Loading...
05-0684 (RC) Title 24TITLE 24 REPORT I Title 24 Report for: Barry Parkins DDS Building 78-080 Avenida La Fonda. La Quints, CA 92253 Project Designer: Robert H. Ricciardi AIA & Associates 75-090 St. Charles Place Suite A Palm Desert, CA 92211 760-346-2223 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 Job Number: Date: 4/25/2005 CITY OF LA OUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONST gy - • . e EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is khorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. .w EnergyPro 3.1 . By EnergySoft Job Number: User Number: 5862 0 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -MM Envelope Mandatory Measures Form LTG -4 Tailored LPD Summary and Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room Load Summary 1 1 2 3 14 15 16 17 19 23 7--E.ergyPr, 3.1 By EnergySoft Job Number: _ User Number: 5862 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE FROJECT Barry Parkins DDS Building DATE OF PLANS 4/25/2005 ROJECT ADDRESS BUILDING CONDITIONED FLOOR AREA 3,141 Sq.Ft. CLIMATE ZONE 15 78-080 Avenida La Fonda La Quinta for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this NONRESIDENTIAL PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # Robert H. Ricciardi AIA & Associates 760-346-2223 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section DOCUMENTATION AUTHOR TELEPHONE Checked by/Date G.R. Rose CAD Design (760) 345-4859 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR DATE OF PLANS DATE Gina Rose BUILDING CONDITIONED FLOOR AREA 3,141 Sq.Ft. CLIMATE ZONE 15 BUILDING TYPE for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to NEW CONSTRUCTION ADDITION ❑ ALTERATION F—] EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR SIGNATU DATE Gina Rose Z 6S-- The Principal Designers hereby certify that the proposed ing design represented in the construction documents andmocj4lled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. F1 ❑ F] 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE Robert H. Ricciardi AIA & Associates LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms LTG -1 PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1, MECH-2, MECH-3 Required Forms INCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE lEnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:3 of 26 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PERF -1 Barry Parkins DDS Building DATE 4/25/2005 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard ENERGY COMPONENT Design Space Heating 5.83 Space Cooling 58.55 Indoor Fans 0.00 Heat Rejection 0.00 Pumps & Misc. 0.00 Domestic Hot Water 0.00 Lighting 35.34 Receptacle 19.96 Process 0.00 TOTALS: 119.68 Percent better than Standard: Proposed Compliance Design Margin 2.96 2.87 43.27 15.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 35.34 19.96 0.00 0.00 0.00 101.53 18.15 15.2% ( 15.2% excluding [® Standard -Proposed I ",M ,I - D"" ` 1 ; 0 10 20 30 40 50 kBtu/sgft•yr process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones west 270 deg Conditioned Floor Area 3,14sqft. Unconditioned Floor Area o sqft. Conditioned Footprint Area 3,14 sqft. 1 5 4 Orientation Front Elevation (West) Left Elevation (North) Rear Elevation (East) Right Elevation (South) Total 1 Roof Gross Area sqft. sqft. sqft. sqft. sqft. 177777128 sqft. Glazing Area Glazing sqft. sqft. sqft. sqft. sqft. sqft. Ratio 594 83 14.0% 504 45 8.9% 594 0 0.0% 495 0.0% 2,1871 _A 5.8% 3,141 E� 0.0% Standard Proposed Lighting Power Density 1.200 Wisgft. 