BELC2014-1058 Title 24I
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Engler Residence
57-615 Coral Mountain Court
La Quinta, CA 92253
Project Designer:
Walling & McCallum Limited
45-190 Club Drive
Indian Wells, CA 92210
(760) 360-0250
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
Job Number:
Date:
9/24/2014
BUILD _SFE
AFF
FOR CONY
The EnergyPro computer program has been used to perform the calculations summarized in tlj is�c&pliance,
• authorized by the California Energy Commission for use with both the Residential and Nonresidential -M&
This program developed by EnergySoft, LLC —www.energysoft.com.
r.,e.....o... c ti., c..e.,..c..a 11—nt.... h— a74'3 oA4A nn eiron.cn.0 in•
BY.
i has agoroyal_And is
17,
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
9/24/2014
Project Address
57-615 Coral Mountain Court La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,187
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
m Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
• Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 7,187 Radiant Barrier New
Wall Wood Framed
R-21 6,072 New
Slab Unheated Slab -on -Grade
None 7,187 Perim = 736' New
FENESTRATION U- Exterior
Orientation Area(fo Factor SHGC Overhang Sidefins Shades Status
Front (NE) 361.9 0.390
0.32 none none Bug Screen
New
Left (S) 937.1 0.390
0.32 none none Bug Screen
New
Rear (tM 282.6 0.390
0.32 none none Bug Screen
New
Right (NW) 60.6 0.390
0.32 none none Bug Screen
New
Right (N) 205.3 0.390
0.32 none none Bug Screen
New
Front (E) 80.7 0.390
0.32 none none Bug Screen
New
Left (SE) 45.0 0.390
0.32 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 14.5 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 14.5 SEER Setback
New
3 Central Furnace 80% AFUE
Split Air Conditioner 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
D.u,c.
Cooling Duct Locatiorr11TnpR,-U', 'U15 at s
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, qntol m niNG 88.(BAFETY Cru „i T•
HVAC 2 Ducted
Ducted Attic, Ceiling Ins,vented 0 P8 Op)p / F Flew
HVAC 3,4 & 5 Ducted
Ducted Attic, Ceiling Ins, vented ®� 181.0 CTl&
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
2 Large Gas 100
0.80 All Pipes /nsd r, -!
ew---
EnergyPro 5.1 by EnergySoft User Number: 6712
Run Code: 201409-24720:50:51 ID:
Page 3 of 37
•
n
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Engler Residence
Building Type m Single. Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
9/24/2014
Project Address
57-615 Coral Mountain Court La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,187
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity f Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGG Overhang Sidefins Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Fumace 80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct LocationR-Vake77—,
s
HVAC 6 Ducted Ducted Attic, Ceiling Ins, ve to ed+I ()r 8.A U " Je
zt nt G & SA
V oppt ED
WATER HEATING FOR CONSTRUC
Qty. Type Gallons Min. Eff Distribu ion Status
BY
I
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24720:50:51 ID:
Page 4 of 37
0
C]
•
i
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name Building Type m Single Family ❑ Addition Alone Date
Engler Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 924/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Bradford -White 100 Gal is a non-NAECA large storage gas water heater. Verify DHW details.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 1,008.0 ft' Covered Slab Floor, 3.500" thick at Master Suite
HIGH MASS Design - Verify Thermal Mass: 224.0 ft' Exposed Slab Floor, 3.500" thick at Master Suite
The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 409.0 ft' Covered Slab Floor, 3.500" thick at North Bedroom
HIGH MASS Design - Verify Thermal Mass: 102.0 ft' Exposed Slab Floor, 3.500" thick at North Bedroom
HIGH MASS Design - Verify Thermal Mass: 355.0 ft' Covered Slab Floor, 3.500" thick at South Bedroom
HIGH MASS Design - Verify Thermal Mass: 120.0 ft' Exposed Slab Floor, 3.500" thick at South Bedroom
IThe HVAC System HVAC 3, 4 & 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must
have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design -Verify Thermal Mass: 664.0 ft' Covered Slab Floor, 3.500" thick at Living Zone
HIGH MASS Design - Verify Thermal Mass: 3,348.0 ft' Exposed Slab Floor, 3.500" thick at Living Zone
The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Carrier 24ANB648158CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB648158CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB660158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 3, 4 & 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display
duct leakage meets the specified criteria.
The Cooling System Carrier 24ANB636158CVX070 includes credit for a 13.0 EER Cond
of the correct Condenser.
The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge
6 T
I verificatiornand dia.Tnob tesfrhgpis required t9 ver
e-., n fir• -� � T
?bser:)'A r#ifiei)4_ �aterrrrias't fe/b-v r y he i
IndicatorF'OR yCONSTRUCTION
;a tion and diagnostic testing is required to verify th
^TE BY
fy that
tallation
duct
e5of37
C
C.
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family 1:1Addition Alone
❑ M-ulti Family ❑ Existing+ Addition/Alteration
Date
1912412014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 471.0 ft2 Covered Slab. Floor, 3.500" thick at Guest Suite
HIGH MASS Design - Verify Thermal Mass: 486.0 ftz Exposed Slab Floor, 3.500" thick at Guest Suite
The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
GIT`,( OF LA QU N I A
11114
E.lUIL a & SA E+ , - .
A 10.0QQ®I
FOR CONSTRUCTION
Ene Pro 5-1 by EnerqySoft User Number: 6712 Run Code: 2014-09-24720:50:51 ID: Page 6 of 37
•
•
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Engler Residence❑
Multi Family ❑ Existing+ Addition/Alteration
1912412014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/V- r
Space Heating 4.70 2.84 1.86
Space Cooling 53.68 45.55 8.13
Fans 10.68 13.52 -2.83
Domestic Hot Water 5.08 3.42 1.66
Pumps 0.00 0.00 0.00
Totals 74.14 65.33 8.81
Percent Better Than Standard: 11.9%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NE) 1,846 443
Fuel Available at Site: Natural Gas (SE) 3,013 982
Raised Floor Area: 0 (SK9 1,375 283
Slab on Grade Area: 7.187 (NM 1,811 266
Average Ceiling Height: 11.8 Roof 7,187 0
Fenestration Average U -Factor: 0.39 TOTAL: 1.973
Average SHGC: 0.32 Fenestration/CFA Ratio: 27.5%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation. is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc, .
9/14/2014
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and r- g izes-drat-com� ce s g uc��de ign,
duct sealing, verification of refrigerant charge, insulation installation qu lit y�anib,�iiliinge v�op°e�sealing�reglai e
installer testing and certification and field verification by an approved H RS��a�ffpjNG SAP PT.
Designer or Owner (per Business & Professions Code) AR _ E
Company Walling & McCallum Limited R CO° IRU ON
Address 45-190 Club Drive Name Ke vi 16800 018^d to/ 2414
6►i.4 \%%44.4
Id
City/State/Zip Indian Wells, CA 92210 Phone (760) 360-0250 DATE Si ed BY—License #— Date
7—
EnergyPro 5.1 by EnemySoft User Number., 6712 RunCode: 201409-24T20:50:51 ID: Pae 7 of 37
C
C
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface
Type Area
U Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,232
0.026 R-38
270
0 New 4.2.1-A9
Zone 1 Master Suite
Wall
189
0.069 R-21
0
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
61
0.069 R-21
45
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
147
0.069 R-21
90
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
238
0.069 R-21
180
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
2351
0.069 R-21
225
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
171
0.069 R-21
270
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
2261
0.069 R-21
315
90 New 4.3.1-A6
Zone 1 Master Suite
Slab
1,008
0.730 None
0
180 New 4.4.7-A1
Zone 1 Master Suite
Slab
224
0.730 None
0
180 New 4.4.7-A 1
Zone 1 Master Suite
Roof
511
0.026 R-38
270
0 New 4.2.1-A9
Zone 2 Bedroom North
Wall
115
0.069 R-21
0
90 New 4.3.1-A6
Zone 2 Bedroom North
Wall
206
0.069 R-21
45
90 New 4.3.1-A6
Zone 2 Bedroom North
Wall
30
0.069 R-21
225
90 New 4.3.1-A6
Zone 2 Bedroom North
Wall
205
0.069 R-21
315
90 New .4.3. I -A6
Zone 2 Bedroom North
Slab
409
0.730 None
01
180 1 New 4.4.7-A1
Zone 2 Bedroom North
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
38.5 0.390 NFRC
0.32 1 NFRC
45 New
Double Non -Metal Tinted
Zone 1 Master Suite
2
Window
27.0 0.390 NFRC
0.32 1 NFRC
180 New
Double Non -Metal Tinted
Zone 1 Master Suite
3
Window
54.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 1 Master Suite
4
Window
27.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 1 Master Suite
5
Window
27.0 0.390 NFRC
0.32 NFRC
270 New
Double Non -Metal Tinted
Zone 1 Master Suite
6
Window
20.0 0.390 NFRC
0.32 NFRC
315 New
Double Non -Metal Tinted
Zone 1 Master Suite
7
Window
30.0 0.390 NFRC
0.32 NFRC
315 New
Double Non -Metal Tinted
Zone 1 Master Suite
i 8
Window
5.3 0.390 NFRC
0.32 NFRC
0 New
Double Non -Metal Tinted
Zone 2 Bedroom North
9
Window
10.4 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Zone 2 Bedroom North
10
Window
16.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Zone 2 Bedroom North
11
Window
