Loading...
0211-152 (AR) Title 24 Revised 3:. TITLE 24 REPORT Title X24 Report for: Casita La Qui nta, CA 1 Prol ect Designer: Report Prepared By: William A. Pope Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: CITY OF LA QIJIN F-' BUILDING 8� SAFETY D� APPROV FOR CONST CTION I DATE 6 BY CH030503 Date: 3/7/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with boih the Residential and Nonresidential 2001 Building Energy Efficiency Standards. `y This program de' eloped by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft [Job Number: CH030503 User Number. 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 13 i i I } 9 1 Ceirtificate of Compliance: Residential (Part 1 of 2) CF -1 R Casita { 3/7/2003 Date Project Title La Quinta Building Permit # Project Address Insu-Form Inc. ( (760) 324-0216 Telephone Plan Check / Date Documentation Author Computer Performance 15 a Climate Zone Field Check / Date Enforcement Agency Use Only Compliance Method (Package or Computer) GENERAL INFORMATION Total Conditioned Floor Area: 363 ft' Total Conditioned Slab Area: 363 ft' Building Type: (check one or more) Single Family Detached ❑ / ❑ Single Family Attached ❑ I ❑ Multi -Family ❑ I Front Orientation: (WE'st) 270 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Average Ceiling Height: 9.0 ft isting Building isting Plus Addition Construction Type: ® Slab Floor ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type I U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-19 Wall/w 1" EPS Wood 0.047 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation FENESTRATION Rh�riinn rinvircc Type Orientation Area I Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Front (West) 20_0 0.50 0.62 Bug Screen x❑ ❑ ❑ x❑ Front (West) 24_0 0.55 I 0.65 Bug Screen X❑ ❑ ❑X❑ Rear (East) 30_0 0.50 0.62 Bug Screen X❑ ❑ ❑ X❑ - i ❑❑ 1:1 El _ f ❑❑ 1:1 El _ 1:1 1:1 El El _ ► 1:1 El El _ El El El i 1:1 1:1 ❑❑ a El El El F-1 El El El El 0 Run Initiation Time: 03/07/03 14:36:02 Run Code: 1047076562 Ener Pro 3.1 By EnerqySoft User Number: 2655, Job Number: CH030503 Page: 3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Casita 3/7/2003 Project Title I Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Heating Equipment Minimum Distribution Type and Duct or Type (furnace, heat pump, etc.) Efficiency Location (AFUE/HSPF) (ducts, attic, etc.) Piping R -Value Thermostat Location / Type Comments Flpntric 0.89 HSPF Ducts in Attic 42 Setback Casita Cooling Equipment Minimum Duct Type (air conditioner, Efficiency heat pump, evap. cooling) (SEER) Location (attic, etc.) Duct R -Value Thermostat Location / Type Comments Split Air Conditioner —1Z0 SEER _ Ducts in Attic t 42 Sethack (';mita _ WATER HEATING SYSTEMS Water Heater Water Heater Distribution i I I # in Rated 1 Input Tank Energy Facts 1 External Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A -C. Smith FSG -30-222 Small Gas Standard 1 32,000 30 0.62 n/a n/a i 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS . COMPLIANCE STATEMENT This certificate of compliance lists the building features a California Code of Regulations, and the administrative re overall design responsibility. The undersigned recognize and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Name: Title/Firm: Address: /1 Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: performance specifications needed to comply with Title 24, Parts 1 and 6 of the ations to implement them. This certificate has been signed by the individual with t compliance using duct sealing and TXV's requires installer testing and certification Documentation Author Name: William A. Pooe Title/Firm: Insu-Form Inc. Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-0216 JEnergyPro 3.1 By EnergySoft User Number: 2655, - _ Job Number: CH030503 PageA of 13 1 4 Certificate of Compliance: Residential (Addendum) CF -1 R Casita ! 3/7/2003 Project Title ( Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "Casita" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 363 sgft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. Tne t1E_K5 rater must document the Two venticati i n ana diagnostic testing of tnese measures on a torm cF-6K. Plan Field r Run Initiation Time: 03/07/03 14:36:02 Run Code: 1047076562 EnergyPro 3.1 By EnergySoft i User Number. 2655; Job Number. CH030503 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an i asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere: in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value l. ❑X §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ! f a § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. I §150(l): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. 