13-1390 (AR) Title 24 Revision 1BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Ave La Fonda
78550 Ave La Fonda
La Quinta, CA 92253
Project Designer:
. Sipovac Construction Inc.
72-651 Theodora Lane
Palm Desert, CA 92260
760-360-9700
Report Prepared by:
Bob Sipovac
Sipovac Construction
72-651 Theodora Lane
Palm Desert, CA 92260
760-360-9700
RECEIVED
JUN 2 6 2014
CITY OF LA QUINTA
CoAtLfi&JEe ELOPMENT
090513 CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
Date: APPROVED
6/20/2014 FOR CONSTR CTION
{ DATE 11-1jFS BY
The EnergyPro computer program has been used to perform the calculations summarized'in this'compliance°report= Fara�kias.a I roval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Buildiq Energy Efficiency Standards.
User
This program developed by EnergySoft, LLC — www.energysoft.com.
FR( Ca,I i
TABLE OF CONTENTS
Cover Page •
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
f APPROVED
i FOR CONSTRUCTION
' DATE BY
EnergyPro 5.1 by EnergySoft Job Number: ID"090513 &Nm—mber. 5289
1
2
3
10
13
15
17
19
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Ave La Fonda
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
6/20/2014
Project Address
78550 Ave La Fonda La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,797
Addition
1,175
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Wall Wood Framed R-11 640 Existing
Door Opaque Door None 20 Existing
Wall Wood Framed R-13 190 New
Slab Unheated Slab -on -Grade None 1,540 Perim = 0' Existing
Roof Wood Framed Attic R-19 1,324 Existing
Slab Unheated Slab -on -Grade None 1,257 Perim = 0' New
Roof Wood Framed Attic R-30 82 New
Wall Wood Framed R-19 749 New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Front (S) 62.3 0.770 0.73 none none Bug Screen Removed
Front (S) 45.0 0.390 0.37 none none Bug Screen New
Left (Vv) 76.1 0.770 0.73 none none Bug Screen Removed
Left (Vig 230.8 0.390 0.37 none none Bug Screen New
Rear (N) 114.6 0.770 0.73 none none Bug Screen Removed
Right (E) 19.5 0.770 0.73 none none Bug Screen Removed
Right (E) 19.5 0.390 0.37 none none Bug Screen New
Skylight 14.3 0.390 0.30 none none None New
Rear (N) 16.1 0.390 0.37 none none Bug Screen New
Skylight 9.0 0.550 0.67 none none None New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Electric 3.50 HSPF
Split Air Conditioner 13.0 SEER Setback Existing
1 Electric 3.50 HSPF
Split Air Conditioner 13.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
New 4 tons Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
',ITV nF: 1 A 61 —_,rl I
WATER HEATING v " *-
BUILDING & SAFETY DEPT.
Ot . Type Gallons Min. Eff �� jPistributioStatus
1 Instant Gas 0
0.94 ItIKitchen Pipe Ins I New
I A lP
EnergyPro 5.1 by EnergySoft User Number: 5289
RunCode: 201406-20T11:43:13 /D7090513
Page 3 of 20
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Ave La Fonda
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
6/20/2014
Project Address
78550 Ave La Fonda La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,797
Addition
1,175
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Rafter
R-38 1,166 New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC overhang Sidefins Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
N CITY nf= I AR A� 6
WATER HEATING BUILDING & SAFETY DEPT.
Qty. Type Gallons Min. Eff ,N lQistribution,,.._ Status
FQFP r'g.TP
.0hl1v -� sr+q
- " � � t 1 1
:DATE
BY
L
EnergyPro 5.1 by EnergySoft User Number. 5289 RunCode. 2014 06-20T11:43:13 ID: 090513
Page 4 of 20
PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF-1 R
Project Name
Ave La Fonda
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
1612012014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
CITY C)F LA OUINTA
BUILDING & SAFETY DEPT.
