3 The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 228 sqft Covered Slab Floor, 3.50" thick at Living/Kitchen/Dining HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1349 sqft Exposed Slab Floor, 3.50" thick at Living/Kitchen/Dining The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 366 sqft Covered Slab Floor, 3.50" thick at Guest Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 104 sqft Exposed Slab Floor, 3.50" thick at Guest Suite HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS [-A �rovider. The HERS rater must document the Held verification and diagnostic testing of these measures on a form CF -6R. anto The RVAC- yS s ef—m "RVAC--f inc u es Ketrigerant Charge and Airflow Credit (ora certified HERS ra er must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -611 Form. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit or a TXV). A certified HERS rater must provid verifification of the TXV, or measure the Refrigerant Charge and Airflow. �e FI1TPiC Sys em 'RPA=2 is using reduced uc leakage to comply and must nave cliagnostic site testing of ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. TFe HVXC-Sys em `HVAC- includes Refrigerant Charge and Airflow Credit (ora certified rater must prove verifification of the TXV, or measure the Refrigerant Charge and Airflow. �e HVA System -3 is using reduced uc leakage to comply and must have diagnostic site es ng o uc ea ag performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form, EnergyPro 3.1 By Energy5oft User Number: 5533 Job Number: Page: 14 of 28 1 EnergyPro 3.1 By Energy5oft User Number: 5533 Job Number: Page: 14 of 28 1 -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY CROJECT NAME Andrew Pierce Corporation STEM NAME ----- HVAC -1 Number of Systems 1 Heating System Output per System — 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 52.0 ;Cooling System Output per System 58,000 Total Output (Btuh) 58,000 j Total Output (Tons) Total Output (Btuh/sgft) 4.8 33.9 Total Output (sgft/Ton) 354.2 Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) V Airflow (cfm/Ton) 2,000 2,000 1.17 413.8 Outside Air (%) F 0.0 I Outside Air (cfm/sgft) 0.00 Note_ values above given at ARI conditions 26.0 of Outside Air 0 cfm I 69.6 of 1111.0 / 77.6 OF Outside Air 0 cfm I 74.4 161.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 5A- 5/9/05 AREA 1,712 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 878 17,656 0 383 16,720 0 883 836 0 0 0 0 0 1 0 0 0 0 883 836 19,422 0 18,392 HVAC EQUIPMENT SELECTION CARRIER 38TXA060 41,975 6,634 89,000 Total Adjusted System Output 41,975 6,634 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm an 12 am 5YUNKUMt 1 KI(;J (Airstream I emperatures 69.6 of 69.6 of M 111.40F 0 Supply Fan 2000 cfm Heating Coil 6% Return Air Ducts V 74.4/61.0OF 74.4/61.OoF . 54.7/53.60F Supply Fan 2000 cfm Cooling Coil �% Return Air Ducts Y Supply Air Ducts 111.0 of ROOMS 70.0 OF Supply Air Ducts IR 55.1 / 53.8 of 47.2% R.H. ROOMS 74.0 / 60.9 of J _EnergyPro 3.1 By EnergySoft – User Number: 5533 Job Number: Page: 15 of 28 -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ,!;Number of Systems Heating System Output per System l• -- Total Output (Btuh) Output (Btuh/sqft) :Cooling System Output per System Total Output (Btuh) ( Total Output (Tons) Total Output (Btuh/sqft) I Total Output (sgft/Ton) :'Air System i CFM per System Airflow (cfm) Airflow (cfm/sqft) I Airflow (cfm/Ton) • Outside Air (%) Outside Air (cfm/sqft) Note: values above given at ARI conditions L- —.. ---._- 26.0 of Outside i 0 cfm 69.4 OF F 111.0/77.6OF Outside A i 0 cfm 89,000 89,000 56.4 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM Sensible 1,134 22,553 0 563 24,350 0 1,128 1,218 0 0 0 0 0 0 0 0 — 0 1,128 1,218 24,808 0 26,785 HVAC EQUIPMENT SELECTION 2,000 2,000 CARRIER 38TXA060 42,034 6,636 89,000 1.27 413.8 0.0 Total Adjusted System Output 42,034 6,636 89,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAKAug 2 pm F Jan 12 am >Tk,HKUIVItIKIGJ (Airstream iemperaturesat lime 69.4 of 69.4 of 111.2 of -�Tj� Supply Fan 2000 cfm 1074.5161.1 of EnergyPro 3.1 By EnergySoft Heating Coil �, Return Air Ducts %4 74.5161.10F 74.5 / 61.1 °F. 54.8 153.7 of 0 Supply Fan 2000 cfm Cooling Coil Rcfi irn Air rL im-z User Number: 5533 Job Number: Supply Air Ducts 110.7 OF ROOMS 70.0 of Supply Air Ducts 55.3 / 53.9 of 47.4% R.H. ROOMS 74.0 / 60.9 of Page: 16 of 28 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Andrew Pierce Corporation SYSTEM NAME L HVAC -3 ''Number of Systems '!Heating System T Output per System — I Total Output (Btuh) Output(Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) I Total Output (Btuh/sgft) Total Output (sgft/Ton) ;Air System ii CFM per System Airflow (cfm) Airflow (cfm/sgft) •Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 26.0 of 69.5 of �f Outside Air 0 cfm 69.5 OF ;111.0/77.6OF out�tlAir 7' 0 cfm 74.4/59.4 of Supply Fan 800 cfm 1 35,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 35,000 74.5 Latent 23,600 23,600 2.0 TOTAL SYSTEM LOAD 519105 FLOOR AREA 470 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 288 6,699 0 204 8,696 0 435 335 0 0 0 0 0 0 0 0 0 335 435 7,369 0 800 800 CARRIER 38TXA024 19,298 0 1.70 _ 406.8 Total Adjusted System Output 0.0 (Adjusted for Peak Design Conditions) 19,298 0 0.00 TIME OF SYSTEM PEAK F Aug 2 pm 69.5 of 110,60F Heating Coil 74.4 / 59.4 of 74.4 / 59.4 of EnergyPro 3.1 By EnergySoft' O 9,566 35,000 35,000 Jan 12 am Supply Air Ducts 110.10F ROOMS 70.0 of Return Air Ducts 51.7 150.5 of Supply Fan Cooling Coil 800 cfm User Number: 5533 �, Return Air Ducts Y Job Number: Supply Air Ducts 52.1 / 50.7 of 41.8% R.H. ROOM 74.0 159.3 