1 X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. i ®§116.17: Fenestration Products, Exterior Doors and Infiltratio n/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label l with certified —Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. l 3. Exterior doors and windows weatherstripped; all joints +nd penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑1 § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. I ❑ Installation Fireplaces, Gas § 150(e): of Decora five Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. I Space Conditioning, Water Heating and Plumbing System Measures I o§ 110-13: HVAC equipment, water heaters, showerheads aInd faucets certified by the Commission. FV § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. i § 150(i): Setback thermostat on all applicable heating and/or cooling systems. I ❑X § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 1 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect i of water tank. EnergyPro 3.1 By EnergySoft User Number. 26551 Job Number: CH030503 Page:6 of 13 Mandatory Measures Checkllist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. I (DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. ! DESIGNER ENFORCEMENT 1 Space Conditioning, Water Heating and Plumbing System Measures: (continued) �X !§150(m): Ducts and Fans , 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 1 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings I y,edltl, uldn n9 (nun, [ne uumuinauun ur ma5uc ana enner mesn or tape Snail De used. tsunaing cavities snail not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and i I drawbands. 1 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other ! ; i than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building i cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be l ; compressed to cause reductions in the cross-sectional area of the ducts. I 'i 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive I duct tapes unless such a tape is used in combination with m lstic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. j 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually l j operated dampers. i i 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, I I ! equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam j insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the mate 1. I Ii F�i § 114: Pool and Spa Heating Systems and Equipment I i 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. i 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. +I a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. i j ;X jj §115: Gas fired central fumaces, pool heaters, spa heaterslor household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) I I i II § 118 (f): Cool Roof material meet specified criteria i Lighting Measures §150(k)1: i Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be!controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. JI §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of i 40 lumenstwatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fxturesiare IC (insulation cover) approved. i j 3.1 By EnergySoft User Number: 2655 Job Number. CH030503 Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R 3/7/2QQ3 Project Title —La-Quinta Project Address Building Permit # _1aS_u=E0rm-h1c __ (760) 324-0216 Documentation Author Telephone Plan CheckiDate Computer-Re.>format e — 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 0.09 0.00 0.09 Space Cooling 47.51 . 57.04 -9.54 Domestic Hot Water 49.95 39.99 9.96 Totals 97.54 97.03 0.51 GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name OPAQUE SURFACES Act. 363 Single Fam Detached (West) 270 deg 1.00 1 Floor Area Volume Type Area U -Fac. Azm. _Tilt Boot 36.0 0.028 270 _ 22 Wall 12 0 047 270 _ 9.0 Call— 40 _0-047 —90 _fin -OCall— X00 0,047 180 _L—K ?Xj Slab Floor Floor Construction Type: 11 Raised Floor Total Fenestration Area: 20.4% Total Conditioned Volume: 3,267 Slab Floor Area: 363 # of Units 163 _3,262 1 no Solar Gains Zone Type Conditioned YY / NN Form 3 Reference Liv U X38 B0of (R.382x14.16) ❑ R-19 Wall/w 1" EPS � II R-19 Wall/w 1" EPS ❑ R1�1Nall/w 1" EPS n❑ II❑ ❑❑ F-1 F, ❑❑ F-1 1-1, ❑❑ F-1 F] ❑❑ nn 71 1-1 ❑ 1 _ ❑ L1 F-1 F-1 ❑ ❑ ❑n F-1 F-11 F-1 F-1 El 01 Thermostat Vent Type Hgt. Area Sethack —2 n/n Location / Comments EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: CH030503 Page:B of 13 1 Computer Method Summary 4.0 2.0 0.1 (Part 2 of 3) C -2R 2.0 8.0 3.0 2.0 0.1 Casita 2.0 5.0 4.0 2.0 0.1 3/7/2003 Project Title 2.0 5.0 2.0 0.1 2.0 Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 4 Window Front pl_llesfa. _2Q_0_ X500_ -0.62 _270_ -9.Q Veno -Windows Casita 2 Window Front est 24.0 0.550 0.65 270 90 Wenco Windows Casita 3 Window Rear ' (East) 20.0 0.500 0.62 90 90 Wenco Windows Casita 4 Window Rear (East) 10.0 0.500 0.62 90 90 Wenco Windows Casita INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 Bug Screen 0.76 2 Bug Screen _ 0.76 3 Bug Screen _ 0.76 4 Bug Screen 0.76 Window Hgt. Wd. 5.0 4.0 2.0 0.1 2.0 2.0 8.0 3.0 2.0 0.1 2.0 2.0 5.0 4.0 2.0 0.1 2.0 2.0 2.0 5.0 2.0 0.1 2.0 2.0 Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. Run Initiation Time: 03107/0314.3602 Run Code: 1047076562 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: CH030503 Page:9 of 13 Computer Method Summary III (Part 3 of 3) C -2R Casita I 3/7/2003 Project Title I Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Cote HeavKw_ejght_ —3 63 -3-50 —28 X9.8 Na _0 CasitaLSlab-orLG[ade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments ba aerir eter 5 Q1-6 --0 0 0 Casita ( HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Electric 0.8Sii d,SP� Ducts in Attic 4.2 SetbaCj — -C-asita I Location / Comments Hydronic Piping Pipe Pipe Insula System Name Length Diameter Thick! Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc) C-14 Aim (`nn.l ili..- 4n A 0CC6 P1-1- :.- AJ - Duct Thermostat Location / R -Value Type Comments 4.2 Setback Casita I WATER HEATING SYSTEMS Rated Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type, Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. Smith FSG -30-222 $mall as Standard 1 32,000 30 0.62_ n/a n/a For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (riled input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS i 3.1 Computer Method Summary (Addendum) C -2R Casita 3/7/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the aaequacy or the speaai tustiTication ana aocumentation suomittea. The HVAC System "Casita" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 363 sgft Exposed Slab Floor, 3.50" thick at Casita 11 HERS Required Verification These features must be confirmed and/or tested bjr a certified HERS rater under the supervision of a CEC approved HERS I1--.. 111. ally 11- •GI11I-W1ION IU YIal,11VJL9{ LCJLIIILU VI u1CJC II ucmutcp UII C lurm Err -O R. 10 Plan I Field Run Initiation Time: 03/07/03 14:36:02 Run Code: 1047076562 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. CH030503 Page: 11 of 13 i MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME I DATE Casita J 1 3/7/2003 'SYSTEM NAME ' Casita ENGINEERING CHECKS __= SYSTEM LOAD 'Number of Systems I iHeating System I Output per System37,000 1.5� Total Output (Btuh/sgft) 1 Total Room Loads i Total Output (Btuh) 37,000 11 Return Vented Lighting ! Outside Air (cfm/sgft) 1 0.001 Output (Btuh/sgft) 101.911 I Return Air Ducts System Return Fan ,;Cooling I Output per System 1 18,000;, Ventilation I Total Output (Btuh) I 18,00011'!' Supply Fan Total Output (Tons) 1.5� Total Output (Btuh/sgft) I 49.61 Total Output (sgft/Ton) 242.01 !Air System 0.0 1 1 li Supply Air Ducts I! TOTAL SYSTEM LOAD FLOOR AREA 363 COIL COOLING PEAK ! : COIL HTG. PEAK ' CFM Sensible Latent CFM Sensible 871 7,691 -80 1061 3,948; 0 ' 385'• 197; 0, 01 i 1 OI 0i 01 0i 0, 0i ! 0, j 3851 I 19T j 8,461 -80 1 4,3431 i I �{ HVAC E UIPMENT SELECTION I I CFM per System j 895I A'rfl f ! IIi,YORK E1RCO24S06 15,0701 0 0i I ow (c m) 1 895, 1 Airflow (cfm/sgft) 1 2.471 1 Airflow (cfm/Ton) 596.71 I Outside Air (%) 0.0 1 1 ! Outside Air (cfm/sgft) 1 0.001 I I1 Total Adjusted System Output , 11 (Adjusted for Peak Design Conditions) I 15,0701 Oi 1 37,0001 . 1 TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am; i Note: values above given at ARI conditions ; f EATING SYSTEM PSYCHROMETRICS (Airstrea 26.0 OF 69.8°F 69.8 OF 1( i I Outside Air'f A ` j 0 cfm I Supply Fan Heating Coil 1 895 cfm 69.8 of OF res at Time of Heati �% Return Air Ducts 4 Supply Air Ducts 104.8 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 1115.0 / 73.5 of 78.4 / 62.3 of 78.4162.3 of . 69.7 / 59.2 OF I S I A' D t Outside Air 0 cfm 78.4/62.3 OF Supply Fan I Cooling Coil 895 cfm � Return Air Ducts 4 upp Ir y uc s 40.8% R.H. I 70.1/59.4 of j ROOMS 78.0/62.1OF 1 i 1 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. CH030503 Paoe:12 of 13 i IROOM LOAD SUMMARY PROJECT NAME Casita DATE 3/7/2003 SYSTEM NAME Casita FLOOR AREA 363 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Casita 1 871 7,691 -80 871 7,691 -80 106 3,948 j EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. CH030503 Page: 13 of 13 0 TITLE 24 REPORT Title 24 Report for: Casita La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 e'�'t"��QP�pJ SON Job Number: Date: 11/15/2002 The EnergyPro computer program hcis been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergvPro 3.1 By EnergvSoft " Job Number: User Number. 