12-1302 (RER) Title 24Title 24 Report for:
J.M. Kendall L.L.C.
78-660 Avenida La Fonda
La Quinta, CA 92253
Report Prepared By:
Gabriel Rios
Rios Designs
49-901 Cinnabar Lane
Coachella, CA 92236
17.,1-$m
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE =54h.61P. , BY
Date:
03/30/2013
RECEIVED
APR 02 2013
COMM N ,C17 -Y OF D 4uINTq
EVELOpMENT
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations (Page 1 of 5
Project Name: Kendall Alteration climate Zone # 15 # of Stories
1
General Information '
Site Address: 78-660 Avenida La Fonda
Enforcement Agency:
Date: 03/30/2013
Building Type Single Family J@ Multi Family
Circle the Front Orientation: NQS, W, or degrees
Conditioned Floor Area (CFA): (E) 896 sQ.ft.
Project Type: El Alterations Envelope[] Fenestration Roof x HVAC
Replacement or Change Out x Duct Replacement C] Water Heater
NO This form is not to be used for Newly Constructed Buildings or Additions
Insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below)
Assembly Alteration
El Opening of framed cavity alone- Alterations that involve the opening of the framed cavity of a wall, ceiling, orfloor must install the
mandatory minimum insulation value per §150 for the altered assembly. Fill in Columns A -C and enter mandatory insulation value in Column H.
El Replacement of entire assembly- Replacement of an entire wall, ceiling, or,Jloor assembly requires the installation of Component
Packa e- D insulation values in Table 151-C Fill in Columns A -J.
Opaque Surface Details For the furred portioned of Mass Walls see Furring Strips Construction Table below.
A B I C D E
F G I H I I J
Proposed $Ce Note Standard
Values From JA4
Table
Added Interior or Exterior Insulation
Framing Thickness,
Framed
Continuous
JA4 Proposed
Tag/
Assembly Name Material Spacing,
U-
JA4 Table Cavity
Insulation
Assembly Assembly
ID�
or TYpe2 and Size2 or Other;
factor°
Numbef R-value6
R -Value?
Row/Cols U -facto?
N/A
Asscmblyg
0
•2 E- E~ o 0 > ;,
Final
Mass
wall 2x4 lad 16, O.C.
5c ° g
151-0 R-13
R-13
Thickness
T e Number' >
Roof 4x6 ® 24' O.C.
U-factorb
151-C RJO
R-30
Note: For furred assemblies, accounting for Continuous Insulation R -value, see Page JA4-3 and Equation 4-1. For calculating furred walls use the Mass and
Fvrrin Construction table below.
1. For Tag/ID indicate the identification name that matches the building plans.
2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate in column G the Frame
material and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies.
3. Enter the thickness for mass in inches or Spacing between framing members enter, 16 "or 24 "OC; or Other for all other assembly description
such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel and etc....
4. Based on the Climate Zone; enter the equivalent U factor found in JA4 Table based on the R -Value from Table 151-B, C, or D
5. Enter the Table number that closely resembles the proposed assembly.
6. Enter the R -value that is being installed in the wall cavity or between theframing, otherwise, enter "0 ".
7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0".
8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J
9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply.
Furring Strips Construction Table for Mass Walls Onl
A I B I C I D I E
F I G I H I J I K
L
M
Proposed Properties of Masonry and Concrete
Added Interior or Exterior Insulation
Walls From Reference
in Furring Space from Reference
Joint Appendix Table 4.3.5 4.3.6 4.3.7
Joint Appendix Table 43.13
c
d
U fL
C
Asscmblyg
0
•2 E- E~ o 0 > ;,
Final
Mass
Name or JA4 Table
5c ° g
Assembly'
Thickness
T e Number' >
e < >
U-factorb
Comment
N/A
Registration Number: Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations age 2 of 5
Project Name: Kendall Alteration Climate Zone # 15 # of Stories
1
Mass and Furring Strips Construction(footnotes)
1. Indicate the type of assembly to include; Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. Additional assemblies can
befound Reference Joint Appendix JA4.
2. This is the U -Factor based on the thickness of the assembly in inches.
3. The R -value of the insulation to be added on the interior or exterior of the assembly.
The Calculated R- Value is the R -value of the furred out section of the assembly.
-6. The Final Assembly is calculated using Equation 4-2 or Equation 4-4of the Reference Joint Appendix JA 4. The equation is the inverse of Column
added to Column L Column K is the inverse from column J.
7. Insert the calculated U- actor value on to the ue Surface Details in Column J
FENESTRATION PROPOSED AREAS
Replacing window alone — Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in
Table 151-C. The Total Fenestration and West facing Area requirements are not applicable.
E3Adding 50ft' or less of window area — Newly installed windows shall meet the U -Factor and SHGC Value requirements of Component
Package D in Table 151-C.
