9907-596 (OFC) Title 24Lai- mf C H A NAI C A I Designs, Inc. Consulting Engineers i - w ENERGY COMPLIANCE REPORT FOR GREG NORMAN GOLF CLUBHOUSE LA QUINTA.- CALIFORNIA PREPARED FOR DFD ARCHITECTURE JULY 1.999 19557 MARTIN B. SCHREIBER, . 7227 North 16th Street Suite 215 Phoenix, AZ 85020 602.943.6608 FAX 602.943.6181 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION OATS . 8Y� aen� 60,71, Title 24 Energy Compliance Documentation Prepared for: Mechanical Designs, Inc. Project Title:GREG NORMAN GOLF CLUBHOUSE La Quinta, CA 0 10308 Placer Lane, Sacramento, CA 95827 • (916) 364-1786 • FAX (916) 364-1789 � 1 � Envelope Mandatory Measures E1 Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material. E2. All insulating materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections §2602 and §707 of the Title 24, Part 2. E3 All exterior joints and openings in the building envelope that are observable sources of air leakage shall be caulked, gasketed, weather-stripped or otherwise sealed. E4 Site constructed doors, windows and skylights shall be caulked between the unit and the building, and shall be weather-stripped (except for unframed glass doors and fire doors). E5 Manufactured doors and windows shall have air infiltration rates certified by the manufacturer per §116 of the Energy Efficiency Standards. E6 Manufactured fenestration products must be labeled for U -value according to NFRC procedures. E7 The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. Mechanical Mandatory Measures EQUIPMENT CERTIFICATION M1 Any appliance that is subject to the Appliance Efficiency Standards must be certified by the Energy Commission. M3 Air handling duct systems shall be constructed, installed, sealed, and insulated as provided in Chapter 10 of the Uniform Mechanical Code. CONTROLS M4 Each space conditioning system shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends, and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted. M7 Each space conditioning system shall be installed with controls that restart and temporarily operate the system as required to maintain a setback heating and/or setback cooling thermostat setpoint. M10 Each space conditioning zone shall be controlled by an individual thermostatic control that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55°F or lower. For cooling, the control shall be adjustable up to 85°F or higher. Where used to control both heating and cooling, the control shall be capable of providing a dead band of at least 5°F within which the supply of heating and cooling is shut off or reduced to a minimum. VENTILATION M13 Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates specified. M14 Outdoor air supply and exhaust equipment shall be installed with gravity or automatic dampers. M17 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor. I. � T ` WATER HEATING SYSTEMS M19 The following service water heating systems and equipment may be installed only if the manufacturer has certified that the equipment meets or exceeds all applicable efficiency requirements listed in §113 of the Energy Efficiency Standards: Oil -fired storage types > 105,000 Btu/hr; Oil -fired non -storage types > 210,000 Btu/hr; Gas-fired non - storage types > 200,000 Btu/hr. M20 Unfired service