8.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Zone 2 Bedroom North
12
Window
5.3 0.390 NFRC
0.32 NFRC
315 New
Double Non -Metal Tinted
Zone 2 Bedroom North
13
Window
36.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 2 Bedroom South
14
Window
48.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 2 Bedroom South
15
Window
24.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 2 Bedroom South
16
Window
36.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 2 Bedroom South
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76r
-n
11
Bu Screen
0.76
I (a
E-7' "`
12
Bug Screen
0.76
rt
T. -I ry
13
Bu Screen
0.76
14
Bu Screen
0.76
R (,
IN
15
JBug Screen
1 0.76
16
JBug Screen
1 0.76
DATE _ -----
FnergyPro
5.1 by Ene Soft User Number: 6712 RunCode: 2014-09-24T20:50:51 ID:
Page 8:o:0:7
•
LJ
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
102
0.730 None
0
180 New 4.4.7-A1
Zone 2 Bedroom North
Roof
475
0.026 R-38
270
0 New 4.2.1-A9
Zone 2 Bedroom South
Wall
205
0.069 R-21
180
90 New 4.3.1-A6
Zone 2 Bedroom South
Wall
130
0.069 R-21
270
90 New 4.3.1-A6
Zone'2 Bedroom South
Slab
355
0.730 None
0
180 New 4.4.7-A1
Zone 2 Bedroom South
Slab
120
0.730 None
0
180 New 4.4.7-A1
Zone 2 Bedroom South
Roof
4,012
0.026 R-38
270
0 New 4.2.1-A9
LoungrelraplKitlGyrnlOffic
Wall
396
0.069 R-21
0
90 New 4.3.1-A6
Loun e/Ta /Kit/G m/Offlc
Wall
319
0.069 R-21
45
90 New 4.3.1-A6
Loun e/Ta /KIUG m/Offic
Wall
193
0.069 R-21
90
90 New 4.3.1-A6
Lounge/Ta /Kit/G m/Offic
Wall
398
0.069 R-21
135
90 New 4.3.1-A6
LoungelTap/Kit/Gym/Offlc
Wall
480
0.069 R-21
180
90 New 4.3.1-A6
Loun e/Ta /Kit/G m/0ffic
Wall
680
0.069 R-21
270
90 New 4.3.1-A6
Loun e/Ta /Kit/G m/Offic
Wall
149
0.069 R-21
315
90 New 4.3.1-A6
Loun e/Ta /Kit/G m/Offic
Slab
664
0.730 None
0
180 New 4.4.7-A1
Loun e/Ta /Kit/G m/Offic
Slab
1 3,3481
0.730 None
1 0
180 New 4.4.7-A1
Loun e/Ta /Kit1G m/0fflc
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
17
Window
5.3 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 2 Bedroom South
18
Window
16.0 0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Zone 2 Bedroom South
19
Window
40.5 0.390 NFRC
0.32 NFRC
0 New
Double Non -Metal Tinted
Loun e/Ta /Kit/G m/Office
20
Window
54.0 0.390 NFRC
0.32 NFRC
0 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
21
Window
40.5 0.390 NFRC
0.32 NFRC
0 New
Double Non -Metal Tinted
Lounge/Tap/KitlGym/Office
22
Window
45.0 0.390 NFRC
0.32 NFRC
0 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
23
Window
60.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/Tap/Kit1Gym/0ff1ce
24
Window
9.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/Tap/KitlGym/Office
25
Window
60.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/Tap/KitlGym/Office
26
Window
60.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/0ff1ce
27
Window
16.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
28
Wndow
24.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/7`ap/Kit1Gym/0ffice
29
Window
16.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Loun e/Ta /Kit/G mlOffice
30
Wndow
8.0 0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Lounge/Tsp/Kit/Gym/Office
31
Window
71.5 0.390 NFRC
0.32 NFRC
90 New
Double Non -Metal Tinted
Lounge/Tap/KitlGym/Office
32
Window
9.0 0.390 NFRC
0.32 NFRC
135 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin
Len HgL LExt RExt Dist Len I
Right Fin
H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
,
24
Bug Screen
0.76
y r Fy ri111
25
Bug Screen
0.76
R v_��
L
26
Bu Screen
0.76
f3UII WIC'^
27
Bug Screen
0.76
1f4 C? Q
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.761
1
31
lBug Screen
0.761
1
32
Bu Screen
0.76
DAT
EnergyPro
5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24720:50:51 ID:
Page 9 of 37
•
11
C�
J
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
912412014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor CavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
957
0.026 R-38
270
0 New 4.2.1-A9
Guest Suite
Wall
266
0.069 R-21
0
90 New 4.3.1-A6
Guest Suite
Wall
431
0.069 R-21
90
90 New 4.3.1-A6
Guest Suite
Wall
225
0.069 R-21
180
90 New 4.3.1-A6
Guest Suite
Wall
481
0.069 R-21
135
90 New 4.3.1-A6
Guest Suite
Wall
437
0.069 R-21
180
90 New 4.3.1-A6
Guest Suite
Wall
48
0.069 R-21
45
90 New 4.3.1-A6
Guest Suite
Slab
471
0.730 None
0
180 New 4.4.7-A1
Guest Suite
Slab
486
0.730 None
0
180 New 4.4.7-A1
Guest Suite
FENESTRATION SURFACE DETAILS
ID
TvPe
Area LI -Factor'
SH C2
Azm Status
Glazing Type
Location/Comments
33
Window
16.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/TapJKitJGym/Office
34
Window
38.5 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
35
Window
42.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Loun e/Ta /Kit/G m/Office
36
Window
154.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/rap/Kit/Gym/Office
37
Window
38.5 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
38
Window
28.9 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
39
Window
93.5 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
40
Window
38.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
41
Window
18.4 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
42
Window
48.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
43
Window
18.4 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
44
Window
8.0 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
45
Window 1
48.0 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Loun e/Ta /Kit/G m/Office
46
Window
8.0 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Lounge/rap/Kit/Gym/Office
47
lWindow 1
71.5 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
48
lWindow 1
22.0 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt RExt Dist Len H t Dist Len H t
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
39
Bug Screen
0.76
40
Bug Screen
0.76
41
Bug Screen
0.76
Ca
"` I I` 1
i V I r
42
Buq Screen
0.76
l
_ - .., .. •. c, n C
r FP
43
lBuq Screen
0.76
44
JBuq Screen
0.76
45
By Screen
0.76
46
Bug Screen
0.76
47
Bug Screen
0.76
48
Bug Screen
0.76
I
EnergyPro
5.1 by EnergySoft User Number: 6712
RunCode: 2014-09-24T20:50:51 ID:
Pae 10 of 37
0
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
LI -Factor'
SHGC2
Azm Status
Glazing Type
Location/Comments
49
Window 18.7
0.390 NFRC
0.32 1 NFRC
270 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
50
Window 60.5
0.390 NFRC
0.32 NFRC
270 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
51
Window 13.6
0.390 NFRC
0.32 NFRC
270 New
Double Non -Metal Tinted
Loun e/1 a /Kit/G m/Office
52
Window 5.3
0.390 NFRC
0.32 NFRC
270 New
Double Non -Metal Tinted
Lounge/TaphOUGym/Office
53
Window 5.3
0.390 NFRC
0.32 NFRC
315 New
Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
54
Window 20.0
0.390 NFRC
0.32 NFRC
0 New
Double Non -Metal Tinted
Guest Suite
55
Window 4.6
0.390 NFRC
0.32 NFRC
90 New
Double Non -Metal Tinted
Guest Suite
56
Window 4.6
0.390 NFRC
0.32 NFRC
90 New
Double Non -Metal Tinted
Guest Suite
57
Window 20.0
0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Guest Suite
58
Window 29.6
0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Guest Suite
59
Window 36.0
0.390 NFRC
0.32 NFRC
135 New
Double Non -Metal Tinted
Guest Suite
60
Window 16.0
0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Guest Suite
61
Window 48.0
0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Guest Suite
62
Window 16.0
0.390 NFRC
0.32 NFRC
180 New
Double Non -Metal Tinted
Guest Suite
63
Window 36.0
0.390 NFRC
0.32 NFRC
45 New
Double Non -Metal Tinted
Guest Suite
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt RExt Dist Len H t Dist Len H t
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
55
Bug Screen
0.76
_
56
Bug Screen
0.76
r
-LJA
�, , P X I -T-
57
Bug Screen
0.76
0
t
U U C B F71
58
Bug Screen
0.76
1
„< 1.1 r kid Q. P
59
Bug Screen
0.76
60
Bug Screen
0.76
61
Bug Screen
0.76
r-iti r m
I- I ION
62
Bug Screen
0.76
v
-IC
63
Bug Screen
0.76
+rRV
EnergyPro
5.1 by EnergySoft User Number: 6712 Run Code: 2014-09-24720:50:51 /D:
Pae 11 of 37
•
•
•
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Engler Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area
New Existinq Altered Removed Volume Year Built
HVAC 1 Master Suite
1,232
13,552
HVAC 2 North Bedroom
511
5,110
South Bedroom
475
4,750
HVAC 3,4 & 5 Living Zone
4,012
51,354
HVAC 6 Guest Suite
957
10,049
Totals 7,187 0 01 0
HVAC SYSTEMS
System Name Qt . HeatingType
Min. Eff. CoolingType Min. Eff. Thermostat Type Status
HVAC 1
1 Central Furnace
80% AFUE Split Air Conditioner 14.5 SEER Setback
New
HVAC 2
1 Central Furnace
80% AFUE Split Air Conditioner 14.5 SEER Setback
New
HVAC 3,4 & 5
3 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC 6
1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION
System Name
Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
m New
HVAC 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
m New
HVAC 3,4 & 5 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
HVAC 6 1 Ducted
Ducted Attic, Ceiling Ins, vented 1 8.01
New
WATER HEATING SYSTEMS
S stem Name
aty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White 100 Gal
2
Large Gas
All Pipes Ins
90,000
100
0.80
0.00%
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM PIPING
Control
Hot Water Piping Length
(ft)�
.i
0:3
a c
CITY OF LA ( UIN
BUILDING &SAF �' .-NDE
S, stemtNam_e,("1\ i Len ih
_A
T'Pi,e
Diarr2eter
Insul.