2655 I TABLE OF CONTENTS Cover Page A Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatary Measures Checklist IForm C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 } I J 1 2 3 6 8 12 13 } EnergyPro 3.1 By EnergySoft Job Number. User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Project Title La Quinta Project Address Insu-form, I Documentation Authori eiepnone I Comnuter Performance 15 11/15/2002 _ Date Building Permit # Plan Check / Date Field Check I Date Compliance Method (Package or Computer) I comate cone Enforcement Agency use Only GENERAL INFORMATION . Total Conditioned Floor Area: 363 ft2 Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: _ ft2 Building Type: ' (c�hhelck one or more) In 1 Single Family Detached X❑ Addition Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: __. (WE3st) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 0.25 Number of Stories: 1 E] Raised Floor oui�unw Component Type Frame Type Const. (Assembly U -Value Location/Comments (attic, garage, typical, etc.) Slab On Grade R-19 Wall (W.19.2x6.16) R-38 Roof (R.38.2x14.16) i I I , n/a Wood Wood 0.756 Exposed Slab w/R-0 0 Perimeter Insulation 0.065 Exterior Wall 0.028 Exterior Roof FENESTRATION t Shading Fenestration Exterior SHGC Shading Devices Overhang Side Fins Yes / No Yes / No Type Orientation Area (SF U -Factor Front (West) Front (West) Rear (East) Rear (East) 20_0 24.0 :20.0 10.0 i 0.57 0.27 0.57 0.57 i i i i i i 0.36 _ Bug Screen 0.21 Bug Screen 0.36 Bug Screen 0.38 Bug Screen a X❑ [X] X❑ ❑❑ ❑ ❑ El El El El ❑ ❑ ❑ ❑ ❑ ❑ El El El 1:1 ❑ ❑ ❑ ❑ ❑❑ ❑ ❑ ❑❑ D N1 1 X❑ ❑ ❑ D El El Run_ Initiation Time: 11115/02 16:52:23 Run Code: 1037407943 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R 11/15/2002 Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments ('Antral FiirnacP 80% AFUE Ducts in Attic 4.2 Setback Casita Cooling Equipment Minimum Type (air conditioner, Efficiency heat pump, evap. cooling) (SEER) Split Air Conditioner 12.0 SEER (attic, etc.) Duct Thermostat Location / R -Value Type Comments 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features a California Code of Regulations, and the administrative re overall design responsibility. The undersigned recognize and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Name: ,PDVE,+v4 ra0 Title/Firm: Gi+epaK�— HDI,41FS Address: I Ro *W—eII1 Telepho O, c Lic. #: Enfor Name Address: Telephone: performance specifications needed to comply with Title 24, Parts 1 and 6 of the ations to implement them. This certificate has been signed by the individual with t compliance using duct sealing and TXV's requires installer testing and certification Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 68-255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-2046 �► 2 Agency re) (date) (signat v (date) �EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:4 of 13 External Rated 1 Tank Energy Facts 1 WATER HEATING SYSTEMS Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type ' Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features a California Code of Regulations, and the administrative re overall design responsibility. The undersigned recognize and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Name: ,PDVE,+v4 ra0 Title/Firm: Gi+epaK�— HDI,41FS Address: I Ro *W—eII1 Telepho O, c Lic. #: Enfor Name Address: Telephone: performance specifications needed to comply with Title 24, Parts 1 and 6 of the ations to implement them. This certificate has been signed by the individual with t compliance using duct sealing and TXV's requires installer testing and certification Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 68-255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-2046 �► 2 Agency re) (date) (signat v (date) �EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:4 of 13 i Certificate of Compliance: Residential (Addendum) CF -1 R Casita 11/15/2002 Project Title !; Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "Casita" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Desiqn(see C -2R) - Verify ThE!rmal Mass: 363 sqft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field i Run Initiation Time: 11/15/0216:52:23 Run Code: 1037407943 EnergyPro 3.1 By EnergySoft I User Number: 2655 Job Number: Page:5 of 13 Mandato Measures Checklist: Residential (Page 1 of 2) MF -1 R Mandatory ( 9 NOTE: Lowrise residential buildings subject to the Standards