E] Adding more than 50ft2 ofwindow area — Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration
Area requirements of Component Package D in Table 151-C. Complete the Altered Fenestration Allowed Area Table on Page 2 of the CF -IR -ALT
Orientation
D
Fenestration Type and Frame (North, East, PropsedArea'
Window, Glass Door or Skylight) South, West) (fl U-factotz'
Maximum Maximum NFRC or Default
3 SHGC2- 3,4 Value
N/A
G
CFA of
Allowed
Existing
Allowed
1. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50.0 glass, the fenestration
area may be the glass area plus a 2 inch frame" around the glass.
2. Enter value from Component Package D Requirements in Table 151-C.
3. Actual fenestration products installed and as indicated in CF-6R-EN17 Form shall be equivalent to or have a lower U factor and/or a lower
SHGC value than that spec*d on the CF -IR ALT Form.
4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior shading.
5.1 applicable at this stage enter "NFRC"for NFRC Certified windows or are CEC "Default " valuesfound in Table 116-A or B.
ALTERED FENESTRATION
ALLOWED AREAS
(Complete if more than 50ft2
of fenestration is added)
A
B
C
D
E
F
G
CFA of
Allowed
Existing
Allowed
Entire
% of
Fenestration
Area
Fenestration
Area
Proposed Areal'
Dwelling
CFAZ' 3
Area°
Removed'
Area Added'
A x B
-D + C
Total Fenestration
Areaz ft'
>
—
West Fenestration Area
(Required In
CZ's 2,4&7-15
_
1. The Proposed West Fenestration Area includes West -sloping skylight area and any other skylight area with a pitch less than 1:12.
2. Enter 20% when no West orientation restriction or 15% when West fenestration is being installed in Climate Zones 2, 4, & 7-15. Note that the
maximum allowed fenestration can only be 5% of the CFA as indicated in Column F. Column G must be equal to or less than Column F.
3. In climate zones 2, 4, 7-15, no more than 5% of the CFA is allowed for west facing glazing.
4. Existing Fenestration area must be counted toward the maximum allowed 15% or 20% of the whole building and calculated in Column G. The
Proposed Area must be less than or equal to Column F.
5. Enter the fenestration removed as part of the alteration if any in column D.
6. Enter the Fenestration area that is being added as part of the alteration.
Registration Number: Registration Dat%Time: _ HERS Provider:
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations age 3 of 5
Project Name: Climate Zone # # of Stories
Kendall Alteration 115 1 1
ROOFING PRODUCTS (COOL ROOFS) §151(1)12
When the area of exterior roof surface to be replaced exceeds more than 50% of the existing roof area, or more than 1,000ft, whichever is
less, the new roofing area must meet the roofing product "Cool Roof' requirements of §152(b)IH4152(b)IM4 or 152(b)1Hili.
Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof' requirements. Note: If any
one of the alternatives or exception below is checkeg the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in
§118(1) are not applicable. Do not fill table below.
LJ Cool Roofs Not Required in Climate Zones 1-12,14, and 16 with a Low Sloped. Less or 2:12 pitch.
Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less
than 5lb/f
Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12)
Insulation with a thermal resistance of at least 0.85 hr82•°FBtu or at least a 3/4 inch air -space is added to the roof deck
over an attic; or
Existing ducts in the attic are insulated and sealed according to § 151(f)10; or
El In climate zones 10, 12 and 13, with I ft? of free ventilation area of attic ventilation for every 150 fl of attic floor area, and
where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or
Building has at least R-30 ceiling insulation; or
Building has radiant barrier in the attic meeting the requirements of § 151(f)2; or
® Building has no ducts in the attic; or
In climate zones 10, 11, 13 and 14, R-3 or greater roof deck insulation above vented attic.
Exception to §152(b)1Hiii, Low -slope roof (pitch:5 2:12)
E] Building has no ducts in the attic.
Other Exceptions
Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria.
Roof constructions that have thermal mass over the roof membrane with at least 25 lbIf is exempt from the below Cool Roof criteria.
Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise,
Check the applicable box below if Exem t from the Roofing Products "Cool Roof' R uirement:
Roof Slope
Product Weight
Product
Aged Solar
Thermal
CRRC Product ID Number
< 2:12 > 2:12
< 5lb/8> 51b/ft
T 2
Reflectance"4
Emittance
S
SRI
N/A
E3
13
11
Me
13
It
El
13
11
0
IT
El
0
El
®
Er
11
0
11
13
Er
I
1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www. coolroofs.orelproducts/search. ph
2. Indicate the type of product is being used for the rooftop, i.e. single ply roof, asphalt roof, metal roof, etc.
If the Aged.Reflectance is not available in the Cool Roof Rating Council's.Rated Product. Directory then use the.Initial Reflectance value from the same
directory and use the equation (0.2+0.7(p,,,;1ia1 — 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance.