water heater storage tanks and backup tanks for solar water heating systems shall have either: external insulation with an installed R -value of at least R-12; internal and external insulation with a combined R -value of at least R-16; or sufficient insulation so that the heat loss of the tank surface based on an 80°F water -air temperature difference shall be less than 6.5 Btu/hr-sf. M21 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. M22 Lavatories in public restrooms shall be equipped with flow rate controls as specified in §113(b)3. of the Energy Efficiency Standards. M23 Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110°F. Lighting Mandatory Measures Ll Each room is equipped with a separate manual switch or occupancy sensor device. All manual switches are located so that personnel can see the controlled area when operating the switches. L2 All rooms greater than 100 square feet and with more than 1.2 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. L3 All rooms that are greater than 250 square feet and have windows and skylights that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch. L4 All fluorescent fixtures shall be certified by the manufacturer and listed in the Directory of Certified Luminaries and Ballasts. L5 All one and three lamp fluorescent fixtures are tandem wired with two (2) lamp ballasts where required by §132 of the Energy Efficiency Standards. L6 All automatic control devices specified are certified and installed as directed by the manufacturer. L7 Display lighting is separately switched on circuits that are 20 amps or less. L8 The building lighting shut-off control system consists of an automatic time switch with a manual accessible override switch in sight of the lights, for each floor or each 5,000 square foot zone. L9 Exterior mounted fixtures served from inside the building are controlled with a directional photocell control. TITLE 24 REPORT Title 24 Report for: Greg Norman Golf Course, Clubhouse La Quinta, CA Project Designer: DFD Architecture Phoenix, AZ (602) 957-4758 Report Prepared By: Gregory Mize Valley Energy Consultants 10308 Placer Lane, Suite #200 Sacramento, CA 95827-2511 (916) 364-1786 Job Number: 90713 Date: 7/16/99 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.0 By EnergySoft Job Number. 90713 User Number. 25311 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 Greg Norman Golf Course, Clubhouse DATE 7/16/99 PROJECT ADDRESS La Quinta -: BuildinglPermit:# DFD Architecture (602) 957-4758 ` DOCUMENTATION AUTHOR Valley Energy Consultants TELEPHONE (916) 364-1786 Checked by/Date.. - EnOcementAgency.use STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies o ly to a Building using the performance compliance approach. M6/qq__ Gregory MizeD The Principal Designers hereby certify that the proposed ku-ildIft dipresented in he construction documents nd modelled for this permit application are consistent with all o r for rajnworksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the 5,218 Sq.Ft. ENV. LTG. MECH. 15 BUILDING TYPE �( NONRESIDENTIAL Ei ❑ 2. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION 0 ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies o ly to a Building using the performance compliance approach. M6/qq__ Gregory MizeD The Principal Designers hereby certify that the proposed ku-ildIft dipresented in he construction documents nd modelled for this permit application are consistent with all o r for rajnworksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. Ei ❑ 2. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. ❑ [:] R 3. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms DFD Architecture L.KiHTIN(i COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1, LTG -3 Required Forms PRINCIPAL LIGHTING DESIGNER . NAME SW Engineering Indicate location on plans of Note Block for Mandatory Measures MECH-1, MECH-2, MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME MEC14XW1C4L. OESIdOS SIGNATURf_ 1�ilS51 I *)-Ia'a9 User Number. 2531 :51:2V Kun PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 PROJECT NAME E Greg Norman Golf Course, Clubhouse 7/16/99 ANNUAL SOURCE ENERGY USE SUMMARY u sq -yr ENERGY COMPONENT Standard Design Proposed Compliance Design Margin 3.79 1.90" 99.00 12.99 47.72 1.61 0.00 0.00 0.00 0.0081 27.31 0.25 63.70 -16.62 13.05 0.00 28.17 282.75 0.13 Space Heating Space Cooling Indoor Fans Heat Rejection _ Pumps Domestic Hot Water Lighting Receptacle Process TOTALS: 5.69 80"'`'""0 I� } 0 10 20 N 40 50 60 70 80 00 100 110 ketWsgR-yr. 112.00 49.33 0.00 0.00 27.56 47.09 13.05 28.17 282.89 Building Orientation (East) 90 deg Conditioned Floor Area 5,218 sqft. Number of Stories 1 Unconditioned Floor Area 0 sqft. Number of Systems 8 Conditioned Footprint Area 5,218 sqft. Number of Zones 7 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (Easo 984 sqft. 66 sqft. 6.7% Left Elevation (south,) 510 sqft. 165 sqft. 32.4% Rear Elevation (West) 1,336 sgft. 516 sqft. 38.6% Right Elevation (North 1,964 sqft. 257 sqft.. 13.1% Total 4,794 sqn 1,004 sgft. Roof 5,218 sqft. sqft. 0.0% Standard Proposed Lighting Power Density 1.599 W/sqft. 2.302 W/sqft. Prescriptive Env. Heat Loss 1,325 731 Prescriptive Env. Heat Gain 72,869 40,210 emar s: Run InitiationTime: un Code: 932147849 EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number. 90713 Page:3 of 19 [PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 DATE Greg Norman Golf Course, Clubhouse 7/16/99 Y. C^ The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and a documentation for their use have been provided by the applicant. r Authorized Signature or Stamp Run Initiation Time: 07/1619910:57:29 Run Code: 932147849 EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number: 90713 PageA of 19 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1I E 7"regNorman Golf Course, Clubhouse DATE 7/16/99 10 AQUE SURFACES # Surface Type Framing Type Solar Act. Gains Area U -Val. Azm. Tilt Y/N Form 3 Reference Location / Comments 1 Wall Wood 192 0.065 240 90 R-19 Wall (W.19.2x6.16) Dining & Bar 2 all Wood 216 0.065 0 90 X R-19 Wall (W.19.2x6.16) Dining & Bar 00 o0 3 .03 0 oo .3 x Dining Bar -4 o0 oo X Metal Roofw Rigidnsu a ion Dining Bar a WoodX a x Kitchen a oo a x.16) Kitchen Door MetalX Hollow Metal Door Kitchen 00 00 oo . x 2.16) Kitchen a oo X a (W.19.2x6.16) es rooms aWood a 92x6. . es rooms Nor M e I a X Hollow Metal oores rooms Wall oo a x . es rooms a oo 7-R-19 a (W.19.2x6.16) es rooms 14 Door e a o ow e a oor Kestrooms 00Wood X R-30 Root(R.30.2xTZ.