of Page: 17 of 28 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 18 of 28 ROJ ECT NAME Andrew Pierce Corporation DATE 5/9/05 YSTEM NAME HVAC -1 FLOOR AREA 1,712 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite, Bdrms 2 & as er w e, rms 1 1 878 17,656 0 878 17,656 0 383 16,720 PAGE TOTAL 1 878 17,656 Ol 383 16,720 TOTAL 1 878 17,656 011 383 16,720 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 18 of 28 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:19 of 28 OJECT NAME Andrew Pierce Corporation DATE 519105 SYSTEM NAME HVAC -2 FLOOR AREA 1,577 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living/Kitchen/Dining/Er rvmg iR"�he`n/ ming t 1 1,134 22,553 0 1,134 22,553 0 563 24,350 PAGE TOTAL 1,134 22,553 0 563 24,350 TOTAL 1,134 22,553 0 563 24,350 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:19 of 28 ROOM LOAD SUMMARY --!.PROJECT NAME Andrew Pierce Corporation DATE 5/9/05 YSTEM NAME HVAC -3 FLOOR AREA 470 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Suite 6uest buite 1 288 6,699 0 288 6,699 0 204 8,696 PAGE TOTAL 2881 6,666 o 2041 8,696 TOTAL 288 6,699 0 1 204 8,696 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:20 of 28 ROOM HEATING PEAK LOADS ndrew Pierce Corporation Room Information 'Room Name Floor Area Indoor Dry Bulb Temperature Conduction 4 R-38 Roof (R.38.2x14.16) _ Double Metal Tinted Default R-21 Wall (W.21.2x6.16) —,__ Double NonMtl Tinted__ Double Non_Mtl Tinted Double_NonMtl Tinted Slab -On -Grade i i i r Design Conditions Master Suite, Bdrms 2 & 3 Time of Peak Jan 12 am 1,712 Outdoor Dry Bulb Temperature 26°F 70 of Area x X x X x X X x x x x x x x x x x x x x x x x x x x x x x X X x x x X X X x X U -Value X X x X X x x x x x x x x x x x x x x x x x x x x x x x x x X x X X X X X X X AT of = = = = = = = = = = = = = = = = = = _ = = = = = = = = = = = = = = = = = = = = Btu/hr 1,708.9 0.0280 44.0 2,106 3.1 0.8000 44.0 109 939.3 0.0592 44.0 2,447 128.0 0.5500 44.0 _ 3,098 31.0 0.6000 44.0 818 106.7 0.5400 44.0 2,535 perimeter= 126.0 44.5 5,607 _ _ Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16,720 Infiltration: 1.00 x 1.064 x F 1,712 x 9.60 x = 0.00 160 x 44 p Schedule AiF Sensible Area Ceiling Height ACA Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,720 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 21 of 28 ROOM HEATING PEAK LOADS Wndrew Pierce Corpore Room Information Room Name Floor Area Indoor Dry Bulb Temperature Conduction rR-38 Roof (R.38.2x14.16) A-21 Wall (W.21.2x6.16) ;Solid Wood Door !Double NonMtl Tinted ,Double NonMtl Tinted Double NonMtl Tinted Slab -On -Grade I I I i Area t--- 15/9/05 Design Conditions Dining Time of Peak Jan 12 am 1,577 Outdoor Dry Bulb Temperature 26OF 700 U -Value AT °F Btu/hr Items shown with an asterisk (f') denote conduction through an interior surface to another room. Page Total: 24,350 Infiltration: I 1.00 x 1.064 x 1,577 x 11.20 x 0.00 / 60 x _ Schedule Air Sensible Area CeiIinT g Refight ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 24,350 EnergyPro 3.1– By EnergySoft User Number: 5533 Job Number: Page: 22 of 28 1,577.0 X X x x x X x x x x x x x x x X X X X x x x x x x x X X X X x x X x X x X x x 0.0280 X X x X x X x x x x x X x x x x X X x x x X X X X X x X X X X x x x x X X X x 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,943 1,300.5 0.0592 44.0 3,388 22.0 0.3872 44.0 375 352.0 0.5500 44.0 8,518 87.5 0.5400 44.0 2,079 25.0 0.6000 44.0 660 perimeter =166.0 44.5 7,387 —_ Items shown with an asterisk (f') denote conduction through an interior surface to another room. Page Total: 24,350 Infiltration: I 1.00 x 1.064 x 1,577 x 11.20 x 0.00 / 60 x _ Schedule Air Sensible Area CeiIinT g Refight ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 24,350 EnergyPro 3.1– By EnergySoft User Number: 5533 Job Number: Page: 22 of 28 ROOM HEATING PEAK LOADS oject Title Date ndrew Pierce Corporation 15/9/05 Room Information Design Conditions Room Name Guest Suite Time of Peak Jan 12 am Floor Area 470 Outdoor Dry Bulb Temperature 26OF !Indoor Dry Bulb Temperature 70°F Conduction surface Area Area X x x X x x x x X X x X X x x X X X X x X X x x X X X x X X x U -Value X X x X x X x x X X x X X X x X X X x X X X x x x X X x X X x AT of = = = = = = = _ = = = = = = = = = = = - = = = = — = = _ Btu/hr R-38 Roof_ (R.38.2x14.16) 470.0 0.0280 44.0 579 R-21 Wall (W.21.2x6.16) 'Double NonMtl Tinted__ !Double NonMtl Tinted — 745.0 0.0592 44.0 1,941 10.0 0.6000 44.0 264 53.2 0.5400 44.0 1,264 ,Double NonMtl Tinted ;Double NonMtl Tinted Default iSlab-On-Grade 24.0 0.5500 44.0 581 10.8 0.6000 44.0 285 perimeter= 85.0 44.5 3,782 — --- - -- - ---- - _ i,. - -- ---- --- r - - -- ---- --- - ---- -- — ---- -- ---- -_ i -- - - -- - I--_— Items shown with an asterisk (') denote conduction through an interior Infiltration: [ 1.00 X —1.064 X Schedule Air Sensible Fraction to another room. 470 x _9.70 Ceiling Height 0.00 160 Ac. J Page Total: ® pT 8,696 I TOTAL HOURLY HEAT LOSS FOR ROOM 8,696 _ _ EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 23 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY Andrew Pierce Corporation 5/9/05 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction IR -38 Roof (R.38.2x14.16) �Double Metal Tinted Default R-21 Wall (W.21.2x6A6) �ouble NonMtl Tinted Double N_onMtl Tinted Double NonMtl Tinted Area 1,708.9 X 3.1 X 939.3 X 128.0 X 31.0 X 106.7 X X x X Master Suite, BdrTns 2 & 3 74°F 112°F U -Value X X X X X X DETD 1 0.0280 55.0 0.8000 38.0 0.0592 34.6 0.5500 38.0 0.6000 38.0 0.54001 38.0 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC 38°F Btu/hr 2,632 94 1,924 2,675 707 2,189 10,222 Btu/hr r------ ISkylight _ Window _ - _ _ _ 'Window