4. Check bar ifthe Aged Reflectance is a calculated value using the equation above.
5. Calculate the SRI value by using the SRI- Worksheet at htto: //www. energy.ca.Aov/title24/ and enter the resulting value in the SRI Column above and attach acopy of
the SRI- Worksheet to the CF -IR
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating:
- Aluminum -Pigmented Asphalt Roof Coating
1E3 Cement -Based Roof Coating
Other
Registration Number: Registration DatelThmie _ HERS Provider:
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations (Page 4 of 5
Project Name: Kendall Alteration Climate Zone # ,� 5 # of Stories
1
HVAC SYSTEMS - HEATING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be
gas or propane fired Hot water pipe insulation from the DHW heater to the kitchen(s) and on all underground hot water pipes is required in all
Minimum Duct or Piping
Configuration
Heating Equipment
Efficiency Distribution Insulation
Thermostat (Central, Split,
I a,3
Type and Ca acity
AFUE or HSP Type and Location R -Value
Type Space, Package or H dronic
Existinq Unit #3
N/A Ducts in Attic 8.0
Setback Packaqe
Existing Unit #4
N/A Ducts in Attic 8.0
Setback Packaqe
1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc.)
2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity
< 2 KW or 7,000 Btu/hr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See §151(b)3 exception.
3. Refer to the HERS Verification section on Page 4 of the CF -I R -ALT Form for additional requirements and check applicable boxes.
4. Indicate Type or Location (Ducts, Hydronic in Floor, Radiators, etc.)
HVAC SYSTEMS - COOLING
Minimum
Efficiency
Duct or Piping
Configuration
Cooling Equipment
(SEER/EER or
Distribution Insulation
Thermostat (Central, Split,
Type and Capacity','
COP)
Type and Location' R -Value
Type Space, Package or H dronic
Existing Unit #3
N/A
Ducts in Attic 8.0
Setback Package
Existinq Unit #4
N/A
Ducts in Attic 8.0
Setback Package
1. Indicate Cooling Type (A/C, Heat pump, Evap. Cooling, etc)
2. Refer to the HERS Verification section on Page 4 of the CF -IR ALT Form for additional requirements and check applicable boxes.
3. Indicate Type or Location Ducts, H dronic in Floor, Radiators, etc.
WATER HEATING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be
gas or propane fired Hot water pipe insulation from the DHW heater to the kitchen(s) and on all underground hot water pipes is required in all
component packages in all climate zones.
External Tank
Water Heater Type/Fuel
Distribution Type
Number In
Tank
Energy Factor or
Insulation
T
Standard, Recirculating)
System
Capacity (gal)
Thermal Efficiency
R -Value'
Existina
1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.)
2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do
not allow the installation of a recirculating water heating system for single dwelling units.
3. The external water heating tank andpipess shall be insulated to meet the requirements o 150 ' .
SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below.
These items may require written 'ustication and documentation and special verification
NEW ROOF ASSEMBLY - Radiant Barrier
The radiant barrier requirement of § 151 2 does not apply to roof alterations.
Slab Edge (Perimeter) Insulation LJYES x NO
YES: In Climate Zone 16 in Component Packages D, R-7 insulation is required.
Heated Slab Insulation 0 YES 040
YES: Slab edRe insulation required for all heated slabs in all Climate Zones. See details in Table 118-A of the standards.
Raised Slab Insulation U YES ®x NO
YES: In Climate Zones 1, 2, 11, 13, 14 & 16, R-8 insulation isrequired; in Climate Zones 12 & 15, RA is required under component Package D.
Thermal Mass
To obtain Compliance Credit for the installation of thermal mass, use the Performance Approach.
Registration Number: Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations age 5 of 5
Project Name: Kendall Alteration Climate Zone # 15 # of Stories
1
HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this
checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final
inspection.
Duct Sealing & Testing HERS verification is required for this measure.
El YES Q NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned
space, the ducts are to be sealed per § 152(b)1 Dii and the newly installed ducts are to be insulated per § 151(f)10.
EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos.
EIYES EINO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the
ducts are to be sealed per §152(b)IDi.
®YES EINO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler,
outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) the ducts are to be
sealed per §152(b)IE.
EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS
verification in accordance with procedures in the Reference Residential Appendix RA3.
EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space.
rl EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos.
Refrigerant Charge - Split System HERS verification is required for this measure.
0 YES E) NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air
handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the furnace heat
exchanger) a refrigerant charge measurement shall be verified per § 152(b)1F.
Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw
The ventilationrequirements of § 150 o do not apply to existing residential homes.
Ducted Split Systems -Air Conditioners and Heat Pumps: Airflow HERS verification is required for this measure.