Thick.
aty. HP
Plenum Outside Buried
01
❑ i
Y_
❑
EnergyPro 5.1 by EnergySoft
User Number: 6712
Run Code: 2014-09-24720:50:51 ID:
Pae 12 of 37
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R
Project Name
ngler Residence
Date
9/24/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM Ell 677-95(2000) when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
e uipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
1 50 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated be oon hRatiag-sourc&arad-indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A. 1 I I NIT .
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systeims X1'5 psi! meet§ th -re ui &merit"§ of S nd" rds Table
123-A. ! B1 JUDING & SA ETY DEP .
1NOW: Insulation is protected from damage, including that due to sunli ht moisture d' ui :ment.m int& Once, a d wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includ s a vaor ree'M%a ` o�iS,e - 6—se irely in
conditioned space. 1. II r511��
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
DATE BY
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-09-24T20:50:51 /D: Page 13 of 37
�7�
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Engler Residence
9/24/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
160(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
4150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system• and all p!_Lmaaytly installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, nd t i y, roomy re h, iab etfac�c� �rtid�e910 fled by a
a MMA
manual -on occupant sensor. (� LA t A
§150(k)9: Permanently installed lighting that is internal to cabinets shall us nMLP. reCae &0&a`ts%grEoVgr � it far f of of
illuminated cabinet. {
gHPiR VEE)
FOR CONSTRUCTION
nAa F BY
EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2014-09-24T20:50 a1 /D Page 14 of 37
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
ngler Residence
1912412014
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with.a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
OF QFETY
BUILDINGSAFETY
JDE
APPRO�ED
FOR
E__-
BY
EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24T20:50:51 /D: Page 15 of 37
4
r
L
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Engler Residence
Date
9/24/2014
System Name
HVAC 1
Floor Area
1,232
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 647
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
71,000
12,866
1,775 388
16,809
Total Output Btuh
71,000
0
Output Btuh/s ft
57.6
743
826
Cooling System
o
0
Output per System
47,000
0
0 0
0
Total Output Btuh
47,000
0
1,775
0
Total Output Tons
3.9
1 743
826
Total Output Btuh/s ft
38.1
Total Output s ft/Ton
314.6
14,352
18,461
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ANB648/58CVX090 33,326 4,227
71,000
Airflow cfm/s ft
1.30
Airflow cfm/Ton
408.5
1 71,000
Jan 1 AM
Outside Air % 0.0%
Total Adjusted System Output 33,326 4,227
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
72 OF
72 OF 113 OF ^^ 113 OF
Heating Coil Supply Fan
1,600 cfm 113 ° F
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112178 OF
Outside Air
0 cfm
70 / 58 OF
70 158 °F 51 / 50 OF 51 150 OF
t
c Supply Fan BUILDING & = Y DEPT.
Cooling Coil 1 51 / 50 °F
1,600 cfm SPP �{'
FOA CONS-87,UDCTI y00
70 / 58 OF
L --- Y
EnergyPro 5.1 by EnergySoff
User Number: 6712 Run Code: 201409-24T20:50:51 /D: Page 16 of 37
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Engler Residence
Date
9/24/2014
System Name
HVAC 2
Floor Area
986
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 701 13,933
Return Vented Lighting 0
Return Air Ducts 804
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 804
TOTAL SYSTEM LOAD 15,542
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output perSystem
71,000
1,660 320
13,926
Total Output Btuh
71,000
Output Btuh/s ft
72.0
684
Cooling System
0
Output perSystem
47,000
0 0
0
Total Output Btuh
47,000
1,660
0
Total Output Tons
3.9
684
Total Output Btuh/s ft
47.7
Total Output s ft/Ton
251.7
15,294
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ANB648/58CVX090 33,429 4,107
71,000
Airflow cfm/s ft
1.62
Airflow cfmrron
408.5
Outside Air°io
0.0%
Total Adjusted System Output 33,4291 4,107
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
71,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
10
Outside Air
0 cfm
72 OF
72 OF 113 °F 113 OF
Heating Coil Supply Fan o
1,600 cfm 113 F
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
70 158 OF
70/58°F 51 /50°F 51 /50°F
c
Cooling Coil Supply Fan grJi�pING & SAFETY DEPT. 51 / 50 OF
1,600 cfm
oa 00
FOR CONS'l ri CT t , M
70 / 58 OF
EnergyPro 5.1 by EnergySoff
User Number: 6712 RunCode: 2014-09-24720:50:51 /D: Page 17 of 37
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ngler Residence
Date
9/24/2014
System Name
HVAC 3,4 & 5
Floor Area
4,012
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 3
COIL
CFM
Total Room Loads 3,064
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 89,000
57,080
5,527 1,339
58,326
Total Output Btuh 267,000
0
Output Btuh/s ft 66.6
3,295
2,866
Cooling System
01
0
Output per System 57,500
0
0 0
0
Total Output Btuh 172,500
0
5,527
0
Total Output Tons 14.4
3,295
2,866
Total Output Btuh/s ft 43.0
Total Output s ft/Ton 279.1
1 63,670
64,059
Air System
CFM per System 2.000
HVAC EQUIPMENT SELECTION
Airflow cfm 6,000
Carrier 24ANB660/58CVX110 118,383 20,578
267,000
Airflow cfm/s ft 1.50
Airflow cfm/Ton 417.4
Outside Air % 0-0%
Total Adjusted System Output 118,383 20,578
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
1 267,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Im
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF 113 OF 113 OF
^
Outside Air
0 cfm Heating Coil Supply Fan
113 OF
6,000 cfm
ROOM
72 OF 72 OF
4 3 .4 1
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 71 /59°F 52/51 OF 52/51 OF
c O - E�t qTAOutside Air 01. , �NJZU
61
0 cfm Cooling Coil Supply Fan BUILDING & SAFETY DEPT,52 51 OF
6,000 cfm
APP os�X4&M
FOR CONSTR
71 / 59 OF 70 59 OF
j DATE B�'
EnergyPro 5.1 by EnergySolf User Number: 6712 RunCode: 2014-09-24720:150:51 /D: Page 18 of 37
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Engler Residence
9/24/2014
System Name
Floor Area
HVAC 6
957
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 1
COIL
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
CFM
Output per System 51,000
16,259
1,423 428
17,557
Total Room Loads 792
Total Output Btuh 51,000
0
Return Vented Lighting
Output Btuh/s ft 53.3
939
863
Return Air Ducts
Coolin S stem
0
0
Return Fan
Output per System 36,000
0
0 0
0
Ventilation 0
Total Output Btuh 36,000
0
0
Supply Fan
Total Output Tons 3.0
939
863
Supply Air Ducts
Total Output Btuh/s ft 37.6
Total Output s ftrron 319.0
1 18,136
1 19,282
TOTAL SYSTEM LOAD
1,423
Air System
CFM perSystem 1,200
HVAC EQUIPMENT SELECTION
Airflow cfm 1,200
Carrier 24ANB636/58CVX070 26,525 2,094
51,000
Airflow cfm/s ft 1.25
Airflow cfmfTon 400.0
Outside Air % 0.0%
Total Adjusted System Output 26,525 2,094
51,000
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 71 OF 111 OF 111 OF
fF
Outside Air
0 cfm Heating Coil Supply Fan
111 OF
1,200 cfm
ROOM Lo
71 OF 72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 71/58°F 50/49°F 50/49°F
QUINTA
c I
Outside Air A.
0 cfm Cooling Coil Supply Fan fg. 1 �9 -40VED 51 / 49 OF
1,200 cfm A ff—
FOR C N TR�CROOM 11
71 / 58 OF BYE—_70-1 8 OF
DATE ---- — --
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-09-24720:50:51 /D: Page 193
0
•
ROOM LOAD SUMMARY
Project Name Date
Engler Residence 9/24/2014
System Name Floor Area
HVAC 1 1,232
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name. Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Zone 1 Master Suite Master Suite 1 647 1Z8661 1,775 6471 12,8661 1,775 388 16,809
' Total includes ventilation load for zonal
PAGE TOTAL DA7
TOTAL•
= 647
_12,86 1-7-7-5
---388 16,809
--64.7
—1`2,�r6_6 1,775
388 16,809
ROOM LOAD SUMMARY
Project Name
Engler Residence
Date
9/24/2014
System Name
HVAC 2
Floor Area
986
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM
Sensible
Latent CFM Sensible
Zone 2 Bedroom North North Bedroom
1 280 5,563 853
280
5,563
853 148 6,453
Zone 2 Bedroom South South Bedroom
1 421 8,370 807
421
8,370
807 172 7,473
I
pi I
[�I
SAFE DE T.
e
ep r n
I I ETON
' Total includes ventilation load for zonal systems.