Window - _ Window (Window Window Window Window (Window - - ------- (Skylight) ( 0.0 X x x X X X x X x X 15 + 15 + 15 + '15+ 15 + 15 + 15 + 1 + 15 + 15 + 3.1 X x x X x x X x X32) x 152) X X 0.529 = = = = = = = = = = 249 (East) ( 0.0 48.0 73) 0.512 1,794 (East) ( 0.0 15.0 73)x 0.512 561 (East) ( 0.0 37.8 73)x 0.512 1,413 (East) ( 0.0 4.4 73)X 0.512 164 (East) (East) ( 0.0 6.0 73)x 0.512 224 ( 0.0 6.0 -73)x 0.512 224 (South) ( 12.5 0.0 32)X 0.512 96 (South) ( 20.0 0.0 0.512 154 (South) (F 40.0 0.0 32)x 0.512 307 Sched. Page Total 5,187 Internal Gain Frac. Area Heat Gain Btulhr Lights- 1.00 X 1,712 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Occupants_ 1.00 x 1,712 X 255 Btuh/occ. I 0 sgft/OCc. = 0 Receptacle _ 1.00 X 1,712 x 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 +Process `1.00 x 1,712 x 0.000 Watts/sqft X 3.413 Btuh[Watt = 0 Infiltration: L�_1_0� X �_ 1.064 x 1,712 x - 9.60 x 0.00 / 60] 38 = 0 Schedule Air tieAreaArea ening Height ACR QT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,656 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants _ 1.00 x 1,712 x 225 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 x 1,712 x 0.000 Watts/sqft x 3.413 Btuh/Watt = Process- 1.00 __f-^ 1.00 x 1,712 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: L[ -1_00 x - 4,771 x 1,712 x 9.60 x 0.00 / 6a] 0.00000 = �� Schedule Air Latent) Area Ceiling Heigh ACH �W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 [EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:24 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY • Andrew Pierce Corporation 5/9/05 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master Suite, Bdrms 2 & 3 74° F 112°F 380E Conduction Area U -Value DETD 1 Btu/hr X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF ''Window — (South) (Window (West) Window (West) C_ I—` I_ i — Page Total SC Btu/hr 20.0 X X x x x x x x x x 15 + + + + + + + + + + 0.0 X x x x x x x x x x 32) X X )x )x )x )x )x )x )x 0.512 = = = = = = = = = = 154 0.0 15 16.0 73) 0.512 598 0.0 1 40.0 73)X 0.512 1,495 Sched. Page Total 2,2a7 Internal Gain Frac. Area Heat Gain Btu/hr Lights _ 1.00 x 1,712 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 x 1,712 X 255 Btuh/occ. / 0 sqftlocc. = 0 Receptacle 1.00 X 1,712 X 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Process 1.00 x 1,712 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: 1_00 x 1.064 x 1,712 x 9.60 x 0.00 / 60] 38 = Schedule Air sensible Area Ceiling Hl igfft ACH pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,656 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants1.00 x 1,712 x 225 Btuh/OCC. / 0 sgft/OCc. = 0 Receptacle 1.00 x 1,712 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 ;Process 1.00 X 1,712 X 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Infiltration: 1.00 x C 4,771 x 1,712 X9.60 x 0.00 / 60] 0.00000 = �0 t`Schedule Air catent— Area Ceilinglieigh ACH pW Fraction [TOTAL TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 25 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation Project Title 5/9/05 Date Room Name Living/Kitchen/Dining Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 740F 112°F 380F Conduction Area U -Value DETD 1 Btu/hr JR -38 Roof (R.38.2x14.16) ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 162.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 1,577.0 X �R-21 Wall (W.21.2x6.16) 15)x 34.6 1,300.5 X Solid Wood Door _ 44.0 34.6 22.0 X Double NonMtl Tinted 44.0 38.0 352.0 X Double NonMtl Tinted 24.0 38.0 87.5 X Double NonMtl Tinted 32)x 38.0 25.0 X - --- 0.512 410 17.5 32)x i- 287 (West) 48.0 x L_ 1,794 (West) 10.0 X X ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 162.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 55.0 = 2,429 -- X 15)x 34.6 = 2,664 X 44.0 34.6 = 295 X 44.0 38.0 = 7,357 X 24.0 38.0 = 1,796 X 32)x 38.0 = 570 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Window_ 'Window Window - •Window (.Window ,Window Window ,Window :Window -- -� Mindow� -J Page Total 15,110 Sc Btulhr (North) (North) ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 162.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 x X x x X x x x X x 15,+ 15' + 15 + 151+ 1 + 15 + 15 + 15,+ 15 + - 1 + 54.0 X X X X X x x x X x 15)x x 0.512 = = = = = = = = = = 415 44.0 15)X 0.512 338 (North) 44.0 15)X 0.512 338 (East) (South) (South) (South) 24.0 73) 0.512 897 0.0 32)x 0.512 1,244 25.0 32)x 0.512 410 17.5 32)x 0.512 287 (West) 48.0 73)X 0.512 1,794 (West) 10.0 73)X 0.512 374 (West) 18.0 73)x 0.512 673 Sched. Page Total 6,770 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,577 X 0.000 Watts/sgft X 3.413 BtuhlWatt = 0 Occupants 1.00 x 1,577 X 255 Btuh/occ. / 0 sqft/occ. = 0 Receptacle _ 1.00 X 1,577 x 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 (Process _ -- 1.00 x 1,577 x 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 Infiltration: 1.00 X L _ 1.064 X 1,577 X , _ 11.20 X 0.00 / 6�] 38 = 1 0] I -Schedule Air Sensible Area Ceiling Heist ACH n T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,553 Sched. Latent Gain Frac. Area Heat Gain Btulhr !Occupants 1.001 x 1,577 x 225 Btuh/occ. / 0 sgft/occ. = 0 Receptacle- _ 1.00 x 1,577 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0 LPr- cess _ � 1.00 X 1,577 X 0.000 Watts/sgft X 3.413 BtuhMatt = 0 Infiltration: L1.00 x _ 4,771 x 1,577 x 11.20 x 0.00 / 60] 0.00000 = 0 Schedule Air Latent) Area Ceiling Height AC pW •Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o lEnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 26 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Andrew Pierce Corporation 5/9/05 Project Title Date • C7 Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living/Kitchen/Dining 74° F 112°F 38° F Conduction Area U -Value DETD' Btu/hr X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Page Total SC Btu/hr (West) ( 0.0 ( ( ( ( ( ( ( ( ( x x x x x x x x x x 15 + + + + + + + + + + 18.0 x x x x x x X x x x 73) x )x )x )x )x )x )x )x )x )x 0.512 = = = = = = = = = 673 Sched. Page Total 673 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,577 x 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 !Occupants_ _ 1.00 x 1,577 x 255 Btuh/occ. / 0 sgft/Occ. = 0 (Receptacle1.00 x 1,577 x 0.000 Watts/sgft x 3.413 BtuhfWatt = 0 ;Process _ ~� 1.00 x 1,577 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: CE 1A0 x 1.064 x 1,577 x _ 11.20 x 0.00 /60 38 = �0 Schedule Air Sensible Area Ceiling Heigh ACH p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,553 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,577 x 225 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 x 1,577 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process I� 1.00 x 1,577 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0 Infiltration: L 1_00 x 4,771 x 1,577 x _11.20 x 0.00 / 60] 0.00000 = �0 Schedule Air Latent Area Ceiling Fright NCH QN1 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 r nergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 27 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY Andrew Pierce Corporation 5/9/05 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suite 740F 112°F 380E Conduction Area U -Value DETD' Btu/hr jR-38 Roof (R.38.2x14.16) 470.0 X �R-21 Wall (W.21.2x6.16) 724 745.0 X jDouble NonMtl Tinted = 10.0 X Double NonMtl Tinted 38.0 53. X ,Double NonMtl Tinted 24.01 X Double NonMtl Tinted Default 10.8 X `_ X I x X X 55.0 = 724 X 4,318 34.6 = 1,526 X 38.0 = 228 X 38.0 = 1,092 X Orientation 38.0 = 502 X Btu/hr 38.0 = 246 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 4,318 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (East) ( 0.0 x 15-+ 10.0 X 73)X 0.512 = 374 Window (South) ( 0.0 x 15 + 20.0 X 32)X 0.512 = 328 (Window_ (South) ( 0.0 x 15 + 24.0 X 32)x 0.512 = 393 _ !Window_- (South) ( 0.0 x 151+ 20.0 X 32)x 0.512 = 328 _ _ /Window (West) ( 0.0 x 1S + 4.4 X 73)X 0.512 = 164 (West) ( 0.0 x 15 + 4.4 X 73)X 0.512 = 164 �Wlndow WIndow (West) ( 0.0 x 15 + 4.4 x 73)X 0.512 = 164 Window (West) ( 0.0 x 15 + 10.8 X 73)X 0.590 = 465 F-� ( X t X )X = .I Sched. Page Total 2,381 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 470 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Occupants 1.00 x 470 X 255 Btuh/occ. / 0 sgft/occ. = 0 Receptacle 1.00 X 470 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 X 470 X 0.000 Watts/sqft x 3.413 BtuhMatt = 0 Infiltration: [ 1.00 x 1.064 x 470 x 9.70 x 0 60] Schedule Air_ Sensible Area Ceili-ng Heigh AC 0.0 Q Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,699 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants_ _- 1.00 X 470 x 225 Btuh/OCC. / 0 sgftlOCC. = AO !Receptacle _ 1.00 x 470 X 0.000 Watts/sgft x 3.413 Btuh/Watt = lProcess 1.00 x 470 x 0.000 Watts/sgft x 3.413 Btuh/VVatt = Infiltration: �� 1.0o x _ a,777 x azo x - s.7o x o.00 / 60] -Schedule Air Latent Area ceiling Height ACH Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o iEnergyPro 3_1 By EnergySoft User Number: 5533 Job Number: Page: 28 of 28 • 0 Title 24 Report CEC Approved 2001 Building Energy Efficiency Standards Job Name Clive Clark Tradition Country Club 78-691 Deacon Drive La Quinta, Ca. 92253 Prepared For Michael Kiner Associates, Inc 70-177 Highway 111, Suite 200 Rancho Mirage, ca. 92270 760-324-3360 CIT`r OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA ,L' ! 7• o gy S7 Prepared By Jack LaFontaine ti ' CABEC Certified Energy Analyst # R 01-03-262 EMSEnergy Management Services 41-485 Adams Street,.Unit C — Bermuda Dunes, Ca. 92203 — (760) 360-4631 / Fax (760) 360-3074 C20 License No. 315890 — E-mail: freon.iackOverizon.net Cal Title 24 Reports - Manual -D Duct Design - HERS Rater - Tight Duct Testing - Air Balance Testing - Consulting • 0 • EMSEnergy Management Services Note to Plan Checker, Inspectors & Builder Project Name: Clive Clark New Residence Job Number: 0821004 Project Designer: Michael Kiner Associates, Inc. This Building COMPLIES by 16.2 % better than standard. (Energy Star rated) • A compliance credit has been used for Controlled Sleeping Areas. • A compliance credit has been used for High Mass Design. • A compliance credit has been used for Radiant Barrier Attic Spaces. Sensible cooling and heating loads are indicated on pages marked HVAC System Heating and Cooling Loads Summary, for the HVAC contractor's information. The HVAC equipment specified is 80% AFUE furnaces and 13+ SEER air conditioners with R410A refrigerant. (Federal EPA mandate for 13 SEER effective Jan. 23, 2006). DHW heaters distribution systems use Recirc/Time+Temp and Pipe Insulation. The minimum Recovery Efficiency is 0.58 rated. External tank insulation is not required. 