YES E) NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC equipment and ducting) is
replaced, the airflow and fan watt draw shall be verified per 152 1 Ci to meet the requirements of § 151(f)7B.
Documentation Author's Declaration Statement
• I cern that this Certificate of Com fiance documentation is accurate and corn ie�e.
Name:
Gabriel Rios
Signature: y�
!a'
Company: Rios Designs
Date: 03/30/2013
Address: 49-901 Cinnabar Lane
If Applicable - CEA or _ CEPE
(Certification #):
City/State/Zip: Coachella, CA 92236
Phone. 760485-7431
Responsible Building Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on
this Certificate of Compliance.
• I certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform
to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations.
• The building design features identified on this Certificate of Compliance are consistent with the information provided to document this
building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
Name: Gabriel Rios
Signature: 1h"
Company: Rios Designs
Date: 03/30/2013
Address: 49-901 Cinnabar Lane
License:
City/State/Zip: Coachella, CA 92236
Phone: 760-485-7431
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1-800-772-3300.
Registration Number:. Registration Date/Time: _ HERS Provider:
2008 Residential Compliance Forms March 2010
-Mandatory Measures Summa MF -1R
Residential(Page 1 of 3
Site Address: Enforcement Agency: Date:
78-660 Avenida La Fonda 03/30/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed,
regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -IR,
CF -IR -ADD, or CF -IR -ALT Form) shall supersede the items marked with an asterisk(*) below. This Mandatory Measures
Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum
component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all
applicable sections o the MF -IR Form with plans.
DESCRIPTION
-Building Envelope Measures:
§116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient
SHGC , and infiltration that meets the requirements of § 10-111 (a).
J117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
§ 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of
a Cool Roof is specified on the CF -1R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
1150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor.
1150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -IR Form.
§ 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§ 150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no
eater than 2.0perm/inch and shall be protected from physical damage and LTV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped
with a with a readily accessible, operable, and fight -fitting damper and or a combustion -air control device.
§ I50(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the
building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve,
backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 113(c)5.
§ 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an
electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters.
§ 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§ 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§ 1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
§ 1500) IB: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12
external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
§ 1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections
of hot water pipes are insulated per Standards Table 150-B.
§ 1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank
shall be insulated to Table 150-B and Equation 150-A.
§ 1506)2: Pipe insulation for steam hydropic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A.
1§ 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space.
2008 Residential Compliance Forms August 2009
Mandatory Measures Summa MF -1R
Residential(Page 2 of 3
Site Address: Enforcement Agency: 703/30/2013
:
78-660 Avenida La Fonda
§ 1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
Ducts and Fans Measures:
§ I50(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602,
603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or
enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable
requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to
seal openings ater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§ 150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,
duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts.
Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts.
§ 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape
is used in combination with mastic and draw bands.
§ 150(m)7: Exhaust fan systems have back draft or automatic dampers.
§ I50(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
§ 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that
can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in
Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§ 114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations;
an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use
electric resistance heating ora pilot light.
§ 114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return
lines, or built-up connections for future solar heating
§ 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only duiin off-peak electric demand periods.
§ 150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of § 150(p).
Residential Lighting Measures:
§150(k)l: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in
Table 150-C and is not a low efficacy luminaire asspecified by § 150 2.
§ 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d).
§ 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high
efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage
lamp holder; OR shall be rated to consume no more than five watts of power as determined by § 130(d), and shall not contain a medium
screw -base socket.
§ 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
§ 150(k)7: All switching devices and controls shall meet the requirements of § 150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft' or 100 watts for dwelling units larger than 2,500 ft2 may be exempt
from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§ 150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high
efficacy.
2008 Residential Compliance Forms August 2009
.Mandatory Measures Summa MF -1R
Residential (Page 3 of 3
Site Address: Enforcement Agency: Date:
78-660 Avenida La Fonda 3/30/2013
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of § 119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupant sensor.
§150(k)ll: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility
rooms shall be high efficacy luimnaires.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch
that complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the
applicable requirements of § 119.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply
with § 150(k) 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or
other nationally recognized testingtrating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then
2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing
and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling
units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot
shall be high efficacy.
EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual
on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the
following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an
energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be
always on
EXCEPTION 2: Outdoor -luminaires used to comply with Exceptionl to §.150(k)13.may be controlled by a temporary override switch
which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six
hours.
EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of
the California Electric Code need not be high efficacy luminaires.
§ 150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five
watts of power as determined according to § 130(d).
§ 150(k) l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in
Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of
Sections 130, 131, 134, and 146
§ 150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units
shall be high efficacy luminaires.
EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s)
certified to comply with the applicable requirements of § 119.