must cIontain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considereld by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere: in the documents or on this checklist only. ❑1 § 150(f): Special infiltration barrier installed to comply with Section DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT and Gas Logs. Building Envelope Measures 1. Masonry and factory -built fireplaces have: + nce with ASHRAE, SMACNA or ACCA. 1✓ '§150(.): Minimum R-19 ceiling insulation. a. Closeable metal or glass door ❑ §1500): Pipe and Tank Insulation 150(b): El§ 150(b): Loose fill insulation manufacturer's labeled R -Value! (,//4 I✓ c. Flue damper and control li Minimum R-13 wall insulation in wood framed walls lor equivalent U -value in metal frame walls (does 2. No continuous burning gas pilots allowed. not apply to exterior mass walls). insulation or R-16 combined int: mal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. ❑ "§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. 5. Cooling system piping below 55 degrees F. insulated.) ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no v EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 13 greater than 2.0 perm/inch. h §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. / I✓ ❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditi fined spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label i with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. / 3. Exterior doors and windows weatherstripped; all joints Ind penetrations caulked and sealed. V ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and i 16 only. I J ❑1 § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. I ✓ ❑ §150.(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: + nce with ASHRAE, SMACNA or ACCA. 1✓ a. Closeable metal or glass door ❑ §1500): Pipe and Tank Insulation b. Outside air intake with damper and control 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. c. Flue damper and control li 2. First 5 feet of pipes closest t i water heater tank, non -recirculating systems, insulated (R-4 or greater) 2. No continuous burning gas pilots allowed. insulation or R-16 combined int: mal/extemal insulation. Space Conditioning, VVlater Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. I ❑§150(h): Heating and/or cooling loads calculated in accord + nce with ASHRAE, SMACNA or ACCA. 1✓ ❑§150(i): Setback thermostat on; applicable heating and/ r cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest t i water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined int: mal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated.) 6. Piping insulating between heating source and indirectihot water tank. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shnwn elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT I Space Conditioning, Water Heating and Plumbing System Measures: (continued) J `§ 150(m): Ducts and Fans I I 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or,UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned ,air. Joints and seams of duct systems and their components shall not be I j sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. I 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building ; i cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be 1 i compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back graft or automatic dampers. I 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. I 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, I equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 114: Pool and Spa Heating Systems and Equipment Fi r f operating instructions no electric resistance 1. Certified with 78 /o thermal efficiency, on-off switch, weatherp o0 op g , iheating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. ia. At least 36" of pipe between filter and heater for future solar heating. I b. Cover for outdoor pools or outdoor spas. 1 3. Pool system has directional inlets and a circulation pump time switch. a §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no / continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria i Lighting Measures i LJJ §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall belcontrolled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. !/ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of / 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. L V 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R 1111512.13102 Prcject Title Date La_Q.uinta_— -- — — Project Address [Building Permit#II-s.uJoTrn_,_l.nc.