41-485 Adams Street, Unit C — Bermuda Dunes, Ca. 92203 — (760) 360-4631 / Fax (760) 360-3074 C20 License No. 315890 — E-mail: freon.iack(aDverizon.net Cal Title 24 Reports - Manual -D Duct Design - HERS Rater - Tight Duct Testing - Air Balance Testing - Consulting , t• I" I TITLE 24 REPORT Title 24 Report for: Clive Clark New Residence (Tradition CC) 78-691 Deacon Drive East La Quinta , Ca. 92253 Project Designer: Michael Kiner Associates, Inca 70-177 Highway 111, Suite 200 Rancho Mirage, Ca. 92270 760-324-3360 Report Prepared By: J LaFontaine CEA R01-03-262 Energy Management Service 41- 485 Adams Street, Unit C' Bermuda Dunes, CA 92201 760-360-4631 Job Number: 0821004 Date: 8/28/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: 0821004 User Number: 5021 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary 0 r 1 2 3 7 9 15 EnergyPro 3.1 By EnergySoft Job Number: 0821004 User Number: 5021 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Clive Clark New Residence (Tradition CC) _ 8/28/2004 • Project Title Date 78-691 Deacon Drive East La Quinta Project Address Building Permit # Energy Management Service 760-360-4631 Plan Check /Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only 0 • GENERAL INFORMATION Total Conditioned Floor Area: 3,759 ft2 Average Ceiling Height: 10.5 ft Total Conditioned Slab Area: 3,759 ft2 Building Type: (check one or more) RI Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Tvoe Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-21 Wall (W.21.2x6.16)5/8x5/8 Wood 0.057 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 1.5 1.27 0.80 None ❑ x❑ ❑ x❑ Left (East) 36.0 0.30 0.30 Bug Screen x❑ ❑ ❑ x❑ Left (East) 45.0 0.31 0.27 Bug Screen x❑ ❑ ❑ x❑ Left (East) 70.5 0.31 0.31 Bug Screen X❑ 1:1 El a]Rear (South) 343.4 0.31 0.31 Bug ScreenX❑ ❑ ❑ x❑ Right (West) 40.0 0.30 0.26 Bug ScreenX❑ ❑ ❑X❑ Right (West) 20.0 0.30 0.30 Buq Screen x❑ ❑ ❑ x❑ Skylight 12.2 0.53 0.65 None ❑ x❑ ❑X❑ Front (North) 144.0 0.30 0.26 Bug Screen x❑ ❑ ❑X❑ Front (North) 15.0 0.31 0.31 Bug ScreenX❑ ❑ ❑X❑ Rear (South) 29.2 0.30 0.30 Bug ScreenX❑ ❑ ❑ x❑ Right_ (West) 133.0 0.31 0.31 Bug ScreenX❑ ❑ ❑ X❑ Run Initiation Time: 08/28/04 13:29:53 Run Code: 1093724993 Ener Pro 3.1 By Ener Soft User Number: 5021 Job Number: 0821004 Pa e:3 of 17 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R •Clive Clark New Residence (Tradition CC) 8/28/2004 Project Title Date 78-691 Deacon Drive East La Quinta Project Address Building Permit # Energy Management Service 760-360-4631 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,759 ft2 Average Ceiling Height: 10.5 ft Total Conditioned Slab Area: 3,759 ft2 0 Building Type: (check one or more) © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type . Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (South) 24.0 0.30 0.26 Bug Screen a ❑ ❑ o El 0 ❑ ❑ ❑ ❑ ❑ ❑ ❑ 11 1:1 E] 1111 1-1 El El F ❑ El 1111 El El El 1111 ❑❑ El F1 ❑❑ 1111 1111 El El Run Initiation Time: 08128/04 13:29:53 Run Code: 1093724993 Ener Pro 3.1 By Ener Soft User Number: 5021 Job Number: 0821004. Pa e:4 of 17 j Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Clive Clark New Residence (Tradition CC) 8/28/2004 • Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone I HVAC Split System Central Furnace 80% AFUE Ducts in Attic Central Furnace 80% AFUE Ducts in Attic 42 Sethack Zone II HVAC S lip t System 42 Setback Zone III HVAC Split System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 13.2 SEER Ducts in Attic 42 Sethack Zone I HVAC Split System Split Air Conditioner 132 SEER Ducts in Attic Split Air Conditioner 13.5 SEER Ducts in Attic 4 2 Sethack Zone II HVAC Split System 4.2 Setback Zone III HVAC Split System WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value GE GG50T06TVF(6year)T24 Small Gas Recirc/Time+Temp 1_ 40,000 50 0.62 n/a n/a GE GG30SO6AVF(6year) Small Gas Pipe Insulation 1 30.000 30 0.58 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design respo sibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verificatio an approved HERS rater. Designer or r (pAersiness Prof s Code) Documentation Author Name:Jb4VtA----Name: J LaFontaine CEA R01-03-262 Title/Firm: Michael Kiner Associates, Inc. Title/Firm: Energy Management Service Address: 70-177 Highway 111, Suite 200 Address: 41- 485 Adams Street, Unit C Rancho Mirage, Ca. 92270 — BermufilslDunes, CA 92201 Telep�g�e: Lic.;. (signature) 'v(bate) Enforcement Agency Name: Title/Firm: Address: Telephone: ne: ature/stain (dat IEnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Paae:5 of 17 1 Certificate of Comaliance: Residential (Addendum) CF -1 R Clive Clark New Residence Tradition CC 8/28/2004 roject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "Zone I HVAC Split System" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Area 1. The HVAC System "Zone I HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manu 1. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 840 sqft Covered Slab Floor, 3.50" thick at Mbr-Br2-Br3-Laun-Powd-Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 757 sqft Exposed Slab Floor, 3.50" thick at Mbr-Br2-Br3-Laun-Powd-Hall The HVAC System "Zone II HVAC Split System" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Zone II HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential anua. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 764 sqft Covered Slab Floor, 3.50" thick at Ding. Kit. Livg. Den. Entry HIGH MASS Design(see C -2R) - Verify Thermal Mass: 936 sqft Exposed Slab Floor, 3.50" thick at Ding. Kit. Livg. Den. Entry The HVAC System "Zone III HVAC Split System" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas The HVAC System "Zone III HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential anua. HIGH MASS Design(see C -21R) - Verify Thermal Mass: 298 sqft Covered Slab Floor, 3.50" thick at Guest Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 164 sqft Exposed Slab Floor, 3.50" thick at Guesj Suite HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field Run Initiation Time: 08/28/04 13:29:53 Run Code: 1093724993 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page:6 of 17 • • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a *§150(.): Minimum R-19 ceiling insulation. E] § 150(b): Loose fill insulation manufacturer's labeled R -Value. 