FOR CONS RI j ,Tlnn
EnemyPro 5.1 by EnemySoft User Number.- 5289 R RunCEde: 2014-0&20T1$'if3--J3 ID: 090513 Page 5 of 20
J
PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R
Project Name
Building Type 0 Single Family ❑ Addition Alone
Date
Ave La Fonda
❑ Multi Family m Existing+ Addition/Alteration
6/20/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 6.03 4.00 2.04
Space Cooling 93.86 93.55 0.31
Fans 19.73 20.22 -0.49
Domestic Hot Water 20.77 15.21 5.56
Pumps 0.00 0.00 0.00
Totals 140.39 132.98 7.41
Percent Better Than Standard: 5.3%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S)180 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 559 45
Fuel Available at Site: =lectric (No Natural Gas Available (lM 562 231
Raised Floor Area: 0 (N) 470 16
Slab on Grade Area: 2.797 (E) 321 20
Average Ceiling Height: 8.8 Roof 2,596 23
Fenestration Average U -Factor: 0.39 TOTAL: 335
Average SHGC: 0.37 Fenestration/CFA Ratio: 12.0%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Sipovac Construction
6/10/2014
Address 72-651 Theodora Lane Name Bob Sipovac
City/State/ZipCity/State/Zip Palm Desert CA 92260 Phone 760-360-9700 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verifie�ation by=an approved=HERS ra e
I �' ' OF �� I Iil`�A
Designer or Owner (per Business & Prof_essQns,,Code)aAFETY DEPT.
Company Sipovac Construction Inc.
®VE
rr
72-651 Theodora Lane � '
Address Nang Bob COMSTRUCTION
City/State/Zip Palm Desert, CA 92260 Phone 760-360-9700 Sign License # Date
H I L----- BY
Ene Pro 5.1 by EnemySoft User Number: 5289 RunCode: 2014- 513 Page 6 of 20
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF-1 R
Project Name
Ave La Fonda
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family Ga Existing+ Addition/Alteration
Date
6/20/2014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall
167
0.110 R-11
180 90 Existing 4.3.1-A2
Existing House
Door
20
0.500 None
180 90 4.5.1-A4
Existing House
Wall
68
0.110 R-11
'Existing
90 90 Existing 4.3.1-A2
Existing House
Wall
219
0.110 R-11
180 90 Existing 4.3.1-A2
Existing House
Wall
51
0.102 R-13
180 90 New 4.3.1-A3
Existing House
Wall
93
0.110 R-11
270 90 Removec 4.3.1-A2
Existing House
Wall
93
0.102 R-13
270 90 New 4.3.1-A3
Existing House
Wall
47
0.102 R-13
0 90 New 4.3.1-A3
Existing House
Wall
35
0.110,R-11
01 90 Remove 4.3.1-A2
Existing House
Wall
73
0.110 R-11
270 90 Removec 4.3.1-A2
Existing House
Wall
81
0.110 R-11
180 90 Removec 4.3.1-A2
Existing House
Wall
88
0.110 R-11
0 90 Removec 4.3.1-A2
Existing House
Wall
57
0.110 R-11
0 90 Removec 4.3.1-A2
Existing House
Wall
187
0.110 R-11
90 90,Existing 4.3.1-A2
Existing House
Slab
1 1,5401
0.730 None
01 180 1 Existing 4.4.7-A1
lExisting House
Roof
1 1,3241
0.049 R-19 1
11
1 01 0 1 Existing 4.2.1-A4
Existing House
FENESTRATION SURFACE DETAILS
ID
Type
Area U-Factor
SHGC2
Azm Status Glazing Type
Location/Comments
1
Window
19.5 0.770 Default
0.73 Default
180 Removed Double Metal Clear
Existing House
2
Window
19.5 0.390 NFRC
0.37 NFRC
180 New Milgard Classic Low-E Vinyl
Existing House
3
Window
8.5 0.770 Default
0.73 Default
180 Removed Double Metal Clear
Existing House
4
Window
8.5 0.390 NFRC
0.37 NFRC
180 New Milgard Classic Low-E Vinyl
Existing House
5
Window
8.5 0.770 Default
0.73 Default
180 Removed Double Metal Clear
Existing House
6
Window
8.5 0.390 NFRC
0.37 NFRC
180 New Milgard Classic Low-E Vinyl
Existing House
7
Window
8.5 0.770 Default
0.73 Default
180 Removed Double Metal Clear
Existing House
8
Window
8.5 0.390 NFRC
0.37 NFRC
180 New Milgard Classic Low-E Vinyl
Existing House
9
Window
19.5 0.770 Default
0.73 Default
270 Removed Double Metal Clear
Existing House
10
Window
19.5 0.390 NFRC
0.37 NFRC