PAGE TOTAL
TOTAL
1 701
DAT
13,933
93
1,660 320 1,,926
—476601-3-2U 1 926
Ene Pro 5.1 by Ene Soft User Number: 6712
RunCode: 201409.24720:50:51
/D:
Page 21 of 37
•
0
ROOM LOAD SUMMARY
Project Name Date
Engler Residence 9/24/2014
System Name Floor Area
HVAC 3, 4 & 5 4,012
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult.CFM Sensible Latent CFM Sensible Latent CFM Sensible
Lounge/Tap/KiVGym/Office Living Zone 1 3,064 57,080 5,527 3,064 57,080 5,527 1,339 58,326
Total includes ventilation load for zonal
EnemyPro 5.1 by EnemySoft User N
'ut
PAGE TOTAL
TOTAL'
>014-09-24T20:5
3,064
57,080
5,527 1,339
326
p 0.64_
7,-0 —5,
527 --1,
5 , 326
22
•
ROOM LOAD SUMMARY
Project Name Date
Engler Residence 9/24/2014
System Name Floor Area
HVAC 6 957
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible I Latent CFM I Sensible I Latent I CFM Sensible
Guest Suite Guest Suite 1 1 7921 16,2591 1,423 7921 16,2591 1,4231 4281 17,557
. Total includes ventilation load for zonal
PAGE TOTAL
TOTAL'
11 792 16,2591 1,4231
42817,
55
16, 259 1 4
428
—�-7; 55
•
•
ROOM HEATING PEAK LOADS
Project Name
Engler Residence
Date
9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Floor Area 1,232.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
Btu/hr
R-38 Roof(R.38.2x14.16)
1,232.0
0.0260
46
= 1,473
R-21 Wall (W.19.2x6.16)
1,112.5
0.0690
46
= 3,531
Double Non -Metal Tinted
223.5
0.3900
46
= 4,010
= 4,600
Slab -On -Grade
pen .m = 137.0
0.7300
46
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
p13,615
�=j 3,195
through an interior surface
X 1,232 X
Area
_ rJ�l
r ae
� SAF�'
qjV�
r/ -6O$,
CONt
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
another took; I i
BUILDING
11.OQ X 0'x289
Height ��'c"R
Ceiling
TOTAL HOURLY HEAT LOSS FOR ROOM nATE ___ B 6,809
EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2014-09-24T20:50:51 /D: Page 24 of 37
•
F,
ROOM HEATING PEAK LOADS
Project Name
Engler Residence
Date
9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name North Bedroom
Floor Area 511.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
Btu/hr
R-38 Roof(R.38.2x14.16)
511.0
0.0260
46
= 611
R-21 Wall (W.19.2x6.16)
555.0
0.0690
46
= 1,762
= 807
Double Non -Metal Tinted
45.0
0.3900
46
Slab -On -Grade
perim = 58.0
0.7300
46
= 1,948
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
-
ODt l 5,128
46 T. 1,325
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
X 511 X
Area
anotheweee
1000 = IL0j3'18
Height ACHE
FOCI
A P ge
`a/ 6p A �q�--
. d L...Ai
CONSTRUCTION
TOTAL HOURLY HEAT LOSS FOR ROOM 6 453
IDATE __— BY
Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24T20:W F /D: Page 25 of 37
•
0
ROOM HEATING PEAK LOADS
Project Name
Engler Residence
Date
9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name South Bedroom
Floor Area 475.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
U -Value
X 0.0260
X 0.0690
X 0.3900
X 0.7300
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room CIV
,�-ING
10.00 X 0.318
Ceiling Height ACH'�
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FOR
AT °F
46 =
46 =
46 =
46 =
=
=
=
Btu/hr
R-38 Roof(R.38.2x14.16)
475.0
568
R-21 Wall (W.19.2x6.16)
334.7
1,062
Double Non -Metal Tinted
165.3
2,965
Slab -On -Grade
perim = 49.0
1,645
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
OF LF Totel1�
& SAFETY
f,6U�]F,,X �®1 F7-_
n 6 T -
CONSTRILM PION
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule , Air Sensible
Fraction
through an interior surface
X 475 X
Area
i 6,241
DE
6, = 1,232
TOTAL HOURLY HEAT LOSS FOR ROOM 473
DATE ---�—
EnerqyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24T20:50:51 . ID: Page 26 of 37
C
C�
ROOM HEATING PEAK LOADS
Project Name
Engler Residence
Date
9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living Zone
Floor Area 4,012.0 ft2
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
APP
A
FOR
AT °F
Btu/hr
R-38 Roof(R.38.2x14.16)
4,012.0
0.0260
46
= 4,798
= 8,298
R-21 Wall (W. 19.2x6.16)
2,614.4
0.0690
46
Double Non -Metal Tinted
1,308.6
0.3900
46
= 23,476
Slab -On -Grade
pen .m = 338.0
0.7300
46
= 11,350
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
o-� 4 ,923
ri
46 = 1,,403
I
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
X 4,012 X
Area
another roo
CITY
12.80 CITY
Height ACH
a e �Ot�lr
OF l,,,jL1
8)C, A
i
CONSTRUCTION
( TOTAL HOURLY HEAT LOSS FOR ROOM 58 26
DATE `---- BY
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24T20:50:51 Page 27 of 37
•
•
ROOM HEATING PEAK LOADS
Project Name
Engler Residence
Date
9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Suite
Floor Area 957.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X ----------
j
AT *F
46 =
46 =
46 =
46 =
=
=
=
=
=
Btu/hr
R-38 Roof(R.38.2x14.16)
957.0
0.0260
1,145
R-21 Wall (W 19.2x6.16)
1,455.2
0.0690
4,619
Double Non -Metal Tinted
230.8
0.3900
4,141
Slab -On -Grade
perim = 154.0
0.7300
5,171
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
anothe room' 6
BUILDING
10.f�50 X ��303
Heig't FA,�CFji
Page T to
& SAFE' °��
�= ,
1 -?61-.% 0 X Q"�
COiv I h V
15,075
6 = 2,481
,
Items shown with an asterisk (•) denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
X 957 X
Area
TOTAL HOURLY HEAT LOSS FOR ROOM nATE _ -- 17 557
EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2014-09-24720:50:51 /D: Page 28 of 37
•
•
C
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Engler Residence
1 9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,232.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) NO 1,232.0 X 0.0260 X 56.0 =
1,794
R-21 Wall (W. 19.2x6.16) (N) 189.0 X 0.0690 X 23.0 =
300
R-21 Wall (W. 19.2x6.16) (NE) 60.5 X 0.0690 X 29.0 =
121
R-21 Wall (W. 19.2x6.16) (E) 147.0 X 0.0690 X 33.0 =
335
R-21 Wall (W 19.2x6.16) (S) 238.0 X 0.0690 X 26.0 =
427
R-21 Wall (W 19.2x6.16) (SW) 235.0 X 0.0690 X 31.0 =
503
R-21 Wall (W. 19.2x6.16) (W) 17.0 X 0.0690 X 33.0 =
39
R-21 Wall (W. 19.2x6.16) (NW) 226.0 X 0.0690 X 30.2 =
471
X X =
Page Total
3,989
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area GLF
Btu/hr
Window (NE) 0.0 X 19.7 + 38.5 X 30.0 =
1,154
Window (S) 0.0 X 19.7 + 27.0 X 19.7 =
533
Window (S) 0.0 X 19.7 + 54.0 X 19.7 =
1,066
Window (S) 0.0 X 19.7 + 27.0 X 19.7 =
533
Window (W) 0.0 X 19.7 + 27.0 X 38.7 =
1,044
Window (NW) 0.0 X 19.7 + 20.0 X 30.0 =
599
Window (NW) 0.0 X 19.7 + 30.0 X 30.0 =
899
X + X -
X 1 +1 X -
Page Total
5,829
Internal Gain
Btu/hr
Occupants 1.0 Occupants X 230 Btuh/occ. =
230
Equipment 0.0 Dwelling Unit X 1,600 Btu =
0
Infiltration: 1.064 X 0.94 X 67.42 X 42 =
2,818
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ('`, , r, F-
12,866
t✓ I I Y �
Latent Gain BUILDING & SAFETY DEPT
Bt /hr
Occupants 1 0 Occupants X 2g0,, Igf gRoPc 0V
FOR CONSTRUCInfiltration:
4,771 X 0.94 X 67.42 X 0.00523=
ti:
Air Sensible CFM ELA AW
! DAr,E
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,775
EnemvPro 5.1 by EnemySoft User Number., 6712 RunCode: 2014-09-24720:50:51 /D: Page 29 of 37
•
C.