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does *not ❑§ X apply to exterior mass walls). ❑ *§150(d): Minimum R-13 raised Floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118i Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. IAI §`150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems: 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page:7 of 17 w 0 • Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protec:ed by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. FX'§ 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) El§118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance tp the kitchen. a§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page:8 of 17 Computer Method Summary (Part 1 of 3) C -2R Clive Clark New Residence (Tradition CCl �.� KA 8/28/2004 roject Title 8-691 Deacon Drive Fast I a (;luinta Total Conditioned Floor Area: 3,759 ft2 Date Project Address Building Type: Single Fam Detached o Building Permit # Fnerav Management Service Total Fenestration Area: 760-360-4631 Number of Dwelling Units: Docum Cation Autfror Total Conditioned Volume: 39,390 ft 3 Telephone Plan Check/Date Commuter Performance 3,759 ft 2 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone U Source Energy Use Standard Proposed Compliance .:. (kBtu/sf-yr) Design Design Margin Space Heating 3.64 3.63 0.01 fi� Space Cooling 36.04 27.93 8.11 Domestic Hot Water 7.58 8.06 -0.48 Totals 47.26 39.62 7.64 Percent better than Standard: ] 16.2% �.� KA El BUILDING COMPLIES 71 Total Conditioned Floor Area: 3,759 ft2 Floor Construction Type: ❑ Raised Floor[g] Slab Floor Building Type: Single Fam Detached o 9-21 XI/all-A41-21-2y6_161— Building Front Orientation: (North) 0 deg Total Fenestration Area: 24.3% Number of Dwelling Units: 1.00 Total Conditioned Volume: 39,390 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 3,759 ft 2 BUILDING ZONE INFORMATION Zone Name 7nne I HVAC S lid t System Zone II HVAC Slint System one III HVAC Split System # of Floor Area Volume Units 1 597 15 172 n 49_ 1,700 2()()S 0 45 462 415 0.12 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Ronf 1,596 0.024 go 99 Wall _ 340 0 057 0 go nnnr 20 0.387 0 A0_ Wall 149 0.059 90 90 Wall 450 0.059 g0 An Wall 79 0 059 180 90_ Wall 167 0.059 270 go Rnnf 1688 0.024 180 9? Wall 172 0 059 0 90 Wall 52 0 059 A0 90 Wall 206 0.059 180 90_ Wall 31 0.059 270 An Wall 362 0.059 270 —90_ Roof 462 0.024 0 —92 Wall 169 0 059 —Q A0_ Wall 225 0.059 90 90 Wall 102 0 059 180 An Wall 194 0 059 270 90 Solar Gains Y / N Form 3 Reference Thermostat Zone Type Type SIPPping SIPQpjngStat I ivin9 iving,Stat Sleepip9 Sleepin9Stat �1 ] c::.. ::: �.� KA El Wall Solid Wood Door - Y 4 1 o 9-21 XI/all-A41-21-2y6_161— El 0 : ;.. V . V _ 04 W. U "I E .:. VP El w. 1w P 1 U . fi� a E N El Vent Hgt. Area -2 n/a n/a n/a Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Paae:9 of 17 1 Computer Method Summary (Part 2 of 3) C -2R 8/28/2004 Date U- Act. Glazing Type Area Factor SHGC Azm. Tilt Location/ Comments 1- Skylight Left (East) 1 5 1.270 Q80 90_ 92 SkyfightSolaTube 10" rfin Zone I,Mhr SO Rr3 i Ifil 2 Window Left (East) 36.0 0.300 0.30 90 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Uti1 3 Window Left (East) 15.0 0.310 0.27 90 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Uti1 4 Window Left (East) 30.0 0.310 0.27 90 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Uti1 5 Window Left (Egst) 12.5 0.310 0.31 90 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Uti1 6 Window Left (East)_ 20.0 0.310 0.31 90 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Uti1 Z Window Left (East) 20.0 0.310 0.31 90 90 Hurd Primed Wood Zone I Mbr.Br2 Br3.Uti1 8 Window Rear (South 32.0 0.310 0.31 180 90 Hurd Primed Wood Zone I,Mbr.Br2.Br3.Uti1 6 Window Rear (South) 96.0 0.310 0.31 180 -90 Hurd Primed Wood Zone I Mbr.Br2.Br3.Util 16 Window Right (We4 40.0 0.300 0.26 270 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Uti 11 Window Right (West) 20.0 0.300 0:30 270 90 Hurd Primed Wood Zone I.Mbr.Br2.Br3.Util 12 Skylight Rear (South) 12.2 0.530 0.65 180 22 ODL Skylites.Acrylic White Me Zone II.Dg.Kit.Lvg.Den 13 Window Front (North) 48.0 0.300 0.26 0 90 Hurd Primed Wood Zone II,D.g Kit Lyg.Den 14 Window Front (North) 48.0 0.300 0.26 0 90 Hurd Primed Wood Zone II.Dg.Kit.Lvg.Den 15 Window Front (North) 48.0 0.300 0.26 0 90 Hurd Primed Wood Zone II,Dg.Kit.Lvg.Den 16 Window Front (North) 15.0 0.310 0.31 0 90 Hurd Primed Wood Zone II.Dg.Kit.Lvg.Den 17 Window Left (East) 18.0 0.310 0.31 90 90 Hurd Primed Wood Zone II,Dg.Kit.Lvg.Den 18 Window Rear (South) 20.2 0.310 0.31 180 90 Hurd Primed Wood Zone II,Dg.Kit.Lvg.Den 12 Window Rear (South) 29.2 0,300 0.30 180 90 Hurd Primed Wood Zone 11.DQ.K6t.Lvg.Den 20 Window Rear (South) 64.0 0.310 0.31 180 90 Hurd Primed Wood Zone II,Dq.Kit.Lvg.Den 21 Window Rear (South 24.5 0.310 0.31 180 90 Hurd Primed Wood Zone II,Dg.Kit.Lvg.Den 2-2_ Window Rear (South) 64.0 0.310 0.31 180 90 Hurd Primed Wood Zone II.Dg.Kit.Lvg.Den_ 23 Window Right (West) 64.0 0.310 0.31 270 90 Hurd Primed Wood Zone II,Dg.Kit.Lvg.Den 24 Window Right (West) 26.2 0.310 0.31 270 90 Hurd Primed Wood Zone II.Dg.Kit.Lvg.Den 25 Window Right (West) 4.0 0.310. 0.31 270 90 Hurd Primed Wood Zone II.Dg.Kit.Lvg.Den 26 Window Right (West) 4.0. 0.310 0.31 270 90 Hurd Primed Wood Zone II,Dg.Kit.Lvq.Den 27 Window Right (West) 4.0 0.310 0.31 270 90 Hurd Primed Wood Zone II,Dg.Kit.Lvg.Den Window Rear (South) 21.3 0.310 0.31 180 90 Hurd Primed Wood Zone III,Guest Suite 9 Window Rear (South) 24.0 0.300 0.26 180 90 Hurd Primed Wood Zone III,Guest Suite INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 Bug Screen 0.76 4.5 8.0 1.5 0.1 2.0 2.0 3 Bug Screen _ 0.76 5.0 3.0 3.0 0.1 3.0 3.0 4 Bug Screen 0.76 5.0 6.0 3.0 0.1 3.0 3.0 5 Bug Screen 0.76 5.0 2.5 3.0 0.1 3.0 3.0 6 Bug Screen 0.76 8.0 2.5 1. 