270 New Milgard Classic Low-E Vinyl
Existing House
11
Window
62.7 0.770 Default
0.73 Default
0 Removed Double Metal Clear
Existing House
12
Window
13.3 0.770 Default
0.73 Default
270 Removed Double Metal Clear
Existing House
13
Window
43.3 0.770 Default
0.73 Default
270 Removed Double Metal Clear
Existing House
14
Window
17.3 0.770 Default
0.73 Default
180 Removed Double Metal Clear
Existing House
15
Window
17.3 0.770 Default
0.73 Default
0 Removed Double Metal Clear
Existing House
16
lWindow
17.3 0.770 Default
0.73 Default
0 Removed Double Metal Clear
Existing House
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC T 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hot FWd
Ove hanq Left Fin Ri ht Fin
Len H t LExt RExt Dist Len Hot Dist Len Hot
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
1Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
1
-- -
13
Bug Screen
0.76
I
l., a Y-
14
Bug Screen
0.76`-
I
t� tai r,i. _`, `' Ia i r'1
15
Bug Screen
0.76
)
16
Bug Screen
0.76
+ --V
L-
FOR CONSTRUCTION
EnergyPro
5.1 by EnergySoft User Number.- 5289 I Run Code: 201406-20TH:43:13 ID: 090113
Pa e 7 of 20
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF-1 R
Project Name
Ave La Fonda
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family [0 Existing+ Addition/Alteration
Date
1612012014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
202
0.049 R-19
0 0 Remove 4.2.1-A4
ExistingHouse
Slab
82
0.730 None
0 180 New 4.4.7-A1
ExistingHouse
Roof
82
0.031 R-30
0 0 New 4.2.1-A20
ExistingHouse
Wall
46
0.074 R-19
90 90 New 4.3.1-A5
New Living Area
Wall
406
0.074 R-19
0 90 New 4.3.1-A5
New Living Area
Wall
119
0.074 R-19
270 90 New 4.3.1-A5
New Living Area
Wall
58
0.074 R-19
180 90 New 4.3.1-A5
New Living Area
Wall
120
0.074 R-19
270 90 New 4.3.1-A5
New Living Area
Roof
1,166
0.028 R-38
0 0 New 4.2.2-A 19
New Living Area
Slab
1,175
0.730 None
0 180 New 4.4.7-A1
New Living Area
FENESTRATION SURFACE DETAILS
ID
Type
Area U-Factor SHGC
Azm Status Glazing Type
Location/Comments
17
Window
17.3 0.770 Default 0.73 Default
0 Removed Double Metal Clear
Existing House
18
Window
19.5 0.770 Default 0.73 Default
90 Removed Double Metal Clear
Existing House
19
Window
19.5 0.390 NFRC 0.37 NFRC
90 New Milgard Classic Low-E Vinyl
Existing House
20
Skylight
14.3 0.390 NFRC 0.30 NFRC
0 New Marvin Clad Casemaster Low E Existing House
21
Window
13.0 0.390 NFRC 0.37 NFRC
0 New Milgard Classic Low-E Vinyl
New Living Area
22
Window
3.1 0.390 NFRC_ 0.37 NFRC
0 New 1 Milgard Classic Low-E Vinyl
New Living Area
23
Window
41.3 0.390 NFRC 0.37 NFRC
270 New Milgard Classic Low-E Vinyl
New Living Area
24
Window
112.0 0.390 NFRC 0.37 NFRC
270 New Milgard Classic Low-E Vinyl
New Living Area
25
Window
29.0 0.390 NFRC 0.37 NFRC
270 New Milgard Classic Low-E Vinyl
New Living Area
26
Window
29.0 0.390 NFRC 0.37 NFRC
270 New Milgard Classic Low-E Vinyl
New Living Area
27
Skylight
9.0 0.550 Default 0.67 Default
0 New Double Non Metal Clear
New Living Area
(1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hat Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
None
1.00
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
_
27
None
1.00
E3(111
1
i
1 t'LJCT10N
EnergyPro
5.1 by EnergySoft User Number: 5289 1 Run Code. 2014_0.6-20T x13:13 ID: 090$13
Pa-e 8 of 20
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Ave La Fonda
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
6/20/2014
BUILDING ZONE INFORMATION
System Name
Floor Area
Zone Name New Existinq Altered Removed Volume
Year Built
HVAC System Existing House 1,622
12,976 1991
New 4 tons New Living Room + Bed Room 1,175
11,750
Totals 1,175 0 1,622 01
1
HVAC SYSTEMS
System Name Qty.
Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
HVAC System
1 Electric 3.50 HSPF Split Air Conditioner 13.0 SEER Setback
Existing
New 4 tons
1 Electric 3.50 HSPF Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
System Name
Duct
Heating Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0
❑
New
New 4 tons Ducted Ducted Attic, Ceiling Ins, vented 8.0
❑
New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A O Smith Water Products
1
Small Gas
Kitchen Pipe Ins
37,000
50
0.62
Na
Na
Removed
Rheem RTGH-84DVN
1
Instant Gas
I Kitchen Pipe Ins 1
157,0001
0
0.94
Na
Na
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
o
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
QtyTHP
Plenum Outside - -Buried-
i
I1, I M II A
r -0A
A .I1, e e
C.T I 11 Al e w n e-.
❑�
1-4 U I I'V
ep�tit—LTY
DEPT -
OP
J JON
EnergyPro 5.1 by EnefgySoft User Number: 5289 1 RunCode: 2014-06-20TH:43:13 ID: 091,1311 513
Pa e 9 of 20
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
Ave La Fonda
6/20/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall or equivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that -due to sunli ht moisture3 ui mentrnaintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant -suction lines,ihcludds a, v or is enclosed entirely in
Xp_6t
�r"eWrddnt
conditioned space. 1 PUILD 'QIP
150(j)4: Solar water -heating systems and/or collectors are certified -,by the-Solat,Ratin rauQ&-tehificition Corporation.
FOR CONS RUCTION
EnergyPro 5.1 by EnergySoft User Number: 5289 N Rgp ode: 2014-08-20TH:43:13 10: 010513 Page 10 of 20
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name Date
Ave La Fonda 6/20/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause de radation of the material.
150 m 10: Flexible ducts cannot have porous inner cores. .
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
Programmed to run only durina off-peak electric demand periods.
§150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). 1
Residential Lighting Measures:
§150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by 4150(k)2.
150 k 3: The watta a of permanently installed luminaires shall be determined as specified by 6130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 5150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 f12 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet. ; _ _ _ _
ui
mounNTA
BUILDING & SAFETY DEPT.
L��R®UED
RunCode: 2014-0&20TH:43:13 I
DATE BY J
EnergyPro 5.1 by EnergySoft User Number: 5289 /D: 090513 Page 11 of 20
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Ave La Fonda
6/20/2014
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the lumi6aire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Intemally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 ' and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
' C ®�
UIL°lid C�LIIP��-q
BFETY
&
DEPT.
PP
ate CoNS7 RUCTION
ri A Tr
EnergyPro 5.1 by EnergySoft User Number: 52891 _ RunCode:-20OE?OT11:43:13 ID: 090513 Page 12 of 20
�J
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Ave La Fonda
Date
6/20/2014
System Name
HVAC System
Floor Area
1,622
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 804
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 1 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
0
16,195
2,408 332
12,832
Total Output Btuh
0
0
Output Btuh/s ft
0.0
935
631
Cooling System
0
0
Output per System
35,000
0
0 0
0
Total Output Btuh
35,000
0
935
1 18,065 2,408
0
Total Output Tons
2.9
631
Total Output Btuh/s ft
21.6
Total Output s ft/Ton
556.1
14,094
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow (cfm)
0
Goodman GSX130361B' 28,231 1,779
0
0
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
Outside Air %
0.0%
Total Adjusted System Output 28,231 1,779
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
F Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 OF 105 OF
Heating Coil 104 OF
ROOM In
_ 68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0cfmAL
!
76 63 °F
76/63°F 55/54°F
'✓'' f, jr
Cooling Coil BUILDING LAFETUINTQ_ 56!54°F
APPRO 176
FOR CONSTRUCTION 75 / 62 OF
DATE BY
EnergyPro5.1 by EnergySoft
User Number: 5289 RunCode: 201406-20TH:43:13 ID: 090513 Page 13 of 20
:O�
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Ave La Fonda
Date
6/20/2014
System Name
New 4 tons
Floor Area
1,175
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 856
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan0
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
0
16,798
1,365 277
10,674
Total Output Btuh
0
0
Output Btuh/s ft
0.0
970
525
Cooling System
0
0
Output per System
35,000
0
0 0
0
Total Output Btuh
35,000
970
1 18,737 1,365
0
Total Output Tons
2.9
525
Total Output Btuh/s ft
29.8
Total Output s ft/Ton
402.9
11,723
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Goodman GSX130361B• 28,344 1,619
0
Airflow cfm/s ft
0.00
Alrflow cfm/Ton
0.0
Outside Air %
0.0 %
Total Adjusted System Output 28,344 1,619 0
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 OF 105 OF
Heating Coil 104 OF
RO
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfmAL
77163 OF
77/63°F 55/54°F
Cooling Coil BU(LD(I1113 8, SAFE7� IN 57155 OF
FOP 4641,�a �b
INSTRUCTION 75 / 62 OF
1
VE
EnergyPro 5.1 by EnergySoR
User Number.- 5289 RunCode: 2014-06-20711:43:13 ID: 090513 Page 14 of 20
ROOM LOAD SUMMARY
Project Name Date
Ave La Fonda 6/20/2014
HVAC System 1,622
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible
Existing House Existing House 1 1 804 16,195 2,408 804 16,1951 2,408 3321 12,832
Total includes ventilation
EnerovPro 5.1 by Enerov:
PAGE TOTAL FBF
TOTAL*
I DATE
ire.