1.200 Wisgft. Prescriptive Env. Heat Loss 1,015 Btu/h 456 Btuih Prescriptive Env. Heat Gain 73,216 Btu/h-F 38,508 Btuih-F LEEDTM Ener 8 Atmos here Credit_ Savings vs. Title 24 18.20% Energy Performance Credit2 3 Points 1. excludes process and receptacle 2. see LEED table 8a or 8-0 Remarks: Standard Building (Compliance) Run Initiation Time: 04/25/05 17:30:23 Run Code: 1114468223 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page 4 of 26 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 ROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft 1 Inst. WI D ( f)1 Port. LPD (Wlsf)1 Ctrl. Tailored Credits LPD (Wlsf)2 (W/sf) 3 Proc. Loads (W/sf) 3 Ton Unit Zone 1 Comp Bldg Medical 598 '1.200 4 Ton Unit Zone 2 Comp Bldg Medical 828 '1.200 5 Ton Units Zone 3 Comp Bldg Medical 1,035 "1.200 3 Ton Unit Zone 4 Comp Bldg Medical 680 "1.200 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation �GnvE-r I IVIVAL. l,V1YLJ111V110 \+VIVWLIAM r- VrIr-%A\LIJ I The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. lothorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:5 of 26 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 NAME Barry Parkins DDS Buildin DATE 4/25/2005 OPAQUE SURFACES Area U -Fac. Act. Azm. SHGC Glazing Type Location I Comments Window 18 0.780 270 0.55 Surface Framing # Type Type Act. Area U -Fac. Azm. Tilt Solar Gains Y/N Form 3 Reference Location I Comments 1 Roof Wood 598 0.035 0 0 X11 I R-30 Roof R.30.2x12.16 Zone 1 2 Wall None 117 0.129 90 90 X11 I R-13 Batt w/7" Conrcrete 2x4 Metl. Zone 1 3 Wall None 414 0.129 180 90 X I I R-13 Batt w!7" Conrcrete 2x4 Metl. Zone 1 4 Wall None 64 0.129 270 90 R-13 Batt w/7" Conrcrete, 2x4 Metl. Zone 1 5 Door None 18 0.387 270 90 X Solid Wood Door Zone 1 6 Roof Wood 828 0.035 0 0 X R-30 Roof R.30.2x12.16 Zone 2 7 Wall None 63 0.129 0 1 90 R-13 Batt w/7" Conrcrete, 2x4 Metl. Zone 2 8 lDoor None 45 0.387 0 90 X Solid Wood Door Zone 2 9 lWall None 477 0.129 90 90 R-13 Batt w/7" Conrcrete, 2x4 Metl. Zone 2 10 Roof Wood 1,035 0.035 0 0 X11 I R-30 Roof R.30.2x12.16 Zone 3 11 Wall None 81 0.129 0 90 AL I R-13 Batt w/T' Conrcrete, 2x4 Metl. Zone 3 12 Wall None 81 0.129 180 90 X11 I R-13 Batt w/T' Conrcrete, 2x4 Metl. Zone 3 13 Wall None 202 0.129 270 90 R-13 Batt w/7" Conrcrete, 2x4 Metl. Zone 3 14 Door None 38 0.387 270 90 X Solid Wood Door Zone 3 15 Roof Wood 680 0.035 0 0 R-30 Roof R.30.2x12.16 Zone 4 16 lWall None 225 0.129 0 90 X R-13 Batt w/7" Conrcrete, 2x4 Metl. Zone 4 17 IDoor None 45 0.387 0 90 X Solid Wood Door Zone 4 18 Wall None 189 0.129 270 1 90 R-13 Batt w/7" Conrcrete, 2x4 Metl. Zone 4 FENESTRATION SURFACES Site Assembled Glazing U %A]CUR uux n Dummy is iuu,uuu sqn or crH ana — 1u,uuu sqtt vertical glazing then NFRC Certification is required. Fniinw NFP(: inn -RR Prn—rlrnroc nnA m 1....0 AICDr" I k. r # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location I Comments Window 18 0.780 270 0.55 Double Metal Tinted Zone 1 Window 18 0.780 270 0.55 Double Metal Tinted Zone 1 3 Window 24 0.780 270 0.55 Double Metal Tinted Zone 3 4 Window 24 0.780 270 0.55 Double Metal Tinted Zone 3 5 Window 45 0.780 0 0.55 1 Double Metal Tinted Zone 4 EXTERIOR SHADING ## Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. H t. Right Fin Dist. Len. Hat. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 5 None 0.76 Run Initiation T' e• 04/25/05 :30 3 Run Coe: 1114468223 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:6 of 26 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 ECT NAME Barry Parkins DDS Buildi DATE 4/25/2005 I eMDQ I cwi i wcra II 1 iiminnirc - Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp v DESCRIPTION # (Lamp + Ballastl Total Watts # Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 4Meets Total F-1Efficacyand Control Requirement of 0130(c) Portable Lighting (From LTG -1) F-1 Control Requirements of §131(f) Less Control Credit Watts (From LTG -3) Adjusted Actual Watts 0 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 ECT NAME DATE W- Barry Parkins DDS Building 1 4/25/2005 1 0 M I ROOM # DEFAULT AREA OR ZONE ID W/s ftSF TOTAL WATTS B X C TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL FA] a 0 0 0 0 