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Engler Residence
9/24/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
North Bedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area
511.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF,
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16)
(W) 511.0 X 0.0260 X 77.0 =
1,023
R-21 Wall (W 19.2x6.16)
(N) 114.7 X 0.0690 X 31.0 =
245
R-21 Wall (W. 19.2x6.16)
(NE) 205.6 X 0.0690 X 34.0 =
482
R-21 Wall (W. 19.2x6.16)
(SW) 30.0 X 0.0690 X 52.0 =
108
R-21 Wall (W. 19.2x6.16)
(NW) 204.7 X 0.0690 X 48.1 =
679
X X
X X
X X
X J X
Page Total
2,537
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
Window
(N) 0.0 X 23.6 + 5.3 X 23.6
= 125
Window
(NE) 0.0 X 23.6 + 10.4 X 35.5
= 369
Window
(NE) 0.0 X 23.6 + 16.0 X 35.5
= 568
Window
(NE) 0.0 X 23.6 + 8.0 X 35.5
= 284
Window
(NW) 0.01 X 23.6 + 5.3 X 52.9
= 280
X + X
X + X
X + X
X +1 X
Page Total
1 1,627
Internal Gain
Btu/hr
Occupants
1.0 Occupants, X 230 Btuh/occ. =
230
Equipment
0.0 Dwelling Unit X 1,200 Btu =
0
Infiltration: 1.064
X 0.94 X 27.96 X 42 =
1,169
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
5,563
Ct �F LA
Latent Gain
Occupants
: PT
1.0 Occupants X P-' i oNkgt$` o AFE
Btu/hr
Zoo
E®
Infiltration: 4,771
X 0.94 x 27.96 x o.00s23 = FOR CONSTRUCTION
653
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM DA I t ----
853
------
EnergyPro 5.1 by EnemySoft
User Number 6712 Run Code: 2014-09-24720:50:51 /D:
Page 30 of 37
C�
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7912412014
ate
Engler Residence
ROOM INFORMATION
DESIGN CONDITIONS
Room Name South Bedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area 475.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area
U -Factor CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) (W) 475.0 X 0.0260 X 77.0 =
951
R-21 Wall (W 19.2x6.16) (S) 204.7 X 0.0690 X 38.0 =
537
R-21 Wall (W 19.2x6.16) (W) 130.0 X 0.0690 X 55.0 =
493
X X =
X X =
X X =
X X =
X X =
X X =
Page Total 1
1,981
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area
GLF Area GLF
Btu/hr
Window (S)
0.0 X 23.6 + 36.0 X 30.7 =
1,105
Window (S)
0.0 X 23.6 + 48.0 X 30.7 =
1,473
Window (S)
0.0 X 23.6 + 24.0 X 30.7 =
736
Window (S)
0.0 X 23.6 + 36.0 X 30.7 =
1,105
Window (S)
0.0 X 23.6 + 5.3 X 30.7 =
163
Window (S)
0.0 X 23.6 + 16.0 X 30.7 =
491
X + X -
X + X -
X +1 X -
Page Total
5,072
Internal Gain
Btu/hr
Occupants 1.0 Occupants X
230 Btuh/occ. =
EA
Equipment 0.0 Dwelling Unit X
1,200 Btu =
Infiltration: 1.064 X 0.94 X 25.99 X 42 =
1,086
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
, r
8,370
CIT`( OF UA UU"N'
Latent Gaint:5l.vii_v�
/� DEPT.
e9d� V
& SAFE t 1
Btu/hr
Occupants 1.0 Occupants X
�n �
I( ,!iQ0- Bt chg/cfeC. / � =
200
Infiltration: 4,771 X 0.94 X 25.99
X 0.OP523 FOR CO�� iRucT�oN
607
Air Sensible CFM ELA
3! ,..•� BY
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
ter,
807
EnemvPro 5.1 by EnemySoft User Number. 6712 RunCode: 2014-09-24720:50:51 /D: Page 31 of 37
Cl
•
•
I RESIDENTIAL ROOM COOLING LOAD SUMMARY
Engler Residence
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
9/24/2014
ROOM INFORMATION
0.0260
DESIGN CONDITIONS
0.0690
Room Name
Living Zone
Outdoor Dry Bulb Temperature
112 OF
Floor Area
4,012.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Range:
34 OF
680.4
148.7
0.0690
33.0
0.0690
ODaaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
Area .
4,012.0
396.0
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
0.0260
56.0
0.0690
23.0
319.0
0.0690
29.0
192.5
398.0
0.0690
33.0
0.0690
31.0
479.8
0.0690
26.0
680.4
148.7
0.0690
33.0
0.0690
30.2
j
I=
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area GLF
Window
Window
Window
Window
Window
Window
Window
Window
Window
(N)
(N)
(N)
(N)
(NE)
(NE)
(NE)
(NE)
(NE)
Btu/hr
5,841
628
638
438
851
861
1,549
310
1 11,1181
0.0
X
X
X
X
X
X
X
X
X
19.7
+
+
+
+
+
+
+
+
40.5
X
X
X
X
X
X
X
X
X
19.7
=
=
=
=
=
=
=
=
=
0.0
19.7
54.0
19.7
0.0
19.7
40.5
19.7
0.0
19.7
45.0
19.7
0.01
19.7
60.0
30.0
0.0
19.7
9.0
30.0
0.0
19.7
60.0
30.0
0.0
19.7
60.0
30.0
0.0
19.71+1
16.01
1 30.0
Page Total
Internal Gain
Occu ants 2.0 Occupants X 230 Btuh/occ. _
Equipment 1.0 Dwelling Unit X 1,600 Btu =
Infiltration: 1.064 X 0.94 X 219.54 X 42 =
Air Sensible CFM ELA AT
Btu/hr
797
1,062
797
885
1,798
270
1,798
1,798
479
Btu/hr
1
1 9,1771
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM -A t -%i IIKITA 1 57,080
Latent Gain �i�i nir.IG & SAFETY DEPT -
MI to/hr
7�1Uv. IIt�'11
Occupants 2.0 Occupants X ,�?OO :, Btuli-70,0. V ED = 400
4 rs r
FOR CONSTRUCTION
Infiltration: 4,771 X 0.94 X 219.54 X 0.00523 = 5,127
Air Sensible CFM ELA AW 1
BY
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5.5271
9
•
9
G
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Engler Residence 1 9/24/2014
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Zone Outdoor Dry Bulb Temperature 112 OF
Floor Area 4,012.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranqe: 34 OF
ue Surfaces Orientation
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPnP_StratInn
Window
Window
Window
Window
Window
Window
Window
Window
Window
Internal Gain
Oriantatinn
(NE)
(NE)
(NE)
(E)
(SE)
(S)
(S)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
19.7
24.0
30.0
0.0
19.7
16.0
30.0
0.0
19.7
8.0
30.0
0.0
19.7
71.5
38.7
0.0
19.7
9.0
27.0
0.0
19.7
16.0
19.7
0.0
19.7
38.5
19.7
0.0
19.7
42.0
19.7
0.0
19.7
154.0
19.7
Page Total
is 2.0 Occupants X 230 Btuh/occ. _
nt ��]1.0 Dwelling Unit X 1,600 Btu =
Infiltration: 1.064 X 0.94 X 219.54 X 42 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
2.o Occupants X
Infiltration: 4,771 X 0.94 X 219.54 X
Air Sensible CFM ELA
& SAFETY DEPT .
2.00- .'Btf7h/oa .
rOR CONSTRUCTION
Btu/hr
rol I
719
479
240
2,765
243
316
760
829
3,041
Btu/hr
460
1,600
9,177
F57,080
to/hr
400
=1 1 5,127
DATE -_ BY
0
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7912412014
ate
Engler Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Zone Outdoor Dry Bulb Temperature 112 OF
Floor Area 4,012.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF
Opaque Surfaces Orientation
Area U -Factor CLTD'
X X =
X X
X X =
X X =
X X =
X X =
X X =
X X =
X X
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area GLF
Window
Window
Window
Window
Window
Window
Window
Window
Window
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(WM
(149
0.0
0.0
0.0
X
X
X
X
X
X
X
X
. X
19.7
+
+
+
+
+
+
+
+
+
38.5
X
X
X
X
X
X
X
X
X
19.7
=
_
c
_
_
_
c
=
c
19.7
28.9
19.7
19.7
93.5
19.7
0.0
19.7
38.0
19.7
0.0
19.7
18.4
19.7
0.0
19.7
48.0
19.7
0.0
0.0
19.7
18.4
19.7
19.7
8.0
0.0
19.7
48.0
H38.71
Page Total
Btu/hr
Gl l
760
571
1,847
750
363
948
363
309
1,856
7, 769
Internal Gain Btu/hr
Occupants 2.0 Occupants X 230 Btuh/occ. = 460
Eg ui ment 1.0 Dwelling Unit X 1,600 1 Btu = 1,600
Infiltration: 1.064 X 0.94 X 219.54 X 42 c 9.177
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 57,080
Latent Gain
CITY O It
t� si_v 91G & SAFETY DEP • B u/hr
Occupants 2.0 Occupants X 200 _Btuh/oec�� ®= 400
Infiltration: 4,771 X 0.94 X 216.54 X 0.005231 c FOR CONSfRUCTIOq51127
Air Sensible CFM ELA AW -r
BY
•
1�
u
C
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7912412014
ate
Engler Residence
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living Zone
Outdoor Dry Bulb Temperature
112 OF
Floor Area
4,012.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor.Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area
U -Factor CLTD'
Btu/hr
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area
GLF Area GLF
Btu/hr
Window
(lM
0.0 X 19.7 + 8.0 X 38.7 =
309
Window
(lM
0.0 X 19.7 + 71.5 X 38.7 =
2,765.