-fgy-TTe-sTrooms- f a oo a x es rooms a oo - a x . es rooms 18 Door Metal 20 0 90 X Hollow metal Door Restroorns T9-9o-oT-VTo-o-d--X R-30 Roof(R.30.7x_fVBT_es rooms a oo a Storage 113 & Uressing # Type Act. Area U -Val. Azm. SHGC Glazing Type Location / Comments 1 -2-Window Window 96 0.280 240 0.57 Double Low E Tinted ining & Bar 9 0.280-T4-6-0.57 Double Low E TintedDining & Bar 3 Window 66 0.57 Double Low E TintedDining & Bar 4 lWindow 96 0.280 0 0.57 Double Low E Tinted ining & Bar 5 -6--Window Window 32 0.280 0 0.57 Double Low E Tinted ining & Bar 16 .280 20 0.57 Double ow mte forage Dressing m ow 5 .280 20 .57 Double ow ante ices 8 Window 99 0.280 210 0.57 Double Low E Tinted ffices 9 Window 66 0.280 210 0.57 Double Low E Tinted ro Shop Window 6 300 .57 Double Low E Tintedro Shop 11 Window 96 0.28 00 0.57 Double Low E Tintedro op 12 Window 96 0.280 300 0.57 Double Low E Tinted ro Shop 13 -4 -Window Window 96 0.280 0 0.57 Double Low E Tinted ro Shop f 3 .28 .57 Double Low E Tintedro Shop EXTERIOR SHAUINU # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Len. Hgt. Left x . xt. Dist. Len. Fin Right Fin HgE Dist. Len. 9• 1 None 0.75 8.0 12.0 5.0 2.0 5.0 5.0 2 None 0.76 8.0 12.0 11.0 4.5 11.0 11.0 3 None 0.76 5.5 12.0 5.0 2.0 5.0 5.0 4 1 None 0.76 8.0 12.0 20.0 0.1 20.0 20.0 5 None 0.76 5.0 6.5 20.0 0.1 20.0 20.0 6 one 0.76 5.5 3.0 5.0 2.0 5.0 5.0 7 one .5 9. 5. 8 None 0__T6_ 5.5 18.0 20. 9 one 0.76 5.5 12.0 .0 2.0 10 None 0.76 5.5 12.0 5.0 2.0 5.0 5.0 11 1 None 0.76 8.0 12.0 5.0 2.0 5.0 5.0 12 1 None 0.76 8.0 12.0 11.0 4.5 11.0 11.0 13 one 0.7 0. 14 None .7 .5 0.20.0 20.0 Run Initiation Time: 07/16/99 10:57:29 Run Code: 932147849 EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number. 90713 Page:5 of 19 I r�. ENVELOPE COMPLIANCE SUMMARY Performance ENVA PROJECT NAME Greg Norman Golf Course, Clubhouse DATE 7/16/99 # Surface Type Framing Type Solar Act. Gains Area U -Val. Azm. Tilt YIN Form 3 Reference Location / Comments 21 Roof Wood 264 0.035 - 0 0 XII I R-30 Roof(R.30.2x12.16) Storage 113 & Dressing 22 Wall Wood 56 0.065 120 90 X III R-19 Wall (W.19.2x6.16) Offices 23 Wall Wood201 0.0650 90 XII R-19Wall.19.24.16 ices 24 00 o0 35 X oo x ices a oogo X - a x ro Shop a oo - a x ro Shop a oo X - a x ro Shop Root Wood00 xPro Shop 29 00 00 X Metal RootwRigid Ins-55—tion ro op a oo a x6.16) B—ag—WParts storage a oo X a xBag & Parts Storage a oo X —U.-Mff— - a x ag a s orage STRoor Metal --(F-- 90 X I I ollow Metal DoorBag & Parts Storage 34 00 00 X I K-JUoo x12.16) B—ag—YpPs storage # Type Act. Area U -Val. Azm. SHGC Glazing Type Location / Comments # Exterior Shade Type in ow Overhang SHGC Hgt. Wd. Len. Hgt. Left Fin Right Fin LExt.RExt. Dist. en. g . Dist. Len. Hgt. Run Initiation Time: 07/16/99 10:57:29 Run Code: 932147849 EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number: 90713 Page:6 of 19 _IGHTING COMPLIANCE SUMMARY Performance LTG -1 CONTROL LOCATION CONTROL (Room # or Dwg. #) IDENTIFICATION Dining & Bar Dining & Bar Dining & Bar Dining & Bar CONTROL TYPE (Occupant, Daylight, Dimmeng, etc.) Manual Dimming Manual Dimming Manual Dimming Manual Dimming LUMINAIRES CONTROLLED NOTE TO. FIELD`, F 5 1 5 1 10 E 17 Greg Norman Golf Course, Clubhouse 7/16/99 LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTIONPer DESCRIPTION # Watts Lamp DESCRIPTION # (Lamp + # ll Baast Watts Total Watts A 75w Wall Mount Incandescent 74W 1 75 No Ballast 4 75.0 300 B (1) 13w Compact Fluorescent 13TT 1 131 Magnetic Standard1• 8 17.0 136 E 100w Wall Mount Incandescent 100W 1 100 No Ballast 171 100.0 1,700 F 60w Wall Mount Incandescent 60W 1 60 No Ballast 5 60.0 300 50w Low Voltage Halogen Q50MR16 12 1 50 Magnetic Energy Efficient 1.0 34 55.01 1,870 J 50w Low Voltage Halogen Q50MR16(12V) 11 50 Magnetic Energy Efficient 1.0 34 55.0 1,870 K (4) 4 ft Fluorescent T8 ElecIS F32T8 4 32 Electronic Instant Start 2.0 25 126.0 3,150 L 75w Wall Mount Incandescent 74W 1 75 No Ballast 1 75.0 75 M 50w Low Voltage Halogen Q50MR16 12 1 50 Magnetic Energy Efficient 1.q 38 55.0 2,090 N (2) 8 ft Fluorescent T12 Slimline F96T12 2 751 Magnetic Standard 1. 3 173.0 519 Page Total 12,010 Building Total 12,010 Less Control Credit Wa (From LTG -3) 727 Adjusted Actual WattsL 11,283 CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROLTYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE. TO FIELD ' CONTROL LOCATION CONTROL (Room # or Dwg. #) IDENTIFICATION Dining & Bar Dining & Bar Dining & Bar Dining & Bar CONTROL TYPE (Occupant, Daylight, Dimmeng, etc.) Manual Dimming Manual Dimming Manual Dimming Manual Dimming LUMINAIRES CONTROLLED NOTE TO. FIELD`, F 5 1 5 1 10 E 17 LIGHTING COMPLIANCE SUMMARY Performance LTG -1 PROJECT NAME t Greg Norman Golf Course, Clubhouse 7/16/99 FG7HTIN,G COMPLIANCE SUMMARY Performance LTG -1 I PROJECT NAME Greg Norman Golf Course, Clubhouse g q- 7/16/99 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME Greg Norman Golf Course, Clubhouse rr- .k. SYSTEM NAME.. TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN.CONTROL VAV MINIMUM POSITION CONTROL? . SIMULTANEOUSHEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN AIR CFM (MECH-3, COLUMN 1) HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE ' COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE DUCT TAPE ALLOWED? PIPE TYPE (SUPPLY, RETURN, ETC.) . PIPE INSULATION REQUIRED? MECHANICAL SYSTEMS DHW Heater HP -1 thru 4 & HP -7 HP -5,6&8 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Gas Fired 78% n/a n/a Standard as 50 gal or Lest n/a n/a n/a n/a n/a Supply & Return HW Yes - HEAT PUMP THERMOSTAT? Heating & Cooling Required ELECTRIC HEAT? Yes 1 VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? Y: Yes N: No HEAT AND COOL SUPPLY RESET? Constant Temp HIGH EFFICIENCY? DUCT TAPE ALLOWED? PIPE INSULATION REQUIRED? No Economizer 1978 cfm Programmable Switch Heating & Cooling Required n/a Yes 1 0.0 kW Constant Volume No No Constant Temp Constant Temp Air Balance Auto No Economizer 1978 cfm Heat Pump 7.5 HSPF Split Heat Pump 10.2 SEER CARRIER 3tsYL;L;0605 Ducts in Attic 4.2 Ducts in Attic 4.2 No No Yes ns 7/16/99 Programmable Switch Heating & Cooling Require n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp Air Balance Auto No Economizer 668 cfm Heat Pump 7.2 HSPF Split Heat Pump 10.0 SEER Ducts in Attic 4.2 Ducts in Attic 4.2 No Yes t3: Air tsalance A: Auto C: Outside Air Cert G: Gravity M: Out. Air Measure D: Demand Control N: Natural ECONOMIZER O.A. CFM A: Air Enter Outdoor Air W: Water CFM. N: Not Required Note: This shall be n less than Col. H on - MECH-3. Page: 