2008 Residential Compliance Forms August 2009
/ I �
/ `� / � �
/ �
/ �
�� i
/ �
� �i
'/ � / � , � �
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
12-00000851
54655 RIVIERA
775 -031 -014 -
RE -ROOF
LOW DENSITY RESIDENTIAL
24075
Architect or Engineer:
BUILDING & c
BUILE
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury�that I am licensed under provisions of Chapter 9 (commencing with
Property Detail Report Page 1 of 1
Property Detail Repan far:�DIGITASMMAP jegw,,mpp"
78660 AVENIDA LA FONDA, LA QUINTA CA, 92253-2816
Owner Information:
Owner Name: ^ LONE WOLF INVESTMENTS INC
Mailing Address: 17328.VENTURA BLVD 118, ENCINO, CA, 91316- 3904
Vesting Code:
TRUST
Phone.Number:
Location Information:
0000049544. Price Per SgFt:
Legal Description:
LOT 142 MB 021/061 DESERT CLUB TR UNIT5
Price Per Acre:
County:
RIVERSIDE - FIPS Code: 06065
Census Trct/Blk: 0451112/2
APN:
770145010 Alternative APN: 770145010
Map Ref: G7
Twnshp-Rnge-Sect:
- - Legal Book/Page: 770-14/
Tract No:
Legal Lot:
142 Legal Block:
FIDELITY NATIONAL TITLE
Subdivison:
DESERT CLUB TR UNIT 05
Last Market Sale Information:
Sale Date:
02/03/2012 Sale Price:
$175,000 1st Mtg Amount:
Sale Doc No:
0000049544. Price Per SgFt:
1st Mtg Int Type:
Transfer Doc No:
Price Per Acre:
2nd Mtg Amount:
Multi/Split Sale:
1st Mtg Doc No:
2nd Mtg Int Type:
Sale Type:
FULL CONSIDERATION
Deed Type:
Title Company:
FIDELITY NATIONAL TITLE
Lender:
Seller Name:
FISCHER MICHAEL A SR
Property Characteristics:
Building Area:
Total Rooms:
Construction:
Living Area:
Bedrooms
Heat Type:
Garage Area:
Baths:
Air Cond:
Basement Area:
Fireplace:
Roof Type:
Parking Type:
No of Stories:
Roof Material:
Yr Built/Effective:
/ Quality:
Style:
Pool Code:
Tax and Value Information:
Assessed Value: $104,641
Assessed Year: 2011 Est Market Val: $135,935
Land Value: $26,440
Property Tax: $3,155 Assessor Appd Val:
Improvement Value- $76,701
Improvement %:
Total Taxable Value: $104,641
Tax Exemption:
Site Information:
Assessor Acres:
Zoning: R1 Land Use: 131
Assessor Lot SgFt: No of Buildings: Land Use Desc: MULTI FAMILY >
10 UNITS
Assessor Lot W/D: / Res/Comm Units: County Use Code: CA
Calculated Acres: 0.3110 Sewer Type: ,
Calculated Lot SgFt: Water Type:
http://maps.digitalmapcentral.com/production/citygis/v07_O3_001/index.p7.aspx 10/9/2012
Branch 'IRV,User:AD09 Comment: Station Id :ZRXF
Space above this One for recorders use only
TPA-, (v 2.c? o 1
�D T ~ 4 -24-2-'
Title of Document
THIS PAGE ADDED TO PROVIDE ADEQUATE SPACE FOR RECORDING INFORMATION
($3:00 Additional Recording Fee Applies)
ACR 238P-AS4REO (Rev. 0312Do8)
RIVERSIDE,CA Page I of 5 Printed on 10/9/2012 12:26:09 PM
Document: DD 2012.447951
DOC # 2012-0447961
09/19/2012 03:36 PM Fees: $27.00
Page 1 of 5 Doc T Tax Paid
Recorded in Official Records
County of Riverside
Larry W. Ward
PLEASE COMPLETE THIS INFORMATION
Assessor, County Clerk & Recorder
RECORDING REQUESTED BY:
Advantage Tiger 1nr,
"This document was electronically submitted
AND WHEN RECORDED MAIL TO:.
to the County of Riverside for recording"
Receipted by: YSEGURA
2 3o L,ok k �.+ u v Ve(
`rll�(�blttil�r �a- 2C2.J3
Space above this One for recorders use only
TPA-, (v 2.c? o 1
�D T ~ 4 -24-2-'
Title of Document
THIS PAGE ADDED TO PROVIDE ADEQUATE SPACE FOR RECORDING INFORMATION
($3:00 Additional Recording Fee Applies)
ACR 238P-AS4REO (Rev. 0312Do8)
RIVERSIDE,CA Page I of 5 Printed on 10/9/2012 12:26:09 PM
Document: DD 2012.447951
Branch '':1RV,User :AD09 Comment: Station Id :ZRXF
Title 365
RECORDING REQUEsrED By: w
Aavamase rile .
