Loading...
08-0965 (AR) Title 24TITLE 24 REPORT `Title 24 Report for: THOMAS & DIANE RICHARDS RESIDENCE 80-645 LA DOCENA TRAIL, La Quinta, Ca 92253 Project Designer: Ochoa Design Associates 73-626 Highway 111 Palm Desert, Ca 92260 760.773.6605 Report Prepared By: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Number: Ig060408 JUL 2 2 2008 Date: ay 7/9/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: lg06O4O8 User Number: 5732 F TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary I 2 1 2 3 12 14 15 EnergyPro 4.4 by EnergySoft Job Number: Ig060408 User Number: 5732 Certificate Of Compliance: Residential Existing Floor Area: (Part 1 of 4) CF -1 R THOMAS R DIANE __R CHAR.DS_R.E.S_I.DE.NCE Project Title 1 A DOCENA TRAIL, l Quinta 0 ft2 Slab on Grade Area: 7/912008 Date 80-645 a Project Address 11.3 ft Number of Dwelling Units: Building Permit # ';I a�Z_ rn 1 (760) 485-8927 ;QQ npe DocuumenYation Abthor Telephone Plan Check/Date FnPrgVPro Compliance Method CA Climate 7nne 15 Climate Zone 1 Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.64 2.96 2.68 Space Cooling 109.04 81.71 27.33 Fans 14.64 11.19 3.45 Domestic Hot Water 6.54 6.54 0.00 Pumps 0.00 0.00 0.00 Totals l 135.87 102.41 33.46 Percent better than Standard: 24.6% Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition [j Existing + Add/Alt (N) 0 deg Natural Gas Area: 1,083 ft2 Avg. U: 0.35 Ratio: 20.6% Avg. SHGC: 0.27 Total Conditioned Floor Area: 5,261 ft2 Existing Floor Area: 4,315 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,261 ft2 Average Ceiling Height: 11.3 ft Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units UFAUUt bUlKrHLcb Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wond 99 n 095 -R-18 -R -0 n n 1 R Wall Wnnd 71 o n8q R_91 R -0.p_-0 _ A Wall Wnnd 35 n nsa R-71 R_n n gn An Wall- Wnnd 35 -0 069 -R21 R-0 0 97n -90 Rnnf Wood 875 n 049 R_1 q R-0 d _n I A Wall Wnnd 65 X02 -13 -0 0 n A Wall Wnnri 465 0 109 R_13 R_n n _9dQ0 Wall Wood 90 0102 X13 R-00 135 -90 Wall Wond q7 n109 R_13 R_n n lan mil Wall Wnnd 70 n 1n9 R_11 R_n n 999 _90 Wall Wood 188 0102 -R-13 R-0 0 - 97n 90 Rnnf Wnnd 89 _n 025 -R-38 -0 Q -D 18 Wall Wnnd 84 n n63 R21 R_n n qn gn Wall Wnnd 18 n 063 R-91 R -n n 775 Afl Wall Wood 54 X63 X21 R_n n 180 An Wall Wnnd 18 n nFg X91 R -n iL -995_ An Rnnf Wond 1 954 n 049 R-19 _R=0 0 0-18 Wall Wood 418 Q02 -R-13 -R-0 0 x-90 M111 Wond- 905 _0 102 R_13 _R-0 0 An A Wall Wnnd 147 _n 102 -13 R -n n 180 An Wall Wnnd 48 0102 R_13 R_n n 97n A Rnnf Wnnd 553 n n4q R_1 q RA n _0 1 R Wall Wnnd 78 n nsg R_91 R_n n 135 A Wall Wond 900 _0 063 R_91 R_n n 18n A Wall- Wnnd 76 _n 069 -R21 R-0 0 - 995 gn Zone Type Conditioned CnnditinnPd Conditioned Conditioned Thermostat Type shark SPthark Sethack Sethack Vent Hgt. Area 2 -nla -2 n/a -� n/a _2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments EnerovPro 4.4 by EnergvSoft IUser Number: 5732 Job Number: lg06O4O8 Page:3 of 18 Certificate Of Compliance: Residential ft2 (Part 1 of 4) CF -1 R THOMAS _& DIANE RICHARDS Project Title 8171-645 1 DOCENAJRAII RESIDENCE I Ql Raised Floor Area: 0 7/9/2008 Date ,4 Project Address a j*nt2 ft2 Average Ceiling Height: Building Permit # antiagn I gpez-nsa n 1.00 (760) 485-8927 , Documen ation A thor Telephone Plan Check/Date FnPrPrn Complig6ce Method CA Climate 7onp I Climate Zone I Field Check/Date .TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.64 2.96 2.68 Space Cooling 109.04 81.71 27.33 Fans 14.64 11.19 3.45 Domestic Hot Water 6.54 6.54 0.00 Pumps 0.00 0.00 0.00 Totals 135.87 102.41 33.46 than Standard: Building Type: [jd Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition [J Existing + Add/Alt (N) 0 deg Natural Gas Area: 1,083 ft2 Avg. U: 0.35 Ratio: ' 20.6% Avg. SHGC: 0.27 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt wall Wood 170 n 069 R_91 R_n n 970 _9p Rnof Wnnd 1 019 X49 R-1 2 R-0 0 — 0 1 Wall Wnnd 197 0109 R_13 R -o n ng Wall Wood 18 —0109 X2-13 —R -o n go q Wall Wnnd 51 0109 X13 R_n n 77n cin Rnnf Wnnd 79ri n 073 _$_38 R -Q 0 _�_ 1 Wall Wood 971 n nF9 R-71 R_n n ng door asP 74 n 5no Nnne IRA) 0 —0 g0 Wall Wnnd An 0 069 R_91 R_n n gIL-9I1 Wall Wnnd 1u n nsg R-91 —00 X80 A Wall Wnnd 175 () 069 R_91 R_n n 770 An Roof Wood 1 159 _n 095 X33_R-00.X 1A Wall Wnnd 181 X02 R_13 R -n 0 n gn Wall Wnnd 95 0 102 R_13 R_n n An gn Wall Wnnd 7Fin n 1n? _@_13 11-970 A l Total Conditioned Floor Area: 5,261 ft2 Existing Floor Area: 4,315 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,261 ft2 Average Ceiling Height: 11.3 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Thermostat Vent Units Zone Type Type Hgt. Area Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig060408 Page: 4 of 18 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 2 5 Window Skylight Window Front Front Left (N) 144 n 19; NFRC 09 NFRr n_ ) New Pozzi WUndnwc (N) 0.5 0.480 NFRC 0_37 NFRC 0 18 New 10" Solatube Curved Prismatic (E) 16.0 0.650 NFRC 0_48 NFRC 90 90 Existing_WECK. GLASS BLOCK 8x8x4 7nne 1 Zone 1 Zone 1 4 Window Left (E) 16.0 0.650 NFRC 0_48 NFRC 90 90 Existing WECK, GLASS BLOCK 8x8x4 Zone 1 5 Window Left (SE) 20.0 0.350 NFRC0 29 NFRC 135 90 Altered Pozzi Windows Zone 1 5 Existing Existing 0.790 116_A 0.70 116.8 Double Metal Clear ore -altered for above Z Window Rear (S) 84.3 0.350 NFRC 0_29 NFRC 180 gQAltered Pozzi Windows Zone 1 8 Existing 69 0.790 116-A 0_70 116-B Double Metal Clear pre -altered for above 5 10 u 12 13 14 Window Fx6cting Window Window Window Window Rear Right Rear Rear Rear (SZO 90.0 _0.35pNFRQ-0..29 NFRC 995_ qQAltered _Pozzi Windows 27.90116-A _07Q 116.8 Double Metal Clear (M_ 4.0 03.59NFRQ Q29 NERC 970 90 New Pozzi Windows (SW) 10.0 0.350 NFRC0 29 NFRC 225 90 New Pozzi Windows (S) 488 19 NFRC J129 NERC. 180 _0- New Pozzi Windows (SW) 10.0 0.350 NFRC0 29 NFRC225 90 New Pozzi Windows Zone 1 pre -altered for above Zone 1 Zone 2 lone 2 Zone 2 15 Window Front (N) 60.0 0.320 NFRC 0_24 NFRC 0 90 Altered Pozzi Doors Zone 2 10 Existing 0.790 116-A 0.70 116-B Double Metal Clear pre -altered for above 17 Window Front (N) 32.3 0.350 NFRC 0_29 NFRC 0 90 Altered Pozzi Windows Zone 2 18 Existing Status 0.790 116-A 0_70 116-B Double Metal Clear pre -altered for above 1R Window Front (N) 3n 0 035 NF$C__0.29 NFRC 0 _gQ Altered Pozzi Windows Zone 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # ' Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 None 1.00 3 Bug Screen -0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 8.0 2.5 3.0 0.1 2.0 9.0 7 Bug Screen 0.76 8.0 9.5 3.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 2.5 3.0 0.1 2.0 2.0 11 12 Bug Screen Bug Screen 13 Bug Screen 14 Bug Screen 15 Bug Screen 0.76 0.76 7.5 1.3 0.76 7.5 6.5 0.76 7.5 1.3 0.76 17 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN 12.0 0.1 12.0 12.0 12.0 0.1 12.0 12.0 12.0 0.1 12.0 12.0 Type Area Thick. Heat Inside (so (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 29 3.50 28 0_98 0 26-A1 New Zone 1 / Slab on Grade Concrete, Heavyweight 186 3.50 28 0_98 0 26-A1 Existing Zone 1 / Slab on Grade Concrete, Heavyweight 690 3.50 28 0_98 2 26-A1 Existing Zone 1 / Slab on Grade Concrete, Heavyweight 69 3.50 28 0_98 0 26-A1 New Zone 2 / Slab on Grade Concrete, Heavyweight 213 3.50 28 0_98 0 26-A1 Existing Zone 2 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 07/09/08 06:08:23 Run Code: 1215608903 EnergyPro 4.4 by Energysoft User Number: 5732 Job Number: Ig060408 Page:5 of 18 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Am. Tilt Stat. Glazing Type Comments 2Q Fxisting 0790 116_A 07 116-R nnuhlP Metal Caaar nrc-altered for ahnva 