10 of 19 d t LIGHTING CONTROL CREDIT WORKSHEET LTG -3 PROJECT NAME Greg Norman Golf Course, Clubhouse DATE 7/16/99 A © LIGHTING CONTROL DESCRIPTION © o a o a o a PLANS REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR CONTROL CREDIT WATTS (G X H) ROOM # ZONE ID ROOM RATIO* GLAZING VLT eningar Manualimmmg F 1,355 300 0.10 30 eningar ManualDimming 1 1,355 275 0.10 28 Dining & bar Manual Dimming 1 1,355 550 0.10 55 Dining & BarManual immmgE ManualDimming 1 1,355 1,700 0.10 170 ining Bar 1,355 1,045 0.10 104 Dining Bar Manual Dimming M 1,355 660 0.10 66 Storage DressingManual Dimming K 264 378 0.10 38 Pro op anua immmg J 1,223 275 0.10 28 Pro op Manual Dimming J 1,223 550 0.10 55 Pro op Manual Dimming J 1,223 1,045 0:10 104 Pro Shop Manual Dimming M 1,223 495 0.10 50 Enter on LTG -2: PAGE BUILDING Actual Lighting TOTAL TOTAL Power calculation. 727 • For windows, use For skylights, use the Window Wall Ratio the Skylight -to -Roof ratio for the room. for the room. 727 Run Initiation Time: OV16/99 :57:29 Run Code: 93 47849 EnergyPro 2.0 By EnergySoft User Number 2531 Job Number. 90713 Page: 11 of 19 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME Greg Norman Golf Course, Clubhouse DATE 7/16/99 jGHILLhK AND TUWtK SUMMARY BHP Efficiency Tons PUMPS BHP Motor Eff. Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control C Constant Volume Draw -Through 1,200 0.25 77.0% 97.0% none BOILER SUMMARY Energy Factor Recovery Efficiency Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input (Gals.) Vol.or Ext. R -Val. Standard Gas 50 gal or Less. Small Gas Standard 1 40,000 50 0.53 n/a 12 JGENTKAL SYSTEM RATINGS System Name System Type Qty. Output Aux. kW Eff. Output Sensible Efficiency Economizer Type CARRIER 38YCC0605 Split Heat Pump 5 58,000 0.0 7.5 HSPF 56,000 39,20010.2 SEER No Economizer CARRIER 38 365 Split Heat Pump 3 36,000 0.0 7.2 HSPF 34,200 23,940 10.0 SEER No Economizer SUPPLY FAN I I RETURN FAN II System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Constant Volume Draw -Through 2,000 1.00 82.5% 97.0% none C Constant Volume Draw -Through 1,200 0.25 77.0% 97.0% none Run Initiation Time: 07/16/99 10:57:29 Run Code: 932147849 EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number. 90713 Page:12 of 19 MECHANICAL EQUIPMENT SUMMARY Part 2 • -. DATE 7/16/99 Reheat Coll L=UA1 . l . I . Code:Run-initiation Time: 07/16/99 10:57-29 Run (MECHANICAL VENTILATION MECH-3I -_ 71ECT NAME DATE . Greg Norman Golf Course, Clubhouse 7/16/99 i FA -1 a© o M 0© o a o 0 ZONE/SYSTEM Dining & Bar Kitchen Restrooms Storage 113 & Dressing Offices HP -1 thru 4 & HP -7 Pro Shop Bag & Parts Storage HP -5,6 & 8 AREA BASIS NO. OF PEOPLE GOND *MIN. AREA (SF) CFM PER SF CFM (B x C) 1,355 0.50 678 868 0.15 130 780 0.15 117 264 0.15 40 353 0.15 53 53 Total 40.q 1,223 0.25 306 375 0.15 56 612 Total 56 56 668 668 r OCCUPANCY BASIS NO. OF PEOPLE UFM PER PERSON MIN. CFM (EXF) 90.3 15.0 1,355 8. 15.0 130 7.8 15.0 117 2.6 15.0 40 3.5 15.0 53 53 Total 40.q 15.0 612 3.8 15.0 56 612 612 Total 56 56 668 668 r LOR DESIGN OUTDOO AIR CFM VAVTRANS. MIN. RATIO FER AIR 1,355 130 130 117 400 40 40 53 53 1,695 1,978 612 612 56 56 668 668 r L- -C7 Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1994 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air CFM includes ventilation from Supply Air System & Room Exhaust K Must be greater than or equal to (H minus 1). L EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number. 