C�SQQ"'r
6 195u s2,408
332F 12,832
804
16,195 2,408
332 12,832
I ROOM LOAD SUMMARY
Ave La Fonda 6/20/2014
System Name Floor Area
New 4 tons 1,175
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible
New Living Area New Living Room + Bed F 1 1 856 16,7981 1,365 8561 16,7981 1,365 2771 10,674
PAGE TOTAL
TOTAL • F
Total includes ventilation load for zonal
1-k 1456-116,798
11;365 27
10,674
�R856
)N,Q'q;7.98
1;365 2
10,674
:l8 �--
Zt;B Zl i WOOEI UOd SSOI 1V3H AIynOH 1VIOI
866'6 =
l0
�-LJI
��//p�
-[0 /
lj�116��,►
06ed
ILL-!S,NOO
_H�y�
Ji.
•b ovb
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
j joj
r �.� �� „
` a �iy6iep 6ui�ia� easy algisueg
X? Q081i(��X ZZ9`l X b90'l
woomayloue-oolame ns joualw ue y6nwyl uoilonpuoo
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
o6£o,o X o*Za
006£'0 X E'b6
0660'0 X Z'bZE'6
OZovo X 6'066
0005'0 X 0 o
006£'0 X 0'68
0066'0 X Z'069
enleA-n eaJd
uoiloejd
it alnpayog
X 00'l Poneamul
alouep Q Isualse ue yl!m umoys swell
Zb
le;ol
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
ng'8
LO6
db
olnvlood of -b
bEZ
Zb
3 Mol iaasewaseD pe/0 uwew
4ZL'Z
Zb
7uasaid o7 Wt food alne{a(7
668
Zb
IIeM E6-8
0&1
Zb
X000 poom
9L£'6
Zb
IAWA .9-Mo7 olsse/O PLOBIW
996'Z
Zb
6666 019Z66IIeM;Ine)ap
i4/n38
do 1p
uollonpuoo
=10 89 ainleja wal gln8 U joopul
Jo 9Z ajn;ejadwal gln8 Aja joopino zy O'ZZ9 `l eaid Jool-q
WV; uef, dead;o aw!1 asnoH 6ugs/x3 aweN woos
SNowaNO3 NJIS3a NOIlVWEIOdNI WOOD
01OZ/071
9 epuo=f ej any
eleQ aweN loafed
SaVOI )Id3d JNIld3H WOOEI
ROOM HEATING PEAK LOADS
Project Name
Ave La Fonda 76/20/2014
Date
ROOM INFORMATION
DESIGN CONDITIONS
Room Name New Living Room + Bed Room
Floor Area 1,175.0 ftZ
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U -Value OT °F
749.2 X 0.0740 X 42
227.4 X 0.3900 X 42
1,166.0 X 0.0280 X 42
9.0 X 0.5500 X 42
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
through an interior surface to/,another room Page Total
X 1,175 X �I1000 j(]0'.3�7y���1 Xay
Area Ceiling Height--1,�:UACHSAF l� /X71
�+ �f Y
�,�P7'
=
=
=
=
Btu/hr
R-19 Wall
2,329
Milgard Classic Low -E Vinyl
3,725
R-38 Roof Cathedral
1,371
Double Non Metal Clear
208
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
7,632
2 = 3,041
TOTAL HOURLY HEAT LOSS FOR ROOM ! `"' cyrilS 1 ►nom„ 10,674
t
OAT&
EnergyPro 5.1 by EnergySoft User Number.- 5289 RunCode: 2014=06 20T11.43:13---�10.)090513 Page 18 of 20
��J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ave La Fonda
6/20/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Existing House
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,622.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor CLTD'
Btu/hr
Default Wall 1978 to 1991
(S) 385.0 X 0.1100 X 26.0 =
1,101
Wood Door
(S) 20.0 X 0.5000 X 26.0 =
260
Default Wall 1978 to 1991 •
(E) 255.2 X 0.1100 X 33.0 =
926
R-13 Wall