Window
(lM
0.0 X 19.7 + 22.0 X 38.7 =
851
Window
(WM
0.0 X 19.7 + 18.7 X 38.7 =
723
Window
(IM
0.0 X 19.7 + 60.5 X 38.7 =
2,340
Window
(K9
0.0 X 19.7 + 13.6 X 38.7 =
526
Window
(lM
0.0 X 19.7 + 5.3 X 38.7 =
205
Window
(NWAO
0.0 X 19.7 + 5.3 X 30.0 =
159
X + X -
Page Total
7,878
Internal Gain
Btu/hr
Occupants
2.0 Occupants X
230 Btuh/occ. =
460
Equipment
1.0 Dwelling Unit X
1,600 Btu =
1,600
Infiltration: 1.064
X 0.94 X 219.54 X 42 =
9,177
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
A
57,080
Latent Gain
1A
'lTy OF ,° I
I
to/hr
Occupants
2.9 Occupants X
p
5 ? !t!._t2oo�l�atu`hhio cY®P
400
Infiltration: 4,771
X 0.94 X 219.54 X 0.00523 = `4tj�� CONSIRUCTtON
5,127
Air Sensible
CFM ELA
AW
BYi
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
3 DATE ------
S-527
EnergyPro 5.1 by EnerqvSoft
User Number: 6712 Run Code: 2014-09-24720:50:51 /D: Page 35 of 37
4
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7912412014
ate
Engler Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Guest Suite Outdoor Dry Bulb Temperature 112 OF
Floor Area 957.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF
ODaaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wail (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
Orientation
(E) I
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
957.0
0.0260
77.0
266.0
0.0690
31.0
430.8
0.0690
44.0
662.4
0.0690
38.0
48.01
0.0690
43.0
48.0
0.0690
34.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area
Window
Window
Window
Window
Window
Window
Window
Window
Window
n
(N)
(E)
(E)
(S)
(S)
(SE)
(S)
(S)
(S)
0.0
X
X
X
X
X
X
X
X
X
23.6
+
+
+
+
+
+
+
+
+
20.0
0.0
0.0
0.0
0.0
0.0
0.0
23.6
4.6
23.6
4.6
23.6
20.0
23.6
29.6
23.6
36.0
23.6
16.0
0.0
0.0
23.6
48.0
23.6
16.0
1.0 Occupants X 230 Btuh/occ.
0.0 Dwelling Unit X 1 1,200 Btu
I Infiltration: 1.064 X 0.94 X 52.37 X 42 =
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
Occupants 1.0. Occupants X
Infiltration: 4,771 X 0.94 X 52.37 X 0.00523
Air Sensible CFM ELA AW
GLF
X 23.6 =
X 52.1 =
X 52.1 =
X 30.7 =
X 30.7 =
X 51.3 =
X 30.7 =
X 30.7 =
X 30.7 =
Page Total
I -TY OF LA UU1I 1
.�2'o r YLI c SAFE ED
AP ONS®RUCTiO
FOR C
• I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM i DATE -�
Btu/hr
1,916
569
1,308
1,737
142
113
5,7851
Btu/hr
473
240
240
614
908
1,848
491
1,473
491
6,777
Btu/hr
230
0
2,189
16,259
Bt /hr
200
1, 223
•
(9
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7912412014
ate
Engler Residence
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area 957.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area
U -Factor
CLTD'
Btu/hr
X
X
X
X =
X
X =
X
X =
X
X
X
X =
X
X
X
X =
X
X =
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area
GLF
Area GLF
Btu/hr
Window (NE)
0.0 X 23.6 +
36.0 X 35.5
_ 1,278
X +
X
-
X +
X
=
X +
X
=
X +
X
=
X +
X
-
X +
X
X +
X
X + I
X
Page Total
1,278
Internal Gain
Btu/hr
Occupants 1.0 Occupants X
230
Btuh/occ. =
230
Equipment 0.0 Dwelling Unit X
1,200
Btu =
0
Infiltration: 1.064 X 0.94 X 52.37 X 42 =
2,189
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
`� CdtV59
�` SA
Latent Gain
gUiLDING
a. ®\J
F . B u/hr
Occupants 1.0 Occupants X
00
13tuMacPP TR�1
TION 200
F
Infiltration: 4,771 X 0.94 X 52.37
X 0.00523 =
1,22 -
Air Sensible CFM ELA
6W
DATE ------� 13
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,423
EnemvPro 5.1 by EnerqvSoft User Number.' 6712 RunCode: 2014-09-24720:50:51 /D:
Page 37 of 37
Electron:)cally Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R
Project Name
Engler Residence
Building Type 1Z Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC 1 Master Suite
1,232 13,552
HVAC 2 North Bedroom
511 5,110
South Bedroom
475 4,750
HVAC 3,4 & 5 Living Zone
4,012 51,354
HVAC 6 Guest Suite
957 10,049
Totals 1 7,187 0 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Ett. Cooling Type Min. Ett. Thermostat Type
Status
HVAC 1 1 Central Furnace
80% AFUE Split Air Conditioner 14.5 SEER Setback
New
HVAC 2 1 Central Furnace
80% AFUE Split Air Conditioner 14.5 SEER Setback
New
HVAC 3,4 &,5 ;-' : , 3 Central Furnace--.
80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC 6 + 1 ; Centr`al Furnace ►
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION i rl (+
,+I 1 1
�' `'
System Name Heating
- 'Duct Ducts
Cooling Duct Location R -Value Tested?
Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0 m
New
HVAC 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0 m
New
HVAC 3,4 & 5 Ducted
Ducted Attic, Ceiling Ins, vented 8.0 E)
New
HVAC 6 Ducted
Ducted Attic, Ceiling Ins, vented 1 8.01 m
New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White 100 Gal
2
Large Gas
All Pipes Ins
90,000
100
0.80
0.00%
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
n
c
v c
-tne
TY d
s n1t� $cS
Tgy�.stem-Na
—
\ QU'
�LpeY
Len tb„_Diameter
NTA
DEPripe,
Insul.
Thick.
Qt . HP
Plenum Outside
Buried
❑
I :«6C)N1.0,'FRLJQ10N
❑
i DATE
J_
L- - - - - - - - - - - - - - - - —
EnergyPro 5.1 by EnergySoft User Number., 6712
Run Code: 201409-24T20:50:51 /D: Pae 10 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electron:;cally Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at Ca10ERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
9/24/2014
Project Address
57-615 Coral Mountain Court La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,187
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 7,187 Radiant Barrier New
Wall Wood Framed
R-21 6,072 New
Slab Unheated Slab -on -Grade
None 7,187 Perim = 736' New
FENESTRATION U- Exterior
Orientation Area(ft2) Factor SHGC Overhang Sidefins Shades Status
Front (NE) 361.9 0.390
0.32 none none Bug Screen
New
Left (S) 937.1 0.390
0.32 none none Bug Screen
New
Rear (lAq 282.6 0.390
0.32 none none Bug Screen
New
Right (N11 60.6 0.390
0.32 none none Bug Screen
New
Right (N) 205.3 0.390
0.32 none none Bug Screen
New
Front (E) 80.7 0.390
0.32 none none Bug Screen
New
Left (SE) 45.0 0.390
0.32 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 14.5 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 14.5 SEER Setback
New
3 Central Furnace 80% AFUE
Split Air Conditioner 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 Ducted
Ducted Attic, Ceili 0
e
HVAC 2 Ducted
Ducted Attic, Ceili 0
New'
HVAC 3,4 & 5 Ducted
Ducted Attic, Ceiling InsVg-0d�.,0 c -t �( pElU�w
,�
WATER HEATING
Ot . Type Gallons Min. Eft Distr' F n^ r'"�' � '�1§tatA
2 Large Gas 100
0.80 AA)MOIlY �j/ Qp�i v
New
li�—
EnergyPro 5.1 by EnergySoft User Number. 6712
Run Code: 201409-24720:50:51 ID:
Pae 1 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electron-,cally Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at Ca10ERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
9/24/2014
Project Address
57-615 Coral Mountain Court La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,187
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity f Features see Part 2 of 5 Status
FENESTRATION kU- Exterior
Orientation Area(fi`) Factor SHGC Overhang Sidefins Shades Status
,�J,`''7
✓/ :,f � i i i � I Y''�''�� ,. f
# ��,, �,{'- `'� �'l . �! , :.� , "` _ �S'_ ��`,�1 �`C��6y�,�:r I�`' \:J
y,,�y..
��
f
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC 6 Ducted Ducted Attic, Ceiling Ins, venteI qw
tT OIL LJA "J" r
Qt t MING & SHi-t iI Ll"'
WATER HEATING APPF'-�(\/t--^I
Qty. Type Gallons Min. Eff Distrib tion 'nll r, NSTRVC N91atus
BY
�-
EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2014-09-24T20:50:51 ID: Page 2 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Building Type 0 Single Family ❑ Addition Alone
Date
Engler Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
9/24/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Bradford -White 100 Gal is a non-NAECA large storage gas water heater. Verify DHW details.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 1, 008.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite
HIGH MASS Design - Verify Thermal Mass: 224.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite
The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 409.0 ft2 Covered Slab Floor, 3.500" thick at North Bedroom
HIGH MASS Design - Verify Thermal Mass: 102.0 ft2 Exposed Slab Floor, 3.500" thick at North Bedroom
HIGH MASS Design - Verify Thermal Mass: 355.0 ft2 Covered Slab Floor, 3.500" thick at South Bedroom
HIGH MASS Design - Verify Thermal Mass: 120.0 ft2 Exposed Slab Floor, 3.500" thick at South Bedroom
The HVAC System HVAC 3, 4 & 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must
have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 664.0 ft2 Covered Slab Floor, 3.500" thick at Living Zone
HIGH MASS. Design -Verily Thermal Mass: 3,348.0 ft2 Exposed Slab Floor, 3:500" thick at Living Zone
The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
-
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HERS REQUIRED VERIFICATION f
Items in this section require field testing and/or verification by a certified HERS Rater. The'inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Carrier 24ANB646158C VX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB648158CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANB660158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 3, 4 & 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
ni it 'TA
The HVAC System HVAC 3, 4 & 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testin_g"i quiz d�to verify that
duct leakage meets the specified criteria. , v , • ; .etc. & ,AFE I �
The Cooling System Carrier 24ANB636158CVX070 includes credit for a 13.0 EER Condenser. `A'cerfified HERS rater Mds? field erify the i stallation
of the correct Condenser. �` '� I X- 1�
The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display o ijz' t rku
v
1 r lam+
i
The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing quired to veri tha duct
Bis�
leakage meets the specified criteria. rc �
EnergyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2014-09-24T20:50:51 ID: Page 3 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
9/24/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 471.0 ft2 Covered Slab Floor, 3.500" thick at Guest Suite
HIGH MASS Design - Verify Thermal Mass: 486.0 ftZ Exposed Slab Floor, 3.500" thick at Guest Suite
The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
T77 7
j
HE REQUIRED, VERIF{CATION �yj j f,�
uY�/ i Y S �.'t �. �. �F`-..moi:%/ - _• ''.. .. it V .- -� i�.%7 R �Gs �.1.:;
Items in,tflis S2CtI0n requirefield testing'and/or verification°by a-certified'HER8 Rater! The inspectortmust receive a
completed CF -4R form for each of the measures listed below for final to be given.
i i C \A -T A
CET Ur
r-NIKt , &SAFETY DEPT.