LUMIN. TASK # OF TOTAL TOTAL TOTAL 0 0 TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL FA] a 0 0 0 0 LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Description FIXT. FIXTURE (SF) AREAS (D x E) (C x E) TOTAL ROOM # TOTAL AREA OR ZONE ID (SF) Designer needs to provide detailed documentation that the ligl level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 1 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 0 0 Run Initiation Time: 04/25/05 17:30:23 Run Code: 1114468223 EnergyPro 3.1 By Energysoft User Number: 5862 Job Number: Page:8 of 26 CERTIFICATE OF COMPLIANCE Performance MECH-1 r OJECT NAME DATE Barry Parkins DDS Building4/25/2005 SYSTEM FEATURES SYSTEM NAME 4 TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I EATING EQUIPMENT TYPE EATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Temp n/a Air Balance Auto No Economizer 90 cfm Heat Pum 6.90 HSPF Packaged DX 10.2 SEER / 9.2 EER 3 TON UNIT Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Temp n/a Air Balance Auto No Economizer 124 cfm Heat Pum 6.90 HSPF Packaged DX 10.7 SEER / 9.5 EER 4 Ton Unit Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Require n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Temp n/a Air Balance Auto No Economizer 155 cfm Heat Pum 7.00 HSPF Packaged DX 10.0 SEER / 9.0 EER 5 TON UNITS Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS. HEAT / COOL? Y: Yes M: Manual Timer 0: Other C: Curve N: No ntAi AND cuuL SUPPLY RESt1-r VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE ")TFS Tn FIFI Il _ Fnr Rnilrlinn rinnnr#mnn♦ I Ice r%niss Run Initiation Time: 04/25/05 17:30:23 Run Code: 1114468223 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:9 of 26 4 CERTIFICATE OF COMPLIANCE Performance MECH-1 NAME Parkins DDS Buildin SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I EATING EQUIPMENT TYPE EATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE Programmable Switch Heating 8 Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Temp n/a Air Balance I Auto No Economizer 102 cfm Heat Pum 6.90 HSPF Packaged DX 10.2 SEER / 9.2 EER 3 TON UNIT Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No DATE 4/25/2005 NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD 0: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/ COOL? Y: Yes HEAT AND COOL SUPPLY RESET? N: NO VENTILATIONOUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144e3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE 1 Ise r% .I - (1TFS T[) FIFI r) - Fnr Rnilrlinn nnnnrimnn4 Run Initiation Time: 04/25/05 17:30:23 Run Code: 1114468223 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 10 of 26 CENTRAL SYSTEM FAN SUMMARY MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 INICHILLER AND TOWER SUMMARY RETURN FAN System Name Fan Type Motor Location CFM BHP Efficiency Tons PUMPS BHPEff. Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 2,000 0.00 40.0% 100.0% 4 Ton Unit Constant Volume Draw -Through 1,600 0.00 40.0% 97.0% 2,000 0.00 40.0% 100.0% 5 TON UNITS Constant Volume Draw -Through 2,000 0.00 40.0% 97.0% 2,000 0.00 40.0% 100.0% BOILER SUMMARY TANK INSUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R -Val. CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty. Output Aux. kW Eff. Output Sensible Efficiency Economizer Type 3 TON UNIT Packaged DX 2 35,000 0.0 6.90 HSPF 36,600 25,62010.2 SEER / 9.2 EER No Economizer 4 Ton Unit Packaged DX 1 47,000 0.0 6.90 HSPF 48,500 33,95010.7 SEER / 9.5 EER No Economizer TON UNITS WO—N UNITS Packaged DX 2 60,000 0.0 7.00 HSPF 56,000 44,66010.0 SEER/ 9.0 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHPEff. Motor Drive Eff. 3 TON UNIT Constant Volume Draw -Through 1,200 0.00 40.2% 98.0% 2,000 0.00 40.0% 100.0% 4 Ton Unit Constant Volume Draw -Through 1,600 0.00 40.0% 97.0% 2,000 0.00 40.0% 100.0% 5 TON UNITS Constant Volume Draw -Through 2,000 0.00 40.0% 97.0% 2,000 0.00 40.0% 100.0% .ten. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:11 of 26 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 1 �ROJECT NAME Barry Parkins DDS Buildina DATEa1i-17nn-r; TERMINAL in. CFM Motor Drive Room Name Qtv, I CFM I BHP Eff. Eff. TERMINAL FAN Motor Drive CFM BHP Eff. Eff. E RAUSTFAN Room Name Qty. CFM BHP Motor Eff. Drive I Eff. i L:� Output EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:12 of 26 MECHANICAL VENTILATION MECH-3 ROJECT NAME DATE Barry Parkins DDS Building 4/25/2005 --] MECHANICAL VENTILATION a ©© a a n n n n n n ZONE/SYSTEM Zone 1 3 Ton Unit Zone 2 4 Ton Unit Zone 3 5 Ton Units Zone 4 3 Ton Unit AREA BASIS DESIGN OUTDOOR AIR CFM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) 598 0.15 90 90 828 0.15 124 E90 124 1,035 0.15 155 155 155 680 0.15 102 1021 102 102 102 OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (ExF) Total Total Total Total REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS. FER AIR 90 90 90 124 124 E90 124 124 155 155 155 155 1021 102 102 102 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdocr Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 13 of 26 1 4 �4 ENVELOPE MANDATORY MEASURES ENV -MM OJECT NAME DATE Barry Parkins DDS Building 4/25/2005 DESCRIPTION Designer Enforcement a§ 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3: X❑ §118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. X❑ § 116(b) Site Constructed Doors, Windows and Skylights'shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). XI § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. §118(e) Demising Walls in Nonresidential Buildings: ,The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 14 of 26 TAILORED LPD SUMMARY and WORKSHEET Part 1 Of 3 LTGA tOJECT NAME DATE Barry Parkins DDS Building I 4/25/2005 1. Watts for Illuminance Categories A -D (from column G) 3 110 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) > 0 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) 01+ 1 0 + I - 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) > 3 110 watts TAILORED LPD - Illuminance Categories A B C and D and Gross Sales Area a © © a a o ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD . ALLOWED WATTS (E x F) zone 1 Health Care—Dental - General D 0.00 598 0.99 592 Zone 2 Health Care—Dental - General D 0.00 828 0.99 820 Zone 3 Health Care—Dental - General D 0.00 1,035 0.99 1,025 zone 4 ::: 7 Health Care—Dental -General D 0.00 680 0.99 673 . BUILDING PAGE TOTAL TOTAL 3,1 3,1101 — > 3 141 3,1101 > SF WATTS EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 15 of 26 LIGHTING MANDATORY MEASURES LTG -MM iffOJECT NAME — DATE Barry Parkins DDS Building 4/25/2005 4 lr DESCRIPTION Designer Enforcement FXJ § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic ` control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. n § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X❑ § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. ❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. 0 § 131(,) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. FX § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting: Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 16 of 26 4 4 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM ECT NAME DATE Barry Parkins DDS Building I 4/25/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. 