(S) 50.6 X 0.1020 X 26.0 =
134
R-13 Wall
(149 92.5 X 0.1020 X 33.01
311
R-13 Wall
(N) 47.0 X 0.1020 X 23.0 =
110
Default Roof 1978 to Present
(N) 1,324.2 X 0.0490 X 56.0 =
3,634
R-30 Roof Attic
(N) 82.0 X 0.0310 X 56.0 =
142
X J X =
Page Total
6,619
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
New Window
(S) 0.0 X 21.5 + 19.5 X 21.6
= 422
New Window
(S) 0.0 X 21.5 + 8.5 X 21.6
= 184
New Window
(S) 0.0 X 21.5 + 8.5 X 21.6
= 184
New Window
(S) 0.0 X 21.5 + 8.5 X 21.6
= 184
New Window
W 0.01 X 21.5 + 19.5 X 43.5
= 848
New Window
(E) 0.0 X 21.5 + 19.5 X 43.5
= 848
Skylight
(N) 0.0 X 19.3 + 14.3 X 59.9
= 857
X + X
-
X + X
-
Page Total
3,526
Internal Gain
Btu/hr
Occupants
4.0 Occupants X 230 Btuh/occ. =
920
Equipment
1.0 Dwelling Unit X 1,600 Btu =
1,600
Infiltration: 1.064
X 0.89 X 100.43 X 37 =
3,530
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,195
Latent Gain
Btu/hr
Occupants
_
4.0 Occupants X 1 ( iTV nc I200 Btuh/occ. =
800
�rUINTA
Infiltration: 4,771
�,� Ria ,�„ �,.°
��r��� & S,�IFETY DEPT.
X 0.89 X 100.43 X O,O03r76`L����
1,608
Air Sensible
CFM ELA pW i�- CD
C
FOR CONS TlnrKi
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I
2,408
EnerovPro 5.1 by Enem ySoft
User Number. 5289 RunCode: 201406-20T1"1:43:13- I x-090
Pae 19 of 20
J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ave La Fonda
6/20/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
New Living Room + Bed Room
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,175.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor CLTD'
Btu/hr
R-19 Wall
(E) 45.8 X 0.0740 X 33.0 =
112
R-19 Wall
(N) 406.4 X 0.0740 X 23.0 =
692
R-19 Wall
(149 238.7 X 0.0740 X 33.0 =
583
R-19 Wall
(S) 58.3 X 0.0740 X 26.0 =
112
R-38 Roof Cathedral
(N) 1,166.0 X 0.0280 X 56.0 =
1,828
X X =
X X =
X X =
X X =
Page Total
3,327
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
New Window
(N) 0.0 X 21.5 + 13.0 X 21.5
= 280
New Window (round)
(N) 0.0 X 21.5 + 3.1 X 21.5
= 67
New door
(Vtq 0.0 X 21.5 + 41.3 X 43.5
= 1,796
New door
(1M) 0.0 X 21.5 + 112.0 X 43.5
= 4,872
New Window
(IM 0.0 X 21.5 + 29.0 X 43.5
= 1,261
New Window
W 0.0 X 21.5 + 29.0 X 43.5
= 1,261
Skylight
(N) 0.0 X 36.7 + 9.0 X 127.4
= 1,146
X + X
-
X + X
-
Page Total
10,684
Internal Gain
Btu/hr
Occupants
1.0 Occupants X 230 Btuh/occ. =
230
Equipment
0.0 Dwelling Unit X 1,600 Btu =
0
Infiltration: 1.064
X 0.89 X 72.76 X 37 =
2,557
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,798
Latent Gain
;---�
Btu/hr
Occupants
1.0 Occupants X C.f200°•Btuhocc. =
200
Infiltration: 4, 771
LA QUI AA
X 0.89 X 72.76 X 0.0037611, F� & t
AFETY D P'
1,165
Air Sensible
CFM ELA /Aw � � p�.i
I Fr`)k CG°Vcr2VED
"
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I "" - -1 N 1
1 365
')ATF
EnemyPro 5.1 by EnemySoft
User Number. 5289 RunCode: 201406-20-T11:43:13�ID=0 513I
Pa a 20 o20