WHEN RECORDED, MAIL TO:
JM KmdalL LLC
4230 White Lilac Road
Fallbrook, CA 92028
ASSESSORS PARCEL NO; 770.145-010
TITLE ORDER NO.: 5I0.1203122-50
ESCROW NO.: 12 -1410 -DM
DOC # 2012-0447951
Page 2 of 5 09/19/2012 03:36 PM
wicu _ r KQ SPAC2 FOR RETARDERS USE ONLY
�� !GGRANT DEED ,. 04A_X_4��
The tardOft� G M=ds) Acehn: tha the DOCUMENTARY TRANSFER TAX LS: r0/
S 2Caa Cwaan- —V1 /`
>I>t eompaeed oa dtc fu0 raFsaf me Tamest of pmpery eemcyoi v C /1
_ eempmd oo the 6t➢nhCe bs �e.abe ofSmramnmbaoem re,tsmnatlwtse>tthcdmcefak
_ OR male i. E)MM fiom= fordo fo0wma neve
FOR A VALUABLE CONSIDERATION, receipt of which is bereby aclmowlodged, Lune Wolf investments, by., a
c4ifexni. Corporation
HEREBY GRANT(S)toffJ��MKendall, LLC' a California Limited Liability
All that real property situs RNFP Wof La Quina. County of Rivetside, State of CA described as:
EXbibit "A- attached hereto and made a part hereof by this referencc.
Commonly Known As: 78660 Avenida La Fonda, La Quints, CA 92253
Dated: August 31, 2012
STATE OF CALIFORNIA I _ I
COUNTY OF _LAS tihQ C IGS I
oe Ce*Mber 9' 2 012 bcfare n,e,
.TIT tr_J6s1GGuiG2. 'tJofar r %61ir"
(her im Dame and dd, of the o ('
pesonally appeared Leat }h R l So f e Y
who proved to trte on the bam of ansfamory evidenm to be the
peraajal'Gitose mar e! bed to the within ctmun cra
and adoauied;ed to me eaeaued the ane in
.uraonsc tau *ca ar or t at by ti
fi the irotnrrrrrnt drc ar the tntity upon bdWf
*(which the pesor(( YS&d, seated the 4.w nee.
1 mtily under PENALTY OF PERJURY anile the laws of the Sus
of California that the foregoing Paragraph is tree and caret
WRNESS my hand and official ad.
Lone Wolf Invt:3Mw=s, Inc., a California Corpmadm
nje-M-
A LS -e -U; qEiSt &X -J_
L Ew - J IF JA I CZ
COn111Ngbt1l i
is LOS k"" Nehrr PIbk - CaNkrMs
0 C� 1b
(SEAL)
RIVERSIDE,CA Page 2•of 5 Printed on 10/9/2012 12:26:10 PM
Document: DD 2012.447951
Branch 'IRV,User :ADW Comment: Station Id :ZRXF
RECORDING REQUESTED BY:
Advantage Title
WHEN RECORDED, MAIL TO:
JM Kendall, LLC
4230 White -Lilac Road
Fallbrook, CA 92928
ASSESSOR'S PARCEL NO.: 770-145-010
TITLE ORDER NO.: 510-1203122-50
ESCROW NO.: 12 -1410 -DM
r ..
DOC # 2012-0447951
Page 3 of 5 09/19/2012 03:36 PM
1 DECLARE UNDER THE PENALTY OF PERJURY
THAT THE FOREGOING IS A TRUE AND
ACOORR CT COPY OF THE ORIGINAL
;�p
SIGN 11 l ` 12 DATED
PLACE--
THIS
LACE
THIS SPACE FOR RECORDERS USE ONLY
GRANT DEED
The urdasigned Grantor(s) declare that the DOCUMENTARY TRANSFER TAX IS:
S 24200 County
2421 computed on the full value of the interest of property conveyed, or
computed on the full value hss the value of urns or encumbrances remaining thereon at the time of sale.
_ OR transfer is EXEMPT fiom tax for the following reason
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Lone Wolf Investments, Inc., a
California Corporation
HEREBY GRANT(S) to JM Kendall, LLC, a California Limited Liability
Company
All that real property situated in the City of La Quinta, County of Riverside, State of CA, described as:
Exhibit "A" attached hereto and made a part hereof by this reference.
Commonly Known As: 78660 Avenida La Fonda, La Quinta, CA 92253
Dated: August 31, 2012
STATE OF CALIFORNIA }
COUNTY OF i Lone Wolf Investments, Inc., a California Corporation
On before me,
(here insert name and title of the officer)
personally appeared
who proved to me on the basis of satisfactory evidence to be the
person(s) whose name(s) is/are subscribed to the within instrument.
and acknowledged to me that he/she/they executed the same in
his/her/their authorized capacity(ies), and that by his/her/their
signature(s) on the instrument the person(s), or the entity upon behalf
of which the person(s) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State
of Califomia that the foregoing paragraph is true and correct.