90713 Page: 14 of 19 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 Greg Norman Golf Course, Clubhouse 7/16/99 SUBTOTAL R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Sheet Metal 2 Membrane, Vapor -Permeable Felt 3 Plywood ASSEMBLY NAME IMetal Roof wl R19 Rigid Insulation 5 Fiber Board, Tile and Lay -in Panels ASSEMBLY Floor 7 0.29 s TYPE (check one) Wall 0.10 LILT INSIDE SURFACE AIR FILM 0.610 Ceiling I Roof 20.21 lL FRAMING MATERIAL Wood 5.2 z FRAMING %10% Framing 16% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTAL R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Sheet Metal 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Polystyrene, Smooth Skin 5 Fiber Board, Tile and Lay -in Panels 6 0.41 7 0.29 s 0.75 9 0.10 INSIDE SURFACE AIR FILM SUBTOTAL R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ ❑ ❑ El El 0.170 0.060 0.010 0.500 3.500 0.500 0.620 17.500 17.500 1.250 1.250 SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.000 0.000 0.060 0.060 0.620 0.620 17.500 17.500 1.250 1.250 0.41 0.521 0.29 0.15 0.75 0.14 0.10 0.610 0.610 20.21 20.21 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) X 2.44 0.12 0.29 0.06 0.35 0.02 1.42 0.29 0.41 0.521 0.29 0.15 0.75 0.14 0.10 5.2 TOTAL HC 1.0 "NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0495 X 0.90] + [ 0.0495 X 1 / Rc 1 - (Fr% /100)- 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 2.0 By EnregySoft User Number. 2531 Job Number. 90713 Page: 15 of 19 1 FAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 PROJECT NAME DATE Greg Norman Golf Course, Clubhouse 7/16/99 1. Watts for Illuminance Categories A -D (from below) 5,496 watts 2. Watts for Illuminance Categories E-1 (from part 2) 2,84$ watts 3. Watts for Display Lighting (from Parts 2 & 3) 70+1 + I 0 = 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) 8 344 watts uminance Categories , and U and Gross Sales Area FAA] © © a o o a 2.00 ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA orage orae ms or Warehouses ctive -Small Item Dining Bar as Floor Display Food Service—Dining - as ier isp ay_ ross Sales Floor Area D 1.11 1,355 GSA 1.11 135 Men's Employee Restrooms of e s as rooms enera C 1.86 481 omens es room of e s as rooms_ ms—General C 1.70 299 orage ressin orae ms or Warehouses_ ctive -Small Item D 1.21 264 Pro op isp ay_ ross a es oor Area GSA 1.44 1,223 as , oor isp ay isp ay_ ross Sales Floor Area GSA 1.44 122 Bag Parts D 4.55 375 BUILDING PAGE TOTAL TOTAL 4,254 5,496 > 5,218 5,496 SF WATTS EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number: 90713 Page: 16 of 19 ALLOWED LPD ALLOWED WATTS (E x F) 0.99 1,341 2.00 0.60 0.60 270 289 179 0.99 261 2.00 2,446 2.00 1.24 244 465 orage orae ms or Warehouses ctive -Small Item ALLOWED LPD ALLOWED WATTS (E x F) 0.99 1,341 2.00 0.60 0.60 270 289 179 0.99 261 2.00 2,446 2.00 1.24 244 465 i rAILORED LPD SUMMARY and WORKSHEET Part 2 of 3 LTG -4 Greg Norman Golf Course, Clubhouse 1 7/16/99 1 ® ® © M © © ® 0 0EN TASK / ACTIVITY Throw Mtg. Dist. Hgt. ALLOTTED WATTS LUMIN. CODELUMIN. TASK AREA (sf) WED ALLPDD ALLOTTED WATTS (D x E) DESIGN WATTS LUMIN. CODELUMIN. QTY. WATTS/ SIGN WATTS (H x I) ALLLOWED WATTS (Min. F or J) TOTAL AREA PUBLIC DISPLAYS I� sf PAGE TOTAL PUBLIC DISPLAY AREA X 0.1 = BUILDING TOTAL MAXIMUM AREA PUBLIC WATTS DISPLAYS (SF) EnergyPro 2.0 By EnergySoft User Number. 