FOR CONS
BY
EnerqvPro 5. i by Ene Soft User Number: 6712 RunCode: 2014-09-24T20:50:51 /D: Page 4 of 10
Reg: 214-N0301031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type lZ Single Family ❑ Addition Alone
Date
Engler Residence
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
9/24/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 4.70 2.84 1.86
Space Cooling 53.68 45.55 8.13
Fans 10.68 13.52 -2.83
Domestic Hot Water 5.08 3.42 1.66
Pumps 0.00 0.00 0.00
Totals 74.14 65.33 8.81
Percent Better Than Standard: 11.9%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NE) 1,846 443
Fuel Available at Site: Natural Gas (SE) 3,013 982
Raised Floor Area: 0 (StM 1,375 283
Slab on Grade Area: 7,187 (NW) 1,811 266
Average Ceiling Height: 11.8 Roof 7,187 0
Fenestration Average U -Factor: 0.39 TOTAL: 1,973
Average SHGC: 0.32 Fenestration/CFA Ratio: 27.5%
REMARKS
r ,
rl f
If
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
9/142014
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building d-esign-r-epresentediniliis set
documents is the forms the and
of construction consistent with other compliance and�.sd—h ets, with specificati0ns,,
with any other calculations submitted with this permit application, and recognizes that compliance�usDng,d,ug4- �desig ,
duct sealing, verification of refrigerant charge, insulation installation qualityi, anted 0(L0i'r genvelope sealing require
installer testing and certification and field verification by an approved HERS rater.
pipt�� �` ED
J�.t
Designer or Owner (per Business & Professions Code) FOR CONSTRUCTION
Company Walling & McCallum Limited
Address 45190 Club Drive Name Kevin Leonhard DATE -�_ BY
City/State/Zip Indian Wells, CA 92210 Phone (760) 360-0250 Signed License # Date
EnerqvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2014-09-24720:50:51 /D: Page 5 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: Ca10ERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Roof
1,232
0.026 R-38
270 0 New 4.2.1-A9
Zone 1 Master Suite
Wall
189
0.069 R-21
0 90 New 4.3.1-A6
Zone 1 Master Suite
Wall
61
0.069 R-21
45 90 New 4.3.1-A6
Zone 1 Master Suite
Wall
147
0.069 R-21
90 90 New 4.3.1-A6
Zone 1 Master Suite
Wall
238
0.069 R-21
180 90 New 4.3.1-A6
Zone 1 Master Suite
Wall
235
0.069 R-21
225 90 New 4.3.1-A6
Zone 1 Master Suite
Wall
17
0.069 R-21
270 90 New 4.3.1-A6
Zone 1 Master Suite
Wall
226
0.069 R-21
315 90 New 4.3.1-A6
Zone 1 Master Suite
Slab
1,008
0.730 None
0 180 New 4.4.7-A1
Zone 1 Master Suite
Slab
224
0.730 None
0 180 New 4.4.7-A1
Zone 1 Master Suite
Roof
511
0.026 R-38
270 0 New 4.2.1-A9
Zone 2 Bedroom North
Wall
115
0.069 R-21
0 90 New 4.3.1-A6
Zone 2 Bedroom North
Wall
206
0.069 R-21
45 90 New 4.3.1-A6
Zone 2 Bedroom North
Wall
30
0.069 R-21
225 90 New 4.3.1-A6
one 2 Bedroom North
Wall
205
0.069 R-21
315 90 New 14.3.1-A6
JZone 2 Bedroom North
Slab
409
0.730 None
0 180 New 4.4.7-A 1
Zone 2 Bedroom North
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC Azm Status Glazing Type
Location/Comments
1
Window
38.5 0.390 NFRC
0.32 NFRC 45 New Double Non -Metal Tinted
Zone 1 Master Suite
2
Window
27.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 1 Master Suite
3
Window
- 54.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 1 Master Suite
4
Window
27.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 1 Master Suite
5
Window_ „ -_
27.0 0.390 NFRC
0.32 NFRC 270 NewDouble Non -Metal Tinted �.
Zone 1 Master Suite
6
Window.
20.0 0.390 NFRC ,s f 0.32 NFRC,, ' -315 Newg � '� Double Non -Metal Tinted'. _
fir' Zone 1 Master Suite
7
Window
30.0 0.390 NFRC i •.'0.32 NFRC' r 315 New, r' ; Double Non -Metal Tinted;:, ,
* Zone 1 Master Suite
8
Window
5.3 :,0.390, NFRC Pi
0.32 NFRC C, 0 New;.. ,,► Double Non -Metal Tinted %,, Zone 2 Bedroom North
9
Window
10.14 j0.390 NFRC ;4
0.32 NFRC,45 New ` L + Double Non -Metal Tinted3
►;. Zone 2. Bedroom Northti
10
Window qil J16.0, 1;0.390 NFRC. ;
0.32 NFRC ' d45 New", „' Double'Non-Metal Tinted V
Zone 2 Bedroom North
11
Wlndow;rrt f, -I_:8.'0 ..,0.390 NFRC,,\. 1 "0.'32 NFRC 2n CL7.451 New _ 4 Double Non -Metal Tinted►' "+ Zone.'2'Bedroom North
12
Window
5.3 '0.390 NFRC -
- 0.32 NFRC 315 New Double Non -Metal Tinted
Zone 2 Bedroom North
13
Window
_ 36.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 2 Bedroom South
14
. Window
'48.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 2 Bedroom South
15
Window
24.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 2 Bedroom South
16
Window
36.0 0.390 NFRC
0.32 NFRC 180 New Double Non -Metal Tinted
Zone 2 Bedroom South
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window Ove hang Left Fin
H t Wd Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
1
_
10
Bug Screen
0.76
, I nt S. -ED`
11
Bug Screen
0.76
12
Bug Screen
0.76
v, n t
13
Bug Screen
0.76
r, S
14
Bug Screen
0.76
"
15
JBug Screen
0.76
16
JBug Screen
0.76
B -�
EnergyPro
5.1 by EnergySoft User Number: 6712 Run Code: 201409-24720:50:51 ID:
Page 6 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at Ca10ERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
102
0.730 None
0 180 New 4.4.7-A1
Zone 2 Bedroom North
Roof
475
0.026 R-38
270 0 New 4.2.1-A9
Zone 2 Bedroom South
Wall
205
0.069 R-21
180 90 New 4.3.1-A6
Zone 2 Bedroom South
Wall
130
0.069 R-21
270 90 New 4.3.1-A6
Zone 2 Bedroom South
Slab
355
0.730 None
0 180 New 4.4.7-A1
Zone 2 Bedroom South
Slab
120
0.730 None
0 180 New 4.4.7-A1
Zone 2 Bedroom South
Roof
4,012
0.026 R-38
270 0 New 4.2.1-A9
Loun e/Ta /Kit/G m/Offic
Wall
396
0.069 R-21
0 90 New 4.3.1-A6
Loun e/Ta /Kit/G m/Offic
Wall
319
0.069 R-21
45 90 New 4.3.1-A6
Loun e/Ta /Kit/G m/Offic
Wall
193
0.069 R-21
90 90 New 4.3.1-A6
Loun e/ra /Kit/G m/Offic
Wall
398
0.069 R-21
135 90 New 4.3.1-A6
Loungelra /Kit/Gym/Offic
Wall
480
0.069 R-21
180 90 New 4.3.1-A6
Loun e/1 a /Kit/G m/Offic
Wall
680
0.069 R-21
270 90 New 4.3.1-A6
Loun e/Ta /KibG m/Offlc
Wall
149
0.069 R-21
315 90 New 4.3.1-A6
Loun e/Ta /Kit/G m/Offic
Slab
664
0.730 None
0 180 New 4.4.7-A1
Loun e/ra IKibG m/Offic
Slab
3,348
0.730 None
0 180 New 4.4.7-A1
Lounge/Ta /Kit/G m/Offic
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor SHGC
Azm Status Glazing Type
Location/Comments
17
Window
5.3 0.390 NFRC 0.32 NFRC
180 New Double Non -Metal Tinted
Zone 2 Bedroom South
18
Window
16.0 0.390 NFRC 0.32 NFRC
180 New Double Non -Metal Tinted
Zone 2 Bedroom South
19
Window
40.5 0.390 NFRC 0.32 NFRC
0 New Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
20
Window
54.0 0.390 NFRC 0.32 NFRC
0 New Double Non -Metal Tinted
Lounge/Tap/KibGym/Office
21
Window--
40.5 0.390 NFRC „0.32 NFRC
_,0 NewDouble Non-Metal_Tinted-.",,,,-•
Lounge/Tap/KibGym/Office
22
Window:•
•145.0 0.390 NFRC ,A ;A, 0.32 NFRC,
--'.VO New' f: ---N Double Noh-Metal Tinted :
Ss Lounge/rap/Kit/Gym/Office
23
Kcindow,
'60.0 0.390 NFRC -1 , 0.32 'NFRC . ,.