WITNESS my hand and official seal.
Signature
By:
(SEAL)
RIVERSIDE,CA Page 3 of 5 Printed on 10/9/2012 12:26:10 PM
Document: DD 2012.447951
Branch! IRV,User :AD09 Comment: Station Id :ZRXF
DOC # 2012-0447951
.� Page 4 of 5 09/19/2012 03:36 PM
EXHIBIT "A"
The land referred to in this Report is situated in the County of Riverside, State of California, and is described as follows:
Lot 142, of Desert Club Tract, Unit No. 5, in the City of La Quinta, County of Riverside, State of California, as shown by
map on file in book 21, pages 61 and 62 of maps, recorded on in the office of the county recorder of Riverside County,
California.
APN: 770.145-010-5
i
RIVERSIDE,CA Page 4 of 5 Printed on 10/9/2012 12:26:10 PM
Document: DD 2012.447951
Branch :1 RV,User :AD09
Comment:
11
DOC # 2012-0447951
Page 5 of 5 09/19/2012 03:36 PM
NOTARY CLARITY
Under the provisions of Government Code 27361.7, 1 certify under the penalty of perjury
that the notary seal on the document to which this statement is attached reads as
follows:
Station Id :ZRXF
Name of Notary:
Commission M
Place of Execution: S
Date Commission Expires: G123'
Date:
J
Signature:
Print Name: L
ACR 186P•AS4REO (Rev. WNW
Availabk in Alternate Formats
RIVERSIDE,CA Page 5 of 5 Printed on 10/9/2012 12:26:10 PM
Document: DD 2012.447951
Property Information Center
.:T"irtgn
assessor-cour���c�er�-Recorder
♦ , °c r
Home Search Again
Property Information Center
Property Information for the 2012-2013 tax year as of January 1, 2012
Property Information
Parcel Number:
770145010-5
Property Address:
78660 AVENIDA LA FONDA
Property
LA QUINTA CA 92253
Legal Description:
Lot 142 MB 021/061DESERT CLUB TR UNIT 5
Property Type:
CAssessment-Desoription:_6_UM
.APARTMENT BUILDINGS
Full Value
TS
Year Built
N/A
Square Feet:
N/A
Bedroom:
N/A
Bath:
N/A
Pool:
N
Lot Size:
N/A
Sales Information
Last Recorded Document:01/2001
Recording Number: •
0009182
Assessed Value Information
Page 1 of 1
Tuesday, October 9. 2012 12:31:51 PM
Land
26,968
Structure
78.235
Business Personal
1,500
Property
150
Penalty Per Sec. 463, R&T
NOT IN AN AGRICULTURE PRESERVE
Code
DESERT SANDS UNIFIED
Full Value
106.853
Total Net
106,853
Assessment Information
Assessment Number:
770145010-5
Tax Rate Area:
020-021
Taxability Code:
0-00
Base Year:
1996
Parcel Map
View Parcel Map
Related Property Information
City Sphere:
LA QUINTA Tax Assessment District
Supervisorial District:
John J. Benoit
Landuse Designation:
CITY
Agriculture' Preserve:
NOT IN AN AGRICULTURE PRESERVE
School District:
DESERT SANDS UNIFIED
Water District:
CVWD
Fema Flood Plan:
FLOOD ZONE 0.2 PCT ANNUAL
For more information please visit the following links
County of Riverside Assessor - County Clerk - Recorder
Change of Address Clerk of the Board
CITRUS PEST CONTROL 2
CITY OF LA QUINTA
CITY OF LA QUINTA RDV
COACHELLA VAL JT BLO HIGH
COACHELLA VALLEY PUBLIC CEMETERY
COACHELLA VALLEY REC AND PARK
COACHELLA VALLEY RESOURCE CONSER
COACHELLA VALLEY WATER DISTRICT
COUNTY FREE LIBRARY
COUNTY STRUCTURE FIRE PROTECTION
CSA 152
CV MOSQ & VECTOR CONTROL
CVWD IMP DIST 1 DEBT SV
CVWD IMP DIST 55
CVWD STORM WTR UNIT
DESERT COMMUNITY COLLEGE
DESERT SANDS UNIFIED SCHOOL
GENERAL
GENERALPURPOSE
RIV. CO. OFFICE OF EDUCATION
Pay your Taxes'Online
Riverside County Board of Supervisors
O Copydght 20052011 Riverside County AR rights reserved.