0. 2� 2.0 7 Bug Screen 0.76 8.0 2.5 1.5 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 4.0 9.0 0.1 8.0 8.0 9 Bug Screen 0.76 8.0 12.0 9.0 0.1 8.0 8.0 10 Buq Screen 0.76 8.0 5.0 1.5 0.1 2.0 2.0 11 Bug Screen 0.76 5.0 4.0 1.5 0.1 2.0 2.0 12 None 1.00 13 Bug Screen 0.76 9.0 5.3 2.0 , 0.1 2.0 2.0 14 Bug Screen 0.76 9.0 5.3 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 16 Bug Screen 0.76 2.5 6.0 6.0 0.1 6.0 6.0 17 Bug Screen 0.76 4.5 4.0 10.0 0.1 10.0 10.0 18 Bug Screen 0.76 6.0 4.7 8.0 0.1 8.0 8.0 19 Bug Screen 0.76 4.5 6.5 8.0 0.1 8.0 8.0 20 Bug Screen 0.76 8.0 8.0 8.0 0.1 8.0 8.0 21 Bug Screen 0.76 7.0 3.5 10.0 0.1 10.0 10.0 22 Bug Screen 0.76 8.0 8.0 10.0 0.1 10.0 10.0 23 Bug Screen 0.76 8.0 8.0 10.0 0.1 10.0 10.0 24 Buq Screen 0.76 7.0 3.7 4.0 0.1 4.0 4.0 25 Bug Screen 0.76 2.0 2.0 4.0 0.1 4.0 4.0 26 Bug Screen 0.76 2.0 2.0 4.0 0.1 4.0 4.0 Bug Screen 0.76 2.0 2.0 4.0 0.1 4.0 4.0 Bug Screen 0.76 8.0 2.7 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page: 10 of 17 Computer Method Summary (Part 2 of 3) C-2R Clive Clark New Residence Tradition CC 8/28/2004 roject Title Date ENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _M Window Rear (, outh) _213_ 0 310 0141 180 90 Hijrd Primed Wood Zone III, st 4 iit 31 Window Right (West) 6.2 0.310 0.31 270 90 Hurd Primed Wood Zone III.Guest Suite 32 Window Right (West) 6.2 0.310 0.31 270 90 Hurd Primed Wood Zone III.Guest Suite 33 Window Right (West) 6.2 0.310 0.31 270 90 Hurd Primed Wood Zone III,Guest Suite 34 Window Right (West) 12.0 0.310 0.31 270 90 Hurd Primed Wood Zone III.Guest Suite INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 8.0 2.7 2.0 0.1 2.0 2.0 31 Bug Screen 0.76 2.5 2.5 1.5 0.1 2.0 2.0 32 Bug Screen 0.76 2.5 2.5 1.5 0.1 2.0 2.0 33 Bug Screen 0.76 2.5 2.5 1.5 0.1 2.0 2.0 34 Bug Screen 0.76 4.0 3.0 1.5 0.1 2.0 2.0 EnerovPro 3.1 By EnergvSoft User Number: 5021 Job Number: 0821004 Paoe:11 of 17 1 Computer Method Summary Insulation R -Val. Depth Location / Comments (Part 3 of 3) C -2R Clive Clark New Residence Tradition CC Slab Perimeter 65 0.76 8/28/2004 roject Title 20 _ 0 Zone Il.Dg.Kit.Lvg.Den Slab Perimeter —52 0.76 Date THERMAL MASS FOR HIGH MASS DESIGN 0.0 0 Zone III,Guest Suite etc.) R -Value Type Area Thick. Heat Central Furnace Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Hea4nu ight 840 _3 50 —28 Concrete Heavyweight 757 3_50 28 09.8 n/a 0_98 n/a 2 0 7onp I Mhr Rr2 Br's LIM / Slab on Grarip Zone I.Mbr.Br2.Br3.Util / Slab on Grade Concrete Heavyweight 764 3_50 _280_98 n/a 2 Zone II pa.Kit.Lva_Den / Slab on Grade Concrete, Heavyweight 936 3_50 28 0_98 n/a 0 Zone II.Do.Kit.Lvg.Den / Slab on Grade Concrete ea eight 298 3.50 --Z@ 0.98 n/a _2 Zone III.Guest Suite/ Slab on Grade PERIMETER LOSSES F2. Type Length Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 85 0.76 0.0 0 Zone I.Mbr.Br2.Br3.Util Slab Perimeter 65 0.76 0.0 —Q Zone I,Mbr.Br2.Br3.Util Slab Perimeter 72 -O-Z$ 20 _ 0 Zone Il.Dg.Kit.Lvg.Den Slab Perimeter —52 0.76 0.0 0 Zone II-Qg.Kit.Lvg.Den Slab Perimeter 51 0.76 0.0 0 Zone III,Guest Suite HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone I HVAC Split System Central Furnace 80% AFUE, Ducts in Attic 4.2 Setback Zone II HVAC Split System Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone III HVAC Split System #ydroni7cFiping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 13.2 SEER Ducts in Attic 4.2 Setback Zone I HVAC Split System Split Air Conditioner 13.2 SEER Ducts in Attic 4.2 Setback Zone II HVAC Split System Split Air Conditioner 13.5 SEER Ducts in Attic 4.2 Setback Zone III HVAC Split System WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. GE GG50T06TVF 6 ear T24 Small Gas Recirc/Time+Temp 1 40,000 50 0.62 n/a n/a GE GG30SO6AVF(6year) Small Gas Pipe Insulation 1 30.000 30 0.58 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS computer Method Summary (Part 3 of 3) C -2R Clive Clark New Residence Tradition CC 8/28/2004 rniact Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Hea0meight 164 3M 28 _QA$ n/a _Q 7nne III ,Guest Suite / Slab on Gradp PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 36 0.76 0.0 0 Zone III,Guest Suite HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments *ydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 08/28/04 13:29:53 Run Code: 1093724993 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page: 13 of 17 Computer Method Summary (Addendum) C -2R 8/28/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Zone I HVAC Split System" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Zone I HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C -21R) - Verify Thermal Mass: 840 sqft Covered Slab Floor, 3.50" thick at Mbr-Br2-Br3-Laun-Powd-Hall HIGH MASS Design(see C -21R) - Verify Thermal Mass: 757 sqft Exposed Slab Floor, 3.50" thick at Mbr-Br2-Br3-Laun-Powd-Hall The HVAC System "Zone II HVAC Split System" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Zone II HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 764 sqft Covered Slab Floor, 3.50" thick at Ding. Kit. Livg. Den. Entry HIGH MASS Design(see C -2R) - Verify Thermal Mass: 936 sqft Exposed Slab Floor, 3.50" thick at Ding. Kit. Livg. Den. Entry The HVAC System "Zone III HVAC Split System" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas The HVAC System "Zone III HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manua. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 298 sqft Covered Slab Floor, 3.50" thick at Guest Suite HIGH MASS Design(see C -21R) - Verify Thermal Mass: 164 sqft Exposed Slab Floor, 3.50" thick at Guest Suite Plan Field HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field EneravPro 3.1 By EnergvSoft User Number: 5021 Job Number: 0821004 Paae:14 of 17 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAMEDATE Clive Clark New Residence Tradition CC 8/28/2004 YSTEM NAME FLOOR AREA Zone I HVAC Split System 1,597 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems Heating System Output per System 8 Total Output (Btuh) 8 Output (Btuh/sqft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfmisgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 69.4 of 69.4 of Outside Air `0 . 0 cfm 69.4 of 0,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 0,000 50.1 Latent 5,000 5,000 2.9 21.9 547.5 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 808 16,091 465 248 16,186 0 805 809 0 0 0 0 0 0 0 0 0 805 809 17,7001 465 17 804 1,200 1,200 York CZB036/P1DUB16V080-410A 25,506 4,736 80,000 0.75 411.4 0.0 Total Adjusted System Output25,506 4,736 80,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am !am Temperatures at Time of 132.0 OF Supply Fan Heating Coil 1200 cfm h Return Air Ducts `i 111.0 / 77.6 OF 76.6 / 62.9 OF 76.6 / 63.0 OF 56.7 / 55.5 OF r . ,- Outside Airt 0 cfm Supply Fan Cooling Coil 1200 cfm 76.6162.9 OF of h Return Air Ducts 4 Supply Air Ducts 131.4 OF ROOMS 70.0 OF Supply Air Ducts 57.3 / 55.8 of 47.9% R.H. ROOMS 76.0 / 62.7 OF EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page: 15 of 17 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Clive Clark New Residence Tradition CC 8/28/2004 �1�� FLOOR AREA Zone II HVAC S lit S stem 1 700 Number of Systems I 11 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 47.1 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 20.6 Total Output (sgft/Ton) 582.9 COIL COOLING PEAK 11COILHTG.PEAK CFM I Sensiblel Latent I I CFM I Sensible 892 17,498 790 248 16,221 at Time of Cooling 0 11.0 / 77.6 OF Airflow (cfm) 875 811 0 0 0 0 0 0 0 0.71 0 Supply Fan Cooling Coil 0 875 811 19,248 790 17 843 CFM per System 1,200 ;DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 11.0 / 77.6 OF Airflow (cfm) 56.9 / 55.8 of 1,200 York CZ6036/P1DUB16V080410A 25,290 5,068 Supply Air Ducts 80,000 Airflow (cfm/sgft) 0.71 0 cfm Supply Fan Cooling Coil 57.6 56.0 of 1200 cfm Airflow (cfm/Ton) ROOMS 411.4 48.6% R.H. 0 76.0 / 62.9 of 76.7/63.1 F Total Adjusted System Output25,290 I Outside Air (%) o.o (Adjusted for Peak Design Conditions) 5,068 80,000 Outside Air (cfm/sgft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) 26.0 of 69.4 OF 69.4 of 132.00F Outside Air 0 cfm Supply Fan Heating Coil 1200 cfm 69.4 of Supply Air Ducts 131.4 of ROOMS 70.0 OF I EnerdyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page:16 of 17 Return Air Ducts `5 ;DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 11.0 / 77.6 OF 76.7 / 63.10F 76.7 / 63.2 of 56.9 / 55.8 of Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 57.6 56.0 of 1200 cfm ROOMS 48.6% R.H. 0 76.0 / 62.9 of 76.7/63.1 F I Return Air Ducts EnerdyPro 3.1 By EnergySoft User Number: 5021 Job Number: 0821004 Page:16 of 17 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Clive Clark New Residence Tradition CC 8/28/2004 YSTEM NAME FLOOR AREA Zone III HVAC Split System 462 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Stuh/sgft) 138.5 Cooling System Output per System 22,800 Total Output (Btuh) 22,800 Total Output (Tons) 1.9 Total Output (Btuh/sqft) 49.4 Total Output (sgft/Ton) 243.2 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.73 Airflow (cfm/Ton) 421.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above (EATING SYSTE 26.0 OF Outside Air, 0 cfm 69.6 of i at ARI conditions SYCHROMETRICS 69.6 of 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensiblel Latent I I CFM I Sensible 256 4,997 215 95 7,478 0 250 374 0 0 0 0 0 0 0 0 0 250 374 5.49T7--2115 8 225 York CZB024/PIDUA12VO64-410A 16,115 3,673 64,000 Total Adjusted System Output 16,115 3,673 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 am 144.7 of Supply Fan Heating Coil 800 cfm Time of Heatin Supply Air Ducts 144.3 of ROOMS 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 76.3/63.2OF 76.3/63.2OF 57.4/56.3OF 0 Supply Air Outside Air Ducts 0 cfm Supply Fan Cooling Coil 57.7 / 56.4 of 800 cfm 49.2% R.H. ROOMS 76.3/63.2 of 76.0/63.1OF `Return Air Ducts I EneravPro 3.1 By EneravSoft User Number: 5021 Job Number: 0821004 Pane: 17 of 17 1 y 11 w. • 0.- 1 HVAC Equipment Schedule (York or equal) Zone I & II AC -1 & II; York CZB036 condenser, 3.0 ton nominal, 13.2 SEER, R -410A refrigerant, 208-230/1/60 volts, 22.3 MCA, 35 amps MOCP, 190 lbs op wt. Sensible capacity @ 111° DB, outdoor design: 25,492btuh. Sensible load @ 76 DB; 670 WB, indoor design: 16,476btuh. FAU-1 & II; York P1 DUB16VO80-410A upflow, hi -low fire, variable speed furnace w/evaporator coil Model G1 FA036S14 and TXV, 3 ton nominal cooling. 100mbh input, 80mbh output heating cap. @ high fire, 80% AFUE, 1200 cfm @ .5"wc, 120/1/60,128 lbs op wt. Zone III AC -3; York CZB024 condenser, 2.0 ton nominal, 13.5 SEER, R -410A refrigerant, 208-230/1/60 volts, 16.5 MCA, 25 amps MOCP, 170 lbs op wt. Sensible capacity a@ 1110 DB, outdoor design: 14,073btuh. Sensible load.@ 76 DB; 670 WB, indoor design: 5.194btuh. FAU-3; York P1 DUA12VO64-410A upflow, hi -low fire, variable speed furnace w/evaporator coil Model G1 FA024S14 and TXV, 2 ton nominal cooling, 80mbh input, 64mbh output heating cap. @ high • fire, 80% AFUE, 875 cfm @ .5"wc, 120/l/60,117 lbs op wt. All Zones Wall Thermostats — Honeywell Model T8001 F1004 electronic programmable, 2 stage cooling/2 stage heating with dual setback feature. (or equal) Clark/Deacon Dr. Equip Sched_08.22.2004 0