2531 Job Number. 90713 Page:17 of 19 S,-_.1-IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY + PROJECT NAME DATE c: Greg Norman Golf Course, Clubhouse 7/16/99 SYSTEM NAME FLOOR AREA HP -1 thru 4 & HP -7 3,620 Number of Systems 5 Heating System Output per System 58,000 Total Output (Btuh) 290,000 Output (Btuh/sgft) 80.1 Cooling System Output per System 56,000 Total Output (Btuh) I 280,000 Total Output (Tons) 23.3 Total Output (Btuh/sgft) 77.3 Total Output (sgft/Ton) 155.1 Air System CFM per System 2,000 Airflow (cfm) 10,000 Airflow (cfm/sgft) 2.76 Airflow (cfm/Ton) 428.6 Outside Air (%) 19.8 Outside Air (cfm/sgft) 0.55 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 15,496 138,719 28,81 3,796 35,766 0 6,936 1,788 0 0 1,978 79,195 -3,796 1,978 92,940 0 0 6,936 1,788 231,832 25,015 F 132,283 IER 38YCCO605 182,631 86,854 190,725 Total Adjusted System Output 182,631 86,854 190,725 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am ote: values above given at ARI conditions I I Irs ream eml 26.0 OF 61.2 OF . 79.0 OF . Outside Air 1978 cfm 69.8 of 12.0 / 77.7 of Outside Air 1978 cfm 74.6/67.8 of EnergyPro 2.0 By Energysoft Heating Coil 79.0 of Supply Air Ducts Supply Fan 78.8 of 10000 cfm ROOMS 70.0 of Return Air Ducts I 82.0 / 69.8 of 65.0 / 63.9 of 65.0 / 63.9 of - Supply Air Ducts �Y Cooling Coil Supply Fan 65.7 / 64.1 of 10000 cfm 72.3% R.H. ROOMS 74.0 ! 67.6 of Return Air Ducts User Number. 2531 Job Number: 90713 Pagel8 of 19 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE Greg Norman Golf Course, Clubhouse 7/16/99 SYSTEM NAME FLOOR AREA HP -5, 6 & 8 1,598 ENGINEERING CHECKS ISYSTEM LOAD (Number of Systems Heating System Output per System Total Output (Btuh) Output (Btuh/sqft) 3 36,000 Total Room Loads 108,000 Return Vented Lighting 67.6 Return Air Ducts Cooling System Output per System 34,200 Total Output (Btuh) 102,600 Total Output (Tons) 8.6 Total Output (Btuh/sgft) 64.2 Total Output (sgft/Ton) 186.9 Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 5,735 57,686 11,352 2,187 22,756 0 2,884 1,138 0 0 668 24,235 192 668 31,288 0 0 2,884 1,138 87,689 11,543 F77jj,320 Air System HVAC EQUIPMENT SELECTION CFM per System 1,200 Airflow (cfm) 3,600 CARRIER 38YCCO365 66,217 33,000 71,02 Airflow (cfm/sgft) 2.25 Airflow (cfm/Ton) 421.1 Outside Air (%) 18.5 Total Adjusted System Output 66,217 33,000 71,029 (Adjusted for Peak Design Conditions) _ Outside Air (cfm/sgft) 0.42 TIME OF SYSTEM PEAKJul 5 pm Jan 12 am Note: values above given at ARI conditions -1 F (Airstream Temperatures at Time of Heating ea 26.0 OF 61.6 OF 80.0 OF 80.0 OF Supply Air Ducts Outside Air 668 cfm o Heating Coil Supply Fan 79'7 F 3600 cfm ROOMS 6 70.0 OF 9.7 °F Return Air Ducts 08.6 / 76.9 OF 81.0 / 69.1 OF 63.9 / 62.8 OF 63.9 / 62.8 °F 4 Supply Air Ducts Outside Air 668 cfm Cooling Coil Supply Fan 64.6 / 63.0 OF 3600 cfm 69.9% R.H. ROOMS 74.7 ! 67.2 of 74.0 / 67.0 OF Return Air Ducts I'I EnarovPro 2-0 By EnerovSoft User Number. 2531 Job Number. 90713 Page: 19 of 19