Loading...
08-0315 (AR) Title 24TITLE 24 REPORT Title 24 Report for: Alex and Diana Londos. 79-090 Ladera Dr. La Quinta, Ca 92253 * 08 -315 Project Designer: Jorge L. Garcia 74-210 Alessandro Dr. Unit A Palm Desert, Ca 92260 760.272.9222 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTR CTION DA Report Prepared By: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Number: Ig021208 Date: 2/12/2008 FEB 19 2008 U The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: Ig021208 User Number: 5732 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 7 9 EnergyPro 4.4 by EnergySoft Job Number: Ig021208 User Number: 5732 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R AIPx and Diana I nnftns _ 2/1?/ 008 Project Title Date 7q-nc)n I adera nr La Quinta Project Address Building Permit # Santiann I nnP�-(�rampn (760) 485 8927 Doc'me, ation A thor Telephone Plan Check/Date FnPrnVPrn .A Climate 7pnc 15 Field Check/Date Complia ce Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.38 0.64 1.75 Space Cooling 107.23 106.34 0.89 Fans 14.65 14.35 0.30 Domestic Hot Water 33.33 33.33 0.00 Pumps 0.00 0.00 0.00 Totals 157.60 154.66 2.94 Percent better than Standard: 1 ao/ Building Type: [] Single Family ❑ Addition ❑ Multi Family [J Existing + Add/Alt Building Front Orientation: (S)180 deg Fuel Type: Natural Gas Fenestration: Area: 67 ft2 Avg. U: 0.47 Ratio: 14.2% Avg. SHGC: 0.34 BUILDING ZONE INFORMATION Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Zone Name Floor Area Volume Units Zone Type HVAC System 917 9,170 n 46 _- Cnnriffitmoneri HVAr Cystem 9S4; 9,58 0 54 rnnditinnPri Thermostat Type setback— s Pt ha rk 473 ft2 217 ft2 0 ft2 473 ft2 10.0 ft 1.00 1 Vent Hgt. Area —2 n —2 n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Rnof VWnd 717 n 049 X19 R_n 0 --n 18 ® ❑Existing ni-A4 Existing Wall Wnnd 1g9 n 11n R_11 R_n 0 An 9Q ® ❑Existing ng -A9 Existing Rnnf Wnnd 956 _0_025 R-38 R -nn _0 1 IN ❑NPw 01-AlR Add itinn Wall Wpnd 199 nj9 R_13 R -n n 1Rn _g0 IN ❑New 11_glA� Mod 147 Addition Wall —0102 R_13 R-00 22090 ®❑New 09 -AR Addition Wall Wnnd 177 0102 R_13 R_n 0 an q ®❑ New n9 -A.1 Additinn F ❑ El F-1 ❑❑ F-1 F-1 El Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Alex and Diana Londos 2/12/2008 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments J_ 1Clfinrtnw Right (E)4Q n 510 NFR(: 03 NFRC An --q()- New Gpnaral Aluminum Company FYicting 2 Window Right (E) 4.0 0.510 NFRC 0_34 NFRC 90 90 New General Aluminum Company Existing 3 Window Right (E) 4.0 0.510 NFRC 0_34 NFRC 90 90 New General Aluminum Company Existing 4 Window Front (S) 20.0 0.510 NFRC 0_34 NFRC 180 90 New General Aluminum Company Addition -5-- Window Left 15.0 0.510 NFRC 0_34 NFRC 270 90 New General Aluminum Company Addition -5-- Window Left (y)[j 20.0 0_360 NFRC 0_35 NFRC 270 90 New Jeld-Wen, Steel Fr Dr. Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 6-7 3.0 10.0 0 1 10.0 10.0 THERMAL MASS FOR HIGH MASS DESIGN Run Initiation Time: 02/12/08 10:52:40 Run Code: 1202842360 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page:4 of 10 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 217 3.50 _28 0_98 0 26-A1 Existing Existing / Slab on Grade Concrete, Heavyweight 256 3.50 28 0_98 0 26-A1 New Addition / Slab on Grade Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 52 None No Insulation 26-A1 New Addition Run Initiation Time: 02/12/08 10:52:40 Run Code: 1202842360 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page:4 of 10 Certificate Of Compliance: Residential • (Part 3 of 4) CF -1 R Alex and Diana Londos Rated 2/12/2008 Project Title Ducts Location Heating Cooling Location Date Tested? HVAC SYSTEMS Attic 4.2 Existing No HVAC System Ducted Ducted Attic 6.0 New Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 7846 AFUE Split Air Conditioner 8.9 SEER Existing Setback HVAC System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Rated Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 4.2 Existing No HVAC System Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water. Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst (Btu/hr) (gal) Status or RE Loss (%) Ext Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation . COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Jorge L. Garcia Address: 74-210 Ales andro Dr. Unit A Palm Dese 260 Telephone: 760.27 2 . #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: nature) (date) Documentation Author Name: SLO Title/Firm: Santiago Lopez-Ocampo Address: P.O. Box 1018 La Quinta. CA 92247 hone: (4 50) 485-8927 • (signature) (da e Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Alex and Diana Londos 2/12/2008 Project Title - Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adenuary of thn � i i was: .#:_ • , -- -- - ._.,__.... ....,, ....a.U-1—aauvn auunnuea. Plan Field The Roof "R-38 Roof w/Radiant Barrier" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 217 sqft Exposed Slab Floor, 3.50" thick at Living HIGH MASS Design - Verify Thermal Mass: 256 sqft Exposed Slab Floor, 3.50" thick at Addition HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS Drovider using approved testinn and/Or nn mr varieratifhnrrc • .. ..------�------• --....__..................... Plan Field The HVAC System "HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page:6 of 10 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). b. outside air intake with damper and control, flue damper and control ❑ ❑ •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X 1. Masonry and factory -built fireplaces have: § 1500): Water system pipe and tank insulation and cooling systems line insulation. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El El 11CF-6R ❑ Form: 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and InfiltratioNExfiltration Controls. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑x ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ Page:7 of 10 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑' length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ . 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - DESCRIPTION applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ® ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ © ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensors) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page:8 of 10 4 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE Alex and Diana Londos 2/12/2008 SYSTEM NAME FLOOR AREA HVAC Svstem ':)17 TE Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM FSensible Supply Air Ducts C7 4,269 566 48 2,043 0 110.0 of Heating 858 293 0 0 0 0 Oil 0 0 Return Air Ducts 0 DOLING SYSTEM PSYCHROMETRICS 0 858 293 5 986 566 2 628 HVAC EQUIPMENT SELECTION Default FAU/AC 1984 - 1991 1 0 0 Total Adjusted System Output 1 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 pm I Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 70.OoF 110.0 OF Supply Air Ducts Outside Air 0 cfm 110.0 of Heating Coil ROOMS 70.0 of 70.0 OF I Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 78.0/62.3OF 55.0/53.7OF Supply Air Ducts Outside Air 0 cfm Cooling Coil 55.0 / 53.7 OF 41.2% R.H. ROOMS 78.0/62.2 ° F 78.0 62.2 OF Return Air Ducts L I EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page:9 of 10 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE Alex and Diana Londos 2/12/2008 SYSTEM NAME FLOOR AREA HVAC System 256 Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Btuh/sqft) 125.0 Cooling System Output per System 18,000 Total Output (Btuh) 18,000 Total Output (Tons) 1.5 Total Output (Btuh/sqft) 70.3 Total Output (sgft/Ton) 170.7 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 3.12 Airflow (cfm/Ton) 533.3 Outside Air Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 6,7551 576 6,6617 HVAC EQUIPMENT SELECTION YorkCZB1811.PS8Al2N40. 9,743 7,516 32,000 Total Adjusted System Output g 743 7,51 s 32,000 (Adjusted for Peak Design Conditions) . TIME OF SYSTEM PEAK Aug2;M] Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.5 OF 69.50F 107.OoF Supply Air Ducts Outside Air 0 cfm 106.5oF Supply Fan Heating Coil 800 cfm ROOMS 70.0 of 69.5 °F 1% Return Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 11.0/77.60F >---I Outside Air 0 cfm 78.6/69.2 of 78.6/69.2OF 78.6/69.3OF . 67.2/65.5OF �1 Supply Fan Cooling Coil 800 cfm h Return Air Ducts `i Supply Air Ducts 67.8/65.70F 64.2% R.H. ROOM) 78.0/69.0 OF EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig021208 Page: 10 of 10 1