9
http://pic.asrclkrec.com/KSearchDetails.aspx?Assessment=770145010 10/9/2012
Business Search - Business Entities - Business Programs
Page 1 of 1
Secretary of State Administration Elections Business Programs Political Reform Archives Registries
Business Entities (BE)
Online Services
Business Search
Disclosure Search
E -File Statements
Processing Times
Main Page
Service Options
Name Availability
Forms, Samples & Fees
Annual/Biennial Statements
Filing Tips
Information Requests
(certificates, copies &
status reports)
Service of Process
FAQs
Contact Information
Resources
Business Resources
Tax Information
Starting A Business
International Business
Relations Program
Customer Alerts
Business Identity Theft
Misleading Business
Solicitations
Business Entity Detail
Data is updated weekly and is current as of Friday, October 05, 2012. It is not a complete or certified
record of the entity.
Entity Name:
JM KENDALL, Ll_C
Entity Number:
201127810096
Date Filed:
10/04/2011
Status:
ACTIVE
Jurisdiction:
CALIFORNIA
Entity Address:
4909 MURPHY CANYON DR STE 340
Entity City, State, Zip:
SAN DIEGO CA 92123
Agent for Service of Process:
JASON KENDALL
Agent Address:
4230 WHITE LILAC ROAD
Agent City, Stater Zip:
FALLBROOK CA 92028
z Indicates the information is not contained in the California Secretary of State's database.
* Note: If the agent for service of process is a corporation, the address of the agent may be
requested by ordering a status report.
• For information on checking or reserving a name, refer to Name Availability.
• For information on ordering certificates, copies of documents and/or status reports or to request a
more extensive search, refer to Information Requests.
• For help with searching an entity name, refer to Search Tips.
• For descriptions of the various fields and status types, refer to Field Descriptions, and Status
.................................. _.........._......_.._._
Definitions.
Modify Search New Search Printer Friendly Back to Search Results
Privacy.StaLement I Free Document Readers
Copyright p 2012 California Secretary of State
http://kepler.sos.ca.gov/cbs.aspx 10/9/2012
Property Detail Report Page 1 of 1
a .
•DIGITAL MAP', BMjOtdFLappir+g
,property Detaif'Report for: � aH,r}ucrs
78660 AVENIDA LA FONDA, LA QUINTA CA, 92253-2816
Owner Information:�T..__-..-
Owner Name: LONE WOLF INVESTMENTS INC
Mailing Address: 17328 VENTURA BLVD 118, ENCINO, CA, 91316- 3904
Vesting Code:
TRUST
Phone Number:
Location Information:
Legal Description:
LOT 142 MB 021/061
DESERT CLUB TR
UNIT 5
County:
RIVERSIDE
FIPS Code:
06065
Census Trct/Blk: 0451112 12
APN:
770145010
Alternative APN:
770145010
Map Ref: G7
Twnshp-Rnge-Sect:
- -
Legal Book/Page:
770-14/
Tract No:
Legal Lot:
142
Legal Block:
Subdivison:
DESERT CLUB TR UNIT 05
Last Market Sale Information: +������.^-���
____._.._.�.. - •.__.
� ._.T._____ ____..._.,.�,� _ _ .�
Sale Date:
02/03/2012
Sale Price:
$175,000
1St Mtg Amount:
Sale Doc No:
0000049544
Price Per SgFt:
1St Mtg Int Type:
t' Transfer Doc No:
Price Per Acre:
2nd Mtg Amount:
MultdSplit Sale:
1St Mtg Doc No:
2nd Mtg Int Type:
Sale Type:
FULL CONSIDERATION
Deed Type:
Title Company:
FIDELITY NATIONAL
TITLE
`
Lender:
Seller Name:
FISCHER MICHAEL
A SRS'
J
_ V
Property Characteristics:
Building Area:
Total Rooms:
Constructi n:
Living Area:
Bedrooms
Heat Type:
Garage Area:
Baths:
Air Cond:
Basement Area:
Fireplace:
Roof Type:
Parking Type:
No of Stories:
Roof Material:
Yr Built/Effective:
/
Quality:
Style:
Pool Code:
Tax and Value Information:
Assessed Value:
$104,641
Assessed Year:
2011
Est Market Val: $135,935
Land Value:
$26,440
Property Tax:
$3,155
Assessor Appd Val:
Improvement Value:
$76,701
Improvement %:
Total Taxable Value:
$104,641
Tax Exemption:
SiteInformation: ......~
�___._._..._._.._.._..,_,_...__._.______.........._.._._
_.._.....___,...._.._..�...._.___..,_.._.__.._....._..�_.______..._,..�_....
Assessor Acres:
Zoning:
R1
Land Use: 131
Assessor Lot Sq Ft:
No of Buildings: '
Land Use Desc: MULTI FAMILY >
10 UNITS
Assessor Lot W/D:
/
Res/Comm Units:
County Use Code: CA
Calculated Acres:
0.311
Sewer Type:
Calculated Lot SgFt:
Water Type:
http://maps.digitalmapcentral.conilproductionlcitygislvO7_O3_001lindex.p7.aspx 10/9/2012