0 § 115(a) Fan type central furnaces shall not have a pilot light. n§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or IF]§ 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:17 of 26 4 4 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM ECT NAME Barry Parkins DDS Buildin DATE 4/25/2005 Description Designer Enforcement Ventilation ❑X § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. X] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or FXJ § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the .person with overall responsibility for the design of the ventilation system; or ,❑ § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(04 Another method approved by the Commission. Service Water Heating Systems X] § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. v X] § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 18 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 STEM NAME 3 Ton Unit FLOOR AREA 598 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL CFM Sensible Latent CFM Total Room Loads 827 13,575 1,196 603 Return Vented Lighting 0 Return Air Ducts 679 Return Fan 0 Ventilation 90 3,604 1,224 90 Supply Fan 0 Supply Air DUCtS 679 TOTAL SYSTEM LOAD 1 18,536 21420 HTG. PEAK Heating System Sensible Output per System 35,000. 9,006 Total Output (Btuh) 35,000 Output(Btuh/sgft) 58.5 450 Cooling System 0 Output per System 36,600 4,198 Total Output (Btuh) 36,600 0 Total Output (Tons) 3.0 450 Total Output (Btuh/sgft) 61.2 14,104 Total Output (sgft/Ton) 196.1 Air System HVAC EQUIPMENT SELECTION CFM per System 1,200 3 TON UNIT 24,650 7,505 23,019 Airflow (cfm) 1,200 Airflow (cfm/sgft) 2.01 Airflow (cfm/Ton) 393.4 Outside Air (%) 7 5 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 24,650 7,505 Aug 3 pm 23,019 Outside Air (cfm/sgft) 0.15 Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of Outside Air 90 cfm 69.6 of Return Fan • 66.4 of 84.3 of 84.3 of • O Heating Coil Supply Fan 1200 cfm 69.6 of Return Air Ducts 2000 cfm Supply Air Ducts 83.9 of ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.7 OF 310 Outside Air 90 cfm 4.5 ! 63.2 F 77.3/64.3 OF 58.2/57.0 OF 58.2/57.0 OF .01O Supply Air Ducts Cooling Coil Supply Fan 58.7 / 57.2 of 1200 cfm 54.7% R.H. ROOMS Return Fan 74.5 / 63.2 OF 74.0 63.0 of I OReturn Air Ducts • 2000 cfm EnergyPro 3.1 By Energysoft User Number: 5862 Job Number: Page 19 of 26 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 STEM NAME 4 Ton Unit FLOOR AREA 828 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM I Sensible Latent CFM I Sensible Output per System 47,000 Total Room Loads 826 13,419 1,656 1 527 7,996 Total Output (Btuh) 47,000 Return Vented Lighting 0 Output (Btuh/sgft) 56.81 Return Air Ducts 671 400 Cooling System Return Fan 0 0 Output per System 48,500 Ventilation 124 5,007 1,62 124 5,828 Total Output (Btuh) 48,500 Supply Fan 0 0 Total Output (Tons) 4.0 Supply Air Ducts 671 400 Total Output (Btuh/sgft) 58.6 TOTAL SYSTEM LOAD 19,776 3,277 14,623 Total Output (sgft/Ton) 204.9 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 4 Ton Unit 32,348 10,381 30,911 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.93 Airflow (cfm/Ton) 395.9 Total Adjusted System Output32,348 (Adjusted for Peak Design Conditions) 10,381 30,911 Outside Air (°i°) 7 8 Outside Air (cfm/sgft) 0.15 TIME OF SYSTEM PEAK Jul 37 Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF Outside Air 66.4 OF 84.4 OF 84.4 OF O Supply Air Ducts 124 cfm Heating Coil Supply Fan ` 1600 cfm 84.2 °F ROOMS 69.8 OF Return Fan e O 69.8 OF Return Air Ducts 70.0 OF I 2000 cfm DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0 / 77.7 OF Outside Air 77.3 / 64.5 OF 58.5 / 57.3 OF 58.5 / 57.3 OF 0 Supply Air Ducts 124 cfm Cooling Coil Supply Fan 58.8 / 57.5 OF 1600 cfm 55.3% R.H. ROOMS Ibie- 0 4.4 / 63.3 F ;0 Return Fan O 74.4 / 63.3 OF Return Air Ducts 74.0 / 63.2 °F I 2000 cfm EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 20 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Barry Parkins DDS Building 4/25/2005 STEM NAME FLOOR AREA 5 Ton Units 1,035 ;NGINEERI Number of Output per S Total Output Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sgft/ron) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) IOutside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions M 60,000 Total Room Loads 120,000 Return Vented Lighting 115.9 Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM 56,000 112,000 9.3 108.2 110.9 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible Supply Air Ducts Outside Air 946 19,842 2,070 461 8,167 0 Heating Coil 992 408 0 0 155 6,116 3,256 155 7,308 70.0 OF 0 0 9921 408 27,942 5,326 16,292 c,vuv 4,000 5 TON UNITS 92,041 2,413 78,921 3.86 428.6 3 9 Total Adjusted System Output g2 041 2,413 78,921 (Adjusted for Peak Design Conditions) 0.15 TIME OF SYSTEM PEAK Jul 4 pm Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 68.2 of 86.6 OF 86.6 OF Supply Air Ducts Outside Air © 155 cfm 86.5 °F Heating Coil Supply Fan 4000 cfm ROOMS 69.9 OF Return Fan 69.9 OF 70.0 OF Return Air Ducts � I O 4000 cfm DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.4 OF 75.7 / 61.4 °F 54.2 / 53.0 OF 54.2 / 53.0 OF ` Outside Air O Supply Air Ducts 155 cfm Cooling Coil Supply Fan 54.4 / 53.1 OF 4000 cfm ROOMS 46.3% R.H. 4.2/60.7 °F Return Fan74.0 74.2 / 60.7 °F / 60.7 OF O Return Air Ducts I 4000 cfm EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:21 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Barry Parkins DDS Building 4/25/2005 STEM NAME FLOOR AREA ' 3 Ton Unit 680 Number of Output per System Total Output (Btuh) Output (Btuh/sgft) oling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) fOutside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions IEATING SYSTEM PSYCHROMETRICS 26.0 of 66.0 of Outside Air 102 cfm 69.7 of 112.0 / 77.7 of 311� Outside Air 102 cfm 5/63.4 of 5,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 5,000 51.5 Latent 6,600 6,600 3.0 53.8 223.0 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 18,570 2,666 13,793 1,200 1,200 3 TON UNIT 24,621 7,738 23,019 1.76 393.4 8 5 Total Adjusted System Output 24,621 7,738 23,019 (Adjusted for Peak Design Conditions) 0.15 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Heating Coil Return Fan �2000m im I emperatures at lime 83.9 of 0 Supply Fan 1200 cfm 69.7 of 83.9 of -� Supply Air Ducts 83.5 of ROOMS 70.0 of h Return Air Ducts 4 77.7 / 64.7 of M 58.6 / 57.4 of Cooling Coil Return Fan 74.5 / 63.4 of Supply Fa 1200 cfm 58.6 / 57.4 of Supply Air Ducts Fan Cool 59.1 / 57.6 of 55.6% R.H. ROOMS 74.0 / 63.2 of h Return Air Ducts 4 2000 cfm EnergyPro 1.1 By EnergySoft User Number: 5862 Job Number: Page: 22 of 26 ROOM LOAD SUMMARY ml PROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 STEM NAME 3 Ton Unit FLOOR AREA 598 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 827 13,575 1,196 827 13,575 1,196 603 9,006 PAGE TOTAL 1 827 13,575 1,196 603 9,006 TOTAL 1 827 13,575 1,196 603 9,006 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:23 of 26 ROOM LOAD SUMMARY PROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 STEM NAME 4 Ton Unit FLOOR AREA 828 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 - 1 831 13,493 1,656 826 13,419 1,656 527 7,996 PAGE TOTAL 826 13,419 1,656 TOTAL 826 13,419 1,656 527 7,996 527 7,996 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:24 of 26 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:25 of 26 PROJECT NAME Barry Parkins DDS Building DATE 4/25/2005 STEM NAME 5 Ton Units FLOOR AREA 1,035 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Zone 3 1 946 19,842 2,070 946 19,842 2,070 461 8,167 PAGE TOTAL 1 946 1x,842 2,070 461 8,167 TOTAL 1 946 19,842 2,0701=4611 8,167 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:25 of 26 ROOM LOAD SUMMARY PROJECT NAME DATE Barry Parkins DDS Buildinq 4/25/2005 7 STEM NAME FLOOR AREA 3 Ton Unit 680 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 4 Zone 4 1 822 13,155 1,360 822 13,155 1,360 565 8,197 PAGE TOTAL 1 822 13,155 1,360 565 8,197 TOTAL 1 822 13,155 1,360 565 8,197 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:26 of 2671