21 Window Left (E) 9.5 0.350 NFRC 0_29 NFRC 90 90 Altered Pozzi Windows Zone 2 22 Existing 0.790 116-A0.70 116-B Double Metal Clear pre -altered for above 23 Window Rear (S) 150.0 0.320 NFRC 0_24 NFRC 180 90 Altered Pozzi Doors Zone 2 24 Existing 0.790 116-A 0.70 116.6 Double Metal Clear pre -altered for above 25 Window Left (,SE) 17.5 0.350 NFRC 029 NFRC 135 90 New Pozzi Windows Zone 3 2fi Window Rear (_S) 11.0 0_350 NFRC 0_29 NFRC 180 _,q0_ New Pozzi Windows Zone 3 27 Window Rear (S) 48.0 0.320 NFRC 0_24 NFRC 180 90 New Pozzi Doors Zone 3 2$ Window Rear (S) 15.4 0.350 NFRC 029 NFRC 180 __qQ New Pozzi Windows Zone 3 28 Window Rear (_S) 547 0.350 NFRC 029 NFRC 180 __M New Pozzi Windows Zone 3 _3Q Window Rear . (_S) 11.0 0.350 NFRC 0.29 NFRC 180 90 New Pozzi Windows Zone 3 31 Window Rear (S) 48.0 0.320 NFRC 0.24 _NFRC 180 90 New Pozzi Doors Zone 3 _a2 Window Rear (S) 29-, n 39 NFRC Q2A NFR(' 180 _.Q New Pozzi nonrc Zone 3 33 _Window Rear iS) 45.0 0.320 NFRC 0.24 NFRC 180 90 New Pozzi Doors Zone 3 34 Window Rear (S) 22.5 0.320 NFRC 0_24 NFRC 180 90 New Pozzi Doors Zone 3 -35 Window Rear (So 17.5 0.350 NFRC0 29 NFRC 225 90 New Pozzi Windows Zone 3 ,IL Window Front (N) 44.9 0.350 NFRC 0_29 NFRC. 0 90 Altered Pozzi Windows Zone 3 37 Existing 0.790 116-A 0_70 116-B Double Metal Clear pre -altered for above .3$ Window Front (N) 4.6 0.350 NFRC 029 NFRC 0 q0_ New Pozzi Windows Zone 4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 21 Bug Screen 0.76 23 Bug Screen 0.76 10 0 16.0 18.0 0"1 2.0 2.0 25 Bug Screen 0.76 26 Bug Screen 0.76 1.8 6.0 14.0 0.1 4.0 4.0 27 Bug Screen 0.76 8.0 6.0 14.0 0.1 4.0 4.0 28 Bug Screen 0.76 11.8 8.4 14.0 0.1 4.0 4.0 29 Bug Screen 0.76 6.5 8.4 14.0 0.1 4.0 4.0 30 Bug Screen 0.76 1.8 6.0 14.0 0.1 4.0 4.0 31 Bug Screen 0.76 8.0 6.0 14.0 0.1 4.0 4.0 32 Bug Screen 0.76 .33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug screen 0.76 36 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 1.041 3.50 28 0_98 2 26-A1 Existing Zone 2 / Slab on Grade Concrete, Heavyweight 553 3.50 28 0498 0 26-A1 New Zone 3 / Slab on Grade Concrete, Heavyweight 1.032 3.50 28 0_98 0 26-A1 Existing Zone 3 / Slab on Grade Concrete, Heavyweight 223 3.50 28 0_98 2 26-A1 New Zone 4 / Slab on Grade Concrete, Heavyweight 72 3.50 28 _0.98 0 26-A1 New Zone 4 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 07/09/08 06:08:23 Run Code: 1215608903 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig060408 Page:6 of 18 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date FENESTRATION SURFACES Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. True Cond. Location/ # Type ` Area LI -Factor" SHGCZ Azm. Tilt Stat. Glazing Type Comments M Winrinw I aff (F) . 94 n 019 NFR(` X24 NERC 0 -9L NPw Pn»i nnnrc 7nnP 4 40 Window Rear (S) 11.2 0.350 NFRC 0_29 NFRC 180 90 New Pozzi Windows Zone 4 41 Window Rear (S) 20.0 0.320 NFRC 0_24 NFRC 180 90 New Pozzi Doors Zone 4 42 Window Rear (S) 40.0 0.320 NFRC 0_24 NFRC 180 90 New Pozzi Doors Zone 4 93- Window Rear (S) 20.0 0.320 NFRC 0_24 NFRC 180 90 New Pozzi Doors Zone 4 A4 Window Right (_V14 33.0 0.350 NFRC 0.29 NERC 270 90 New Pozzi Windows Zone 4 9!Z Skylight Front (N)_ 0.5 0-480 NFRQ 0.37 NFRC 0 18 New 10" Solatube Curved Prismatic Zone 4 46 Window Front (N) 10.5 0.350 NFRC 0_29 NFRC 0 90 Altered Pozzi Windows Zone 4 _4Z Existing 0-790116_A _QIQ 116_6 Double Metal Clear ore -altered for above A.$ Window Front (N)L 150 0-35NERC0-29 NFRC 0 Pi0 Altered -Pozzi Windows Zone 4 _4,Q Existing 116-A Q24 116.8 Double Metal Clear ore -altered for above -279 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt.. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 Comments Concrete, Heavyweight 673 3.50 28 0_98 2 40 Bug Screen 0.76 Existing Zone 4 / Slab on Grade 41 Bug Screen 0.76 8.0 2.5 8.0 0.1 8.0 8.0 42 Bug Screen 0.76 8.0 5 A,n _0 80 80 43 Bug Screen 0.76 8.0 2.5 8.0 01 8.0 8.0 _ 44 Bug Screen 0.76 45 None 1.00 46 Bug Screen 0.76 _ 48 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 673 3.50 28 0_98 2 26-A1 Existing Zone 4 / Slab on Grade Concrete, Heavyweight 480 3.50 28 0_98 026 -Al Existing Zone 4 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run InitiationTime: 07/09/08 06:08.23 Run Code: 1215608903 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig060408 Page:7 of 18 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date HVAC SYSTEMS HVAC DISTRIBUTION Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff- Type Eff Status Type HVAC System - Zone 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Existing Setback HVAC System - Zone 2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Existing Setback HVAC System - Zone 3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Altered Setback HVAC DISTRIBUTION WATER HEATING SYSTEMS Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System - Zone 1 Ducted Ducted Attic 4.2 Existing No HVAC System - Zone 2 Ducted 'Ducted Attic 4.2 Existing No HVAC System -Zone 3 Ducted Ducted Attic 4.2 Existing No Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext Standard Gas 50 gal or Less Small Gas No Pipe Insulation : 2 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: SLO Title Z60.773.6 e;sin Associates Title/Firm: Santiago Lopez-Ocampo ddressi hwa 111 Address: P.O. Box 1018 ert Ca 92260 La Quinta, CA 92247 TelephoLic. M hone: 0 485-8927 yam-, °g&= V • • `I0 (sign re) (date) (signature) Is (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Run Initiation Time: 07/09/08 MUM Run Code• 1215608903 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: lg06O4O8 Page:8 of 18 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type pre -altered for above Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback HVAC System -Zone 4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Altered Setback pre -altered for above Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heatinq Coolinq Location R -Value Status Tested? HVAC System -Zone 4 Ducted Ducted Attic 4.2 Altered No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # . HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: SLO Title/Firm: Ochoa Design Associates Title/Firm: Santiago Lopez-Ocampo Address: 73-626 Highway 111 Address: P.O. Box 1018 Palm Desert, Ca 92260 Telephone: 760.773.6605 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) (signature) (date) La Quinta, CA 92247 hone: (7 60) 485-8927 oft • (signature) • (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted.Ply pied The Roof "R-38 Roof Attic w/Radiant Barrier' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential ManuE I. The Roof "R-38 Roof w/Radiant Barrier' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 29 sqft Exposed Slab Floor, 3.50" thick at Zone 1 - Addition HIGH MASS Design - Verify Thermal Mass: 186 sqft Exposed Slab Floor, 3.50" thick at Zone 1- Existing HIGH MASS Design - Verify Thermal Mass: 690 sqft Covered Slab Floor, 3.50" thick at Zone 1- Existing HIGH MASS Design - Verify Thermal Mass: 69 sqft Exposed Slab Floor, 3.50" thick at Zone 2 - Addition HIGH MASS Design - Verify Thermal Mass: 213 sqft Exposed Slab Floor, 3.50" thick at Zone 2 - Existing HIGH MASS Design - Verify Thermal Mass: 1041 sqft Covered Slab Floor, 3.50" thick at Zone 2 - Existing HIGH MASS Design - Verify Thermal Mass: 553 sqft Exposed Slab Floor, 3.50" thick at Zone 3 - Addition HIGH MASS Design - Verify Thermal Mass: 1032 sqft Exposed Slab Floor, 3.50" thick at Zone 3 - Existing HIGH MASS Design - Verify Thermal Mass: 223 sqft Covered Slab Floor, 3.50" thick at Zone 4 - Addition HIGH MASS Design - Verify Thermal Mass: 72 sqft Exposed Slab Floor, 3.50" thick at Zone 4 - Addition HIGH MASS Design - Verify Thermal Mass: 673 sqft Covered Slab Floor, 3.50" thick at Zone 4 - Existing HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field I EneravPro 4.4 by EneravSoft User Number: 5732 Job Number: lo06O4O8 Page:10 of 18 1 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies raacu vn uIc aucyuaa.y ul uio alrca:101 juwuucauun anu uucumemauon suumnaea. Plan Field HIGH MASS Design - Verify Thermal Mass: 480 sqft Exposed Slab Floor, 3.50" thick at Zone 4 - Existina HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a ueoe .. ..iAe.. A* .:. ....t _ . _:M .: 6_J_ Plan Field Q in Ini4in+inn Tirr - n71naina nc•na.74 0— Pa...l... 494 cenonn9 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig060408 Page:11 of 18 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE - MENT Building Envelope Measures § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ .§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). b. outside air intake with damper and control, flue damper and control ❑ Q �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ 0 1. Masonry and factory -built fireplaces have: § 1500): Water system pipe and tank insulation and cooling systems line insulation. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑x ❑ having an installed thermal resistance of R-12 or greater. b. outside air intake with damper and control, flue damper and control ❑ Q ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ N ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ • ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include a a ❑ ❑ CF -6R Form: 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain infiltration ❑ ❑X ❑ ❑ Coefficient (SHGC), and certification. EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: lg06O4O8 Page: 12 of 18 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ 0 ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: lg06O4O8 Page: 12 of 18 Mandatory Measures Summarv: Residential (Page 2 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ® ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ® ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. and have an output frequency no less than 20 kHz. ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies'with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. ' • § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ® ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms,garages, laundry rooms, and utility rooms luminaires less than 70 ft) OR by dimmer OR ❑ © ❑ shall be high efficacy (except closets are controlled a switch are controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ® ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Igo60408 Page: 13 of 18 Residential Kitchen Lighting Worksheet WS -5R THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts High Efficacy Quantity Watts Other Watts (1) 2 ft U -Tube TS Elec Yes No 39.0 x 8 = 312 or 1 42w Compact Fluorescent Tri /Quad 4 in Yes X No 46.0 x 9 = 414 or eo Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 726 B: 0 COMPLIES IF A>_ B YES ® NO 0 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig060408 Page: 14 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 SYSTEM NAME FLOOR AREA HVAC System - Zone 1 905 KS Number of Systems 1 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sqft) 0.0 Cooling System Output per System 1 Total Output (Btuh) 1 Total Output (Tons) 0.0 Total Output (Btuh/sqft) 0.0 Total Output (sgftrron) 1 ,860,000.0 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfm/sqft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 OF Outside Air 0 cfm 70.0 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Fsens 12,129 I CFM I Sensible 66 16,202 1,49 285 12,129 0 3,257 1,737 0 0 0 0 0 0 0 0 0 3,2571 1,737 22,7151 1 49 15 604 Default FAU/AC 1992 - 2005 1 0 0 Total Adjusted System Output 1 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pmt I Jan 12 am PSYCHROMETRICS (Airstream Ter 70.0°F . 