- 45 New,- " : ,r Double Non -Metal _Tinted e.. _
• Lounge/Tap/Kit/Gym/Office
24
Window
9.p,' `,0.390, NFRC F. 0.32 NFRC 9-
:..f 45 New„;. oP Double Non -Metal Tinted. \,4_ Lounge/Tap/KitlGym/Office
25
Window
6,010 .10.390 NFRC,-1, 0.32 NFRC..:
1 45 New z Double Non -Metal Tinted'*
4 Lounge/Tap/KiVGym/Ofce
26
Window ,t J60.0; b,0.390, NFRC,'v 0.32 NFRC t
A#45 'New -A .. Double`Non-Metal Tinted A
" Lounge/TaplKit/Gym/Office
27
INindowA (,16.0 ;,,.0:390 NFRCL.,9 *rr0.32 NFRCat!
;Z'45 New. '%.. Double Non-Metal=Tinted`'
" Lounge/Tap/Kit/Gym/Office
28
Window
24.0 '0.390 NFRC "'0.32 NFRC-:
45 New Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
29
Window
_ 16.0 0.390 NFRC 0.32 NFRC
45 New Double Non -Metal Tinted
Lounge/ra /KibGym/Office
30
Window'
',.,8.0 0.390 NFRC 0.32 NFRC
45 New Double Non -Metal Tinted
Lounge/Tap/KibGym/Ofce
31
Window
71.5 0.390 NFRC 0.32 NFRC
90 New Double Non -Metal Tinted
Lounge/rap/KibGym/Office
32
Window
9.0 0.390 NFRC 0.32 NFRC
1351 New Double Non -Metal Tinted
Lounge/Tap/KibGym/Ofce
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window Ove hang Left Fin
Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
_
25
Bug Screen
0.76
_ -�-- �"'�- _ w A
n I I i
26
Bug Screen
0.76
r.n `{ 0 i Li-
-_ rnT
27
Bug Screen
0.76
,' Alf R,
1=t i
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
` . n r. r)Nsl K V 1 w
31
Bug Screen
0.76
32
JBug Screen
0.76
y
DATE ------- BY
EnergyPro,
5.1 by EnergySoft User Number: 6712 Run Code: 2014-09-24T20:50:51 /D:
Pae 7 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Desiqn and Title 24, Inc.) 9/25/2014
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Roof
957 0.026 R-38
270 0 New 4.2.1-A9 Guest Suite
Wall
266 0.069 R-21
0 90 New 4.3.1-A6 Guest Suite
Wall
431 0.069 R-21
90 90 New 4.3.1-A6 Guest Suite
Wall
225 0.069 R-21
180 90 New 4.3.1-A6 Guest Suite
Wall
48 0.069,R-21
135 90 New 4.3.1-A6 Guest Suite
Wall
437 0.069 R-21
180 90 New 4.3.1-A6 Guest Suite
Wall
48 0.069 R-21
45 90 New 4.3.1-A6 Guest Suite
Slab
471 0.730 None
0 180 New 4.4.7-A1 Guest Suite
Slab
486 0.730 None
0 180 New 4.4.7-A1 Guest Suite
FENESTRATION SURFACE DETAILS
ID
Type Area LI -Factor' SHGC
Azm Status Glazing Type Location/Comments
33
Window 16.0 0.390 NFRC 0.32 NFRC
180 New Double Non -Metal Tinted LoungelTap/KibGym/Office
34
Window 38.5 0.390 NFRC 0.32 NFRC
180 New Double Non -Metal Tinted Lounge/Tap/KibGym/Office
35
Window 42.0 0.390 NFRC 0.32 NFRC
180 New Double Non -Metal Tinted Lounge/Ta /KibGym/Office
36
Window 154.0 0.390 NFRC 0.32 NFRC
180 New Double Non -Metal Tinted Lounge/Tap/Kit/Gym/Office
37
Window ,-_ 38.5 0.390 NFRC NFRC
180 New- _.._, Double Non -Metal Tinted.-,,,.-, Lounge/Tap/KibGym/Office
38
_0.32,
'N28.9 0.390 NFRC . o � 0.32 ;NFRC; � '- - 180 New f --1 Double Non -Metal Tinted' _ 'It, Loungelrap/Kit/Gym/Office
39
$93.5 0.390 NFRC 1 0.32 'NFRC
180 Newi f ; Double Non -Metal Tinted_: " Lounge/Tap/Kit/Gym/Office
40
rWYnd6w;-
38.9_,-%6.390, NFRC 1, 0.32 NFRC Gt A 180 New;--fx Double Non -Metal Tinted .k,,, Lounge/Tap/Kit/Gym/Office
41
1,8;4 (0.390 NFRC,,,' 0.32 NFRC;-'_ .1 180 New 1. s Double Non -Metal Tinted It 'i:; Lounge/Tap/KiUGymLOfrice
42
d J48.0;x,0.390. NFRC J 0.32 NFRC c ,180 New,,.V ' Double -Non -Metal Tinted 3 LoungelTap/KibGym/Office
43
t 9-18.4 -0.390 NFRC-C�40:32 NFRC c:V180 New +w Double Non-Metal7iriteds`ti L6u64e/Tap/KibGym/Office
44
Window '8.0 "0.390 NFRC : " 0.32 NFRC
-270 New ` Double Non -Metal Tinted Lounge/Tap/Kit/Gym/Office
45
Window _ 48.0 0.390 NFRC 0.32 NFRC
270 New Double Non -Metal Tinted Lounge/Ta /KibGym/Office
46 . Window' 1-.8.0 0.390 NFRC 0.32 NFRC
270 New Double Non -Metal Tinted Lounge/Tap/KibGym/Office
47
Window 71.5 0.390 NFRC 0.32 NFRC
270 New Double Non -Metal Tinted Lounge/Tap/Kit/Gym/Office
48
Window 22.0 0.390 NFRC 0.32 NFRC
270 New Double Non -Metal TintedLounge/Tap/KibGym/Office
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt REA Dist Len Hcit Dist Len H t
33
Bug Screen 0.76
34
Bug Screen 0.76
35
Bug Screen 0.76
36
Bug Screen 0.76
37
Bug Screen 0.76
38
Bug Screen 0.76
39
Bug Screen 0.76
40
Bug Screen 0.76
r
41
Bug Screen 0.76
w A U t 9
42
Bug Screen 0.76
A r✓ CT V1 E
43
Buq Screen 0.76
111 OU"'o O`
44
Bug Screen 0.76
4. r-; n
45
Bug Screen 0.76
46
Bug Screen 0.76
Foie V W
47
-Bug Screen 0.76
48
JBug Screen 1 0.76
EnergyPro
5.1 by EnergySoft User Number. 6712 RunCode: 2014-09-24720:50:51 ID: Page 8 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc
Electronbcally Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2014
Electronically Signed at CalCERTS.com by Tim Scott (Scott Design and Title 24, Inc.) 9/25/2014
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Engler Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1912412014
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
LI -Factor SHGC Azm Status Glazing Type
Location/Comments
49
Window 18.7
0.390 NFRC 0.32 NFRC 270 New Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Ofrce
50
Window 60.5
0.390 NFRC 0.32 NFRC 270 New Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Ofrce
51
Window 13.6
0.390 NFRC 0.32 NFRC 270 New Double Non -Metal Tinted
Lounge/Ta /KAIGym/Office
52
Window 5.3
0.390 NFRC 0.32 NFRC 270 New Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
53
Window__ -� 5.3
0.390 NFRC .0.32 NFRC 315 New . Double Non -Metal Tinted
Lounge/Tap/Kit/Gym/Office
54
Window: '\20.0
0.390 NFRC .J `r�.0.32 NFRC'. - -3%0 New f Double Non -Metal Tinted,
; Guest Suite
55
Window. ` 4.6
0.390 NFRC. f 0.32 'NFRC . 90 New;; = ' ; Double Non -Metal Tinted L,.
Guest Suite
56
Window 4.6, X0.390 NFRC ; : ' 0.32 NFRC x:'. �4 90 New -,:.r-' Double Non -Metal Tinted' 4'
Guest Suite
57
Window 20:0
10.390 NFRC 1 0.32 NFRC • 180 New, *. Double Non -Metal Tinted -N
Guest Suite,, ...
58
Window J29.6„r, 0.390 NFRC "_t 0.32 NFRC; X180 'New Tt Double Non -Metal Tinted l
".; Guest Suite;. 11
59
WindowA0"1,36.0 :,:.0.390.NFRC_,.* "0.32 NFRC X135 New X. Double Non-Metal-Tintedat,0 GuestSuite'%'Ve
60
Window 16.0
0.390 NFRC 0.32 NFRC 180 New Double Non -Metal Tinted
Guest Suite
61
Window 48.0
0.390 NFRC 0.32 NFRC 180 New Double Non -Metal Tinted
Guest Suite
62
Window '16.0
0.390 NFRC 0.32 NFRC 180 New Double Non -Metal Tinted
Guest Suite
63
lWindow 1 36.0
0.390 NFRC 0.32 NFRC 45 New Double Non -Metal Tinted
Guest Suite
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
Window Ove hang Left Fin
SHGC H t Wd Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
55
Bug Screen
0.76
56
Bug Screen
0.76
1
57
Bug Screen
0.76
L
58
Bug Screen
0.76 i
CC
59
Bug Screen
0.76 a lit
60
Bug Screen
0.76 i t7 -0,
V M
61
Bug Screen
0.76 { �.1
10
62
Bu Screen
0.76 M =0R t
63
Bug Screen
0.76 {
DATE �
En-ergyPro
5.1 by EnergySoft User Number: 6712 RunCode: 2014-09-24720:50:51 ID:
Page 9 of 10
Reg: 214-N0101031A-000000000-0000 Registration Date/Time: 2014/09/25 00:12:50 HERS Provider: CalCERTS, Inc