— _ (760 324-2046lan Check/DateDocumentation Author Telephone ComDuteLRerfo.Cman_Ce 5 ield Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.27 1.07 0.20 Space Cooling 3432 34.51 -0.18 Domestic Hot Water 0..00 0.00 0.00 Totals 35.59 35.58 0.01 BUILDING COMPLIES GENERAL INFORMATION LX�j Slab Floor Conditioned Floor Area: 363 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 20.4% Number of Dwelling Units: 0.25 Total Conditioned Volume: 3,267 Number of Stories: 1 Slab Floor Area: 363 BUILDING ZONE INFORMATION # of Thermostat _Zone Name _ Floor Area Volume Units Zone Type Type Casita _ _ 3.63 —3,262 —0.25_ Conditioned— —Setback_ Vent Hgt. Area —� ___n/a Solar OPAQUE SURFACES . Act. Gains Tvne Area U -Fac.. Azm. „Tilt Y / N Form 3 Reference. Location / Comments Computer Method Summary (Part 2 of 3) C -2R Casita 11/15/2002 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments Windov.%Eront_p0lssU -20.0_ _OUZO_ -0..3.6_ _270_ _9.0. B.eSter-Buat.-Windows Casita _L 2 Window Front(Nest) 24.0 0.270 0.21 270 90 Therma Tru Doors Casita 3 Window Rear (East) 20.0 0.570 0.36 90 90 Better Built Windows Casita 4 Window Rear (East) 10.0 0.570 0.38 90 90 Better Built Windows Casita INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd, Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen _ 0.76 5.0 4.0 2.0 0.1 2.0 2.0 2 Bug_Screen _ 0.76 8.0 3.0 4.0 0.1 4.0 4.0 3 Bug Screen _ 0.76 5.0 4.0 2.0 0.1 2.0 2.0 _ 4_, Bug_Screen _ 0.76 4.0 2.5 2.0 0.1 2.0 2.0 R n ni iation Time: 1.1/1S 19Z15L52:23 Run CoAt: 1037407943 E�CrgyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:9 of 13 Comauter Method Suimmary (Part 3 of 3) C -2R Casita _ _ 11/15/2002 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, HeAyyweight _ __3.63 _3_&0 _28. 0_.9.8. n1a 0. _C.asitaJ_Slab on_Grad.e PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab_P re ime(er 10 --Q,7,50.0_ 0 Casit� HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE:/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnac_e__ 80% AFUE Du&s in ttic 4.2 ----5gtbaGK— -aceta Pipe Insul. Hydronic Piping Pipe System Name• Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air �Qpddioner IZjQ SEER Ducts in Attic 4.2— melba-ck Casita _ WATER HEATING SYSTEMS Ratedl Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Casita 11/15/2002 Pfoject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation Submitted. Plan I Field The HVAC System "Casita" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 363 sgft Exposed Slab Floor, 3.50" thick at Casita HERS Required Verification.. These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field i EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 11 of 13 HVAC SYSTEM HEAPING AND COOLING LOADS SUMMARY iPROJECT NAME _ Casita SYSTEM NAME Casita Number of System jHeating System Output per System Y_Total Output (Btuh Output (Btuh/sgft) JISYSTEM LOAD 1i1 IIS 37,000: j Total Room Loads 37,0001! Return Vented Lighting Return Air Ducts —lll Return Fan Cooling System j Output per System 18,000 1. Total Output (Btuh) 18,000 Total Output (Tons) 1.51 Total Output (Btuh/sgft) 49.61 Total Output (sgftrron) 242.0 'I Ventilation i Supply Fan II Supply Air Ducts TOTAL SYSTEM LOAD �i DATE 11/15/2002 FLOOR AREA 363 COIL COOLING PEAK J1COILHTG.PEA7K. CFM Sensible Latent 11CFMI Sensible 664 6,677 796 1391 5,656 Oi ' 283 0 334 0 01 01 0 0; o 01 ! i 0 283 334 7,3451 796 6,222 lAir System —��i HVAC EQUIPMENT SELECTION CFM per System I 895; ---- --- !II!CARRIER 38HDC01832 I 9,6621 7,456 37,000 Airflow (cfm) 895i.I: Airflow (cfm/sgft) 2.4711 Airflow (cfm/Ton) 596.711 Total Adjusted System Output I �, Outside Air (%) 0.0 i (Adjusted for Peak Design Conditions) L 9 662 7,456 3500 i Outside Air (cfm/sgft) 0-001' TIME OF SYSTEM PEAK Aug 2pm Jan 12 am 1 Note: values above given at ARI conditions I . EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 69.7°F 69.7 OF 108.3°F F S 1 A' D Outside Air 0 cfm i Supply Fan Heating Coil 895 cfm 69.7 of ICOOLING SYSTEM PSYCHROMETRICS 1111.0 / 77.4 of 78.3 168.8 of Outside Air . 4' n cfm Supply Fan Cooling Coil 895 cfm 78.3/68.8 °F 1 l I upp y Ir. ucts 108.0 of i ROOMS 70.0 OF Return Air Ducts I airstream Temperatures at 78.3/68.80F M 68.3/65.50F �, Return Air Ducts '� Supply Air Ducts 68.6 / 65.6 of 62.9°i° R.H. ROOMS 78.0 / 68.7 OF EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page: 12 of 13 ROOM LOAD SUMMARY PROJECT NAME DATE Casita 11/15/2002 SYSTEM NAME FLOOR AREA Casita 363 Rwulvl LVMLJ JVlrllrll'1f�� ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE1 LATENT CFM SENSIBLE LATENT 11 CFM SENSIBLE Casita Casita 1 664 6,6771 796 664 6,677 796 139 5,656 EnergyPro 3.1 By Energysoft User Number: 2655 Job Number. Page: 13 of 13