110.001' Heating Coil res at Time of �% Return Air Ducts 4 Supply Air Ducts 110.0 of ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 78.0/62.3°F 55.0/53.7°F Supply Air Ducts Outside Air 0 cfm Cooling Coil 55.0 / 53.7 of 41.2% R.H. ROOMS 78.0/62.2 o F 78.0 / 62.2 o F Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: lg06O4O8 Page:15of 18 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 SYSTEM NAME FLOOR AREA HVAC System - Zone 2 1,323 26.0 OF Outside Air 0 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 775 18,980 1,815 380 16,171 0 3,815 2,316 0 0 0 0 0 0 0 0 0 3,815 2,316 26 609 1 815 1 20 803 HVAC EQUIPMENT SELECTION Default FAU/AC 1992 - 2005 1 0 0 Total Adjusted System Output1 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug2 prn I Jan 12 am PSYCHROMETRICS (Airstream Ter 70.0°F ■ 110.0°F Heating Coil �% Return Air Ducts `i Supply Air Ducts 110.OoF ROOMS 70.0 of (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak1 11.0 / 77.6 OF �y Outside Air 0 cfm 78.0/62.2 ° F 78.0/62.30F . 55.0/53.7OF Cooling Coil 4.4 by EnergySoft User Number: 5732 h Return Air Ducts `; Job Number: Supply Air Ducts 55.0/53.7OF 41.2% R.H. ROOM) 78.0/62.2OF 16 of 18 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 SYSTEM NAME FLOOR AREA HVAC System - Zone 3 1,585 EATING S' 26.0 OF >---A Outside Air 0 cfm 68.8 of 68.8 of Supply Fan 1800 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible Supply Air Ducts Outside Air 968 19,738 2,016 388 16,242 0 58.8 / 56.3 of 3,967 2,327 0 0 0 0 0 0 0 80.1/64.2 0 F 0 0 3,967 2,327 1 27,673 2,016 20 895 HVAC EQUIPMENT SELECTION YorkCZB60.PS8CN100.2000cfm 44,631 5,610 80,000 Total Adjusted System Output 44631 5,610 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 m Jan 12 am RICS (Airstream Ter 68.8 OF 110.50F Heating Coil res at Time of Heati 41, Supply Air Ducts 109.3 of ROOMS 70.0 of Return Air Ducts I ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peakl I 111.0/77.6OF 80.1 64.2 OF 80.1 /64.2OF 56.8/55.5OF Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 58.8 / 56.3 of 1800 cfm ROOMS 45.1% R. H. 80.1/64.2 0 F 78.0 / 63.5 OF Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: lg06O4O8 Page: 17 of 18 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THOMAS & DIANE RICHARDS RESIDENCE 7/9/2008 SYSTEM NAME FLOOR AREA HVAC System - Zone 4 1,448 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sqft) 55.2 Cooling System Output per System 48,500 Total Output (Btuh) 48,500 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 33.5 Total Output (sgft/Ton) 358.3 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.10 Airflow (cfm/Ton) 395.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 747 15,967 2,111 1 285 13,542 0 2,817 1,940 0 0 0 0 0 0 0 0 0 2,817 1 1,940 21.600 2 111 17 422 YorkCZB48. PS8CN1 00.1 600cfm 39,816 2,715 80,000 Total Adjusted System Output 39,816 2,715 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 pm Jan 12 am ATING SYSTEM PSYCHROMETRICS (Airstream Ter 26.0 OF 68.9 OF 68.9 OF 115.8 OF Outside Air 0 cfm Supply Fan Heating Coil 1600 cfm 68.9 of :OOLING SYSTEM PSYCHROMETRICS (Airstream Tem 11.0/77.6 OF 79.7163.8 OF 79.7/63.90F ■ 310� Outside Air 0 cfm 79.7/63.8 ° F at Time of Heatina Pea )% Return Air Ducts 4 ratures at Time 56.3/55.0 OF Supply Fan Cooling Coil 1600 cfm h Return Air Ducts `i Supply Air Ducts 114.7oF ROOMS 70.0 of Supply Air Ducts 57.9/55.6OF 44.6% R.H. ROOMS 78.0/63.3 OF EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: lg06O4O8 Page:18 of 18